RV EXPEDITION

RV EXPEDITION is a 1974 research vessel. The Coast Guard has recorded 16 inspections since 2016, most recently in June 2023, along with 22 deficiencies and 1 casualty investigation in 2005.

Records from 2005 to 2023. Most recent: inspection, 21 June 2023.

Built
1974
Last inspected
21 June 2023
Documentation
Expired · documentation file of 10 August 2026
Controls
None recorded without a removal date

This record may be incomplete: the most recent inspection recorded for this vessel was 3 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 23 August 2026, retrieved 5 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Research Ship class in Maury's sources begin in 2016.

Inspection record

Last inspected 21 June 2023
…with no type recorded1
Operational controls None recorded without a removal date
Years with a record 8 calendar years (2016–2023)
Every line above is a count of records the US Coast Guard wrote, or a date it recorded. A blank resolution means none was recorded in this data; it does not establish that a deficiency is outstanding. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Identity

WDD9126
Flag
UNITED STATES
Maury page id
psix-47809

Documentation record

Registered dimensions (L × B × D)85.1 ft × 21.0 ft × 8.8 ft
Registered tonnagegross 90 / net 61
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
BuilderCAMCRAFT INC · CROWN POINT, LA, UNITED STATES · built 1974
Hull materialAluminum
PropulsionDiesel Reduction
Hull shapeUNSPECIFIED
Hull configurationUNSPECIFIED
Hailing portPENSACOLA, FL
Trade endorsementsCoastwise, unrestricted
DocumentationExpired · issued 30 June 2004
Service, as the file records itResearch Vessel
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it90 - Regulatory (Subpart C or D), Gross Ton
61 - Regulatory (Subpart C or D), Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 August 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.
Vessel history report
Every record for this hull, in one document — $299

Every recorded inspection, 2016 to 2026 for this class, in one chronology · every deficiency, with system, dates and resolution · operational controls imposed and removed · every name this hull has been recorded under · the vessels it was inspected alongside, and when · how its record compares with hulls of similar age and size, as a fact about the population and never a judgement about this vessel.

Read one first, in full: a forty-year chronology · a hull that changed operators four times · the sparse case, shown as an example, not for sale.

This report is in development and is not for sale yet. There is no date, and nothing is charged. Leave an email and we will tell you when it exists, once.

Inspection history · 16

21 June 2023 Administrative Inspection · In-Service Inspection
Physical examination · Marine Safety Unit Cape Cod · USCG Northeast District (CGD-NE) · Activity 7716489
14 February 2023 In-Service Inspection
Physical examination · Marine Safety Unit Texas City · USCG Heartland District (CGD-H) · Activity 7636706
27 October 2022 Administrative Inspection · In-Service Inspection
Physical examination · Marine Safety Unit Texas City · USCG Heartland District (CGD-H) · Activity 7585044
11 April 2022 Annual Inspection
Physical examination · Marine Safety Unit Texas City · USCG Heartland District (CGD-H) · Activity 7430243
24 November 2021 Drydock Exam · Internal Structural Exam · Administrative Inspection
Physical examination · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 7357191
22 September 2021 In-Service Inspection
Physical examination · Marine Safety Unit Texas City · USCG Heartland District (CGD-H) · Activity 7318377
10 February 2021 Annual Inspection · Deficiency Check · Administrative Inspection · Internal Structural Exam
Physical examination · Marine Safety Unit Texas City · USCG Heartland District (CGD-H) · Activity 7138861
11 February 2020 COI Inspection · Internal Structural Exam
Physical examination · Marine Safety Unit Texas City · USCG Heartland District (CGD-H) · Activity 6906212
4 November 2019 Drydock Exam
Physical examination · Marine Safety Unit Texas City · USCG Heartland District (CGD-H) · Activity 6848838
3 October 2019 In-Service Inspection
Physical examination · Marine Safety Unit Texas City · USCG Heartland District (CGD-H) · Activity 6827608
31 January 2019 In-Service Inspection
Physical examination · Marine Safety Unit Texas City · USCG Heartland District (CGD-H) · Activity 6618331
26 November 2018 Deficiency Check · Annual Inspection · Internal Structural Exam
Physical examination · Marine Safety Unit Texas City · USCG Heartland District (CGD-H) · Activity 6587057
26 November 2018 Type not recorded
No type recorded · Marine Safety Unit Texas City · USCG Heartland District (CGD-H) · Activity 6587346
31 October 2017 Deficiency Check
Physical examination · Marine Safety Unit Texas City · USCG Heartland District (CGD-H) · Activity 6299049
2 October 2017 COI Inspection · Administrative Inspection · Drydock Exam
Physical examination · Marine Safety Unit Texas City · USCG Heartland District (CGD-H) · Activity 6285081
27 October 2016 Internal Structural Exam · Annual Inspection
Physical examination · Marine Safety Unit Texas City · USCG Heartland District (CGD-H) · Activity 6030916

Deficiency record · 22

02 - Structural Conditions › N/A - No Subsystem › Hull damage impairing seaworthiness
Issued 1 December 2021 Resolved
Repairs or alterations to the hull, machinery, or equipment that affect the safety of the vessel must not be made without the approval of the cognizant OCMI, except during an emergency. Vessel conducted repairs without inspectionor permission from the Coast Guard
Condition: Improper Installation
Action required: 10 - Deficiency Rectified
Due 1 December 2021
Resolved 7 January 2022
Resolution: All repairs have been made in accordance to regulations.
02 - Structural Conditions › N/A - No Subsystem › Hull damage impairing seaworthiness
Issued 24 November 2021 Resolved
A drydock examination conducted in compliance with § 176.600 must be conducted while the vessel is hauled out of the water or placed in a drydock or slipway. During the examination all accessible parts of the vessel's underwater body and all through hull fittings, including the hull plating and planking, appendages, propellers, shafts, bearings, rudders, sea chests, sea valves, and sea strainers shall be made available for examination. Sea chests, sea valves, and sea strainers must be opened for examination. Vessel was found to have holes in bottom plate, sideshell and several other wasted areas. Repairs are to be made to the satisfactory of the attending OCMI.
Condition: Damaged By Earlier Event
Action required: 17 - Rectify deficiencies prior to departure
Resolved 17 December 2021
Resolution: All repairs have been made in accordance to regulations.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 10 February 2021 Resolved
A vessel must be provided with a satisfactory arrangement for draining any watertight compartment, other than small buoyancy compartments, under all practicable conditions. Vessel is fitted with a fixed bilge system. Marine Inspectors requested a demonstration of the system forward of the collision bulkhead. vessel was unable to remove any water using the installed fixed system. Repairs are to be made to the satisfaction of a USCG Marine Inspector. 46 CFR 182.500(a)
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 11 February 2021
Resolution: Vessel was operating wrong valve. The mislabeled valve was correct and the bilge operated as normal.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Covers (hatchway-, portable-, tarpaulins, etc.)
Issued 10 February 2021 Resolved
A hatch exposed to the weather must be watertight. Marine Inspectors observed that the emergency escape scuttle leading from the accommodation space below deck up to the bulkhead deck was not able to completely lock into place. The "T" handle did not seat back into the recessed pocket. Provide a corrective action to ensure the locking mechanism works as designed. 46 CFR 179.360(a)
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 11 February 2021
Resolution: Clean hatch and now operational.
09 - Working and Living Conditions › 092 - Working Conditions › Lighting (Working spaces)
Issued 10 February 2021 Resolved
The emergency lighting required by paragraph (a) of this section must automatically actuate actuate upon failure of the main lighting system. The lamp in the steering/generator space leading to the escape hatch was non operational under both primary and back up power. Lamp is to be replaced or repair to the satisfaction of a USCG Marine Inspector. 46 CFR 183.432(b)
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 11 February 2021
Resolution: Replaced with new.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Gauges, thermometers, etc
Issued 10 February 2021 Resolved
A voltmeter and an ammeter, which can be used for measuring voltage and current of a generator that is in operation, must be provided for a generator rated at 50 volts or more. Marine Inspectors observed the gauges reading voltage while the system was secured. Repairs are to be made to the satisfaction of a USCG Marine Inspector. 46 CFR 183.320(c)
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 11 February 2021
Resolution: Replaced old gauges with new.
11 - Life Saving Appliances › N/A - No Subsystem › Stowage and provision of liferafts
Issued 10 February 2021 Resolved
The float-free link required by 180.130(a)(1) must be: (2) Of proper strength for the size of the life float or buoyant apparatus as indicated on its identification tag. Vessel had a float free link that wasn't of proper strength. Vessel rep had corrected link and replaced it to the satisfaction of the Marine Inspector 46 CFR 180.137(b)
Action required: 10 - Deficiency Rectified
Resolved 10 February 2021
Resolution: 10C
03 - Water/Weathertight Conditions › N/A - No Subsystem › Cargo & other hatchways
Issued 26 November 2018 Resolved
A hatch exposed to the weather must be watertight. Upon inpsection, the watertight hatch leading to the cargo deck from the accomodation space was reported to leak when dogged down. The engineroom hatch was also in a substandard condition. Repair accomodation and engineroom hatch covers to the satisfaction of the attending marine inspector.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 4 December 2018
Resolved 4 December 2018
10 - Safety of Navigation › N/A - No Subsystem › Charts
Issued 26 November 2018 Resolved
As appropriate for the intended voyage, a vessel must carry adequate and up-to-date charts of large enough scale to make safe navigation possible. The charts located on the navigation bridge were not up-to-date nor could they provide evidence of electronic chart updates. Replace paper charts or provide evidence of electronic chart updates.
Condition: Invalid
Action required: 50 - Rectify deficiencies w/in 30 days
Due 4 December 2018
Resolved 4 December 2018
05 - Radio Communications › N/A - No Subsystem › Other (radio communication)
Issued 26 November 2018 Resolved
Operation of transmitters of any ship station must be performed by a person holding a commercial radio operator license or permite of the class required. The vessels master was unable to produce documentation that anyone onboard had the appropriate commercial radio operator license.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 4 December 2018
Resolved 4 December 2018
01 - Certificates & Documentation › 011 - Ships Certificates › Certificate of Inspection (COI)
Issued 26 November 2018 Resolved
An inspection for renewal of a certificate of inspection is conducted to determine if the vessel is in satisfactory condition, fit for the service intended, and complies with all applicable regulations. Vessel was unable to get underway to conduct drills
Condition: Invalid
Action required: 17 - Rectify deficiencies prior to departure
Due 4 December 2018
Resolved 4 December 2018
Lifesaving › Lifefloat › Serviceable
Issued 25 October 2017 Resolved
Straps on life float rotted through. Restricted to 12 passengers.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 3 November 2017
Resolved 31 October 2017
Resolution: Replaced lifefloat.
Electrical › Electrical Distribution System (service) › Outlet Box
Issued 25 October 2017 Resolved
Numerous outlets in the kitchen, living quaters, engine room and bridge had ground faults and reverse polarity. 46 CFR 183.01-5 Old T
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 22 November 2017
Resolved 31 October 2017
Resolution: Found source of the incorrect wiring, corrected all sat.
Engineering › Compressed Air System (start air) › Valve
Issued 25 October 2017 Resolved
Relief valve on starboard air reciever could not be read. Restricted from use until proven relief valve is satisfactory relief pressure and capacity.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Resolved 31 October 2017
Resolution: replaced relief valve with a 125 psi valve.
Electrical › Lighting (emergency) › Lighting Fixture
Issued 25 October 2017 Resolved
Emgergency light in generator room non functioning.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 3 November 2017
Resolved 31 October 2017
Resolution: Replaced bulb all sat.
Fire Fighting › Fire Hoses › Condition
Issued 25 October 2017 Resolved
Stbd fire hose burst during fire drill. Replace in kind.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 3 November 2017
Resolved 31 October 2017
Resolution: Installed in fire hose, all sat.
Lifesaving › Lifebuoys › Buoyant Lifeline
Issued 27 October 2016 Resolved
Buoyant lifelines on lifebuoys located on aft deck and starboard side are wasted and unservicable. Replace lifelines on these two buoys.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 15 November 2016
Resolution: Lifelines replaced.
Communications › Alarms/Indicators › Bilge Alarm
Issued 27 October 2016 Resolved
Engine room bilge alarm not operational. Replace engine room bilge alarm.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 27 October 2016
Resolution: New bilge alarm installed/tested in presence of MIs.
Communications › Alarms/Indicators › Fire Alarm
Issued 27 October 2016 Resolved
2 smoke detectors not operational. Replace batteries and restore proper operation.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 27 October 2016
Resolution: Batteries replaced and tested successfully in the presence of MIs.
Electrical › Lighting (emergency) › Lighting Fixture
Issued 27 October 2016 Resolved
Emergency lighting in all spaces does not provide sufficient illumination so as to enable escape. Prove proper illumination to the satisfaction of the marine inspector.
Action required: 705 - Other - as specified
Due 27 November 2016
Resolved 15 November 2016
Resolution: Lighting batteries replaced and tested to the satisfaction of the attending MI.
Electrical › Electrical Distribution System (service) › Wiring
Issued 27 October 2016 Resolved
Electrical wires in machinery spaces are supported by plastic wire ties. Replace with required metal wire support.
Action required: 705 - Other - as specified
Due 27 November 2016
Resolved 15 November 2016
Resolution: Metal supports installed to satisfaction of attending MI.
Lifesaving › Lifejacket/PFD (Type I) › Lights
Issued 27 October 2016 Resolved
2 lifejackets missing lights. Affix lights. Vessel limited to 15 passengers if voyage is greater than 20 nm offshore.
Action required: 705 - Other - as specified
Due 27 November 2016
Resolved 15 November 2016
Resolution: Lights affixed.

Casualty record · 1

27 August 2005Routine · role: Involved in a Marine Casualty · serious marine incident, as classified · 1 dead · activity 2503292
Each line is an incident investigation the Coast Guard recorded with this hull among the vessels involved, with the date and the classification the Coast Guard gave it. Involvement is not fault. The investigation narrative is not published. Source: IIR, through 2026.

Recorded names · 1

SEA SEARCHER II (2005). Names as the Coast Guard recorded them in incident records, with the years they appear; some are renames and some are spelling variants.

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.