CAPTAIN FRANCES

CAPTAIN FRANCES is a 1974 passenger vessel (inspected). The Coast Guard has recorded 76 inspections since 1985, most recently in August 2026, along with 89 deficiencies.

Records from 1985 to 2026. Most recent: inspection, 8 August 2026.

Built
1974
Last inspected
8 August 2026
Documentation
Valid · documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

WDM9986
Flag
UNITED STATES
367114960, 367779990
Maury page id
psix-47833

Inspections, by type

…with no type recorded9
Years with a record 38 calendar years (1985–2026)
The 76 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Passenger Ship class in Maury's sources begin in 1977.

Documentation record

Registered dimensions (L × B × D)60.4 ft × 20.7 ft × 5.8 ft
Registered tonnagegross 68 / net 46
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
BuilderGILLIKIN CRAFT, INC · BEAUFORT, NC, UNITED STATES · built 1974
Hull materialWood
PropulsionDiesel Reduction
Hull shapeNot recorded
Hull configurationNot recorded
Hailing portPOINT JUDITH, RI
Trade endorsementsCoastwise, unrestricted, Fishery
DocumentationValid · issued 8 December 2025 · expires 31 December 2026
Service, as the file records itPassenger (Inspected)
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it68 - Regulatory (Subpart C or D), Gross Ton
46 - Regulatory (Subpart C or D), Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 September 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.

Radio station licence

WDM9986MMSI 367779990 · active · compulsorily equipped · granted 24 May 2022, expires 24 May 2032
WDJ4673MMSI 367779990 · cancelled · compulsorily equipped · granted 31 March 2017, cancelled 19 May 2022 · licensed under a name not among this hull’s recorded names (not shown)
WDJ4067MMSI 367114960 · active · compulsorily equipped · granted 22 February 2017, expires 22 February 2027 · licensed under a name not among this hull’s recorded names (not shown)
WDD2411MMSI 367114960 · expired · compulsorily equipped · granted 16 May 2006, cancelled 16 July 2016 · licensed under a name not among this hull’s recorded names (not shown)
WCW5796MMSI not assigned · expired · compulsorily equipped · granted 28 March 2000, cancelled 29 May 2010 · licensed under a name not among this hull’s recorded names (not shown)
FCC Universal Licensing System ship-station file of 6 September 2026, matched to this hull on its US Official Number. Status and dates are the file’s own. The licensee is not read from the file and is not shown. A lapsed licence’s MMSI is still the number the vessel transmitted under while it was valid.

A report is not offered for this hull: Its record holds only 2 of the seven kinds of material a report is built from: inspections, deficiencies, operational controls, tow-unit appearances, casualty records, dimensions and documentation. That is a statement about the record, not about the vessel. Reports.

Inspection history · 76

8 August 2026 Type not recorded
No type recorded · Station Point Judith · USCG Northeast District (CGD-NE) · Activity 8458475
1 June 2026 Administrative Inspection
Administrative · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 8385562
6 August 2025 Administrative Inspection · Annual Inspection
Physical examination · Marine Safety Unit Coram · USCG Northeast District (CGD-NE) · Activity 8203536
1 August 2024 Administrative Inspection · Annual Inspection · Deficiency Check
Physical examination · Marine Safety Unit Coram · USCG Northeast District (CGD-NE) · Activity 7971283
7 December 2023 Internal Structural Exam · Examination of Repairs · Drydock Exam · Administrative Inspection
Physical examination · Marine Safety Unit Coram · USCG Northeast District (CGD-NE) · Activity 7833098
29 June 2023 Deficiency Check · Annual Inspection · Administrative Inspection
Physical examination · Marine Safety Unit Coram · USCG Northeast District (CGD-NE) · Activity 7733975
24 May 2022 Re-Inspection · DAPI Audit · Deficiency Check
Physical examination · Marine Safety Unit Coram · USCG Northeast District (CGD-NE) · Activity 7452664
4 May 2022 Deficiency Check · Examination of Repairs · In-Service Inspection · Drydock Exam · Internal Structural Exam
Physical examination · Marine Safety Unit Coram · USCG Northeast District (CGD-NE) · Activity 7442451
29 June 2021 Internal Structural Exam · Annual Inspection
Physical examination · Marine Safety Unit Coram · USCG Northeast District (CGD-NE) · Activity 7237890
15 April 2021 Internal Structural Exam · Drydock Exam · Deficiency Check
Physical examination · Marine Safety Unit Coram · USCG Northeast District (CGD-NE) · Activity 7175549
1 July 2020 Annual Inspection
Physical examination · Marine Safety Unit Coram · USCG Northeast District (CGD-NE) · Activity 6994178
18 July 2019 Annual Inspection
Physical examination · Marine Safety Unit Coram · USCG Northeast District (CGD-NE) · Activity 6733021
16 January 2019 Hull Examination
Physical examination · Marine Safety Unit Coram · USCG Northeast District (CGD-NE) · Activity 6610694
24 April 2018 Annual Inspection
Physical examination · Marine Safety Unit Coram · USCG Northeast District (CGD-NE) · Activity 6381493
29 March 2018 Hull Examination · Internal Structural Exam
Physical examination · Marine Safety Unit Coram · USCG Northeast District (CGD-NE) · Activity 6375456
19 April 2017 COI Inspection
Physical examination · Marine Safety Unit Coram · USCG Northeast District (CGD-NE) · Activity 6123075
19 April 2017 COI Inspection
Physical examination · Marine Safety Unit Coram · USCG Northeast District (CGD-NE) · Activity 6133086
22 March 2017 Administrative Inspection · COI Inspection · DAPI Audit
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 6106538
8 April 2016 Internal Structural Exam · Annual Inspection · Hull Examination · Administrative Inspection
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 5861664
20 May 2014 Deficiency Check · DAPI Audit · Annual Inspection
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 4886077
2 May 2014 Internal Structural Exam · Hull Examination
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 4848678
15 February 2012 Construction Oversight
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 4244682
11 January 2012 Examination of Repairs
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 4225934
16 April 2009 Annual Inspection · Hull Examination · Examination of Repairs
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 3453237
28 April 2008 Annual Inspection · Hull Examination
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 3192053
30 March 2007 COI Inspection
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 2896612
24 May 2006 Hull Examination · Annual Inspection
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 2610230
11 May 2005 Annual Inspection
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 2353202
1 July 2004 Type not recorded
No type recorded · Station Manasquan Inlet · USCG East District (CGD-E) · Activity 2117603
26 April 2004 Hull Examination · Internal Structural Exam · Deficiency Check · Annual Inspection
Physical examination · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 2052690
5 May 2003 Annual Inspection · Deficiency Check
Physical examination · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 1786686
1 May 2002 Hull Examination
Physical examination · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 1616103
9 April 2002 COI Inspection
Physical examination · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 1603323
25 July 2001 Administrative
Administrative · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 1068833
26 February 2001 Re-Inspection
Physical examination · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 1058565
25 April 2000 Hull Examination · Re-Inspection
Physical examination · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 818235
4 October 1999 Administrative
Administrative · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 1351669
15 April 1999 COI Inspection
Physical examination · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 1122791
9 April 1999 Type not recorded
No type recorded · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 1122991
14 April 1998 Hull Examination
Physical examination · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 1123404
18 March 1998 Re-Inspection
Physical examination · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 1123403
12 May 1997 Re-Inspection
Physical examination · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 1108857
17 April 1996 COI Inspection
Physical examination · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 1080772
26 February 1996 Hull Examination
Physical examination · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 1470413
16 March 1995 COI Inspection
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 829006
1 June 1994 Hull Examination
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 872636
30 March 1994 Re-Inspection
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 869376
18 March 1993 Re-Inspection
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 836311
5 January 1993 Type not recorded
No type recorded · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 642863
16 December 1992 Type not recorded
No type recorded · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 660745
9 December 1992 Hull Examination
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 828208
23 June 1992 Type not recorded
No type recorded · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 78725
23 June 1992 Type not recorded
No type recorded · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 218697
17 March 1992 COI Inspection
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 1263910
30 May 1991 Deficiency Check
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 1234155
19 April 1991 Re-Inspection · Hull Examination
Physical examination · MSO WILMINGTON · USCG East District (CGD-E) · Activity 1221038
21 March 1991 Deficiency Check
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 996829
7 August 1990 Deficiency Check
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 1244728
24 April 1990 Re-Inspection
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 1236850
1 February 1990 Deficiency Check
Physical examination · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 1238739
26 January 1990 Hull Examination
Physical examination · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 926104
23 March 1989 COI Inspection
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 1210629
3 March 1989 Hull Examination
Physical examination · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 1197735
18 May 1988 Deficiency Check
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 897670
5 April 1988 Deficiency Check
Physical examination · MIO PHILADELPHIA · USCG East District (CGD-E) · Activity 993850
11 March 1988 Hull Examination
Physical examination · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 1297736
2 March 1988 Re-Inspection
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 1336981
10 February 1988 Deficiency Check
Physical examination · MIO PHILADELPHIA · USCG East District (CGD-E) · Activity 1327223
4 January 1988 Deficiency Check
Physical examination · MIO PHILADELPHIA · USCG East District (CGD-E) · Activity 1007691
2 September 1987 Re-Inspection
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 1008508
3 June 1987 Hull Examination
Physical examination · MIO PHILADELPHIA · USCG East District (CGD-E) · Activity 1028791
27 May 1986 Credit Drydock
Administrative · MIO PHILADELPHIA · USCG East District (CGD-E) · Activity 991405
12 March 1986 COI Inspection
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 992705
11 December 1985 Examination of Repairs
Physical examination · MIO PHILADELPHIA · USCG East District (CGD-E) · Activity 1300906
20 June 1985 Type not recorded
No type recorded · MIO PHILADELPHIA · USCG East District (CGD-E) · Activity 983545
28 March 1985 Type not recorded
No type recorded · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 979761

Deficiency record · 89

02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 6 August 2025 Resolved
Make fwd bulkhead of #2 space air and watertight.
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Due 20 August 2025
Resolved 6 August 2025
Resolution: Corrected proir to the completion of inspection.
11 - Life Saving Appliances › N/A - No Subsystem › Maintenance of Life Saving Appliances
Issued 6 August 2025 Resolved
Replace retro on L/F's as needed.
Condition: Damaged By Earlier Event
Action required: 10 - Deficiency Rectified
Due 20 August 2025
Resolved 6 August 2025
Resolution: Corrected proir to the completion of inspection.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 1 August 2024 Resolved
Laz bilge wiring was corroded and had evidently parted at some point in the past.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 31 August 2024
Resolved 1 August 2024
Resolution: Fixed by end of inspection.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 1 August 2024 Resolved
PFD stowage was not re-labeled after painting. The vessel had the placards but they were not secured anywhere.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 31 August 2024
Resolved 1 August 2024
Resolution: Secured.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 1 August 2024 Resolved
Top deck was not marked with max pax. Sign had been removed for painting at some point and not replaced.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 31 August 2024
Resolved 1 August 2024
11 - Life Saving Appliances › N/A - No Subsystem › Distress flares
Issued 29 June 2023 Resolved
Vessel is on a LBS+ route and is required 6/6 flares. Vessel only had 07. Required vessel to purchase additional flares.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 29 July 2023
Resolved 31 August 2023
Resolution: Complete
10 - Safety of Navigation › N/A - No Subsystem › Lights, shapes, sound-signals
Issued 29 June 2023 Resolved
Vessel stern light lens was missing all but the front piece which was taped in place. Issued requirement to replace lens.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 29 July 2023
Resolved 31 August 2023
Resolution: Complete.
11 - Life Saving Appliances › N/A - No Subsystem › Operational readiness of lifesaving appliances
Issued 24 May 2022 Resolved
Buoyant Apparatus needs to be labelled with the name of the vessel.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 25 June 2022
Resolved 31 May 2022
Resolution: Buoyant Apparatus is properly labelled.
05 - Radio Communications › N/A - No Subsystem › Functional requirements
Issued 24 May 2022 Resolved
Provide proof of FCC Station License and FCC Safety Radiotelephony Certificate prior to operating more than 1000' from shore with passengers.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 25 June 2022
Resolved 31 May 2022
Resolution: Received updated FCC Station License and FCC Safety Radiotelephony Certificate.
05 - Radio Communications › N/A - No Subsystem › VHF EPIRB
Issued 24 May 2022 Resolved
Provide proof of EPIRB registration prior to operating more than 3NM from shore.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 25 June 2022
Resolved 31 May 2022
Resolution: Received updated EPIRB registration.
11 - Life Saving Appliances › N/A - No Subsystem › Distress flares
Issued 29 June 2021 Resolved
Add 6 hand held flares.
Condition: Invalid
Action required: 701 - Prior to carriage of passengers/cargo
Due 29 June 2021
Resolved 29 June 2021
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 29 June 2021 Resolved
Label upper deck for maximum persons allowed.
Condition: Placed in Improper Service
Action required: 16 - Rectify deficiencies w/in 14 days
Due 10 July 2021
Resolved 29 June 2021
08 - Alarms › N/A - No Subsystem › Other (alarms)
Issued 1 July 2020 Resolved
Repair or replace bilge alarm in #2 space prior to vessel movement.
Condition: Placed in Improper Service
Action required: 17 - Rectify deficiencies prior to departure
Resolved 1 July 2020
Lifesaving › Lifefloat › Floating Electric Waterlight
Issued 20 May 2014 Resolved
The following lines were found to be weather damaged beyond serviceability: 60' throw line on life ring, float light lines on all three life floats. Renew lines to satisfaction of attending marine inspector.
Due 3 June 2014
Resolved 23 May 2014
Resolution: All lines replaced and satisfactroy.
Engineering › Fuel Oil Storage/Transfer System › Tank
Issued 11 January 2012 Resolved
Fuel tank is wasted and is being replaced. 835 issued.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Resolved 16 March 2012
Resolution: Replaced USCG letter onboard with detailed information.
Construction/Loadline › Hull › Bottom Plating
Issued 28 April 2008 Resolved
Crop and renew rotten frames port and stbd 2,3, and 4 in the engine room. Replace stbd planks 4,5,6, and 7 and port plank #7
Action required: 705 - Other - as specified
Resolved 22 May 2008
Resolution: Rotten frames and planks replaced in kind. Please see narrative to this case for details of repair.
Electrical › Electrical Distribution System (service) › Wiring
Issued 11 May 2005 Resolved
Remove dead end wiring in #4 compt.
Due 11 June 2005
Resolved 18 May 2005
Resolution: Corrected.
Electrical › Electrical Distribution System (service) › Panelboard
Issued 11 May 2005 Resolved
Install blanks in 32V and 220V panels in missing spaces.
Due 11 June 2005
Resolved 18 May 2005
Resolution: Corrected
Electrical › Lighting (emergency) › Lighting Fixture
Issued 11 May 2005 Resolved
Install shields on 32V lighting
Due 11 June 2005
Resolved 18 May 2005
Resolution: Corrected
Communications › Radio Communications › Radiotelephone Transceiver (2-4 MHz)
Issued 11 May 2005 Resolved
Prove proper operation of single sideband radio prior to carriage of px beyond 20nm.
Due 11 June 2005
Resolved 18 May 2005
Resolution: Tested, corrected
Engineering › Fuel Oil Service System › Filter
Issued 11 May 2005 Resolved
Install fire shield bowls for clear Primary fuel filter housings.
Due 11 June 2005
Resolved 18 May 2005
Resolution: Installed
Engineering › Shafting/Propeller Arrangements › Stern Tube Lubrication/Sealing
Issued 11 May 2005 Resolved
Repack shaft glands to reduce excessive leakage. Secure with double nuts once completed.
Due 11 June 2005
Resolved 18 May 2005
Resolution: Corrected
Communications › Radio Communications › EPIRB
Issued 11 May 2005 Resolved
Renew hydrostatic release for EPIRB to carriage of passengers beyond 3nm.
Due 11 June 2005
Resolved 13 May 2005
Resolution: Rcvd fax copy of hydro release reciept and recvd confirmation via phonecon that release is installed.
Documentation › Certificates/Documents › Certificate of Documentation (CG-1270)
Issued 11 May 2005 Resolved
Provide proof of vessel documentation prior to carriage of px.
Action required: 701 - Prior to carriage of passengers/cargo
Due 11 June 2005
Resolved 13 May 2005
Resolution: Rcvd fax copy of vessel current Certificate of Doc.
Lifesaving › Lifejacket/PFD (Type I) › Lights
Issued 11 May 2005 Resolved
Provide lights on all child preservers -or- request for adults only amendment.
Due 11 June 2005
Resolved 13 May 2005
Resolution: Rcvd fax request for adults only on oceans voyages.
Navigation › Piloting/Steering › Coast Guard Light List
Issued 11 May 2005 Resolved
Provide current CG lightlist
Due 11 June 2005
Resolved 18 May 2005
Resolution: Corrected
Construction/Loadline › Hull
Issued 26 April 2004 Resolved
Repair wood rot in keel bottom as marked. LEGACY COMPONENT DESC: Keel
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 11 May 2004
Construction/Loadline › Hull
Issued 26 April 2004 Resolved
Renew or sister knees #3, 7, 13, 14 on STBD side of Engine Room. LEGACY COMPONENT DESC: Bracket
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 11 May 2004
Construction/Loadline › Hull
Issued 26 April 2004 Resolved
Grind/sand to good wood inner planking in way of frames 8-9 and 11-12 in Engine Room as marked. LEGACY COMPONENT DESC: Bottom Plating
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 11 May 2004
Construction/Loadline › Hull
Issued 26 April 2004 Resolved
Grind/sand to good wood and preserve all marked areas in Engine Room. LEGACY COMPONENT DESC: Side Shell
Due 6 June 2004
Resolved 11 May 2004
Construction/Loadline › Hull
Issued 26 April 2004 Resolved
Conduct post drydock underway checkride in the presence of an attending MI.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 11 May 2004
Construction/Loadline › Structures
Issued 26 April 2004 Resolved
Renew battery box supports on stbd side of engine room. LEGACY COMPONENT DESC: Superstructure
Due 6 June 2004
Resolved 11 May 2004
Construction/Loadline › Hull
Issued 26 April 2004 Resolved
Repair frame #5 portside in engine room. LEGACY COMPONENT DESC: Transverse Frame
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 11 May 2004
Operations/Management › Drug and Alcohol Testing › Proof of Enrollment
Issued 5 May 2003 Resolved
Provide durrent Drug Testing program participation letter.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 6 May 2003
Documentation › Certificates/Documents › Certificate of Documentation (CG-1270)
Issued 5 May 2003 Resolved
Provide proof of vessel documentation.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 6 May 2003
Communications › Radio Communications › EPIRB
Issued 5 May 2003 Resolved
Renew hydrostatic release for EPIRB.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 9 May 2003
Lifesaving › Buoyant Apparatus
Issued 5 May 2003 Resolved
Renew retro-reflective tape on upper life float. LEGACY COMPONENT DESC: Retro-reflective tape
Due 5 June 2003
Resolved 9 May 2003
Communications › Alarms/Indicators › Bilge Alarm
Issued 5 May 2003 Resolved
Prove proper operation of all bilge high-level alarms and pump switches.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 9 May 2003
Accommodation/Occupational Safety › Potable Water System › Piping
Issued 5 May 2003 Resolved
Cap open pipe in deck drain piping in Lazzarette.
Due 5 June 2003
Resolved 5 June 2003
Engineering › Fuel Oil Storage/Transfer System › Valve
Issued 5 May 2003 Resolved
Renew STBD emergency fuel shut-off handle.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 5 June 2003
Engineering › Fuel Oil Service System › Valve
Issued 5 May 2003 Resolved
Repair F/O leak on auxiliary generator.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 9 May 2003
Engineering › Bilge Water Management System › Manifold
Issued 5 May 2003 Resolved
Label bilge piping manifold.
Due 5 June 2003
Resolved 5 June 2003
Documentation › Certificates/Documents
Issued 9 April 2002 Resolved
Vessel not to carry passengers for hire beyond 30 April, 2002 until a credit drydock exam has been conducted to the satisfaction of the attending marine inspector.
Due 30 April 2002
Resolved 1 May 2002
Resolution: Conducted credit dry dock exam all sat. Granted 24 month credit.
Construction/Loadline
Issued 25 April 2000 Resolved
REPLACE BILGE OVERBOARD VALVE IN FORPEAK.
Condition: Unknown
Due 11 May 2000
Resolved 11 May 2000
Construction/Loadline
Issued 25 April 2000 Resolved
CROP AND RENEW WORM SHOE IN MARKED AREAS.
Condition: Unknown
Due 11 May 2000
Resolved 11 May 2000
Construction/Loadline
Issued 25 April 2000 Resolved
GUAGE AND FILL MARKED AREA PORT SIDE AFT OF KEEL.
Condition: Unknown
Due 11 May 2000
Resolved 11 May 2000
Construction/Loadline
Issued 25 April 2000 Resolved
REMOVE ROTTED SECTION OF FRAME IN LAZARETTE IN WAY OF STBD SIDE AFT, INNER STRUT BOLT. DRY AND TREAT FRAME AND FIT BACKING PLATE FOR TWO AFT STRUT BOLTS.
Condition: Unknown
Due 11 May 2000
Resolved 11 May 2000
Lifesaving
Issued 25 April 2000 Resolved
VESSEL MAY NOT CARRY PASSENGERS MORE THAN 20 MILES FROM A HARBOR OF SAFE REFUGE UNTIL SUITABLE LIFE JACKET LIGHTS ARE PROVIDED.
Condition: Unknown
Due 30 June 2000
Resolved 1 May 2002
Construction/Loadline
Issued 25 April 2000 Resolved
REPLACE GASKET IN FORPEAK THRU-DECK HATCH AND MAKE DOGS FREE.
Condition: Unknown
Due 11 May 2000
Resolved 11 May 2000
Fire Fighting
Issued 9 April 1999 Resolved
PROVIDE PROOF OF SATISFACTORY HYDROSTATIC TEST OF CO2 FLEX HOSES.
Condition: Unknown
Due 21 April 1999
Resolved 21 April 1999
Construction/Loadline
Issued 26 February 1996 Resolved
PRIOR TO OPERATING WITH PASSENGERS, PRESENT VESSEL FOR UNDERWAY EXAMINATIONTO THE SATISFACTION OF COGNIZANT OCMI.
Condition: Unknown
Due 26 February 1996
Resolved 26 February 1996
Documentation
Issued 18 March 1993 Resolved
[withheld — contains personal information; the deficiency system, dates, and resolution status are shown above]
Condition: Unknown
Due 18 March 1993
Resolved 18 March 1993
Navigation
Issued 19 April 1991 Resolved
VESSEL CANNOT OPERATE OVER 20 MILES UNTIL RADIO CHECK CONDUCTED ON SSB- 2182_x001C_
Condition: Unknown
Due 19 April 1991
Resolved 19 April 1991
Lifesaving
Issued 19 April 1991 Resolved
VESSEL IS RESTRICTED TO CARRIAGE OF 66 TOTAL PERSONS ON OCEAN ROUTE._x001C_ _x001C_ _x001C_ _x001C_
Condition: Unknown
Due 19 April 1991
Resolved 19 April 1991
Navigation
Issued 19 April 1991 Resolved
VESSEL CANNOT OPERATE OVER 20 MILES UNTIL EPIRB TESTED.
Condition: Unknown
Due 19 April 1991
Resolved 19 April 1991
Navigation
Issued 24 April 1990 Resolved
PROVIDE 1990 EDITION OF LIGHT LIST ON BOARD VESSEL
Condition: Unknown
Due 24 April 1990
Resolved 24 April 1990
Electrical
Issued 24 April 1990 Resolved
PROVIDE COVERS FOR ALL BATTERY BOXES
Condition: Unknown
Due 24 April 1990
Resolved 24 April 1990
Documentation
Issued 24 April 1990 Resolved
PROVIDE CERTIFICATION THAT VESSEL EMPLOYER HAS INSTITUTED PRE-EMPLOYMENT/ POST CASUALTY DRUG TESTING PROGRAM
Condition: Unknown
Due 24 April 1990
Resolved 24 April 1990
Construction/Loadline
Issued 24 April 1990 Resolved
REPAIR SMALL GAPS BETWEEN DECK AND SIDE SHELL IN AFT COMPARTMENT
Condition: Unknown
Due 24 April 1990
Resolved 24 April 1990
Construction/Loadline
Issued 24 April 1990 Resolved
REPLACE WET ROTTED SIDE SHELL PLANK IN BOW COMPARTMENT, STBD BETWEEN FRAMES3 & 4
Condition: Unknown
Due 24 April 1990
Resolved 24 April 1990
Construction/Loadline
Issued 24 April 1990 Resolved
REPAIR STEADY LEAK AT STEM/KNEE AREA
Condition: Unknown
Due 24 April 1990
Resolved 24 April 1990
Unknown
Issued 1 February 1990 Resolved
D1. HOSE TEST FORWARD AND AFT HATCHES TO PROVE WATERTIGHT INTEGRITY TO THE SATISFACTION OF THE ATTENDING CG MARINE INSPECTOR AT MSO BALMS.
Condition: Unknown
Due 1 February 1990
Resolved 1 February 1990
Unknown
Issued 1 February 1990 Resolved
D2. REPAIR DAMAGED RUBRAIL ON PORT AND STBD SIDES.
Condition: Unknown
Due 1 February 1990
Resolved 1 February 1990
Unknown
Issued 26 January 1990 Resolved
D1. REPAIR ALL OPEN SEAMS AT BUTTS, STEM, AND KEEL IAW NVIC 1-63 AND GOOD MARINE PRACTICE.
Condition: Unknown
Due 26 January 1990
Resolved 26 January 1990
Unknown
Issued 26 January 1990 Resolved
D2. REPLACE PLANK ON STBD SIDE AT GARBOARD STRAKE COVERING AT LEAST 6 FRAMESPACES AND NO SHORTER THAN 5 FT. IAW NVIC 1-63.
Condition: Unknown
Due 26 January 1990
Resolved 26 January 1990
Unknown
Issued 26 January 1990 Resolved
D3. REPLACE 2 OF THE 4 RUBBER CUTLASS BEARINGS ON THE AFT STRUTS.
Condition: Unknown
Due 26 January 1990
Resolved 26 January 1990
Unknown
Issued 26 January 1990 Resolved
D4. REPAIR HOLE ON BOTTOM ABOVE STBD RUDDER IAW NVIC 1-63 AND GOOD MARINE PRACTICE.
Condition: Unknown
Due 26 January 1990
Resolved 26 January 1990
Unknown
Issued 26 January 1990 Resolved
D5. REPACK AND MAKE WT PORT AND STBD RUDDER STOCKS.
Condition: Unknown
Due 26 January 1990
Resolved 26 January 1990
Unknown
Issued 26 January 1990 Resolved
D6. SEAL HOLES AT FASTENERS ON BOTTOM STBD SIDE ABOVE RUDDER.
Condition: Unknown
Due 26 January 1990
Resolved 26 January 1990
Unknown
Issued 26 January 1990 Resolved
D7. REMOVE ALL ROTTEN WOOD AT STEM BELOW THE MAIN DECK AND MAKE THE DECK WATERTIGHT AT THE INTERSECTION OF THE MAIN DECK AND THE STEM.
Condition: Unknown
Due 26 January 1990
Resolved 26 January 1990
Unknown
Issued 26 January 1990 Resolved
D8. REPLACE ALL WASTED PLYWOOD ON PORT AND STBD SIDES AT BULWARKS.
Condition: Unknown
Due 26 January 1990
Resolved 26 January 1990
Unknown
Issued 26 January 1990 Resolved
D9. MAKE WATERTIGHT ALL DECK SEAMS WHERE LEAKING AND PROVE TO CG MARINE INSPECTOR WITH HOSE TEST.
Condition: Unknown
Due 26 January 1990
Resolved 26 January 1990
Unknown
Issued 26 January 1990 Resolved
D10. REMOVE ALL ROTTEN WOOD AT AFT WATERTIGHT BULKHEAD AND MAKE WATERTIGHT.
Condition: Unknown
Due 26 January 1990
Resolved 26 January 1990
Unknown
Issued 26 January 1990 Resolved
D11. REMOVE ALL FOREIGN DEBRIS FROM BILGES, LEDGES, AND AREAS WHERE MOISTURE CAN BE TRAPPED IN ORDER TO PREVENT ACCELERATION OF WET ROT.
Condition: Unknown
Due 26 January 1990
Resolved 26 January 1990
Unknown
Issued 26 January 1990 Resolved
D12. FIX LEAK AT DECK ON STERN AT PORT AND STBD CORNER POSTS TO MAKE WATER-TIGHT AND PROVE TO CG MARINE INSPECTOR WITH HOSE TEST.
Condition: Unknown
Due 26 January 1990
Resolved 26 January 1990
Electrical
Issued 23 March 1989 Resolved
REPLACE ALL SOLID CONDUCTOR ROMEXWIRING
Condition: Unknown
Due 23 March 1989
Resolved 23 March 1989
Electrical
Issued 23 March 1989 Resolved
PRIVIDE ACID RESISTANT TRAY FOR 12 VOLT BATTERY
Condition: Unknown
Due 23 March 1989
Resolved 23 March 1989
Deck/Cargo
Issued 2 March 1988 Resolved
PROVIDE AN OPERATIONAL TEST OF THE METALLIC BILGE LINE SYSTEM AND FIRE MAINSYSTEM.
Condition: Unknown
Due 2 March 1988
Resolved 2 March 1988
Engineering
Issued 2 March 1988 Resolved
PROVIDE AN OPERATIONAL ENGINE TEST.
Condition: Unknown
Due 2 March 1988
Resolved 2 March 1988
Unknown
Issued 2 March 1988 Resolved
REMOVE LOOSE ELECTRICAL CABLE TO UNUSED WASH--DOWN PUMP IN THE FUEL TANK COMPARTMENT.
Condition: Unknown
Due 2 March 1988
Resolved 2 March 1988
Construction/Loadline
Issued 3 June 1987 Resolved
SET IN DRIFT PINS TO THE KEEL STRONGBACK MEMBER WHERE ORIGINAL PINS HAVE WASTED. THE LOCATION(S) ARE THE #1 PIN IN THE FORWARDMOST COMPARTMENT AND THE #1 AND #2 PINS IN THE ROD SPACE.
Condition: Unknown
Due 3 June 1987
Resolved 3 June 1987
Construction/Loadline
Issued 3 June 1987 Resolved
SCRAPE THEN TREAT THE WET ROT ON THE UPPER STEM MEMBER (PORT AND STARBOARD)PRIOR TO 30 JUNE 1987. THIS AREA IS LOCATED IN THE FORWARDMOST COMPARTMENT.
Condition: Unknown
Due 3 June 1987
Resolved 3 June 1987
Construction/Loadline
Issued 3 June 1987 Resolved
FREE UP THE OPEN DECK SCUTTLE DOGGING MEMBERS PRIOR TO 30 JUNE 1987.
Condition: Unknown
Due 3 June 1987
Resolved 3 June 1987
Construction/Loadline
Issued 3 June 1987 Resolved
PROVIDE CAPTIVE CHAINS OR LINES FOR THE TWO (2) EXPOSED DECK SCUTTLE COVERSAS REQUIRED BY 46CFR 171.024, PRIOR TO 30 JUNE 1987.
Condition: Unknown
Due 3 June 1987
Resolved 3 June 1987
Construction/Loadline
Issued 3 June 1987 Resolved
RENEW THE WASTED NUTS ON THE FIRST TWO (2) KEEL FASTENERS IN THE FOREPEAK PRIOR TO 30 JUNE 1987.
Condition: Unknown
Due 3 June 1987
Resolved 3 June 1987
Electrical
Issued 3 June 1987 Resolved
PROVIDE BLANK COVERS OVER THE OPEN ELECTRICAL PANEL ACCESSES WHERE THE CIRCUIT BREAKERS HAVE BEEN REMOVED. THIS PANEL IS LOCATED IN WAY OF THE LADDER TO THE ROD SPACE. THIS IS TO BE COMPLETED PRIOR TO 30 JUNE 1987.
Condition: Unknown
Due 3 June 1987
Resolved 3 June 1987
Construction/Loadline
Issued 3 June 1987 Resolved
PROVIDE ADDITIONAL FASTENERS IN WAY OF THE #3 PORT BRACKET WHERE SPLIT. THIS IS LOCATED IN THE FORWARDMOST COMPARTMENT IN WAY OF THE CHINE.
Condition: Unknown
Due 3 June 1987
Resolved 3 June 1987
Construction/Loadline
Issued 20 June 1985 Resolved
MAKE PERMANENT REPAIR IN WAY OF WORM HOLE DAMAGE IN STRAKE PORT SIDE APPROX 8 FEET FROM STEM.
Condition: Unknown
Due 20 June 1985
Resolved 20 June 1985
Construction/Loadline
Issued 20 June 1985 Resolved
RENEW ROTTEN PORTION OF STBD SUPPORT POST IN ENGINE ROOM.
Condition: Unknown
Due 20 June 1985
Resolved 20 June 1985

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.