MAURY USCG vessel records
← All vessels

BLUE DOLPHIN

Built
1998
Last inspected
24 November 2025
Documentation
Valid · NVDC file of 10 August 2026
Controls
None recorded without a removal date

Coast Guard record current through 23 August 2026, retrieved 5 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Passenger Ship class in Maury's sources begin in 2016.

Inspection record

Last inspected 24 November 2025
Operational controls None recorded without a removal date
Years with a record 10 calendar years (2016–2025)
Every line above is a count of records the US Coast Guard wrote, or a date it recorded. A blank resolution means none was recorded in this data; it does not establish that a deficiency is outstanding. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Identity

WDM7373
478331
Flag
UNITED STATES
Maury page id
psix-478331

Documentation record

Registered dimensions (L × B × D)51.0 ft × 16.0 ft × 3.0 ft
Registered tonnagegross 34 / net 27
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
BuilderSUSQUEHANNA SANTEE BTWKS INC · WILLOW STREET, PA, UNITED STATES · built 1998
Hull materialAluminum
PropulsionGasoline Outboard
Hull shapeShip
Hull configurationTwin Hull
Hailing portORANGE BEACH, AL
Endorsements, as the file codes themcw_un, rec
DocumentationValid · issued 14 March 2026 · expires 31 March 2027
Service, as the file records itPassenger (Inspected)
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it34 - Simplified, Gross Ton
27 - Simplified, Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 August 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.
Professional
The full record for this vessel

Behind this panel: 17 inspections, each with its date, unit and type; 24 deficiencies with the resolution recorded against each; operational controls, none recorded without a removal date; no tow-unit appearances recorded; no other recorded names; the documentation record: dimensions, tonnage, builder, hailing port and endorsements. Every line is a record the Coast Guard wrote; the counts above are the same counts as in the summary, and they are free.

Professional is $39 a month or $299 a year, or $19.99 a month locked for life at the founding rate, for the first 200 subscribers. It unlocks every detail section on every vessel page, fleet watch tied to your account, and ownership records on request. Already a subscriber? Sign in.

Maury does not score, rate or grade vessels, at any price.

Vessel history report

A report is not offered for this hull. Its record holds only 2 of the seven kinds of material a report is built from: inspections, deficiencies, operational controls, tow-unit appearances, casualty records, dimensions and documentation. That is a statement about the record, not about the vessel. What a sparse-record report looks like.

Inspection history · 17

24 November 2025 Annual Inspection · Deficiency Check · Administrative Inspection
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 8273231
26 November 2024 Annual Inspection · Administrative Inspection
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 8040396
9 September 2024 Administrative Inspection · Drydock Exam
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 7999365
8 January 2024 Administrative Inspection · Annual Inspection
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 7846474
9 February 2023 Administrative Inspection · Annual Inspection
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 7620874
26 September 2022 Internal Structural Exam · Drydock Exam
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 7566639
8 December 2021 Deficiency Check · Annual Inspection · Administrative Inspection
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 7364805
2 August 2021 In-Service Inspection · Administrative Inspection
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 7275171
23 December 2020 Administrative Inspection · DAPI Audit · Annual Inspection
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 7115517
25 August 2020 Administrative Inspection · Drydock Exam
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 7042438
8 November 2019 Administrative Inspection · COI Inspection
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 6852160
4 December 2018 Annual Inspection · Internal Structural Exam · Administrative Inspection
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 6591729
6 August 2018 Drydock Exam · Administrative Inspection
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 6502984
20 October 2017 Administrative Inspection · Deficiency Check · Annual Inspection
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 6291868
6 January 2017 Deficiency Check · Administrative Inspection
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 6067894
15 November 2016 Administrative Inspection · Annual Inspection · DAPI Audit
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 6041847
11 August 2016 Hull Examination · Administrative Inspection · Internal Structural Exam · Examination of Repairs
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 5969248

Deficiency record · 24

13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 24 November 2025 Resolved
The discharge ends of fuel tank vent pipes must be fitted with removable flame screens or flame arresters. The flame screens must consist of a single screen of corrosion resistant wire of at least 30 × 30 mesh. Observed both flame screens on port and starboard fuel tanks to be corroded.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 3 February 2026
Resolved 3 February 2026
Resolution: Flame screens were replaced on the fuel tanks
11 - Life Saving Appliances › N/A - No Subsystem › Evaluation, testing and approval
Issued 24 November 2025 Resolved
A vessel must carry one floating waterlight, unless it is limited to daytime operation, in which case no floating waterlight is required. Each floating waterlight must be approved in accordance with §161.010 in subchapter Q of this chapter. Observed ring buoy without an approved waterlight.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 3 February 2026
Resolved 3 February 2026
Resolution: A new light was acquired that met regulations
09 - Working and Living Conditions › 091 - Living Conditions › Medical Equipment
Issued 9 February 2023 Resolved
A vessel must carry either a first-aid kit that meets the requirements in 46 CFR 199.175(b)(10) or a kit with equivalent contents and instructions. Burn gel, inhalants, and aspirin were expired. 46 CFR 184.710
Action required: 16 - Rectify deficiencies w/in 14 days
Due 23 February 2023
Resolved 22 February 2023
Resolution: Vessel rep sent picture of non-expired burn gel, inhalants, and aspirin.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 9 February 2023 Resolved
A vessel must carry one floating waterlight. The batteries in the floating waterlight were expired. 46 CFR 180.70(d)
Action required: 16 - Rectify deficiencies w/in 14 days
Due 23 February 2023
Resolved 22 February 2023
Resolution: Vessel rep sent picture of non-expired battery
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 9 February 2023 Resolved
Machinery, equipment, materials, and arrangements not covered by standards in this subchapter may be inspected in accordance with standards acceptable to the cognizant OCMI as good marine practice. Dead end wires were located on starboard stern as well as starboard bow above the operating station. 46 CFR 176.800(a)
Action required: 16 - Rectify deficiencies w/in 14 days
Due 23 February 2023
Resolved 22 February 2023
Resolution: Vessel rep sent picture of area with wires removed.
07 - Fire Safety › N/A - No Subsystem › Maintenance of Fire protection systems
Issued 9 February 2023 Resolved
Portable and semi-portable extinguishers must be inspected and maintained in accordance with NFPA 10. Monthly inspections required by NFPA 10 may be conducted by the owner, operator, person-in-charge, or a designated member of the crew. Vessel did not have proof of monthly inspections for their portable fire extinguishers. 46 CFR 176.810(b)(1)(ii)
Action required: 16 - Rectify deficiencies w/in 14 days
Due 23 February 2023
Resolved 13 March 2023
Resolution: Received picture of new fire extinguisher log.
05 - Radio Communications › N/A - No Subsystem › VHF radio installation
Issued 12 January 2022 Resolved
Vessel must comply with applicable requirements for any radio installations IAW 47CFR80. MMSI number issued by FCC must be properly entered into VHF radio.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 26 January 2022
Resolved 26 January 2022
Resolution: New VHF radio installed with proper MMSI number entered.
07 - Fire Safety › N/A - No Subsystem › Remote Means of control (opening,pumps,ventilation,etc.) Machinery spaces
Issued 23 December 2020 Resolved
Vessel must have suitable emergency fuel shut off valves to secure fuel flow to the engine in the event of an emergency. Found port engine fuel shut off valve handle deteriorated and broken. Replace handle or valve assembly.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 26 February 2021
Resolution: Submitted photos of new handle.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 5 December 2019 Resolved
Found cracked fuel hose on fuel line for diesel generator from priming bulb to filter.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Resolved 19 December 2019
Resolution: Recieved pictures, All satisfactory
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 8 November 2019 Resolved
Found Hyrdraulis Steering leak at the helm.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Resolved 19 December 2019
Resolution: Recieved pictures, all satisfactory
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 20 February 2019 Resolved
Replace worn retro-reflective type 1 material on seven child-size lifejackets.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 6 March 2019
Resolved 4 March 2019
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 20 February 2019 Resolved
Install new battery cover on missing aft battery box.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 6 March 2019
Resolved 4 March 2019
11 - Life Saving Appliances › N/A - No Subsystem › Other (life saving)
Issued 20 February 2019 Resolved
Replace two expired ammonia inhalants and three eye flush dressing packs. Add twelve safety pins to first aid kit; Or obtain coast guard approved first aid kit.
Condition: Invalid
Action required: 16 - Rectify deficiencies w/in 14 days
Due 6 March 2019
Resolved 4 March 2019
Accommodation/Occupational Safety › Occupational Safety › Tripping/Falling Hazard
Issued 11 January 2018 Resolved
KB01 Secure Juice Machine IAW 46 CFR 184.220
Action required: 705 - Other - as specified
Due 11 February 2018
Resolved 6 February 2018
Resolution: Added straps to secure.
Fire Fighting › Portable CO2 Fire Extinguisher › Discharge Hose/Tube
Issued 11 January 2018 Resolved
KB02 Renew portable CO2 hose for extinguisher in closet 46 CFR 181.500(a).
Action required: 705 - Other - as specified
Due 11 February 2018
Resolved 6 February 2018
Resolution: Replaced hose.
Communications › Radio Communications › VHF Radiotelephone
Issued 11 January 2018 Resolved
KB03 Program MMSI # into VHF-FM radio IAW 46 CFR 184.502 and 47 CFR 80
Action required: 705 - Other - as specified
Due 11 February 2018
Resolved 6 February 2018
Resolution: Entered MMSI number.
Lifesaving › Lifejacket/PFD (General) › Storage
Issued 11 January 2018 Resolved
KB04 Separate/Label Child life jackets IAW 46 CFR 180.78(a)(5).
Action required: 705 - Other - as specified
Due 11 February 2018
Resolved 6 February 2018
Resolution: Corrected labeling.
Electrical › Electrical Distribution System (service) › Circuit Breaker
Issued 11 January 2018 Resolved
KB05 Properly install CD mixer breaker to the satisfaction of attending MI 46CFR 183.200(b).
Action required: 705 - Other - as specified
Due 11 February 2018
Resolved 6 February 2018
Resolution: Placed switch into a junction box.
Electrical › Electric Supply System (service) › Battery Charger
Issued 11 January 2018 Resolved
KB06 Install Ammeter for battery charger 46 CFR 183.350(f)
Action required: 705 - Other - as specified
Due 11 February 2018
Resolved 9 February 2018
Resolution: Owner/operator emailed picture of installed ammeter.
Accommodation/Occupational Safety › Medical/First Aid › Medicine Chest
Issued 15 December 2016 Resolved
Burn gel in first aid kit is expired. Provide new burn gel. 46 CFR 183.420
Condition: Invalid
Action required: 705 - Other - as specified
Due 15 January 2017
Resolved 6 January 2017
Resolution: Documentation attesting to the purchase of burn gel sent by owner.
Navigation › Collision/Grounding Avoidance › Navigation Lights
Issued 15 December 2016 Resolved
All around light is inoperable. Fix or replace light. 46 CFR 183.420
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 15 January 2017
Resolved 6 January 2017
Resolution: Verified nav lights are operable.
Navigation › Piloting/Steering › Marine Charts
Issued 15 December 2016 Resolved
Vessel's navigation chart not current and corrected. Provide current and corrected chart for area of intended operation. 46 CFR 184.420
Condition: Invalid
Action required: 705 - Other - as specified
Due 15 January 2017
Resolved 6 January 2017
Resolution: Updated chart on board provided by owner.
Navigation › Piloting/Steering › Inland Navigation Rules
Issued 15 December 2016 Resolved
Vessel's copy of navrules is outdated. Provide current copy of navrules. 33 CFR 83.01
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 15 January 2017
Resolved 6 January 2017
Resolution: Owner provided current copy of navrules.
Construction/Loadline › Markings › Vessel Name/Home Port
Issued 15 December 2016 Resolved
Vessel's name not clearly marked on bow. Mark vessel IAW 46 CFR 67.123
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 15 January 2017
Resolved 6 January 2017
Resolution: Vsl owner painted vsl name on bow.

Ownership record