MAURY USCG vessel records Sign in
← All vessels

THULE PHOENIX

THULE PHOENIX is a 1974 mobile offshore drilling unit. The Coast Guard has recorded 39 inspections since 1981, most recently in December 2010, along with 59 deficiencies.

Records from 1981 to 2010. Most recent: inspection, 14 December 2010.

Built
1974
Last inspected
14 December 2010
Documentation
Not in the documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

WZG7133
Flag
LIBERIA
—
Maury page id
psix-47850

Inspections, by type

…with no type recorded27
Years with a record 11 calendar years (1981–2010)
The 39 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

This record may be incomplete: the most recent inspection recorded for this vessel was 16 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Offshore class in Maury's sources begin in 1978.

Documentation record

Tonnage as PSIX records it4295 - Regulatory (Subpart C or D), Gross Ton
8058 - Convention (Subpart B), Gross Ton
4295 - Regulatory (Subpart C or D), Net Ton
2417 - Convention (Subpart B), Net Ton
This hull's Official Number is not in the NVDC file dated 10 September 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.

Radio station licence

No FCC ship-station licence is recorded against this Official Number in the file of 6 September 2026. That is a fact about the licence file, not about the radio.

A report is not offered for this hull: Its record holds only 2 of the seven kinds of material a report is built from: inspections, deficiencies, operational controls, tow-unit appearances, casualty records, dimensions and documentation. That is a statement about the record, not about the vessel. Reports.

Inspection history · 39

14 December 2010 In-Service Inspection
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 3910571
30 March 2001 Permit to Proceed
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1461375
13 October 1989 Administrative
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1349492
12 December 1988 Deficiency Check
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1342515
17 November 1988 Re-Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 898878
30 December 1987 Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1008750
3 November 1987 Hull Examination · COI Inspection
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1334415
9 October 1987 Permit to Proceed
Administrative · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1018109
20 April 1987 Administrative
Administrative · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1019253
10 October 1986 Type not recorded
No type recorded · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1012048
15 May 1986 Type not recorded
No type recorded · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1295854
8 April 1986 Type not recorded
No type recorded · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1294861
24 March 1986 Type not recorded
No type recorded · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 990939
20 February 1986 COI Inspection
Physical examination · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 999857
14 January 1986 Type not recorded
No type recorded · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1303617
28 September 1985 Deficiency Check
Physical examination · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 991537
26 September 1985 Deficiency Check
Physical examination · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1306039
24 July 1985 Type not recorded
No type recorded · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 1291977
19 April 1985 Type not recorded
No type recorded · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1288901
29 March 1985 Type not recorded
No type recorded · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 981420
17 January 1985 Type not recorded
No type recorded · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 978083
7 January 1985 Credit Drydock
Administrative · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1306041
17 December 1984 Type not recorded
No type recorded · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 980760
15 November 1984 Type not recorded
No type recorded · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1286866
23 October 1984 Type not recorded
No type recorded · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1282140
26 July 1984 Type not recorded
No type recorded · MSO Mobile · USCG Heartland District (CGD-H) · Activity 977358
15 June 1984 Type not recorded
No type recorded · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 974632
21 March 1984 Type not recorded
No type recorded · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1280319
13 March 1984 Type not recorded
No type recorded · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1281063
27 February 1984 Type not recorded
No type recorded · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1280452
2 November 1983 Type not recorded
No type recorded · MSO Mobile · USCG Heartland District (CGD-H) · Activity 970187
21 September 1983 Type not recorded
No type recorded · MSO Mobile · USCG Heartland District (CGD-H) · Activity 970360
21 July 1983 Type not recorded
No type recorded · MSO Mobile · USCG Heartland District (CGD-H) · Activity 971997
28 June 1983 Type not recorded
No type recorded · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 966848
5 May 1983 Type not recorded
No type recorded · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 964710
22 March 1983 Type not recorded
No type recorded · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 969164
29 July 1982 Type not recorded
No type recorded · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 1272174
15 March 1982 Type not recorded
No type recorded · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 1281656
6 March 1981 Type not recorded
No type recorded · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 1278833

Deficiency record · 59

Unknown
Issued 17 November 1988 Resolved
PROVIDE ANNUAL CRANE EXAMINATION REPORT PRIOR TO REACTIVATION OF RIG.
Condition: Unknown
Due 3 November 1989
Resolved 18 May 2002
Resolution: MISLE Maintenance - Resolved all open deficiencies issued prior to 6/1/1997 where activity was closed and deficiency due date was past
Unknown
Issued 17 November 1988 Resolved
DEMONSTRATE THE PROPER OPERATION OF ALL REMOTE SHUTDOWNS FOR FUEL OIL, VENTILATION AND TRANSFER PUMPS.
Condition: Unknown
Due 3 November 1989
Resolved 18 May 2002
Resolution: MISLE Maintenance - Resolved all open deficiencies issued prior to 6/1/1997 where activity was closed and deficiency due date was past
Accommodation/Occupational Safety
Issued 17 November 1988 Resolved
SHOW PROPER OPERATION OF THE SANITARY WATER, POTABLE WATER SYSTEMS.
Condition: Unknown
Due 3 November 1989
Resolved 18 May 2002
Resolution: MISLE Maintenance - Resolved all open deficiencies issued prior to 6/1/1997 where activity was closed and deficiency due date was past
Fire Fighting
Issued 17 November 1988 Resolved
SHOW PROPER OPERATION OF THE BILGE AND FIRE MAIN SYSTEMS.
Condition: Unknown
Due 3 November 1989
Resolved 18 May 2002
Resolution: MISLE Maintenance - Resolved all open deficiencies issued prior to 6/1/1997 where activity was closed and deficiency due date was past
Electrical
Issued 17 November 1988 Resolved
DEMONSTRATE PROPER OPERATION OF REVERSE POWER RELAYS AND REVERSE CURRENT.
Condition: Unknown
Due 3 November 1989
Resolved 18 May 2002
Resolution: MISLE Maintenance - Resolved all open deficiencies issued prior to 6/1/1997 where activity was closed and deficiency due date was past
Fire Fighting
Issued 17 November 1988 Resolved
HYDROSTATICLY TEST ALL FIRE HOSES.
Condition: Unknown
Due 3 November 1989
Resolved 18 May 2002
Resolution: MISLE Maintenance - Resolved all open deficiencies issued prior to 6/1/1997 where activity was closed and deficiency due date was past
Fire Fighting
Issued 17 November 1988 Resolved
SERVICE ALL HAND AND SEMI PORTABLE FIRE EXTINGUSHERS.
Condition: Unknown
Due 3 November 1989
Resolved 18 May 2002
Resolution: MISLE Maintenance - Resolved all open deficiencies issued prior to 6/1/1997 where activity was closed and deficiency due date was past
Electrical
Issued 17 November 1988 Resolved
PROVIDE MEGGER READINGS FOR GENERATOR WINDINGS, DC METERS AND OTHER PRIMARYSYSTEMS.
Condition: Unknown
Due 3 November 1989
Resolved 18 May 2002
Resolution: MISLE Maintenance - Resolved all open deficiencies issued prior to 6/1/1997 where activity was closed and deficiency due date was past
Unknown
Issued 17 November 1988 Resolved
RENEW HAND FLARES IN BOAT #3 PRIOR TO REACTIVATION OF RIG.
Condition: Unknown
Due 3 November 1989
Resolved 18 May 2002
Resolution: MISLE Maintenance - Resolved all open deficiencies issued prior to 6/1/1997 where activity was closed and deficiency due date was past
Unknown
Issued 17 November 1988 Resolved
PROVE OPERATION OF ENGINE #2 BOAT PRIOR TO REACTIVATION OF RIG.
Condition: Unknown
Due 3 November 1989
Resolved 18 May 2002
Resolution: MISLE Maintenance - Resolved all open deficiencies issued prior to 6/1/1997 where activity was closed and deficiency due date was past
Unknown
Issued 17 November 1988 Resolved
ENSURE ALL LOW VELOCITY FIRE APPLICATORS ARE OUTFITTED WITH NON-CLOGGING TIPS PRIOR TO REACTIVATION OF RIG.
Condition: Unknown
Due 3 November 1989
Resolved 18 May 2002
Resolution: MISLE Maintenance - Resolved all open deficiencies issued prior to 6/1/1997 where activity was closed and deficiency due date was past
Construction/Loadline
Issued 17 November 1988 Resolved
DEMONSTRATE THE PROPER OPERATION OF ALL REMOTE CONTROLLED BALLAST SYSTEM VALVES, PUMPS AND CONTROL CENTER.
Condition: Unknown
Due 3 November 1989
Resolved 18 May 2002
Resolution: MISLE Maintenance - Resolved all open deficiencies issued prior to 6/1/1997 where activity was closed and deficiency due date was past
Unknown
Issued 17 November 1988 Resolved
DEMONSTRATE THE PROPER OPERATION OF THE COMPRESSED AIR SYSTEM.
Condition: Unknown
Due 3 November 1989
Resolved 18 May 2002
Resolution: MISLE Maintenance - Resolved all open deficiencies issued prior to 6/1/1997 where activity was closed and deficiency due date was past
Unknown
Issued 17 November 1988 Resolved
DEMONSTRATE THE PROPER OPERATION OF THE REFRIGERATION AND AIR CONDITIONING SYSTEM.
Condition: Unknown
Due 3 November 1989
Resolved 18 May 2002
Resolution: MISLE Maintenance - Resolved all open deficiencies issued prior to 6/1/1997 where activity was closed and deficiency due date was past
Unknown
Issued 17 November 1988 Resolved
DEMONSTRATE THE PROPER OPERATION OF THE MUD PUMP RELIEF VALVES.
Condition: Unknown
Due 3 November 1989
Resolved 18 May 2002
Resolution: MISLE Maintenance - Resolved all open deficiencies issued prior to 6/1/1997 where activity was closed and deficiency due date was past
Electrical
Issued 17 November 1988 Resolved
REPLACE THE POWER DISTRIBUTION PANEL IN THE SACK ROOM.
Condition: Unknown
Due 3 November 1989
Resolved 18 May 2002
Resolution: MISLE Maintenance - Resolved all open deficiencies issued prior to 6/1/1997 where activity was closed and deficiency due date was past
Electrical
Issued 17 November 1988 Resolved
PRIOR TO OPERATION, TEST ALL PURGE ALARMS ON DRILL FLOOR AND MUD PIT AREAS.
Condition: Unknown
Due 3 November 1989
Resolved 18 May 2002
Resolution: MISLE Maintenance - Resolved all open deficiencies issued prior to 6/1/1997 where activity was closed and deficiency due date was past
Electrical
Issued 17 November 1988 Resolved
PRIOR TO DRILLING, ENSURE ALL NON-EXPLOSION PROOF JUNCTION BOXES ARE PURGEDIN ALL HAZARDOUS AREA.
Condition: Unknown
Due 3 November 1989
Resolved 18 May 2002
Resolution: MISLE Maintenance - Resolved all open deficiencies issued prior to 6/1/1997 where activity was closed and deficiency due date was past
Electrical
Issued 17 November 1988 Resolved
PRIOR TO OPERATION, ENSURE ALL BOLTS MISSING FROM EXPLOSION PROOF JUNCTION BOXES ARE IN PLACE.
Condition: Unknown
Due 3 November 1989
Resolved 18 May 2002
Resolution: MISLE Maintenance - Resolved all open deficiencies issued prior to 6/1/1997 where activity was closed and deficiency due date was past
Electrical
Issued 17 November 1988 Resolved
PRIOR TO OPERATION, ENSURE ALL SCREW CAP EXPLOSION PROOF JUNCTION BOX COVERS ARE TIGHTENED IN ALL HAZARDOUS AREAS.
Condition: Unknown
Due 3 November 1989
Resolved 18 May 2002
Resolution: MISLE Maintenance - Resolved all open deficiencies issued prior to 6/1/1997 where activity was closed and deficiency due date was past
Electrical
Issued 17 November 1988 Resolved
PRIOR TO OPERATION, ENSURE ALL EYS FITTINGS ARE SECURE.
Condition: Unknown
Due 3 November 1989
Resolved 18 May 2002
Resolution: MISLE Maintenance - Resolved all open deficiencies issued prior to 6/1/1997 where activity was closed and deficiency due date was past
Electrical
Issued 17 November 1988 Resolved
REMOVE ALL SO CABLE FROM RIG (OR PRIOR TO OPERATIONS).
Condition: Unknown
Due 3 November 1989
Resolved 18 May 2002
Resolution: MISLE Maintenance - Resolved all open deficiencies issued prior to 6/1/1997 where activity was closed and deficiency due date was past
Electrical
Issued 17 November 1988 Resolved
ENSURE ALL ELECTRICAL FITTINGS ON DRILL FLOOR ARE APPROVED FOR HAZARDOUS LOCATIONS (OR PRIOR TO DRILLING).
Condition: Unknown
Due 3 November 1989
Resolved 18 May 2002
Resolution: MISLE Maintenance - Resolved all open deficiencies issued prior to 6/1/1997 where activity was closed and deficiency due date was past
Electrical
Issued 17 November 1988 Resolved
REMOVE ALL DEAD END WIRING ON DRILL FLOOR AND MUD PITS.
Condition: Unknown
Due 3 November 1989
Resolved 18 May 2002
Resolution: MISLE Maintenance - Resolved all open deficiencies issued prior to 6/1/1997 where activity was closed and deficiency due date was past
Electrical
Issued 17 November 1988 Resolved
MOUNT PROPERLY ALL EXPLOSION PROOF JUNCTION BOXES ON DRILL FLOOR, SHAKER AREA AND MUD PITS.
Condition: Unknown
Due 3 November 1989
Resolved 18 May 2002
Resolution: MISLE Maintenance - Resolved all open deficiencies issued prior to 6/1/1997 where activity was closed and deficiency due date was past
Electrical
Issued 17 November 1988 Resolved
PRIOR TO OPERATION, REPLACE CABLE HANGERS ON REAR OF DRILL FLOOR OVERHEAD. HANGERS ARE WASTED.
Condition: Unknown
Due 3 November 1989
Resolved 18 May 2002
Resolution: MISLE Maintenance - Resolved all open deficiencies issued prior to 6/1/1997 where activity was closed and deficiency due date was past
Electrical
Issued 17 November 1988 Resolved
REMOVE OR REPLACE EXPLOSION PROOF JUNCTION BOX PORT SIDE AFT DRILL FLOOR. RECEPTACLE IS SEVERLY WASTED (OR PRIOR TO OPERATION).
Condition: Unknown
Due 3 November 1989
Resolved 18 May 2002
Resolution: MISLE Maintenance - Resolved all open deficiencies issued prior to 6/1/1997 where activity was closed and deficiency due date was past
Electrical
Issued 17 November 1988 Resolved
PRIOR TO OPERATION, REPLACE BRAID ON EXPOSED WIRING TO DRIVE MOTORS ON SHALE SHAKERS.
Condition: Unknown
Due 3 November 1989
Resolved 18 May 2002
Resolution: MISLE Maintenance - Resolved all open deficiencies issued prior to 6/1/1997 where activity was closed and deficiency due date was past
Electrical
Issued 17 November 1988 Resolved
PRIOR TO DRILLING, PROVIDE PROPER EXPLOSION PROOF JUNCTION BOX FOR WIRING IMPROPERLY SPLICED IN MUD PITS.
Condition: Unknown
Due 3 November 1989
Resolved 18 May 2002
Resolution: MISLE Maintenance - Resolved all open deficiencies issued prior to 6/1/1997 where activity was closed and deficiency due date was past
Electrical
Issued 17 November 1988 Resolved
PRIOR TO DRILLING, PROVIDE PROPER FITTING FOR CABLE PENETRATIONS IN MUD PITS.
Condition: Unknown
Due 3 November 1989
Resolved 18 May 2002
Resolution: MISLE Maintenance - Resolved all open deficiencies issued prior to 6/1/1997 where activity was closed and deficiency due date was past
Electrical
Issued 17 November 1988 Resolved
PRIOR TO DRILLING (OPERATION) REPLACE GENERAL ALARM IN MUD PITS WITH APPROVED TYPE FOR CLASS I DIVISION II AREA.
Condition: Unknown
Due 3 November 1989
Resolved 18 May 2002
Resolution: MISLE Maintenance - Resolved all open deficiencies issued prior to 6/1/1997 where activity was closed and deficiency due date was past
Unknown
Issued 17 November 1988 Resolved
PROVE OPERATION OF ALL LIFE BOAT LAUCHING AND RETRIEVED SYSTEMS PRIOR TO REACTIVATION OF RIG.
Condition: Unknown
Due 3 November 1989
Resolved 18 May 2002
Resolution: MISLE Maintenance - Resolved all open deficiencies issued prior to 6/1/1997 where activity was closed and deficiency due date was past
Unknown
Issued 17 November 1988 Resolved
PROVIDE CURRENT CERTIFICATE OF FINANCIAL RESPONSIBILITY PRIOR TO REACTIVATION OF RIG.
Condition: Unknown
Due 17 November 1988
Resolved 17 November 1988
Navigation
Issued 17 November 1988 Resolved
ARTIFICIAL ISLAND (OBSTRUCTION) LIGHTS NEED TO FLASH IN UNISON. CHECK FOCAL PLANE ADJUSTMENTS ON ALL LIGHTS.
Condition: Unknown
Due 17 November 1988
Resolved 17 November 1988
Unknown
Issued 17 November 1988 Resolved
PROVE OPERATION OF GENERAL ALARM SYSTEM PRIOR TO REACTIVATION OF RIG.
Condition: Unknown
Due 17 November 1988
Resolved 17 November 1988
Unknown
Issued 17 November 1988 Resolved
ENSURE APPROPRIATE TYPE AND NUMBERS OF FIRE FIGHTING AND LIFESAVING EQUIPMENT ARE PROPERLY LOCATED PRIOR TO REACTIVATION OF RIG.
Condition: Unknown
Due 17 November 1988
Resolved 17 November 1988
Unknown
Issued 17 November 1988 Resolved
ENSURE PROPER OPERATION OF ALL HELO DECK LIGHTING PRIOR TO OPERATION OF RIG.
Condition: Unknown
Due 3 November 1989
Resolved 18 May 2002
Resolution: MISLE Maintenance - Resolved all open deficiencies issued prior to 6/1/1997 where activity was closed and deficiency due date was past
Unknown
Issued 17 November 1988 Resolved
REINSTALL ALL MISSING RIG LADDERS PRIOR TO REACTIVATION OF RIG.
Condition: Unknown
Due 3 November 1989
Resolved 18 May 2002
Resolution: MISLE Maintenance - Resolved all open deficiencies issued prior to 6/1/1997 where activity was closed and deficiency due date was past
Unknown
Issued 17 November 1988 Resolved
PROVIDE CURRENT LIFE RAFT SERVICING CERTIFICATES PRIOR TO REACTIVATION OF RIG.
Condition: Unknown
Due 17 November 1988
Resolved 17 November 1988
Unknown
Issued 17 November 1988 Resolved
RESUBMIT VESSEL OPERATION MANUAL TO G-MSC AS REQUIRED BY 46 CFR 109.121.
Condition: Unknown
Due 3 November 1989
Resolved 18 May 2002
Resolution: MISLE Maintenance - Resolved all open deficiencies issued prior to 6/1/1997 where activity was closed and deficiency due date was past
Electrical
Issued 17 November 1988 Resolved
DEMONSTRATE PROPER OPERATION OF ALL GENERATOR DIESELS, OVERSPEED, LOW LUBE SHUTDOWN AND HIGH TEMP SHUTDOWN.
Condition: Unknown
Due 3 November 1989
Resolved 18 May 2002
Resolution: MISLE Maintenance - Resolved all open deficiencies issued prior to 6/1/1997 where activity was closed and deficiency due date was past
Deck/Cargo
Issued 3 November 1987 Resolved
REPLACE GLASS ON STBD CRANE.
Condition: Unknown
Due 3 November 1987
Resolved 3 November 1987
Documentation
Issued 3 November 1987 Resolved
CONDUCT A FIRE AND BOAT DRILL TO BE COMPLETED PRIOR TO 03DEC87.
Condition: Unknown
Due 3 November 1987
Resolved 3 November 1987
Lifesaving
Issued 9 October 1987 Resolved
MAKE TWO MEANS OF EMBARKATION AVAILABLE FOR RIG ABANDONMENT (I.E. EITHER REPLACE MISSING FIXED LADDERS ON COLUMNS OR INSTALL APPROVED SCRAMBLE NETS.)
Condition: Unknown
Due 9 October 1987
Resolved 9 October 1987
Fire Fighting
Issued 20 February 1986 Resolved
REPAIR INOPERATIVE GENERAL ALARM IN THE STARBOARD PUMP ROOM.
Condition: Unknown
Due 20 February 1986
Resolved 20 February 1986
Accommodation/Occupational Safety
Issued 20 February 1986 Resolved
PROVE SATISFACTORY OPERATION OF THE VENTILATION SHUTDOWN FOR THE STANDBY GENERATOR ROOM LOCATED OUTSIDE THE SPACE ADJACENT TO THE MOON POOL AREA.
Condition: Unknown
Due 20 February 1986
Resolved 20 February 1986
Accommodation/Occupational Safety
Issued 20 February 1986 Resolved
MAKE AVAILABLE FOR INTERNAL INSPECTION ALL AIR RECEIVERS, BULK TANKS AND TENSIONER BOTTLES PRIOR TO COMMENCING NEXT RIG MOVE.
Condition: Unknown
Due 20 February 1986
Resolved 20 February 1986
Deck/Cargo
Issued 20 February 1986 Resolved
BENCH TEST ALL RELIEF VALVES ON THE AIR RECEIVERS, BULK TANKS AND TENSIONERBOTTLES.
Condition: Unknown
Due 20 February 1986
Resolved 20 February 1986
Lifesaving
Issued 20 February 1986 Resolved
REMOVE NON APPROVED SCRAMBLE NETS OR PROVIDE EVIDENCE THAT THESE NETS ARE APPROVED.
Condition: Unknown
Due 20 February 1986
Resolved 20 February 1986
Fire Fighting
Issued 20 February 1986 Resolved
REPLACE DETERIORATED BOX W/GLASS OVER MACHINERY SPACE VENTILATION SHUTDOWN LOCATED OUTSIDE THE STANDBY GENERATOR ROOM. (CELLAR DECK AREA).
Condition: Unknown
Due 20 February 1986
Resolved 20 February 1986
Accommodation/Occupational Safety
Issued 20 February 1986 Resolved
PROVE SATISFACTORY OPERATION OF ALL REMOTE VENTILATION SHUTDOWNS FOR ACCOMODATIONS AND MACHINERY SPACE.
Condition: Unknown
Due 20 February 1986
Resolved 20 February 1986
Deck/Cargo
Issued 28 September 1985 Resolved
PROVIDE (2) ASME APPROVED RELIEF VALVES FOR BULK TANKS 46 CFR PART 54
Condition: Unknown
Due 28 September 1985
Resolved 28 September 1985
Documentation
Issued 26 July 1984 Resolved
SUBMIT FOR APPROVAL THE DRAWINGS FOR THE NEWLY INSTALLED RISER TENSIONER & MOTION COMPENSATOR PIPING SYS ALONG WITH A SAFETY ANALYSIS OF SAME SYS.
Condition: Unknown
Due 26 July 1984
Resolved 26 July 1984
Documentation
Issued 26 July 1984 Resolved
SUBMIT FOR APPROVAL THE OP MANUAL TO INCLUDE ALL CHANGES ACCOMPLISHED AT INGALLS SHIPBLDG. PASCAG. [name withheld] 05JUN84 THRU 25JUN84 WHICH AFFECT SAME.
Condition: Unknown
Due 26 July 1984
Resolved 26 July 1984
Fire Fighting
Issued 13 March 1984 Resolved
CONTINUE WIRING OF GENERAL ALARM LIGHT IN GENERATOR SPACE AND BELLS AT EACHANCHOR WINDLASS CONTROL TEST IN PRESENCE OF MARINE INSPECTOR. 46CFR113.25
Condition: Unknown
Due 13 March 1984
Resolved 13 March 1984
Lifesaving
Issued 13 March 1984 Resolved
COMPLETE INSTALLATION OF MOTOR CONTROLLER FOR NUMBER TWO (2) CAPSULE TEST IN PRESSENCE OF MARINE INSPECTOR. 46CFR111.95
Condition: Unknown
Due 13 March 1984
Resolved 13 March 1984
Fire Fighting
Issued 13 March 1984 Resolved
COMPLETE HYDRO SERVICING OF FIXED CO2 SYSTEM FOR GENERATOR SPACE AND RESTORE SYSTEM TO FULL CAPABILITES. 46CFR108.431
Condition: Unknown
Due 13 March 1984
Resolved 13 March 1984
Lifesaving
Issued 13 March 1984 Resolved
REPLACE RATIONS IN NUMBERS TWO (2) AND FOUR (4) CAPSULES TO COMPLY WITH OCEANS ROUTE. 46CFR111.95
Condition: Unknown
Due 13 March 1984
Resolved 13 March 1984
Construction/Loadline
Issued 21 July 1983 Resolved
CG-835 ITEM 1 DTD 21JUL83 - CROP AND RENEW TO ORIGINAL SCANTLINGS THE SET-IN AREA IN WAY OF THE 56FT WATER LEVEL OF THE P-2 COLUMN.
Condition: Unknown
Due 21 July 1983
Resolved 21 July 1983

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.