Records from 1998 to 2009. Most recent: inspection, 16 March 2009.
A report is not offered for this hull: Its record holds only 2 of the seven kinds of material a report is built from: inspections, deficiencies, operational controls, tow-unit appearances, casualty records, dimensions and documentation. That is a statement about the record, not about the vessel. Reports.
Inspection history · 18
16 March 2009
Administrative Inspection
Administrative · Sector Boston · USCG Northeast District (CGD-NE) · Activity 3434215
10 July 2008
Administrative Inspection
Administrative · Sector Boston · USCG Northeast District (CGD-NE) · Activity 3263235
21 March 2008
Examination of Repairs · Annual Inspection
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 3168995
5 December 2007
Deficiency Check · Hull Examination · In-Service Inspection · Internal Structural Exam
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 3110470
6 February 2007
COI Inspection · Hull Examination
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 2867911
13 September 2006
Damage Survey
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 2778405
15 March 2006
Re-Inspection · Deficiency Check
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 2602779
22 March 2005
Re-Inspection
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 2316275
2 November 2004
Deficiency Check
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 2234007
23 March 2004
Re-Inspection · Hull Examination
Physical examination · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 2030598
13 March 2003
Re-Inspection
Physical examination · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 1756370
20 March 2002
COI Inspection
Physical examination · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 1495340
15 March 2001
Re-Inspection
Physical examination · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 1406891
13 September 2000
Damage Survey
Physical examination · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 1395537
7 May 2000
Hull Examination · Re-Inspection
Physical examination · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 1464936
5 August 1999
Type not recorded
No type recorded · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 775230
23 March 1999
COI Inspection
Physical examination · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 1110892
1 July 1998
COI Inspection · Hull Examination
Physical examination · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 1128689
Documentation › Manuals/Policy Documentation › Emergency Instructions
Issued 21 March 2008
Resolved
Renew illegible Emergency Broadcast Placard
Action required: 705 - Other - as specified
Due 21 March 2008
Resolved 26 March 2008
Resolution: Corrected
Fire Fighting › Portable Dry Chemical Fire Extinguisher › Service
Issued 21 March 2008
Resolved
Aft, stbd portable extinguisher overdue for service.
Action required: 705 - Other - as specified
Due 21 March 2008
Resolved 26 March 2008
Resolution: Corrected
Stability › Watertight Integrity › Weathertight Enclosure
Issued 21 March 2008
Resolved
Make forward compartment hatch cover watertight.
Action required: 705 - Other - as specified
Due 21 March 2008
Resolved 26 March 2008
Resolution: Corrected
Engineering › Gasoline Engine (propulsion) › Valve Cover (4 cycle)
Issued 21 March 2008
Resolved
Repair valve cover leak
Action required: 705 - Other - as specified
Due 21 March 2008
Resolved 26 March 2008
Resolution: Corrected
Fire Fighting › Fixed Fire Detection System › Heat Detectors
Issued 21 March 2008
Resolved
Forward heat detector mount broken/loose.
Action required: 705 - Other - as specified
Due 21 March 2008
Resolved 26 March 2008
Resolution: Corrected
Construction/Loadline › Hull › Hull Plating
Issued 21 March 2008
Resolved
Wastage/hole in way of propellor shaft tube hull penetration.
Action required: 701 - Prior to carriage of passengers/cargo
Due 21 March 2008
Resolved 26 March 2008
Resolution: Corrected
Construction/Loadline › Hull › Hull Plating
Issued 21 March 2008
Resolved
Wasted/leaking plate at bottom of aft bilge compartment, stbd side. Crop and renew area at turn into tunnel.
Action required: 701 - Prior to carriage of passengers/cargo
Due 21 March 2008
Resolved 24 March 2008
Resolution: Corrected
Lifesaving › Lifebuoys › Buoyant Lifeline
Issued 15 March 2006
Resolved
Replace wasted lifebuoy lifeline.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 31 March 2006
Resolved 17 March 2006
Resolution: Lifeline replaced.
Lifesaving › Lifebuoys › Self-igniting Lights
Issued 15 March 2006
Resolved
Replace the damaged lifebuoy floatlight on the stern.
Condition: Damaged By Earlier Event
Action required: 705 - Other - as specified
Due 31 March 2006
Resolved 17 March 2006
Resolution: Floatlight replaced.
Engineering › Steering Gear System › Rudder
Issued 15 March 2006
Resolved
Rudder not operating properly (unable to swing from port to starboard), repair and prove propper operation.
Condition: Unknown
Action required: 701 - Prior to carriage of passengers/cargo
Due 31 March 2006
Resolved 20 March 2006
Resolution: Rudder repaired and a satisfactory test was conducted.
Fire Fighting › Fixed Fire Detection System › Detector/Call Point Grouping
Issued 2 November 2004
Resolved
Prior to operating prove proper operation of vapor detector.
Action required: 701 - Prior to carriage of passengers/cargo
Due 30 April 2005
Resolved 4 November 2004
Engineering › Fuel Oil Storage/Transfer System › Valve
Issued 2 November 2004
Resolved
Provide access to fuel tank cutout valve and label both fuel cutout valves.
Action required: 701 - Prior to carriage of passengers/cargo
Due 30 April 2005
Resolved 4 November 2004
Operations/Management › Drills/Instruction › Man Overboard Recovery
Issued 2 November 2004
Resolved
Proir to operating in the 2005 season conduct drills with CG inspector.
Action required: 701 - Prior to carriage of passengers/cargo
Due 30 April 2005
Resolved 22 March 2005
Resolution: Conducted underway man overboard drills.
Fire Fighting › Fixed CO2 Fire Extinguishing System › Servicing
Issued 2 November 2004
Resolved
Prior to March 2005 perform annual service on fire fighting systems.
Action required: 705 - Other - as specified
Due 1 March 2005
Resolved 22 March 2005
Resolution: Wittnessed annual service tags.
Construction/Loadline › Hull › Strut/Cross Tie
Issued 2 November 2004
Resolved
Prior to 2005 season crop and renew horizontal angles in prop tunnel for secondary prop strut mounts.
Action required: 705 - Other - as specified
Due 30 April 2005
Resolved 22 March 2005
Resolution: Examined new horizontal angles.
Engineering › Bilge Water Management System
Issued 13 March 2003
Resolved
Prove proper operation of bilge pumps, bilge high water alarms and flammable vapor detection systems. LEGACY COMPONENT DESC: Pump
Action required: 701 - Prior to carriage of passengers/cargo
Due 13 April 2003
Resolved 19 March 2003
Resolution: Witnessed satisfactory test of bilge pumps, bilge alarms and flammable vapor detectors.
Construction/Loadline › Hull
Issued 13 March 2003
Resolved
Prior to carrying passengers, make permanent repairs to weld fracture in in way of prop tunnel, port side. LEGACY COMPONENT DESC: Hull Plating
Action required: 701 - Prior to carriage of passengers/cargo
Due 13 April 2003
Resolved 19 March 2003
Resolution: Examined and witnessed satisfactory hydro test of weld repair.
Lifesaving › Lifejacket/PFD (Type I)
Issued 13 March 2003
Resolved
Provide additional adult Type I PFD for a total of 34. Until cleared vessel is restricted to 33 total persons. LEGACY COMPONENT DESC: Quantity
Condition: Unknown
Action required: 705 - Other - as specified
Due 13 April 2003
Resolved 19 March 2003
Resolution: Examined and found satisfactory 34 adult PFDs.
Accommodation/Occupational Safety › Medical/First Aid
Issued 20 March 2002
Resolved
Renew all expired items if first aid kit NLT 01APR02.
Action required: 705 - Other - as specified
Due 1 April 2002
Resolved 26 March 2002
Engineering
Issued 20 March 2002
Resolved
Test bilge pumps and high level alarms prior to carrying passengers.
Action required: 705 - Other - as specified
Due 1 April 2002
Resolved 26 March 2002
Engineering
Issued 20 March 2002
Resolved
Test vapor detection system prior to carrying passengers.
Action required: 705 - Other - as specified
Due 1 April 2002
Resolved 26 March 2002
Accommodation/Occupational Safety › Other Accommodation Spaces
Issued 20 March 2002
Resolved
Properly repair emergency escapes for both sides to fall clear when cable is pulled prior to carrying passengers.
Action required: 705 - Other - as specified
Due 1 April 2002
Resolved 26 March 2002
Construction/Loadline › Hull › Hull Plating
Issued 20 March 2002
Resolved
Properly repair pin holes in steering compartment stbd side sheer line prior to carrying passengers.
Action required: 705 - Other - as specified
Due 1 April 2002
Resolved 26 March 2002
Construction/Loadline
Issued 23 March 1999
Resolved
REPAIR PIN HOLE LEAK IN FORWARD END OF REAR WHEEL WELL, PORT SIDE.
Condition: Unknown
Due 31 March 1999
Resolved 31 March 1999