Records from 1981 to 2010. Most recent: inspection, 4 November 2010.
Inspection history · 92
4 November 2010
Annual Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 3884284
10 February 2009
Internal Structural Exam · Examination of Repairs · Hull Examination · Periodic Inspection
Physical examination · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 3415239
14 October 2008
Commercial Dive Inspection · Administrative Inspection · Damage Survey · Deficiency Check · MTSA Verification · Periodic Inspection · Examination of Repairs
Physical examination · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 3345060
8 November 2007
Re-Inspection · Commercial Dive Inspection · Deficiency Check
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 3095129
1 June 2007
Damage Survey · Examination of Repairs
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 2977618
9 January 2007
In-Service Inspection · Deficiency Check
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 2853048
5 January 2007
Type not recorded
No type recorded · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 2854927
1 August 2006
COI Inspection · MTSA Verification · Internal Structural Exam · Hull Examination
Physical examination · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 2732616
22 February 2005
Re-Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 2294740
9 September 2004
MTSA Verification
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 2191554
10 December 2003
Re-Inspection · Examination of Repairs · Hull Examination
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1961690
14 April 2003
Re-Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1771173
8 July 2002
Type not recorded
No type recorded · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1702219
7 March 2002
Re-Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1491462
10 May 2001
COI Inspection · Hull Examination
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1379378
11 March 2001
Type not recorded
No type recorded · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 33149
24 October 2000
Type not recorded
No type recorded · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 214647
23 August 2000
Damage Survey · Examination of Repairs
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1054503
15 March 2000
Re-Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1435009
28 April 1999
Type not recorded
No type recorded · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 215222
15 March 1999
COI Inspection · Hull Examination
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1404712
11 May 1998
Re-Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1452390
10 March 1998
Examination of Repairs
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1409853
5 March 1998
Type not recorded
No type recorded · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 127501
28 October 1997
Type not recorded
No type recorded · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 75568
4 April 1997
COI Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1460071
31 March 1996
Hull Examination
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1357532
6 February 1996
COI Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1380415
23 May 1995
Type not recorded
No type recorded · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 707983
22 March 1995
Examination of Repairs · Damage Survey · Re-Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1442217
15 February 1995
Type not recorded
No type recorded · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 19818
3 November 1994
Type not recorded
No type recorded · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 186292
12 September 1994
Type not recorded
No type recorded · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 158948
23 August 1994
Deficiency Check
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 861321
18 July 1994
Deficiency Check
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 869792
24 June 1994
Administrative
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1023926
18 May 1994
Deficiency Check
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 859397
18 February 1994
COI Inspection · Hull Examination
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1473605
30 March 1993
Re-Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1461505
21 February 1993
Type not recorded
No type recorded · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 216085
4 November 1992
Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 354256
15 September 1992
Damage Survey · Examination of Repairs
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1463741
9 September 1992
Type not recorded
No type recorded · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 646385
20 August 1992
Type not recorded
No type recorded · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 8579
9 August 1992
Type not recorded
No type recorded · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 88659
4 July 1992
Type not recorded
No type recorded · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 102934
29 June 1992
Type not recorded
No type recorded · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 55870
11 June 1992
Type not recorded
No type recorded · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 91579
9 June 1992
Type not recorded
No type recorded · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 80890
4 June 1992
Type not recorded
No type recorded · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 102507
30 May 1992
Type not recorded
No type recorded · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 176632
8 May 1992
Type not recorded
No type recorded · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 951522
27 April 1992
Administrative
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 953138
21 April 1992
Examination of Repairs
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1452895
3 February 1992
COI Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1005626
4 December 1991
Type not recorded
No type recorded · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 483261
24 November 1991
Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 152184
21 October 1991
Initial Construction-Excluding Oversight
Physical examination · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 1246979
6 April 1991
Type not recorded
No type recorded · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 504854
8 February 1991
Re-Inspection · Hull Examination
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 923036
19 December 1990
Examination of Repairs · Damage Survey
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1211003
23 November 1990
Type not recorded
No type recorded · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 498171
31 August 1990
Type not recorded
No type recorded · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 524357
15 August 1990
Type not recorded
No type recorded · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 531331
13 April 1990
Type not recorded
No type recorded · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 498530
8 March 1990
Deficiency Check
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 931245
8 February 1990
COI Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1225834
10 September 1989
Type not recorded
No type recorded · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 513826
25 May 1989
Deficiency Check
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1343507
24 May 1989
Type not recorded
No type recorded · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 491294
5 May 1989
Type not recorded
No type recorded · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 438387
3 May 1989
Type not recorded
No type recorded · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 517801
2 May 1989
Type not recorded
No type recorded · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1346882
13 April 1989
Type not recorded
No type recorded · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 535975
31 March 1989
Re-Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1036555
22 November 1988
Hull Examination
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1207166
27 June 1988
Examination of Repairs
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1208984
15 March 1988
Deficiency Check
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1302010
12 February 1988
COI Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1025874
30 March 1987
Re-Inspection
Physical examination · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1332168
20 March 1987
Administrative
Administrative · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1017756
9 December 1986
Administrative
Administrative · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1334099
11 March 1986
Type not recorded
No type recorded · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 999416
7 February 1986
COI Inspection · Credit Drydock
Physical examination · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1307839
8 March 1985
Type not recorded
No type recorded · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 980949
7 February 1985
Type not recorded
No type recorded · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 981463
6 July 1984
Type not recorded
No type recorded · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 974401
24 June 1984
Type not recorded
No type recorded · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1280763
5 March 1984
Type not recorded
No type recorded · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1281193
7 November 1983
Type not recorded
No type recorded · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 971824
3 February 1983
Type not recorded
No type recorded · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 971970
20 January 1981
Type not recorded
No type recorded · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1281575
Communications › Alarms/Indicators › Engineers' Assistance-needed Alarm
Issued 4 November 2010
Resolved
Provide Engineers [name withheld] or Sound Powered Phone in Engineers stateroom.
Action required: 705 - Other - as specified
Due 3 December 2010
Resolved 22 February 2011
Resolution: Engineers [name withheld] installed in Engineers stateroom
Deck/Cargo › Marine Portable Tanks › Valve/Fitting Guard
Issued 4 November 2010
Resolved
Provide fire fighting and safety equipment as applicable for MPT and DOT tanks
Action required: 705 - Other - as specified
Due 3 December 2010
Resolved 22 February 2011
Resolution: Additional Fire Fighting equipment only required when vsl is carrying MPT or DOT tanks.
Navigation › Emergency Steering › Communications to Emergency Steering
Issued 4 November 2010
Resolved
Clean off emergency instructions placard for emergency steering.
Action required: 705 - Other - as specified
Due 3 December 2010
Resolved 22 February 2011
Resolution: Placard cleaned.
Engineering › Reduction Gearing/Clutches › Shaft
Issued 4 November 2010
Resolved
Double nut both Stbd and Port Tailshafts
Action required: 705 - Other - as specified
Due 3 December 2010
Resolved 22 February 2011
Resolution: Both Port and Stbd tailshafts double nutted.
Engineering › Reduction Gearing/Clutches › Shaft
Issued 4 November 2010
Resolved
Secure excessive leak Stbd Tailshaft.
Action required: 705 - Other - as specified
Due 3 December 2010
Resolved 22 February 2011
Resolution: Tailshaft gland adjusted for water flow.
Lifesaving › Lifebuoys › Markings (ship name/port)
Issued 4 November 2010
Resolved
Properly stencil all liferings.
Action required: 705 - Other - as specified
Due 3 December 2010
Resolved 22 February 2011
Resolution: Completed.
Pollution Prevention/Response › Prevention Equipment › Oily Water Separator (15 ppm)
Issued 4 November 2010
Resolved
Demonstrate proper operation of Oily Water Seperator at next inspection by Marine Inspector.
Action required: 705 - Other - as specified
Due 3 December 2010
Resolved 22 February 2011
Resolution: 3rd party certification of proper operation of OWS by Green Marine Services.
Communications › Alarms/Indicators › Propeller Direction Indicator
Issued 14 October 2008
Resolved
Shaft tachs not working properly.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 24 November 2008
Resolution: Shaft tachs repaired and tested sat.
Documentation › Safety/Response Plans/Programs › Vessel Response Plan
Issued 14 October 2008
Resolved
Non tank vessel response plan has not been submitted and approved by MSC.
Due 20 November 2008
Resolved 11 September 2009
Resolution: Approved plan onboard.
Electrical › Electrical Distribution System (service) › Distribution Panel Bus
Issued 14 October 2008
Resolved
Reverse power relays were out of adjustment, delay was too retarded.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 21 November 2008
Resolution: Reverse power relays were adjusted and tested sat.
Lifesaving › Inflatable Liferafts › Capacity
Issued 8 November 2007
Resolved
Provide either 100% each side of the vessel or 150% total capacity of Liferafts prior to sailing.
Condition: Placed in Improper Service
Action required: 705 - Other - as specified
Due 8 November 2007
Resolved 13 November 2007
Resolution: Installed an additional 20 Person Liferaft on the Stbd side.
Lifesaving › Rescue Boat › Embarkation/Disembarkation Capabilities
Issued 9 January 2007
Resolved
Demonstrate proper operation of rescue boat winch.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 9 January 2007
Construction/Loadline
Issued 10 March 1998
Resolved
CROP AND RENEW FREEZER AFT BULKHEAD AND OVERHEAD GUSSETS. CROP AND RENEW VERTICAL AND LONGITUDINAL ANGLE IRON IN WAY OF FREEZER SPACE ON SIDE SHELL.CROP AND RENEW ALL TRIPPED ANGLE IRON AND OVERHEAD ANGLES IN THE EXHAUST TRUNK ROOM.
Condition: Unknown
Due 15 April 1998
Resolved 17 March 1998
Documentation
Issued 18 February 1994
Resolved
02. SUBMIT AUTOMATION TEST PROCEDURE TO OCMI FOR APPROVAL.
Condition: Unknown
Due 18 February 1994
Resolved 18 February 1994
Engineering
Issued 18 February 1994
Resolved
01. RENEW BRIDGE PORT MAIN ENGINE TACH.
Condition: Unknown
Due 18 February 1994
Resolved 18 February 1994
Unknown
Issued 30 March 1993
Resolved
INSTALL CONTAINMENT AROUND LUBE OIL FILL ON PORT SIDE MAIN DECK BEFORE USING FILL BUT NOT LATER THAN 30NOV93.
Condition: Unknown
Due 30 March 1993
Resolved 30 March 1993
Electrical
Issued 30 March 1993
Resolved
INSTALL EMERGENCY LIGHTING IN DIVER WORKSHOP AND TO ILLUMINATE STAIRWAY LEADING FROM MESSDECK DOWN TO SECOND DECK.
Condition: Unknown
Due 31 March 1993
Resolved 31 March 1993
Accommodation/Occupational Safety
Issued 3 February 1992
Resolved
RENEW AS NECESSARY AND RESTORE TO ORIGINAL THE FOLLOWING PRESSURE VESSELS FOR HUMAN OCCUPANCY: MAIN DECK DECOMPRESSION CHAMBER; ENTRANCE LOCK; SUBMERSIBLE DIVING CHAMBER.
Condition: Unknown
Due 11 February 1992
Resolved 11 February 1992
Construction/Loadline
Issued 3 February 1992
Resolved
MAKE PERMANENT REPAIRS IN WAY OF DAMAGE ON PORT SIDE OF VESSEL AT LOCATION NEAR LUBE OIL TANK APPROXIMATELY AT THE PLIMSOL MARK.
Condition: Unknown
Due 11 February 1992
Resolved 11 February 1992
Unknown
Issued 19 December 1990
Resolved
REPLACE THE TWO MISSING BII FIRE EXTINGUISHERS IN COMPRESSOR ROOM.
Condition: Unknown
Due 19 December 1990
Resolved 19 December 1990
Unknown
Issued 19 December 1990
Resolved
PROPERLY STOW NITROGEN BOTTLE IN COMPRESSOR ROOM.
Condition: Unknown
Due 19 December 1990
Resolved 19 December 1990
Unknown
Issued 19 December 1990
Resolved
SECURE PROPERLY BV FIRE EXTINGUISHERS IN COMPRESSOR ROOM AND ADJACENT DECK.
Condition: Unknown
Due 19 December 1990
Resolved 19 December 1990
Fire Fighting
Issued 19 December 1990
Resolved
PROPERLY SECURE B/V IN ENGINE ROOM AND ADJACENT DECKING.
Condition: Unknown
Due 19 December 1990
Resolved 19 December 1990
Fire Fighting
Issued 19 December 1990
Resolved
REPLACE TWO MISSING BII FIRE EXTINGUISHERS.
Condition: Unknown
Due 19 December 1990
Resolved 19 December 1990
Fire Fighting
Issued 19 December 1990
Resolved
REPLACE TWO MISSING FIRE EXTINGUISHERS IN ENGINE ROOM.
Condition: Unknown
Due 19 December 1990
Resolved 19 December 1990
Construction/Loadline
Issued 19 December 1990
Resolved
REPLACE GASKET AND CHALK TEST WTD AFT BULKHEAD OF COMPRESSOR ROOM.
Condition: Unknown
Due 19 December 1990
Resolved 19 December 1990
Electrical
Issued 8 February 1990
Resolved
SUBMIT DATA TO SHOW THE PROVISIONS OF 46 CFR 197.326 AND 46 CFR 197.328 (C)(18) HAVE BEEN MET OR INSTALL EQUIPMENT MEETING NFPA REQUIREMENTS AND NATIONAL ELECTRIC CODE REQUIREMENTS FOR HYPERBARIC FACILITES.
Condition: Unknown
Due 8 February 1990
Resolved 8 February 1990
Navigation
Issued 8 February 1990
Resolved
PROVIDE HYDROSTATIC TEST AND DOCUMENTATION TO [name withheld] FOR HELIUM/ OXYGEN MIXING VOLUME TANK IN CONTROL ROOM.
Condition: Unknown
Due 8 February 1990
Resolved 8 February 1990
Documentation
Issued 8 February 1990
Resolved
PROVIDE ADDITIONAL CERTIFICATED LIFEBOATMAN FOR VESSEL. ADDITIONAL INSTRUC-TION PROVIDED FOR ABLE SEAMAN LIMITED TIM BILLIOT PRIOR TO ISSUANCE OF "INCLUDING CERTIFICATED LIFEBOATMAN".
Condition: Unknown
Due 8 February 1990
Resolved 8 February 1990
Electrical
Issued 8 February 1990
Resolved
PROVIDE COVERS FOR JUNCTION BOXES LOCATED ON PERMANENTLY INSTALLED CHAMBERS
Condition: Unknown
Due 8 February 1990
Resolved 8 February 1990
Unknown
Issued 8 February 1990
Resolved
SUBMIT FOR APPROVAL PLANS SHOWING INSTALLATION OF FULTON 15HP HOT WATER HEATING BOILER (OIL FIRED) TO OCMI.
Condition: Unknown
Due 8 February 1990
Resolved 8 February 1990
Lifesaving
Issued 2 May 1989
Resolved
PROVIDE ON BOARD AN APPROVED RESCUE BOAT. 46 CFR 94.10-5(E)(1)(2).
Condition: Unknown
Due 2 May 1989
Resolved 2 May 1989
Deck/Cargo
Issued 12 February 1988
Resolved
PENDING REVIEW AND APPROVAL OF STABILITY AND STRUCTURAL PLANS, AFT GEAR HANDLING CRANE SHALL NOT BE USED.
Condition: Unknown
Due 12 February 1988
Resolved 12 February 1988
Unknown
Issued 12 February 1988
Resolved
AS PER 46 CFR 197.328(D)(13), INSTALL A PRESSURE RELIEVING SAFETY DEVICE ON THE VESSEL'S SATURATION SYSTEM. THE SYSTEM SHALL NOT BE PLACED INTO SERVICE UNTIL INSPECTED AND APPROVED BY THE CONGNIZANT OCMI.
Condition: Unknown
Due 12 February 1988
Resolved 12 February 1988
Unknown
Issued 24 June 1984
Resolved
PRIOR TO PLACING VESSEL'S DIVING SUPPORT SYSTEM INTO SERVICE, MAKE AVAIL- ABLE ALL REQUIRED EQUIPMENT AS LISTED IN 46 CFR 197 FOR A CG INSPECTOR.
Condition: Unknown
Due 24 June 1984
Resolved 24 June 1984
Documentation
Issued 24 June 1984
Resolved
PROVIDE APPROVED PLANS FOR THE ENGINE ALARM SYSTEM (UNMANNED ENGINE ROOM MONITOR) TO [name withheld], TEXAS AS REQUIRED IN NVIC 1-78.
Condition: Unknown
Due 24 June 1984
Resolved 24 June 1984
Electrical
Issued 24 June 1984
Resolved
REPAIR THE ENGINE ROOM SOUND POWER PHONE, BELL AND LIGHT AND PROVE SATISFACTORY OPERATION.
Condition: Unknown
Due 24 June 1984
Resolved 24 June 1984
Unknown
Issued 24 June 1984
Resolved
THE FOLLOWING DEFICIENCIES ARE FOR THE CAL DIVER I (EX SEA LEVEL 11), DN555055.
Condition: Unknown
Due 24 June 1984
Resolved 24 June 1984
Lifesaving
Issued 24 June 1984
Resolved
PROVIDE HAND BRAKE FOR THE RESCUE BOAT DAVIT WINCH.
Condition: Unknown
Due 24 June 1984
Resolved 24 June 1984