MAURY USCG vessel records Sign in
← All vessels

EURO SKYE

EURO SKYE is a 1997 tank ship. The Coast Guard has recorded 14 inspections since 1998, most recently in August 2006, along with 3 deficiencies — 2 with no resolution recorded — and 3 operational controls.

Records from 1998 to 2006. Most recent: inspection, 28 August 2006.

Built
1997
Last inspected
28 August 2006
Documentation
Not in the documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

9147734 View on MarineTraffic leaves Maury; a third-party site, nothing from it is stored here
478633
Flag
ITALY
—
Maury page id
psix-478633

Inspections, by type

…with no type recorded6
Years with a record 4 calendar years (1998–2006)
The 14 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

This record may be incomplete: the most recent inspection recorded for this vessel was 20 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Tank Ship class in Maury's sources begin in 1980.

Documentation record

Tonnage as PSIX records it3000 - Regulatory (Subpart C or D), Net Ton
6572 - Regulatory (Subpart C or D), Gross Ton
9488 - Dead Weight, Ton
This hull's Official Number is not in the NVDC file dated 10 September 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.

Radio station licence

No FCC ship-station licence is recorded against this Official Number in the file of 6 September 2026. That is a fact about the licence file, not about the radio.

Inspection history · 14

28 August 2006 Administrative Inspection
Administrative · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 2761911
28 August 2006 Administrative Inspection
Administrative · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 2762098
27 August 2006 Type not recorded
No type recorded · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 2760549
25 August 2006 Deficiency Check
Physical examination · Marine Safety Unit Brownsville · USCG Heartland District (CGD-H) · Activity 2759251
25 August 2006 Type not recorded
No type recorded · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 2759837
19 August 2006 Type not recorded
No type recorded · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 2753232
18 August 2006 Ballast Water Examination · COC-TVE Annual · ISPS II Exam
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 2751910
15 August 2006 Deficiency Check
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 2748887
27 October 2000 Type not recorded
No type recorded · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 283472
27 October 2000 Letter of Compliance (Initial/Renewal)
Administrative · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 823317
19 August 1999 Type not recorded
No type recorded · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 432358
19 August 1999 Letter of Compliance (Initial/Renewal)
Administrative · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1116393
6 July 1998 Type not recorded
No type recorded · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 417655
6 July 1998 Letter of Compliance (Initial/Renewal)
Administrative · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 794229

Deficiency record · 3

Fire Fighting › Fixed Pressure Water-Spraying Fire Extinguishing System › Nozzles
Issued 18 August 2006 No resolution recorded
Several sprinkler heads for the cargo tank area are not operational IWO STBD AFT and find section. Fixed water Spray system must be fully operational prior to carring chemical cargoes.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Navigation › Collision/Grounding Avoidance › Radar
Issued 18 August 2006 Resolved
Radar onboard not operational. attest to proper operation and provide tech report to Coast Guard.
Condition: Damaged By Earlier Event
Action required: 17 - Rectify deficiencies prior to departure
Due 18 August 2006
Resolved 23 August 2006
Resolution: Vessel radar is operational, vessel provided tech report.
Deck/Cargo › Inert Gas System › Deck Distribution System
Issued 18 August 2006 No resolution recorded
Provide IGS recording ink prior to carrying chemical cargoes.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified