Records from 1998 to 2012. Most recent: inspection, 8 May 2012.
A report is not offered for this hull: Its record holds only 2 of the seven kinds of material a report is built from: inspections, deficiencies, operational controls, tow-unit appearances, casualty records, dimensions and documentation. That is a statement about the record, not about the vessel. Reports.
Inspection history · 19
8 May 2012
Administrative Inspection
Administrative · Sector Boston · USCG Northeast District (CGD-NE) · Activity 4305731
15 November 2010
Administrative Inspection
Administrative · Sector Boston · USCG Northeast District (CGD-NE) · Activity 3891802
11 July 2008
Administrative Inspection
Administrative · Sector Boston · USCG Northeast District (CGD-NE) · Activity 3264230
17 March 2008
Annual Inspection
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 3166179
12 December 2007
Internal Structural Exam · Examination of Repairs · In-Service Inspection · Hull Examination
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 3114301
20 March 2006
COI Inspection
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 2605565
16 November 2005
Hull Examination
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 2535605
22 March 2005
Re-Inspection
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 2316295
9 November 2004
Hull Examination
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 2241318
23 March 2004
Hull Examination · Re-Inspection
Physical examination · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 2147453
12 March 2003
Re-Inspection · Deficiency Check
Physical examination · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 1755829
21 March 2002
Re-Inspection · Hull Examination
Physical examination · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 1495636
13 March 2001
COI Inspection
Physical examination · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 1465623
7 May 2000
Re-Inspection · Hull Examination
Physical examination · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 1401239
14 August 1999
Type not recorded
No type recorded · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 134034
14 August 1999
Damage Survey
Physical examination · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 1393210
5 August 1999
Type not recorded
No type recorded · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 775343
23 March 1999
Re-Inspection
Physical examination · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 1126587
8 June 1998
Hull Examination · Initial Certification
Physical examination · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 1131477
Communications › Visual Communication › Red Warning Signal
Issued 17 March 2008
Resolved
Fuel shut off valves not labled properly.
Action required: 705 - Other - as specified
Due 21 March 2008
Resolved 24 March 2008
Resolution: Fuel shut-off valves labled sat.
Pollution Prevention/Response › Prevention Equipment › Bilge Monitor
Issued 17 March 2008
Resolved
Excess oil in bilge. Remove and clean.
Action required: 705 - Other - as specified
Due 21 March 2008
Resolved 24 March 2008
Resolution: All oil removed sat.
Construction/Loadline › Hull › Bracket
Issued 12 December 2007
Resolved
Repair strut wastage iwo port & stbd prop tunnel
Action required: 705 - Other - as specified
Due 19 December 2007
Resolved 12 March 2008
Resolution: Corrected
Construction/Loadline › Hull › Stiffener
Issued 20 March 2006
Resolved
Renew wasted stiffener/frame port side side shell
Action required: 701 - Prior to carriage of passengers/cargo
Due 31 March 2006
Resolved 22 March 2006
Resolution: Repaired
Lifesaving › Lifebuoys › Stowage
Issued 20 March 2006
Resolved
Renew water light clip
Action required: 705 - Other - as specified
Due 31 March 2006
Resolved 22 March 2006
Resolution: Corrected
Electrical › Lighting (emergency) › Battery Operated Lantern
Issued 20 March 2006
Resolved
Renew batteries in portable flash light.
Action required: 705 - Other - as specified
Due 31 March 2006
Resolved 22 March 2006
Resolution: Corrected
Engineering › Shafting/Propeller Arrangements › Coupling
Issued 22 March 2005
Resolved
Reinstall forward hinge assembly to ensure proper clearance from the rubber drive shaft boot.
Action required: 705 - Other - as specified
Due 24 March 2005
Resolved 24 March 2005
Operations/Management › Drills/Instruction
Issued 12 March 2003
Resolved
Renew the emergency broadcast placard. LEGACY COMPONENT DESC: Making Voice Radio Distress Call
Action required: 705 - Other - as specified
Due 31 March 2003
Resolved 19 March 2003
Engineering › Gasoline Engine (propulsion)
Issued 12 March 2003
Resolved
Prove proper operation of the fume detector. Not tested.
Action required: 705 - Other - as specified
Due 31 March 2003
Resolved 19 March 2003
Engineering › Bilge Water Management System
Issued 12 March 2003
Resolved
Prove proper operation of the bilge pumps and high bilge level alarm. LEGACY COMPONENT DESC: Pump
Action required: 705 - Other - as specified
Due 31 March 2003
Resolved 19 March 2003
Construction/Loadline › Markings › Draft Marks/Indicating System
Issued 12 March 2003
Resolved
Properly label the loading mark on the hull. LEGACY COMPONENT DESC: Load Line Mark
Action required: 705 - Other - as specified
Due 30 September 2003
Resolved 29 July 2004
Resolution: Per phone conversation, draft marks placed on vessel.
Fire Fighting › Portable Dry Chemical Fire Extinguisher
Issued 12 March 2003
Resolved
Provide servicing report for the fixed and portable extinguishers. LEGACY COMPONENT DESC: Service
Action required: 705 - Other - as specified
Due 31 March 2003
Resolved 19 March 2003
Engineering › Bilge Water Management System
Issued 21 March 2002
Resolved
Properly test the Bilge pumps, bilge alarms, and vapor detection system prior to carrying passengers
Action required: 701 - Prior to carriage of passengers/cargo
Due 4 April 2002
Resolved 28 March 2002
Construction/Loadline › Hull
Issued 21 March 2002
Resolved
Properly plug all of the holes on the deck of the bow.
Condition: Unknown
Due 4 April 2002
Resolved 28 March 2002
Engineering › Gasoline Engine (propulsion)
Issued 21 March 2002
Resolved
Tighten all of the bolts on the bracket attached to the aft portion of the forward boot.
Due 4 April 2002
Resolved 28 March 2002
Lifesaving
Issued 13 March 2001
Resolved
Unknown Component - Unknown Cause/Condition
Condition: Unknown
Due 31 March 2001
Resolved 26 March 2001