MAURY USCG vessel records
← All vessels

CRIMSON CLOVER

CRIMSON CLOVER is a 1998 freight barge. The Coast Guard has recorded 50 inspections since 1998, most recently in March 2026, along with 48 deficiencies, 5 operational controls and 5 casualty investigations between 2007 and 2023.

Records from 1998 to 2026. Most recent: inspection, 31 March 2026.

Built
1998
Last inspected
31 March 2026
Documentation
Valid · documentation file of 10 August 2026
Controls
None recorded without a removal date

Coast Guard record current through 23 August 2026, retrieved 5 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Barge class in Maury's sources begin in 1972.

Inspection record

Last inspected 31 March 2026
…with no type recorded15
Operational controls None recorded without a removal date
Years with a record 25 calendar years (1998–2026)
Every line above is a count of records the US Coast Guard wrote, or a date it recorded. A blank resolution means none was recorded in this data; it does not establish that a deficiency is outstanding. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Identity

478761
Flag
UNITED STATES
Maury page id
psix-478761

Documentation record

Registered dimensions (L × B × D)259.2 ft × 80.0 ft × 18.0 ft
Registered tonnagegross 3,289 / net 3,289
ITC dimensions (L × B × D)259.2 ft × 80.0 ft × 18.0 ft
ITC tonnagegross 7,040 / net 4,173
BuilderCONRAD INDUSTRIES, INC · MORGAN CITY, LA, UNITED STATES · built 1998
Hull materialSteel
PropulsionUNSPECIFIED
Hull shapeUNSPECIFIED
Hull configurationUNSPECIFIED
Hailing portWILMINGTON, DE
Trade endorsementsCoastwise, unrestricted, Registry
DocumentationValid · issued 24 July 2026 · expires 31 August 2027
Service, as the file records itFreight Barge
Hull formbarge (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it3289 - Regulatory (Subpart C or D), Gross Ton
7040 - Convention (Subpart B), Gross Ton
3289 - Regulatory (Subpart C or D), Net Ton
4173 - Convention (Subpart B), Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 August 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.
Vessel history report
Every record for this hull, in one document — $299

Every recorded inspection, 1972 to 2026 for this class, in one chronology · every deficiency, with system, dates and resolution · operational controls imposed and removed · every name this hull has been recorded under · the vessels it was inspected alongside, and when · how its record compares with hulls of similar age and size, as a fact about the population and never a judgement about this vessel.

Read one first, in full: a forty-year chronology · a hull that changed operators four times · the sparse case, shown as an example, not for sale.

This report is in development and is not for sale yet. There is no date, and nothing is charged. Leave an email and we will tell you when it exists, once.

Inspected as a tow unit · 8

Inspection history · 50

31 March 2026 Internal Structural Exam · Administrative Inspection · Annual Inspection
Physical examination · Marine Safety Unit Port Canaveral · USCG Southeast District (CGD-SE) · Activity 8338820
1 February 2026 Type not recorded
No type recorded · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 8305410
14 May 2025 Annual Inspection
Physical examination · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 8136132
7 May 2024 COI Inspection · Administrative Inspection · Deficiency Check
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 7908070
24 May 2023 COI Inspection · Administrative Inspection
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 7695686
6 April 2023 Drydock Exam · Examination of Repairs · Internal Structural Exam · Administrative Inspection
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 7664161
4 April 2023 Type not recorded
No type recorded · Sector Mobile · USCG Heartland District (CGD-H) · Activity 7662831
30 March 2023 Administrative Inspection
Administrative · Sector Mobile · USCG Heartland District (CGD-H) · Activity 7659579
8 August 2022 Administrative Inspection · Annual Survey
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 7527844
1 September 2021 Administrative Inspection · MARPOL Annex I Examination · MARPOL Annex VI Survey · Deficiency Check · Annual Inspection
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 7301766
7 June 2021 Internal Structural Exam · Deficiency Check · Administrative Inspection
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 7218286
1 May 2020 Annual Inspection · Deficiency Check · Administrative Inspection
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 6946805
31 May 2019 Administrative Inspection · Annual Inspection · MARPOL Annex I Examination · MARPOL Annex VI Survey
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 6699358
25 April 2018 Examination of Repairs · Administrative Inspection · Drydock Exam · Internal Structural Exam · COI Inspection
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 6399564
21 September 2017 Administrative Inspection · Annual Inspection · Deficiency Check · MARPOL Annex I Examination · MARPOL Annex VI Survey
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 6271486
22 August 2016 Damage Survey · Drydock Exam · Administrative Inspection · COI Inspection
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 5979648
20 August 2016 Type not recorded
No type recorded · Sector Mobile · USCG Heartland District (CGD-H) · Activity 5989381
13 June 2016 Drydock Exam · Internal Structural Exam
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 5909344
20 August 2015 Deficiency Check · Annual Inspection
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 5221718
20 August 2015 Type not recorded
No type recorded · Sector Mobile · USCG Heartland District (CGD-H) · Activity 5221861
5 October 2014 Damage Survey · Administrative Inspection
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 4999210
1 October 2014 Type not recorded
No type recorded · Sector Mobile · USCG Heartland District (CGD-H) · Activity 5003070
15 September 2014 Deficiency Check · Administrative Inspection
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 4980626
20 August 2014 Periodic Inspection
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 4954920
22 October 2013 Annual Inspection
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 4739048
28 August 2013 Internal Structural Exam
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 4700089
24 October 2012 Deficiency Check
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 4471280
21 October 2012 MTSA/ISPS Verification
Physical examination · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 4469771
22 August 2012 MTSA Verification · Administrative Inspection · Annual Inspection
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 4419123
14 July 2011 Deficiency Check · Internal Structural Exam · Initial Certification · Drydock Exam
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 4101791
22 February 2010 Type not recorded
No type recorded · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 3683932
10 February 2010 MARPOL Annex I Examination · Initial Certification · Deficiency Check
Physical examination · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 3677643
23 June 2009 Type not recorded
No type recorded · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 3511714
22 June 2009 MTSA Verification
Physical examination · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 3511159
13 February 2008 Type not recorded
No type recorded · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 3149563
4 September 2007 Deficiency Check
Physical examination · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 3048798
25 August 2007 Type not recorded
No type recorded · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 3044103
16 August 2007 Type not recorded
No type recorded · Sector Mobile · USCG Heartland District (CGD-H) · Activity 3030807
4 August 2007 Type not recorded
No type recorded · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 3017532
4 August 2007 MTSA Verification
Physical examination · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 3020061
21 October 2006 MTSA Verification
Physical examination · Sector Charleston · USCG Southeast District (CGD-SE) · Activity 2805162
2 May 2005 Security Plan Amendment Review - VSP
Administrative · Marine Safety Center (MSC) · Activity 2347333
13 December 2004 Deficiency Check · MTSA Verification
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 2258486
10 August 2004 MTSA Verification
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 2160785
30 March 2004 Type not recorded
No type recorded · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 2033944
15 March 2004 Type not recorded
No type recorded · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 2024719
1 August 2002 Type not recorded
No type recorded · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 1656187
14 August 1998 Type not recorded
No type recorded · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 797482
26 May 1998 Initial Construction-Excluding Oversight
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1415074
26 February 1998 Initial Construction-Excluding Oversight
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1368639

Deficiency record · 48

14 - Pollution Prevention › 141 - MARPOL Annex I › Other (MARPOL Annex I)
Issued 14 May 2025 Resolved
Discharge removal equipment for vessels less than 400 feet in length (b) equipment and supplies must include: 1) sorbents 2) non-sparking and hand scoops, shovels, and buckets; 3) containers suitable for holding recovered waste; 4) emulsifiers for deck cleaning; 5) protective clothing; 6) a minimum of one non-sparking portable pump with hoses; and 7) scupper plugs. "Spill Kit" was found empty.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 11 June 2025
Resolution: Provided updated spill kit.
14 - Pollution Prevention › 146 - MARPOL Annex VI › Other (MARPOL Annex VI)
Issued 14 May 2025 Resolved
Exhaust gas must not leak from the piping or any connections. The piping must be properly supported by noncombustible hangers or blocks. Exhaust gas was found leaking from piping.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 15 June 2025
Resolved 11 June 2025
Resolution: Replaced gasket.
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 14 May 2025 Resolved
Each outlet or junction box must be securely attached to its mounting and be affixed so as to maintain its designated degree of protection. Junction box found not mounted properly.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 15 June 2025
Resolved 11 June 2025
Resolution: Mounted junction box.
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 14 May 2025 Resolved
Each cable entrance in a damp or wet location must be made watertight by a terminal or stuffing tube. Packing on junction box was deteriorated.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 15 June 2025
Resolved 11 June 2025
Resolution: Repacked openings.
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 14 May 2025 Resolved
All electrical appliances, including, but not limited to, cooking equipment, dishwashers, refrigerators, and refrigerated drinking water coolers, must meet ANSI/UL safety and construction standards or equivalent standards under § 110.20-1 of this chapter. Also, this equipment must be suitably installed for the location and service intended. Dead end wires found inside forward and outside bow starboard.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 15 June 2025
Resolved 11 June 2025
Resolution: Removed dead end wires.
09 - Working and Living Conditions › 092 - Working Conditions › Other (accident prevention)
Issued 14 May 2025 Resolved
Except as provided in § 108.540(h)(3)(ii), each exterior vertical ladder more than 6 meters (20 ft.) in length must be fitted with a cage or ladder safety device meeting ANSI Standard 14.3 (1974) for fixed ladders. Exterior ladders missing cage/safety device.
Condition: Invalid
Action required: 50 - Rectify deficiencies w/in 30 days
Due 15 June 2025
Resolved 11 June 2025
Resolution: Attached frame to ladder.
09 - Working and Living Conditions › 092 - Working Conditions › Other (accident prevention)
Issued 14 May 2025 Resolved
All tank vessels in ocean and coastwise service, except unmanned tank barges, constructed on or after June 15, 1987, must have suitable storm rails installed in all passageways and at the deckhouse sides on weather decks where persons on board might have normal access. Starboard side (3) rails were found deteriorated.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 15 June 2025
Resolved 11 June 2025
Resolution: Replaed hand rails.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 14 May 2025 Resolved
Batteries must be constructed to take into account the environmental conditions of a marine installation, including temperature, vibration, and shock. Wing nuts were found on batteries.
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 15 June 2025
Resolved 11 June 2025
Resolution: Replaced wiing nuts.
07 - Fire Safety › N/A - No Subsystem › Ventilation
Issued 30 May 2024 Resolved
Means shall be provided for stopping all fans in ventilation systems serving machinery and cargo spaces and for closing all doorways, ventilators and annular spaces around funnels and other openings to such spaces, from outside these spaces, in case of fire. Ventilation to machinery space could not be closed.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 10 June 2024
Resolution: Observed ventilation closures operating properly.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Operation of machinery
Issued 7 May 2024 Resolved
The installation of all systems of a marine engineering nature, together with the details of design, construction, and installation, shall be in accordance with the requirements of subchapter F (Marine Engineering) of this chapter. Exhaust leak was identified on emergency generator.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 10 June 2024
Resolution: Observed emergency generator operating with no apparent exhaust leak.
02 - Structural Conditions › N/A - No Subsystem › Closing devices/watertight doors
Issued 7 May 2024 Resolved
Each vessel must meet the applicable requirements in subchapter S of this chapter. Several hatches were found with inadequate gaskets and water in the voids. Replace all gaskets.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 13 June 2024
Resolved 6 June 2024
Resolution: Received objective evidence of all gaskets renewed.
07 - Fire Safety › N/A - No Subsystem › Operation of Fire protection systems
Issued 24 May 2023 Resolved
CO2 systems which are of more than 300 pounds of carbon dioxide, shall be fitted with an approved delayed discharge so arranged that the alarm will be sounded for at least 20 seconds before the carbon dioxide is released into the space. Vessel is fitted with two independent 200 pound systems that discharge into the same space, which would equal 400 pounds into the space. Install time delay alarm IAW above regulations.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 8 June 2023
Resolved 30 June 2023
Resolution: Deficiency cleared, time delay and odorizer were installed as requested; vessel requested 1 year extension to provide adequate amount of lbs of CO2 in the space provided. See special notes.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Auxiliary engine
Issued 24 May 2023 Resolved
Each generator prime mover must have an overspeed device that is independent of the normal operating governor and adjusted so that the speed cannot exceed the maximum rated speed by more than 15%. Vessel rep stated prime movers had exemption letter machinery and were not tested. Provide documentation of CG exemption from testing or install overspeed device IAW manufacturer specifications and regulations.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 8 June 2023
Resolved 30 June 2023
Resolution: Cleared, determined overspeed not required on engines.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Auxiliary engine
Issued 24 May 2023 Resolved
Each generator shall follow the minimum instrumentation alarms, and safety controls required by the table in 46 CFR 62.35-50. Fwd John Deere generator did not meet the high jacket water safety controls causing alarms. Repair jacket water sensor to meet the requirements.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 8 June 2023
Resolved 30 June 2023
Resolution: Cleared, tested SAT.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Cargo & other hatchways
Issued 3 September 2021 Resolved
The means for securing and maintaining weathertightness shall be to the satisfaction of the assigning authority. Inspectors identified a 3" hole on the STBD side of the cargo hold bulkhead. Vessel must make weathertight, the hole found.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 3 September 2021
Resolved 8 September 2021
Resolution: Vessel welded plate over hole found in bulkhead.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 3 September 2021 Resolved
An electric apparatus must be designed, constructed, and installed to prevent any person from accidentally contacting energized parts. Breaker panel in engine room vestibule had an opening on the panel. Vessel must install a cover over opening.
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 17 September 2021
Resolved 8 September 2021
Resolution: Vessel added plate to properly seal up opening in breaker panel.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 3 September 2021 Resolved
Each panelboard must have: A circuit directory cardholder; and The circuit designation of each circuit;(ii) A description of the load of each circuit. Panel board located in engine room vestibule did not have a readable directory. Must make and install a new directory.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 17 September 2021
Resolved 8 September 2021
Resolution: Vessel made and installed new panel directories.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Covers (hatchway-, portable-, tarpaulins, etc.)
Issued 11 May 2020 Resolved
Emergency escape hatch from machinery room to the main deck was found wasted and inoperable. Repair or replace.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 20 May 2020
Resolution: A new emergency escape hatch from machinery room to the main deck was satisfactorily installed and demonstrated fully operable as designed.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Covers (hatchway-, portable-, tarpaulins, etc.)
Issued 11 May 2020 Resolved
Gasket material for all void spaces on the outer deck were found to be wasted. Replace all gaskets for void spaces.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 20 May 2020
Resolution: Gasket material for all void spaces was satisfactorily replaced with all new gaskets.
09 - Working and Living Conditions › 092 - Working Conditions › Other (accident prevention)
Issued 11 May 2020 Resolved
01 handrail on outer deck found wasted. Repair or replace.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 20 May 2020
Resolution: New handrail was properly installed on outer deck
09 - Working and Living Conditions › 092 - Working Conditions › Other (accident prevention)
Issued 11 May 2020 Resolved
Provide handrails for areas above cleats on both the port and starboard side of the vessel.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 20 May 2020
Resolution: Chain-link was installed above cleats on both the port and starboard side of the vessel.
09 - Working and Living Conditions › 092 - Working Conditions › Other (accident prevention)
Issued 11 May 2020 Resolved
The stern of the vessel does not contain any guard rails to protect persons from falling overboard. Install appropriate guard rail as required by 46 CFR 92.25-5.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 20 May 2020
Resolution: Chain-link was installed on the stern of the vessel to protect persons from falling overboard.
Fire Fighting › Fixed CO2 Fire Extinguishing System › Piping
Issued 21 September 2017 Resolved
Fixed CO2 fire fighting systems flexible hoses are cracked on 2 of 4 hoses. Replace with approved hoses to the satisfaction of attending marine inspector.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 21 October 2017
Resolved 22 September 2017
Resolution: CO2 flexible hoses were replaced. Def Cleared.
Construction/Loadline › Hull › Hull Plating
Issued 22 August 2016 Resolved
The stbd bow rake was damaged in an event with a bridge. An area of about 20' x 20' was effected. Logitudinals and transverse framing and steel plate must be cropped and renewed.
Condition: Damaged By Earlier Event
Action required: 705 - Other - as specified
Due 22 September 2016
Resolved 1 September 2016
Resolution: Hull was repaired and tested to the satisfaction of the attending CGMI.
Engineering › Lubricating Oil Storage/Transfer System › Hose
Issued 20 August 2015 Resolved
While testing the barge stern loading ramps, a hydraulic line failed resulting in a discharge of hydraulic oil and inoperable loading ramp. Issued CG-835 requiring the vessel to prove proper operation of loading ramp prior to conducting cargo operations.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 4 September 2015
Resolution: Hydraulic hoses were replaced/properly tightened down. Satisfactorily tested both aft and forward loading ramps.
Fire Fighting › Portable CO2 Fire Extinguisher › Mounting Bracket
Issued 20 August 2015 Resolved
Fire extinguisher bracket wasted, properly secure fire extinguisher with an approved bracket at engine room watertight door.
Action required: 705 - Other - as specified
Due 27 August 2015
Resolved 28 August 2015
Resolution: Wasted fire extinguisher bracket was replace with approved bracket.
Electrical › Electrical Distribution System (service) › Cable
Issued 20 August 2015 Resolved
Properly secure all electrical wires/cables w/ metal fasteners every 24 inches throughout the barge.
Action required: 705 - Other - as specified
Due 20 September 2015
Resolved 28 August 2015
Resolution: All wires/cables were properly secured with metal fasteners.
Electrical › Electrical Distribution System (service) › Circuit Breaker
Issued 20 August 2015 Resolved
Properly label all electrical panels and motor controllers
Action required: 705 - Other - as specified
Due 20 September 2015
Resolved 28 August 2015
Resolution: All electrical panels and motor controllers were proplery labled.
Electrical › Electrical Distribution System (service) › Cable
Issued 20 August 2015 Resolved
Properly secure all battery cables.
Action required: 705 - Other - as specified
Due 27 August 2015
Resolved 28 August 2015
Resolution: All battery cables were properly secured.
Stability › Watertight Integrity › General
Issued 20 August 2015 Resolved
Prove proper operation of engine room watertight door.
Action required: 705 - Other - as specified
Due 27 August 2015
Resolved 28 August 2015
Resolution: Tested operation of door to include chalk test, which test satisfactory.
Electrical › Electric Supply System (service) › Battery Installation
Issued 20 August 2015 Resolved
Provide battery box cover for engine room batteries.
Action required: 705 - Other - as specified
Due 20 September 2015
Resolved 28 August 2015
Resolution: Battery box cover was provided.
Stability › Watertight Integrity › General
Issued 20 August 2015 Resolved
Watertight door leading to engineroom has wastage at bottom of door. Repair or replace watertight door.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 28 September 2015
Resolved 24 September 2015
Resolution: Verified proper installation of watertight door. Def cleared.
Fire Fighting › Fixed CO2 Fire Extinguishing System › Piping
Issued 20 August 2014 Resolved
Flexible unservicable hose on CO2 system are cracked. Replace flexible hose in accordance with 46 CFR 95.15-1. Vessel is restricted from carrying packaged hazardous cargo until deficiency is cleared by CG Marine Inspector.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 27 August 2014
Resolved 28 August 2014
Resolution: Replaced flexible hose & proved proper operation of CO2 system in presence of attending marine inspector.
Deck/Cargo › Holds/Tanks › Hatch Cover
Issued 20 August 2014 Resolved
#6P & #1S hatch cover gaskets are damaged. Replace gaskets in accordance with 46 CFR 97.15-20.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 20 September 2014
Resolved 21 August 2014
Resolution: Provided new gaskets for 6P & 1S hatch covers.
Electrical › Electrical Distribution System (service) › Cable
Issued 20 August 2014 Resolved
Cables in bow & stern section of the vsl are loose & hanging. Properly secure all electrical cables w/metal rings every 24 inches throughout vessel in accordance with 46 CFR 111.60-5(a)(1)
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 20 September 2014
Resolved 15 September 2014
Resolution: Verified that cable supports were installed IAW IEEE Std 45-2002 Section 25.
Electrical › Electric Supply System (service) › Battery Installation
Issued 20 August 2014 Resolved
Battery installation near John Deere Generator is loose due to improper installation using a wingnut. Replace wingnut in accordance with 46 CFR 111.15-5.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 20 September 2014
Resolved 15 September 2014
Resolution: Permanent-type connection was made between the terminal and the conductor.
Stability › Weathertight Integrity › General
Issued 20 August 2014 Resolved
Gland packing on cable near generator & for aft winch is wasted. Replace cable gland packing in accordance with 46 CFR 171.111(e)
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 20 September 2014
Resolved 15 September 2014
Resolution: The packing gland was replaced.
Construction/Loadline › Structures › Ventilators
Issued 20 August 2014 Resolved
2 cargo fan were inoperable. Repair or replace inoperable cargo ventilation fans in accordance with 46 CFR 92.15-10. Vessel is prohibited from carrying packaged hazardous cargo until fans are fully operable and deficiency has been cleared by attending CG Marine Inspector.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 20 September 2014
Resolved 15 September 2014
Resolution: Witnessed proper operation of all cargo ventilation fans.
Fire Fighting › Ventilation Systems › Ducts
Issued 10 February 2010 Resolved
Provide adequate means of securing machinery space ventilation luvers.
Condition: Design Flaw
Action required: 17 - Rectify deficiencies prior to departure
Resolved 11 February 2010
Resolution: Vessel represenative provided adequate means of securing machinery space ventilation luvers through the use of pins.
Stability › Watertight Integrity › General
Issued 10 February 2010 Resolved
Service all exterior water tight doors. "Dogs" are siezed and will not secure. Discrepant doors are located on the portside, one amidship and the other two forward of the forward ramp
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 11 February 2010
Resolution: Vessel represenative provided adequate lubrication to the dogs on all watertight doors.
Fire Fighting › Ventilation Systems › Stairway Enclosure Ventilation
Issued 10 February 2010 Resolved
Ensure proper operation and servicing of machinery space watertight door.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 11 February 2010
Resolution: Vessel represenative provided adequate clearance to machinery space watertight door to ensure proper operation.
Electrical › Lighting (service) › Conductor
Issued 10 February 2010 Resolved
Properly secure forward exterior wiring for external lights.
Condition: Improper Installation
Due 13 March 2010
Resolved 11 February 2010
Resolution: Vessel represenative adequately secured external wiring for lights.
Engineering › Fuel Oil Service System › Valve
Issued 10 February 2010 Resolved
Ensure proper labeling of remote emergency F/O daytank shutoff.
Condition: Improper Installation
Due 25 February 2010
Resolved 23 February 2010
Resolution: Represenative properly labeled remote fuel shutoff valve on main deck.
Fire Fighting › Means of Escape › Number
Issued 10 February 2010 Resolved
Provide secondary means of escape for/from machinery space. (Existing hatch had been remove and replaced with a welded plate.)
Condition: Design Flaw
Due 25 February 2010
Resolved 23 February 2010
Resolution: Represenative provided an adequate secondary escape hatch for engine space.
Engineering › Fuel Oil Service System › Filter
Issued 10 February 2010 Resolved
Install flame shields on dual racor filters and forward SSDG.
Condition: Improper Installation
Action required: 17 - Rectify deficiencies prior to departure
Resolved 11 February 2010
Resolution: Vessel represenative installed dual racor filters on forward SSDG.
Electrical › Electrical Distribution System (service) › Metallic Enclosure/Frame
Issued 10 February 2010 Resolved
Ensure proper securing of electrical distribution panels, IWO port side entry to machinery space.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 11 February 2010
Resolution: Vessel represenative provided adequate securing of electrical distribution panels.
Electrical › Electric Supply System (service) › Transformer
Issued 10 February 2010 Resolved
Remove cable to shore-tie transformer, which has been cut to bitter end.
Condition: Improper/Lack of Maintenance
Due 25 February 2010
Resolved 11 February 2010
Resolution: Vessel represenative properly removed cable to shore-tied transformer.
Engineering › Diesel Engine (auxiliary) › Piping (exhaust)
Issued 10 February 2010 Resolved
Ensure proper operation of engine exhaust lagging on botth SSG's, to a height above where persons can reach and contact piping.
Condition: Improper Installation
Due 25 February 2010
Resolved 11 February 2010
Resolution: Vessel represenative provided adequate exhaut lagging.

Casualty record · 5

16 August 2007Routine · role: Involved in a Marine Casualty · serious marine incident, as classified · activity 3030807
13 February 2008Routine · role: Involved in a Marine Casualty · activity 3149563
1 October 2014Routine · role: Involved in a Marine Casualty · activity 5003070
20 August 2016Routine · role: Involved in a Marine Casualty · activity 5989381
4 April 2023Routine · role: Involved in a Marine Casualty · activity 7662831
Each line is an incident investigation the Coast Guard recorded with this hull among the vessels involved, with the date and the classification the Coast Guard gave it. Involvement is not fault. The investigation narrative is not published. Source: IIR, through 2026.

Recorded names · 1

HELEN II (2007). Names as the Coast Guard recorded them in incident records, with the years they appear; some are renames and some are spelling variants.

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.