Records from 1998 to 2015. Most recent: inspection, 12 November 2015.
Inspection history · 23
12 November 2015
Administrative Inspection
Administrative · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 5762560
27 October 2010
COI Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 3878310
3 December 2009
Re-Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 3644241
30 October 2008
Hull Examination · MTSA Verification · Administrative Inspection · Periodic Inspection
Physical examination · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 3357993
13 December 2007
Re-Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 3114948
16 October 2006
Re-Inspection · Ballast Water Examination · Hull Examination · MTSA Verification
Physical examination · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 2801852
21 September 2005
COI Inspection · MTSA Verification
Physical examination · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 2496976
30 November 2004
MTSA Verification · Re-Inspection · Administrative Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 2250392
23 December 2003
Security Plan Review - VSP
Administrative · Marine Safety Center (MSC) · Activity 1972202
30 October 2003
Hull Examination · Re-Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1938852
24 January 2003
Type not recorded
No type recorded · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1741269
12 September 2002
Re-Inspection
Physical examination · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 1674646
31 July 2002
Type not recorded
No type recorded · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1656730
21 September 2001
Hull Examination · Re-Inspection
Physical examination · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1441897
10 January 2001
Administrative
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1057731
3 October 2000
COI Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1421934
17 March 2000
Type not recorded
No type recorded · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 816378
15 March 2000
Deficiency Check
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1047675
11 February 2000
Administrative
Administrative · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1046933
11 February 2000
Deficiency Check · Damage Survey
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1046937
22 December 1999
Deficiency Check
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 813439
9 December 1999
Re-Inspection
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1465515
6 October 1998
Initial Construction-Excluding Oversight · Initial Certification · Inclining Experiment · Hull Examination
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1404659
Electrical › Electric Generation Source (emergency) › Generator
Issued 3 December 2009
Resolved
Vessel required to provide proof of tonnange less than 500 GT, re-admeasure to be under 500 GT or provide final emergency power IAW 112.05-5
Due 16 October 2011
Resolved 27 October 2010
Electrical › Lighting (emergency) › Lighting Fixture
Issued 3 December 2009
Resolved
Additional e-light needed in eng. room for generator flat egress.
Action required: 705 - Other - as specified
Resolved 4 December 2009
Resolution: E-light added.
Electrical › Electric Generation Source (emergency) › Power Requirement
Issued 3 December 2009
Resolved
E-power needed for PA system.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 4 December 2009
Resolution: Electrician hooked up and tested for inspector.
Fire Fighting
Issued 22 December 1999
Resolved
PROVIDE PROPOSAL FOR MODIFICATIONS TO FIXED CO2 SYSTEM WHICH ENSURES BOTH SPACES ARE PROTECTED AT ALL TIMES.
Condition: Unknown
Due 22 December 1999
Resolved 22 December 1999
Fire Fighting
Issued 22 December 1999
Resolved
UPON APPROVAL MAKE REQUIRED MODIFICATIONS AND PROVE SYSTEM IN THE PRESENCE OF A COAST GUARD MARINE INSPECTOR.
Condition: Unknown
Due 22 December 1999
Resolved 22 December 1999
Fire Fighting
Issued 22 December 1999
Resolved
IN LIEU OF ABOVE REQUIREMENTS VESSEL MAY INSTALL ADEQUATE BIII EXTINGUISHERS AS PER 46 CFR 132.220 TO THE SATISFACTION OF THE COGNIZANT OCMI.
Condition: Unknown
Due 22 December 1999
Resolved 22 December 1999
Lifesaving
Issued 9 December 1999
Resolved
Provide stencilling and remove stencilling from containers as required by 46CFR131.865.
Condition: Unknown
Due 9 December 1999
Resolved 9 December 1999
Electrical
Issued 9 December 1999
Resolved
Label all circuit directories in all electrical panelboards with breaker amperages.
Condition: Unknown
Due 9 December 1999
Resolved 9 December 1999
Construction/Loadline
Issued 9 December 1999
Resolved
Label watertight doors IAW 46CFR131.893.
Condition: Unknown
Due 9 December 1999
Resolved 9 December 1999
Documentation
Issued 9 December 1999
Resolved
Post COI and Stability Letter on bridge as required by 46 CFR 126.240.
Condition: Unknown
Due 9 December 1999
Resolved 9 December 1999
Lifesaving
Issued 9 December 1999
Resolved
Provide stencilling as required by 46CFR131.855.
Condition: Unknown
Due 9 December 1999
Resolved 9 December 1999
Lifesaving
Issued 9 December 1999
Resolved
Replace waterlight on sbd side forecastle deck.
Condition: Unknown
Due 9 December 1999
Resolved 9 December 1999
Construction/Loadline
Issued 9 December 1999
Resolved
Install bolts on man-hole covers for LM tanks.
Condition: Unknown
Due 9 December 1999
Resolved 9 December 1999
Fire Fighting
Issued 9 December 1999
Resolved
Provide proof of USCG approval for installed CO2 system as arranged on board. Approval is required for design and as installed.
Condition: Unknown
Due 9 December 1999
Resolved 9 December 1999
Lifesaving
Issued 9 December 1999
Resolved
Provide drills and log entries as required by 46CFR131.620.
Condition: Unknown
Due 9 December 1999
Resolved 9 December 1999
Fire Fighting
Issued 9 December 1999
Resolved
Update fire and safety plan to include embarkation stations.
Condition: Unknown
Due 9 December 1999
Resolved 9 December 1999
Navigation
Issued 9 December 1999
Resolved
Prove proper operation of Rudder-Angle-Indicators in Engine Room.
Condition: Unknown
Due 9 December 1999
Resolved 9 December 1999
Documentation
Issued 9 December 1999
Resolved
Provided Goast Guard-approved Machinery Automation Procedures.
Condition: Unknown
Due 9 December 1999
Resolved 9 December 1999
Lifesaving
Issued 9 December 1999
Resolved
Post Emergency Broadcast and Emergency Instructions placards.
Condition: Unknown
Due 9 December 1999
Resolved 9 December 1999
Lifesaving
Issued 9 December 1999
Resolved
Provided stencilling as required by 46CFR131.875.
Condition: Unknown
Due 9 December 1999
Resolved 9 December 1999
Lifesaving
Issued 9 December 1999
Resolved
Provide stencilling as required by 46CFR131.890.
Condition: Unknown
Due 9 December 1999
Resolved 9 December 1999
Documentation
Issued 9 December 1999
Resolved
Provide proof of USCG approval for SARTS.
Condition: Unknown
Due 9 December 1999
Resolved 9 December 1999
Documentation
Issued 9 December 1999
Resolved
Post all required MARPOL placards.
Condition: Unknown
Due 9 December 1999
Resolved 9 December 1999
Unknown
Issued 9 December 1999
Resolved
Prove relief valves (pop-offs) on air receivers.
Condition: Unknown
Due 9 December 1999
Resolved 9 December 1999
Lifesaving
Issued 9 December 1999
Resolved
Provided proof of EPIRB hudrostatic release installation date or replace.
Condition: Unknown
Due 9 December 1999
Resolved 9 December 1999
Lifesaving
Issued 9 December 1999
Resolved
Provide proof of EPIRB registration with NOAA and affix decal to EPIRB.
Condition: Unknown
Due 9 December 1999
Resolved 9 December 1999
Documentation
Issued 9 December 1999
Resolved
Provide bridge-to-bridge ratiotelephony certificate. Vessel limeted to 20 miles from land until cleared.
Condition: Unknown
Due 9 December 1999
Resolved 9 December 1999
Documentation
Issued 9 December 1999
Resolved
Provide cargo ship safety certificate. Vessel is restricted to no more than 20 miles from land until this is cleared.
Condition: Unknown
Due 9 December 1999
Resolved 9 December 1999
Lifesaving
Issued 9 December 1999
Resolved
Provide embarkation stations, embarkation illumination and embarkation aidsas required by 46CFR133,110 and 46CFR sub-chapter J.
Condition: Unknown
Due 9 December 1999
Resolved 9 December 1999
Navigation
Issued 9 December 1999
Resolved
Vessel must have 2 GMDSS radio operators on board at all times.
Condition: Unknown
Due 9 December 1999
Resolved 9 December 1999
Lifesaving
Issued 9 December 1999
Resolved
Provide 12 required red parachute flares.
Condition: Unknown
Due 9 December 1999
Resolved 9 December 1999
Navigation
Issued 9 December 1999
Resolved
Provided proof of GMDSS shore-based maintenance agreement or GMDSS technician on board.
Condition: Unknown
Due 9 December 1999
Resolved 9 December 1999
Fire Fighting
Issued 9 December 1999
Resolved
Prove fixed CO2 system.
Condition: Unknown
Due 9 December 1999
Resolved 9 December 1999