MAURY USCG vessel records Sign in
← All vessels

GARVEY

GARVEY is a 1998 passenger vessel (inspected). The Coast Guard has recorded 37 inspections since 1998, most recently in July 2026, along with 30 deficiencies.

Records from 1998 to 2026. Most recent: inspection, 9 July 2026.

Built
1998
Last inspected
9 July 2026
Documentation
Not in the documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

478972
Flag
UNITED STATES
—
Maury page id
psix-478972

Inspections, by type

…with no type recorded1
Years with a record 26 calendar years (1998–2026)
The 37 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Passenger Ship class in Maury's sources begin in 1977.

Documentation record

Tonnage as PSIX records it4 - Simplified, Gross Ton
4 - Simplified, Net Ton
This hull's Official Number is not in the NVDC file dated 10 September 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.

Radio station licence

No FCC ship-station licence is recorded against this Official Number in the file of 6 September 2026. That is a fact about the licence file, not about the radio.

A report is not offered for this hull: Its record holds only 2 of the seven kinds of material a report is built from: inspections, deficiencies, operational controls, tow-unit appearances, casualty records, dimensions and documentation. That is a statement about the record, not about the vessel. Reports.

Inspection history · 37

9 July 2026 Annual Inspection
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 8407718
15 July 2025 Annual Inspection · Deficiency Check
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 8168662
12 May 2025 Hull Examination · Internal Structural Exam
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 8133360
25 June 2024 Annual Inspection
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 7914054
22 June 2023 Annual Inspection
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 7714735
14 February 2023 Administrative Inspection · Hull Examination · Internal Structural Exam
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 7634031
26 May 2022 Deficiency Check · COI Inspection
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 7425910
3 June 2021 Annual Inspection · Deficiency Check
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 7214388
26 May 2021 Hull Examination
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 7207973
16 June 2020 Deficiency Check · Annual Inspection
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 6979207
24 May 2019 Annual Inspection · Deficiency Check
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 6691305
25 April 2019 Hull Examination
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 6678631
11 June 2018 Deficiency Check · Annual Inspection
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 6440682
24 May 2017 COI Inspection
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 6153501
20 April 2017 Hull Examination
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 6132298
1 June 2016 Annual Inspection
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 5898682
30 May 2014 Annual Inspection
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 4876778
23 May 2012 COI Inspection
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 4317735
9 December 2011 Administrative Inspection
Administrative · Sector Boston · USCG Northeast District (CGD-NE) · Activity 4204823
6 July 2011 Annual Inspection
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 4077865
16 July 2009 Annual Inspection
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 3540154
14 May 2009 Hull Examination · Administrative Inspection
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 3477585
5 June 2008 Annual Inspection
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 3228289
14 May 2007 Hull Examination · COI Inspection
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 2929751
26 June 2006 Re-Inspection
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 2692197
17 August 2005 Re-Inspection
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 2465866
15 April 2005 Hull Examination
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 2461560
7 July 2004 Re-Inspection
Physical examination · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 2123805
10 May 2004 Hull Examination
Physical examination · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 2063636
19 June 2003 Re-Inspection
Physical examination · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 1820812
6 May 2002 COI Inspection · Hull Examination
Physical examination · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 1613334
23 July 2001 Re-Inspection
Physical examination · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 1465675
20 July 2000 Hull Examination · Re-Inspection
Physical examination · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 1381967
23 July 1999 COI Inspection
Physical examination · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 1103128
12 July 1999 Administrative
Administrative · MSO PROVIDENCE · USCG Northeast District (CGD-NE) · Activity 1093837
17 July 1998 Type not recorded
No type recorded · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 1129816
13 July 1998 Hull Examination · Initial Certification
Physical examination · MSO PROVIDENCE · USCG Northeast District (CGD-NE) · Activity 1399002

Deficiency record · 30

07 - Fire Safety › N/A - No Subsystem › Fixed fire extinguishing installation
Issued 15 July 2025 Resolved
A vessel on which a pre-engineered fixed gas fire extinguishing system is installed must have the following equipment at the operating station:(1) A light to indicate discharge;(2) An audible alarm that sounds upon discharge; and(3) A means to reset devices used to automatically shut down ventilation systems and engines as required by paragraph (a)(3) of this section. Installed alarm for fixed fire fighting system was inoperable and did not provide visual or audible alarms.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 28 July 2025
Resolved 1 August 2025
Resolution: Replaced alarm system and successfully tested visual and audible alarm.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 15 July 2025 Resolved
Each life jacket, immersion suit, and ring life buoy must be marked in clearly legible block capital letters with the vessel's name. Marking of vessel's name on life jackets were rubbing off. Vessel's name was rewritten on affected life jackets.
Action required: 10 - Deficiency Rectified
Resolved 15 July 2025
Resolution: Cleared on the spot.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 15 July 2025 Resolved
Each lifejacket must be approved under approval series in subparts 160.002, 160.005, 160.055, 160.115, 160.176, or 160.255 in part 160 of this chapter, or other standard specified by the Commandant. 10 life jackets were deteriorating and no longer in serviceable condition. Life jackets were replaced.
Action required: 10 - Deficiency Rectified
Resolved 15 July 2025
Resolution: Cleared on the spot.
02 - Structural Conditions › N/A - No Subsystem › Steering gear
Issued 15 July 2025 Resolved
A vessel must be provided with an auxiliary means of steering that is: Capable of moving the rudder from 15 degrees on one side to 15 degrees on the other side in not more than 60 seconds with the vessel at one-half its maximum service speed ahead, or 7 knots, whichever is greater. Vessel did not have tool kit on board to operate the auxiliary means of steering. Tool kit was placed on board.
Action required: 10 - Deficiency Rectified
Resolved 15 July 2025
Resolution: Cleared on the spot.
04 - Emergency Systems › N/A - No Subsystem › Man Overboard Drill (MOB)
Issued 15 July 2025 Resolved
Abandon ship and man overboard drills and training shall be logged or otherwise documented for review by the Coast Guard upon request. Abandon ship and man overboard drills/training were not being logged. Man overboard drill conducted during inspection was logged.
Action required: 10 - Deficiency Rectified
Resolved 15 July 2025
Resolution: Cleared on the spot.
07 - Fire Safety › N/A - No Subsystem › Fixed fire extinguishing installation
Issued 26 May 2022 Resolved
A vessel on which a pre-engineered fixed gas fire extinguishing system is installed must have the following equipment at the operating station: (1) A light to indicate discharge; (2) An audible alarm that sounds upon discharge; and (3) A means to reset devices used to automatically shut down ventilation systems and engines as required by paragraph (a)(3) of this section. Fixed fire-fighting system did not provide any alarms (visual & audible) and did not secure engine.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 1 June 2022
Resolution: Service tech returned and corrected issues with FireBoy alarm system. Tested:SAT.
10 - Safety of Navigation › N/A - No Subsystem › Lights, shapes, sound-signals
Issued 3 June 2021 Resolved
A vessel of less than 12 meters in length shall not be obliged to carry sound signaling appliances prescribed in 33 CFR 83.33(a), but if she does not, she shall be provided with some other means of making an efficient sound signal. Vessel does not have a sound signaling appliance onboard.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 17 June 2021
Resolved 23 June 2021
Resolution: Sound signaling appliance satisfactorily replaced in kind.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 16 June 2020 Resolved
A submersible electric bilge pump may be used as a power bilge pump as required by table 182.520(a) provided that a positive shutoff valve is installed at the hull penetration. 01 hull penetration is not fitterd with a valve.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 1 July 2020
Resolved 9 July 2020
Resolution: Positive shutoff valve installed.
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 24 May 2019 Resolved
Fire extinguishing equipment must be maintained in accordance with a recognized industry standard. Two of the fire extinguishers had not been serviced annually.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 7 June 2019
Resolved 7 June 2019
Resolution: Fire extinguishers were serviced and proper tags were placed on them.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 24 May 2019 Resolved
Marine employers shall establish programs for the chemical testing for dangerous drugs on a random basis of crewmembers on inspected vessels who occupy a position required by the vessel's COI. One alternate Captain is not enrolled in the consortium.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 7 June 2019
Resolved 7 June 2019
Resolution: Operator enrolled alternate Master in random drug testing program.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 24 May 2019 Resolved
A vessel of at least 26 feet in length must have a visual and audible alarm must be provided at the operating station to indicate a high water level.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 7 June 2019
Resolved 7 June 2019
Resolution: Operator installed a visual alarm for the high water alarm.
Accommodation/Occupational Safety › Medical/First Aid › Medicine Chest
Issued 11 June 2018 Resolved
Update first aid kit IAW 46CFR160.41. 46CFR184.710
Action required: 16 - Rectify deficiencies w/in 14 days
Due 25 June 2018
Resolved 26 June 2018
Resolution: Updated.
Navigation › Collision/Grounding Avoidance › Navigation Lights
Issued 11 June 2018 Resolved
Ensure nav lights are operational. 33CFR83 Vessel is restricted to operating in good visibility.
Action required: 705 - Other - as specified
Due 11 June 2018
Resolved 26 June 2018
Resolution: Tested lights. All sat.
Documentation › Certificates/Documents › FCC Safety Radiotelephony Certificate
Issued 11 June 2018 Resolved
Ensure Vessel has a valid FCC Safety Certificate onboard. 47CFR80
Action required: 16 - Rectify deficiencies w/in 14 days
Due 25 June 2018
Resolved 26 June 2018
Resolution: Certificate provided.
Operations/Management › Drills/Instruction › Fire
Issued 11 June 2018 Resolved
Ensure emergency procedures are posted. 46CFR185.510
Action required: 16 - Rectify deficiencies w/in 14 days
Due 25 June 2018
Resolved 26 June 2018
Resolution: Instructions found in 3 ring binder.
Operations/Management › Drug and Alcohol Testing › Employee Coverage
Issued 5 June 2008 Resolved
Prove enrollment of current employees.
Action required: 705 - Other - as specified
Due 10 June 2008
Resolved 17 June 2008
Resolution: Corrected
Engineering › Sea-water System (primary cooling) › Piping
Issued 5 June 2008 Resolved
Renew cracked/dry-rotted non-metalic sea water hose from strainer to pump.
Action required: 705 - Other - as specified
Due 10 June 2008
Resolved 25 June 2008
Resolution: Corrected
Accommodation/Occupational Safety › Medical/First Aid › Medicine Chest
Issued 5 June 2008 Resolved
Renew expired contents of first aid kit.
Action required: 705 - Other - as specified
Due 10 June 2008
Resolved 25 June 2008
Resolution: Corrected
Navigation › Piloting/Steering › Marine Charts
Issued 5 June 2008 Resolved
Provide paper chart of operating area.
Action required: 705 - Other - as specified
Due 10 June 2008
Resolved 25 June 2008
Resolution: Corrected
Operations/Management › Drills/Instruction › Man Overboard Recovery
Issued 14 May 2007 Resolved
Conduct mob drills.
Action required: 701 - Prior to carriage of passengers/cargo
Due 25 May 2007
Resolved 25 May 2007
Fire Fighting › Fixed CO2 Fire Extinguishing System › Servicing
Issued 17 August 2005 Resolved
Service the fixed fire extinguishing system for the engine compartment.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 17 August 2005
Resolved 17 August 2005
Resolution: Fixed system serviced.
Communications › Radio Communications › VHF Radiotelephone
Issued 17 August 2005 Resolved
Update radio station liecense.
Action required: 705 - Other - as specified
Due 17 August 2005
Resolved 17 August 2005
Resolution: Radio liecense updated.
Lifesaving › Lifebuoys › Buoyant Lifeline
Issued 17 August 2005 Resolved
Replace ring buoy life line.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 17 August 2005
Resolved 17 August 2005
Resolution: Life line replaced.
Lifesaving › Visual Distress Signals (General) › Not on Board
Issued 7 July 2004 Resolved
Provide 3 orange smoke and 3 red flare distress signals.
Action required: 705 - Other - as specified
Due 9 July 2004
Resolved 7 July 2004
Resolution: Received fax copy of invoice for flares/smokes.
Electrical
Issued 6 May 2002 Resolved
Properly repair bonding wire at through hull fitting.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Resolved 14 May 2002
Resolution: repaired bonding wire
Engineering › Bilge Water Management System
Issued 6 May 2002 Resolved
Remount bilge pump strainer to bilge. LEGACY COMPONENT DESC: Strainer
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Resolved 14 May 2002
Resolution: remounted bilge pump strainer
Lifesaving
Issued 17 July 1998 Resolved
MAKE ENTIRE CREW AVAILABLE FOR MAN OVERBOARD DRILLS AND DAMAGE CONTROL TRAINING.
Condition: Unknown
Due 10 August 1998
Resolved 10 August 1998
Documentation
Issued 13 July 1998 Resolved
[withheld — contains personal information; the deficiency system, dates, and resolution status are shown above]
Condition: Unknown
Due 13 July 1998
Resolved 13 July 1998
Lifesaving
Issued 13 July 1998 Resolved
[withheld — contains personal information; the deficiency system, dates, and resolution status are shown above]
Condition: Unknown
Due 13 July 1998
Resolved 13 July 1998
Documentation
Issued 13 July 1998 Resolved
MAKE THE VESSEL AVAILABLE TO MSO BOSTON FOR A NEW TO ZONE INSPECTION PRIOR TO PLACING THE VESSEL IN SERVICE.
Condition: Unknown
Due 13 July 1998
Resolved 13 July 1998

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.