Records from 1998 to 2001. Most recent: inspection, 22 January 2001.
A report is not offered for this hull: Its record holds only 2 of the seven kinds of material a report is built from: inspections, deficiencies, operational controls, tow-unit appearances, casualty records, dimensions and documentation. That is a statement about the record, not about the vessel. Reports.
Engineering
Issued 23 September 1999
Resolved
Provide rigid-noncombustible exhaust and supply ducting for the fuel tank space.
Condition: Unknown
Due 23 September 1999
Resolved 23 September 1999
Engineering
Issued 23 September 1999
Resolved
Install a remote fuel shutoff valve at the fuel tank connection and mark valve with direction of operation. Valve shall be operable from outside the tank space.
Condition: Unknown
Due 23 September 1999
Resolved 23 September 1999
Engineering
Issued 23 September 1999
Resolved
Install metallic flame impingment bowls on the fuel filters.
Condition: Unknown
Due 23 September 1999
Resolved 23 September 1999
Fire Fighting
Issued 23 September 1999
Resolved
Prove proper operation of the heat detection system.
Condition: Unknown
Due 23 September 1999
Resolved 23 September 1999
Engineering
Issued 23 September 1999
Resolved
Provide an additional mechanical exhaust blower for the fuel tank space. Blower shall be intrinsically safe.
Condition: Unknown
Due 23 September 1999
Resolved 23 September 1999
Fire Fighting
Issued 23 September 1999
Resolved
Provide vent closures for the fuel tank space.
Condition: Unknown
Due 23 September 1999
Resolved 23 September 1999
Lifesaving
Issued 23 September 1999
Resolved
Properly install retro-reflective tape on both sides of the ring buoy.
Condition: Unknown
Due 23 September 1999
Resolved 23 September 1999
Engineering
Issued 23 September 1999
Resolved
Prove proper operation of the flammable vapor detector system in the fuel tank space.
Condition: Unknown
Due 23 September 1999
Resolved 23 September 1999
Construction/Loadline
Issued 23 September 1999
Resolved
Provide a portable bilge pump with sufficient suction and discharge hoses.
Condition: Unknown
Due 23 September 1999
Resolved 23 September 1999
Construction/Loadline
Issued 23 September 1999
Resolved
Make permanent repairs to port and stbd sponsons in accordance with the manufacturer's instructions no later than 31DEC99.
Condition: Unknown
Due 23 September 1999
Resolved 23 September 1999
Lifesaving
Issued 23 September 1999
Resolved
Provide life jacket donning placard for the style of life jacket carried onboard.
Condition: Unknown
Due 23 September 1999
Resolved 23 September 1999
Documentation
Issued 25 September 1998
Resolved
Provide and post FCC Staion License.
Condition: Unknown
Due 29 October 1998
Resolved 15 November 1998
Lifesaving
Issued 25 September 1998
Resolved
Prove that current vapor detection system meets UL standard 1110, "marine Combustible Gas Indicators," or be approved by a independent laboratory.
Condition: Unknown
Due 25 September 1998
Resolved 25 September 1998
Fire Fighting
Issued 25 September 1998
Resolved
Place on board 1 B-II protable fore extinguisher.
Condition: Unknown
Due 28 October 1998
Resolved 15 November 1998
Documentation
Issued 25 September 1998
Resolved
Provide and post FCC Safety Certificate.
Condition: Unknown
Due 29 October 1998
Resolved 15 November 1998
Lifesaving
Issued 25 September 1998
Resolved
Properly placard stowage areas for adult and child lifejackets.
Condition: Unknown
Due 29 October 1998
Resolved 15 November 1998
Lifesaving
Issued 25 September 1998
Resolved
Post lifejacket donning placard.
Condition: Unknown
Due 28 October 1998
Resolved 15 November 1998
Lifesaving
Issued 25 September 1998
Resolved
Provide 60' life line for ringlife buoy.
Condition: Unknown
Due 29 October 1998
Resolved 15 November 1998
Lifesaving
Issued 25 September 1998
Resolved
Place vessel name on ring life buoy.
Condition: Unknown
Due 28 October 1998
Resolved 15 November 1998
Lifesaving
Issued 25 September 1998
Resolved
Post emergency broadcast placard.
Condition: Unknown
Due 28 October 1998
Resolved 15 November 1998
Lifesaving
Issued 25 September 1998
Resolved
Post emergency instruction list.
Condition: Unknown
Due 28 October 1998
Resolved 15 November 1998
Navigation
Issued 25 September 1998
Resolved
Place onboard vessel, updated charts, light list, tide tables for area of operation._x001C_ _x001C_ _x001C_
Condition: Unknown
Due 28 October 1998
Resolved 15 November 1998
Fire Fighting
Issued 25 September 1998
Resolved
Place onboard three 2.5 gallon fore buckets, appropriately marked with proper amount of lanyard.
Condition: Unknown
Due 28 October 1998
Resolved 15 November 1998
Engineering
Issued 25 September 1998
Resolved
Prove proper operation of vapor detection system.
Condition: Unknown
Due 28 October 1998
Resolved 15 November 1998
Engineering
Issued 25 September 1998
Resolved
Provide calibration procedures for vapor detection system.
Condition: Unknown
Due 28 October 1998
Resolved 15 November 1998
Fire Fighting
Issued 25 September 1998
Resolved
Prove operation of visual and audible alarm for fixed fire system.
Condition: Unknown
Due 28 October 1998
Resolved 15 November 1998
Fire Fighting
Issued 25 September 1998
Resolved
Post activation procedures for fixed fire system, including the securing ofpower and natural ventilation.
Condition: Unknown
Due 28 October 1998
Resolved 15 November 1998