CAPTAIN BLACK

CAPTAIN BLACK is a 1974 passenger vessel (inspected). The Coast Guard has recorded 91 inspections since 1980, most recently in October 2025, along with 217 deficiencies, 1 operational control and 1 casualty investigation in 2017.

Records from 1980 to 2025. Most recent: inspection, 30 October 2025.

Built
1974
Last inspected
30 October 2025
Documentation
Valid · documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

WDL7645
Flag
UNITED STATES
367177720
Maury page id
psix-47905

Inspections, by type

…with no type recorded12
Years with a record 42 calendar years (1980–2025)
The 91 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Passenger Ship class in Maury's sources begin in 1977.

Documentation record

Registered dimensions (L × B × D)50.5 ft × 17.6 ft × 7.0 ft
Registered tonnagegross 45 / net 30
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
BuilderROSE CRAFT INC · HARKERS ISLAND, NC, UNITED STATES · built 1974
Hull materialWood
PropulsionDiesel Reduction
Hull shapeNot recorded
Hull configurationNot recorded
Hailing portPANAMA CITY BEACH, FL
Trade endorsementsCoastwise, unrestricted, Fishery
DocumentationValid · issued 29 January 2026 · expires 31 January 2027
Service, as the file records itPassenger (Inspected)
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it45 - Regulatory (Subpart C or D), Gross Ton
30 - Regulatory (Subpart C or D), Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 September 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.

Radio station licence

WDL7645MMSI 367177720 · active · compulsorily equipped · granted 12 September 2020, expires 12 September 2030 · licensed under a name not among this hull’s recorded names (not shown)
WDF5241MMSI 367460950 · expired · compulsorily equipped · granted 16 July 2010, cancelled 19 September 2020
WDD6795MMSI 367177720 · expired · compulsorily equipped · granted 4 April 2007, cancelled 10 June 2017
WCX3200MMSI not assigned · expired · voluntarily equipped · granted 19 March 1997, cancelled 20 May 2007
FCC Universal Licensing System ship-station file of 6 September 2026, matched to this hull on its US Official Number. Status and dates are the file’s own. The licensee is not read from the file and is not shown. A lapsed licence’s MMSI is still the number the vessel transmitted under while it was valid.

Inspection history · 91

30 October 2025 Administrative Inspection · Annual Inspection
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 8259158
3 September 2025 Administrative Inspection · Special Consideration
Administrative · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 8226100
3 June 2025 Type not recorded
No type recorded · USCGC COBIA (WPB 87311) · USCG Heartland District (CGD-H) · Activity 8156600
26 March 2025 Examination of Repairs · Administrative Inspection
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 8100142
20 February 2025 Administrative Inspection · Internal Structural Exam · Drydock Exam
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 8082193
29 October 2024 Administrative Inspection · Annual Inspection
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 8026934
19 October 2023 Administrative Inspection · Special
Administrative · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 7811274
10 October 2023 Deficiency Check · COI Inspection · Administrative Inspection · DAPI Audit
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 7805783
31 May 2023 In-Service Inspection
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 7701476
26 January 2023 Internal Structural Exam · Drydock Exam
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 7627439
13 October 2022 Annual Inspection
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 7576477
22 July 2022 In-Service Inspection
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 7513705
27 October 2021 Deficiency Check · Annual Inspection · Administrative Inspection
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 7341187
23 July 2021 In-Service Inspection
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 7264320
12 April 2021 Internal Structural Exam · Drydock Exam · Administrative Inspection
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 7173690
20 October 2020 Administrative Inspection · Annual Inspection · DAPI Audit
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 7080706
5 May 2020 Administrative Inspection
Administrative · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 6948396
17 September 2019 In-Service Inspection · Administrative Inspection
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 6814335
12 September 2019 Annual Inspection · Administrative Inspection
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 6810157
25 February 2019 Hull Examination · Administrative Inspection
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 6631839
3 August 2018 COI Inspection · Administrative Inspection · DAPI Audit
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 6499703
17 June 2017 Type not recorded
No type recorded · Sector Mobile · USCG Heartland District (CGD-H) · Activity 6183123
20 March 2017 Administrative Inspection · Examination of Repairs · Internal Structural Exam · Hull Examination
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 6108063
21 April 2016 Administrative Inspection · DAPI Audit · COI Inspection · Deficiency Check
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 5859388
2 September 2015 Administrative Inspection · Deficiency Check · DAPI Audit · Annual Inspection
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 5233074
27 August 2014 Deficiency Check
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 4967293
3 May 2012 Deficiency Check · Annual Inspection
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 4298477
9 July 2009 Deficiency Check
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 3529370
28 January 2009 Hull Examination · Deficiency Check
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 3397214
14 May 2008 Deficiency Check
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 3206621
8 May 2008 Deficiency Check
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 3200789
28 April 2008 Type not recorded
No type recorded · Station Pensacola · USCG Heartland District (CGD-H) · Activity 3194580
9 April 2008 Annual Inspection
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 3167114
2 May 2007 Deficiency Check
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 2910720
4 April 2007 Annual Inspection
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 2901666
6 February 2007 Hull Examination · Examination of Repairs · Deficiency Check
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 2867646
28 March 2006 Deficiency Check
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 2622488
21 March 2006 COI Inspection
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 2606157
6 October 2005 Damage Survey
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 2508988
16 September 2005 Damage Survey
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 2494319
22 February 2005 Deficiency Check · Annual Inspection
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 2297073
17 February 2005 Hull Examination · Internal Structural Exam
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 2294251
30 March 2004 Annual Inspection
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 2030639
18 February 2004 Hull Examination
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 2010228
28 July 2003 Examination of Repairs · Damage Survey
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1872980
3 June 2003 Annual Inspection
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1798844
5 August 2002 Deficiency Check
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1671085
9 July 2002 Annual Inspection
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1632462
1 March 2002 Hull Examination
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1480891
13 August 2001 Type not recorded
No type recorded · CGC POINT LOBOS · USCG Heartland District (CGD-H) · Activity 1521166
1 May 2001 Deficiency Check
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1063268
18 April 2001 COI Inspection
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1063855
27 March 2001 Type not recorded
No type recorded · CGC POINT LOBOS · USCG Heartland District (CGD-H) · Activity 1521137
30 March 2000 Re-Inspection
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1050076
23 March 2000 Hull Examination
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1438991
22 April 1999 Re-Inspection
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1433474
8 March 1999 Plan Review "T" Boat
Administrative · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1349959
23 April 1998 Hull Examination · COI Inspection
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1436102
2 July 1997 Administrative
Administrative · MSO Mobile · USCG Heartland District (CGD-H) · Activity 780437
2 May 1997 Deficiency Check
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1097299
25 March 1997 Hull Examination · Re-Inspection
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1419755
29 March 1996 Re-Inspection · Deficiency Check
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1460858
1 December 1995 Deficiency Check
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 881353
25 October 1995 Deficiency Check
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1192906
20 September 1995 Hull Examination
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1447477
3 April 1995 COI Inspection · Deficiency Check
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1431502
7 April 1994 Re-Inspection · Deficiency Check
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1169212
3 March 1994 Hull Examination
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 853150
21 July 1993 Deficiency Check
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 848692
21 April 1993 Deficiency Check
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1143062
14 April 1993 Re-Inspection
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 832881
23 April 1992 COI Inspection
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1266131
11 March 1992 Hull Examination
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 950242
18 February 1992 Type not recorded
No type recorded · MSO Mobile · USCG Heartland District (CGD-H) · Activity 947739
19 June 1991 Deficiency Check
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 908131
24 April 1991 Re-Inspection
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1211702
28 March 1991 Hull Examination
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 934912
12 April 1990 Re-Inspection
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1233873
26 March 1990 Hull Examination
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1234190
14 July 1989 Deficiency Check
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1205215
20 April 1989 COI Inspection · Hull Examination
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1032139
7 April 1988 Re-Inspection
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1204612
29 March 1988 Hull Examination
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 893353
8 April 1987 Re-Inspection · Hull Examination
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1313751
11 April 1986 Credit Drydock · COI Inspection
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1003144
1 April 1985 Type not recorded
No type recorded · MSO Mobile · USCG Heartland District (CGD-H) · Activity 977944
3 May 1984 Type not recorded
No type recorded · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1281256
2 April 1984 Type not recorded
No type recorded · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1284985
4 April 1983 Type not recorded
No type recorded · MSO Mobile · USCG Heartland District (CGD-H) · Activity 966212
12 April 1982 Type not recorded
No type recorded · MSO Mobile · USCG Heartland District (CGD-H) · Activity 963643
14 April 1980 Type not recorded
No type recorded · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1272811

Deficiency record · 217

05 - Radio Communications › N/A - No Subsystem › MF/HF Radio installation
Issued 10 October 2023 Resolved
The vessel must be equipped with the appropriate amount of DSC radios for the route specified on the COI. The HF/SSB radio has been removed. The route requires, at a minimum, 1-VHF and 1-MF radio. The vessel is restricted to not more than 20NM from shore until corrected.
Condition: Improper Installation
Action required: 705 - Other - as specified
Resolved 19 October 2023
Resolution: Vessel re-installed the SSB.
05 - Radio Communications › N/A - No Subsystem › VHF radio installation
Issued 10 October 2023 Resolved
The vessel must have a VHF-DSC radio that is properly installed. The radios must be GPS capable or linked to a GPS.
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 10 November 2023
Resolved 19 October 2023
Resolution: Corrected.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 10 October 2023 Resolved
Emergency instructions shall be posted and/or available for crew. There are no instructions on board containing instructions on what to do in the event of an emergency.
Action required: 60 - Rectify deficiencies prior to movement
Due 10 November 2023
Resolved 19 October 2023
Resolution: Corrected.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 10 October 2023 Resolved
A passenger safety bill must be generated and posted in the cabin and accommodation space.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 10 November 2023
Resolved 19 October 2023
Resolution: Corrected.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 10 October 2023 Resolved
The following operational hazards must be corrected: 1. Distress flare storage location needs to be labeled 2. Emergency light for passenger egress is not working 3. Half of the all-around Anchor light is not working 4. Install circuit breaker filler plates x2
Action required: 50 - Rectify deficiencies w/in 30 days
Due 10 November 2023
Resolved 19 October 2023
Resolution: Corrected.
07 - Fire Safety › N/A - No Subsystem › Fire detection and alarm system
Issued 31 May 2023 Resolved
Inspected small passenger vessels that operate on coastwise or oceans routes must have an interconnected fire detection system installed in an all enclosed areas where passengers and crew have routine access, including accommodation spaces and machinery spaces to be installed by December 27th, 2022. Provide evidence of installation and that the fire-detection system has been approved. Until installed, the vessel is now restricted to a Limited Coastwise route.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 31 May 2023
Resolved 22 June 2023
Resolution: Received photographs from vessel owner [name withheld], of the (01) corrected deficiency for the installed interconnected fire-detection system; satisfactory.
07 - Fire Safety › N/A - No Subsystem › Fire detection and alarm system
Issued 31 May 2023 Resolved
Inspected small passenger vessels with an endorsement for overnight accommodations are required to be equipped with an installed monitoring device(s) to ensure the wakefulness of the assigned watchmen. The vessel is prohibited from carrying overnight passengers until the adequate monitoring device is installed.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 31 May 2023
Resolved 15 June 2023
Resolution: Received photographs from vessel owner [name withheld], of the (01) corrected deficiency for the watchmen monitoring system; satisfactory.
07 - Fire Safety › N/A - No Subsystem › Fixed fire extinguishing installation
Issued 27 October 2021 Resolved
Vessels generator exhaust hose and sewage hoses are resting on the fire boys activation cage. Properly secure loose hoses.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 24 January 2022
Resolution: Exhaust hose and sewage hose were properly secured to the overhead.
07 - Fire Safety › N/A - No Subsystem › Oil accumulation in engine room
Issued 27 October 2021 Resolved
Remove access oil and debris from the port main engine air intakes.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 24 January 2022
Resolution: Oil was cleaned and debris removed from port main engine air intakes.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 27 October 2021 Resolved
The vessels hand dewatering pump should have enough hose to draw suction from bilges and discharge overboard. Provide additional hose for hand pump.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 24 January 2022
Resolution: New hose provided for hand pump.
09 - Working and Living Conditions › 091 - Living Conditions › Medical Equipment
Issued 27 October 2021 Resolved
Vessels first aid kit has expired aspirin. Replace expired aspirin.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 24 January 2022
Resolution: Vessel procured new, valid first aid kit with aspirin included.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 27 October 2021 Resolved
Vessel has only expired alcohol testing strips, replace with valid testing strips.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 24 January 2022
Resolution: Vessel procured four new, valid alcohol test strips
05 - Radio Communications › N/A - No Subsystem › Functional requirements
Issued 27 October 2021 Resolved
Unable to prove operational DSC function of VHF radio. Properly program and demonstrate DSC function.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 24 January 2022
Resolution: Verified programming of VHF-DSC radio with vessel MMSI number and demonstrated DSC function.
07 - Fire Safety › N/A - No Subsystem › Means of escape
Issued 27 October 2021 Resolved
Vessels accommodation escape hatch is unable to be opened from the exterior of the space. Replace or provide a means for both interior & exterior operation.
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 24 January 2022
Resolution: Escape hatch replaced
01 - Certificates & Documentation › 011 - Ships Certificates › Other (certificates)
Issued 20 October 2020 Resolved
Provide proof of valid FCC Station License.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 2 December 2020
Resolution: Master provided proof of valid FCC Station License.
01 - Certificates & Documentation › 011 - Ships Certificates › Other (certificates)
Issued 20 October 2020 Resolved
Provide proof of valid FCC Radio Safety Certificate.
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 2 December 2020
Resolution: Master provided proof of valid FFC Radio Safety Certificate.
11 - Life Saving Appliances › N/A - No Subsystem › Distress flares
Issued 20 October 2020 Resolved
Provide proof of 2 missing red signal flares.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 2 December 2020
Resolution: Masted provided proof of 2 additional red signal flares.
10 - Safety of Navigation › N/A - No Subsystem › Nautical publications
Issued 20 October 2020 Resolved
Provide proof of current tide tables.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 2 December 2020
Resolution: Master provided proof of updated Tide Tables.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 20 October 2020 Resolved
Remove power strip from pilot house.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 2 December 2020
Resolution: Verified that the Master removed power strip from Pilot Hose.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 20 October 2020 Resolved
Remove epoxy from starboard outboard exhaust riser and replace or permanently repair.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 2 December 2020
Resolution: Verified that the Master removed epoxy from the starboard outboard exhaust riser.
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 20 October 2020 Resolved
Provide proof that engine room fireboy is of adequate capacity for the space.
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 2 December 2020
Resolution: Member provided proof that Fireboy was of adequate capacity for engine room space.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 20 October 2020 Resolved
Replace wasted hose fittings on hydraulic steering lines.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 2 December 2020
Resolution: Verified that wasted hose fittings on hydraulic steering lines.
02 - Structural Conditions › N/A - No Subsystem › Beams, frames, floors-op. damage
Issued 20 October 2020 Resolved
Properly fasten port and starboard stern engine room centerline stanchions.
Condition: Damaged By Earlier Event
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 2 December 2020
Resolution: Support beams welded in.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 9 August 2018 Resolved
STBD Engine Alternator sparked and flamed shot out for approximately 5 seconds. Notified vessel rep. that is must be repaired to proper or safe working order.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 9 August 2018
Resolved 18 October 2018
Resolution: Starter replaced; no sparking identified on alternator. Both engines started properly and safely.
Deck/Cargo › Holds/Tanks › Scuttle
Issued 10 May 2016 Resolved
Water tight hatches on main deck need new gasket.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 23 May 2016
Resolved 16 May 2016
Resolution: New gaskets installed and tested.
Navigation › Piloting/Steering › Inland Navigation Rules
Issued 10 May 2016 Resolved
Nav lights, green and stern light were not working.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 23 May 2016
Resolved 16 May 2016
Resolution: New bulbs for lights installed and tested.
Lifesaving › Lifefloat › Floating Electric Waterlight
Issued 10 May 2016 Resolved
Water light has wrong battery for life float.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 23 May 2016
Resolved 16 May 2016
Resolution: Proper battery installed and tested.
Electrical › Electric Supply System (service) › Cable
Issued 10 May 2016 Resolved
Wires and plumbing near generator need proper supports.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 23 May 2016
Resolved 16 May 2016
Resolution: The plumbing and electrical wires were properly supported.
Electrical › Electric Supply System (service) › Cable
Issued 10 May 2016 Resolved
Wires in rudder room need proper supports every 24".
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 23 May 2016
Resolved 16 May 2016
Resolution: Wires in rudder room properly supported.
Accommodation/Occupational Safety › Occupational Safety › Rubbish/Waste Materials
Issued 10 May 2016 Resolved
Need non combustable trash can for cabin area.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 23 May 2016
Resolved 16 May 2016
Resolution: Proper trash can was purchased and onboard.
Construction/Loadline › Structures › Transverse Bulkhead
Issued 10 May 2016 Resolved
Collision bulk head right down center has an unsealed seam. Needs to be sealed for water tight integrity.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 23 May 2016
Resolved 16 May 2016
Resolution: Fwd collision bulkhead was made water tight.
Engineering › Engine Controls (Electric/Electronic) › Circuit Board
Issued 10 May 2016 Resolved
Main engines would not start. Engines need to run for exam and getting underway for drills.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 23 May 2016
Resolved 16 May 2016
Resolution: Repairs were made to both main engines, engines started and operated satisfactorly.
Engineering › Bilge Water Management System › Interface Detector
Issued 7 October 2015 Resolved
Bilge alarm at operating station is not properly working. Repair alarm panel to indicate each space individually.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 21 October 2015
Resolved 21 October 2015
Resolution: Issue resolved to the satisfaction of the marine inspector.
Electrical › Lighting (emergency) › Lighting Fixture
Issued 7 October 2015 Resolved
Emergency lighting is not working. Repair emergency lighting.
Action required: 705 - Other - as specified
Due 21 October 2015
Resolved 21 October 2015
Resolution: Issue resolved to the satisfaction of the marine inspector.
Engineering › Diesel Engine (propulsion/auxiliary-electric) › Exhaust Manifold
Issued 7 October 2015 Resolved
The exhaust for the STBD main had some loose lagging. Repair lagging IAW 182.15-15
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 21 October 2015
Resolved 21 October 2015
Resolution: Issue resolved to the satisfaction of the marine inspector.
Engineering › Diesel Engine (propulsion-reduction gear) › Seal
Issued 7 October 2015 Resolved
Both MDE reduction gears are leaking oil at the pumps. Repair leaks and demonstrate proper operation prior to carrying passengers IAW 46 CFR 182.100.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 21 October 2015
Resolution: Leaks repaired to the satisfaction of attending Marine Inspector.
Fire Fighting › Means of Escape › Blocked
Issued 11 September 2015 Resolved
The forward hatch used for emergency escape is not operable from both sides. Install a means of opening the hatch from both sides in accordance with (IAW) 46CFR179.360
Condition: Design Flaw
Action required: 705 - Other - as specified
Due 11 October 2015
Resolved 7 October 2015
Resolution: Issue resolved to the satisfaction of the marine inspector.
Lifesaving › Lifefloat › Floating Electric Waterlight
Issued 11 September 2015 Resolved
Water light line attached to the life float is not the proper size. The line must be 3/8 and 18 feet in length IAW 46CFR180.175
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 11 October 2015
Resolved 7 October 2015
Resolution: Issue resolved to the satisfaction of the marine inspector.
Deck/Cargo › Mooring/Anchoring › Anchor Shackle
Issued 11 September 2015 Resolved
Anchor shackles were not properly moused. Provide and install a securing mousing device IAW 46CFR184.300. This was fixed on site and verified by MI.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 11 September 2015
Resolved 11 September 2015
Resolution: Issue resolved to the satisfaction of the marine inspector.
Engineering › Steering Gear System › Ram
Issued 11 September 2015 Resolved
The aft steering ram was leaking hydraulic fluid from the seal. Repair IAW 46CFR176.814.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 11 October 2015
Resolved 7 October 2015
Resolution: Issue resolved to the satisfaction of the marine inspector.
Engineering › Steering Gear System › Cable
Issued 11 September 2015 Resolved
There was a grounding wire in aft steering that was not properly bonded. Bond wire to the proper metal plating IAW 46CFR183.220
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 11 October 2015
Resolved 7 October 2015
Resolution: Issue resolved to the satisfaction of the marine inspector.
Engineering › Bilge Water Management System › Piping
Issued 11 September 2015 Resolved
The bilge piping throughout the vessel was constructed of flexible hose and PVC pipes. Replace all piping or hose with approved material IAW 46CFR182.520
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 11 October 2015
Resolved 7 October 2015
Resolution: Issue resolved to the satisfaction of the marine inspector.
Engineering › Bilge Water Management System › Not Operational
Issued 11 September 2015 Resolved
Bilge pump switches at the operating station did not have an audible means of operation. Install audible alarm IAW 46CFR182.530.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 4 October 2015
Resolved 7 October 2015
Resolution: Issue resolved to the satisfaction of the marine inspector.
Engineering › Bilge Water Management System › Not Installed
Issued 11 September 2015 Resolved
There was no high water level alarm in the lazarette or berthing area. Install high level alarms for the said spaces IAW 46CFR182.530.
Condition: Invalid
Action required: 705 - Other - as specified
Due 11 October 2015
Resolved 7 October 2015
Resolution: Issue resolved to the satisfaction of the marine inspector.
Electrical › Electrical Distribution System (service) › Outlet Box
Issued 11 September 2015 Resolved
There was a receptacle at the operating station that was not properly covered. Provide a means to cover the receptacle to prevent electrical hazard IAW 46CFR183.01-5
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 11 October 2015
Resolved 7 October 2015
Resolution: Issue resolved to the satisfaction of the marine inspector.
Electrical › Lighting (service) › Lighting Fixture
Issued 11 September 2015 Resolved
There was a light on the topside that was not properly covered. Provide a means to cover the receptacle to prevent electrical hazard IAW 46CFR183.01-5
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 11 October 2015
Resolved 7 October 2015
Resolution: Issue resolved to the satisfaction of the marine inspector.
Electrical › Electrical Distribution System (service) › Wiring
Issued 11 September 2015 Resolved
There were dead ended wires under the seat on the port side of the main operating station. Properly remove or cap wires to prevent electrical hazard IAW 46CFR183.01-5.
Condition: Invalid
Action required: 705 - Other - as specified
Due 11 October 2015
Resolved 7 October 2015
Resolution: Issue resolved to the satisfaction of the marine inspector.
Engineering › Steering Gear System › Hydraulic Hose
Issued 11 September 2015 Resolved
There was a hydraulic block with sharp screws exposed under the console in the main operation station that was loosely resting on top of other wires. Properly secure the hydraulic block so damage to wires and lines can be prevented IAW 46CFR182.100.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 11 October 2015
Resolved 7 October 2015
Resolution: Issue resolved to the satisfaction of the marine inspector.
Communications › Alarms/Indicators › Engine RPM Gauge/Indicator
Issued 11 September 2015 Resolved
The STBD RPM gauge was not properly working on the main operating station. Fix or remove the STBD RPM gauge IAW 46CFR182.410 and 46CFR182.20-5.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 11 October 2015
Resolved 7 October 2015
Resolution: Issue resolved to the satisfaction of the marine inspector.
Electrical › Electrical Distribution System (service) › Wiring
Issued 11 September 2015 Resolved
There were dead ended wires for an unused video camera system on top of the console in the main operating station. Remove the dead ended wires and camera system to prevent electrical hazard in accordance with IAW 46CFR183.01.5
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 11 October 2015
Resolved 7 October 2015
Resolution: Issue resolved to the satisfaction of the marine inspector.
Documentation › Manuals/Policy Documentation › Emergency Instructions
Issued 11 September 2015 Resolved
There were no emergency instructions posted on the main operating station. Install emergency instructions on the main operating station IAW 46CFR185.510.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 11 October 2015
Resolved 7 October 2015
Resolution: Issue resolved to the satisfaction of the marine inspector.
Engineering › Bilge Water Management System › Pump
Issued 11 September 2015 Resolved
Bilge pump for aft steering was not properly working. Repair bilge pump to operating standard IAW 46CFR182.520.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 11 October 2015
Resolved 7 October 2015
Resolution: Issue resolved to the satisfaction of the marine inspector.
Documentation › Certificates/Documents › FCC Safety Radiotelephony Certificate
Issued 11 September 2015 Resolved
The FCC radio safety certificate was not signed by the technician. Have the technician sign and validate the safety certificate and provide the radio log filled out by the technician IAW 47CFR80.409 and 47CFR80.903.
Condition: Invalid
Action required: 705 - Other - as specified
Due 11 October 2015
Resolved 7 October 2015
Resolution: Issue resolved to the satisfaction of the marine inspector.
Operations/Management › Drug and Alcohol Testing › Proof of Enrollment
Issued 11 September 2015 Resolved
The deckhand was not added to the company’s DAPI letter. Add all hired members that work for the vessel into the company’s DAPI program as well as a letter showing enrollment IAW 46CFR16.210.
Condition: Invalid
Action required: 705 - Other - as specified
Due 11 October 2015
Resolved 7 October 2015
Resolution: Issue resolved to the satisfaction of the marine inspector.
Operations/Management › Drug and Alcohol Testing › EAP Training Requirements
Issued 11 September 2015 Resolved
There was no record of crew training for DAPI on board. Provide documentation for all supervisory personnel and crew members have received appropriate training IAW 46CFR16.230.
Condition: Invalid
Action required: 705 - Other - as specified
Due 11 October 2015
Resolved 7 October 2015
Resolution: Issue resolved to the satisfaction of the marine inspector.
Operations/Management › Drills/Instruction › Not Conducted
Issued 11 September 2015 Resolved
Unable to verify drills and training competency of all crew members at this time. Perform and demonstrate proficiency in all required drills prior to carrying passenger 46CFR185.520.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 23 October 2015
Resolved 23 October 2015
Resolution: Item resolved to the satisfaction of the Marine Inspector.
Operations/Management › Navigation Safety › Carriage of Charts and Publications
Issued 11 September 2015 Resolved
The Navigation Rule was outdated. Obtain an updated Navigation Rule book IAW 33CFR88.05.
Condition: Invalid
Action required: 705 - Other - as specified
Resolved 7 October 2015
Resolution: Issue resolved to the satisfaction of the marine inspector.
Operations/Management › Navigation Safety › Carriage of Charts and Publications
Issued 11 September 2015 Resolved
Did not provide updated charts for inspection. Obtain and make available for inspection updated charts IAW 46CFR184.420.
Condition: Invalid
Action required: 705 - Other - as specified
Resolved 7 October 2015
Resolution: Issue resolved to the satisfaction of the marine inspector.
Engineering › Bilge Water Management System › Pump
Issued 11 September 2015 Resolved
Portable bilge pump hose did not reach all compartments. Provide a portable bilge pump that is able to pump water out from all compartments IAW 46CFR182.25-10
Condition: Improper Installation
Action required: 705 - Other - as specified
Resolved 7 October 2015
Resolution: Issue resolved to the satisfaction of the marine inspector.
Fire Fighting › Fixed Fire Detection System › UL 217 Approval
Issued 11 September 2015 Resolved
Smoke detector on accommodation spaces not CG approved. Provide an UL 217 approved smoke detector in all accommodation spaces IAW46CFR181.400.
Condition: Invalid
Action required: 705 - Other - as specified
Resolved 7 October 2015
Resolution: Issue resolved to the satisfaction of the marine inspector.
Electrical › Electrical Distribution System (service) › Wiring
Issued 11 September 2015 Resolved
Single wires not properly covered by an electrical conduit inside the electrical room. Provide proper insulation for cables IAW 46CFR183.10-20.
Condition: Improper Installation
Action required: 705 - Other - as specified
Resolved 7 October 2015
Resolution: Issue resolved to the satisfaction of the marine inspector.
Construction/Loadline › Structures › Machinery Space Opening
Issued 11 September 2015 Resolved
The FWD bulkhead was not vapor tight due to several holes leading to the accommodation space. Provide a means to make bulkhead vapor tight IAW 46CFR182.35-1.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 17 September 2015
Resolved 7 October 2015
Resolution: Issue resolved to the satisfaction of the marine inspector.
Accommodation/Occupational Safety › Occupational Safety › Portable Electric Equipment/Appliances
Issued 11 September 2015 Resolved
There was an AC pump, and oil change pump, and water pump not properly secured in the engine room. Mount all pumps and loose gear in the engine room IAW 46CFR182.100.
Condition: Improper Installation
Action required: 705 - Other - as specified
Resolved 7 October 2015
Resolution: Issue resolved to the satisfaction of the marine inspector.
Engineering › Diesel Engine (auxiliary) › Valve
Issued 11 September 2015 Resolved
The solenoids on both MDE were not properly secured and the one in the STBD MDE had a broken wire. Properly mount both solenoids and fixe the broken wire on the STBD MDE solenoid IAW 46CFR183.01-5
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Resolved 7 October 2015
Resolution: Issue resolved to the satisfaction of the marine inspector.
Pollution Prevention/Response › Prevention Equipment › Sewage System Piping
Issued 11 September 2015 Resolved
The sewage tank was not properly vented. Provide proper ventilation for the sewage tank IAW 33CFR159.61.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Resolved 7 October 2015
Resolution: Issue resolved to the satisfaction of the marine inspector.
Documentation › Certificates/Documents › Certificate of Inspection
Issued 11 September 2015 Resolved
COI and radio safety certificates were not posted. Post the COI, radio safety certificate and all required documents in a conspicuous space visible to all passengers IAW 46CFR176.302.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Resolved 7 October 2015
Resolution: Issue resolved to the satisfaction of the marine inspector.
Lifesaving › Embarkation Appliances/Stations › Accessability
Issued 11 September 2015 Resolved
There was not a proper means or ladder for rescuing MOB on board. Provide a ladder to ensure that MOB can be safely recovered IAW 180.210.
Condition: Invalid
Action required: 705 - Other - as specified
Resolved 7 October 2015
Resolution: Issue resolved to the satisfaction of the marine inspector.
Electrical › Electrical Distribution System (service) › Switchboard
Issued 11 September 2015 Resolved
The switchboards were not properly protected. Switch board must be fitted with drip shields IAW 46CFR183.10-15.
Condition: Improper Installation
Action required: 705 - Other - as specified
Resolved 7 October 2015
Resolution: Issue resolved to the satisfaction of the marine inspector.
Engineering › Diesel Engine (auxiliary) › Piping (exhaust)
Issued 11 September 2015 Resolved
The port MDE had an oil leak on the shift level on top of the port reduction gear. Fix this leak and all other oil and exhaust leaks in the engine room IAW 46CFR182.100.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 7 October 2015
Resolution: Issue resolved to the satisfaction of the marine inspector.
Documentation › Certificates/Documents › Permit, Other
Issued 11 September 2015 Resolved
Vessel Master’s FCC operator permit was expired. Renew FCC radio operator permit IAW 47CFR80.401.
Condition: Invalid
Action required: 705 - Other - as specified
Resolved 7 October 2015
Resolution: Issue resolved to the satisfaction of the marine inspector.
Electrical › Electric Supply System (service) › Battery Installation
Issued 11 September 2015 Resolved
Battery in engine room was not properly secured. Secure battery within battery box to prevent movement IAW 46CFR183.354.
Condition: Improper Installation
Action required: 705 - Other - as specified
Resolved 7 October 2015
Resolution: Issue resolved to the satisfaction of the marine inspector.
Construction/Loadline › Hull › Transverse Frame
Issued 11 September 2015 Resolved
Provide repair proposal to repair frames on STBD side. The following frames showed significant rotting on the STBD side of the engine room: the 2nd frame away from aft bulkhead, and 3rd and 5th frames away from the FWD bulkhead. Repair IAW 46CFR176.802.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Resolved 7 October 2015
Resolution: Issue resolved to the satisfaction of the marine inspector.
Electrical › Electric Generation Source (service) › Generator
Issued 11 September 2015 Resolved
The generator was not derated to 80%. Derate generated to 80% IAW 46CFR183.320
Condition: Improper Installation
Action required: 705 - Other - as specified
Resolved 7 October 2015
Resolution: Issue resolved to the satisfaction of the marine inspector.
Electrical › Electric Generation Source (service) › Circuit Breaker
Issued 11 September 2015 Resolved
The generator switch breaker was not properly installed. The switch breaker for the generator needs to be at 115% IAW 46CFR183.320.
Condition: Improper Installation
Action required: 705 - Other - as specified
Resolved 7 October 2015
Resolution: Issue resolved to the satisfaction of the marine inspector.
Documentation › Certificates/Documents › Certificate of Inspection
Issued 2 September 2015 Resolved
Vessel failed to conduct its annual inspection within its time period. Conduct annual inspections IAW 46 CFR 176.500.
Condition: Invalid
Action required: 705 - Other - as specified
Due 1 October 2015
Resolved 7 October 2015
Resolution: Issue resolved to the satisfaction of the marine inspector.
Engineering › Diesel Engine (auxiliary) › Waste Heat Recovery
Issued 3 May 2012 Resolved
Make repairs to deteriorated exhaust hose serving generator set as per 46 CFR 176.800.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 3 June 2012
Resolved 5 June 2012
Resolution: Replaced hose
Electrical › Electrical Distribution System (service) › Junction Box
Issued 3 May 2012 Resolved
Install box connector on the ship to shore switch to prevent damage to wire installation caused by vibration as per 46 CFR 183.390 (b) and 183.05-50.
Action required: 705 - Other - as specified
Due 3 June 2012
Resolved 5 June 2012
Operations/Management › Bilge/Bilge System Management › Control of Excess Water
Issued 3 May 2012 Resolved
Prove proper operation of portable hand bilge pump as per 46 CFR 182.520 (b).
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 3 June 2012
Resolved 5 June 2012
Resolution: Purchased new pump
Lifesaving › Lifefloat › Serviceable
Issued 22 July 2009 Resolved
Repair or replace lifefloat. Vessel is restricted to a lakes, bays, and sounds route until item is cleared.
Action required: 705 - Other - as specified
Due 22 August 2009
Resolved 23 July 2009
Resolution: Lifefloat was replaced with a 22-person capacity lifefloat.
Engineering › Sea-water System (primary cooling) › Valve
Issued 28 January 2009 Resolved
Make gate valves on engine seawater intakes available for inspection.
Action required: 705 - Other - as specified
Resolved 18 February 2009
Resolution: Sea valves inspected satisfactorily.
Engineering › Shafting/Propeller Arrangements › Strut Bearing
Issued 28 January 2009 Resolved
Install screws and cutlass bearing and make ready for inspection.
Action required: 705 - Other - as specified
Resolved 18 February 2009
Resolution: Props and cutlass bearings inspected satisfactorily.
Construction/Loadline › Hull › Bracket
Issued 28 January 2009 Resolved
Make repairs to gusset on second frame aft of the forward engine room bulkhead starboard side to properly secure bottom frame to side frame.
Action required: 705 - Other - as specified
Resolved 18 February 2009
Resolution: Additional gusset added and secured frames.
Lifesaving › Lifebuoys › Markings (ship name/port)
Issued 9 April 2008 Resolved
Renew the retro reflective tape on the ring buoy as per 46 CFR 180.70.
Due 9 May 2008
Resolved 8 May 2008
Resolution: Tape renewed.
Lifesaving › Lifebuoys › Self-igniting Lights
Issued 9 April 2008 Resolved
Renew the lanyard on the ring buoy floating water light as per 46 CFR 180.70.
Due 9 May 2008
Resolved 8 May 2008
Resolution: Lanyard renewed.
Communications › Radio Communications › EPIRB
Issued 9 April 2008 Resolved
Renew EPIRB battery as per 46 CFR 185.728.
Due 9 May 2008
Resolved 8 May 2008
Resolution: EPIRB renewed.
Electrical › Electric Generation Source (service) › Overcurrent Device
Issued 9 April 2008 Resolved
Prove that the generator has been derated to 80% of the full load rating as per 46 CFR 183.320.
Due 9 May 2008
Resolved 14 May 2008
Resolution: Generator was deratted.
Electrical › Electrical Distribution System (service) › Junction Box
Issued 9 April 2008 Resolved
Install a blank in the distribution panel located in the starboard storage closet as per 46 CFR 183.330.
Due 9 May 2008
Resolved 8 May 2008
Resolution: Blank added.
Electrical › Electric Generation Source (service) › Panelboard
Issued 9 April 2008 Resolved
Secure cover to the volt meter as per 46 CFR 183.330.
Due 9 May 2008
Resolved 8 May 2008
Resolution: Cover secured.
Lifesaving › Lifefloat › Painter
Issued 9 April 2008 Resolved
Renew the life float painter as per 46 CFR 180.175.
Due 9 May 2008
Resolved 8 May 2008
Resolution: Painter renewed.
Lifesaving › Lifefloat › Serviceable
Issued 9 April 2008 Resolved
Patch life float with approved coating as per 46 CFR 176.800.
Due 9 May 2008
Resolved 8 May 2008
Resolution: Life float patched.
Lifesaving › Lifejacket/PFD (General) › Condition
Issued 9 April 2008 Resolved
Renew 3 life jackets as per 46 CFR 180.71.
Due 9 May 2008
Resolved 8 May 2008
Resolution: Lifejackets renewed.
Lifesaving › Hand Flares › Storage
Issued 9 April 2008 Resolved
Provide a portable bright color watertight container for the flares and stencil the container as per 46 CFR 185.614.
Due 9 May 2008
Resolved 8 May 2008
Resolution: Portable container provided.
Communications › Radio Communications › Radiotelephone Transceiver (2-27.5 MHz)
Issued 9 April 2008 Resolved
Demonstrate proper operation of the single side band radio as per 47 CFR 80.905.
Due 9 May 2008
Resolved 8 May 2008
Resolution: Single side band proved operational
Navigation › Piloting/Steering › Tide/Tidal Current Tables
Issued 9 April 2008 Resolved
Provide current copy of current tables as per 46 CFR 184.420.
Due 9 May 2008
Resolved 8 May 2008
Resolution: Current copy provided.
Accommodation/Occupational Safety › Occupational Safety › Portable Electric Equipment/Appliances
Issued 9 April 2008 Resolved
Demonstrate proper operation of the portable light at the operating station as per 46 CFR 183.430.
Due 9 May 2008
Resolved 14 May 2008
Resolution: Portable light provided.
Documentation › Manuals/Policy Documentation › Emergency Instructions
Issued 5 April 2007 Resolved
Provide an Emergency Broadcast Placard in accordance with 46 CFR 184.506.
Action required: 705 - Other - as specified
Due 5 May 2007
Resolved 2 May 2007
Resolution: Provided an Emergency Broadcast Placard in accordance with 46 CFR 184.506.
Documentation › Certificates/Documents › FCC SSL
Issued 5 April 2007 Resolved
[withheld — contains personal information; the deficiency system, dates, and resolution status are shown above]
Action required: 705 - Other - as specified
Due 5 May 2007
Resolved 2 May 2007
Resolution: [withheld — contains personal information; the deficiency system, dates, and resolution status are shown above]
Accommodation/Occupational Safety › Occupational Safety › Guards for Exposed Hazards
Issued 5 April 2007 Resolved
Provide machinery guards over rotating machinery on both main engines and the ships service generator in accordance with 46 CFR 177.960.
Action required: 705 - Other - as specified
Due 5 May 2007
Resolved 2 May 2007
Resolution: Provided machinery guards over rotating machinery on both main engines and the ships service generator in accordance with 46 CFR 177.960.
Engineering › Fuel Oil Service System › Hose
Issued 5 April 2007 Resolved
Tighten the fuel connections on both fuel tank supply and return lines in accordance with 46 CFR 182.455.
Action required: 705 - Other - as specified
Due 5 May 2007
Resolved 2 May 2007
Resolution: Tightened the fuel connections on both fuel tank supply and return lines in accordance with 46 CFR 182.455.
Accommodation/Occupational Safety › Occupational Safety › Guards for Exposed Hazards
Issued 5 April 2007 Resolved
Provide a cover for the generator starting battery box in accordance with 46 CFR 183.354.
Action required: 705 - Other - as specified
Due 5 May 2007
Resolved 2 May 2007
Resolution: Provided a cover for the generator starting battery box in accordance with 46 CFR 183.354.
Electrical › Electric Generation Source (service) › Panelboard
Issued 5 April 2007 Resolved
Prove proper operation of the frequency meter for the generator in accordance with 46 CFR 183.320.
Action required: 705 - Other - as specified
Due 5 May 2007
Resolved 2 May 2007
Resolution: Proved proper operation of the frequency meter for the generator in accordance with 46 CFR 183.320.
Electrical › Electric Supply System (service) › Cable
Issued 5 April 2007 Resolved
Remove the dead-end cable that leads to an old battery charger in accordance with 46 CFR 176.800.
Action required: 705 - Other - as specified
Due 5 May 2007
Resolved 2 May 2007
Resolution: Removed the dead-end cable that lead to an old battery charger in accordance with 46 CFR 176.800.
Electrical › Electric Generation Source (service) › Generator
Issued 5 April 2007 Resolved
Prove the ships service generator has been derated in accordance with 46 CFR 183.320.
Action required: 705 - Other - as specified
Due 5 May 2007
Resolved 2 May 2007
Resolution: Proved the ships service generator has been derated in accordance with 46 CFR 183.320.
Stability › Watertight Integrity › General
Issued 6 February 2007 Resolved
Prove proper operation of both watertight hatches for the lazarette in accordance with 46 CFR 179.360.
Due 6 February 2007
Resolved 15 February 2007
Resolution: Both hatches were rebuilt.
Engineering › Shafting/Propeller Arrangements › Bearing
Issued 6 February 2007 Resolved
Replace the port and starboard strut bearing and the starboard intermediate bearing in accordance with 46 CFR 182.200.
Due 7 February 2007
Resolved 15 February 2007
Resolution: The bearing were all replaced.
Stability › Watertight Integrity › General
Issued 6 February 2007 Resolved
Properly secure the starboard watertight hatch lid to the vessel in accordance with 46 CFR 179.360.
Due 7 February 2007
Resolved 15 February 2007
Resolution: The hatch was properly secured to the vessel.
Stability › Watertight Integrity › General
Issued 6 February 2007 Resolved
Make all sea valves ready for inspection in accordance with 46 CFR 176.610.
Due 6 February 2007
Resolved 15 February 2007
Resolution: All of the valve were inspected with satisfactory results.
Construction/Loadline › Hull › Hull Plating
Issued 6 February 2007 Resolved
Make proper repairs to the port chine forward area as discussed by gouging and reglassing in accordance with NVIC 8-87.
Due 6 February 2007
Resolved 15 February 2007
Resolution: Repairs were made by the owner and inspected with satisfactory results.
Documentation › Logs/Records › Maneuvering Performance Test Results
Issued 21 March 2006 Resolved
Provide for review bridge log as required by 46 CFR 185.520.
Action required: 705 - Other - as specified
Due 21 April 2006
Resolved 28 March 2006
Resolution: Provided Bridge Log.
Navigation › Piloting/Steering › Coast Guard Light List
Issued 21 March 2006 Resolved
Provide Coast Guard light list as required by 46 CFR 184.420.
Action required: 705 - Other - as specified
Due 21 April 2006
Resolved 28 March 2006
Resolution: Provided current light list.
Navigation › Piloting/Steering › Magnetic Compass
Issued 21 March 2006 Resolved
Provide and prove operation of light for magnetic compass ias required by 46 CFR 184.402.
Action required: 705 - Other - as specified
Due 21 April 2006
Resolved 28 March 2006
Resolution: Provided light for the magnetic compass.
Navigation › Collision/Grounding Avoidance › Navigation Lights
Issued 21 March 2006 Resolved
Repair and prove operation of anchor light as required by 46 CFR 183.420.
Action required: 705 - Other - as specified
Due 21 April 2006
Resolved 28 March 2006
Resolution: Proved proper operation of anchor light.
Lifesaving › Lifefloat › Paddle
Issued 21 March 2006 Resolved
Attach paddles to lifefloat in accordance with 46 CFR 180.200.
Action required: 705 - Other - as specified
Due 21 April 2006
Resolved 28 March 2006
Resolution: Properly attached paddles to lifefloat.
Lifesaving › Lifefloat › Float-free Link
Issued 21 March 2006 Resolved
Provide and install properly sized weak link for lifefloat float-free arrangement as required by 46 CFR 180.130.
Action required: 705 - Other - as specified
Due 21 April 2006
Resolved 28 March 2006
Resolution: Provided correct size weak link on the lifefloat.
Stability › Watertight Integrity › General
Issued 21 March 2006 Resolved
Repair and prove operation of access handle to starboard lazarette deck hatch as per 46 CFR 171.124.
Action required: 705 - Other - as specified
Due 21 April 2006
Resolved 28 March 2006
Resolution: Proved proper operation of bomar hatch handle on starboard lazarette hatch.
Accommodation/Occupational Safety › Occupational Safety › Guards for Exposed Hazards
Issued 21 March 2006 Resolved
Provide proper guards for rotating machinery in the engine room as required by 46 CFR 177.960.
Action required: 705 - Other - as specified
Due 21 April 2006
Resolved 28 March 2006
Resolution: Provided proper guards for rotating machinery in the engine room.
Fire Fighting › Remote Fuel Shutoff › General
Issued 21 March 2006 Resolved
Provide two means of shutting off fuel supply in accordance with 46 CFR 182.20-40(b)(3).
Action required: 705 - Other - as specified
Due 21 April 2006
Resolved 28 March 2006
Resolution: Provided two means of shutting off fuel supply.
Fire Fighting › Ventilation Systems › Ducts
Issued 10 March 2005 Resolved
Repair ventilation closures IAW 46 CFR 182.465.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 10 March 2005
Resolution: Closures were renewed.
Lifesaving › Buoyant Apparatus
Issued 30 March 2004 Resolved
Demonstrate proper operation of the waterlight for the lifefloat per 46 CFR 180.150(f)(4)
Action required: 701 - Prior to carriage of passengers/cargo
Due 30 March 2004
Resolved 30 March 2004
Resolution: Waterlight was replaced and tested satisfactorily.
Fire Fighting › Fixed Gas Fire Extinguishing System
Issued 3 June 2003 Resolved
Repair pre-engineered fixed gas emergency shutdown which was inoperable during test/activation as required by 46 CFR 181.420. LEGACY COMPONENT DESC: Operating Controls
Condition: Unknown
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 3 June 2003
Documentation › Certificates/Documents
Issued 9 July 2002 Resolved
Provide FCC safety certificate. LEGACY COMPONENT DESC: FCC safety certificate
Due 9 August 2002
Resolved 5 August 2002
Resolution: Owner provided documentation, FCC Safety Certificate
Engineering › Sea-water System (primary cooling) › Piping
Issued 9 July 2002 Resolved
Leak in salt water cooling line on port main engine at aft bulkhead.
Due 9 July 2002
Resolved 9 July 2002
Engineering › Shafting/Propeller Arrangements
Issued 26 February 2002 Resolved
Replace strut bearings. LEGACY COMPONENT DESC: Strut Bearing
Action required: 705 - Other - as specified
Due 28 March 2002
Resolved 1 March 2002
Engineering › Shafting/Propeller Arrangements
Issued 26 February 2002 Resolved
Replace stern tube bearings. LEGACY COMPONENT DESC: Stern Tube Bearing
Action required: 705 - Other - as specified
Due 28 March 2002
Resolved 1 March 2002
Construction/Loadline › Structures
Issued 26 February 2002 Resolved
Make engine room aft bulkhead airtight were exhaust for main diesel engines penetrates bulkhead. LEGACY COMPONENT DESC: Transverse Bulkhead
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 28 March 2002
Resolved 1 March 2002
Electrical › Electric Generation Source (service)
Issued 26 February 2002 Resolved
Replace flexible hose clamps on generator exhaust in aft steering compartment. LEGACY COMPONENT DESC: Generator
Action required: 705 - Other - as specified
Due 28 March 2002
Resolved 1 March 2002
Construction/Loadline › Hull
Issued 26 February 2002 Resolved
Replace keel bolt on frame eight. LEGACY COMPONENT DESC: Keel
Action required: 705 - Other - as specified
Due 28 March 2002
Resolved 1 March 2002
Construction/Loadline › Hull
Issued 26 February 2002 Resolved
Provide repair proposal for the following cracked frames. Frame 10 starboard, Frame 12 port and starboard, Frame 18 starboard, Frame 19 port, Frame 20 Starboard, Frame 21 port, Frame port and starboard, Frame 23 starboard. LEGACY COMPONENT DESC: Transverse Frame
Condition: Damaged By Earlier Event
Action required: 705 - Other - as specified
Due 28 March 2002
Resolved 1 March 2002
Engineering
Issued 18 April 2001 Resolved
PROVIDE PROPER FUEL FILTER FOR GENERATOR AS REQUIRED BY 46 CFR 182.455(B)(6)
Condition: Unknown
Due 18 May 2001
Resolved 2 May 2001
Accommodation/Occupational Safety
Issued 18 April 2001 Resolved
PROVIDE RAIL COURSES FOR BOW PULPIT AS REQUIRED BY 46 CFR 177.900
Condition: Unknown
Due 18 May 2001
Resolved 2 May 2001
Electrical
Issued 18 April 2001 Resolved
PROVIDE EMERGENCY LIGHTING AS REQUIRED BY 46 CFR 183.432
Condition: Unknown
Due 18 May 2001
Resolved 2 May 2001
Accommodation/Occupational Safety
Issued 23 April 1998 Resolved
PROPERLY LABEL EMERGENCY FUEL SHUT OFF VALVES.
Condition: Unknown
Due 14 July 1998
Resolved 14 July 1998
Electrical
Issued 23 April 1998 Resolved
PROVIDE AND INSTALL COVERS OVER THE LIGHT FIXTURE IN THE FORWARD CABIN.
Condition: Unknown
Due 14 July 1998
Resolved 14 July 1998
Lifesaving
Issued 23 April 1998 Resolved
PROVIDE VALID RED CROSS /CPR CARDS FOR THE DECKHAND, NVIC 1-91.
Condition: Unknown
Due 14 July 1998
Resolved 14 July 1998
Navigation
Issued 23 April 1998 Resolved
PROVIDE AND POST AN EMERGENCY BROADCAST PLACARD.
Condition: Unknown
Due 14 July 1998
Resolved 14 July 1998
Lifesaving
Issued 23 April 1998 Resolved
PROVIDE AN 18 FOOT LANYARD FOR THE LIFE FLOAT.
Condition: Unknown
Due 14 July 1998
Resolved 14 July 1998
Accommodation/Occupational Safety
Issued 23 April 1998 Resolved
PROVIDE AND POST A LABEL MARKING THE UPPER DECK FOR CREW ONLY.
Condition: Unknown
Due 14 July 1998
Resolved 14 July 1998
Accommodation/Occupational Safety
Issued 23 April 1998 Resolved
PROPERLY MARK EMERGENCY ESCAPE HATCH.
Condition: Unknown
Due 14 July 1998
Resolved 14 July 1998
Engineering
Issued 23 April 1998 Resolved
PROVE PROPER OPERATION OF THE STARBOARD ENGINE TACHOMETER.
Condition: Unknown
Due 14 July 1998
Resolved 14 July 1998
Navigation
Issued 25 March 1997 Resolved
THE VESSEL'S COMPASS LIGHT WAS INOPERATIVE. RENEW OR REPAIR COMPASS LIGHT IAW 46 CFR 184.402(c).
Condition: Unknown
Due 25 March 1997
Resolved 25 March 1997
Navigation
Issued 25 March 1997 Resolved
THE VESSEL DID NOT HAVE A MASTHEAD LIGHT IAW 72 COLREGS (M16672.2) RULE 23.PROPERLY INSTALL MASTHEAD LIGHT AND PROVE PROPER OPERATION.
Condition: Unknown
Due 25 March 1997
Resolved 25 March 1997
Lifesaving
Issued 25 March 1997 Resolved
THE LIFE RING BUOY WATERLIGHT LANYARD DID NOT HAVE A CORROSION RESISTANT CLIP INSTALLED IAW 46 CFR 180.70(d). PROVIDE AND PROPERLY INSTALL CLIP.
Condition: Unknown
Due 25 March 1997
Resolved 25 March 1997
Construction/Loadline
Issued 25 March 1997 Resolved
THE FORWARD MAINDECK HATCH WAS NOT WATERTIGHT. MAKE HATCH WATERTIGHT IAW 46 CFR 179.360.
Condition: Unknown
Due 25 March 1997
Resolved 25 March 1997
Engineering
Issued 25 March 1997 Resolved
THE VESSEL'S FUEL SYSTEM HAD TWO PETCOCK VALVES INSTALLED ON THE FUEL FILTERS. REMOVE PETCOCKS IAW 46 CFR 182.455(a)(3).
Condition: Unknown
Due 25 March 1997
Resolved 25 March 1997
Engineering
Issued 25 March 1997 Resolved
DURING THE SEA TRIAL TWO EXHAUST LEAKS WERE NOTED ONE ON THE STBD MAIN ENGINE INBOARD EXHAUST PIPE AND ONE ON THE SERVICE GENERATOR MUFFLER LOCATED IN THE STEERING SPACE. PROPPERLY REPAIR ALL EXHAUST LEAKS IAW 46 CFR 182.430(b).
Condition: Unknown
Due 25 March 1997
Resolved 25 March 1997
Construction/Loadline
Issued 25 March 1997 Resolved
[withheld — contains personal information; the deficiency system, dates, and resolution status are shown above]
Condition: Unknown
Due 25 March 1997
Resolved 17 April 1997
Construction/Loadline
Issued 25 March 1997 Resolved
THE AFTER SECTIONS OF BOTH THE PORT AND STBD CHINE BOARDS WERE RENEWED AS ORIGINAL. NEW FASTENERS WERE USED.
Condition: Unknown
Due 25 March 1997
Resolved 17 April 1997
Construction/Loadline
Issued 25 March 1997 Resolved
THE FOLLOWING HULL PLANKES WERE FOUND LOOSE AND WERE REFASTENED: FIRST PLANK BELOW THE CHINE ON BOTH PORT AND STBD SIDES AND ALL THE STBD HUL PLANKS ABOVE THE WATER LINE AT THE STEM. ALL PLANKS WERE REFASTENED WITH 316 STAINLESS STEEL BOAT NAILS,
Condition: Unknown
Due 25 March 1997
Resolved 17 April 1997
Construction/Loadline
Issued 25 March 1997 Resolved
3 SHORT PLANKS WERE NOTED AND RENEWED ON THE PORT QUARTER IAW COAST GUARD NVIC 7-95.
Condition: Unknown
Due 25 March 1997
Resolved 17 April 1997
Construction/Loadline
Issued 25 March 1997 Resolved
ANGLE HAIR FUNGUS WAS FOUND IN THE ENGINE ROOM OVERHEAD AND FRAMING. OWNERREMOVED 90% OF THE ANGEL HAIR AND TREATED THE WOOD WITH WHITE VINEGAR.
Condition: Unknown
Due 25 March 1997
Resolved 17 April 1997
Navigation
Issued 25 March 1997 Resolved
THE VESSEL'S PORT AND STBD RUDDER SHAFT WERE EXCESSIVELY WORN CAUSING THE RUDDER TO ROCK WITHIN THE SHAFT TUBES APPROXIMATELY 1.5". RUDDER SHAFTS WERE BUILT UP AND MACHINED, THE RUDDER TUBES WERE RENEWED.
Condition: Unknown
Due 25 March 1997
Resolved 17 April 1997
Lifesaving
Issued 25 March 1997 Resolved
THE VESSEL DID NOT HAVE A LIFEJACKET DONNING PLCARD IAW 46 CFR 185.516. PROVIDE AND POST PLACARD.
Condition: Unknown
Due 25 March 1997
Resolved 25 March 1997
Lifesaving
Issued 25 March 1997 Resolved
THE VESSEL'S LIFEFLOAT RETRO-REFLECTIVE TAPE WAS WORN/UNSERVICEABLE AND THEWATERLIGHT WAS IMPROPERLY MOUNTED TO THE LIFEFLOAT. REPAIR HOLES IN LIFEFLOAT WERE WATERLIGHT BRACKET WAS MAOUNTED AND RENEW RETRO TAPE IAW 46 CFR 160.027.
Condition: Unknown
Due 25 March 1997
Resolved 25 March 1997
Lifesaving
Issued 25 March 1997 Resolved
3 ADULT LIFEJACKETS WERE WORN/TORN AND UNSERVICEABLE, JACKETS WERE CONDEMED. RENEW 3 ADULT TYPE I LIFEJACKETS IAW 46 CFR 180.71(a).
Condition: Unknown
Due 25 March 1997
Resolved 25 March 1997
Lifesaving
Issued 25 March 1997 Resolved
1 CHILD LIFEJACKET WAS FOUND UNSERVICABLE AND WAS CONDEMED. PROVIDE 1 CHILD TYPE 1 LIFEJACKET IAW 46 CFR 180.71(b).
Condition: Unknown
Due 25 March 1997
Resolved 25 March 1997
Electrical
Issued 29 March 1996 Resolved
PROVIDE MANUFACTURE DATA PLATE FOR GENERATOR AND GENERATOR AMBIENT TEMPERATOR RATING.
Condition: Unknown
Due 29 April 1996
Resolved 7 May 1996
Accommodation/Occupational Safety
Issued 29 March 1996 Resolved
PROVIDE INDICATOR FOR MSD TANK TO SHOW 3/4 FULL BY VOLUME.
Condition: Unknown
Due 29 April 1996
Resolved 7 May 1996
Lifesaving
Issued 29 March 1996 Resolved
PROVIDE AND POST LIFE JACKET DONNING PLACARD.
Condition: Unknown
Due 29 April 1996
Resolved 7 May 1996
Engineering
Issued 29 March 1996 Resolved
PROVE PROPER OPERATION OF PORT TACH.
Condition: Unknown
Due 29 April 1996
Resolved 7 May 1996
Engineering
Issued 29 March 1996 Resolved
MAKE REPAIRS TO PORT/STBD RUDDER PACKING.
Condition: Unknown
Due 29 April 1996
Resolved 7 May 1996
Lifesaving
Issued 29 March 1996 Resolved
PROVIDE TAG FOR LIFE FLOAT WEAK LINK.
Condition: Unknown
Due 29 April 1996
Resolved 7 May 1996
Engineering
Issued 29 March 1996 Resolved
MAKE REPAIRS TO THRU HULL FOR GENERATOR EXHAUST PIPING AND CONDUCT TEST.
Condition: Unknown
Due 29 April 1996
Resolved 7 May 1996
Navigation
Issued 29 March 1996 Resolved
PROVIDE COMPASS DEVIATION TABLE.
Condition: Unknown
Due 29 April 1996
Resolved 7 May 1996
Engineering
Issued 20 September 1995 Resolved
INSTALL PIPE PLUGS ON PORT AND STBD F/O TANK DRAIN VALVES.
Condition: Unknown
Due 20 September 1995
Resolved 20 September 1995
Construction/Loadline
Issued 20 September 1995 Resolved
REPAIR HULL LEAK IN FOREPEAK POST SIDE AT STEM APPROX 6" ABOVE KEEL.
Condition: Unknown
Due 20 September 1995
Resolved 20 September 1995
Navigation
Issued 20 September 1995 Resolved
MAKE REPAIRS TO PORT RUDDER SHAFT.
Condition: Unknown
Due 20 September 1995
Resolved 20 September 1995
Construction/Loadline
Issued 20 September 1995 Resolved
INSTALL PIPE PLUG ON THRU BULKHEAD VALVE MOUNTED ON COLLISION BULKHEAD.
Condition: Unknown
Due 20 September 1995
Resolved 20 September 1995
Navigation
Issued 20 September 1995 Resolved
PROVIDE PROPER SIZE BELL I.A.W. 72 COLREGS ANNEX 3. (7.9 OR 200MM)
Condition: Unknown
Due 20 September 1995
Resolved 20 September 1995
Engineering
Issued 20 September 1995 Resolved
INSTALL MACHINERY GUARDS ON STBD ENGINE. (FRONT)
Condition: Unknown
Due 20 September 1995
Resolved 20 September 1995
Electrical
Issued 20 September 1995 Resolved
PROVIDE BATTERY BOX COVERS FOR BATTERIES OR TERMINAL END COVERS
Condition: Unknown
Due 20 September 1995
Resolved 20 September 1995
Construction/Loadline
Issued 20 September 1995 Resolved
MAKE COLLISION BULKHEAD WATER TIGHT AND CONDUCT HYDRO TEST IN THE PRESENT OF MARINE INSPECTOR.
Condition: Unknown
Due 20 September 1995
Resolved 20 September 1995
Lifesaving
Issued 20 September 1995 Resolved
REPAINT AND RESTENCIL NAME OF VESSEL ON LIFE RING BOUY.
Condition: Unknown
Due 20 September 1995
Resolved 20 September 1995
Electrical
Issued 3 April 1995 Resolved
INSTALL GENERATOR AMP METER AS REQUIRED BY 46CFR183.10-5(G).
Condition: Unknown
Due 3 May 1995
Resolved 23 June 1995
Lifesaving
Issued 3 April 1995 Resolved
INSTALL RETROREFLECTIVE TAPE ON BOTH LIFE FLOATS.
Condition: Unknown
Due 3 May 1995
Resolved 23 June 1995
Accommodation/Occupational Safety
Issued 3 April 1995 Resolved
COMPLETE INSTALLATION AND PROVE PROPER OPERATION OF MARINE SANITATION DEVICE.
Condition: Unknown
Due 3 May 1995
Resolved 23 June 1995
Engineering
Issued 3 April 1995 Resolved
REPLACE BOTH PROPULSION ENGINE COOLING WATER SUPPLY HOSES.
Condition: Unknown
Due 3 May 1995
Resolved 23 June 1995
Electrical
Issued 3 April 1995 Resolved
INSTALL METAL WIRE TIE/CLAMPS ON OVERHEAD WIRE RUNS IN ENGINE COMPARTMENT AT INTERVALS OF 18".
Condition: Unknown
Due 3 May 1995
Resolved 23 June 1995
Electrical
Issued 3 April 1995 Resolved
PROPERLY MARK 12VDC BREAKER PANEL.
Condition: Unknown
Due 3 May 1995
Resolved 23 June 1995
Lifesaving
Issued 3 April 1995 Resolved
STENCIL FWD ACCOMMODATIONS EMERGENCY ESCAPE HATCH.
Condition: Unknown
Due 3 May 1995
Resolved 23 June 1995
Engineering
Issued 3 April 1995 Resolved
RE-STENCIL REMOTE FUEL SHUTOFF VALVES.
Condition: Unknown
Due 3 May 1995
Resolved 23 June 1995
Engineering
Issued 3 April 1995 Resolved
INSTALL PULLEY GUARDS ON BOTH ENGINES.
Condition: Unknown
Due 3 May 1995
Resolved 23 June 1995
Construction/Loadline
Issued 3 March 1994 Resolved
CLOSE VENTILATION OPENINGS IN INNER PERIPHERY OF COCKPIT.
Condition: Unknown
Due 7 April 1994
Resolved 8 April 1994
Engineering
Issued 3 March 1994 Resolved
REPLACE UNAPPROVED FUEL HOSE TO GENERATOR
Condition: Unknown
Due 7 April 1994
Resolved 8 April 1994
Lifesaving
Issued 14 April 1993 Resolved
REPLACE BATTERY IN EPIRB.
Condition: Unknown
Due 14 April 1993
Resolved 14 April 1993
Construction/Loadline
Issued 14 April 1993 Resolved
INSTALL CHECK VALVE IN BILGE SUCTION LINE IN ENGINE ROOM IAW 46 CFR 182.25-5(c).
Condition: Unknown
Due 21 April 1993
Resolved 27 April 1993
Construction/Loadline
Issued 14 April 1993 Resolved
REPAIR ELECTRIC BILGE PUMP IN AFT STEERING COMPARTMENT IAW 182.25-10.
Condition: Unknown
Due 21 April 1993
Resolved 27 April 1993
Engineering
Issued 14 April 1993 Resolved
PROVIDE EMERGENCY FUEL SHUT OFF VALVES IAW 46 CFR 182.20-40(b)(3).
Condition: Unknown
Due 21 April 1993
Resolved 27 April 1993
Navigation
Issued 19 June 1991 Resolved
REMOVE ALL TINTED WINDOWS IN PILOT HOUSE. REPLACE WITH CLEAR WINDOWS, OR PROVE NO MORE THAN 20 PERCENT OF THE LIGHT IS FILTERED OUT. TEST IS TO BE WITNESSED BY COAST GUARD MARINE INSPECTOR_x001C_ _x001C_
Condition: Unknown
Due 19 June 1991
Resolved 19 June 1991
Electrical
Issued 24 April 1991 Resolved
INSTALL FREQUENCY METER IN A/C GEN. PANEL AND PROVE PROPER OPERATION OF AMPMETER IN A/C GEN. PANEL._x001C_ _x001C_ _x001C_
Condition: Unknown
Due 24 April 1991
Resolved 24 April 1991
Documentation
Issued 20 April 1989 Resolved
PROVIDE FCC SAFETY RADIOTELEPHONE CERTIFICATE.
Condition: Unknown
Due 20 April 1989
Resolved 20 April 1989
Documentation
Issued 20 April 1989 Resolved
PROVIDE FCC OPERATORS LICENSE.
Condition: Unknown
Due 20 April 1989
Resolved 20 April 1989
Lifesaving
Issued 20 April 1989 Resolved
CONNECT BOTH LIFEFLOATS TOGETHER OR PROVIDE SUITABLE 100FT PAINTER AND WEAKLINK FOR 6MAN LIFEFLOAT.
Condition: Unknown
Due 20 April 1989
Resolved 20 April 1989
Lifesaving
Issued 20 April 1989 Resolved
PAINT VESSEL NAME ON BOTH LIFEFLOATS.
Condition: Unknown
Due 20 April 1989
Resolved 20 April 1989
Lifesaving
Issued 20 April 1989 Resolved
PAINT VESSEL NAME ON LIFEJACKETS.
Condition: Unknown
Due 20 April 1989
Resolved 20 April 1989
Construction/Loadline
Issued 20 April 1989 Resolved
TREAT VESSEL'S STEERING COMPARTMENT WITH A WOOD PRESERVATIVE(REMOVE ROT FIRST.
Condition: Unknown
Due 20 April 1989
Resolved 20 April 1989
Documentation
Issued 20 April 1989 Resolved
PROVIDE EVIDENCE OF VESSEL'S STABILITY LETTER OR CONDUCT STABILITY TEST TO SATISFACTION OF [name withheld].
Condition: Unknown
Due 20 April 1989
Resolved 20 April 1989
Electrical
Issued 20 April 1989 Resolved
SUBMIT REVISED ELECTRICAL DRAWING FOR ALL ELECTRICAL SYSTEMS ON VESSEL TO INCLUDE CONDUCTOR TYPE/SIZE, ALL OVER CURRENT PROTECTION(BREAKERS, FUSES) GENERATOR INSTALLATION, BATTERY INSTALLATION, ETC.
Condition: Unknown
Due 20 April 1989
Resolved 20 April 1989
Navigation
Issued 20 April 1989 Resolved
REPAIR OR REMOVE FURUNO RADAR.
Condition: Unknown
Due 20 April 1989
Resolved 20 April 1989
Electrical
Issued 20 April 1989 Resolved
REMOVE ALL DEAD END AND UNUSED WIRING THROUGHOUT VESSEL.
Condition: Unknown
Due 20 April 1989
Resolved 20 April 1989
Construction/Loadline
Issued 20 April 1989 Resolved
DOUBLE CLAMP ALL SEA WATER INTAKE AND CIRCULATION HOSED THROUGHOUT THE VESSEL.
Condition: Unknown
Due 20 April 1989
Resolved 20 April 1989
Documentation
Issued 20 April 1989 Resolved
PROVIDE FCC STATION LICENSE.
Condition: Unknown
Due 20 April 1989
Resolved 20 April 1989
Documentation
Issued 20 April 1989 Resolved
PROVIDE EVIDENCE OF VESSEL NAME CHANGE AND OWNERSHIP CHANGE TO CERTIFICATE OF DOCUMENTATION.
Condition: Unknown
Due 20 April 1989
Resolved 20 April 1989
Lifesaving
Issued 20 April 1989 Resolved
PAINT VESSEL NAME ON BOTH LIFE RINGS.
Condition: Unknown
Due 20 April 1989
Resolved 20 April 1989
Lifesaving
Issued 20 April 1989 Resolved
PAINT VESSEL NAME ON LIFEFLOAT PADDLE.
Condition: Unknown
Due 20 April 1989
Resolved 20 April 1989
Engineering
Issued 20 April 1989 Resolved
REMOVE AND PROPERLY DISPOSE OF EXCESS OIL IN VESSELS BILGES.
Condition: Unknown
Due 20 April 1989
Resolved 20 April 1989
Unknown
Issued 7 April 1988 Resolved
RECAULK TWO BUTT JOINTS ON THE GARBOARD STRAKE - ONE PORT, ONE STBD.
Condition: Unknown
Due 7 April 1988
Resolved 7 April 1988
Unknown
Issued 7 April 1988 Resolved
PULL ONE FASTNER FORWARD AT THE BOW IN WAY OF THE WIND AND WATER LINE AND ONE IN THE TRANSOM IN WAY OF THE NORMAL BILGE WATER LEVEL.
Condition: Unknown
Due 7 April 1988
Resolved 7 April 1988
Unknown
Issued 7 April 1988 Resolved
MAKE REPAIRS TO REMOVE DECAYED WOOD AND INHIBIT FURTHER DECAY TO THE KEEL- PORT SIDE FORWARD.
Condition: Unknown
Due 7 April 1988
Resolved 7 April 1988
Unknown
Issued 7 April 1988 Resolved
REMOVE COPPER PATCH AND MAKE REPAIRS AS NECESSARY TO A 4" X 4" AREA LOCATED2' FORWARD OF THE TRANSDUCER PORT SIDE.
Condition: Unknown
Due 7 April 1988
Resolved 7 April 1988
Unknown
Issued 7 April 1988 Resolved
REPLACE 1/2" AIR CONDITIONING GATE VALVE AND 1" WASHBOARD PUMP GATE VALVE.
Condition: Unknown
Due 7 April 1988
Resolved 7 April 1988
Unknown
Issued 7 April 1988 Resolved
MAKE PERMANENT REPAIRS TO THE TRANSVERSE FRAME LOCATED IMMEDIATELY ABOVE THE AFTER STRUTS. RESECURE AFTER STRUTS AS NECESSARY FOLLOWING REPAIR.
Condition: Unknown
Due 7 April 1988
Resolved 7 April 1988
Unknown
Issued 7 April 1988 Resolved
REPLACE STRAINERS TO MAIN ENGINE COOLING PORT AND STARBOARD.
Condition: Unknown
Due 7 April 1988
Resolved 7 April 1988
Documentation
Issued 8 April 1987 Resolved
PROVIDE AND POST FCC RADIO SAFETY CERTIFICATE.
Condition: Unknown
Due 8 April 1987
Resolved 8 April 1987
Accommodation/Occupational Safety
Issued 3 May 1984 Resolved
INSTALL EVENLY SPACED COURSES NOT GRATER THAN 12" APART ON THE BOW DK HAND RAIL & THE UPPER WH DK ACCESS. TO PASS. & CREW.
Condition: Unknown
Due 3 May 1984
Resolved 3 May 1984
Lifesaving
Issued 2 April 1984 Resolved
REPLACE GRAB LINES ON LIFE RING BUOYS
Condition: Unknown
Due 2 April 1984
Resolved 2 April 1984
Lifesaving
Issued 2 April 1984 Resolved
NEED TO INSTALL WEAK LINKS (FLOAT FREE LINKS) ON 2 LIFE FLOATS.
Condition: Unknown
Due 2 April 1984
Resolved 2 April 1984
Lifesaving
Issued 2 April 1984 Resolved
NEED TO INSTALL A MEANS TO GET ON DECK WHERE LIFE FLOATS ARE STOWED.
Condition: Unknown
Due 2 April 1984
Resolved 2 April 1984

Casualty record · 1

17 June 2017Routine · role: Involved in a Marine Casualty · serious marine incident, as classified · 1 dead · activity 6183123
Each line is an incident investigation the Coast Guard recorded with this hull among the vessels involved, with the date and the classification the Coast Guard gave it, and the bridge, lock or dam the investigation names where it names one. Involvement is not fault. The investigation narrative is not published. Source: IIR, through 2026.

Recorded names · 1

INTRUDER (2017). Names as the Coast Guard recorded them in incident records, with the years they appear; some are renames and some are spelling variants.

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.