Passenger (Inspected) · Passenger Ship class · Built 1970s · USCG Southeast District (CGD-SE) · Other hulls named FLYING FISH
FLYING FISH is a 1974 passenger vessel (inspected). The Coast Guard has recorded 72 inspections since 1985, most recently in March 2026, along with 163 deficiencies — 1 with no resolution recorded — and 2 casualty investigations between 2010 and 2017.
Records from 1985 to 2026. Most recent: inspection, 13 March 2026.
- Built
- 1974
- Last inspected
- 13 March 2026
- Documentation
- Valid · documentation file of 10 September 2026
- Deficiencies
- 163 recorded · 1 without a recorded resolution
- Controls
- None recorded without a removal date
- Casualties
- 2 investigations · 2010–2017
Identity
555455
WDL8110
47909
Flag
UNITED STATES
367447080
Maury page id
psix-47909
Inspections, by type
…with no type recorded6
Years with a record
39 calendar years (1985–2026)
The 72 inspections in the strip above, split by the kind of activity the US
Coast Guard recorded. Years with a record are calendar years in which a record exists, not
years in service. What Maury does not do.
Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Passenger Ship class in Maury's sources begin in 1977.
Documentation record
Registered dimensions (L × B × D)73.8 ft × 22.0 ft × 7.1 ft
Registered tonnagegross 66 / net 45
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
BuilderGULF CRAFT INC · PATTERSON, LA, UNITED STATES · built 1974
Hull materialAluminum
PropulsionDiesel Reduction
Hull shapeNot recorded
Hull configurationNot recorded
Hailing portSARASOTA, FL
Trade endorsementsCoastwise, unrestricted, Fishery, Recreational
DocumentationValid · issued 21 August 2025 · expires 31 August 2026
Service, as the file records itPassenger (Inspected)
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it66 - Regulatory (Subpart C or D), Gross Ton
45 - Regulatory (Subpart C or D), Net Ton
45 - Regulatory (Subpart C or D), Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 September 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.
Radio station licence
WDL8110MMSI 367447080 · active · compulsorily equipped · granted 15 October 2020, expires 15 October 2030
WDF4031MMSI 367447080 · expired · compulsorily equipped · granted 13 April 2010, cancelled 13 June 2020
WCZ7517MMSI not assigned · expired · compulsorily equipped · granted 12 April 2000, cancelled 12 June 2010
WBP4734MMSI not assigned · expired · compulsorily equipped · granted 18 December 1997, cancelled 22 March 2008 · licensed under a name not among this hull’s recorded names (not shown)
FCC Universal Licensing System ship-station file of 6 September 2026, matched to this hull on its
US Official Number. Status and dates are the file’s own. The licensee is not read from the file and is not shown.
A lapsed licence’s MMSI is still the number the vessel transmitted under while it was valid.
Inspection history · 72
13 March 2026
Administrative Inspection · Deficiency Check · COI Inspection
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 8317487
8 April 2025
Drydock Exam · Administrative Inspection · Internal Structural Exam · Vessel Attendance · Examination of Repairs
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 8086800
20 November 2024
Annual Inspection
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 8026265
13 November 2023
Annual Inspection · Deficiency Check
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 7810006
3 April 2023
Deficiency Check · Annual Inspection
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 7593999
4 October 2022
In-Service Inspection · Administrative Inspection · Hull Examination · Internal Structural Exam · Examination of Repairs
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 7571165
16 November 2021
Annual Inspection · Deficiency Check
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 7352375
27 August 2020
Drydock Exam · Internal Structural Exam
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 7024104
26 August 2020
COI Inspection · Deficiency Check · DAPI Audit
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 7024096
31 October 2019
Annual Inspection · DAPI Audit · Examination of Repairs · Administrative Inspection
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 6840614
3 December 2018
DAPI Audit · Administrative Inspection · Deficiency Check · Annual Inspection · Examination of Repairs
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 6586713
12 September 2018
Hull Examination · Internal Structural Exam · Administrative Inspection · Examination of Repairs
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 6533338
14 November 2017
Annual Inspection
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 6306780
26 August 2017
Type not recorded
No type recorded · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 6255993
9 September 2016
Annual Inspection · Deficiency Check · Drydock Exam · Internal Structural Exam
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 5979745
4 September 2015
DAPI Audit · Deficiency Check · COI Inspection
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 5232010
27 August 2014
Drydock Exam · Internal Structural Exam
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 4967013
12 August 2014
Annual Inspection · Deficiency Check · DAPI Audit
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 4952898
30 July 2012
Administrative Inspection · Annual Inspection · DAPI Audit · Deficiency Check
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 4396135
8 August 2011
Annual Inspection · Administrative Inspection
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 4119697
22 October 2010
Internal Structural Exam · Administrative Inspection · Hull Examination
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 3874290
29 January 2010
Type not recorded
No type recorded · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 3680474
17 September 2008
Hull Examination
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 3326612
27 August 2008
Deficiency Check · Annual Inspection
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 3310063
5 October 2006
Hull Examination
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 2778130
22 August 2006
Deficiency Check · Annual Inspection
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 2750753
23 May 2005
Deficiency Check · COI Inspection
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 2362615
20 September 2004
Deficiency Check · Examination of Repairs · Hull Examination
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 2183446
24 August 2004
Annual Inspection
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 2168747
16 September 2003
Deficiency Check
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1895810
26 August 2003
Annual Inspection
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1873579
5 December 2002
Hull Examination
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1705442
3 September 2002
Annual Inspection
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1664889
23 August 2001
Deficiency Check
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1072453
4 June 2001
Re-Inspection
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1382280
5 February 2001
Deficiency Check
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1056581
21 August 2000
Deficiency Check
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 821163
22 May 2000
COI Inspection
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1421877
31 May 1999
Deficiency Check
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1110779
17 May 1999
Re-Inspection
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1384143
17 December 1998
Type not recorded
No type recorded · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 806803
1 December 1998
Hull Examination
Physical examination · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 1106562
29 September 1998
Type not recorded
No type recorded · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 228709
24 June 1998
Administrative
Administrative · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 1127687
17 April 1998
COI Inspection
Physical examination · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 789621
9 April 1997
Re-Inspection · MARPOL Annex V Examination
Physical examination · GROUP/MSO LONG ISLAND SOUND · USCG Northeast District (CGD-NE) · Activity 1103186
20 March 1997
Type not recorded
No type recorded · GROUP/MSO LONG ISLAND SOUND · USCG Northeast District (CGD-NE) · Activity 1103213
18 November 1996
Hull Examination
Physical examination · GROUP/MSO LONG ISLAND SOUND · USCG Northeast District (CGD-NE) · Activity 1398793
9 April 1996
MARPOL Annex V Examination · COI Inspection
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1079731
10 April 1995
MARPOL Annex V Examination · COI Inspection
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1155226
8 February 1995
Deficiency Check
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 843036
25 January 1995
Hull Examination
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1142265
13 April 1994
COI Inspection · MARPOL Annex V Examination
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1168780
15 April 1993
COI Inspection
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 832081
30 March 1993
Hull Examination
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 837262
26 October 1992
Drydock Extension
Administrative · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 938555
10 April 1992
COI Inspection
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 953445
4 April 1991
Hull Examination
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 902348
26 March 1991
Administrative
Administrative · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1219422
26 March 1991
COI Inspection
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1219591
27 March 1990
COI Inspection
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 924123
1 November 1989
Deficiency Check · Hull Examination
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 907015
19 June 1989
Deficiency Check
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1038694
27 March 1989
COI Inspection
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1343960
10 October 1988
Deficiency Check
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1035493
31 March 1988
COI Inspection
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1034406
24 March 1988
Hull Examination · Plan Review "T" Boat
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1040419
26 March 1987
Hull Examination
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1325262
18 March 1987
COI Inspection
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1016309
28 March 1986
Credit Drydock
Administrative · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 997896
21 March 1986
COI Inspection
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1304756
22 March 1985
Type not recorded
No type recorded · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1289671
Deficiency record · 163
07 - Fire Safety › N/A - No Subsystem › Fixed fire extinguishing installation
Issued 13 March 2026
Resolved
S and L. If 1 1/2 inch fire hose is used after January 1, 1980 then each length of hose must be lined commercial fire hose that conforms to UL19 or ZZ-H-451E. A hose that bears the Label of Underwriters' Laboratories, Inc. as lined fire hose is accepted. MI observed no marking of conformity that aligned with requirements. Replace hose on-board with conforming hose standards.
46CFR181.15-10(d)(1)
16c
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 13 March 2026
Resolved
A vessel of more than 65 feet in length must carry a minimum of three life buoys of not less than 24 in. in diameter. MI observed one ring life buoy of 20 in. in diameter of the three required and available onboard. Replace 20 in. life buoy with 24 in. life buoy and provide photographic evidence of all three required buoys in single capture.
46CFR180.70(a)(3)
16c
07 - Fire Safety › N/A - No Subsystem › Fixed fire extinguishing installation
Issued 13 March 2026
Resolved
On a vessel of more thn 65 feet in length the minimum capacity of the fire pump must be 50 gallons per minute at a pressure of not more than 60 psi at the pump outlet. MI observed psi at 25-27 psi at the pump outlet for the 4-5 minute duration of the fire pump in operation. Ensure pressure meets requirement.
46CFR181.300(b)
16c
04 - Emergency Systems › N/A - No Subsystem › Emergency, lighting, batteries and switches
Issued 13 March 2026
Resolved
Electrical equipment on a vessel must be installed and maintained to: Minimize accidental personnel contact with energized parts. Make repair to electrical wiring in #3 void forward and install appropriate bulb/cover in engine room light fixture.
46 CFR 183.200
16c
04 - Emergency Systems › N/A - No Subsystem › Public address system
Issued 13 March 2026
Resolved
On a vessel of more than 65 feet in length, the PA system must be a fixed installation and audible during normal operating conditions throughout the accommodation spaces and all other spaces normally manned by crew members [name withheld] system to be audible thru out all accommodation space or plan for effective communication, ie. walkie talkies.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 6 October 2025
No resolution recorded
No major repairs or alterations affecting the safety of the vessel with regard to hull, machinery, or equipment shall be made without the knowledge and apprioval of [name withheld] noticed two battery chargers were installed without
permanent wiring. Provide wiring diagram for the vessel.
46CFR(old) 176.20-1(a)
01 - Certificates & Documentation › 011 - Ships Certificates › Certificate of Inspection (COI)
Issued 21 May 2025
Resolved
A vessel that is exposed to salt water more than three months in any 12 month period since the last examination must undergo a drydock examination and an internal structural at least once every two years. Vessel dry dock inspection drop dead date is 31MAR2025. Vessel must undergo a satisfactory dry dock and internal structural exam prior to the carriage of passengers.
46 CFR 176.600(c)(1)
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 13 November 2023
Resolved
An adult life jacket must be provided for each person carried on board a vessel.
Vessel is missing one adult life jacket.
Maximum passenger count is reduced to 71.
46CFR180.71(a)
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 13 November 2023
Resolved
Each portable fire extinguisher on a vessel must be of an approved type. The minimum number of portable fire extinguishers required on a vessel must be acceptable to the OCMI but must not be fewer than the minimum number required by Table 181.500(b).
MIs found the 80B:C portable fire extinguisher located in the wheelhouse to be low on charge.
46CFR181.500(a)
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 13 November 2023
Resolved
At least one ring life buoy must be fitted with a lifeline.
MIs observed the lifeline on the aft ring life buoy to be deteriorated.
46CFR180.70(c)
03 - Water/Weathertight Conditions › N/A - No Subsystem › Railing, gangway, walkway and means for safe passage
Issued 13 November 2023
Resolved
An exposed hazard, such as gears or rotating machinery, must be properly protected by a cover, guard, or rail.
MIs observed the guards on both main engines to be removed exposing the rotating machinery.
46CFR177.960
11 - Life Saving Appliances › N/A - No Subsystem › Operational readiness of lifesaving appliances
Issued 3 April 2023
Resolved
Each life float must be fitted with a lifeline, pendants, two paddles, a painter, and a light.
The three lifefloats were found with corroded and broken paddles.
46 CFR 180.175(d)
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 3 April 2023
Resolved
In damp or wet locations, the cable entrance shall be watertight.
The weather exposed light housing located on the aft main deck was found with an un-sealed cable entrance.
46 CFR 183.10-20(f)(3)
01 - Certificates & Documentation › 011 - Ships Certificates › Certificate of Inspection (COI)
Issued 4 October 2022
Resolved
A vessel that is exposed to salt water more than three months in any 12 month period since the last examination must undergo a drydock examination and an internal structural at least once every two years. MI discovered the valid DD period ended on 30Sep2022.
46 CFR 176.600 (c)(1)
10 - Safety of Navigation › N/A - No Subsystem › Lights, shapes, sound-signals
Issued 16 November 2021
Resolved
10109 - All vessels must have navigation lights, a vessel of more than 19.8 meters (65 feet) in length must also have navigation lights that meet UL 1104. Navigation lights did not meet UL 1104. - 46 CFR 183.420 - 16C
07 - Fire Safety › N/A - No Subsystem › Fire pumps and its pipes
Issued 26 August 2020
Resolved
A power-driven fire pump shall be installed on each mechanically propelled "L" vessel.
Repair or replace inoperable fire pump.
46CFR181.10-1(a)"Old T"
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 26 August 2020
Resolved
All vessels shall be provided with a satisfactory arrangement for draining any watertight compartment other than small buoyancy compartments, under all practical conditions.
Ensure proper drainage of lazarette space.
46CFR182.25-1(a)"Old T"
11 - Life Saving Appliances › N/A - No Subsystem › Rigid liferafts
Issued 26 August 2020
Resolved
A life float—Approved under approval series 160.027 and be in good serviceable condition.
Life floats were missing manufacture placards and multiple fasteners for the lifeline and pennants were broken.
Replace/renew life floats to meet the requirements of 46CFR160.027
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 26 August 2020
Resolved
Each child and adult size life jacket must be stowed in a location that is appropriately marked and separated, so the child size life jackets are not mistaken for adult life jackets.
Life Jacket stowage locations were not marked.
46CFR180.200(a)(5)
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 26 August 2020
Resolved
An adult life jacket must be provided for each person carried on board a vessel.
5 adult life jackets were unserviceable and 2 adult life jackets and 2 child life jackets had unserviceable retro-reflective tape.
Replace unserviceable jackets and replace retro-reflective tape as needed.
46CFR180.71(a)
10 - Safety of Navigation › N/A - No Subsystem › Lights, shapes, sound-signals
Issued 26 August 2020
Resolved
All vessels must have navigation lights that are in compliance with the applicable sections of the International and Inland Navigation Rules.
Repair or replace navigation lights.
46CFR183.420
10 - Safety of Navigation › N/A - No Subsystem › Charts
Issued 26 August 2020
Resolved
As appropriate for the intended voyage, a vessel must carry adequate and up-to-date charts of large enough scale to make safe navigation possible.
Provide up-to-date charts of sufficient scale.
46CFR184.420
04 - Emergency Systems › N/A - No Subsystem › Man Overboard Drill (MOB)
Issued 26 August 2020
Resolved
The master shall conduct sufficient drills and give sufficient instructions to make sure that all crew members are familiar with their duties during emergencies that necessitate abandoning ship or the recovery of persons who have fallen overboard.
Conduct man overboard drill to the satisfaction of the attending marine inspector.
46CFR185.520(a)
09 - Working and Living Conditions › 092 - Working Conditions › Lighting (Working spaces)
Issued 26 August 2020
Resolved
Electrical equipment on a vessel must be installed and maintained to provide services necessary for safety under normal and emergency procedures.
The vessel’s engine room did not have adequate lighting. Repair or replace.
46CFR185.524(a)
04 - Emergency Systems › N/A - No Subsystem › Fire drills
Issued 26 August 2020
Resolved
The master shall conduct sufficient fire drills to make sure that each crew member is familiar with his or her duties in case of a fire.
Conduct fire drill to the satisfaction of the attending marine inspector.
46CFR183.200(a)
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 26 August 2020
Resolved
Electrical equipment on a vessel must be installed and maintained to protect passengers, crew, or other persons and the vessel from electrical hazards, including fire, caused by or originating in electrical equipment, and electrical shock.
Loose and dead end wires were observed throughout the engine room.
46CFR183.200(b)
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 26 August 2020
Resolved
The marine employer shall ensure that all persons directly involved in a serious marine incident are chemically tested for evidence of dangerous drugs and alcohol.
Alcohol test strips used for testing within 2 hours of a serious marine incident are expired. Replace.
46CFR16.240
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 26 August 2020
Resolved
By March 15 of the year following the collection of the drug testing program data, marine employers must submit the data on the MIS Date Collection Form.
Missing 2019 MIS report.
Provide 2019 MIS report to ensure submission of data within the specified time frame.
46CFR16.500(b)
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 26 August 2020
Resolved
Protect passengers, crew, other persons, and the vessel from electrical hazards, including fire, caused by or
originating in electrical equipment, and electrical shock.
Exposed wires were observed on the electrical shore tie.
Repair/Replace shore tie.
46CFR183.200(b)
05 - Radio Communications › N/A - No Subsystem › MF Radio installation
Issued 26 August 2020
Resolved
Vessels operated beyond the 20 nautical mile limitation specified in paragraph (a)(1) of this section, but not more than 100 nautical miles from the nearest land, must be equipped with a MF–DSC frequency transmitter meeting the requirements of § 80.1101(c)(3)
Vessel has an Oceans route not more the 100 miles and is operating without a MF–DSC frequency transmitter.
Vessel route is restricted to coastwise till MF radio is installed and certified.
47CFR80.905(a)(2)
05 - Radio Communications › N/A - No Subsystem › Other (radio communication)
Issued 26 August 2020
Resolved
A vessel must comply with the applicable requirements for any radio installations including the requirements for a station license to be issued by the FCC.
Renew expired FCC Station License.
46CFR184.502
05 - Radio Communications › N/A - No Subsystem › Other (radio communication)
Issued 26 August 2020
Resolved
Every vessel subject to Part II or Title III of the Communications Act must have a detailed inspection of the radio installation by an FCC-licensed technician to receive a Communications Act Safety Radiotelephony Certificate.
Obtain a new Safety Radiotelephony Certificate after installing MF radio.
47CFR80.903
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 31 October 2019
Resolved
All vessels shall be provided with bilge pumps in accordance with Table 182.25-10(a) - old T. Make repairs and prove operation of secondary engine driven bilge pump servicing forward compartments and secondary engine driven bilge pump servicing aft compartments. 46CFR182.25-10 (old T).
07 - Fire Safety › N/A - No Subsystem › Fire pumps and its pipes
Issued 31 October 2019
Resolved
Make repairs to leaking port side fire main riser at deck valve as identified. All piping, valves, and fittings shall be in accordance with good marine practice and suitable for the purpose intended. 46CFR181.15-5(c) (old T).
07 - Fire Safety › N/A - No Subsystem › Fire pumps and its pipes
Issued 3 December 2018
Resolved
A power driven fire pump shall discharge a minimum capacity of 50 gpm at a pressure not less than 60 psi at the pump outlet.
Prove proper fire pump capacity. 46 CFR 181.10-1
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 3 December 2018
Resolved
All electrical equipment shall be drip proof protected
Provide drip proof material above electrical components in forward engine room. 46 CFR 183.10-10
02 - Structural Conditions › N/A - No Subsystem › Ballast, fuel and other tanks
Issued 3 December 2018
Resolved
At each initial and subsequent inspection for certification the marine inspector shall examine and test the following items to the extent necessary to determine that they are in proper operating condition and fit for service intended.
Repair or replace hydraulic sight glass on hydraulic tank in engine room. 46 CFR 176.25-10
02 - Structural Conditions › N/A - No Subsystem › Closing devices/watertight doors
Issued 3 December 2018
Resolved
All escape hatches and other emergency exits shall be marked on both sides using at least one inch letters, "EMERGENCY EXIT, KEEP CLEAR".
Mark engine room escape hatch as required above. 46 CFR 185.30-15
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 3 December 2018
Resolved
Portable fire extinguishers shall be installed to the satisfaction of the [name withheld] mount portable CO2 fire extinguisher in engine room.
46 CFR 181.30-10
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 3 December 2018
Resolved
Wiring joints and splices shall be mechanically secured and made in junction boxes.
Remove or secure in a junction box, dead ended wire above port engine. 46 CFR 183.05-50
05 - Radio Communications › N/A - No Subsystem › Other (radio communication)
Issued 3 December 2018
Resolved
A vessel must comply with the applicable requirements for a station license and installation certificates to be issued by the FCC.
Provide onboard a valid Bridge-to-Bridge safety radio certificate for a vessel over 65' in length. 46 CFR 184.502
09 - Working and Living Conditions › 091 - Living Conditions › Medical Equipment
Issued 3 December 2018
Resolved
Vessel must carry a first aid kit meeting requirements of 46 CFR 160.041.
Replace expired eye wash in first aid kit. 46 CFR 184.710
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 12 September 2018
Resolved
At each initial and subsequent inspection for certification and re-inspection the marine inspector the marine inspector shall examine and test the main and auxiliary steering apparatus to the extent necessary to determine that its condition its satisfactory and that its fit for the service intended. MI observed wasted STBD tiller arm and respective bolts. Additionally, the steering armature was not oriented properly. To be corrected prior to credit DD. iaw 46CFR176.25-35(a.
02 - Structural Conditions › N/A - No Subsystem › Bulkheads - cracking
Issued 12 September 2018
Resolved
Examine all accessible parts of the exterior and interior of the hull, the watertight bulkheads, and the weather deck. MI observed doubler plate repairs in space immediately aft of fore peak. One on aft bulkhead on the port side and two along weld seams on port hull. Submit repair proposal to MI and repair prior to credit DD.
Communications › Radio Communications › VHF Radiotelephone
Issued 29 November 2017
Resolved
MMSI not programmed into vessel's radio. 46CFR184.502
Electrical › Electrical Distribution System (service) › Distribution Panel Bus
Issued 29 November 2017
Resolved
STBD side breaker panel in wheelhouse not labeled properly 46CFR183.220
Communications › Alarms/Indicators › Bilge Alarm
Issued 29 November 2017
Resolved
High water alarm in Lazarette inoperable. 46CFR182.530
Lifesaving › Lifebuoys › Self-igniting Lights
Issued 29 November 2017
Resolved
Water lights on life ring and (3) attached to the lifefloats do not have the correct top fittings for the associated housing it is connected to.
Engineering › Bilge Water Management System › Piping
Issued 29 November 2017
Resolved
Fixed metallic bilge piping has flex hose connections in numerous places throught bilge piping system. 46CFR182.40-5(b) Old T
Construction/Loadline › Hull › Weld
Issued 14 September 2016
Resolved
Repair broken welds where indicated by marine inspector IAW 46 CFR 176.610a
Electrical › Electrical Distribution System (service) › Wiring
Issued 9 September 2016
Resolved
Mast wiring not adequately protected from weather. Properly splice and protect new cable in place IAW 46 CFR 183.05-45
Navigation › Collision/Grounding Avoidance › Navigation Lights
Issued 9 September 2016
Resolved
Navigation lights shield no longer properly colored. Restore to matte black IAW Rules of the Road
Fire Fighting › Fire Hoses › Number
Issued 9 September 2016
Resolved
Replace missing fire hose IAW 46 CFR 181.15-10
Fire Fighting › Fire Main › Condition
Issued 9 September 2016
Resolved
Fire main union and flex hose leaking, port side. Repair leak as original and prove proper operation IAW 46 CFR 181.15
Engineering › Diesel Engine (propulsion-reduction gear) › Turbocharger
Issued 9 September 2016
Resolved
Protect engine exhaust where lagging is missing, port and starboard IAW 46 CFR 182.20-15
Fire Fighting › Fire Main › Pressure
Issued 9 September 2016
Resolved
Replace fire pump discharge pressure gauge; currently inoperable IAW 46 CFR 181.10-1(c)
Fire Fighting › Combustible Materials › Ceilings
Issued 9 September 2016
Resolved
Repair or replace engine room boundary insulation where falling IAW 46 CFR 177.405 (a)
Fire Fighting › Remote Fuel Shutoff › General
Issued 9 September 2016
Resolved
Properly mark location and direction of turn for emergency fuel shutoff IAW 46 CFR 185.608
Stability › Watertight Integrity › General
Issued 9 September 2016
Resolved
Leaking engine room and lazarette hatches. Prove proper water tight seal IAW 46 CFR 171.124
Electrical › Lighting (service) › Switch
Issued 4 September 2015
Resolved
Cover cable box light switches in forepeak and generator space to make watertight. 46CFR183.10-20(f)(3) or (k)
Electrical › Electrical Distribution System (service) › Wiring
Issued 4 September 2015
Resolved
Remove dead-end wires in generator space and space above machinery space. 46CFR183.10-20(a)
Electrical › Electrical Distribution System (service) › Cable
Issued 4 September 2015
Resolved
Remove portable cord plugged into main engine. 46CFR183.10-20(a)(2)
Fire Fighting › Portable CO2 Fire Extinguisher › Mounting Bracket
Issued 4 September 2015
Resolved
Secure both passenger compartment fire extinguishers. 46CFR181.30-10(b)
Lifesaving › Hand Flares › Storage
Issued 4 September 2015
Resolved
Stow distress signals in brightly colored, portable watertight container. 46CFR180.68
Lifesaving › Buoyant Apparatus › Lifeline
Issued 4 September 2015
Resolved
2 lifefloat's grab lines must be repaired to the satisfaction of CG Marine Inspector. 46CFR180.137
Lifesaving › Lifejacket/PFD (General) › Storage
Issued 4 September 2015
Resolved
Properly label lifejacket stowage areas. 46CFR185.604
Fire Fighting › Fire Hoses › Condition
Issued 12 August 2014
Resolved
Fire hose was worn with several holes in it. Hose was destroyed in the presence of Coast Guard inspectors. New hose will be delivered to the vessel tomorrow- before vessel carries passengers. IAW 46 CFR 181.320
Fire Fighting › Fire Hoses › Condition
Issued 30 July 2012
Resolved
Provide repair or replacement for starboard side fire hose IAW 46CFR181.320.
Lifesaving › Lifebuoys › Serviceable
Issued 8 August 2011
Resolved
Repair/replace ring buoys (2) IAW 46CFR180.70
Lifesaving › Lifefloat › Paddle
Issued 8 August 2011
Resolved
Replace broken lifefloat paddles IAW 46CFR180.175
Lifesaving › Lifefloat › Float-free Link
Issued 8 August 2011
Resolved
Replace weak link on all life floats IAW 46CFR180.137
Fire Fighting › Fire Hoses › Connections
Issued 8 August 2011
Resolved
Repair/replace fire hose and gate valve for stbd side IAW 46CFR181.320
Accommodation/Occupational Safety › Medical/First Aid › Medicine Chest
Issued 8 August 2011
Resolved
Replace expired meds in first aid kit IAW 46CFR160.041
Lifesaving › Lifefloat › Floating Electric Waterlight
Issued 8 August 2011
Resolved
Replace expired life float light battery IAW 46CFR180.200
Lifesaving › Lifebuoys › Buoyant Lifeline
Issued 8 August 2011
Resolved
Replace corrosive clip on ring buoy line with non-corrosive clip IAW 46CFR180.70
Electrical › Electrical Distribution System (service) › Non-conducting Deck Covering
Issued 8 August 2011
Resolved
Provide proof of anti-static matting in front of switchboard in engine room IAW 46CFR183.220
Stability › Watertight Integrity › General
Issued 8 August 2011
Resolved
Provide proof that fwd generator spaces aft bulkhead is watertight IAW 46CFR179.212
Stability › Watertight Integrity › General
Issued 8 August 2011
Resolved
Repair/replace valve for fwd peak IAW 46CFR179.360
Electrical › Electrical Distribution System (service) › Wiring
Issued 8 August 2011
Resolved
Provide proof of chafing gear on windlass wiring in fwd peak IAW 46CFR183.220
Electrical › Electric Supply System (service) › Battery Installation
Issued 8 August 2011
Resolved
Provid proof that all battery connections are made permanent IAW 46CFR183.310
Electrical › Electrical Distribution System (service) › Circuit Breaker
Issued 8 August 2011
Resolved
Provide proof of proper labeling of breaker box on fwd bulkhead of engine room IAW 46CFR183.330
Electrical › Electric Supply System (service) › Battery Conductor
Issued 8 August 2011
Resolved
Provide proof that battery swithc is properly mounted IAW 46CFR183.220
Engineering › Fuel Oil Service System › Valve, Control
Issued 27 August 2008
Resolved
MAKE PERMANENT REPAIRS TO REMOTE FUEL SHUTOFF VLV AT NEXT DRYDOCK.
Construction/Loadline › Penetrations › Gasket
Issued 27 August 2008
Resolved
REPLACE GASKETS IN ALL WATERTIGHT HATCHES.
Engineering › Bilge Water Management System › Interface Detector
Issued 5 October 2006
Resolved
REPAIR BILGE ALARM IWO FWD GENERATOR ROOM.
Engineering › Sea-water System (primary cooling) › Pump
Issued 5 October 2006
Resolved
MOUNT WASH DOWN PUMP IWO ENGINE ROOM.
Documentation › Certificates/Documents › FCC SSL
Issued 22 August 2006
Resolved
Provide a FCC Safety Radio Certificate. Certificate expired at the end of May.
Documentation › Certificates/Documents › FCC SSL
Issued 22 August 2006
Resolved
Provide a bridge-to-bridge radio certificate. POC stated that they never had one.
Engineering › Lubricating Oil Service System › Hose
Issued 22 August 2006
Resolved
Repair small hydraulic leaks in hydraulic line for anchor windless IWA FWD void.
Construction/Loadline › Penetrations › Gasket
Issued 22 August 2006
Resolved
Seal all BLKHD penetrations throughout vessel as discussed. They had wires that were loose going through BLKHD's.
Accommodation/Occupational Safety › Occupational Safety › Guards for Exposed Hazards
Issued 22 August 2006
Resolved
Provide a safety shield for the FWD generator pulley assembly and one over the shaft coupler for the FWD bilge pump.
Engineering › Bilge Water Management System › Manifold
Issued 22 August 2006
Resolved
Label valves/system on the FWD bilge manifold. Labels have fadded off.
Engineering › Diesel Engine (propulsion-reduction gear) › Block
Issued 22 August 2006
Resolved
Prior to the carriage of passengers, provide a third party report on the conditions of BMDE's. POC stated that they were having the mechanic come down and look at the STBD engine for a possible blown head gasket. The PORT engine had oil all over the sides and on the OVHD.
Accommodation/Occupational Safety › Occupational Safety › Rubbish/Waste Materials
Issued 22 August 2006
Resolved
Prior to the carriage of passengers, clean all oil from engines, engine room OVHD and bilge.
Engineering › Steering Gear System › Rudder
Issued 22 August 2006
Resolved
Provide rudder stops and replace all wasted metal on steering ram system prior to up-coming ship yard period.
Lifesaving › Lifejacket/PFD (General) › Storage
Issued 22 August 2006
Resolved
Properly label life jacket stowage boxes. (ex: 15 ADULT LIFE PRESERVERS) They just had 15 AD or 15 CH.
Lifesaving › Buoyant Apparatus › Approval
Issued 22 August 2006
Resolved
Prior to the carriage of passengers, provide on ring life buoy. One buoy was wasted.
Engineering › Fuel Oil Service System › Valve
Issued 22 August 2006
Resolved
Label emergency fuel oil valve.
Operations/Management › Drug and Alcohol Testing › Employee Coverage
Issued 22 August 2006
Resolved
Complete all DAPI requirements from audit form. POC had one crew member training onboard that was never pre-tested prior to hire.
Lifesaving › Buoyant Apparatus › Serviceable
Issued 23 May 2005
Resolved
REPAIR OR REPLACE 25 PERSON LIFEFLOAT DROP NET. VESSEL RESTRICTED TO 50 TOTAL PERSONS ON OCEANS ROUTE AND 100 TOTAL PERSONS ON LIMITED COASTWISE ROUTE.
Documentation › Manuals/Policy Documentation › Emergency Instructions
Issued 23 May 2005
Resolved
RE-WRITE EMERGENCY PROCEDURES UNIQUE TO VESSEL OPERATIONS.
Engineering › Fuel Oil Storage/Transfer System › Vent Pipe
Issued 23 May 2005
Resolved
REPLACE FLAME SCREEN ON STBD FUEL VENT.
Operations/Management › Drug and Alcohol Testing › EAP Training Requirements
Issued 23 May 2005
Resolved
POST EAP PHONE #.
Electrical › Electrical Distribution System (service) › Outlet Box
Issued 23 May 2005
Resolved
REPAIR OUTLET BOXES IN GALLEY IN WAY OF COFFEE MAKER.
Engineering › Bilge Water Management System › Piping
Issued 20 September 2004
Resolved
PROVIDE DETAILED PIPING DIAGRAM AND BILGE OPERATION INSTRUCTIONS IN PILOT HOUSE, ENGINE ROOM AND FUEL TANK SPACE.
Documentation › Certificates/Documents › Certificate of Inspection
Issued 20 September 2004
Resolved
Upon review of activity 2183446, noted owner/operator failed to make vesel available for annual inspection w/in 3 months before or after each anniversary date of issuance of the COI. Late annual inspection conducted on activity2168747
Lifesaving › Buoyant Apparatus › Floating Electric Waterlight
Issued 24 August 2004
Resolved
REPLACE BATTERY IN CENTER LIFEFLOAT WATERLIGHT PRIOR TO CARRIAGE OF PASSENGERS.
Engineering › Freshwater Generation System › Piping
Issued 24 August 2004
Resolved
REPLACE HOSE CLAMPS ON FORWARD GENSET EXHAUST PRIOR TO CARRIAGE OF PASSENGERS..
Engineering › Bilge Water Management System › Valve
Issued 24 August 2004
Resolved
LOSEN FORWARD BILGE SUCTION REACH ROD AND INSTALL WRENCH TO OPEN VALVE PRIOR TO CARRIAGE OF PASSENGERS.
Navigation › Piloting/Steering › US Coast Pilot
Issued 24 August 2004
Resolved
UPDATE COAST PILOT AND LIGHT LIST.
Operations/Management › Drills/Instruction
Issued 3 September 2003
Resolved
Prior to the carriage of passengers, conduct a New-To-Zone inspection with MSO Puerto Rico.
Lifesaving › Lifejacket/PFD (Type I) › Retroreflective Material
Issued 26 August 2003
Resolved
REPLACE RETRO ON 06 ADULT TYPE I LIFEJACKETS PRIOR TO CARRIAGE OF PASSENGERS.
Lifesaving › Buoyant Apparatus
Issued 26 August 2003
Resolved
REPAIR MIDDLE LIFEFLOAT HAND ROPE BRACKET. LEGACY COMPONENT DESC: Bracket
Engineering › Steering Gear System › Hydraulic Hose
Issued 26 August 2003
Resolved
REPAIR INBOARD HYDRAULIC LINE FITTING ON STEERING SYSTEM.
Engineering › Steering Gear System
Issued 26 August 2003
Resolved
REPAIR HYDRAULIC RAM OUTBOARD FITTING. LEGACY COMPONENT DESC: Ram Seal
Engineering › Bilge Water Management System
Issued 26 August 2003
Resolved
INSTALL GUARD ON BILGE PUMP PULLEY. LEGACY COMPONENT DESC: Pump
Deck/Cargo › Holds/Tanks
Issued 26 August 2003
Resolved
LABEL EMERGENCY ESCAPE HATCHES IN ENGINE ROOM. LEGACY COMPONENT DESC: Hatch Cover
Engineering › Fuel Oil Storage/Transfer System
Issued 26 August 2003
Resolved
REPAIR EMERGENCY FUEL STOP PRIOR TO CARRIAGE OF PASSENGERS. LEGACY COMPONENT DESC: Valve
Engineering › Bilge Water Management System
Issued 26 August 2003
Resolved
REPAIR FWD BILGE REACH ROD PRIOR TO CARRIAGE OF PASSENGERS. LEGACY COMPONENT DESC: Valve
Lifesaving › Buoyant Apparatus
Issued 3 September 2002
Resolved
PROPERLY INSTALL SEA PAINTER/WEAK LINK/TEATHER LINES ON LIFEFLOATS PRIOR TO CARRIAGE OF PASSENGERS.
Lifesaving › Buoyant Apparatus
Issued 3 September 2002
Resolved
REPLACE HAND LINE ON UPPER LIFEFLOAT PRIOR TO CARRIAGE OF PASSENGERS.
Electrical › Electrical Distribution System (service)
Issued 3 September 2002
Resolved
REPLACE STANDARD HOUSEHOLD WIRING UNDER SINK OUTLET AND EXHAUST VENT. LEGACY COMPONENT DESC: Wiring
Lifesaving › Lifejacket/PFD (Type IV)
Issued 3 September 2002
Resolved
REPLACE 1 LIFERING PRIOR TO CARRIAGE OF PASSENGERS. LEGACY COMPONENT DESC: Condition
Electrical › Lighting (service)
Issued 3 September 2002
Resolved
INSTALL DIFFUSERS ON OVERHEAD LIGHTING IN BOTH HEADS. LEGACY COMPONENT DESC: Neutral Bus
Lifesaving
Issued 4 June 2001
Resolved
PRIOR TO CARRIAGE OF PASENGERS, REPLACE 24" RING BOUY.
Unknown
Issued 4 June 2001
Resolved
UPDATE COPIES OF LIGHT LIST, COAST PILOT, NAVIGATION RULES, AND TIDES & CURRENTS.
Lifesaving
Issued 4 June 2001
Resolved
PRIOR TO CARRIAGE OF PASSENGERS, RENEW 6 RED HAND HELD FLARES.
Construction/Loadline
Issued 4 June 2001
Resolved
REPAIR SLICE IN AFT BILGE SUCTION LINE.
Lifesaving
Issued 22 May 2000
Resolved
INSTALL AID TO ASSIST IN RECOVERY OF HELPLESS PERSON FROM WATER AND DEMONSTRATE MAN OVERBOARD PROCEDURES.
Lifesaving
Issued 22 May 2000
Resolved
REMOVE SILICONE FROM EMERGENCY ESCAPE HATCHES AND PROPERLY STENCIL "EMERGENCY ESCAPE, KEEP CLEAR".
Construction/Loadline
Issued 22 May 2000
Resolved
REPAIR FWD BILGE SUCTION REACH ROD AND PROPERLY STENCIL WITH ARROW IN DIRECTION OF CLOSURE.
Engineering
Issued 22 May 2000
Resolved
REPAIR FLAME SCREEN IN FUEL VENT.
Engineering
Issued 22 May 2000
Resolved
REPAIR PORT MAIN JACKET WATER TEMPERATURE GAUGE.
Lifesaving
Issued 17 May 1999
Resolved
POST PFD DONNING INSTRUCTIONS FOR ALL TYPES OF PFD'S ON BOARD._x001C_ _x001C_ _x001C_ _x001C_
Navigation
Issued 17 May 1999
Resolved
PROVIDE CURRENT COPIES OF NAVIGATION RULES, CG LIGHT LIST, COAST PILOT, TIDE/CURRENT TABLES AND CORRECTED CHARTS._x001C_ _x001C_ _x001C_
Lifesaving
Issued 17 May 1999
Resolved
REPAINT/RELABEL ALL LIFEFLOATS._x001C_ _x001C_ _x001C_ _x001C_
Engineering
Issued 17 May 1999
Resolved
DOUBLE CLAMP ALL RAW WATER HOSES ON FWD. GENERATOR._x001C_ _x001C_ _x001C_ _x001C_
Electrical
Issued 17 May 1999
Resolved
INSTALL COVER ON LIGHT FIXTURE AT ENGINEROOM ENTRANCE._x001C_ _x001C_ _x001C_ _x001C_
Construction/Loadline
Issued 9 April 1997
Resolved
V AND WELD CRACKED WELD IN #2 COMPT. PORTSIDE CHINE AT FWD BULKHEAD AS MARKED. NO PASSENGERS FOR HIRE UNTIL CLEARED.
Electrical
Issued 18 November 1996
Resolved
INSTALL A MAIN DISCONNECT SWITCH FOR THE STARTING BATTERIES CONNECTED TO THE DIESEL GENERATORS.
Construction/Loadline
Issued 18 November 1996
Resolved
PROVIDE A STUFFING TUBE FOR THE CONTROL WIRING FOR THE FWB DECK CAPSTAIN WHERE IT PENETRATES THE PORT SIDE OF THE # 3 BHD.
Engineering
Issued 18 November 1996
Resolved
INSTALL LAGGING ON FWD DIESEL GENERATOR'S EXHAUST PIPE.
Fire Fighting
Issued 18 November 1996
Resolved
PROVIDE 2 ADDITIONAL BII FIRE EXTINGUISHERS FOR THE DIESEL GENERATOR SPACE.
Construction/Loadline
Issued 25 January 1995
Resolved
IN ENG RM U/W CRACKED WELDS IN FRAMES #2 & #4, PORT SIDE, IWO MAIN DECK.
Construction/Loadline
Issued 25 January 1995
Resolved
IN ENG RM V/W CRACKED WELD ON FRAME #2 IWO #2 SSL.
Construction/Loadline
Issued 25 January 1995
Resolved
IN LAZARETTE V/W AROUND FRESH WATER INTAKE & MAIN DECK._x001C_ _x001C_
Construction/Loadline
Issued 25 January 1995
Resolved
IN LAZARETTE V/W CRACKED WELD ON #4 DECK LONG & #2 DECK TRANSV.
Construction/Loadline
Issued 25 January 1995
Resolved
IN LAZERETTE V/W CRACKED WELD IN #2 DECK TRANS, IWO SSL #2 (STBD).
Construction/Loadline
Issued 25 January 1995
Resolved
IN LAZARETTE V/W CRACKED WELD AFT OF #2 FRAME IN STBD SIDE.
Construction/Loadline
Issued 25 January 1995
Resolved
V/W CRACKED WELD IN BAY 3 AT #7SSL IN FOREPEAK.
Construction/Loadline
Issued 25 January 1995
Resolved
V/W CRACKED WELD IN BAY 3 AT #7 SSL IWO FRAME #3 IN FORPEAK.
Construction/Loadline
Issued 13 April 1994
Resolved
IN 3RD COMPARTMENT STBD SIDE VEE & WELD CRACKED WELD IWO #5 FRAME AND DEEP WEB LONG.
Construction/Loadline
Issued 13 April 1994
Resolved
IN 3RD COMPARTMENT PORTSIDE VEE & WELD CRACKED WELDS IWO #3, 4, & 6 FRAME_x001C_ AND DEEP WEB LONG.
Construction/Loadline
Issued 26 October 1992
Resolved
MAKE VESSEL AVAILABLE FOR CREDIT DRYDOCK EXAM NO LATER THAN 31MAR93.
Construction/Loadline
Issued 4 April 1991
Resolved
REPAIR FRACTURES #2 COMPT (A) TOP OF STANTION #2 ON STB SIDE (B) FWD OF PORT BOTTOM LONGITUDINAL (3) 3 COMPT, BOTTOMING OF STANTION PORT SIDE AND AT FRAME NEAR BOTTOM OF STANTION
Navigation
Issued 27 March 1989
Resolved
PROVIDE CURRENT ISSUES OF SAILING DIRECTIONS, COAST PILOT, LIGHT LIST (USCG) AND NAV RULES.
Navigation
Issued 27 March 1989
Resolved
PROVIDE PROPER FIXTURES FOR ALL NAVIGATION LIGHTS I/A/W NAVRULES/CO/REGS.
Fire Fighting
Issued 27 March 1989
Resolved
PROVIDE DISCHARGE SIDE PRESSURE GAUGE FOR ELECTRIC FIRE PUMP: I/A/N
Electrical
Issued 27 March 1989
Resolved
WHERE BROKEN PROVIDE OPERATIONAL TEST OF LIGHT SWITCH FOR LAZARETTE.
Electrical
Issued 24 March 1988
Resolved
MAKE NECESSARY CHANGES TO VESSEL'S DC WIRING TO PROVIDE OVER-CURRENT PROTECTION FOR THE WIRING BETWEEN THE ENGINE ROOM AND THE BRIDGE.
Construction/Loadline
Issued 24 March 1988
Resolved
REPAIR FRACTURES TO PORT & STBD RUDDER POST TUBE REINFORCING GUSSETS.
Construction/Loadline
Issued 24 March 1988
Resolved
REPAIR FRACTURE PORT SIDE CHINE AFT OF COLLISION BHD.
Construction/Loadline
Issued 24 March 1988
Resolved
REPAIR FRACTURES TO BOTTOM FRAMING IN #3 & #5 COMPARTMENTS AS MARKED.
Casualty record · 2
29 January 2010Routine · role: Involved in a Marine Casualty · activity 3680474
26 August 2017Routine · role: Involved in a Marine Casualty · serious marine incident, as classified · 1 injured · activity 6255993
Each line is an incident investigation the Coast Guard recorded with this hull among the vessels involved, with the date and the classification the Coast Guard gave it, and the bridge, lock or dam the investigation names where it names one. Involvement is not fault. The investigation narrative is not published. Source: IIR, through 2026.