FLYING FISH is a 1974 passenger vessel (inspected). The Coast Guard has recorded 72 inspections since 1985, most recently in March 2026, along with 163 deficiencies — 1 with no resolution recorded — and 2 casualty investigations between 2010 and 2017.

Records from 1985 to 2026. Most recent: inspection, 13 March 2026.

Built
1974
Last inspected
13 March 2026
Documentation
Valid · documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

WDL8110
Flag
UNITED STATES
367447080
Maury page id
psix-47909

Inspections, by type

…with no type recorded6
Years with a record 39 calendar years (1985–2026)
The 72 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Passenger Ship class in Maury's sources begin in 1977.

Documentation record

Registered dimensions (L × B × D)73.8 ft × 22.0 ft × 7.1 ft
Registered tonnagegross 66 / net 45
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
BuilderGULF CRAFT INC · PATTERSON, LA, UNITED STATES · built 1974
Hull materialAluminum
PropulsionDiesel Reduction
Hull shapeNot recorded
Hull configurationNot recorded
Hailing portSARASOTA, FL
Trade endorsementsCoastwise, unrestricted, Fishery, Recreational
DocumentationValid · issued 21 August 2025 · expires 31 August 2026
Service, as the file records itPassenger (Inspected)
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it66 - Regulatory (Subpart C or D), Gross Ton
45 - Regulatory (Subpart C or D), Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 September 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.

Radio station licence

WDL8110MMSI 367447080 · active · compulsorily equipped · granted 15 October 2020, expires 15 October 2030
WDF4031MMSI 367447080 · expired · compulsorily equipped · granted 13 April 2010, cancelled 13 June 2020
WCZ7517MMSI not assigned · expired · compulsorily equipped · granted 12 April 2000, cancelled 12 June 2010
WBP4734MMSI not assigned · expired · compulsorily equipped · granted 18 December 1997, cancelled 22 March 2008 · licensed under a name not among this hull’s recorded names (not shown)
FCC Universal Licensing System ship-station file of 6 September 2026, matched to this hull on its US Official Number. Status and dates are the file’s own. The licensee is not read from the file and is not shown. A lapsed licence’s MMSI is still the number the vessel transmitted under while it was valid.

Inspection history · 72

13 March 2026 Administrative Inspection · Deficiency Check · COI Inspection
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 8317487
8 April 2025 Drydock Exam · Administrative Inspection · Internal Structural Exam · Vessel Attendance · Examination of Repairs
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 8086800
20 November 2024 Annual Inspection
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 8026265
13 November 2023 Annual Inspection · Deficiency Check
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 7810006
3 April 2023 Deficiency Check · Annual Inspection
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 7593999
4 October 2022 In-Service Inspection · Administrative Inspection · Hull Examination · Internal Structural Exam · Examination of Repairs
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 7571165
16 November 2021 Annual Inspection · Deficiency Check
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 7352375
27 August 2020 Drydock Exam · Internal Structural Exam
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 7024104
26 August 2020 COI Inspection · Deficiency Check · DAPI Audit
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 7024096
31 October 2019 Annual Inspection · DAPI Audit · Examination of Repairs · Administrative Inspection
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 6840614
3 December 2018 DAPI Audit · Administrative Inspection · Deficiency Check · Annual Inspection · Examination of Repairs
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 6586713
12 September 2018 Hull Examination · Internal Structural Exam · Administrative Inspection · Examination of Repairs
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 6533338
14 November 2017 Annual Inspection
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 6306780
26 August 2017 Type not recorded
No type recorded · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 6255993
9 September 2016 Annual Inspection · Deficiency Check · Drydock Exam · Internal Structural Exam
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 5979745
4 September 2015 DAPI Audit · Deficiency Check · COI Inspection
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 5232010
27 August 2014 Drydock Exam · Internal Structural Exam
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 4967013
12 August 2014 Annual Inspection · Deficiency Check · DAPI Audit
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 4952898
30 July 2012 Administrative Inspection · Annual Inspection · DAPI Audit · Deficiency Check
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 4396135
8 August 2011 Annual Inspection · Administrative Inspection
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 4119697
22 October 2010 Internal Structural Exam · Administrative Inspection · Hull Examination
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 3874290
29 January 2010 Type not recorded
No type recorded · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 3680474
17 September 2008 Hull Examination
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 3326612
27 August 2008 Deficiency Check · Annual Inspection
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 3310063
5 October 2006 Hull Examination
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 2778130
22 August 2006 Deficiency Check · Annual Inspection
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 2750753
23 May 2005 Deficiency Check · COI Inspection
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 2362615
20 September 2004 Deficiency Check · Examination of Repairs · Hull Examination
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 2183446
24 August 2004 Annual Inspection
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 2168747
16 September 2003 Deficiency Check
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1895810
26 August 2003 Annual Inspection
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1873579
5 December 2002 Hull Examination
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1705442
3 September 2002 Annual Inspection
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1664889
23 August 2001 Deficiency Check
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1072453
4 June 2001 Re-Inspection
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1382280
5 February 2001 Deficiency Check
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1056581
21 August 2000 Deficiency Check
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 821163
22 May 2000 COI Inspection
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1421877
31 May 1999 Deficiency Check
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1110779
17 May 1999 Re-Inspection
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1384143
17 December 1998 Type not recorded
No type recorded · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 806803
1 December 1998 Hull Examination
Physical examination · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 1106562
29 September 1998 Type not recorded
No type recorded · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 228709
24 June 1998 Administrative
Administrative · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 1127687
17 April 1998 COI Inspection
Physical examination · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 789621
9 April 1997 Re-Inspection · MARPOL Annex V Examination
Physical examination · GROUP/MSO LONG ISLAND SOUND · USCG Northeast District (CGD-NE) · Activity 1103186
20 March 1997 Type not recorded
No type recorded · GROUP/MSO LONG ISLAND SOUND · USCG Northeast District (CGD-NE) · Activity 1103213
18 November 1996 Hull Examination
Physical examination · GROUP/MSO LONG ISLAND SOUND · USCG Northeast District (CGD-NE) · Activity 1398793
9 April 1996 MARPOL Annex V Examination · COI Inspection
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1079731
10 April 1995 MARPOL Annex V Examination · COI Inspection
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1155226
8 February 1995 Deficiency Check
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 843036
25 January 1995 Hull Examination
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1142265
13 April 1994 COI Inspection · MARPOL Annex V Examination
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1168780
15 April 1993 COI Inspection
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 832081
30 March 1993 Hull Examination
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 837262
26 October 1992 Drydock Extension
Administrative · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 938555
10 April 1992 COI Inspection
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 953445
4 April 1991 Hull Examination
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 902348
26 March 1991 Administrative
Administrative · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1219422
26 March 1991 COI Inspection
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1219591
27 March 1990 COI Inspection
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 924123
1 November 1989 Deficiency Check · Hull Examination
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 907015
19 June 1989 Deficiency Check
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1038694
27 March 1989 COI Inspection
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1343960
10 October 1988 Deficiency Check
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1035493
31 March 1988 COI Inspection
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1034406
24 March 1988 Hull Examination · Plan Review "T" Boat
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1040419
26 March 1987 Hull Examination
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1325262
18 March 1987 COI Inspection
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1016309
28 March 1986 Credit Drydock
Administrative · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 997896
21 March 1986 COI Inspection
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1304756
22 March 1985 Type not recorded
No type recorded · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1289671

Deficiency record · 163

07 - Fire Safety › N/A - No Subsystem › Fixed fire extinguishing installation
Issued 13 March 2026 Resolved
S and L. If 1 1/2 inch fire hose is used after January 1, 1980 then each length of hose must be lined commercial fire hose that conforms to UL19 or ZZ-H-451E. A hose that bears the Label of Underwriters' Laboratories, Inc. as lined fire hose is accepted. MI observed no marking of conformity that aligned with requirements. Replace hose on-board with conforming hose standards. 46CFR181.15-10(d)(1) 16c
Action required: 16 - Rectify deficiencies w/in 14 days
Due 27 March 2026
Resolved 28 April 2026
Resolution: Operator provided proof of approved hose for use in fire fighting.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 13 March 2026 Resolved
A vessel of more than 65 feet in length must carry a minimum of three life buoys of not less than 24 in. in diameter. MI observed one ring life buoy of 20 in. in diameter of the three required and available onboard. Replace 20 in. life buoy with 24 in. life buoy and provide photographic evidence of all three required buoys in single capture. 46CFR180.70(a)(3) 16c
Action required: 16 - Rectify deficiencies w/in 14 days
Due 27 March 2026
Resolved 13 April 2026
Resolution: Operator provided proof of correctly sized lifebuoys.
07 - Fire Safety › N/A - No Subsystem › Fixed fire extinguishing installation
Issued 13 March 2026 Resolved
On a vessel of more thn 65 feet in length the minimum capacity of the fire pump must be 50 gallons per minute at a pressure of not more than 60 psi at the pump outlet. MI observed psi at 25-27 psi at the pump outlet for the 4-5 minute duration of the fire pump in operation. Ensure pressure meets requirement. 46CFR181.300(b) 16c
Action required: 16 - Rectify deficiencies w/in 14 days
Due 27 March 2026
Resolved 13 April 2026
Resolution: Operator provided proof of adequate pressure on the fire hose after rebuild of fire pump.
04 - Emergency Systems › N/A - No Subsystem › Emergency, lighting, batteries and switches
Issued 13 March 2026 Resolved
Electrical equipment on a vessel must be installed and maintained to: Minimize accidental personnel contact with energized parts. Make repair to electrical wiring in #3 void forward and install appropriate bulb/cover in engine room light fixture. 46 CFR 183.200 16c
Action required: 16 - Rectify deficiencies w/in 14 days
Due 27 March 2026
Resolved 28 April 2026
Resolution: Operator provided proof of lighting fixture replaced along with repair to damaged cable.
04 - Emergency Systems › N/A - No Subsystem › Public address system
Issued 13 March 2026 Resolved
On a vessel of more than 65 feet in length, the PA system must be a fixed installation and audible during normal operating conditions throughout the accommodation spaces and all other spaces normally manned by crew members [name withheld] system to be audible thru out all accommodation space or plan for effective communication, ie. walkie talkies.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 27 March 2026
Resolved 28 April 2026
Resolution: Operator provided proof of walkie talkies for use onboard the vessel for crewmembers.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 6 October 2025 No resolution recorded
No major repairs or alterations affecting the safety of the vessel with regard to hull, machinery, or equipment shall be made without the knowledge and apprioval of [name withheld] noticed two battery chargers were installed without permanent wiring. Provide wiring diagram for the vessel. 46CFR(old) 176.20-1(a)
Action required: 705 - Other - as specified
01 - Certificates & Documentation › 011 - Ships Certificates › Certificate of Inspection (COI)
Issued 21 May 2025 Resolved
A vessel that is exposed to salt water more than three months in any 12 month period since the last examination must undergo a drydock examination and an internal structural at least once every two years. Vessel dry dock inspection drop dead date is 31MAR2025. Vessel must undergo a satisfactory dry dock and internal structural exam prior to the carriage of passengers. 46 CFR 176.600(c)(1)
Action required: 701 - Prior to carriage of passengers/cargo
Due 21 May 2025
Resolved 2 December 2025
Resolution: Completed Credit Drydock.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 13 November 2023 Resolved
An adult life jacket must be provided for each person carried on board a vessel. Vessel is missing one adult life jacket. Maximum passenger count is reduced to 71. 46CFR180.71(a)
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 13 November 2023
Resolved 4 December 2023
Resolution: New adult life jacket purchased with proper marking and retro. Max pax count raised to 72.
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 13 November 2023 Resolved
Each portable fire extinguisher on a vessel must be of an approved type. The minimum number of portable fire extinguishers required on a vessel must be acceptable to the OCMI but must not be fewer than the minimum number required by Table 181.500(b). MIs found the 80B:C portable fire extinguisher located in the wheelhouse to be low on charge. 46CFR181.500(a)
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 27 November 2023
Resolved 4 December 2023
Resolution: Fire extinguisher recharged.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 13 November 2023 Resolved
At least one ring life buoy must be fitted with a lifeline. MIs observed the lifeline on the aft ring life buoy to be deteriorated. 46CFR180.70(c)
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 27 November 2023
Resolved 7 February 2024
Resolution: Vessel rep provided picture of life ring with proper life line attached.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Railing, gangway, walkway and means for safe passage
Issued 13 November 2023 Resolved
An exposed hazard, such as gears or rotating machinery, must be properly protected by a cover, guard, or rail. MIs observed the guards on both main engines to be removed exposing the rotating machinery. 46CFR177.960
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 27 November 2023
Resolved 4 December 2023
Resolution: Guards installed on both engines.
11 - Life Saving Appliances › N/A - No Subsystem › Operational readiness of lifesaving appliances
Issued 3 April 2023 Resolved
Each life float must be fitted with a lifeline, pendants, two paddles, a painter, and a light. The three lifefloats were found with corroded and broken paddles. 46 CFR 180.175(d)
Action required: 705 - Other - as specified
Due 10 April 2023
Resolved 9 April 2023
Resolution: The operator purchased two new paddles for each life float and labelled them IAW regulations.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 3 April 2023 Resolved
In damp or wet locations, the cable entrance shall be watertight. The weather exposed light housing located on the aft main deck was found with an un-sealed cable entrance. 46 CFR 183.10-20(f)(3)
Action required: 705 - Other - as specified
Due 10 April 2023
Resolved 9 April 2023
Resolution: The cable entrance was found sealed using a marine putty designed for sealing electrical junction boxes.
01 - Certificates & Documentation › 011 - Ships Certificates › Certificate of Inspection (COI)
Issued 4 October 2022 Resolved
A vessel that is exposed to salt water more than three months in any 12 month period since the last examination must undergo a drydock examination and an internal structural at least once every two years. MI discovered the valid DD period ended on 30Sep2022. 46 CFR 176.600 (c)(1)
Action required: 50 - Rectify deficiencies w/in 30 days
Due 13 November 2022
Resolved 3 April 2023
Resolution: The owner completed dry dock credit on April 3, 2023.
10 - Safety of Navigation › N/A - No Subsystem › Lights, shapes, sound-signals
Issued 16 November 2021 Resolved
10109 - All vessels must have navigation lights, a vessel of more than 19.8 meters (65 feet) in length must also have navigation lights that meet UL 1104. Navigation lights did not meet UL 1104. - 46 CFR 183.420 - 16C
Action required: 16 - Rectify deficiencies w/in 14 days
Due 30 November 2021
Resolved 7 December 2021
Resolution: Vessel representative purchased UL1104 lightbulbs.
07 - Fire Safety › N/A - No Subsystem › Fire pumps and its pipes
Issued 26 August 2020 Resolved
A power-driven fire pump shall be installed on each mechanically propelled "L" vessel. Repair or replace inoperable fire pump. 46CFR181.10-1(a)"Old T"
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 9 October 2020
Resolution: Master repaired inoperable fire pump.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 26 August 2020 Resolved
All vessels shall be provided with a satisfactory arrangement for draining any watertight compartment other than small buoyancy compartments, under all practical conditions. Ensure proper drainage of lazarette space. 46CFR182.25-1(a)"Old T"
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 8 October 2020
Resolution: Master demonstrated proper drainage of lazarette.
11 - Life Saving Appliances › N/A - No Subsystem › Rigid liferafts
Issued 26 August 2020 Resolved
A life float—Approved under approval series 160.027 and be in good serviceable condition. Life floats were missing manufacture placards and multiple fasteners for the lifeline and pennants were broken. Replace/renew life floats to meet the requirements of 46CFR160.027
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 9 September 2020
Resolved 8 October 2020
Resolution: Placard information was stenciled on life rafts. Fasteners were repaired. Wooden platforms replaced.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 26 August 2020 Resolved
Each child and adult size life jacket must be stowed in a location that is appropriately marked and separated, so the child size life jackets are not mistaken for adult life jackets. Life Jacket stowage locations were not marked. 46CFR180.200(a)(5)
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 9 September 2020
Resolved 8 October 2020
Resolution: Stowage bins for lifejackets were marked with stickers.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 26 August 2020 Resolved
An adult life jacket must be provided for each person carried on board a vessel. 5 adult life jackets were unserviceable and 2 adult life jackets and 2 child life jackets had unserviceable retro-reflective tape. Replace unserviceable jackets and replace retro-reflective tape as needed. 46CFR180.71(a)
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 9 September 2020
Resolved 8 October 2020
Resolution: Unservicable lifejackets replaced and retro replaced.
10 - Safety of Navigation › N/A - No Subsystem › Lights, shapes, sound-signals
Issued 26 August 2020 Resolved
All vessels must have navigation lights that are in compliance with the applicable sections of the International and Inland Navigation Rules. Repair or replace navigation lights. 46CFR183.420
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 9 September 2020
Resolved 8 October 2020
Resolution: Nav lights replaced and shine brightly.
10 - Safety of Navigation › N/A - No Subsystem › Charts
Issued 26 August 2020 Resolved
As appropriate for the intended voyage, a vessel must carry adequate and up-to-date charts of large enough scale to make safe navigation possible. Provide up-to-date charts of sufficient scale. 46CFR184.420
Condition: Invalid
Action required: 16 - Rectify deficiencies w/in 14 days
Due 9 September 2020
Resolved 8 October 2020
Resolution: Up-to-date chart procured and onboard.
04 - Emergency Systems › N/A - No Subsystem › Man Overboard Drill (MOB)
Issued 26 August 2020 Resolved
The master shall conduct sufficient drills and give sufficient instructions to make sure that all crew members are familiar with their duties during emergencies that necessitate abandoning ship or the recovery of persons who have fallen overboard. Conduct man overboard drill to the satisfaction of the attending marine inspector. 46CFR185.520(a)
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 9 September 2020
Resolved 8 October 2020
Resolution: MOB drill conducted to satisfaction of MI.
09 - Working and Living Conditions › 092 - Working Conditions › Lighting (Working spaces)
Issued 26 August 2020 Resolved
Electrical equipment on a vessel must be installed and maintained to provide services necessary for safety under normal and emergency procedures. The vessel’s engine room did not have adequate lighting. Repair or replace. 46CFR185.524(a)
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 9 September 2020
Resolved 8 October 2020
Resolution: Engine room lighting replaced and shining brightly.
04 - Emergency Systems › N/A - No Subsystem › Fire drills
Issued 26 August 2020 Resolved
The master shall conduct sufficient fire drills to make sure that each crew member is familiar with his or her duties in case of a fire. Conduct fire drill to the satisfaction of the attending marine inspector. 46CFR183.200(a)
Condition: Invalid
Action required: 16 - Rectify deficiencies w/in 14 days
Due 9 September 2020
Resolved 8 October 2020
Resolution: Fire drill conducted to satisfaction of MI.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 26 August 2020 Resolved
Electrical equipment on a vessel must be installed and maintained to protect passengers, crew, or other persons and the vessel from electrical hazards, including fire, caused by or originating in electrical equipment, and electrical shock. Loose and dead end wires were observed throughout the engine room. 46CFR183.200(b)
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 9 September 2020
Resolved 8 October 2020
Resolution: Loose and dead end wires capped and secured.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 26 August 2020 Resolved
The marine employer shall ensure that all persons directly involved in a serious marine incident are chemically tested for evidence of dangerous drugs and alcohol. Alcohol test strips used for testing within 2 hours of a serious marine incident are expired. Replace. 46CFR16.240
Condition: Invalid
Action required: 16 - Rectify deficiencies w/in 14 days
Due 9 September 2020
Resolved 8 October 2020
Resolution: New alcohol test strips purchased and onboard.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 26 August 2020 Resolved
By March 15 of the year following the collection of the drug testing program data, marine employers must submit the data on the MIS Date Collection Form. Missing 2019 MIS report. Provide 2019 MIS report to ensure submission of data within the specified time frame. 46CFR16.500(b)
Condition: Invalid
Action required: 16 - Rectify deficiencies w/in 14 days
Due 9 September 2020
Resolved 8 October 2020
Resolution: Owner produced 2019 MIS report.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 26 August 2020 Resolved
Protect passengers, crew, other persons, and the vessel from electrical hazards, including fire, caused by or originating in electrical equipment, and electrical shock. Exposed wires were observed on the electrical shore tie. Repair/Replace shore tie. 46CFR183.200(b)
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 9 September 2020
Resolved 8 October 2020
Resolution: Exposed wires on shore tie repaired.
05 - Radio Communications › N/A - No Subsystem › MF Radio installation
Issued 26 August 2020 Resolved
Vessels operated beyond the 20 nautical mile limitation specified in paragraph (a)(1) of this section, but not more than 100 nautical miles from the nearest land, must be equipped with a MF–DSC frequency transmitter meeting the requirements of § 80.1101(c)(3) Vessel has an Oceans route not more the 100 miles and is operating without a MF–DSC frequency transmitter. Vessel route is restricted to coastwise till MF radio is installed and certified. 47CFR80.905(a)(2)
Condition: Invalid
Action required: 16 - Rectify deficiencies w/in 14 days
Due 9 September 2020
Resolved 17 November 2020
Resolution: Updated route to coastwise. MF radio no longer required.
05 - Radio Communications › N/A - No Subsystem › Other (radio communication)
Issued 26 August 2020 Resolved
A vessel must comply with the applicable requirements for any radio installations including the requirements for a station license to be issued by the FCC. Renew expired FCC Station License. 46CFR184.502
Condition: Invalid
Action required: 16 - Rectify deficiencies w/in 14 days
Due 9 September 2020
Resolved 17 November 2020
Resolution: Vessel owner emailed copy of renewed Station License.
05 - Radio Communications › N/A - No Subsystem › Other (radio communication)
Issued 26 August 2020 Resolved
Every vessel subject to Part II or Title III of the Communications Act must have a detailed inspection of the radio installation by an FCC-licensed technician to receive a Communications Act Safety Radiotelephony Certificate. Obtain a new Safety Radiotelephony Certificate after installing MF radio. 47CFR80.903
Condition: Invalid
Action required: 16 - Rectify deficiencies w/in 14 days
Due 9 September 2020
Resolved 17 November 2020
Resolution: Updated route to coastwise. MF radio no longer required.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 31 October 2019 Resolved
All vessels shall be provided with bilge pumps in accordance with Table 182.25-10(a) - old T. Make repairs and prove operation of secondary engine driven bilge pump servicing forward compartments and secondary engine driven bilge pump servicing aft compartments. 46CFR182.25-10 (old T).
Action required: 16 - Rectify deficiencies w/in 14 days
Due 14 November 2019
Resolved 1 December 2019
Resolution: Operator installed new pumps.
07 - Fire Safety › N/A - No Subsystem › Fire pumps and its pipes
Issued 31 October 2019 Resolved
Make repairs to leaking port side fire main riser at deck valve as identified. All piping, valves, and fittings shall be in accordance with good marine practice and suitable for the purpose intended. 46CFR181.15-5(c) (old T).
Action required: 16 - Rectify deficiencies w/in 14 days
Due 14 November 2019
Resolved 1 December 2019
Resolution: Operator completed satisfactory weld repair.
07 - Fire Safety › N/A - No Subsystem › Fire pumps and its pipes
Issued 3 December 2018 Resolved
A power driven fire pump shall discharge a minimum capacity of 50 gpm at a pressure not less than 60 psi at the pump outlet. Prove proper fire pump capacity. 46 CFR 181.10-1
Action required: 16 - Rectify deficiencies w/in 14 days
Due 17 December 2018
Resolved 24 January 2019
Resolution: Pump replaced and observed 70 PSI at gauge and witnessed good stream at nozzle.
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 3 December 2018 Resolved
All electrical equipment shall be drip proof protected Provide drip proof material above electrical components in forward engine room. 46 CFR 183.10-10
Action required: 16 - Rectify deficiencies w/in 14 days
Due 17 December 2018
Resolved 19 December 2018
Resolution: Operator installed drip shields.
02 - Structural Conditions › N/A - No Subsystem › Ballast, fuel and other tanks
Issued 3 December 2018 Resolved
At each initial and subsequent inspection for certification the marine inspector shall examine and test the following items to the extent necessary to determine that they are in proper operating condition and fit for service intended. Repair or replace hydraulic sight glass on hydraulic tank in engine room. 46 CFR 176.25-10
Action required: 16 - Rectify deficiencies w/in 14 days
Due 17 December 2018
Resolved 19 December 2018
Resolution: Operator replaced hydraulic tank sight glass and hose clamp.
02 - Structural Conditions › N/A - No Subsystem › Closing devices/watertight doors
Issued 3 December 2018 Resolved
All escape hatches and other emergency exits shall be marked on both sides using at least one inch letters, "EMERGENCY EXIT, KEEP CLEAR". Mark engine room escape hatch as required above. 46 CFR 185.30-15
Action required: 16 - Rectify deficiencies w/in 14 days
Due 17 December 2018
Resolved 20 December 2018
Resolution: Verified operator installed emergency exit signes.
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 3 December 2018 Resolved
Portable fire extinguishers shall be installed to the satisfaction of the [name withheld] mount portable CO2 fire extinguisher in engine room. 46 CFR 181.30-10
Action required: 16 - Rectify deficiencies w/in 14 days
Due 17 December 2018
Resolved 20 December 2018
Resolution: Verified operator mounted fire extinguisher.
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 3 December 2018 Resolved
Wiring joints and splices shall be mechanically secured and made in junction boxes. Remove or secure in a junction box, dead ended wire above port engine. 46 CFR 183.05-50
Action required: 16 - Rectify deficiencies w/in 14 days
Due 17 December 2018
Resolved 20 December 2018
Resolution: Verified operator mechanically secured dead ended wire in engine room.
05 - Radio Communications › N/A - No Subsystem › Other (radio communication)
Issued 3 December 2018 Resolved
A vessel must comply with the applicable requirements for a station license and installation certificates to be issued by the FCC. Provide onboard a valid Bridge-to-Bridge safety radio certificate for a vessel over 65' in length. 46 CFR 184.502
Action required: 16 - Rectify deficiencies w/in 14 days
Due 17 December 2018
Resolved 19 December 2018
Resolution: Verified current Bridge-to-Bridge certificate.
09 - Working and Living Conditions › 091 - Living Conditions › Medical Equipment
Issued 3 December 2018 Resolved
Vessel must carry a first aid kit meeting requirements of 46 CFR 160.041. Replace expired eye wash in first aid kit. 46 CFR 184.710
Action required: 16 - Rectify deficiencies w/in 14 days
Due 17 December 2018
Resolved 19 December 2018
Resolution: Operator purchased new eye wash for first aid kit.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 12 September 2018 Resolved
At each initial and subsequent inspection for certification and re-inspection the marine inspector the marine inspector shall examine and test the main and auxiliary steering apparatus to the extent necessary to determine that its condition its satisfactory and that its fit for the service intended. MI observed wasted STBD tiller arm and respective bolts. Additionally, the steering armature was not oriented properly. To be corrected prior to credit DD. iaw 46CFR176.25-35(a.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 12 October 2018
Resolved 25 October 2018
Resolution: STBD tiller armature and associated hardware replaced to the satisfaction of the marine inspector.
02 - Structural Conditions › N/A - No Subsystem › Bulkheads - cracking
Issued 12 September 2018 Resolved
Examine all accessible parts of the exterior and interior of the hull, the watertight bulkheads, and the weather deck. MI observed doubler plate repairs in space immediately aft of fore peak. One on aft bulkhead on the port side and two along weld seams on port hull. Submit repair proposal to MI and repair prior to credit DD.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 12 September 2018
Resolved 11 October 2018
Resolution: Vessel operator appealed this CG-835. Appeal routed through supervisors, appeal granted. Doubler plates throughout vessel and particularly ivo fuel tank to be thoroughly inspected at each exam.
Communications › Radio Communications › VHF Radiotelephone
Issued 29 November 2017 Resolved
MMSI not programmed into vessel's radio. 46CFR184.502
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 30 December 2017
Resolved 30 December 2017
Electrical › Electrical Distribution System (service) › Distribution Panel Bus
Issued 29 November 2017 Resolved
STBD side breaker panel in wheelhouse not labeled properly 46CFR183.220
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 14 December 2017
Resolved 30 December 2017
Communications › Alarms/Indicators › Bilge Alarm
Issued 29 November 2017 Resolved
High water alarm in Lazarette inoperable. 46CFR182.530
Condition: Placed in Improper Service
Action required: 705 - Other - as specified
Due 29 November 2017
Resolved 29 November 2017
Lifesaving › Lifebuoys › Self-igniting Lights
Issued 29 November 2017 Resolved
Water lights on life ring and (3) attached to the lifefloats do not have the correct top fittings for the associated housing it is connected to.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 14 December 2017
Resolved 30 December 2017
Engineering › Bilge Water Management System › Piping
Issued 29 November 2017 Resolved
Fixed metallic bilge piping has flex hose connections in numerous places throught bilge piping system. 46CFR182.40-5(b) Old T
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 14 December 2017
Resolved 30 December 2017
Construction/Loadline › Hull › Weld
Issued 14 September 2016 Resolved
Repair broken welds where indicated by marine inspector IAW 46 CFR 176.610a
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 11 October 2016
Electrical › Electrical Distribution System (service) › Wiring
Issued 9 September 2016 Resolved
Mast wiring not adequately protected from weather. Properly splice and protect new cable in place IAW 46 CFR 183.05-45
Action required: 705 - Other - as specified
Resolved 11 October 2016
Navigation › Collision/Grounding Avoidance › Navigation Lights
Issued 9 September 2016 Resolved
Navigation lights shield no longer properly colored. Restore to matte black IAW Rules of the Road
Action required: 705 - Other - as specified
Resolved 11 October 2016
Fire Fighting › Fire Hoses › Number
Issued 9 September 2016 Resolved
Replace missing fire hose IAW 46 CFR 181.15-10
Action required: 705 - Other - as specified
Resolved 11 October 2016
Fire Fighting › Fire Main › Condition
Issued 9 September 2016 Resolved
Fire main union and flex hose leaking, port side. Repair leak as original and prove proper operation IAW 46 CFR 181.15
Action required: 705 - Other - as specified
Resolved 11 October 2016
Engineering › Diesel Engine (propulsion-reduction gear) › Turbocharger
Issued 9 September 2016 Resolved
Protect engine exhaust where lagging is missing, port and starboard IAW 46 CFR 182.20-15
Action required: 705 - Other - as specified
Resolved 11 October 2016
Fire Fighting › Fire Main › Pressure
Issued 9 September 2016 Resolved
Replace fire pump discharge pressure gauge; currently inoperable IAW 46 CFR 181.10-1(c)
Action required: 705 - Other - as specified
Resolved 11 October 2016
Fire Fighting › Combustible Materials › Ceilings
Issued 9 September 2016 Resolved
Repair or replace engine room boundary insulation where falling IAW 46 CFR 177.405 (a)
Action required: 705 - Other - as specified
Resolved 11 October 2016
Fire Fighting › Remote Fuel Shutoff › General
Issued 9 September 2016 Resolved
Properly mark location and direction of turn for emergency fuel shutoff IAW 46 CFR 185.608
Action required: 705 - Other - as specified
Resolved 11 October 2016
Stability › Watertight Integrity › General
Issued 9 September 2016 Resolved
Leaking engine room and lazarette hatches. Prove proper water tight seal IAW 46 CFR 171.124
Action required: 705 - Other - as specified
Resolved 11 October 2016
Electrical › Lighting (service) › Switch
Issued 4 September 2015 Resolved
Cover cable box light switches in forepeak and generator space to make watertight. 46CFR183.10-20(f)(3) or (k)
Due 18 September 2015
Resolved 8 September 2015
Resolution: Light switches were properly covered and sealed.
Electrical › Electrical Distribution System (service) › Wiring
Issued 4 September 2015 Resolved
Remove dead-end wires in generator space and space above machinery space. 46CFR183.10-20(a)
Due 18 September 2015
Resolved 8 September 2015
Resolution: Dead-end wiring was removed.
Electrical › Electrical Distribution System (service) › Cable
Issued 4 September 2015 Resolved
Remove portable cord plugged into main engine. 46CFR183.10-20(a)(2)
Due 18 September 2015
Resolved 8 September 2015
Resolution: Portable cord was removed.
Fire Fighting › Portable CO2 Fire Extinguisher › Mounting Bracket
Issued 4 September 2015 Resolved
Secure both passenger compartment fire extinguishers. 46CFR181.30-10(b)
Due 18 September 2015
Resolved 8 September 2015
Resolution: Fire extinguishers are properly mounted.
Lifesaving › Hand Flares › Storage
Issued 4 September 2015 Resolved
Stow distress signals in brightly colored, portable watertight container. 46CFR180.68
Due 18 September 2015
Resolved 8 September 2015
Resolution: Distress signals are stowed in orange watertight container.
Lifesaving › Buoyant Apparatus › Lifeline
Issued 4 September 2015 Resolved
2 lifefloat's grab lines must be repaired to the satisfaction of CG Marine Inspector. 46CFR180.137
Action required: 705 - Other - as specified
Due 18 September 2015
Resolved 8 September 2015
Resolution: Grab lines were replaced with new and approved type.
Lifesaving › Lifejacket/PFD (General) › Storage
Issued 4 September 2015 Resolved
Properly label lifejacket stowage areas. 46CFR185.604
Due 18 September 2015
Resolved 8 September 2015
Resolution: Lifejacket stowage areas are labeled using sharpie marker.
Fire Fighting › Fire Hoses › Condition
Issued 12 August 2014 Resolved
Fire hose was worn with several holes in it. Hose was destroyed in the presence of Coast Guard inspectors. New hose will be delivered to the vessel tomorrow- before vessel carries passengers. IAW 46 CFR 181.320
Action required: 705 - Other - as specified
Due 26 August 2014
Resolved 14 August 2014
Resolution: New hose was delivered to the vessel, installed, and tested.
Fire Fighting › Fire Hoses › Condition
Issued 30 July 2012 Resolved
Provide repair or replacement for starboard side fire hose IAW 46CFR181.320.
Condition: Damaged By Earlier Event
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 1 August 2012
Resolution: Provided evidence.
Lifesaving › Lifebuoys › Serviceable
Issued 8 August 2011 Resolved
Repair/replace ring buoys (2) IAW 46CFR180.70
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 11 August 2011
Lifesaving › Lifefloat › Paddle
Issued 8 August 2011 Resolved
Replace broken lifefloat paddles IAW 46CFR180.175
Due 15 August 2011
Resolved 13 August 2011
Lifesaving › Lifefloat › Float-free Link
Issued 8 August 2011 Resolved
Replace weak link on all life floats IAW 46CFR180.137
Due 15 August 2011
Resolved 13 August 2011
Fire Fighting › Fire Hoses › Connections
Issued 8 August 2011 Resolved
Repair/replace fire hose and gate valve for stbd side IAW 46CFR181.320
Due 15 October 2011
Resolved 13 August 2011
Accommodation/Occupational Safety › Medical/First Aid › Medicine Chest
Issued 8 August 2011 Resolved
Replace expired meds in first aid kit IAW 46CFR160.041
Due 15 August 2011
Resolved 13 August 2011
Lifesaving › Lifefloat › Floating Electric Waterlight
Issued 8 August 2011 Resolved
Replace expired life float light battery IAW 46CFR180.200
Due 15 August 2011
Resolved 13 August 2011
Lifesaving › Lifebuoys › Buoyant Lifeline
Issued 8 August 2011 Resolved
Replace corrosive clip on ring buoy line with non-corrosive clip IAW 46CFR180.70
Due 15 August 2011
Resolved 13 August 2011
Electrical › Electrical Distribution System (service) › Non-conducting Deck Covering
Issued 8 August 2011 Resolved
Provide proof of anti-static matting in front of switchboard in engine room IAW 46CFR183.220
Due 15 August 2011
Resolved 7 September 2011
Stability › Watertight Integrity › General
Issued 8 August 2011 Resolved
Provide proof that fwd generator spaces aft bulkhead is watertight IAW 46CFR179.212
Due 15 August 2011
Resolved 7 September 2011
Stability › Watertight Integrity › General
Issued 8 August 2011 Resolved
Repair/replace valve for fwd peak IAW 46CFR179.360
Due 22 August 2011
Resolved 7 September 2011
Electrical › Electrical Distribution System (service) › Wiring
Issued 8 August 2011 Resolved
Provide proof of chafing gear on windlass wiring in fwd peak IAW 46CFR183.220
Due 10 September 2011
Resolved 7 September 2011
Electrical › Electric Supply System (service) › Battery Installation
Issued 8 August 2011 Resolved
Provid proof that all battery connections are made permanent IAW 46CFR183.310
Due 15 August 2011
Resolved 13 August 2011
Electrical › Electrical Distribution System (service) › Circuit Breaker
Issued 8 August 2011 Resolved
Provide proof of proper labeling of breaker box on fwd bulkhead of engine room IAW 46CFR183.330
Due 15 August 2011
Resolved 7 September 2011
Electrical › Electric Supply System (service) › Battery Conductor
Issued 8 August 2011 Resolved
Provide proof that battery swithc is properly mounted IAW 46CFR183.220
Due 15 August 2011
Resolved 7 September 2011
Engineering › Fuel Oil Service System › Valve, Control
Issued 27 August 2008 Resolved
MAKE PERMANENT REPAIRS TO REMOTE FUEL SHUTOFF VLV AT NEXT DRYDOCK.
Action required: 705 - Other - as specified
Resolved 16 October 2008
Resolution: Remote fuel shutoff assembly was repaired while in drydock.
Construction/Loadline › Penetrations › Gasket
Issued 27 August 2008 Resolved
REPLACE GASKETS IN ALL WATERTIGHT HATCHES.
Due 3 September 2008
Resolved 16 October 2008
Resolution: New gaskets were installed while in drydock.
Engineering › Bilge Water Management System › Interface Detector
Issued 5 October 2006 Resolved
REPAIR BILGE ALARM IWO FWD GENERATOR ROOM.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 12 October 2006
Resolved 2 January 2007
Engineering › Sea-water System (primary cooling) › Pump
Issued 5 October 2006 Resolved
MOUNT WASH DOWN PUMP IWO ENGINE ROOM.
Condition: Design Flaw
Action required: 705 - Other - as specified
Due 19 October 2006
Resolved 2 January 2007
Documentation › Certificates/Documents › FCC SSL
Issued 22 August 2006 Resolved
Provide a FCC Safety Radio Certificate. Certificate expired at the end of May.
Condition: Improper/Lack of Maintenance
Due 29 August 2006
Resolved 28 August 2006
Resolution: RECEIVED A NEW CERTIFICATE, SAT
Documentation › Certificates/Documents › FCC SSL
Issued 22 August 2006 Resolved
Provide a bridge-to-bridge radio certificate. POC stated that they never had one.
Condition: Improper/Lack of Maintenance
Due 29 August 2006
Resolved 28 August 2006
Resolution: REVIEWED CERTIFICATE, SAT
Engineering › Lubricating Oil Service System › Hose
Issued 22 August 2006 Resolved
Repair small hydraulic leaks in hydraulic line for anchor windless IWA FWD void.
Condition: Improper/Lack of Maintenance
Due 29 August 2006
Resolved 5 September 2006
Resolution: REPLACED LINES.
Construction/Loadline › Penetrations › Gasket
Issued 22 August 2006 Resolved
Seal all BLKHD penetrations throughout vessel as discussed. They had wires that were loose going through BLKHD's.
Condition: Improper/Lack of Maintenance
Due 29 August 2006
Resolved 5 September 2006
Resolution: ALL SEALED.
Accommodation/Occupational Safety › Occupational Safety › Guards for Exposed Hazards
Issued 22 August 2006 Resolved
Provide a safety shield for the FWD generator pulley assembly and one over the shaft coupler for the FWD bilge pump.
Condition: Improper/Lack of Maintenance
Due 29 August 2006
Resolved 5 September 2006
Resolution: INSTALLED NEW SHIELD.
Engineering › Bilge Water Management System › Manifold
Issued 22 August 2006 Resolved
Label valves/system on the FWD bilge manifold. Labels have fadded off.
Condition: Improper/Lack of Maintenance
Due 29 August 2006
Resolved 5 September 2006
Resolution: ALL RE-LABELED WITH A DRAWING.
Engineering › Diesel Engine (propulsion-reduction gear) › Block
Issued 22 August 2006 Resolved
Prior to the carriage of passengers, provide a third party report on the conditions of BMDE's. POC stated that they were having the mechanic come down and look at the STBD engine for a possible blown head gasket. The PORT engine had oil all over the sides and on the OVHD.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 22 August 2006
Resolved 28 August 2006
Resolution: MACHANIC CHANGED THE HEAD ON THE STBD ENGINE AND RECCOMENDED THAT THEY REPLACE SEVERAL GASKETS ON THE ENGINES. CREW WAS IN THE PROCESS OF THIS, WHICH WILL TAKE TIME. CLEARED DEFICIENCY BECAUSE CREW IS AWARE OF LEAKS.
Accommodation/Occupational Safety › Occupational Safety › Rubbish/Waste Materials
Issued 22 August 2006 Resolved
Prior to the carriage of passengers, clean all oil from engines, engine room OVHD and bilge.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 22 August 2006
Resolved 28 August 2006
Resolution: CREW HAD CLEANED AND WERE STILL CLEANING OIL UP.
Engineering › Steering Gear System › Rudder
Issued 22 August 2006 Resolved
Provide rudder stops and replace all wasted metal on steering ram system prior to up-coming ship yard period.
Condition: Improper/Lack of Maintenance
Due 20 September 2006
Resolved 5 September 2006
Resolution: NEW STOPS WERE FABRICATED AND INSTALLED.
Lifesaving › Lifejacket/PFD (General) › Storage
Issued 22 August 2006 Resolved
Properly label life jacket stowage boxes. (ex: 15 ADULT LIFE PRESERVERS) They just had 15 AD or 15 CH.
Condition: Improper/Lack of Maintenance
Due 29 August 2006
Resolved 5 September 2006
Resolution: ALL LABELED
Lifesaving › Buoyant Apparatus › Approval
Issued 22 August 2006 Resolved
Prior to the carriage of passengers, provide on ring life buoy. One buoy was wasted.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 22 August 2006
Resolved 28 August 2006
Resolution: NEW RING BUOY MARKED AND ON VESSEL
Engineering › Fuel Oil Service System › Valve
Issued 22 August 2006 Resolved
Label emergency fuel oil valve.
Condition: Improper/Lack of Maintenance
Due 29 August 2006
Resolved 28 August 2006
Resolution: LABELED
Operations/Management › Drug and Alcohol Testing › Employee Coverage
Issued 22 August 2006 Resolved
Complete all DAPI requirements from audit form. POC had one crew member training onboard that was never pre-tested prior to hire.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 29 August 2006
Resolved 5 September 2006
Resolution: CORRECTED.
Lifesaving › Buoyant Apparatus › Serviceable
Issued 23 May 2005 Resolved
REPAIR OR REPLACE 25 PERSON LIFEFLOAT DROP NET. VESSEL RESTRICTED TO 50 TOTAL PERSONS ON OCEANS ROUTE AND 100 TOTAL PERSONS ON LIMITED COASTWISE ROUTE.
Due 23 June 2005
Resolved 17 June 2005
Resolution: FAX / PHOTOGRAPHIC DOCUMENTATION.
Documentation › Manuals/Policy Documentation › Emergency Instructions
Issued 23 May 2005 Resolved
RE-WRITE EMERGENCY PROCEDURES UNIQUE TO VESSEL OPERATIONS.
Due 23 June 2005
Resolved 17 June 2005
Resolution: FAX DOCUMENTATION.
Engineering › Fuel Oil Storage/Transfer System › Vent Pipe
Issued 23 May 2005 Resolved
REPLACE FLAME SCREEN ON STBD FUEL VENT.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 17 June 2005
Resolution: FAX DOCUMENTATION.
Operations/Management › Drug and Alcohol Testing › EAP Training Requirements
Issued 23 May 2005 Resolved
POST EAP PHONE #.
Due 23 June 2005
Resolved 17 June 2005
Resolution: FAX DOCUMENTATION.
Electrical › Electrical Distribution System (service) › Outlet Box
Issued 23 May 2005 Resolved
REPAIR OUTLET BOXES IN GALLEY IN WAY OF COFFEE MAKER.
Due 23 June 2005
Resolved 17 June 2005
Resolution: FAX / PHOTOGRAPHIC DOCUMENTATION.
Engineering › Bilge Water Management System › Piping
Issued 20 September 2004 Resolved
PROVIDE DETAILED PIPING DIAGRAM AND BILGE OPERATION INSTRUCTIONS IN PILOT HOUSE, ENGINE ROOM AND FUEL TANK SPACE.
Due 15 November 2004
Resolved 22 December 2004
Resolution: FAX AND PHONECON.
Documentation › Certificates/Documents › Certificate of Inspection
Issued 20 September 2004 Resolved
Upon review of activity 2183446, noted owner/operator failed to make vesel available for annual inspection w/in 3 months before or after each anniversary date of issuance of the COI. Late annual inspection conducted on activity2168747
Due 20 September 2004
Resolved 20 September 2004
Resolution: Inspector attended vessel to conduct annual inspection.
Lifesaving › Buoyant Apparatus › Floating Electric Waterlight
Issued 24 August 2004 Resolved
REPLACE BATTERY IN CENTER LIFEFLOAT WATERLIGHT PRIOR TO CARRIAGE OF PASSENGERS.
Due 31 August 2004
Resolved 24 August 2004
Resolution: FAX.
Engineering › Freshwater Generation System › Piping
Issued 24 August 2004 Resolved
REPLACE HOSE CLAMPS ON FORWARD GENSET EXHAUST PRIOR TO CARRIAGE OF PASSENGERS..
Due 31 August 2004
Resolved 24 August 2004
Resolution: FAX.
Engineering › Bilge Water Management System › Valve
Issued 24 August 2004 Resolved
LOSEN FORWARD BILGE SUCTION REACH ROD AND INSTALL WRENCH TO OPEN VALVE PRIOR TO CARRIAGE OF PASSENGERS.
Due 31 August 2004
Resolved 24 August 2004
Resolution: FAX.
Navigation › Piloting/Steering › US Coast Pilot
Issued 24 August 2004 Resolved
UPDATE COAST PILOT AND LIGHT LIST.
Due 1 September 2004
Resolved 24 August 2004
Resolution: PROVIDED WEB SITE.
Operations/Management › Drills/Instruction
Issued 3 September 2003 Resolved
Prior to the carriage of passengers, conduct a New-To-Zone inspection with MSO Puerto Rico.
Due 3 September 2003
Resolved 3 September 2003
Lifesaving › Lifejacket/PFD (Type I) › Retroreflective Material
Issued 26 August 2003 Resolved
REPLACE RETRO ON 06 ADULT TYPE I LIFEJACKETS PRIOR TO CARRIAGE OF PASSENGERS.
Due 6 September 2003
Resolved 26 August 2003
Resolution: FAX DOCUMENTATION - WITNESSED RETRO.
Lifesaving › Buoyant Apparatus
Issued 26 August 2003 Resolved
REPAIR MIDDLE LIFEFLOAT HAND ROPE BRACKET. LEGACY COMPONENT DESC: Bracket
Due 6 September 2003
Resolved 26 August 2003
Resolution: FAX DOCUMENTATION.
Engineering › Steering Gear System › Hydraulic Hose
Issued 26 August 2003 Resolved
REPAIR INBOARD HYDRAULIC LINE FITTING ON STEERING SYSTEM.
Due 6 September 2003
Resolved 26 August 2003
Resolution: FAX DOCUMENTATION.
Engineering › Steering Gear System
Issued 26 August 2003 Resolved
REPAIR HYDRAULIC RAM OUTBOARD FITTING. LEGACY COMPONENT DESC: Ram Seal
Due 6 September 2003
Resolved 16 September 2003
Engineering › Bilge Water Management System
Issued 26 August 2003 Resolved
INSTALL GUARD ON BILGE PUMP PULLEY. LEGACY COMPONENT DESC: Pump
Due 6 September 2003
Resolved 16 September 2003
Deck/Cargo › Holds/Tanks
Issued 26 August 2003 Resolved
LABEL EMERGENCY ESCAPE HATCHES IN ENGINE ROOM. LEGACY COMPONENT DESC: Hatch Cover
Due 6 September 2003
Resolved 26 August 2003
Resolution: FAX DOCUMENTATION.
Engineering › Fuel Oil Storage/Transfer System
Issued 26 August 2003 Resolved
REPAIR EMERGENCY FUEL STOP PRIOR TO CARRIAGE OF PASSENGERS. LEGACY COMPONENT DESC: Valve
Due 6 September 2003
Resolved 26 August 2003
Resolution: FAX DOCUMENTATION.
Engineering › Bilge Water Management System
Issued 26 August 2003 Resolved
REPAIR FWD BILGE REACH ROD PRIOR TO CARRIAGE OF PASSENGERS. LEGACY COMPONENT DESC: Valve
Due 6 September 2003
Resolved 26 August 2003
Resolution: CORRECTED ON SPOT.
Lifesaving › Buoyant Apparatus
Issued 3 September 2002 Resolved
PROPERLY INSTALL SEA PAINTER/WEAK LINK/TEATHER LINES ON LIFEFLOATS PRIOR TO CARRIAGE OF PASSENGERS.
Condition: Improper Installation
Due 10 September 2002
Resolved 5 December 2002
Resolution: SAT
Lifesaving › Buoyant Apparatus
Issued 3 September 2002 Resolved
REPLACE HAND LINE ON UPPER LIFEFLOAT PRIOR TO CARRIAGE OF PASSENGERS.
Condition: Improper/Lack of Maintenance
Due 10 September 2002
Resolved 5 December 2002
Resolution: SAT
Electrical › Electrical Distribution System (service)
Issued 3 September 2002 Resolved
REPLACE STANDARD HOUSEHOLD WIRING UNDER SINK OUTLET AND EXHAUST VENT. LEGACY COMPONENT DESC: Wiring
Condition: Improper Installation
Due 3 October 2002
Resolved 5 December 2002
Resolution: SAT
Lifesaving › Lifejacket/PFD (Type IV)
Issued 3 September 2002 Resolved
REPLACE 1 LIFERING PRIOR TO CARRIAGE OF PASSENGERS. LEGACY COMPONENT DESC: Condition
Condition: Improper/Lack of Maintenance
Due 10 September 2002
Resolved 5 December 2002
Resolution: SAT
Electrical › Lighting (service)
Issued 3 September 2002 Resolved
INSTALL DIFFUSERS ON OVERHEAD LIGHTING IN BOTH HEADS. LEGACY COMPONENT DESC: Neutral Bus
Condition: Improper/Lack of Maintenance
Due 10 September 2002
Resolved 5 December 2002
Resolution: SAT
Lifesaving
Issued 4 June 2001 Resolved
PRIOR TO CARRIAGE OF PASENGERS, REPLACE 24" RING BOUY.
Condition: Unknown
Due 4 June 2001
Resolved 4 June 2001
Unknown
Issued 4 June 2001 Resolved
UPDATE COPIES OF LIGHT LIST, COAST PILOT, NAVIGATION RULES, AND TIDES & CURRENTS.
Condition: Unknown
Due 4 June 2001
Resolved 4 June 2001
Lifesaving
Issued 4 June 2001 Resolved
PRIOR TO CARRIAGE OF PASSENGERS, RENEW 6 RED HAND HELD FLARES.
Condition: Unknown
Due 4 June 2001
Resolved 4 June 2001
Construction/Loadline
Issued 4 June 2001 Resolved
REPAIR SLICE IN AFT BILGE SUCTION LINE.
Condition: Unknown
Due 4 June 2001
Resolved 4 June 2001
Lifesaving
Issued 22 May 2000 Resolved
INSTALL AID TO ASSIST IN RECOVERY OF HELPLESS PERSON FROM WATER AND DEMONSTRATE MAN OVERBOARD PROCEDURES.
Condition: Unknown
Due 22 May 2000
Resolved 22 May 2000
Lifesaving
Issued 22 May 2000 Resolved
REMOVE SILICONE FROM EMERGENCY ESCAPE HATCHES AND PROPERLY STENCIL "EMERGENCY ESCAPE, KEEP CLEAR".
Condition: Unknown
Due 22 May 2000
Resolved 22 May 2000
Construction/Loadline
Issued 22 May 2000 Resolved
REPAIR FWD BILGE SUCTION REACH ROD AND PROPERLY STENCIL WITH ARROW IN DIRECTION OF CLOSURE.
Condition: Unknown
Due 22 May 2000
Resolved 22 May 2000
Engineering
Issued 22 May 2000 Resolved
REPAIR FLAME SCREEN IN FUEL VENT.
Condition: Unknown
Due 24 May 2000
Resolved 24 May 2000
Engineering
Issued 22 May 2000 Resolved
REPAIR PORT MAIN JACKET WATER TEMPERATURE GAUGE.
Condition: Unknown
Due 22 May 2000
Resolved 22 May 2000
Lifesaving
Issued 17 May 1999 Resolved
POST PFD DONNING INSTRUCTIONS FOR ALL TYPES OF PFD'S ON BOARD._x001C_ _x001C_ _x001C_ _x001C_
Condition: Unknown
Due 17 May 1999
Resolved 17 May 1999
Navigation
Issued 17 May 1999 Resolved
PROVIDE CURRENT COPIES OF NAVIGATION RULES, CG LIGHT LIST, COAST PILOT, TIDE/CURRENT TABLES AND CORRECTED CHARTS._x001C_ _x001C_ _x001C_
Condition: Unknown
Due 17 May 1999
Resolved 17 May 1999
Lifesaving
Issued 17 May 1999 Resolved
REPAINT/RELABEL ALL LIFEFLOATS._x001C_ _x001C_ _x001C_ _x001C_
Condition: Unknown
Due 17 May 1999
Resolved 17 May 1999
Engineering
Issued 17 May 1999 Resolved
DOUBLE CLAMP ALL RAW WATER HOSES ON FWD. GENERATOR._x001C_ _x001C_ _x001C_ _x001C_
Condition: Unknown
Due 17 May 1999
Resolved 17 May 1999
Electrical
Issued 17 May 1999 Resolved
INSTALL COVER ON LIGHT FIXTURE AT ENGINEROOM ENTRANCE._x001C_ _x001C_ _x001C_ _x001C_
Condition: Unknown
Due 17 May 1999
Resolved 17 May 1999
Construction/Loadline
Issued 9 April 1997 Resolved
V AND WELD CRACKED WELD IN #2 COMPT. PORTSIDE CHINE AT FWD BULKHEAD AS MARKED. NO PASSENGERS FOR HIRE UNTIL CLEARED.
Condition: Unknown
Due 10 April 1997
Resolved 12 May 1997
Electrical
Issued 18 November 1996 Resolved
INSTALL A MAIN DISCONNECT SWITCH FOR THE STARTING BATTERIES CONNECTED TO THE DIESEL GENERATORS.
Condition: Unknown
Due 13 December 1996
Resolved 10 April 1997
Construction/Loadline
Issued 18 November 1996 Resolved
PROVIDE A STUFFING TUBE FOR THE CONTROL WIRING FOR THE FWB DECK CAPSTAIN WHERE IT PENETRATES THE PORT SIDE OF THE # 3 BHD.
Condition: Unknown
Due 13 December 1996
Resolved 10 April 1997
Engineering
Issued 18 November 1996 Resolved
INSTALL LAGGING ON FWD DIESEL GENERATOR'S EXHAUST PIPE.
Condition: Unknown
Due 13 December 1996
Resolved 10 April 1997
Fire Fighting
Issued 18 November 1996 Resolved
PROVIDE 2 ADDITIONAL BII FIRE EXTINGUISHERS FOR THE DIESEL GENERATOR SPACE.
Condition: Unknown
Due 13 December 1996
Resolved 10 April 1997
Construction/Loadline
Issued 25 January 1995 Resolved
IN ENG RM U/W CRACKED WELDS IN FRAMES #2 & #4, PORT SIDE, IWO MAIN DECK.
Condition: Unknown
Due 14 February 1995
Resolved 14 February 1995
Construction/Loadline
Issued 25 January 1995 Resolved
IN ENG RM V/W CRACKED WELD ON FRAME #2 IWO #2 SSL.
Condition: Unknown
Due 14 February 1995
Resolved 14 February 1995
Construction/Loadline
Issued 25 January 1995 Resolved
IN LAZARETTE V/W AROUND FRESH WATER INTAKE & MAIN DECK._x001C_ _x001C_
Condition: Unknown
Due 14 February 1995
Resolved 14 February 1995
Construction/Loadline
Issued 25 January 1995 Resolved
IN LAZARETTE V/W CRACKED WELD ON #4 DECK LONG & #2 DECK TRANSV.
Condition: Unknown
Due 14 February 1995
Resolved 14 February 1995
Construction/Loadline
Issued 25 January 1995 Resolved
IN LAZERETTE V/W CRACKED WELD IN #2 DECK TRANS, IWO SSL #2 (STBD).
Condition: Unknown
Due 14 February 1995
Resolved 14 February 1995
Construction/Loadline
Issued 25 January 1995 Resolved
IN LAZARETTE V/W CRACKED WELD AFT OF #2 FRAME IN STBD SIDE.
Condition: Unknown
Due 14 February 1995
Resolved 14 February 1995
Construction/Loadline
Issued 25 January 1995 Resolved
V/W CRACKED WELD IN BAY 3 AT #7SSL IN FOREPEAK.
Condition: Unknown
Due 14 February 1995
Resolved 14 February 1995
Construction/Loadline
Issued 25 January 1995 Resolved
V/W CRACKED WELD IN BAY 3 AT #7 SSL IWO FRAME #3 IN FORPEAK.
Condition: Unknown
Due 14 February 1995
Resolved 14 February 1995
Construction/Loadline
Issued 13 April 1994 Resolved
IN 3RD COMPARTMENT STBD SIDE VEE & WELD CRACKED WELD IWO #5 FRAME AND DEEP WEB LONG.
Condition: Unknown
Due 13 April 1994
Resolved 13 April 1994
Construction/Loadline
Issued 13 April 1994 Resolved
IN 3RD COMPARTMENT PORTSIDE VEE & WELD CRACKED WELDS IWO #3, 4, & 6 FRAME_x001C_ AND DEEP WEB LONG.
Condition: Unknown
Due 13 April 1994
Resolved 13 April 1994
Construction/Loadline
Issued 26 October 1992 Resolved
MAKE VESSEL AVAILABLE FOR CREDIT DRYDOCK EXAM NO LATER THAN 31MAR93.
Condition: Unknown
Due 26 October 1992
Resolved 26 October 1992
Construction/Loadline
Issued 4 April 1991 Resolved
REPAIR FRACTURES #2 COMPT (A) TOP OF STANTION #2 ON STB SIDE (B) FWD OF PORT BOTTOM LONGITUDINAL (3) 3 COMPT, BOTTOMING OF STANTION PORT SIDE AND AT FRAME NEAR BOTTOM OF STANTION
Condition: Unknown
Due 31 July 1991
Resolved 31 July 1991
Navigation
Issued 27 March 1989 Resolved
PROVIDE CURRENT ISSUES OF SAILING DIRECTIONS, COAST PILOT, LIGHT LIST (USCG) AND NAV RULES.
Condition: Unknown
Due 27 March 1989
Resolved 27 March 1989
Navigation
Issued 27 March 1989 Resolved
PROVIDE PROPER FIXTURES FOR ALL NAVIGATION LIGHTS I/A/W NAVRULES/CO/REGS.
Condition: Unknown
Due 27 March 1989
Resolved 27 March 1989
Fire Fighting
Issued 27 March 1989 Resolved
PROVIDE DISCHARGE SIDE PRESSURE GAUGE FOR ELECTRIC FIRE PUMP: I/A/N
Condition: Unknown
Due 27 March 1989
Resolved 27 March 1989
Electrical
Issued 27 March 1989 Resolved
WHERE BROKEN PROVIDE OPERATIONAL TEST OF LIGHT SWITCH FOR LAZARETTE.
Condition: Unknown
Due 27 March 1989
Resolved 27 March 1989
Electrical
Issued 24 March 1988 Resolved
MAKE NECESSARY CHANGES TO VESSEL'S DC WIRING TO PROVIDE OVER-CURRENT PROTECTION FOR THE WIRING BETWEEN THE ENGINE ROOM AND THE BRIDGE.
Condition: Unknown
Due 24 March 1988
Resolved 24 March 1988
Construction/Loadline
Issued 24 March 1988 Resolved
REPAIR FRACTURES TO PORT & STBD RUDDER POST TUBE REINFORCING GUSSETS.
Condition: Unknown
Due 24 March 1988
Resolved 24 March 1988
Construction/Loadline
Issued 24 March 1988 Resolved
REPAIR FRACTURE PORT SIDE CHINE AFT OF COLLISION BHD.
Condition: Unknown
Due 24 March 1988
Resolved 24 March 1988
Construction/Loadline
Issued 24 March 1988 Resolved
REPAIR FRACTURES TO BOTTOM FRAMING IN #3 & #5 COMPARTMENTS AS MARKED.
Condition: Unknown
Due 24 March 1988
Resolved 24 March 1988

Casualty record · 2

29 January 2010Routine · role: Involved in a Marine Casualty · activity 3680474
26 August 2017Routine · role: Involved in a Marine Casualty · serious marine incident, as classified · 1 injured · activity 6255993
Each line is an incident investigation the Coast Guard recorded with this hull among the vessels involved, with the date and the classification the Coast Guard gave it, and the bridge, lock or dam the investigation names where it names one. Involvement is not fault. The investigation narrative is not published. Source: IIR, through 2026.

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.