Inspection history · 21
14 April 2026
Internal Structural Exam · Examination of Repairs · Drydock Exam · Administrative Inspection · Vessel Attendance
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 8311404
18 November 2025
Annual Inspection · Internal Structural Exam · Administrative Inspection
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 8270164
19 March 2025
Administrative Inspection
Administrative · Sector Delaware Bay · USCG East District (CGD-E) · Activity 8096253
27 December 2024
Administrative Inspection
Administrative · Sector Delaware Bay · USCG East District (CGD-E) · Activity 8051145
19 November 2024
Annual Inspection · Internal Structural Exam
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 8036221
18 May 2024
Damage Survey
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 7915496
24 April 2024
Drydock Exam · Internal Structural Exam
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 7900962
16 November 2023
Annual Inspection
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 7827987
16 November 2022
Deficiency Check · Annual Inspection
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 7590819
20 April 2022
Drydock Exam · Internal Structural Exam
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 7434313
24 November 2021
Administrative Inspection
Administrative · Sector Delaware Bay · USCG East District (CGD-E) · Activity 7357068
13 October 2021
COI Inspection
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 7331654
18 November 2020
Annual Inspection · Deficiency Check
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 7095983
23 April 2020
Internal Structural Exam · Drydock Exam
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 6942721
19 November 2019
Annual Inspection
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 6858704
14 November 2018
Annual Inspection · DAPI Audit · Administrative Inspection
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 6578281
9 August 2018
Administrative Inspection
Administrative · Navigation Center · Activity 6505738
20 April 2018
Internal Structural Exam · Administrative Inspection · Hull Examination
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 6395890
13 November 2017
Annual Inspection
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 6306176
14 November 2016
COI Inspection · DAPI Audit
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 6040831
24 April 2016
Internal Structural Exam · Hull Examination · Deadweight Survey
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 5879904
02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 18 November 2025
Resolved
Each vessel must meet the applicable requirements in Subchapter S of this chapter. Observed a hole in the port side collision bulkhead. Provide a temporary repair to the hole in the watertight collision bulkhead to the satisfaction of the attending marine inspector. Permanent repair to be completed in dry dock.
46 CFR 177.13-1 Old T
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 20 November 2025
Resolution: Temporary repairs made. See documents
02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 18 November 2025
Resolved
Each vessel must meet the applicable requirements in Subchapter S of this chapter. Open cable run and two drill holes found on bulkhead separating engine and lazarette, also another open cable run on bulkhead 11 in the same compartment. Provide repairs to maintain watertight integrity on bulkheads to the satisfaction of attending marine inspector.
46 CFR 177.13-1 Old T
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 20 November 2025
Resolution: Made temporary repairs. See documents
07 - Fire Safety › N/A - No Subsystem › Fire detection and alarm system
Issued 18 November 2025
Resolved
Vessels described by 46 CFR 175.110(c) must have an interconnected fire detection system in compliance with § 181.450 installed in all enclosed areas where passengers and crew have routine access, including accommodation spaces and machinery spaces. Vessel does not have interconnected fire detection in the machinery spaces. Provide interconnected fire detectors in port and starboard side engine spaces to the satisfaction of attending marine inspector. Vessel is restricted to Limited Coastwise until rectified.
46 CFR 181.405
Action required: 705 - Other - as specified
Resolved 24 November 2025
Resolution: new interconnected detectors placed in both engine rooms.
09 - Working and Living Conditions › 092 - Working Conditions › Other (accident prevention)
Issued 18 November 2025
Resolved
Shall examine all accessible parts of the vessels, hull, machinery, and equipment to be assured that they are in satisfactory condition. Exhaust water line is secured overhead with the use of zip ties. Provide a suitable arrangement that is resistant to heat and wear to the satisfaction of attending marine inspector.
46 CFR 176.10-5(b)
Old T
Action required: 16 - Rectify deficiencies w/in 14 days
Due 2 December 2025
Resolved 24 November 2025
Resolution: Provided new metal strap to secure line.
01 - Certificates & Documentation › 013 - Documents › Log-books/compulsory entries
Issued 18 November 2025
Resolved
The owner of a vessel subject to inspection under section 3301 shall ensure that such vessel is equipped with a vessel master key control system, manual or electronic, which provides controlled access to all copies of the vessel’s master key of which access shall only be available to the individuals described in paragraph (2). Vessel does not have a master key control log. Provide log for master key control system.
46 U.S.C. § 3106
Action required: 16 - Rectify deficiencies w/in 14 days
Due 2 December 2025
Resolved 24 November 2025
Resolution: Provided log book.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 18 November 2025
Resolved
Each lifeline on a ring life buoy must: Have a breaking strength of at least 5 kilonewtons (1,124 pounds). Life buoy line was found rotted. Provide new lifeline for life buoy.
46 CFR 180.70(c)(5)
Action required: 16 - Rectify deficiencies w/in 14 days
Due 2 December 2025
Resolved 25 November 2025
Resolution: Replaced life line.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 18 November 2025
Resolved
Placards containing instructions for the donning and use of the life jackets aboard the vessel must be posted in conspicuous places that are regularly accessible and visible to the crew and passengers. Vessel needs additional placard for the newer lifejackets onboard.
46 CFR 185.516(a)
Action required: 16 - Rectify deficiencies w/in 14 days
Due 2 December 2025
Resolved 24 November 2025
Resolution: New placard posted.
10 - Safety of Navigation › N/A - No Subsystem › Charts
Issued 18 November 2025
Resolved
As appropriate for the intended voyage, a vessel must carry adequate and up-to-date: (1) Charts of large enough scale to make safe navigation possible; (2) U.S. Coast Pilot or similar publication; (3) Coast Guard Light List; (4) Tide tables; and (5) Current tables. Pubs are outdated.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 2 December 2025
Resolved 24 November 2025
Resolution: Provided updated pubs.
09 - Working and Living Conditions › 092 - Working Conditions › Other (accident prevention)
Issued 18 November 2025
Resolved
Vessel control systems and other miscellaneous systems and equipment required by this part must be suitable for the purposes intended. Port side accommodation space heater has wasted guard. Replace guard on space heater.
46 CFR 184.100(a)
Action required: 16 - Rectify deficiencies w/in 14 days
Due 2 December 2025
Resolved 20 November 2025
Resolution: Made repair. See documents.
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 18 November 2025
Resolved
All electrical installations shall be to the satisfaction of the Officer in Charge, Marine Inspection. Exposed wires found on accommodation space overhead above port and starboard weathertight doors and starboard, forward overhead.
46 CFR 183.01-15 OLD T
Action required: 16 - Rectify deficiencies w/in 14 days
Due 2 December 2025
Resolved 24 November 2025
Resolution: Exposed wiring secured to new speakers.
08 - Alarms › N/A - No Subsystem › Other (alarms)
Issued 18 November 2025
Resolved
Gauges to indicate engine cooling water discharge temperature and lubricating oil pressure shall be provided for all propulsion engines and located so as to be in view of the operator. Vessels gauge display for port engine we intermittently operable. Rectify gauges to the satisfaction of attending marine inspector.
46 CFR 182.20-5(b)
Old T
Action required: 16 - Rectify deficiencies w/in 14 days
Due 2 December 2025
Resolved 20 November 2025
Resolution: Replaced guage at helm. see documents
02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 18 November 2025
Resolved
Shall examine all accessible parts of the vessels, hull, machinery, and equipment to be assured that they are in satisfactory condition. Leaks were found on the saltwater pipes in both port and starboard side machinery compartments further adding to the corrosion of the deck in both spaces. Secure leaks in both areas to the satisfaction of attending marine inspector.
46 CFR 176.10-5(b)
Old T
Action required: 50 - Rectify deficiencies w/in 30 days
Due 18 December 2025
Resolved 24 November 2025
Resolution: New fitting installed on port side. Leak secured on existing pipe on starboard side.
01 - Certificates & Documentation › 011 - Ships Certificates › Cargo Ship Safety Radio (including exemption)
Issued 18 November 2025
Resolved
Each vessel must carry a certificate with a valid endorsement while subject to the Bridge-to-Bridge Act. Vessel did not have Bridge to Bridge Act Certificate. Provide valid certificate.
47 CFR 80.1005
Action required: 50 - Rectify deficiencies w/in 30 days
Due 18 December 2025
Resolved 20 November 2025
Resolution: Provided certificate. See documents
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 18 November 2025
Resolved
Each survival craft must be: Stowed so that when the vessel sinks the survival craft floats free and, if inflatable, inflates automatically. Hydrostatic releases on IBAs incorrectly rigged. Corrected by crew on the spot.
46 CFR 180.130(a)(2)
Action required: 10 - Deficiency Rectified
Resolved 18 November 2025
Resolution: Corrected on the spot
03 - Water/Weathertight Conditions › N/A - No Subsystem › Other (load lines)
Issued 19 November 2024
Resolved
Penetrations and openings in watertight bulkheads must have a means to make them watertight. MI observed several holes where previous cables were poking through bulkhead to another compartment. The machinery space on starboard side was observed to have cables going through forward bulkhead. Operator/Owner is to fill holes and ensure bulkhead is watertight.
Condition: Improper Installation
Action required: 10 - Deficiency Rectified
Due 10 December 2024
Resolved 21 November 2024
Resolution: Operator corrected penetrations by plugging and supplied photographs for the approval of MI.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 19 November 2024
Resolved
Wiring joints and splices shall be mechanically secure and made in junction boxes. MI observed loud hailer electrical wires were spliced and exposed to the outdoor elements. Operator/Owner shall protect and secure the wires according to regulation.
Condition: Improper Installation
Action required: 10 - Deficiency Rectified
Due 10 December 2024
Resolved 21 November 2024
Resolution: Operator put splicing in junction box to proctect from elements, supplied photographs for approval by MI.
02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 19 November 2024
Resolved
Discharge pipe that penetrates the hull and at least 6 inches above the deepest load waterline must have a means to prevent water from entering the vessels is the pipe fractures or otherwise fails. MI observed a pipe that was not closed (capped) located in the forward machinery compartment. The Operator/Owner shall seal or cap the pipe to reduce the risk of pipe failure and prevent potential water leakage into the space.
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Due 10 December 2024
Resolved 21 November 2024
Resolution: Operator capped pipe to the approval of MI.
02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 19 November 2024
Resolved
Internal combustion engine exhaust, and similar sources
of ignition shall be kept clear of and suitably insulated from any other combustible matter. MI observed the dry-exhaust from the generator in starboard and port lazarette space was not insulated or protected from other potential hazards. Operator shall insulate the dry-exhaust pipe for the generator in starboard and port lazarette space.
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 26 December 2024
Resolved 17 March 2025
Resolution: Appeal was accepted by OCMI for vessel meeting requirements of old T. Approval letter was sent to Owner and Nav Arch.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Machinery space openings
Issued 16 November 2022
Resolved
Bulkhead penetration fwd/stbd bulkhead of engine room. Ensure bulkhead is watertight.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 17 December 2022
Resolved 17 November 2022
Resolution: O/O installed threaded plug in bulked penetration.
07 - Fire Safety › N/A - No Subsystem › Fire pumps and its pipes
Issued 16 November 2022
Resolved
Fire pump found excessively leaking
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 16 December 2022
Resolved 17 November 2022
Resolution: O/o provided evidence of the repair to the fire pump
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 10 November 2021
Resolved
All wiring and cables shall be suitable for marine service and for the particular installation used. Cap or remove hanging wiring on STBD side of engine room. 46CFR 183.10-20
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 8 December 2021
Resolved 24 November 2021
Resolution: Owner removed hanging wire from engine room.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 10 November 2021
Resolved
All electrical installations shall be to the satisfaction of the Officer Charge, Marine Inspections. Open up generator and clean windings.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 8 December 2021
Resolved 24 November 2021
Resolution: Owner cleaned generator windings and provided pictures.
09 - Working and Living Conditions › 092 - Working Conditions › Pipes, wires (insulation)
Issued 10 November 2021
Resolved
When the flexible section is nonconductor of electricity, the metallic sections of the filling pipe separated thereby shall be joined by a conductor for protection against static spark when filling. Fuel fill pipe grounding was disconnected.46 CFR 182.15-30(d)
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 8 December 2021
Resolved 7 December 2021
Resolution: O/O provided pictures of propely bonded fuel fill.
04 - Emergency Systems › N/A - No Subsystem › Emergency, lighting, batteries and switches
Issued 10 November 2021
Resolved
Batteries shall be located as high above the bilge as practicable and secured against shifting with motion of the boat. Batteries were not properly secured. Put nonconductive material between batteries to prevent movement. 46 CFR 183.05-20(b)
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 8 December 2021
Resolved 24 November 2021
Resolution: Owner provided pictures of wood slat between batteries to prevent from shifting.
11 - Life Saving Appliances › N/A - No Subsystem › Maintenance of Life Saving Appliances
Issued 10 November 2021
Resolved
Each life ring buoy on a vessel must be approved in accordance with subchapter Q of this chapter. Life ring on upper deck STBD side was missing plug.46 CFR 180.70(b)(1)
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 8 December 2021
Resolved 24 November 2021
Resolution: Owner replaced life ring and provided picture.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 10 November 2021
Resolved
That part of the exhaust system between the point of cooling water injection and the engine manifold shall be water jacketed or effectively insulated. Exhaust lagging on port side engine needs to be tightened up.46 CFR 182.15-15(b)(3)
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 8 December 2021
Resolved 24 November 2021
Resolution: Owner sent picture of tightened lagging on exhaust.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Doors
Issued 10 November 2021
Resolved
Each hatch exposed to the weather must be watertight; except that, the following hatches may be weather-tight. Gaskets on weathertight doors to engine room were wasted.46 CFR 171.124
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 8 December 2021
Resolved 24 November 2021
Resolution: O/O provided pictures of replaced gaskets on doors.
01 - Certificates & Documentation › 011 - Ships Certificates › Other (certificates)
Issued 18 November 2020
Resolved
FCC bridge-to-bridge certificate was not issued to the vessel. Provide certificate to the vessel. 47 CFR 80.1001(a)
Condition: Improper Installation
Action required: 10 - Deficiency Rectified
Due 18 November 2020
Resolved 18 November 2020
Resolution: Owner had FCC certified technician issue bridge to bridge cert before we left inspection
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 18 November 2020
Resolved
One of the stowage compartments for child size life jackets was not properly marked for child life jackets. Mark compartment to indicate stowage of child size life jackets.
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 2 December 2020
Resolved 4 December 2020
Resolution: O/O sent photo evidence of properly labeled storage compartment. See documents for photo.
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 18 November 2020
Resolved
Fire hoses were observed not attached to fire hydrants and ready for immediate use. Attach hoses.46 CFR 181.15-10(2)(g)
Condition: Improper Installation
Action required: 10 - Deficiency Rectified
Due 18 November 2020
Resolved 18 November 2020
Resolution: Owner attached fire hoses
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 18 November 2020
Resolved
Screw down valve on port side forward collision bulkhead bilge pipe was inoperable. Repair or replace screw down valve arrangement so that is it operable from the weather deck -46CFR182.25-5(d)
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 2 December 2020
Resolved 23 November 2020
Resolution: The valve itself was changed and the existing rod leading from the deck was used. Stainless steel wire connects it to the handle on the valve. Sent photo evidence. Refer to photo in documents "def 1 clearance 18NOV20"
02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 18 November 2020
Resolved
Nonmetallic material is permitted for use in piping systems with certain restrictions. For the nonmetallic saltwater/grey water system piping that penetrates the watertight bulkhead between the #2 and #3 compartment on port side, install a metallic shut off valve adjacent to the through-bulkhead fitting if it can be operable from above the bulkhead deck; or, install two valves, one on either side of the bulkhead, and the valves would not need to be operated from above the bulkhead deck as long as there is immediate access to both valves. - 46CFR182.40-1(a)
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 2 December 2020
Resolved 24 November 2020
Resolution: O/O replaced PVC with metal piping that was between the ball valve and the watertight bulkhead (#2 and #3 compartment on port side). This repair was done on both sides of the bulkhead. Photos of both sides of the bulkhead have been uploaded "def 2/2a"
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 18 November 2020
Resolved
Install a blank in the open hole in the 120 volt distribution panel in portside engine room - 46CFR183.10-20(f)
Condition: Damaged By Earlier Event
Action required: 50 - Rectify deficiencies w/in 30 days
Due 18 December 2020
Resolved 23 November 2020
Resolution: The blank was filled with a metal plug from Cooper Electric. Picture included in documents.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 18 November 2020
Resolved
Multiple electrical outlets inside main deck accommodation area were found to have open grounds or the hot and neutral wires were reversed. Conduct testing on all outlets to discover all defective outlets and rewire correctly. - 46CFR183.10-20(f)
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 18 December 2020
Resolved 10 December 2020
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 19 November 2019
Resolved
Port and Starboard reach rods on bilge suction valves are disconnected from valve handles. Either repair connection or install screwdown valves aft of collision bulkheads. 46 CFR 182.500(d)
Action required: 50 - Rectify deficiencies w/in 30 days
Due 19 December 2019
Resolved 20 November 2019
Resolution: Owner repaird valve handles.
10 - Safety of Navigation › N/A - No Subsystem › Automatic Identification System (AIS)
Issued 9 August 2018
Resolved
Vsl is broadcasting: No static draft information and no dimension information (AIS Antenna Position ABCD values equals 0).
Condition: Invalid
Action required: 705 - Other - as specified
Due 9 September 2018
Resolved 19 November 2019
Resolution: ABCD location is now programmed. AIS does not transmit draft information.