← All vessels
MISS BARNEGAT LIGHT
Passenger (Inspected) · Passenger Ship class · Built 1970s · USCG East District (CGD-E) · Other hulls named MISS BARNEGAT LIGHT
MISS BARNEGAT LIGHT is a 1974 passenger vessel (inspected). The Coast Guard has recorded 90 inspections since 1985, most recently in April 2026, along with 158 deficiencies and 1 casualty investigation in 2011.
Records from 1985 to 2026. Most recent: inspection, 14 April 2026.
- Built
- 1974
- Last inspected
- 14 April 2026
- Documentation
- Valid · documentation file of 10 September 2026
- Deficiencies
- 158 recorded · 0 without a recorded resolution
- Controls
- None recorded without a removal date
- Casualties
- 1 investigation · 2011
Identity
555530
WDD4966
47912
Flag
UNITED STATES
367151830
Maury page id
psix-47912
Inspections, by type
…with no type recorded9
Years with a record
39 calendar years (1985–2026)
The 90 inspections in the strip above, split by the kind of activity the US
Coast Guard recorded. Years with a record are calendar years in which a record exists, not
years in service. What Maury does not do.
Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Passenger Ship class in Maury's sources begin in 1977.
Documentation record
Registered dimensions (L × B × D)76.7 ft × 32.0 ft × 6.9 ft
Registered tonnagegross 95 / net 64
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
BuilderBREAUX'S BAY CRAFT · LOREAUVILLE LA · built 1974
Hull materialAluminum
PropulsionDiesel Reduction
Hull shapeNot recorded
Hull configurationNot recorded
Hailing portPHILADELPHIA, PA
Trade endorsementsCoastwise, unrestricted, Fishery
DocumentationValid · issued 24 April 2026 · expires 31 May 2027
Service, as the file records itPassenger (Inspected)
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it95 - Regulatory (Subpart C or D), Gross Ton
64 - Regulatory (Subpart C or D), Net Ton
64 - Regulatory (Subpart C or D), Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 September 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.
Radio station licence
WDD4966MMSI 367151830 · active · compulsorily equipped · granted 28 October 2016, expires 21 November 2026
WYS7736MMSI not assigned · expired · compulsorily equipped · granted 4 November 1996, cancelled 16 December 2006
FCC Universal Licensing System ship-station file of 6 September 2026, matched to this hull on its
US Official Number. Status and dates are the file’s own. The licensee is not read from the file and is not shown.
A lapsed licence’s MMSI is still the number the vessel transmitted under while it was valid.
Inspection history · 90
14 April 2026
Internal Structural Exam · Examination of Repairs · Drydock Exam · Administrative Inspection · Vessel Attendance
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 8311404
18 November 2025
Annual Inspection · Internal Structural Exam · Administrative Inspection
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 8270164
19 March 2025
Administrative Inspection
Administrative · Sector Delaware Bay · USCG East District (CGD-E) · Activity 8096253
27 December 2024
Administrative Inspection
Administrative · Sector Delaware Bay · USCG East District (CGD-E) · Activity 8051145
19 November 2024
Annual Inspection · Internal Structural Exam
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 8036221
18 May 2024
Damage Survey
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 7915496
24 April 2024
Drydock Exam · Internal Structural Exam
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 7900962
16 November 2023
Annual Inspection
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 7827987
16 November 2022
Deficiency Check · Annual Inspection
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 7590819
20 April 2022
Drydock Exam · Internal Structural Exam
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 7434313
24 November 2021
Administrative Inspection
Administrative · Sector Delaware Bay · USCG East District (CGD-E) · Activity 7357068
13 October 2021
COI Inspection
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 7331654
18 November 2020
Annual Inspection · Deficiency Check
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 7095983
23 April 2020
Internal Structural Exam · Drydock Exam
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 6942721
19 November 2019
Annual Inspection
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 6858704
14 November 2018
Annual Inspection · DAPI Audit · Administrative Inspection
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 6578281
9 August 2018
Administrative Inspection
Administrative · Navigation Center · Activity 6505738
20 April 2018
Internal Structural Exam · Administrative Inspection · Hull Examination
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 6395890
13 November 2017
Annual Inspection
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 6306176
14 November 2016
COI Inspection · DAPI Audit
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 6040831
24 April 2016
Internal Structural Exam · Hull Examination · Deadweight Survey
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 5879904
24 November 2015
Administrative Inspection · COI Inspection · DAPI Audit
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 5803017
23 July 2015
Type not recorded
No type recorded · Station Barnegat Light · USCG East District (CGD-E) · Activity 5194045
14 May 2014
Administrative Inspection
Administrative · Sector Delaware Bay · USCG East District (CGD-E) · Activity 4858231
8 May 2014
Deficiency Check · Internal Structural Exam · Hull Examination
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 4877997
1 December 2011
Administrative Inspection
Administrative · Sector Delaware Bay · USCG East District (CGD-E) · Activity 4199664
30 September 2011
Type not recorded
No type recorded · Sector Delaware Bay · USCG East District (CGD-E) · Activity 4160683
23 November 2010
Annual Inspection
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 3897646
19 November 2008
Annual Inspection
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 3365280
17 April 2008
Hull Examination
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 3186023
14 November 2007
Annual Inspection
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 3096976
24 April 2007
Administrative Inspection
Administrative · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 2914386
12 April 2007
Administrative Inspection
Administrative · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 2906664
8 May 2006
Hull Examination · Internal Structural Exam
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 2641270
29 November 2005
Annual Inspection
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 2541522
23 November 2004
Annual Inspection
Physical examination · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 2237791
27 April 2004
Hull Examination
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 2048090
2 December 2003
Deficiency Check
Physical examination · Detached Duty Office Fort Myers · USCG Southeast District (CGD-SE) · Activity 1957254
20 November 2003
Annual Inspection
Physical examination · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 1952036
2 December 2002
Annual Inspection
Physical examination · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 1712548
24 July 2002
In-Service Inspection
Physical examination · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 1651229
30 April 2002
Hull Examination
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1608814
13 March 2002
Deficiency Check
Physical examination · Detached Duty Office Fort Myers · USCG Southeast District (CGD-SE) · Activity 1493679
17 January 2002
COI Inspection
Physical examination · Detached Duty Office Fort Myers · USCG Southeast District (CGD-SE) · Activity 1479442
18 June 2001
Deficiency Check
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1066743
22 January 2001
Re-Inspection
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1441780
12 May 2000
Hull Examination
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1458765
28 February 2000
Deficiency Check
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 815964
9 February 2000
Re-Inspection
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1412068
22 January 1999
COI Inspection
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1424700
15 May 1998
Hull Examination
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1426124
10 February 1998
Re-Inspection
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1404540
25 July 1997
Administrative
Administrative · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 779767
24 January 1997
Re-Inspection
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1377949
3 June 1996
Hull Examination
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1374625
6 March 1996
Type not recorded
No type recorded · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 885631
11 February 1996
Administrative
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1185846
25 January 1996
COI Inspection
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1193055
8 February 1995
COI Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1357002
24 January 1995
Examination of Repairs
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1426970
28 October 1994
Type not recorded
No type recorded · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 215145
26 October 1994
Type not recorded
No type recorded · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 70913
26 October 1994
Damage Survey
Physical examination · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 1358582
17 May 1994
Hull Examination
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 860091
2 February 1994
COI Inspection
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1163664
3 February 1993
Deficiency Check · COI Inspection
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1144388
7 May 1992
Hull Examination
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 956003
12 March 1992
Administrative
Administrative · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 955790
11 February 1992
COI Inspection
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 958030
16 September 1991
Administrative
Administrative · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1251990
8 May 1991
Deficiency Check
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1232229
12 February 1991
COI Inspection
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 911160
19 November 1990
Deficiency Check · Hull Examination
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 899358
19 November 1990
Type not recorded
No type recorded · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 910609
5 July 1990
Type not recorded
No type recorded · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 923916
7 June 1990
Type not recorded
No type recorded · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 903406
14 March 1990
Deficiency Check
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 920291
14 March 1990
Deficiency Check
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 929230
15 February 1990
COI Inspection
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 928220
2 May 1989
Hull Examination
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1200494
8 March 1989
Deficiency Check
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 895547
22 February 1989
COI Inspection
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1193985
4 May 1988
Deficiency Check
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1195454
15 March 1988
Deficiency Check · COI Inspection
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1339962
19 November 1987
Hull Examination
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1308060
4 May 1987
Hull Examination
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1335265
25 March 1987
COI Inspection
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1018807
10 April 1986
COI Inspection
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1307603
19 November 1985
Credit Drydock
Administrative · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 993385
11 April 1985
Type not recorded
No type recorded · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 981989
Deficiency record · 158
02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 18 November 2025
Resolved
Each vessel must meet the applicable requirements in Subchapter S of this chapter. Observed a hole in the port side collision bulkhead. Provide a temporary repair to the hole in the watertight collision bulkhead to the satisfaction of the attending marine inspector. Permanent repair to be completed in dry dock.
46 CFR 177.13-1 Old T
02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 18 November 2025
Resolved
Each vessel must meet the applicable requirements in Subchapter S of this chapter. Open cable run and two drill holes found on bulkhead separating engine and lazarette, also another open cable run on bulkhead 11 in the same compartment. Provide repairs to maintain watertight integrity on bulkheads to the satisfaction of attending marine inspector.
46 CFR 177.13-1 Old T
07 - Fire Safety › N/A - No Subsystem › Fire detection and alarm system
Issued 18 November 2025
Resolved
Vessels described by 46 CFR 175.110(c) must have an interconnected fire detection system in compliance with § 181.450 installed in all enclosed areas where passengers and crew have routine access, including accommodation spaces and machinery spaces. Vessel does not have interconnected fire detection in the machinery spaces. Provide interconnected fire detectors in port and starboard side engine spaces to the satisfaction of attending marine inspector. Vessel is restricted to Limited Coastwise until rectified.
46 CFR 181.405
09 - Working and Living Conditions › 092 - Working Conditions › Other (accident prevention)
Issued 18 November 2025
Resolved
Shall examine all accessible parts of the vessels, hull, machinery, and equipment to be assured that they are in satisfactory condition. Exhaust water line is secured overhead with the use of zip ties. Provide a suitable arrangement that is resistant to heat and wear to the satisfaction of attending marine inspector.
46 CFR 176.10-5(b)
Old T
01 - Certificates & Documentation › 013 - Documents › Log-books/compulsory entries
Issued 18 November 2025
Resolved
The owner of a vessel subject to inspection under section 3301 shall ensure that such vessel is equipped with a vessel master key control system, manual or electronic, which provides controlled access to all copies of the vessel’s master key of which access shall only be available to the individuals described in paragraph (2). Vessel does not have a master key control log. Provide log for master key control system.
46 U.S.C. § 3106
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 18 November 2025
Resolved
Each lifeline on a ring life buoy must: Have a breaking strength of at least 5 kilonewtons (1,124 pounds). Life buoy line was found rotted. Provide new lifeline for life buoy.
46 CFR 180.70(c)(5)
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 18 November 2025
Resolved
Placards containing instructions for the donning and use of the life jackets aboard the vessel must be posted in conspicuous places that are regularly accessible and visible to the crew and passengers. Vessel needs additional placard for the newer lifejackets onboard.
46 CFR 185.516(a)
10 - Safety of Navigation › N/A - No Subsystem › Charts
Issued 18 November 2025
Resolved
As appropriate for the intended voyage, a vessel must carry adequate and up-to-date: (1) Charts of large enough scale to make safe navigation possible; (2) U.S. Coast Pilot or similar publication; (3) Coast Guard Light List; (4) Tide tables; and (5) Current tables. Pubs are outdated.
09 - Working and Living Conditions › 092 - Working Conditions › Other (accident prevention)
Issued 18 November 2025
Resolved
Vessel control systems and other miscellaneous systems and equipment required by this part must be suitable for the purposes intended. Port side accommodation space heater has wasted guard. Replace guard on space heater.
46 CFR 184.100(a)
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 18 November 2025
Resolved
All electrical installations shall be to the satisfaction of the Officer in Charge, Marine Inspection. Exposed wires found on accommodation space overhead above port and starboard weathertight doors and starboard, forward overhead.
46 CFR 183.01-15 OLD T
08 - Alarms › N/A - No Subsystem › Other (alarms)
Issued 18 November 2025
Resolved
Gauges to indicate engine cooling water discharge temperature and lubricating oil pressure shall be provided for all propulsion engines and located so as to be in view of the operator. Vessels gauge display for port engine we intermittently operable. Rectify gauges to the satisfaction of attending marine inspector.
46 CFR 182.20-5(b)
Old T
02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 18 November 2025
Resolved
Shall examine all accessible parts of the vessels, hull, machinery, and equipment to be assured that they are in satisfactory condition. Leaks were found on the saltwater pipes in both port and starboard side machinery compartments further adding to the corrosion of the deck in both spaces. Secure leaks in both areas to the satisfaction of attending marine inspector.
46 CFR 176.10-5(b)
Old T
01 - Certificates & Documentation › 011 - Ships Certificates › Cargo Ship Safety Radio (including exemption)
Issued 18 November 2025
Resolved
Each vessel must carry a certificate with a valid endorsement while subject to the Bridge-to-Bridge Act. Vessel did not have Bridge to Bridge Act Certificate. Provide valid certificate.
47 CFR 80.1005
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 18 November 2025
Resolved
Each survival craft must be: Stowed so that when the vessel sinks the survival craft floats free and, if inflatable, inflates automatically. Hydrostatic releases on IBAs incorrectly rigged. Corrected by crew on the spot.
46 CFR 180.130(a)(2)
03 - Water/Weathertight Conditions › N/A - No Subsystem › Other (load lines)
Issued 19 November 2024
Resolved
Penetrations and openings in watertight bulkheads must have a means to make them watertight. MI observed several holes where previous cables were poking through bulkhead to another compartment. The machinery space on starboard side was observed to have cables going through forward bulkhead. Operator/Owner is to fill holes and ensure bulkhead is watertight.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 19 November 2024
Resolved
Wiring joints and splices shall be mechanically secure and made in junction boxes. MI observed loud hailer electrical wires were spliced and exposed to the outdoor elements. Operator/Owner shall protect and secure the wires according to regulation.
02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 19 November 2024
Resolved
Discharge pipe that penetrates the hull and at least 6 inches above the deepest load waterline must have a means to prevent water from entering the vessels is the pipe fractures or otherwise fails. MI observed a pipe that was not closed (capped) located in the forward machinery compartment. The Operator/Owner shall seal or cap the pipe to reduce the risk of pipe failure and prevent potential water leakage into the space.
02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 19 November 2024
Resolved
Internal combustion engine exhaust, and similar sources
of ignition shall be kept clear of and suitably insulated from any other combustible matter. MI observed the dry-exhaust from the generator in starboard and port lazarette space was not insulated or protected from other potential hazards. Operator shall insulate the dry-exhaust pipe for the generator in starboard and port lazarette space.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Machinery space openings
Issued 16 November 2022
Resolved
Bulkhead penetration fwd/stbd bulkhead of engine room. Ensure bulkhead is watertight.
07 - Fire Safety › N/A - No Subsystem › Fire pumps and its pipes
Issued 16 November 2022
Resolved
Fire pump found excessively leaking
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 10 November 2021
Resolved
All wiring and cables shall be suitable for marine service and for the particular installation used. Cap or remove hanging wiring on STBD side of engine room. 46CFR 183.10-20
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 10 November 2021
Resolved
All electrical installations shall be to the satisfaction of the Officer Charge, Marine Inspections. Open up generator and clean windings.
09 - Working and Living Conditions › 092 - Working Conditions › Pipes, wires (insulation)
Issued 10 November 2021
Resolved
When the flexible section is nonconductor of electricity, the metallic sections of the filling pipe separated thereby shall be joined by a conductor for protection against static spark when filling. Fuel fill pipe grounding was disconnected.46 CFR 182.15-30(d)
04 - Emergency Systems › N/A - No Subsystem › Emergency, lighting, batteries and switches
Issued 10 November 2021
Resolved
Batteries shall be located as high above the bilge as practicable and secured against shifting with motion of the boat. Batteries were not properly secured. Put nonconductive material between batteries to prevent movement. 46 CFR 183.05-20(b)
11 - Life Saving Appliances › N/A - No Subsystem › Maintenance of Life Saving Appliances
Issued 10 November 2021
Resolved
Each life ring buoy on a vessel must be approved in accordance with subchapter Q of this chapter. Life ring on upper deck STBD side was missing plug.46 CFR 180.70(b)(1)
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 10 November 2021
Resolved
That part of the exhaust system between the point of cooling water injection and the engine manifold shall be water jacketed or effectively insulated. Exhaust lagging on port side engine needs to be tightened up.46 CFR 182.15-15(b)(3)
03 - Water/Weathertight Conditions › N/A - No Subsystem › Doors
Issued 10 November 2021
Resolved
Each hatch exposed to the weather must be watertight; except that, the following hatches may be weather-tight. Gaskets on weathertight doors to engine room were wasted.46 CFR 171.124
01 - Certificates & Documentation › 011 - Ships Certificates › Other (certificates)
Issued 18 November 2020
Resolved
FCC bridge-to-bridge certificate was not issued to the vessel. Provide certificate to the vessel. 47 CFR 80.1001(a)
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 18 November 2020
Resolved
One of the stowage compartments for child size life jackets was not properly marked for child life jackets. Mark compartment to indicate stowage of child size life jackets.
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 18 November 2020
Resolved
Fire hoses were observed not attached to fire hydrants and ready for immediate use. Attach hoses.46 CFR 181.15-10(2)(g)
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 18 November 2020
Resolved
Screw down valve on port side forward collision bulkhead bilge pipe was inoperable. Repair or replace screw down valve arrangement so that is it operable from the weather deck -46CFR182.25-5(d)
02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 18 November 2020
Resolved
Nonmetallic material is permitted for use in piping systems with certain restrictions. For the nonmetallic saltwater/grey water system piping that penetrates the watertight bulkhead between the #2 and #3 compartment on port side, install a metallic shut off valve adjacent to the through-bulkhead fitting if it can be operable from above the bulkhead deck; or, install two valves, one on either side of the bulkhead, and the valves would not need to be operated from above the bulkhead deck as long as there is immediate access to both valves. - 46CFR182.40-1(a)
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 18 November 2020
Resolved
Install a blank in the open hole in the 120 volt distribution panel in portside engine room - 46CFR183.10-20(f)
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 18 November 2020
Resolved
Multiple electrical outlets inside main deck accommodation area were found to have open grounds or the hot and neutral wires were reversed. Conduct testing on all outlets to discover all defective outlets and rewire correctly. - 46CFR183.10-20(f)
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 19 November 2019
Resolved
Port and Starboard reach rods on bilge suction valves are disconnected from valve handles. Either repair connection or install screwdown valves aft of collision bulkheads. 46 CFR 182.500(d)
10 - Safety of Navigation › N/A - No Subsystem › Automatic Identification System (AIS)
Issued 9 August 2018
Resolved
Vsl is broadcasting: No static draft information and no dimension information (AIS Antenna Position ABCD values equals 0).
Stability › Intact Righting Energy › General
Issued 1 December 2011
Resolved
01 DEC 2011: Issued CG-835 with new passenger capacity due to change in AAWPP effective 01 Dec 2011.
Lifesaving › Lifejacket/PFD (General) › Condition
Issued 19 November 2008
Resolved
Two child size PFD are found un-sat and shall be replaced prior to carrying 14 or more children on board.
Fire Fighting › Fire Hoses › Condition
Issued 23 November 2004
Resolved
Provide replacement for faulty 1.5 inch fire hose (50 feet in length).
Construction/Loadline › Hull › Longitudinal Frame
Issued 23 November 2004
Resolved
Repair cracked weld on frames in crew quarters and port and starboard collision bulkheads.
Engineering › Bilge Water Management System › Pump
Issued 23 November 2004
Resolved
Prove proper operation of portable bilge pump.
Construction/Loadline › Hull › Hull Plating
Issued 27 April 2004
Resolved
Prep bilges to prevent further pitting throughout vessel as discussed. {Several areas in the voids have small pits. This can be prevented with a coat of some sort of preservative. Discussed with vessel rep the need to start a PM system, to save the hull. Vsl rep acknowledged. LEGACY COMPONENT DESC: Hull Plating
Engineering › Fuel Oil Storage/Transfer System
Issued 27 April 2004
Resolved
Repair fuel oil leak in PORT, AFT fuel oil tank prior to transiting back to NJ. Both AFT tanks are not to be filled with fuel while passengers are on board. Tanks may be used only after tanks are replaced or gauged to show proper thickness. LEGACY COMPONENT DESC: Tank
Engineering › Fuel Oil Storage/Transfer System › Tank
Issued 27 April 2004
Resolved
Prior to utilizing your AFT PORT and STBD fuel oil tanks, have tanks gauged to prove that they meet 46CFR182.440, and test tanks in the presence of a marine inspector as per 46CFR182.440(c). LEGACY COMPONENT DESC: Tank
Lifesaving › Lifejacket/PFD (Type I)
Issued 20 November 2003
Resolved
Vessel is restricted to 92 total persons in cold water, and 121 total persons in warm water operation. Condemed 33 adult life jackets. LEGACY COMPONENT DESC: Condition
Engineering › Compressed Air System (start air)
Issued 20 November 2003
Resolved
Prior to carrying passengers and in the presence of an attending Marine Inspector, conduct a hydrostatic air test of air reciever and relief valve. LEGACY COMPONENT DESC: Receiver/Bottle
Operations/Management › Lifesaving
Issued 20 November 2003
Resolved
Provide CRP cards for 50% of the crew.
Engineering › Fuel Oil Service System
Issued 20 November 2003
Resolved
Post emergency fuel shu-off placard on cabinet door, in which emergency fuel shut-off valve is located. Include direction arrow for opening and closing. LEGACY COMPONENT DESC: Valve
Construction/Loadline › Hull
Issued 20 November 2003
Resolved
Repair 3 cracks in bow space on stiffeners and 1 crack in crew quarters on starboard side. LEGACY COMPONENT DESC: Stiffener
Electrical
Issued 20 November 2003
Resolved
Remove dead-end wires in starboard machinery space.
Engineering › Sea-water System (primary cooling)
Issued 20 November 2003
Resolved
Install additional hose clamp and repair drip on port lazarette MDE wet exhaust pipe. LEGACY COMPONENT DESC: Piping
Lifesaving › Visual Distress Signals (General)
Issued 20 November 2003
Resolved
Replace ring buoy water light. Vessel is restricted to day light operations only until repaired and inspected. LEGACY COMPONENT DESC: Condition
Operations/Management
Issued 24 July 2002
Resolved
Prior to departing for Florida, conduct vessel reinspection through MSO Philadelphia.
Fire Fighting › Structural Fire Protection - General
Issued 23 July 2002
Resolved
Grill is to be taken out of service and not used. No fire fighting system and fire rating bulkheads around grill exist. LEGACY COMPONENT DESC: Cooking Area
Lifesaving › Buoyant Apparatus
Issued 23 July 2002
Resolved
Replace both sets of paddles on life floats.
Lifesaving › Lifebuoys
Issued 23 July 2002
Resolved
Replace aft port side water light on life float. LEGACY COMPONENT DESC: Self-igniting Lights
Pollution Prevention/Response › Prevention Equipment
Issued 23 July 2002
Resolved
Repair/replace both sewage holding tanks. LEGACY COMPONENT DESC: Marine Sanitation Device, Type III
Pollution Prevention/Response › Prevention Equipment
Issued 23 July 2002
Resolved
Replace both sewage overboard valves. LEGACY COMPONENT DESC: Marine Sanitation Device, Type III
Lifesaving › Lifejacket/PFD (General)
Issued 23 July 2002
Resolved
Replace 84 lights on adult and 8 lights on child life jackets. LEGACY COMPONENT DESC: Lights
Lifesaving › Inflatable Liferafts › Hydrostatic Release Unit
Issued 23 July 2002
Resolved
Replace expired hydro release on IBA, expired May 02
Construction/Loadline › Hull
Issued 23 July 2002
Resolved
Repair two cracked wframe, most forward in sewage space. LEGACY COMPONENT DESC: Weld
Construction/Loadline › Hull
Issued 23 July 2002
Resolved
Repair cracked frame in #3 compartment port side, outboard. LEGACY COMPONENT DESC: Longitudinal Frame
Construction/Loadline › Penetrations
Issued 23 July 2002
Resolved
Make forward hatch water tight. LEGACY COMPONENT DESC: Gasket
Lifesaving › Rigid Liferafts
Issued 23 July 2002
Resolved
Replace both weak links on life floats, both are missing tags. LEGACY COMPONENT DESC: Weak Link
Lifesaving › Rigid Liferafts
Issued 23 July 2002
Resolved
Attach proper grab lines on both life floats. LEGACY COMPONENT DESC: Painter
Construction/Loadline › Hull
Issued 23 July 2002
Resolved
Repair crackes welds in #1 compartment, forward frame where they tie into stem. LEGACY COMPONENT DESC: Weld
Electrical › Lighting (service)
Issued 17 January 2002
Resolved
PROVIDE GUARD FOR LIGHT FIXTURE IN FWD LIFEJACKET LOCKER. LEGACY COMPONENT DESC: Lighting Fixture
Communications › Radio Communications
Issued 17 January 2002
Resolved
PROVIDE AND INSTALL INLINE FUSE FOR VHF RADIO AT OPERATING STATION.
Navigation › Piloting/Steering
Issued 17 January 2002
Resolved
PROVIDE UPDATED DEVIATION TABLE AND CONDUCT MAINTENACE ON COMPASS. LEGACY COMPONENT DESC: Compass Deviation Table
Operations/Management › Navigation Safety
Issued 17 January 2002
Resolved
PROVIDE LOCATION AND COMMENCE WRITING A VOYAGE PLAN, SUBMIT VOYAGE PLAN TO MSD FT MYERS VIA FAX FOR NEXT 7 VOYAGES. LEGACY COMPONENT DESC: Navigation Underway, General
Operations/Management › Lifesaving
Issued 17 January 2002
Resolved
PROVIDE AND COMMENCE LOGGING LIFESAVING INSPECTIONS AND MAINTENACE. LEGACY COMPONENT DESC: Op Readiness/Maintenance/Inspection
Operations/Management › Drug and Alcohol Testing
Issued 17 January 2002
Resolved
CONDUCT EAP TRAINING FOR ALL CREW MEMBERS. LEGACY COMPONENT DESC: EAP Training Requirements
Personnel › Training
Issued 17 January 2002
Resolved
PROVIDE FIRST AID/CPR TRAINING FOR 50 PERCENT OF THE CREW. LEGACY COMPONENT DESC: First Aid/CPR
Electrical › Electrical Distribution System (service)
Issued 17 January 2002
Resolved
INSTALL COVER ON JUNCTION BOX FOR AUTO PILOT UNDER HELM CONSOLE. LEGACY COMPONENT DESC: Junction Box
Communications › Radio Communications
Issued 17 January 2002
Resolved
PROVIDE DOCUMENTATION THAT HYDRO-STATIC RELEASE ON EPIRB WAS PROPERLY SERVICED. LEGACY COMPONENT DESC: EPIRB
Lifesaving › Lifejacket/PFD (Type I)
Issued 17 January 2002
Resolved
PROVIDE 18 ADULT PFDS VESSEL IS RESTRICTED TO 136 TOTAL PERSONS UNTIL 18 ADULT PFDS ARE PROVIDED. LEGACY COMPONENT DESC: Condition
Fire Fighting › Portable CO2 Fire Extinguisher
Issued 17 January 2002
Resolved
CONDUCT ANNUAL SERVICING OF BI PORTABLE FIRE EXTINGUISHER. LEGACY COMPONENT DESC: Service
Fire Fighting › Miscellaneous Items
Issued 17 January 2002
Resolved
MOVE FIRE AXE FROM MACHINERY SPACE TO OPERATING STATION.
Fire Fighting › Fire Main › Condition
Issued 17 January 2002
Resolved
CROP AND RENEW FIRE HYDRANT PIPE ON MAIN DECK STARBOARD SIDE MID SHIPS. VESSEL RESTRICTED FROM CARRYING PASSENGERS FOR HIRE UNTIL CORRECTED.
Fire Fighting
Issued 22 January 2001
Resolved
SERVICE ALL PORTABLE FIRE EXTINGUISHERS.
Lifesaving
Issued 22 January 2001
Resolved
REPAIR/REPLACE WATERLIGHT ON LIFEFLOAT AND LIFE RING.
Fire Fighting
Issued 22 January 2001
Resolved
REPAIR VALVE ON STARBOARD FIRE STATION.
Lifesaving
Issued 22 January 2001
Resolved
INSTALL PLATFORM ON RESCUE LADDER.
Fire Fighting
Issued 22 January 2001
Resolved
REPAIR/REPLACE NOZZLE ON STARBOARD FIRE HOSE.
Accommodation/Occupational Safety
Issued 22 January 2001
Resolved
CALCULATE PASSENGER SEATING ON UPPER DECK AND MARK.
Fire Fighting
Issued 22 January 2001
Resolved
REPLACE STARBOARD FIRE HOSE.
Lifesaving
Issued 22 January 2001
Resolved
OBTAIN CONTENTS LIST FOR FIRST AID KIT.
Lifesaving
Issued 9 February 2000
Resolved
PROPERLY ATTACH SEA PAINTER ON THE 50 MAN LIFERAFT.
Lifesaving
Issued 9 February 2000
Resolved
PROVIDE 18 ADULT AND 1 CHILD PFD TO REPLACE THOSE REJECTED BY CG INSPECTOR.
Lifesaving
Issued 9 February 2000
Resolved
PROVIDE AND APPROVED FIRST AID KIT IAW 46CFR160.041-4.
Lifesaving
Issued 9 February 2000
Resolved
PROVIDE AND POST PFD DONNING PLACARDS FOR BOTH STYLE LIFEJACKETS.
Lifesaving
Issued 9 February 2000
Resolved
PROVIDE AND INSTALL 3 APPROVED RING BUOYS.
Navigation
Issued 9 February 2000
Resolved
PROVIDE AND POST EMERGENCY BROADCAST PLACARD.
Navigation
Issued 9 February 2000
Resolved
PROVIDE UP-TODATE CHARTS AND PUBS REQ'D ON THE VESSEL.
Lifesaving
Issued 9 February 2000
Resolved
PROVIDE PROOF OF EPIRB REGISTRATION WITH NOAA.
Engineering
Issued 9 February 2000
Resolved
OPEN UP AIR RECEIVER AT NEXT DRYDOCK AND IN NO CASE LATER THAN MAY, 2000.
Electrical
Issued 9 February 2000
Resolved
INSTALL DRIPPROOF RECEPTICLES IN WET LOCATIONS AND HARDWIRE INSTALLED ELECTRICAL EQUIPMENT THROUGH-OUT THE VESSEL.
Electrical
Issued 9 February 2000
Resolved
SECURE DOORS ON ALL ELECTRICAL PANELS LOCATED THROUGH-OUT THE VESSEL.
Electrical
Issued 9 February 2000
Resolved
PUT WOOD BLOCKING AROUND BATTERIES AS NEEDED TO PREVENT SHIFTING.
Construction/Loadline
Issued 9 February 2000
Resolved
REATTACH REMOTE REACH ROD FOR BOTH FORWARD BILGE SUCTION VALVES.
Engineering
Issued 9 February 2000
Resolved
REATTACH REMOTE REACH ROD FOR PORT FUEL OIL EMERGENCY SHUTOFF VALVE.
Construction/Loadline
Issued 26 October 1994
Resolved
PRIOR TO CARRYING PASSENGERS, MAKE PERMANENT REPAIRS TO A FOUR FOOT LONG TRANSVERSE FRACTURE OF THE BOTTOM PLATING AT THE COLLISION BULKHEAD AND RENEW ALL LONGITUDINAL BOTTOM PLATE STRENGTH MEMBERS IN WAY OF THE PLATE FRACTURE. SUBMIT REPAIR PROPOSAL TO COGNIZANT [name withheld] WORK.
Lifesaving
Issued 3 February 1993
Resolved
Repair one waterlight for lifefloat.
Lifesaving
Issued 3 February 1993
Resolved
Provide 13 additional adult pfd's. limited to not more than 140 total persons until completed.
Lifesaving
Issued 3 February 1993
Resolved
Provide 17 additional pfd lights.
Lifesaving
Issued 3 February 1993
Resolved
Renew one ring buoy and install reflective tape on both sides of other ringbuoys.
Lifesaving
Issued 3 February 1993
Resolved
Renew hand held signalling devices.
Fire Fighting
Issued 8 May 1991
Resolved
REPLACE PLASTIC FIRE HOSE NOZZLES WITH A TYPE MEETING 46 CFR 181.15-10 (D)(2).
Accommodation/Occupational Safety
Issued 12 February 1991
Resolved
INSTALL BRACKET FOR OVBD DISCHARGE VALVE CABLE ON PORT SEWAGE TANK TO ENSURE PROPER OPERATION. VALVE TO BE CLOSED LOCALLY UNTIL DONE.
Lifesaving
Issued 12 February 1991
Resolved
PROVIDE 6 ADDITIONAL ADULT PFD'S. VESSEL LIMITED TO 143 TOTAL PASSENGERS COASTWISE UNTIL COMPLETED.
Construction/Loadline
Issued 19 November 1990
Resolved
PERMANENTLY REPAIR UNDERDECK LONGITUDINAL TO 1ST TRANSVERSE JOINTS ACROSS TUNNEL AREA FWD COMPARTMENT PRIOR TO LEAVING MSO TAMPA ZONE.
Construction/Loadline
Issued 19 November 1990
Resolved
VEE OUT AND REWELD (1ST TRANS FRAME) CRACK IN PLT P HULL.
Construction/Loadline
Issued 19 November 1990
Resolved
VEE OUT AND REWELD 2 FRAMES AT 1ST TRANSVERSE FRAME WHERE ATTACHED TO STEM - P & S HULLS.
Accommodation/Occupational Safety
Issued 19 November 1990
Resolved
RENEW/REPAIR PORT SEWAGE TANK.
Deck/Cargo
Issued 19 November 1990
Resolved
INSTALL BILGE STRAINER 3RD COMPT AFT, PORT.
Construction/Loadline
Issued 19 November 1990
Resolved
VEE OU AND REWELD AFT ER BHD WHERE CRACKED AROUND OUTBOARD EXH AND BHD BWLOE (1-2" BELOW EXH.) PORT.
Construction/Loadline
Issued 19 November 1990
Resolved
PORT BOW - 2 EXT CRACK UNDER RUBRAIL.
Accommodation/Occupational Safety
Issued 19 November 1990
Resolved
REMOVE EXISTING PIPING FROM TOILET 4" LINE TO DECK DRAIN PIPING. SEWAGE NOW GOES OVERBOARD.
Construction/Loadline
Issued 19 November 1990
Resolved
PERMANENTLY ATTCH COLLISION BHD REACH RODS.
Engineering
Issued 19 November 1990
Resolved
INSTALL ALL BOLTS P&S AFT FUEL TANK COVERS.
Engineering
Issued 19 November 1990
Resolved
REPAIR EXH LEAK PORT STERN COMPT.
Navigation
Issued 19 November 1990
Resolved
INSTALL NEW PINS WITH LOCKNUTS OR COTTER KEYS - PORT RUDDER LINKAGE AT QUADRANT AND NEW PIN AT PORT RAM FOUNDATION.
Construction/Loadline
Issued 19 November 1990
Resolved
REWELD STBD KEEL COOLER LEAKS.
Navigation
Issued 19 November 1990
Resolved
REWELD PORT RUDDER CRACKS.
Construction/Loadline
Issued 19 November 1990
Resolved
VEE OUT AND REWELD BHD CRACK (AROUND INBOARD EXH AREA) STBD AFT VOID FWD BHD. VERTICAL CRACK.
Deck/Cargo
Issued 19 November 1990
Resolved
INSTALL BILGE STRAINER STBD AFT COMPT.
Accommodation/Occupational Safety
Issued 19 November 1990
Resolved
REPAIR AND DEMONSTRATE REMOTE SEWAGE VALVE OPERATORS. (1 1/2" - 2")
Construction/Loadline
Issued 19 November 1990
Resolved
PERMANENTLY REPAIR UNDERDECK LONGITUDINAL TO 1ST TRANSVERSE JOINTS ACCROSS TUNNEL AREA FWD COMPARTMENT PRIOR TO LEAVING MSO TAMPA ZONE.
Lifesaving
Issued 7 June 1990
Resolved
MARK THE LIFE FLOATS WITH THE VESSEL'S NAME AND CAPACITY.
Lifesaving
Issued 7 June 1990
Resolved
HAVE THE LIFE RAFT SERVICED, PRESENTLY OVERDUE. VESSEL IS RESTRICTED TO 120 PASSENGERS ON COASTWISE VOYAGES AND 60 PASSENGERS ON OCEAN VOYAGES UNTIL COMPLETE.
Navigation
Issued 7 June 1990
Resolved
MOVE THE SIDELIGHTS AFT OF THE FORWARD MASTHEAD LIGHT TO COMPLY WITH ANNEX I TO THE 1980 COLREGS.
Construction/Loadline
Issued 7 June 1990
Resolved
RENEW THE CAPTIVE CHAIN ON THE AFT STARBOARD HATCH.
Navigation
Issued 7 June 1990
Resolved
PROVIDE LIGHT LIST VOL. 1, COAST PILOT #3 AND CHART 12323.
Engineering
Issued 15 February 1990
Resolved
PROVIDE HEAT SHIELDS FOR THE FTOUR DAHL FUEL ENGINES.
Engineering
Issued 15 February 1990
Resolved
RENEW FLAME SCREENS IN THE 4 FUEL VENTS.
Lifesaving
Issued 15 February 1990
Resolved
PROVIDE ADEQUACY OF VESSEL AS A RESCUE PLATFORM.
Fire Fighting
Issued 15 February 1990
Resolved
PROVIDE AN APPROVED MARINE BRACKET FOR THE GALLEY B-II FIRE EXTINGUISHER.
Accommodation/Occupational Safety
Issued 15 February 1990
Resolved
PROVIDE MEANS TO DISABLE/LOCK SEWAGE OVERBOARD VALVES. VALVES TO BE CLOSEDWHILE WITHIN THE TERRITORIAL WATERS.
Electrical
Issued 15 February 1990
Resolved
PROVIDE BLANKS FOR THE EXPOSED SPACES IN THE CIRCUIT BREAKER BOX.
Lifesaving
Issued 15 February 1990
Resolved
PROVIDE 15 APPROVED ADULT LIFE PRESERVERS. THE VESSEL IS RESTRICTED TO 134PASSENGERS UNTIL COMPLETED.
Documentation
Issued 2 May 1989
Resolved
DRYDOCK DUE 02NOV90. CONTACT USCG PRIOR TO THIS DATE TO SCHEDULE THIS INSPECTION.
Deck/Cargo
Issued 22 February 1989
Resolved
REMOVE OIL FROM ENGINE ROOM BILGE PRIOR TO CARRYING PASSENGERS.
Fire Fighting
Issued 22 February 1989
Resolved
PROVE FIRE PUMPS CAPABLE OF 60 PSI AT PUMP OUTLET.
Fire Fighting
Issued 22 February 1989
Resolved
REPAIR LEAK IN STBD FIRE/BILGE MAIN.
Accommodation/Occupational Safety
Issued 22 February 1989
Resolved
INSTALL GLOBES AND GUARDS AS NEEDED.
Lifesaving
Issued 22 February 1989
Resolved
PROVIDE UN-EXPIRED FLARES.
Lifesaving
Issued 22 February 1989
Resolved
PROVIDE HYDRO RELEASES FOR LIFERAFTS.
Documentation
Issued 22 February 1989
Resolved
DRYDOCK DUE 19MAY89. CONTACT USCG PRIOR TO THIS DATE TO SCHEDULE THIS INSPECTION.
Fire Fighting
Issued 22 February 1989
Resolved
PROIDE SUCTION AND DISCHARGE HOSES FOR HAND PORTABLE FIRE AND BILGE PUMP.
Lifesaving
Issued 22 February 1989
Resolved
PROVIDE 9 ADULT PFD'S PRIOR TO CARRYING MORE THAN 145 ADULT PERSONS.
Lifesaving
Issued 4 May 1988
Resolved
PROVIDE 1 ADULT PFD AND STENCIL VESSEL NAME WITH NIGHT LIGHT.
Documentation
Issued 15 March 1988
Resolved
RENEW VESSEL'S FCC RADIO SAFETY CERTIFICATES.
Lifesaving
Issued 15 March 1988
Resolved
PROVIDE 23 ADULT PFD'S PRIOR TO CARRYING MORE THAN 131 ADULTS ON A COASTWISE VOYAGE.
Construction/Loadline
Issued 15 March 1988
Resolved
INSTALL CAPTURE CHAINS ON ALL WEATHER DECK HATCHES.
Lifesaving
Issued 15 March 1988
Resolved
RESTENCIL VESSEL'S NAME ON ALL PFD'S AS NEEDED WHERE IT HAS FADED OR BEEN PARTIALLY COVERED BY THE INSTALLED RETROFLECTIVE TAPE.
Fire Fighting
Issued 15 March 1988
Resolved
INSTALL A BRONZE OR OTHER CORROSIVE RESISTANT MATEIAL NOZZLE FOR THE PORT FIRE STATION.
Engineering
Issued 15 March 1988
Resolved
INSTALL 30X30 CORROSIVE RESISTANT MESH FLAMESCREENS FOR AFT FUEL TANKS PRIOR TO USING THESE TANKS.
Lifesaving
Issued 11 April 1985
Resolved
REPLACE TOTAL OF SEVEN P.F.D.'S TO CONFORM WITH C.O.I. REQUIRMENTS. TOTAL PASSENGERS ALLOWED COASTWISE LOWERED TO 142 UNTIL ITEM IS CLEARED.
Casualty record · 1
30 September 2011Routine · role: Involved in a Marine Investigation (non-casualty) · 1 dead · activity 4160683
Each line is an incident investigation the Coast Guard recorded with this hull among the vessels involved, with the date and the classification the Coast Guard gave it, and the bridge, lock or dam the investigation names where it names one. Involvement is not fault. The investigation narrative is not published. Source: IIR, through 2026.
Ownership record
The Coast Guard's documentation record for this hull -- the Abstract of Title,
with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National
Vessel Documentation Center, files it here with its date, and every reader of this page gets it.