MAURY USCG vessel records Sign in
← All vessels

ADMIRALTY WIND

ADMIRALTY WIND is a 1998 passenger vessel (inspected). The Coast Guard has recorded 66 inspections since 1998, most recently in December 2025, along with 106 deficiencies and 2 casualty investigations between 2009 and 2012.

Records from 1998 to 2025. Most recent: inspection, 3 December 2025.

Built
1998
Last inspected
3 December 2025
Documentation
Valid · documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

WCY7687
479122
Flag
UNITED STATES
367375470
Maury page id
psix-479122

Inspections, by type

…with no type recorded4
Years with a record 25 calendar years (1998–2025)
The 66 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Passenger Ship class in Maury's sources begin in 1977.

Documentation record

Registered dimensions (L × B × D)88.1 ft × 22.8 ft × 9.0 ft
Registered tonnagegross 99 / net 67
ITC dimensions (L × B × D)88.1 ft × 22.8 ft × 9.0 ft
ITC tonnagegross 198 / net 68
BuilderWESTPORT SHIPYARD, INC. · WESTPORT, WA, UNITED STATES · built 1998
Hull materialFRP (Fiberglass)
PropulsionDiesel Reduction
Hull shapeNot recorded
Hull configurationNot recorded
Hailing portJUNEAU, AK
Trade endorsementsCoastwise, unrestricted, Fishery, Recreational, Registry
DocumentationValid · issued 8 January 2026 · expires 31 January 2027
Service, as the file records itPassenger (Inspected)
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it68 - Convention (Subpart B), Net Ton
67 - Regulatory (Subpart C or D), Net Ton
198 - Convention (Subpart B), Gross Ton
99 - Regulatory (Subpart C or D), Gross Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 September 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.

Radio station licence

WCY7687MMSI 367375470 · active · compulsorily equipped · granted 5 September 2018, expires 16 November 2028
FCC Universal Licensing System ship-station file of 6 September 2026, matched to this hull on its US Official Number. Status and dates are the file’s own. The licensee is not read from the file and is not shown. A lapsed licence’s MMSI is still the number the vessel transmitted under while it was valid.

Inspection history · 66

3 December 2025 Annual Inspection · Internal Structural Exam · Deficiency Check
Physical examination · Sector Southeast Alaska · USCG Arctic District (CGD-A) · Activity 8273927
30 January 2025 Examination of Repairs
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 8072163
23 January 2025 Administrative Inspection · Plan Review "T" Boat
Administrative · Sector Southeast Alaska · USCG Arctic District (CGD-A) · Activity 8069187
30 October 2024 Annual Inspection · Internal Structural Exam · Deficiency Check
Physical examination · Sector Southeast Alaska · USCG Arctic District (CGD-A) · Activity 8026980
25 September 2024 Internal Structural Exam · Drydock Exam
Physical examination · Sector Southeast Alaska · USCG Arctic District (CGD-A) · Activity 8008670
10 January 2024 Annual Inspection · Deficiency Check
Physical examination · Sector Southeast Alaska · USCG Arctic District (CGD-A) · Activity 7847408
9 November 2022 Annual Inspection · Deficiency Check
Physical examination · Sector Southeast Alaska · USCG Arctic District (CGD-A) · Activity 7581164
28 September 2022 Internal Structural Exam · Hull Examination · Deficiency Check · Administrative Inspection
Physical examination · Sector Southeast Alaska · USCG Arctic District (CGD-A) · Activity 7555229
18 November 2021 Deficiency Check · Plan Review "T" Boat
Physical examination · Sector Southeast Alaska · USCG Arctic District (CGD-A) · Activity 7353731
9 November 2021 Deficiency Check
Physical examination · Sector Southeast Alaska · USCG Arctic District (CGD-A) · Activity 7348411
19 October 2021 Deficiency Check · COI Inspection
Physical examination · Sector Southeast Alaska · USCG Arctic District (CGD-A) · Activity 7335602
29 December 2020 Deficiency Check
Physical examination · Sector Southeast Alaska · USCG Arctic District (CGD-A) · Activity 7117554
10 November 2020 Annual Inspection
Physical examination · Sector Southeast Alaska · USCG Arctic District (CGD-A) · Activity 7095089
24 September 2020 Hull Examination · Administrative Inspection · Internal Structural Exam
Physical examination · Sector Southeast Alaska · USCG Arctic District (CGD-A) · Activity 7067053
4 November 2019 Deficiency Check
Physical examination · Sector Southeast Alaska · USCG Arctic District (CGD-A) · Activity 6850686
30 October 2019 Deficiency Check · Administrative Inspection · Annual Inspection
Physical examination · Sector Southeast Alaska · USCG Arctic District (CGD-A) · Activity 6845604
21 October 2019 Deficiency Check · In-Service Inspection
Physical examination · Sector Southeast Alaska · USCG Arctic District (CGD-A) · Activity 6841109
8 October 2019 Administrative Inspection
Administrative · Sector Southeast Alaska · USCG Arctic District (CGD-A) · Activity 6830998
8 November 2018 Annual Inspection
Physical examination · Sector Southeast Alaska · USCG Arctic District (CGD-A) · Activity 6579931
7 November 2018 Deficiency Check · Administrative Inspection
Physical examination · Marine Safety Detachment Sitka · USCG Arctic District (CGD-A) · Activity 6576844
25 September 2018 Drydock Exam
Physical examination · Marine Safety Detachment Sitka · USCG Arctic District (CGD-A) · Activity 6539862
21 February 2018 Administrative Inspection
Administrative · Navigation Center · Activity 6358720
7 November 2017 Deficiency Check
Physical examination · Sector Southeast Alaska · USCG Arctic District (CGD-A) · Activity 6302855
23 October 2017 Annual Inspection · DAPI Audit
Physical examination · Sector Southeast Alaska · USCG Arctic District (CGD-A) · Activity 6293321
30 September 2016 Hull Examination · Internal Structural Exam
Physical examination · Marine Safety Detachment Sitka · USCG Arctic District (CGD-A) · Activity 6013611
7 September 2016 COI Inspection
Physical examination · Sector Southeast Alaska · USCG Arctic District (CGD-A) · Activity 5994452
15 December 2015 Deficiency Check
Physical examination · Sector Southeast Alaska · USCG Arctic District (CGD-A) · Activity 5782532
3 December 2015 Annual Inspection
Physical examination · Sector Southeast Alaska · USCG Arctic District (CGD-A) · Activity 5775079
2 November 2015 Administrative Inspection
Administrative · Sector Southeast Alaska · USCG Arctic District (CGD-A) · Activity 5755997
29 October 2014 Administrative Inspection · Deficiency Check
Physical examination · Sector Southeast Alaska · USCG Arctic District (CGD-A) · Activity 5013948
13 July 2012 Administrative Inspection
Administrative · Sector Southeast Alaska · USCG Arctic District (CGD-A) · Activity 4377931
9 January 2012 In-Service Inspection · Deficiency Check
Physical examination · Sector Southeast Alaska · USCG Arctic District (CGD-A) · Activity 4222971
17 November 2010 Annual Inspection
Physical examination · Sector Southeast Alaska · USCG Arctic District (CGD-A) · Activity 3900335
5 January 2009 Type not recorded
No type recorded · Sector Southeast Alaska · USCG Arctic District (CGD-A) · Activity 3398604
3 November 2008 Annual Inspection
Physical examination · Sector Southeast Alaska · USCG Arctic District (CGD-A) · Activity 3356481
26 September 2008 Hull Examination
Physical examination · Sector Southeast Alaska · USCG Arctic District (CGD-A) · Activity 3335135
8 January 2008 Administrative Inspection
Administrative · Sector Southeast Alaska · USCG Arctic District (CGD-A) · Activity 3127596
14 November 2007 Annual Inspection
Physical examination · Sector Southeast Alaska · USCG Arctic District (CGD-A) · Activity 3098325
29 September 2006 Hull Examination
Physical examination · Sector Southeast Alaska · USCG Arctic District (CGD-A) · Activity 2790037
14 November 2005 Annual Inspection
Physical examination · MSO JUNEAU · USCG Arctic District (CGD-A) · Activity 2534614
3 November 2005 In-Service Inspection
Physical examination · MSO JUNEAU · USCG Arctic District (CGD-A) · Activity 2531677
25 December 2004 Damage Survey · Re-Inspection · Deficiency Check
Physical examination · MSO JUNEAU · USCG Arctic District (CGD-A) · Activity 2265236
25 December 2004 Type not recorded
No type recorded · MSO JUNEAU · USCG Arctic District (CGD-A) · Activity 2281427
22 November 2004 Deficiency Check
Physical examination · MSO JUNEAU · USCG Arctic District (CGD-A) · Activity 2244601
20 October 2004 Internal Structural Exam · Hull Examination · Deficiency Check · Annual Inspection
Physical examination · MSO JUNEAU · USCG Arctic District (CGD-A) · Activity 2215865
13 October 2004 Administrative Inspection
Administrative · Marine Safety Center (MSC) · Activity 2219826
4 October 2004 Administrative Inspection
Administrative · MSO JUNEAU · USCG Arctic District (CGD-A) · Activity 2213030
22 December 2003 Security Plan Review - ASP
Administrative · Marine Safety Center (MSC) · Activity 1970882
4 November 2003 Re-Inspection · Deficiency Check
Physical examination · MSO JUNEAU · USCG Arctic District (CGD-A) · Activity 1943455
14 January 2003 Deficiency Check
Physical examination · MSO JUNEAU · USCG Arctic District (CGD-A) · Activity 1773688
17 December 2002 Annual Inspection
Physical examination · MSO JUNEAU · USCG Arctic District (CGD-A) · Activity 1708325
22 October 2002 Hull Examination · Internal Structural Exam
Physical examination · MSO JUNEAU · USCG Arctic District (CGD-A) · Activity 1686173
15 January 2002 Type not recorded
No type recorded · MSO JUNEAU · USCG Arctic District (CGD-A) · Activity 1478809
14 November 2001 COI Inspection
Physical examination · MSO JUNEAU · USCG Arctic District (CGD-A) · Activity 1384930
17 July 2001 Deficiency Check
Physical examination · MSO JUNEAU · USCG Arctic District (CGD-A) · Activity 1067100
15 March 2000 Administrative
Administrative · MSO JUNEAU · USCG Arctic District (CGD-A) · Activity 1046208
18 February 2000 Deficiency Check
Physical examination · MSO JUNEAU · USCG Arctic District (CGD-A) · Activity 815455
31 January 2000 Administrative
Administrative · MSO JUNEAU · USCG Arctic District (CGD-A) · Activity 1045875
25 January 2000 Deficiency Check
Physical examination · MSO JUNEAU · USCG Arctic District (CGD-A) · Activity 814766
3 December 1999 Re-Inspection
Physical examination · MSO JUNEAU · USCG Arctic District (CGD-A) · Activity 1421775
19 January 1999 Deficiency Check
Physical examination · MSO JUNEAU · USCG Arctic District (CGD-A) · Activity 1365021
31 December 1998 Deficiency Check
Physical examination · MSO JUNEAU · USCG Arctic District (CGD-A) · Activity 1364984
11 December 1998 Damage Survey · Examination of Repairs
Physical examination · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 1372435
3 December 1998 Damage Survey
Physical examination · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 1384007
2 December 1998 Type not recorded
No type recorded · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 67356
18 November 1998 Initial Construction-Excluding Oversight · Initial Certification · Hull Examination
Physical examination · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 1451348

Deficiency record · 106

07 - Fire Safety › N/A - No Subsystem › Fire pumps and its pipes
Issued 3 December 2025 Resolved
Piping, valves, and fittings in a fire main system must comply with subpart G, part 182, of this chapter. Fire main has a leak (drop a second) close to branching of line (ivo gauge/before the front portion of stbd M/E) to fwd section of the vessel. To be repaired within 7 days (10DEC2025). 46CFR181.310(b)
Action required: 705 - Other - as specified
Resolved 12 December 2025
Resolution: Fire main connection was soldered. Pressed up fire main, no leaks observed.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 3 December 2025 Resolved
Exhaust gas must not leak from the piping or any connections. Stbd engine secondary exhaust cooling pump inject point is leaking. 46CFR182.430(b)
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 12 December 2025
Resolution: Injection point was re sealed; no leaking observed.
10 - Safety of Navigation › N/A - No Subsystem › Lights, shapes, sound-signals
Issued 3 December 2025 Resolved
All vessels must have navigation lights that are in compliance. Anchor light is not operational. 46CFR183.420
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 12 December 2025
Resolution: Anchor light was replaced and verified; all sat.
09 - Working and Living Conditions › 091 - Living Conditions › Medical Equipment
Issued 3 December 2025 Resolved
A vessel must carry either a first-aid kit that meets the requirements in 46 CFR 199.175(b)(10) or a kit with equivalent contents and instructions. Onboard first aid kit does not meet standard. 46CFR184.710
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 12 December 2025
Resolution: First aid kit updated to regulation; all sat.
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 30 October 2024 Resolved
Piping used in a vital system must: (1) Be composed of ferrous materials. (2) If subject to a pressure of more than 1,034 kPa (150 psig), be designed, fabricated, and inspected in accordance with the principles of ANSI B 31.1 (incorporated by reference; see 46 CFR 175.600) or other standard specified by the Commandant. Fire main piping has a pin-hole leak. Repair to satisfaction of attending USCG Marine Inspector.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 15 November 2024
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 30 October 2024 Resolved
In systems and applications where flexible hoses are permitted to be clamped: Double hose clamping is required where practicable; Two clamps must be used on each end of the hose, or one hose clamp can be used if the pipe ends are expanded or beaded to provide a positive stop against slippage. Install double hose clamps where required.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 15 November 2024
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 30 October 2024 Resolved
Fire pumps: (b) On a vessel of more than 19.8 meters (65 feet) in length, the minimum capacity of the fire pump must be 189 liters (50 gallons) per minute at a pressure of not less than 414 kPa (60 psi) at the pump outlet. The pump outlet must be fitted with a pressure gauge. Fire pump pressure gauge is inop, repair/replace gauge as required. To be rectified by 06 NOV 2024.
Action required: 705 - Other - as specified
Due 6 November 2024
Resolved 15 November 2024
14 - Pollution Prevention › 144 - MARPOL Annex IV (Not Applicable to PSC Exams conducted in the U.S.) › Sewage treatment plant
Issued 30 October 2024 Resolved
Each marine sanitation device must - Be designed to prevent the overboard discharge of treated or untreated sewage or any waste derived from sewage. Make repairs to suspected leaks on Port sewage holding tank.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 13 November 2024
Resolved 27 November 2024
05 - Radio Communications › N/A - No Subsystem › Other (radio communication)
Issued 30 October 2024 Resolved
47 CFR 80.401 - Licensees of radio stations are required to have current station documents. Update station license to reflect current EPIRB registration and total persons allowed as per COI.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 13 November 2024
Resolved 12 December 2025
Resolution: New station license issued with EPIRB certification indicating correct total persons onbaord.
05 - Radio Communications › N/A - No Subsystem › Other (radio communication)
Issued 30 October 2024 Resolved
47 CFR 80.155 - Operation of transmitters of any ship station must be performed by a person holding a commercial radio operator license or permit. Provide documentation that operator has obtained Ship station operator permit.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 13 November 2024
Resolved 27 May 2025
Resolution: Provided permit
04 - Emergency Systems › N/A - No Subsystem › Emergency fire pump and its pipes
Issued 30 October 2024 Resolved
Provide written proposal for conducting internal inspection of fire-main to determine current overall condition. Inspection to be conducted in the presence of attending Marine Inspector. Proposal to be submitted no later than 08 November 2024.
Action required: 705 - Other - as specified
Due 8 November 2024
Resolved 12 November 2024
Resolution: Proposal recieved.
04 - Emergency Systems › N/A - No Subsystem › Emergency fire pump and its pipes
Issued 30 October 2024 Resolved
Provide required OCMI plan approval for fire-main system to include material specifications. Provide requested information no later than 15 November 2024.
Action required: 705 - Other - as specified
Due 15 November 2024
Resolved 28 March 2025
Resolution: Requested information provided
04 - Emergency Systems › N/A - No Subsystem › Emergency fire pump and its pipes
Issued 30 October 2024 Resolved
Conduct internal inspection of fire-main piping in presence of attending Marine Inspector. Conduct internal inspection no later than 14 November 2024.
Action required: 705 - Other - as specified
Due 14 November 2024
Resolved 15 November 2024
Resolution: Fire main internal inspection conducted in presence of attending marine inspector.
07 - Fire Safety › N/A - No Subsystem › Fire pumps and its pipes
Issued 30 October 2024 Resolved
Except as otherwise permitted, piping systems must be subjected to a hydrostatic test pressure that at every point in the system is not less than 1.5 times the maximum allowable working pressure for a minimum of 10 minutes. Fire main max pressure 60 psi, test pressure 80psi. 46CFR 56.97-30(d)(e)
Action required: 705 - Other - as specified
Due 14 November 2024
Resolved 15 November 2024
Resolution: System repaired and tested to the satisfaction of attending marine inspector
07 - Fire Safety › N/A - No Subsystem › Fire pumps and its pipes
Issued 30 October 2024 Resolved
Where nonferrous metallic material is permitted for use in piping systems, provisions must be made to prevent or mitigate the effect of galvanic corrosion due to the relative solution potentials of copper used in conjunction with steel, or other metals and their alloys. Replace existing steel fire pump with bronze/non ferrous pump as originally approved and designed. Replacement to be conducted during dry dock scheduled 04Mar2024. To be completed prior to returning to service. 46 CFR 182.730(b)(2)
Action required: 705 - Other - as specified
Due 31 March 2025
Resolved 14 May 2025
Resolution: System/pump replaced
07 - Fire Safety › N/A - No Subsystem › Fire pumps and its pipes
Issued 30 October 2024 Resolved
Nonferrous metallic piping with a melting temperature above 1,700 degrees F may be used when specifically accepted by the [name withheld] un-approved repairs (09) in engine room IWO fire pump and (02) in crew accommodation space with sweat type connections as per original approved design. 46 CFR 182.730(a)(4)
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 27 November 2024
07 - Fire Safety › N/A - No Subsystem › Fire pumps and its pipes
Issued 30 October 2024 Resolved
Except as otherwise permitted, piping systems must be subjected to a hydrostatic test pressure that at every point in the system is not less than 1.5 times the maximum allowable working pressure for a minimum of 10 minutes. Fire main max pressure 60 psi, test pressure 80psi is max output pressure of pump. Conduct required pressure test upon completion of fire main piping repairs in engine room and crew accommodation space. 46CFR 56.97-30(d)(e)
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 22 November 2024
Resolution: Pump tested to the satisfaction of attending Marine Inspector
05 - Radio Communications › N/A - No Subsystem › Satellite EPIRB 406MHz/1.6GHz
Issued 10 January 2024 Resolved
Each disposable hydrostatic release unit must be marked with an expiration date of two years after the date on which the unit is installed. EPIRB hydrostatic release unit expired on 09/2023. Renew hydrostatic release unit. 46 CFR 185.740(b)
Condition: Placed in Improper Service
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 30 October 2024
Resolution: MI attended. Deficiency rectified.
01 - Certificates & Documentation › 013 - Documents › Stability Information Booklet
Issued 10 January 2024 Resolved
When, in accordance with § 178.210 of this chapter, a vessel must be provided with a stability letter, the stability letter must be posted under glass or other suitable transparent material, such that all pages are visible, at the operating station of the vessel. Stability letter was posted in the passenger accommodation space on the main deck. Post stability letter at the operating station. 46 CFR 176.306
Condition: Placed in Improper Service
Action required: 16 - Rectify deficiencies w/in 14 days
Due 24 January 2024
Resolved 30 October 2024
Resolution: MI attended. Stability letter posted in the pilot house.
10 - Safety of Navigation › N/A - No Subsystem › Nautical publications
Issued 10 January 2024 Resolved
As appropriate for the intended voyage, a vessel must carry adequate and up-to-date: U.S. Coast Pilot or similar publication and Coast Guard Light List. Extracts from the publications listed above for the areas to be transited may be provided instead of the complete publication. Coast Pilot and Light List were dated. Provide up-to-date publications. 46 CFR 184.420
Action required: 16 - Rectify deficiencies w/in 14 days
Due 24 January 2024
Resolved 30 October 2024
Resolution: MI attended. Deficiency rectified.
09 - Working and Living Conditions › 091 - Living Conditions › Medical Equipment
Issued 10 January 2024 Resolved
A vessel must carry either a first-aid kit that meets the requirements in 46 CFR 199.175(b)(10) or a kit with equivalent contents and instructions. First aid kit aspirin and eye wash were expired. Renew medication. 46 CFR 184.710
Action required: 16 - Rectify deficiencies w/in 14 days
Due 24 January 2024
Resolved 30 October 2024
Resolution: MI attended. Deficiency rectified.
07 - Fire Safety › N/A - No Subsystem › Remote Means of control (opening,pumps,ventilation,etc.) Machinery spaces
Issued 10 January 2024 Resolved
Remote fuel shutoff stations must be marked in clearly legible letters at least 1 inch high indicating purpose of the valve and direction of operation. Labeling for fuel shutoff valves was either missing or worn. Renew labeling. 46 CFR 185.608
Action required: 16 - Rectify deficiencies w/in 14 days
Due 24 January 2024
Resolved 30 October 2024
Resolution: MI attended. Deficiency rectified.
04 - Emergency Systems › N/A - No Subsystem › Abandon ship drills
Issued 10 January 2024 Resolved
Abandon ship, man overboard and fire fighting drills and training shall be logged or otherwise documented for review by the Coast Guard. The drill entry shall include the following information: Date of the drill and training and general description of the drill scenario and training topics. Drills were not being logged. Educated operator on the proper method of logging drills. 46 CFR 185.520(f) & 46 CFR 185.524(d)
Action required: 10 - Deficiency Rectified
Resolved 10 January 2024
Resolution: Educated operator on the proper method of logging drills.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 9 November 2022 Resolved
An adult lifejacket must be provided for each person carried on board. One adult lifejacket was found unserviceable. Repair or replace one adult lifejacket. Vessel reduced to 155 total persons allowed until this is completed. 46 CFR 180.71
Condition: Damaged By Earlier Event
Action required: 705 - Other - as specified
Resolved 10 January 2023
Resolution: Owner replaced the damaged adult Type I lifejacket with a new one and stenciled the vessels name onto the same.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 9 November 2022 Resolved
Engine exhaust pipe installation. Protection must be provided in compliance with § 177.970 of this chapter at such locations where persons or equipment might come in contact with an exhaust pipe. Exhaust lagging iwo the turbo chargers on both MDE's exhaust lagging is worn or missing. 46 CFR 182.430.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 29 November 2022
Resolution: Vessels engineer replaced damgaged exhaust lagging - all sat.
09 - Working and Living Conditions › 092 - Working Conditions › Lighting (Working spaces)
Issued 9 November 2022 Resolved
Lighting fixtures. (a) Each lighting fixture globe, lens, or diffuser must have a guard or be made of high strength material, except in an accommodation space, radio room, galley, or similar space where it is not subject to damage. (b) A lighting fixture may not be used as a connection box for a circuit other than the branch circuit supplying the fixture. (c) A lighting fixture must be installed as follows: (1) Each fixture must comply with § 183.200. (2) Each lighting fixture and lamp holder must be fixed. A fixture must not be supported by the screw shell of a lamp holder. (3) Each pendant type lighting fixture must be suspended by and supplied through a threaded, rigid conduit stem. The light fixture centerline in the engine room is missing the protective globe and light bulbs. Repair or replace light fixture. 46 CFR 183.410
Condition: Damaged By Earlier Event
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 29 November 2022
Resolution: Owners engineer replaced the faulty light fixture with a new one - all sat.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 9 November 2022 Resolved
Cable and wiring requirements. Each connection to a conductor or terminal part of a conductor must be made within an enclosure and have either: (1) A pressure type connector on each conductor; (2) A solder lug on each conductor; (3) A splice made with a pressure type connector to a flexible lead or conductor; or (4) A splice that is soldered, brazed, or welded to a flexible lead or conductor. Wiring under the bridge console and two exterior PA speakers, one aft on the upper deck and one on the stbd side upper deck wire connections are broken and exposed. Properly repair wiring and PA speakers. 46 CFR 183.340.
Condition: Damaged By Earlier Event
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 29 November 2022
Resolution: Owners engineer repaired the faulty wiring - all sat.
01 - Certificates & Documentation › 013 - Documents › Stability Information Booklet
Issued 9 November 2022 Resolved
Stability letter. When, in accordance with § 178.210 of this chapter, a vessel must be provided with a stability letter, the stability letter must be posted under glass or other suitable transparent material, such that all pages are visible, at the operating station of the vessel. If posting is impracticable, the stability letter must be kept on board in a weathertight container readily available for use by the crew and display to passengers and others on request. Properly post vessels stability letter on the bridge. 46 CFR 176.306
Condition: Placed in Improper Service
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 29 November 2022
Resolution: Operator posted a copy of the vessels stability letter on the bridge - all sat.
10 - Safety of Navigation › N/A - No Subsystem › Nautical publications
Issued 9 November 2022 Resolved
Charts and nautical publications. (a) As appropriate for the intended voyage, a vessel must carry adequate and up-to-date: (1) Charts of large enough scale to make safe navigation possible; (2) U.S. Coast Pilot or similar publication; (3) Coast Guard Light List; (4) Tide tables; and (5) Current tables, or a river current publication issued by the U.S. Army Corps of Engineers or a river authority. (b) Extracts from the publications listed above for the areas to be transited may be provided instead of the complete publication. Have onboard updated nautical publications for operating areas vessel has 2021 publications. 46 CFR 184.420
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 29 November 2022
Resolution: Operator placed onboard up to date current tables for vessels op areas - all sat.
01 - Certificates & Documentation › 012 - Crew Certificates › Certificates for master and officers
Issued 9 November 2022 Resolved
Every seaman referred to in this section, when required, must produce a valid MMC or MMD with all applicable rating endorsements for the position sought, a valid TWIC unless the mariner is exempt under 46 CFR 10.203(b)(2), and a valid medical certificate to the master of the vessel at the time of his or her employment before signing Articles of Agreement. Seamen who do not possess one of these credentials may be employed at a foreign port or place within the limitations specified in § 15.720 of this part. The master onboard the vessel at the time of inspection did not have their medical certificate. 46 CFR 15.403
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 29 November 2022
Resolution: Vessels Master provided his medical certificate - all sat.
09 - Working and Living Conditions › 091 - Living Conditions › Medical Equipment
Issued 9 November 2022 Resolved
First-aid kits. A vessel must carry either a first-aid kit approved under approval series 160.041 or a kit with equivalent contents and instructions. For equivalent kits, the contents must be stowed in a suitable, watertight container that is marked “First-Aid Kit”. A first-aid kit must be easily visible and readily available to the crew. First aid kit aspirin was expired. 46 CFR 184.710
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 29 November 2022
Resolution: Operator replaced the expired aspirin - all sat.
11 - Life Saving Appliances › N/A - No Subsystem › Buoyant apparatus
Issued 19 October 2021 Resolved
Per D17 Inst 16714.1A, vessel is required to have 100% IBA capacity for all persons onboard. Vessel operator has sent out vessels outfitting of IBA's and replaced with three 50 person and one 4 person IBA. Total persons allowed onboard is reduced to 154 total persons allowed. IAW 46 CFR 180.25(b).
Condition: Improper Installation
Action required: 701 - Prior to carriage of passengers/cargo
Due 19 November 2021
Resolved 21 October 2021
Resolution: Operator now has IBA capacity onboard for 156 total persons.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 19 October 2021 Resolved
An adult life jacket must be provided for each person carried on board a vessel. Three of the adult type 1 life-preservers were condemned due to poor condition. Total persons allowed reduced to 153 until the damaged adult type 1 PFD's replaced to the satisfaction of the attending CG Marine Inspector. IAW 46 CFR 180.71(a)
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 25 November 2021
Resolved 17 February 2022
Resolution: Owner placed onboard three new Adult Type 1 PFD's with the vessels name stenciled onto the same.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 19 October 2021 Resolved
Vessel is required to have two fixed power bilge pumps. The vessels fire pump which is the second fixed bilge pump was unable to draw bilge suction. Properly repair the fire/bilge pump. IAW 46 CFR 182.520
Condition: Damaged By Earlier Event
Action required: 16 - Rectify deficiencies w/in 14 days
Due 8 November 2021
Resolved 23 May 2022
Resolution: Owner installed new power driven bilge pump op tested - all sat.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 19 October 2021 Resolved
When a flexible fill pipe section is a nonconductor of electricity, the metallic sections of the fill pipe separated thereby must be joined by a conductor for protection against generation of a static charge when filling with fuel. There are no bonding wires connecting the sections of piping were there are sections of flexible hose. IAW 46 CFR 182.445(g)
Condition: Placed in Improper Service
Action required: 16 - Rectify deficiencies w/in 14 days
Due 8 November 2021
Resolved 10 November 2021
Resolution: Bonding wires have been added to fuel fill pipes.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 19 October 2021 Resolved
All machinery and equipment must be installed and maintained in such a manner as to afford adequate protection from causing fire, explosion, machinery failure, and personnel injury. Properly repair hydraulic oil leak on the port stabilizer and clean oil from bilges in the aft steering space. IAW 46 CFR 182.100 & 176.830.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 8 November 2021
Resolved 10 November 2021
Resolution: Leaking hydraulic hose was replaced with a new hose and tested - sat. Hydraulic oil was cleaned fm the bilge.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 10 November 2020 Resolved
Replace expired battery in life ring buoy light outside of bridge wing starboard side.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 29 December 2020
05 - Radio Communications › N/A - No Subsystem › Main installation
Issued 10 November 2020 Resolved
[withheld — contains personal information; the deficiency system, dates, and resolution status are shown above]
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 29 December 2020
03 - Water/Weathertight Conditions › N/A - No Subsystem › Machinery space openings
Issued 10 November 2020 Resolved
Remove old sewage pipe running though the aft bulkhead in the tank room to the Laz. Space
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 21 October 2021
Resolution: Owner removed the sewage pipe and plugged the bulkhead.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Auxiliary engine
Issued 10 November 2020 Resolved
Provide fire sleeve for both generator fuel hoses to meet the requirements of SAE-1942.
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 29 December 2020
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 10 November 2020 Resolved
Provide metal wire support ever 24” for wire runs in engine room
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 29 December 2020
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 10 November 2020 Resolved
Provide proper supports for all pipes and hoses in engine room.
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 29 December 2020
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 10 November 2020 Resolved
Provide bonding for both rudder post.
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 29 December 2020
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 10 November 2020 Resolved
Repair or replace 37 damaged adult and 13 children lifejackets. Vessel has provided 28 adult temporary lifejackets
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 29 December 2020
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 30 October 2019 Resolved
Five of vessel's life jackets were damaged beyond usage. Repair or replace damaged life jackets. Vessel limited tto one hundred fifty one (151) persons on board until life jackets are provide.
Action required: 705 - Other - as specified
Resolved 4 November 2019
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 30 October 2019 Resolved
Two life bouy light's batteries were expired. Renew light batteries prior to night time operations.
Action required: 705 - Other - as specified
Resolved 4 November 2019
07 - Fire Safety › N/A - No Subsystem › Means of escape
Issued 30 October 2019 Resolved
Emergency escape from crew quarters was blocked with miscelleneous gear. Remove gear blocking escape.
Action required: 10 - Deficiency Rectified
Resolved 30 October 2019
10 - Safety of Navigation › N/A - No Subsystem › Other (navigation)
Issued 30 October 2019 Resolved
Navigational charts were out of date and not corrected. Provide updated nav chart.
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 4 November 2019
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 30 October 2019 Resolved
Electrical cable for outlet switch in bow thruster space was improperly spliced. Renew cable or make proper splice in electrical cable.
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 4 November 2019
10 - Safety of Navigation › N/A - No Subsystem › Other (navigation)
Issued 30 October 2019 Resolved
Coast Pilot and Light List were out of date. Provide updated navigational publications.
Action required: 10 - Deficiency Rectified
Resolved 30 October 2019
07 - Fire Safety › N/A - No Subsystem › Fixed fire extinguishing installation
Issued 21 October 2019 Resolved
30 second time delay activated at 41 seconds. Replace time delay and demonstrate system to the satisfaction of the attending CG Marine Inspector. Until such time as time delay is replaced/tested, vessel authorized to operate in accordance with approved contingency plan.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 4 November 2019
Resolved 24 October 2019
Resolution: System was retested satisfactorily by servicing technician.
11 - Life Saving Appliances › N/A - No Subsystem › Inflatable liferafts
Issued 8 October 2019 Resolved
VESSEL’S EIGHT PERSON INFLATABLE BUOYANT APPARATUS WAS REPLACED WITH A SIX PERSON INFLATABLE BUOYANT APPARATUS. VESSEL IS RESTRICTED TO CARRYING ONE HUNDRED FIFTY FOUR (154) PERSONS. LIMITED TO CARRY ONE HUNDRED FORTY EIGHT (148) PASSENGERS WITH EIGHT (8) CREW. WHEN ON A VOYAGE OF LESS THAN 12 HOURS, THE PASSENGERS MAY BE INCREASED TO ONE HUNDRED FIFTY (150) WITH SIX (6) CREW. VESSEL RESTRICTED TO REDUCTION IN PERSONS ON BOARD UNTIL EIGHT PERSON INFLATABLE HAS BEEN REINSTALLED ONBOARD VESSEL AND INSTALLATION HAS BEEN INSPECTED BY THE ATTENDING COAST GUARD MARINE INSPECTOR.
Action required: 705 - Other - as specified
Resolved 29 December 2020
03 - Water/Weathertight Conditions › N/A - No Subsystem › Freeboard marks
Issued 27 September 2018 Resolved
Vessel is required to have either permanent draft marks or permanent loading marks displayed on the hull. Vessel's hull is absent either.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 21 October 2021
Resolution: Owner properly placed draft marks onto the hull iaw vessels stability letter.
Electrical › Lighting (emergency) › Battery Operated Lantern
Issued 23 October 2017 Resolved
Prove proper operation of all emergency lighting.
Action required: 705 - Other - as specified
Due 7 November 2017
Resolved 7 November 2017
Resolution: Witnessed proper operation of all emergency lighting onboard.
Electrical › Electrical Distribution System (service) › Wiring
Issued 23 October 2017 Resolved
Remove dead end wiring for removed wiper motors on main deck fwd. and for old camera system in sewage space.
Action required: 705 - Other - as specified
Due 7 November 2017
Resolved 7 November 2017
Resolution: Verified old wiring and installations had been removed.
Electrical › Electrical Distribution System (service) › Wiring
Issued 23 October 2017 Resolved
Properly wire in heater blower motor on main deck fwd.
Action required: 705 - Other - as specified
Due 7 November 2017
Resolved 7 November 2017
Resolution: Verified heater was properly wired with no exposed wiring.
Lifesaving › Lifebuoys › Self-igniting Lights
Issued 23 October 2017 Resolved
Properly install float water light to lifebuoy.
Action required: 705 - Other - as specified
Due 7 November 2017
Resolved 7 November 2017
Resolution: Verified light was properly attached to the aft ring buoy and functioning.
Navigation › Piloting/Steering › Coast Guard Light List
Issued 23 October 2017 Resolved
Provide updated U.S. Coast Pilot [name withheld] list and Charts for area onboard vessel.
Due 7 November 2017
Resolved 7 November 2017
Resolution: Verified the presence of up to date Charts, Light List, Coast Pilot, Tide and Current Tables for the operating area.
Operations/Management › Drills/Instruction › Fire
Issued 23 October 2017 Resolved
Provide better documentation of man overboard, abandon ship and fire drills to include date of drill and training and general description of drill and training topic covered during next annual inspection.
Action required: 705 - Other - as specified
Due 25 October 2018
Resolved 8 November 2018
Resolution: Verified appropriate log entries made.
Operations/Management › Drills/Instruction › Safety Orientation
Issued 23 October 2017 Resolved
Make passenger safety orientation before getting underway or as soon as practicable every time getting underway.
Action required: 705 - Other - as specified
Due 25 October 2018
Resolved 8 November 2018
Resolution: Verified new passenger safety orientation announcement used before voyages.
Stability › Watertight Integrity › Watertight Subdivision Standard
Issued 30 September 2016 Resolved
All penetrations in a watertight bulkhead must be made watertight. the port main engine aft bulkhead exhaust penetration was identified as not being watertight.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 7 October 2016
Resolved 3 October 2016
Resolution: Penetrations was made watertight via a calking material.
Engineering › Sea-water System (primary cooling) › Piping
Issued 30 September 2016 Resolved
Provide secondary hose clamp securing the stbd main raw water suction nonmetallic hose.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 7 October 2016
Resolved 3 October 2016
Resolution: Verified installation of secondary hose clamp.
Navigation › Piloting/Steering › Binnacle
Issued 15 December 2015 Resolved
Refill binnacle with mineral water for the magnetic compass.
Condition: Invalid
Action required: 705 - Other - as specified
Due 15 December 2015
Resolved 15 December 2015
Resolution: Done
Fire Fighting › Remote Fuel Shutoff › General
Issued 3 December 2015 Resolved
Properly secure the port generator raw water cooling hose out of the way of the port main diesel engine emergecy fuel shut off valve.
Condition: Placed in Improper Service
Action required: 705 - Other - as specified
Due 17 December 2015
Resolved 11 December 2015
Resolution: Done
Electrical › Lighting (emergency) › Battery Operated Lantern
Issued 3 December 2015 Resolved
Properly repair the forward engine room emergency lighting.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 17 December 2015
Resolved 11 December 2015
Resolution: Repaired Sat
Fire Fighting › Means of Escape › Escape Route Signs
Issued 3 December 2015 Resolved
Properly label the engine room emergency exit, EMERGENCY EXIT, KEEP CLEAR minimum of 2"s.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 17 December 2015
Resolved 11 December 2015
Resolution: Done
Communications › Radio Communications › EPIRB
Issued 3 December 2015 Resolved
Renew expired hydrostatic release for the vessels EPIRB.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 17 December 2015
Resolved 11 December 2015
Resolution: Replaced Sat
Deck/Cargo › Holds/Tanks › Hatch Cover
Issued 3 December 2015 Resolved
Properly install missing bolt from the aft lazerette hatch.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 17 December 2015
Resolved 11 December 2015
Resolution: Re-connected
Engineering › Steering Gear System › Rudder Bearing
Issued 3 December 2015 Resolved
Properly maintain/lubricate the steering gear linkage and all moving components.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 17 December 2015
Resolved 11 December 2015
Resolution: Completed, sat
Navigation › Piloting/Steering › Binnacle
Issued 3 December 2015 Resolved
Properly repair / replace the vessels binnacle compass. Compass is low on fluid affecting it from free floating.
Action required: 705 - Other - as specified
Due 15 January 2016
Resolved 8 January 2016
Resolution: Operator replaced the vessels binnacle compass and verified that it is working properly.
Lifesaving › Buoyant Apparatus › Capacity
Issued 2 November 2015 Resolved
Vessel has temporary liferafts onboard while servicing normal rafts. The capacity total of the temporary liferafts is 154. Two persons less than the COI allows on the vessel. The capacity of persons is therefore limited to 154 crew and passengers total. This will remain in effect untill the original rafts are returnedt to the vessel and verified by a marine inspector.
Due 16 November 2015
Resolved 3 December 2015
Resolution: All original IBAs onboard, sat.
Lifesaving › Buoyant Apparatus › Capacity
Issued 9 January 2012 Resolved
Whille vessel is servicing BA's, vessel may not carry more than 150 persons. Vessel is currently fitted with 3 temporary BA's that provide a total capacity of 150 person.
Condition: Invalid
Action required: 705 - Other - as specified
Due 27 January 2012
Resolved 27 January 2012
Resolution: Attended vessel and verified the installation of serviced BA''s.
Construction/Loadline › Hull › Bottom Plating
Issued 29 September 2006 Resolved
Re-glass bolts attachments on bottom plating STBD rudder (4) bolts and Port rudder (1) bolt.
Condition: Unknown
Due 4 October 2006
Resolved 4 October 2006
Resolution: Done, sat.
Construction/Loadline › Markings › Draft Marks/Indicating System
Issued 29 September 2006 Resolved
Re-stenciled draft marks Port & STBD bow.
Condition: Unknown
Due 4 October 2006
Resolved 4 October 2006
Resolution: Done, sat.
Electrical › Mast › Lightning Ground
Issued 29 September 2006 Resolved
Re-attached grounding strap Port rudder stock in the aft lazarette.
Condition: Unknown
Due 4 October 2006
Resolved 4 October 2006
Resolution: Done, sat.
Construction/Loadline › Penetrations › Pipe Flange
Issued 29 September 2006 Resolved
Double clamp discharge valve located Port side in the aft collision bulkhead.
Condition: Unknown
Due 4 October 2006
Resolved 4 October 2006
Resolution: Done, sat.
Construction/Loadline › Penetrations › Gasket
Issued 14 November 2005 Resolved
Found watertight bulkhead penetrations for main engine exhaust no longer formed a complete watertight seal.
Action required: 705 - Other - as specified
Due 5 January 2006
Resolved 23 December 2005
Resolution: Witnessed satisfactory installation of bulkhead sealing rings on port and stbd exhaust tube penetrations forming a watertight seal.
Lifesaving › Inflatable Buoyant Apparatus › Not on Board
Issued 3 November 2005 Resolved
Number of persons on COI is reduced to 135 until CG approved life rafts are re-installed.
Action required: 705 - Other - as specified
Due 24 November 2005
Resolved 5 December 2005
Resolution: Found all IBA''s in place and satisfactorily serviced
Lifesaving › Inflatable Buoyant Apparatus › Weak Link
Issued 25 December 2004 Resolved
Replace the expended weak link in the port IBA retention system.
Action required: 701 - Prior to carriage of passengers/cargo
Due 27 December 2004
Resolved 27 December 2004
Personnel › Certificates/Documents/Licenses › License, Operator
Issued 29 October 2004 Resolved
Obtain an FCC Marine Radio Operator's Permit or higher license for at least one member of the operating crew.
Action required: 705 - Other - as specified
Due 28 February 2005
Resolved 5 December 2005
Resolution: Found Master had current FCC Marine Operator''s Permit.
Engineering › Freshwater System (jacketwater cooling) › Piping
Issued 29 October 2004 Resolved
Repair the coolant leak in piping at the starboard main engine heat exchanger.
Action required: 705 - Other - as specified
Due 29 November 2004
Resolved 22 November 2004
Communications › Radio Communications › EPIRB
Issued 29 October 2004 Resolved
Obtain a current registration decal and affix it to the EPIRB.
Action required: 705 - Other - as specified
Due 29 November 2004
Resolved 29 November 2004
Electrical › Electrical Distribution System (service)
Issued 4 November 2003 Resolved
Install protective covers over all exposed DC wiring blocks and remove or enclose all dead end wires. LEGACY COMPONENT DESC: Junction Box
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 4 December 2003
Resolved 18 November 2003
Resolution: Protective covers installed and dead end wires enclosed.
Engineering › Diesel Engine (auxiliary) › Piping (exhaust)
Issued 4 November 2003 Resolved
Make permanent repairs to all exhaust leaks at next dry dock. LEGACY COMPONENT DESC: Piping (exhaust)
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 24 October 2004
Resolved 21 November 2004
Electrical › Electrical Distribution System (service)
Issued 4 November 2003 Resolved
Install proper dedicated AC outlet for heater under bridge console. LEGACY COMPONENT DESC: Outlet Box
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 4 December 2003
Resolved 18 November 2003
Resolution: Dedicated AC outlet for heater under bridge console installed.
Engineering › Fuel Oil Storage/Transfer System
Issued 17 December 2002 Resolved
Provide fuel oil shut off valves between each auxilliary generator and their respective fuel oil filters. LEGACY COMPONENT DESC: Valve
Condition: Improper Installation
Due 17 January 2003
Resolved 14 January 2003
Resolution: New valves installed.
Documentation › Certificates/Documents › Certificate of Inspection
Issued 17 December 2002 Resolved
Obtain and post a signed Certificate of Inspection prior to sailing with passengers.
Condition: Improper Installation
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 17 January 2003
Resolution: Found in company office; posted prior to completion of inspection.
Engineering › Thrusters
Issued 22 October 2002 Resolved
Effect structural repair to 1/2" deep gouge in lower/starboard interior wall of FRP bow thruster tunnel. LEGACY COMPONENT DESC: Tunnel
Condition: Damaged By Earlier Event
Action required: 17 - Rectify deficiencies prior to departure
Due 15 November 2002
Resolved 24 October 2002
Engineering › Shafting/Propeller Arrangements
Issued 22 October 2002 Resolved
Effect replacement of damaged port propeller. LEGACY COMPONENT DESC: Propeller (fixed pitch)
Condition: Damaged By Earlier Event
Action required: 17 - Rectify deficiencies prior to departure
Due 15 November 2002
Resolved 24 October 2002
Engineering › Diesel Engine (propulsion-reduction gear)
Issued 22 October 2002 Resolved
Replace deteriorated rubber hoses in port and starboard exhaust booster cooling water systems, and securely remount the port booster cooling water pump. LEGACY COMPONENT DESC: Piping (exhaust)
Condition: Improper/Lack of Maintenance
Due 15 November 2002
Resolved 24 October 2002
Fire Fighting
Issued 14 November 2001 Resolved
Effect permanent repairs to the vessel's fire pump. The fire pump must provide 60 psi of pressure at a volume of 50 gallons per minute.
Condition: Unknown
Due 23 November 2001
Resolved 23 November 2001
Fire Fighting
Issued 18 February 2000 Resolved
PROVIDE VAPOR BARRIER TO PROTECT PERMEABLE ACOUSTIC TILE WHICH LINES OVERHEAD OF MACHINERY SPACE PER 46 CFR 177.405(e).
Condition: Unknown
Due 18 February 2000
Resolved 18 February 2000
Lifesaving
Issued 3 December 1999 Resolved
MARINE INSPECTORS TO VERIFY INSTALLATION AND ARRANGEMENT OF SURVIVAL CRAFT UPON RE-INSTALLATION PRIOR TO ANY VOYAGE CARRYING PASSENGERS.
Condition: Unknown
Due 3 December 1999
Resolved 3 December 1999
Lifesaving
Issued 3 December 1999 Resolved
EMERGENCY BROADCAST PLACARD MUST BE INSTALLED NEAR VSL COMMUNICATIONS SYSTEM IN ACCORDANCE WITH 46CFR184.506.
Condition: Unknown
Due 3 December 1999
Resolved 3 December 1999
Fire Fighting
Issued 3 December 1999 Resolved
VESSEL MISSING FIRE DETECTION SYSTEM IN ENGINE SPACE IN ACCORDANCE WITH 46CFR181.400(C)(1). ENGINE ROOM TO BE CONTINUOUSLY MANNED WHILE VESSEL IS UNDERWAY WITH PASSENGERS UNTIL SYSTEM INSTALLED.
Condition: Unknown
Due 3 December 1999
Resolved 3 December 1999
Fire Fighting
Issued 3 December 1999 Resolved
FIXED CO2 SYSTEM OVERDUE FOR ANNUAL SERVICING. TAG ON CANISTERS INDICATE LAST SERVICE WAS IN NOV 1998.
Condition: Unknown
Due 17 December 1999
Resolved 23 December 1999
Documentation
Issued 3 December 1999 Resolved
VESSEL TO SUPPLY PROOF OF CONTRACT WITH DRUG TESTING CONSORTIUM IN ACCORDANCE WITH 46CFR16.230 AND THE ANNUAL DRUG TESTING AUDIT.
Condition: Unknown
Due 17 December 1999
Resolved 23 December 1999
Lifesaving
Issued 31 December 1998 Resolved
REPLACE CURRENT TRASH CANS WITH NON-COMBUSTIBLE TYPE PER 46 CFR 177.405.
Condition: Unknown
Due 31 December 1998
Resolved 31 December 1998
Construction/Loadline
Issued 31 December 1998 Resolved
MODIFY PLASTIC THRU SUBDIVISION PIPING WITH METAL PENETRATION AND FITTINGS PER 46 CFR 182.720.
Condition: Unknown
Due 31 December 1998
Resolved 31 December 1998
Construction/Loadline
Issued 31 December 1998 Resolved
PROVIDE A PUMP ADEQUATE ENOUGH FOR THE FORE-PEAK SPACE.
Condition: Unknown
Due 31 December 1998
Resolved 31 December 1998
Accommodation/Occupational Safety
Issued 31 December 1998 Resolved
PROVIDE SLOPED METALLIC TOP ON ELECTRIC BASE BOARD HEATERS TO PREVENT COMBUSTIBLE ITEMS FROM BEING PLACED ON TOP.
Condition: Unknown
Due 31 December 1998
Resolved 31 December 1998
Lifesaving
Issued 18 November 1998 Resolved
CONDUCT FIRE AND MAN OVERBOARD DRILLS WITH CREW IN THE PRESENCE OF A COAST GUARD MARINE INSPECTOR, PRIOR TO THE CARRIAGE OF PASSENGERS.
Condition: Unknown
Due 18 November 1998
Resolved 18 November 1998
Documentation
Issued 18 November 1998 Resolved
OBTAIN STABILITY LETTER AND POST ONBOARD VESSEL, PRIOR TO THE CARRIAGE OF PASSENGERS.
Condition: Unknown
Due 18 November 1998
Resolved 18 November 1998
Lifesaving
Issued 18 November 1998 Resolved
PROVIDE PROOF OF ENROLLMENT OF CREW IN DRUG TESTING PROGRAM.
Condition: Unknown
Due 18 November 1998
Resolved 18 November 1998
Lifesaving
Issued 18 November 1998 Resolved
PROVIDE FIRST AID KIT IN ACCORDANCE WITH 46 CFR 160.041.
Condition: Unknown
Due 18 November 1998
Resolved 18 November 1998
Documentation
Issued 18 November 1998 Resolved
OBTAIN A DOCUMENTATION CERTIFICATE UNDER CURRENT VESSEL NAME, PRIOR TO THE CARRIAGE OF PASSENGERS.
Condition: Unknown
Due 18 November 1998
Resolved 18 November 1998

Casualty record · 2

5 January 2009Routine · role: Involved in a Marine Casualty · serious marine incident, as classified · 1 injured · activity 3398604
17 November 2012Routine · role: Involved in a Marine Casualty · activity 4489263
Each line is an incident investigation the Coast Guard recorded with this hull among the vessels involved, with the date and the classification the Coast Guard gave it, and the bridge, lock or dam the investigation names where it names one. Involvement is not fault. The investigation narrative is not published. Source: IIR, through 2026.

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.