Records from 2011 to 2026. Most recent: inspection, 5 May 2026.
04 - Emergency Systems › N/A - No Subsystem › Water level indicator
Issued 12 June 2023
Resolved
A visual and audible alarm must be provided at the operating station to indicate a high water level. High level alarm at the bow was not operational.
Action required: 10 - Deficiency Rectified
Resolved 12 June 2023
Resolution: New alarm installed
11 - Life Saving Appliances › N/A - No Subsystem › Inflatable liferafts
Issued 12 June 2023
Resolved
Each survival craft must be secured to the vessel by a painter with a float-free link permanently attached to the vessel and stowed so that when the vessel sinks the survival craft floats free and, if inflatable, inflates automatically.
IBA was not properly installed and the painter was not attached to the vessel.
Action required: 10 - Deficiency Rectified
Resolved 12 June 2023
Resolution: Raft was properly attached to the vessel via the weak-link on the HRU.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Other (load lines)
Issued 11 July 2022
Resolved
The construction and arrangement of a vessel must allow the safe operation of the vessel in accordance with the terms of its Certificate of Inspection giving consideration to provisions for a seaworthy hull.
Holes in water tight deck in front of operation station.
Condition: Damaged By Earlier Event
Action required: 16 - Rectify deficiencies w/in 14 days
Due 25 July 2022
Resolved 14 July 2022
Resolution: O/O fiberglassed the existing holes.
09 - Working and Living Conditions › 091 - Living Conditions › Sanitary Facilities
Issued 11 July 2022
Resolved
at each inspection for certification and at every other vessel inspection, quarters, toilet and washing spaces, galleys, serving pantries, lockers, and similar spaces may be examined to determine that they are serviceable and in a sanitary condition.
MSD ovbd hose was broken and leaking.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 25 July 2022
Resolved 11 August 2022
Resolution: New hoses provided
03 - Water/Weathertight Conditions › N/A - No Subsystem › Manholes/flush scuttles
Issued 11 July 2022
Resolved
A hatch exposed to the weather must be watertight.
Aft hatch & Fwd hatch failed hose test.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 11 August 2022
Resolved 11 August 2022
Resolution: Hatch repaired
09 - Working and Living Conditions › 091 - Living Conditions › Medical Equipment
Issued 11 July 2022
Resolved
A vessel must carry either a first-aid kit approved under approval series 160.041 or a kit with equivalent contents and instructions. For equivalent kits, the contents must be stowed in a suitable, watertight container that is marked “First-Aid Kit”. A first-aid kit must be easily visible and readily available to the crew.
Condition: Invalid
Action required: 50 - Rectify deficiencies w/in 30 days
Due 11 August 2022
Resolved 11 August 2022
Resolution: New first aid kit provided
05 - Radio Communications › N/A - No Subsystem › Satellite EPIRB 406MHz/1.6GHz
Issued 11 July 2022
Resolved
The EPIRB test required by paragraph (a) shall be logged or otherwise documented, as applicable.
EPIRB testing has not been documented.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 11 August 2022
Resolved 11 August 2022
Resolution: Log provided and testing logged
04 - Emergency Systems › N/A - No Subsystem › Abandon ship drills
Issued 11 July 2022
Resolved
Abandon ship and man overboard drills and training shall be logged or otherwise documented for review by the Coast Guard upon request. The drill entry shall include the following information: (1) Date of the drill and training; and (2) General description of the drill scenario and training topics.
Drills not recorded.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 11 August 2022
Resolved 11 August 2022
Resolution: Drills properly logged
04 - Emergency Systems › N/A - No Subsystem › Fire drills
Issued 11 July 2022
Resolved
Fire fighting drills and training shall be logged or otherwise documented for review by the Coast Guard upon request. The drill entry shall include the following information: (1) Date of the drill and training; and (2) General description of the drill scenario and training topics.
Drills not recorded.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 11 August 2022
Resolved 12 August 2022
Resolution: Drills properly logged
10 - Safety of Navigation › N/A - No Subsystem › Lights, shapes, sound-signals
Issued 11 July 2022
Resolved
All vessels must have navigation lights that are in compliance with the applicable sections of the International and Inland Navigation Rules.
Missing Anchor light.
Condition: Design Flaw
Action required: 50 - Rectify deficiencies w/in 30 days
Due 11 August 2022
Resolved 11 August 2022
Resolution: Anchor light working properly
10 - Safety of Navigation › N/A - No Subsystem › Lights, shapes, sound-signals
Issued 11 July 2022
Resolved
A vessel of 12 meters or more in length shall be provided with a whistle.
No whistle is fitted on the vessel.
Condition: Design Flaw
Action required: 50 - Rectify deficiencies w/in 30 days
Due 11 August 2022
Resolved 11 August 2022
Resolution: Sound producing device provided
11 - Life Saving Appliances › N/A - No Subsystem › Inflatable liferafts
Issued 11 July 2022
Resolved
Every vessel equipped with an inflatable survival craft must have approved placards or other cards containing instructions for launching and inflating inflatable survival craft for the information of persons on board posted in conspicuous places by each inflatable survival craft.
Missing launching instructions.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 11 August 2022
Resolved 11 August 2022
Resolution: Instructions posted at the liferaft station
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 11 July 2022
Resolved
The following spaces must be equipped with a fixed gas fire extinguishing system, in compliance with § 181.410, or other fixed fire extinguishing system specifically approved by the Commandant, except as otherwise allowed by paragraph (b) of this section: (1) A space containing propulsion machinery;
Holes on port and stbd engine room vents.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 11 August 2022
Resolved 11 August 2022
Resolution: Holes sealed
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 11 July 2022
Resolved
on a vessel carrying only one ring buoy, must be attached to the lanyard with a corrosion-resistant clip. The clip must have a strength of at least 22.7 kilograms (50 pounds).
life Line needs corrosion-resistant clip.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 11 August 2022
Resolved 11 August 2022
Resolution: new clip provided
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 11 July 2022
Resolved
An adult life jacket must be provided for each person carried on board a vessel. (b) In addition, a number of child size life jackets equal to at least 10% of the number of persons permitted on board must be provided, or such greater number as necessary to provide a life jacket for each person being carried that is smaller than the lower size limit of the adult life jackets provided to meet this section.
3 adult life jackets and 1 child life jacket was wasted and serviceable. Reduced to the number of appropriate life jackets on board.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Resolved 14 July 2022
Resolution: O/O placed new life jackets in service.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 11 July 2022
Resolved
Each floating waterlight must be approved in accordance with § 161.010 in subchapter Q of this chapter.
Water light battery was expired but replaced on the spot.
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Resolved 11 July 2022
Resolution: Replaced battery
02 - Structural Conditions › N/A - No Subsystem › Steering gear
Issued 11 July 2022
Resolved
A vessel must be provided with a main steering gear that is: (1) Of adequate strength and capable of steering the vessel at all service speeds.
Steering ram mounting lags pulled from mounting point. O/O drilled through mounting point and through bolted it. Conducted satisfactory test.
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Resolved 11 July 2022
Resolution: O/O drilled through mounting point and through bolted it. Conducted satisfactory test.
02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 17 February 2022
Resolved
A penetration in a watertight bulkhead must be as high and as far inboard as practicable and made watertight; properly seal the drain hole in the bottom of the forward bulkhead in the #1 void/ battery compartment.
Action required: 705 - Other - as specified
Resolved 4 March 2022
02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 17 February 2022
Resolved
The number of penetrations in a watertight bulkhead must be minimized. A penetration in a watertight bulkhead must be as high and as far inboard as practicable and made watertight; re-route the discharge hose from the engine compartment bilge pump so as not to penetrate the forward bulkhead in the #1 void and properly seal the existing hole in the bulkhead.
Action required: 705 - Other - as specified
Resolved 4 March 2022
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 17 February 2022
Resolved
Install a bushing in the steering system tiller arm connection to the hydraulic ram so as to remove excess play.
Action required: 705 - Other - as specified
Resolved 4 March 2022
10 - Safety of Navigation › N/A - No Subsystem › Charts
Issued 1 June 2021
Resolved
Vessel required to carry current/up to date charts for areas transited. Vessel was not equipped with charts of the AICW (#11534).
Action required: 16 - Rectify deficiencies w/in 14 days
Due 15 June 2021
Resolved 19 July 2021
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 1 June 2021
Resolved
Vessels portable fire extinguishers are required to be stowed to the satisfaction of the [name withheld] brackets for portable fire extinguishers are wasted/missing/broken.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 1 July 2021
Resolved 19 July 2021
10 - Safety of Navigation › N/A - No Subsystem › Navigation bridge visibility
Issued 1 June 2021
Resolved
Vessels windows and other openings at the operating station must be of sufficient size and properly located to provide an adequate view for safe navigation in all operating conditions. Existing port side cabin sliding glass window was fractured.
Condition: Damaged By Earlier Event
Action required: 16 - Rectify deficiencies w/in 14 days
Due 15 June 2021
Resolved 19 July 2021
03 - Water/Weathertight Conditions › N/A - No Subsystem › Machinery space openings
Issued 1 June 2021
Resolved
All penetrations in a watertight bulkhead shall located as high/inboard as practicable. Existing bulkhead penetrations in way of forward watertight bulkhead in the battery compartment were not properly sealed.
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 1 July 2021
Resolved 19 July 2021
07 - Fire Safety › N/A - No Subsystem › Ventilation
Issued 1 June 2021
Resolved
Vessel required to be equipped with ventilation closure devices for machinery space. The starboard ventilation closure device is not capable of being fully closed due to the port fuel tank vent routing (obstruction).
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 1 July 2021
Resolved 19 July 2021
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 1 June 2021
Resolved
Vessel required to be fitted with rail courses IWO passenger accomodation spaces. Aft rail course is missing securing hardware.
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 15 June 2021
Resolved 19 July 2021
11 - Life Saving Appliances › N/A - No Subsystem › Distress flares
Issued 14 July 2020
Resolved
Vessel required to be equipped with proper type & quantity of visual distress flares for route. Vessel's existing visual distress signals were found expired.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 14 July 2020
Resolution: Attending Inspector(s) verified vessel was outfitted with proper type/qty of visual distress signals.
10 - Safety of Navigation › N/A - No Subsystem › Charts
Issued 14 July 2020
Resolved
Vessel required to carry current/up to date marine charts for areas transited. Vessels existing marine chart was damaged/outdated.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 28 July 2020
Resolved 26 August 2020
Resolution: Attending Inspector(s) verified carriage of current/up to date marine charts for areas transited.
09 - Working and Living Conditions › 091 - Living Conditions › Medical Equipment
Issued 14 July 2020
Resolved
Vessel required to be outfitted with a suitable first aid kit for vessels service. Existing first aid kit required updating/replacement of (missing) items.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 28 July 2020
Resolved 26 August 2020
Resolution: Attending Inspector(s) verified renewal/replacement of first aid kit.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 14 July 2020
Resolved
Vessels ring life buoy is required to be equipped with a serviceable floating water light. Existing floating water light battery requires replacement.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 28 July 2020
Resolved 26 August 2020
Resolution: Attending Inspector(s) verified renewal of battery IWO floating waterlight battery.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 14 July 2020
Resolved
Vessels PFD stowage locations are required to be marked with type/qty of PFD's. Existing markings are worn/peeling, requires replacement.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 28 July 2020
Resolved 26 August 2020
Resolution: Attending Inspector(s) verified renewal of PFD markings.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 14 July 2020
Resolved
Vessel required to be fitted with two portable lights. Vessel is missing the required two portable lights.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 28 July 2020
Resolved 26 August 2020
Resolution: Attending Inspector(s) verified carriage of two portable lights.
14 - Pollution Prevention › 144 - MARPOL Annex IV (Not Applicable to PSC Exams conducted in the U.S.) › Sewage treatment plant
Issued 14 July 2020
Resolved
Vessels marine sanitation device is required to fitted with operating instructions. Existing marine sanitation device is not equipped with operating instructions.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 28 July 2020
Resolved 26 August 2020
Resolution: Attending Inspector(s) verified posting of MSD operating instructions.
02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 14 July 2020
Resolved
Vessel required to undergo inspection to ensure the vessel is in satisfactory condition, fit for service intended and complies with all applicable regulations. Vessels main deck has "soft spots" in way of emergency fuel shut-off valve hatches. Repairs to be effected NLT next scheduled drydock inspection.
Action required: 705 - Other - as specified
Resolved 4 March 2022
02 - Structural Conditions › N/A - No Subsystem › Bulkheads - cracking
Issued 14 July 2020
Resolved
Vessel required to undergo inspection to ensure the vessel is in satisfactory condition, fit for service intended and complies with all applicable regulations. Vessels non-tight bulkhead IWO head is fractured/unsecured. Temporary repairs are authorized until vessels next scheduled drydock inspection.
Action required: 705 - Other - as specified
Resolved 4 March 2022
02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 3 March 2020
Resolved
Vessel is required to be equipped with a fire extinguishing system for the machinery space/engine room. Vessels pre-engineered fire extinguishing system (FIREBOY) required annual servicing.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 26 May 2020
Resolution: Attending Inspector(s) verified servicing of pre-engineered fire extinguishing system.
08 - Alarms › N/A - No Subsystem › Other (alarms)
Issued 3 March 2020
Resolved
Vessel required to be fitted with high water alarms. Vessels high water alarm IWO lazarette was found damaged/unsecured/laying in bilge.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 26 May 2020
Resolution: Attending Inspector(s) verified repairs to bilge high water alarm.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 3 March 2020
Resolved
Installed fuel filter assembly requires the installation of a flame impingiment bowl. Vessel's installed fuel strainer is not equipped with flame impingiment bowl assembly.
Condition: Improper Installation
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 26 May 2020
Resolution: Attending Inspector(s) verified installation of flame impingiment bowl assembly for Racor fuel filters.
02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 3 March 2020
Resolved
Fractured/delamination of FRP IWO transverse stringers IWO machinery space (stbd side) to transom (along centerline).
Action required: 50 - Rectify deficiencies w/in 30 days
Due 3 April 2020
Resolved 1 June 2021
02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 3 March 2020
Resolved
Delamination of FRP IWO stbd/inboard stringer in battery compartment.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 3 April 2020
Resolved 26 May 2020
Resolution: Attending Inspector(s) verified repairs made IWO stbd/inboard stringer.
10 - Safety of Navigation › N/A - No Subsystem › Nautical publications
Issued 18 April 2019
Resolved
Vessel required to carry current/up to date navigational publications for areas transited. Vessels Coast Pilot [name withheld], Current Tables and USCG Light List were outdated for areas transited.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 18 May 2019
Resolved 16 July 2019
Resolution: Attending Inspector(s) verified the carriage of current/up to date navigational publications.
05 - Radio Communications › N/A - No Subsystem › VHF radio installation
Issued 18 April 2019
Resolved
Vessels VHF-FM radio-telephone is required to be programmed with MMSI ID # for DSC equipped units. Vessels VHF-FM radio-telephones are not properly programmed with MMSI ID#.
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 18 May 2019
Resolved 16 July 2019
Resolution: Attending Inspector(s) verified programming of VHF-FM radio-telephone with MMSI #.
05 - Radio Communications › N/A - No Subsystem › Other (radio communication)
Issued 18 April 2019
Resolved
Vessel required to posess a FCC Safety Radio-Telephony Certificate for communications equipment installed on board. Vessels current FCC Safety Radio-telephony Certificate has expired.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 18 May 2019
Resolved 16 July 2019
Resolution: Attending Inspector(s) verified renewal of FCC Radio Safety Telephony Certificate.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 18 April 2019
Resolved
Vessel required to have a positive shut off valve installed at the hull penetration for bilge piping systems. The stop valve installed in way of fwd machinery space electric submersible bilge pump, starboard side (under helm) was found inoperable/frozen.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 18 May 2019
Resolved 16 July 2019
Resolution: Attending Inspector(s) verified servicing/operation of ball/stop valve.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 18 April 2019
Resolved
Flexible hose connections are authorized for use in vital/non-vital systems. The flexible hose connection between the main engine turbo and fiberglass exhaust piping was found delaminated (outer jacket/inner jacket) and required replacement.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 18 May 2019
Resolved 30 September 2019
Resolution: Attending Inspector verified renewal of flexible hose piping.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 18 April 2019
Resolved
Flexible hose connections are authorized for use in vital/non-vital systems. Attending Inspector called out several raw water leaks in/around the fiberglass exhaust piping for the main diesel engine.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 18 May 2019
Resolved 30 September 2019
Resolution: Attending Inspector verified renewal of FRP exhaust piping (throughout).
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 17 July 2018
Resolved
Batteries in lifesaving appliances are required to be changed annually. The batteries found in the vessels floating waterlights (ring buoy & life float) had not been serviced/changed within the annual requirements.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 17 August 2018
Resolved 6 November 2018
Resolution: Attending Inspector(s) verified renewal of batteries IWO floating water lights.
11 - Life Saving Appliances › N/A - No Subsystem › Buoyant apparatus
Issued 17 July 2018
Resolved
Vessels route requires the carriage of one 22 person life float. Existing life float was noted as being beyond its service life/serviceability and requires replacement.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 17 August 2018
Resolved 11 March 2019
Resolution: Attending Inspector verified installation of a (new) 25-person IBA.
14 - Pollution Prevention › 144 - MARPOL Annex IV (Not Applicable to PSC Exams conducted in the U.S.) › Other (MARPOL Annex IV)
Issued 17 July 2018
Resolved
Operating instructions are required to be posted on board vessel for Type III MSD systems. Attending Inspector(s) noted no instructions were posted.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 17 August 2018
Resolved 6 November 2018
Resolution: Attending Inspector(s) verified installation/posting of operating instructions for Type III MSD (system).
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 17 July 2018
Resolved
Emergency fuel shut-off valves are required to be marked properly with identification & operating instructions. Vessels emergency fuel shut-off valves were not properly marked.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 17 August 2018
Resolved 6 November 2018
Resolution: Attending Inspector(s) verified renewal of emergency fuel shut off markings/operating instructions.
05 - Radio Communications › N/A - No Subsystem › MF/HF Radio installation
Issued 17 July 2018
Resolved
Vessel's route requires the vessel to carry an operable Single Side Band (SSB) radiotelephone. Vessel does not carry an operable Single Side Band (SSB) radiotelephony. In lieu of the required SSB, the vessel carries a satellite phone. The satellite phone installation does not contain the required base station/cradle or external antenna.
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 17 August 2018
Resolved 6 November 2018
Resolution: Attending Inspector(s) verified installation of base station/external antenna for satellite phone installation.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 17 July 2018
Resolved
Vessels is required to be fitted with a steering system suitable for the service intended. Vessels hydraulic steering hose was found with a blister/bubble near the end fitting @ hydraulic ram.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 17 August 2018
Resolved 6 November 2018
Resolution: Attending Inspector(s) verified renewal/replacement of hydraulic steering hose IWO lazarette.
07 - Fire Safety › N/A - No Subsystem › Ventilation
Issued 17 July 2018
Resolved
Vessel is required to have installed ventilation closures, properly installed/marked, for spaces protected by a fixed/pre-engineered fire suppression system. Vessels ventilation closures are not properly identified/marked.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 17 August 2018
Resolved 6 November 2018
Resolution: Attending Inspector(s) verified markings for ventilation closure devices.
05 - Radio Communications › N/A - No Subsystem › VHF radio installation
Issued 17 July 2018
Resolved
Vessels VHF-FM radiotelephone is required to be installed on board and properly programmed with MMSI #. Vessels has two VHF-FM marine radiotelephones installed, neither of which are properly programmed to meet the DSC requirement.
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 17 August 2018
Resolved 6 November 2018
Resolution: Attending Inspector(s) verified programming of MMSI # in VHF-FM radiotelephones.
07 - Fire Safety › N/A - No Subsystem › Fixed fire extinguishing installation
Issued 17 July 2018
Resolved
Vessel is required to be fitted with a fixed fire suppression system/pre-engineered fire suppression system. Vessels installed pre-engineered fire suppression system (bottle) was found in need of repair/servicing due to corrosion/rust.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 17 August 2018
Resolved 6 November 2018
Resolution: Attending Inspector(s) verified installation/renewal of pre-engineered fire suppression system/bottle IWO machinery space.
Engineering › Sea-water System (primary cooling) › Valve
Issued 14 March 2018
Resolved
Through hull valve for raw water wash down pump required replacement.
Action required: 705 - Other - as specified
Due 14 April 2018
Resolved 21 March 2018
Resolution: Attending Inspector(s) verified that the existing valve was properly capped off. Owner/operator intends to utilize an existing thru-hull valve for supplying the raw water wash down pump.
Engineering › Shafting/Propeller Arrangements › Bearing
Issued 14 March 2018
Resolved
Worn water lubricated bearing (cutlass) IWO shaft log.
Action required: 705 - Other - as specified
Due 14 April 2018
Resolved 21 March 2018
Resolution: Attending Inspector(s) verified installation of (new) water lubricated bearing IWO shaft log.
Engineering › Bilge Water Management System › Pump
Issued 14 March 2018
Resolved
Electrical submersible bilge pump wiring IWO lazarette was found disconnected.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Resolved 9 April 2018
Resolution: Attending Inspector(s) verified repairs made to electric submerisble bilge pump IWO lazarette and performed operational test.
Communications › Alarms/Indicators › High Water Alarm
Issued 14 March 2018
Resolved
Vessel not equipped with bilge high water alarms IWO lazarette.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 9 April 2018
Resolution: Attending Inspector(s) verified the installation of bilge high water alarm IWO lazarette and performed operational test.
Engineering › Bilge Water Management System › Valve
Issued 14 March 2018
Resolved
Attending Inspector(s) noted that the thru-hull valve IWO transom for electric submersible bilge pump discharge hose was seized.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 9 April 2018
Resolution: Attending Inspector(s) verified installation/replacement of electric submersible bilge pump thru-hull valve IWO lazarette.
Pollution Prevention/Response › Prevention Equipment › Marine Sanitation Device, Type III
Issued 14 March 2018
Resolved
Attending Inspector(s) noted that the overboard discharge valve for the Type III MSD was seized and the handle was wasted to the point of failure.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 14 April 2018
Resolved 9 April 2018
Resolution: Attending Inspector(s) verified installation/replacement of MSD discharge thru-hull valve.
Construction/Loadline › Hull › Transverse Frame
Issued 14 March 2018
Resolved
Attending Inspector(s) called out rotted transverse frame IWO machinery space (fwd of main engine).
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 9 April 2018
Resolution: Attending Inspector(s) verified repairs made IWO transverse framing in fwd machinery space.
Construction/Loadline › Hull › Longitudinal Frame
Issued 14 March 2018
Resolved
Attending Inspector(s) called out fractured FRP IWO starboard longitudinal frames (where intersects with transverse framing) IWO starboard machinery space.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 9 April 2018
Resolution: Attending Inspector(s) verified repairs made IWO fractured FRP in machinery space (stbd side).
Electrical › Electrical Distribution System (service) › Wiring
Issued 14 March 2018
Resolved
Attending Inspector(s) called out dead ended wiring IWO starboard machinery space (beneath main deck).
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 14 April 2018
Resolved 9 April 2018
Resolution: Attending Inspector(s) verified removal of dead ended wiring IWO starboard machinery space (beneath main deck).
Engineering › Diesel Engine (propulsion-reduction gear) › Piping (exhaust)
Issued 14 March 2018
Resolved
Attending Inspector(s) called out detiorated/rotted flexible hose IWO vessels primary exhaust piping between muffler and transom.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 9 April 2018
Resolution: Attending Inspector(s) verified replacement of flexible exhaust piping between muffler and transom, starboard lazarette.
Engineering › Fuel Oil Storage/Transfer System › Hose
Issued 14 March 2018
Resolved
Attending Inspector(s) called out deteriorated/rotted fuel fill flexible hose IWO port & starboard fuel fill connections.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 14 April 2018
Resolved 9 April 2018
Resolution: Attending Inspector(s) verified repairs made to port & starboard fuel fill(s).
Stability › Watertight Integrity › General
Issued 14 March 2018
Resolved
Attending Inspector(s) called out "open" bulkhead penetrations IWO starboard watertight bulkhead between machinery space/rod room.
Action required: 705 - Other - as specified
Due 14 April 2018
Resolved 9 April 2018
Resolution: Attending Inspector(s) verified that all bulkhead penetrations were properly sealed IWO machinery space/rod room bulkhead.
Construction/Loadline › Structures › Deck Plating
Issued 14 March 2018
Resolved
Attending Inspector(s) called out fractured FRP IWO main deck/side shell in lower rod room, port side.
Action required: 705 - Other - as specified
Due 14 April 2018
Resolved 9 April 2018
Resolution: Attending Inspector(s) witnessed removal of FRP IWO fwd rod room at main deck. No fractures were noted in laminate.
Electrical › Electric Supply System (service) › Battery Installation
Issued 14 March 2018
Resolved
Attending Inspector(s) called out fractured battery box support frame IWO port machinery space.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 14 April 2018
Resolved 9 April 2018
Resolution: Attending Inspector(s) verified repairs made IWO port battery box supports (machinery space).
Engineering › Diesel Engine (propulsion-reduction gear) › Piping (exhaust)
Issued 14 March 2018
Resolved
Attending Inspector(s) noted that the vessels exhaust piping was not equipped with backflow preventers IAW 46 CFR 182.430(c).
Action required: 705 - Other - as specified
Due 14 April 2018
Resolved 6 July 2018
Resolution: Attending Inspector(s) received notification from the owner/operator of subject vessel advising that the exhaust flap has been installed.
Operations/Management › Drug and Alcohol Testing › EAP Display Requirements
Issued 5 June 2017
Resolved
Vessel did not have an established EAP (program)/not displayed on board vessel.
Action required: 705 - Other - as specified
Due 5 July 2017
Resolved 24 July 2017
Communications › Radio Communications › EPIRB
Issued 5 June 2017
Resolved
Hydro-static release for EPIRB was found expired (MAY 2017).
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 5 July 2017
Resolved 24 July 2017
Resolution: Attending Inspector verified installation of new hydro-static release for EPIRB.
Lifesaving › Lifefloat › Float-free Link
Issued 5 June 2017
Resolved
Weak link for life float was undersized.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 5 July 2017
Resolved 24 July 2017
Resolution: Attending Inspector verified installation of new weak link for life float installation.
Navigation › Piloting/Steering › Marine Charts
Issued 5 June 2017
Resolved
Vessel did not carry current/up to date marine charts/navigational publications for areas transited.
Action required: 705 - Other - as specified
Due 5 July 2017
Resolved 24 July 2017
Accommodation/Occupational Safety › Medical/First Aid › Medicine Chest
Issued 5 June 2017
Resolved
Expired items found in first aid kit.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 5 July 2017
Resolved 24 July 2017
Resolution: Attending Inspector verified replacement of expired items in first aid kit.
Communications › Alarms/Indicators › Bilge Alarm
Issued 5 June 2017
Resolved
Bilge high water alarms were not properly marked for spaces served.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 5 July 2017
Resolved 24 July 2017
Resolution: Attending Inspector verified markings for each bilge high water alarms.
Fire Fighting › Ventilation Systems › Duct Hatches
Issued 5 June 2017
Resolved
Ventilation closures for machinery space were not vapor tight.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 5 July 2017
Resolved 24 July 2017
Resolution: Attending Inspector verified modifications made to vessels ventilation closure device for machinery space.
Navigation › Collision/Grounding Avoidance › Navigation Lights
Issued 5 June 2017
Resolved
Vessel not equipped with a stern lights (NAV RULES).
Action required: 705 - Other - as specified
Due 5 July 2017
Resolved 24 July 2017
Resolution: Attending Inspector verified installation and operation of stern light.
Construction/Loadline › Penetrations › Valve Flange
Issued 5 June 2017
Resolved
Thru-hull fittings in way of machinery space were not properly installed (capped over to prevent ingress of water).
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 5 July 2017
Resolved 24 July 2017
Resolution: Attending Inspector verified installation of thru-hull fittings in way of machinery space (capped off).
Engineering › Sea-water System (primary cooling) › Piping
Issued 5 June 2017
Resolved
Raw water intake/cooling hose between the thru-hull valve and main engine water pump was deteriorated/cracked.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 5 July 2017
Resolved 24 July 2017
Resolution: Attending Inspector verified replacement of flexible hose between main engine and sea chest/sea strainer.
Engineering › Steering Gear System › Rudder Stock
Issued 5 June 2017
Resolved
Tiller arm for primary steering system had excessive play where connected to hydraulic actuator.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 5 July 2017
Resolved 24 July 2017
Resolution: Attending Inspector verified adjustments made to vessels steering system.
Communications › Audible Communications › Horn/Whistle
Issued 25 April 2016
Resolved
Condition: Placed in Improper Service
Action required: 705 - Other - as specified
Due 25 May 2016
Resolved 8 June 2016
Accommodation/Occupational Safety › Medical/First Aid › Medicine Chest
Issued 25 April 2016
Resolved
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 25 May 2016
Resolved 8 June 2016
Navigation › Piloting/Steering › Coast Guard Light List
Issued 25 April 2016
Resolved
Condition: Invalid
Action required: 705 - Other - as specified
Due 24 May 2016
Resolved 8 June 2016
Engineering › Lubricating Oil Service System › Gauge
Issued 25 April 2016
Resolved
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 25 May 2016
Resolved 8 June 2016