Passenger (Inspected) · Passenger Ship class · Built 1980s · USCG Southeast District (CGD-SE) · Other hulls named THE LONG LINE
THE LONG LINE is a 1984 passenger vessel (inspected). The Coast Guard has recorded 36 inspections since 1998, most recently in May 2026, along with 105 deficiencies and 1 casualty investigation in 2011.
Records from 1998 to 2026. Most recent: inspection, 5 May 2026.
- Built
- 1984
- Last inspected
- 5 May 2026
- Documentation
- Valid · documentation file of 10 September 2026
- Deficiencies
- 105 recorded · 0 without a recorded resolution
- Controls
- None recorded without a removal date
- Casualties
- 1 investigation · 2011
Identity
1208932
WDH4495
479163
Flag
UNITED STATES
366943440, 367618330
Maury page id
psix-479163
Inspections, by type
The 36 inspections in the strip above, split by the kind of activity the US
Coast Guard recorded. Years with a record are calendar years in which a record exists, not
years in service. What Maury does not do.
Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Passenger Ship class in Maury's sources begin in 1977.
Documentation record
Registered dimensions (L × B × D)44.3 ft × 15.0 ft × 8.0 ft
Registered tonnagegross 35 / net 28
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
BuilderTORRES BOAT MFG., INC · KEY WEST, FL, UNITED STATES · built 1984
Hull materialFRP (Fiberglass)
PropulsionDiesel Reduction
Hull shapeShip
Hull configurationMonohull
Hailing portLITTLE RIVER, SC
Trade endorsementsCoastwise, unrestricted, Fishery
DocumentationValid · issued 7 October 2025 · expires 31 October 2026
Service, as the file records itPassenger (Inspected)
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it28 - Simplified, Net Ton
35 - Simplified, Gross Ton
35 - Simplified, Gross Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 September 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.
Radio station licence
EX336MMSI 367618330 · active · exemption · granted 2 July 2025, expires 2 July 2029
WDH4495MMSI 367618330 · active · compulsorily equipped · granted 20 May 2024, expires 30 April 2034
WDE9178MMSI 366943440 · active · compulsorily equipped · granted 9 April 2019, expires 11 June 2029 · licensed under a name not among this hull’s recorded names (not shown)
WDK6322MMSI 368073430 · cancelled · compulsorily equipped · granted 4 February 2019, cancelled 30 May 2024
FCC Universal Licensing System ship-station file of 6 September 2026, matched to this hull on its
US Official Number. Status and dates are the file’s own. The licensee is not read from the file and is not shown.
A lapsed licence’s MMSI is still the number the vessel transmitted under while it was valid.
Inspection history · 36
5 May 2026
Annual Inspection
Physical examination · Detached Duty Office Myrtle Beach · USCG Southeast District (CGD-SE) · Activity 8367411
11 February 2026
Drydock Exam
Physical examination · Detached Duty Office Myrtle Beach · USCG Southeast District (CGD-SE) · Activity 8310193
16 April 2025
Annual Inspection
Physical examination · Detached Duty Office Myrtle Beach · USCG Southeast District (CGD-SE) · Activity 8112879
5 April 2024
COI Inspection
Physical examination · Detached Duty Office Myrtle Beach · USCG Southeast District (CGD-SE) · Activity 7888803
2 February 2024
Drydock Exam · Deficiency Check
Physical examination · Detached Duty Office Myrtle Beach · USCG Southeast District (CGD-SE) · Activity 7859766
12 June 2023
Annual Inspection
Physical examination · Detached Duty Office Myrtle Beach · USCG Southeast District (CGD-SE) · Activity 7713531
11 August 2022
Deficiency Check
Physical examination · Detached Duty Office Myrtle Beach · USCG Southeast District (CGD-SE) · Activity 7531443
24 June 2022
Administrative Inspection · Deficiency Check · Annual Inspection · DAPI Audit · Examination of Repairs
Physical examination · Sector Charleston · USCG Southeast District (CGD-SE) · Activity 7485808
17 February 2022
Hull Examination · Internal Structural Exam · Examination of Repairs
Physical examination · Sector North Carolina · USCG East District (CGD-E) · Activity 7397647
19 July 2021
Examination of Repairs · Deficiency Check
Physical examination · Detached Duty Office Myrtle Beach · USCG Southeast District (CGD-SE) · Activity 7261816
1 June 2021
Annual Inspection
Physical examination · Detached Duty Office Myrtle Beach · USCG Southeast District (CGD-SE) · Activity 7185508
14 July 2020
Deficiency Check · Annual Inspection · DAPI Audit · Examination of Repairs
Physical examination · Detached Duty Office Myrtle Beach · USCG Southeast District (CGD-SE) · Activity 6998114
3 March 2020
Deficiency Check · Drydock Exam · Internal Structural Exam · Examination of Repairs · Hull Examination
Physical examination · Detached Duty Office Myrtle Beach · USCG Southeast District (CGD-SE) · Activity 6915098
16 February 2020
Type not recorded
No type recorded · USCGC NATHAN BRUCKENTHAL (WPC-1128) · USCG East District (CGD-E) · Activity 6915324
30 September 2019
Examination of Repairs · Deficiency Check
Physical examination · Detached Duty Office Myrtle Beach · USCG Southeast District (CGD-SE) · Activity 6889820
18 June 2019
Type not recorded
No type recorded · USCGC CORMORANT (WPB 87313) · USCG Southeast District (CGD-SE) · Activity 6721291
18 April 2019
DAPI Audit · Examination of Repairs · Deficiency Check · COI Inspection
Physical examination · Detached Duty Office Myrtle Beach · USCG Southeast District (CGD-SE) · Activity 6661226
14 February 2019
Type not recorded
No type recorded · Station Georgetown · USCG Southeast District (CGD-SE) · Activity 6626691
17 July 2018
Deficiency Check · Annual Inspection · DAPI Audit
Physical examination · Detached Duty Office Myrtle Beach · USCG Southeast District (CGD-SE) · Activity 6467322
4 July 2018
Type not recorded
No type recorded · USCGC RICHARD SNYDER (WPC 1127) · USCG East District (CGD-E) · Activity 6478980
14 March 2018
Examination of Repairs · Internal Structural Exam · Deficiency Check · Hull Examination · Drydock Exam
Physical examination · Detached Duty Office Myrtle Beach · USCG Southeast District (CGD-SE) · Activity 6368937
22 February 2018
Type not recorded
No type recorded · USCGC CORMORANT (WPB 87313) · USCG Southeast District (CGD-SE) · Activity 6360435
5 June 2017
Deficiency Check · Administrative Inspection · Annual Inspection · DAPI Audit
Physical examination · Detached Duty Office Myrtle Beach · USCG Southeast District (CGD-SE) · Activity 6168226
8 May 2017
Examination of Repairs · Plan Review "T" Boat
Physical examination · Detached Duty Office Myrtle Beach · USCG Southeast District (CGD-SE) · Activity 6142202
25 April 2016
Annual Inspection · Administrative Inspection · DAPI Audit
Physical examination · Detached Duty Office Myrtle Beach · USCG Southeast District (CGD-SE) · Activity 5862045
30 March 2016
Administrative Inspection · Hull Examination
Physical examination · Detached Duty Office Myrtle Beach · USCG Southeast District (CGD-SE) · Activity 5843568
13 January 2016
Type not recorded
No type recorded · Station Oak Island · USCG East District (CGD-E) · Activity 5796798
17 July 2015
Type not recorded
No type recorded · Sector Charleston · USCG Southeast District (CGD-SE) · Activity 5207412
7 February 2011
Construction Oversight · Examination of Repairs · Administrative Inspection · Plan Review "T" Boat
Physical examination · Marine Safety Unit Wilmington · USCG East District (CGD-E) · Activity 3982576
5 October 2010
Annual Inspection · Deficiency Check
Physical examination · Marine Safety Unit Wilmington · USCG East District (CGD-E) · Activity 3863997
23 February 2010
Drydock Exam · Deficiency Check
Physical examination · Detached Duty Office Myrtle Beach · USCG Southeast District (CGD-SE) · Activity 3686246
22 July 2009
Deficiency Check · Internal Structural Exam · Hull Examination
Physical examination · Marine Safety Unit Wilmington · USCG East District (CGD-E) · Activity 3542693
7 July 2008
Initial Certification
Physical examination · Detached Duty Office Myrtle Beach · USCG Southeast District (CGD-SE) · Activity 3261259
29 May 2008
Simplified Stability Test
Physical examination · Detached Duty Office Myrtle Beach · USCG Southeast District (CGD-SE) · Activity 3221212
14 August 1998
Uninspected Other
Physical examination · MSO WILMINGTON · USCG East District (CGD-E) · Activity 1132048
8 July 1998
Uninspected Other
Physical examination · MSO WILMINGTON · USCG East District (CGD-E) · Activity 1128127
Deficiency record · 105
04 - Emergency Systems › N/A - No Subsystem › Water level indicator
Issued 12 June 2023
Resolved
A visual and audible alarm must be provided at the operating station to indicate a high water level. High level alarm at the bow was not operational.
11 - Life Saving Appliances › N/A - No Subsystem › Inflatable liferafts
Issued 12 June 2023
Resolved
Each survival craft must be secured to the vessel by a painter with a float-free link permanently attached to the vessel and stowed so that when the vessel sinks the survival craft floats free and, if inflatable, inflates automatically.
IBA was not properly installed and the painter was not attached to the vessel.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Other (load lines)
Issued 11 July 2022
Resolved
The construction and arrangement of a vessel must allow the safe operation of the vessel in accordance with the terms of its Certificate of Inspection giving consideration to provisions for a seaworthy hull.
Holes in water tight deck in front of operation station.
09 - Working and Living Conditions › 091 - Living Conditions › Sanitary Facilities
Issued 11 July 2022
Resolved
at each inspection for certification and at every other vessel inspection, quarters, toilet and washing spaces, galleys, serving pantries, lockers, and similar spaces may be examined to determine that they are serviceable and in a sanitary condition.
MSD ovbd hose was broken and leaking.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Manholes/flush scuttles
Issued 11 July 2022
Resolved
A hatch exposed to the weather must be watertight.
Aft hatch & Fwd hatch failed hose test.
09 - Working and Living Conditions › 091 - Living Conditions › Medical Equipment
Issued 11 July 2022
Resolved
A vessel must carry either a first-aid kit approved under approval series 160.041 or a kit with equivalent contents and instructions. For equivalent kits, the contents must be stowed in a suitable, watertight container that is marked “First-Aid Kit”. A first-aid kit must be easily visible and readily available to the crew.
05 - Radio Communications › N/A - No Subsystem › Satellite EPIRB 406MHz/1.6GHz
Issued 11 July 2022
Resolved
The EPIRB test required by paragraph (a) shall be logged or otherwise documented, as applicable.
EPIRB testing has not been documented.
04 - Emergency Systems › N/A - No Subsystem › Abandon ship drills
Issued 11 July 2022
Resolved
Abandon ship and man overboard drills and training shall be logged or otherwise documented for review by the Coast Guard upon request. The drill entry shall include the following information: (1) Date of the drill and training; and (2) General description of the drill scenario and training topics.
Drills not recorded.
04 - Emergency Systems › N/A - No Subsystem › Fire drills
Issued 11 July 2022
Resolved
Fire fighting drills and training shall be logged or otherwise documented for review by the Coast Guard upon request. The drill entry shall include the following information: (1) Date of the drill and training; and (2) General description of the drill scenario and training topics.
Drills not recorded.
10 - Safety of Navigation › N/A - No Subsystem › Lights, shapes, sound-signals
Issued 11 July 2022
Resolved
All vessels must have navigation lights that are in compliance with the applicable sections of the International and Inland Navigation Rules.
Missing Anchor light.
10 - Safety of Navigation › N/A - No Subsystem › Lights, shapes, sound-signals
Issued 11 July 2022
Resolved
A vessel of 12 meters or more in length shall be provided with a whistle.
No whistle is fitted on the vessel.
11 - Life Saving Appliances › N/A - No Subsystem › Inflatable liferafts
Issued 11 July 2022
Resolved
Every vessel equipped with an inflatable survival craft must have approved placards or other cards containing instructions for launching and inflating inflatable survival craft for the information of persons on board posted in conspicuous places by each inflatable survival craft.
Missing launching instructions.
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 11 July 2022
Resolved
The following spaces must be equipped with a fixed gas fire extinguishing system, in compliance with § 181.410, or other fixed fire extinguishing system specifically approved by the Commandant, except as otherwise allowed by paragraph (b) of this section: (1) A space containing propulsion machinery;
Holes on port and stbd engine room vents.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 11 July 2022
Resolved
on a vessel carrying only one ring buoy, must be attached to the lanyard with a corrosion-resistant clip. The clip must have a strength of at least 22.7 kilograms (50 pounds).
life Line needs corrosion-resistant clip.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 11 July 2022
Resolved
An adult life jacket must be provided for each person carried on board a vessel. (b) In addition, a number of child size life jackets equal to at least 10% of the number of persons permitted on board must be provided, or such greater number as necessary to provide a life jacket for each person being carried that is smaller than the lower size limit of the adult life jackets provided to meet this section.
3 adult life jackets and 1 child life jacket was wasted and serviceable. Reduced to the number of appropriate life jackets on board.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 11 July 2022
Resolved
Each floating waterlight must be approved in accordance with § 161.010 in subchapter Q of this chapter.
Water light battery was expired but replaced on the spot.
02 - Structural Conditions › N/A - No Subsystem › Steering gear
Issued 11 July 2022
Resolved
A vessel must be provided with a main steering gear that is: (1) Of adequate strength and capable of steering the vessel at all service speeds.
Steering ram mounting lags pulled from mounting point. O/O drilled through mounting point and through bolted it. Conducted satisfactory test.
02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 17 February 2022
Resolved
A penetration in a watertight bulkhead must be as high and as far inboard as practicable and made watertight; properly seal the drain hole in the bottom of the forward bulkhead in the #1 void/ battery compartment.
02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 17 February 2022
Resolved
The number of penetrations in a watertight bulkhead must be minimized. A penetration in a watertight bulkhead must be as high and as far inboard as practicable and made watertight; re-route the discharge hose from the engine compartment bilge pump so as not to penetrate the forward bulkhead in the #1 void and properly seal the existing hole in the bulkhead.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 17 February 2022
Resolved
Install a bushing in the steering system tiller arm connection to the hydraulic ram so as to remove excess play.
10 - Safety of Navigation › N/A - No Subsystem › Charts
Issued 1 June 2021
Resolved
Vessel required to carry current/up to date charts for areas transited. Vessel was not equipped with charts of the AICW (#11534).
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 1 June 2021
Resolved
Vessels portable fire extinguishers are required to be stowed to the satisfaction of the [name withheld] brackets for portable fire extinguishers are wasted/missing/broken.
10 - Safety of Navigation › N/A - No Subsystem › Navigation bridge visibility
Issued 1 June 2021
Resolved
Vessels windows and other openings at the operating station must be of sufficient size and properly located to provide an adequate view for safe navigation in all operating conditions. Existing port side cabin sliding glass window was fractured.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Machinery space openings
Issued 1 June 2021
Resolved
All penetrations in a watertight bulkhead shall located as high/inboard as practicable. Existing bulkhead penetrations in way of forward watertight bulkhead in the battery compartment were not properly sealed.
07 - Fire Safety › N/A - No Subsystem › Ventilation
Issued 1 June 2021
Resolved
Vessel required to be equipped with ventilation closure devices for machinery space. The starboard ventilation closure device is not capable of being fully closed due to the port fuel tank vent routing (obstruction).
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 1 June 2021
Resolved
Vessel required to be fitted with rail courses IWO passenger accomodation spaces. Aft rail course is missing securing hardware.
11 - Life Saving Appliances › N/A - No Subsystem › Distress flares
Issued 14 July 2020
Resolved
Vessel required to be equipped with proper type & quantity of visual distress flares for route. Vessel's existing visual distress signals were found expired.
10 - Safety of Navigation › N/A - No Subsystem › Charts
Issued 14 July 2020
Resolved
Vessel required to carry current/up to date marine charts for areas transited. Vessels existing marine chart was damaged/outdated.
09 - Working and Living Conditions › 091 - Living Conditions › Medical Equipment
Issued 14 July 2020
Resolved
Vessel required to be outfitted with a suitable first aid kit for vessels service. Existing first aid kit required updating/replacement of (missing) items.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 14 July 2020
Resolved
Vessels ring life buoy is required to be equipped with a serviceable floating water light. Existing floating water light battery requires replacement.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 14 July 2020
Resolved
Vessels PFD stowage locations are required to be marked with type/qty of PFD's. Existing markings are worn/peeling, requires replacement.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 14 July 2020
Resolved
Vessel required to be fitted with two portable lights. Vessel is missing the required two portable lights.
14 - Pollution Prevention › 144 - MARPOL Annex IV (Not Applicable to PSC Exams conducted in the U.S.) › Sewage treatment plant
Issued 14 July 2020
Resolved
Vessels marine sanitation device is required to fitted with operating instructions. Existing marine sanitation device is not equipped with operating instructions.
02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 14 July 2020
Resolved
Vessel required to undergo inspection to ensure the vessel is in satisfactory condition, fit for service intended and complies with all applicable regulations. Vessels main deck has "soft spots" in way of emergency fuel shut-off valve hatches. Repairs to be effected NLT next scheduled drydock inspection.
02 - Structural Conditions › N/A - No Subsystem › Bulkheads - cracking
Issued 14 July 2020
Resolved
Vessel required to undergo inspection to ensure the vessel is in satisfactory condition, fit for service intended and complies with all applicable regulations. Vessels non-tight bulkhead IWO head is fractured/unsecured. Temporary repairs are authorized until vessels next scheduled drydock inspection.
02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 3 March 2020
Resolved
Vessel is required to be equipped with a fire extinguishing system for the machinery space/engine room. Vessels pre-engineered fire extinguishing system (FIREBOY) required annual servicing.
08 - Alarms › N/A - No Subsystem › Other (alarms)
Issued 3 March 2020
Resolved
Vessel required to be fitted with high water alarms. Vessels high water alarm IWO lazarette was found damaged/unsecured/laying in bilge.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 3 March 2020
Resolved
Installed fuel filter assembly requires the installation of a flame impingiment bowl. Vessel's installed fuel strainer is not equipped with flame impingiment bowl assembly.
02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 3 March 2020
Resolved
Fractured/delamination of FRP IWO transverse stringers IWO machinery space (stbd side) to transom (along centerline).
02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 3 March 2020
Resolved
Delamination of FRP IWO stbd/inboard stringer in battery compartment.
10 - Safety of Navigation › N/A - No Subsystem › Nautical publications
Issued 18 April 2019
Resolved
Vessel required to carry current/up to date navigational publications for areas transited. Vessels Coast Pilot [name withheld], Current Tables and USCG Light List were outdated for areas transited.
05 - Radio Communications › N/A - No Subsystem › VHF radio installation
Issued 18 April 2019
Resolved
Vessels VHF-FM radio-telephone is required to be programmed with MMSI ID # for DSC equipped units. Vessels VHF-FM radio-telephones are not properly programmed with MMSI ID#.
05 - Radio Communications › N/A - No Subsystem › Other (radio communication)
Issued 18 April 2019
Resolved
Vessel required to posess a FCC Safety Radio-Telephony Certificate for communications equipment installed on board. Vessels current FCC Safety Radio-telephony Certificate has expired.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 18 April 2019
Resolved
Vessel required to have a positive shut off valve installed at the hull penetration for bilge piping systems. The stop valve installed in way of fwd machinery space electric submersible bilge pump, starboard side (under helm) was found inoperable/frozen.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 18 April 2019
Resolved
Flexible hose connections are authorized for use in vital/non-vital systems. The flexible hose connection between the main engine turbo and fiberglass exhaust piping was found delaminated (outer jacket/inner jacket) and required replacement.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 18 April 2019
Resolved
Flexible hose connections are authorized for use in vital/non-vital systems. Attending Inspector called out several raw water leaks in/around the fiberglass exhaust piping for the main diesel engine.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 17 July 2018
Resolved
Batteries in lifesaving appliances are required to be changed annually. The batteries found in the vessels floating waterlights (ring buoy & life float) had not been serviced/changed within the annual requirements.
11 - Life Saving Appliances › N/A - No Subsystem › Buoyant apparatus
Issued 17 July 2018
Resolved
Vessels route requires the carriage of one 22 person life float. Existing life float was noted as being beyond its service life/serviceability and requires replacement.
14 - Pollution Prevention › 144 - MARPOL Annex IV (Not Applicable to PSC Exams conducted in the U.S.) › Other (MARPOL Annex IV)
Issued 17 July 2018
Resolved
Operating instructions are required to be posted on board vessel for Type III MSD systems. Attending Inspector(s) noted no instructions were posted.
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 17 July 2018
Resolved
Emergency fuel shut-off valves are required to be marked properly with identification & operating instructions. Vessels emergency fuel shut-off valves were not properly marked.
05 - Radio Communications › N/A - No Subsystem › MF/HF Radio installation
Issued 17 July 2018
Resolved
Vessel's route requires the vessel to carry an operable Single Side Band (SSB) radiotelephone. Vessel does not carry an operable Single Side Band (SSB) radiotelephony. In lieu of the required SSB, the vessel carries a satellite phone. The satellite phone installation does not contain the required base station/cradle or external antenna.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 17 July 2018
Resolved
Vessels is required to be fitted with a steering system suitable for the service intended. Vessels hydraulic steering hose was found with a blister/bubble near the end fitting @ hydraulic ram.
07 - Fire Safety › N/A - No Subsystem › Ventilation
Issued 17 July 2018
Resolved
Vessel is required to have installed ventilation closures, properly installed/marked, for spaces protected by a fixed/pre-engineered fire suppression system. Vessels ventilation closures are not properly identified/marked.
05 - Radio Communications › N/A - No Subsystem › VHF radio installation
Issued 17 July 2018
Resolved
Vessels VHF-FM radiotelephone is required to be installed on board and properly programmed with MMSI #. Vessels has two VHF-FM marine radiotelephones installed, neither of which are properly programmed to meet the DSC requirement.
07 - Fire Safety › N/A - No Subsystem › Fixed fire extinguishing installation
Issued 17 July 2018
Resolved
Vessel is required to be fitted with a fixed fire suppression system/pre-engineered fire suppression system. Vessels installed pre-engineered fire suppression system (bottle) was found in need of repair/servicing due to corrosion/rust.
Engineering › Sea-water System (primary cooling) › Valve
Issued 14 March 2018
Resolved
Through hull valve for raw water wash down pump required replacement.
Engineering › Shafting/Propeller Arrangements › Bearing
Issued 14 March 2018
Resolved
Worn water lubricated bearing (cutlass) IWO shaft log.
Engineering › Bilge Water Management System › Pump
Issued 14 March 2018
Resolved
Electrical submersible bilge pump wiring IWO lazarette was found disconnected.
Communications › Alarms/Indicators › High Water Alarm
Issued 14 March 2018
Resolved
Vessel not equipped with bilge high water alarms IWO lazarette.
Engineering › Bilge Water Management System › Valve
Issued 14 March 2018
Resolved
Attending Inspector(s) noted that the thru-hull valve IWO transom for electric submersible bilge pump discharge hose was seized.
Pollution Prevention/Response › Prevention Equipment › Marine Sanitation Device, Type III
Issued 14 March 2018
Resolved
Attending Inspector(s) noted that the overboard discharge valve for the Type III MSD was seized and the handle was wasted to the point of failure.
Construction/Loadline › Hull › Transverse Frame
Issued 14 March 2018
Resolved
Attending Inspector(s) called out rotted transverse frame IWO machinery space (fwd of main engine).
Construction/Loadline › Hull › Longitudinal Frame
Issued 14 March 2018
Resolved
Attending Inspector(s) called out fractured FRP IWO starboard longitudinal frames (where intersects with transverse framing) IWO starboard machinery space.
Electrical › Electrical Distribution System (service) › Wiring
Issued 14 March 2018
Resolved
Attending Inspector(s) called out dead ended wiring IWO starboard machinery space (beneath main deck).
Engineering › Diesel Engine (propulsion-reduction gear) › Piping (exhaust)
Issued 14 March 2018
Resolved
Attending Inspector(s) called out detiorated/rotted flexible hose IWO vessels primary exhaust piping between muffler and transom.
Engineering › Fuel Oil Storage/Transfer System › Hose
Issued 14 March 2018
Resolved
Attending Inspector(s) called out deteriorated/rotted fuel fill flexible hose IWO port & starboard fuel fill connections.
Stability › Watertight Integrity › General
Issued 14 March 2018
Resolved
Attending Inspector(s) called out "open" bulkhead penetrations IWO starboard watertight bulkhead between machinery space/rod room.
Construction/Loadline › Structures › Deck Plating
Issued 14 March 2018
Resolved
Attending Inspector(s) called out fractured FRP IWO main deck/side shell in lower rod room, port side.
Electrical › Electric Supply System (service) › Battery Installation
Issued 14 March 2018
Resolved
Attending Inspector(s) called out fractured battery box support frame IWO port machinery space.
Engineering › Diesel Engine (propulsion-reduction gear) › Piping (exhaust)
Issued 14 March 2018
Resolved
Attending Inspector(s) noted that the vessels exhaust piping was not equipped with backflow preventers IAW 46 CFR 182.430(c).
Operations/Management › Drug and Alcohol Testing › EAP Display Requirements
Issued 5 June 2017
Resolved
Vessel did not have an established EAP (program)/not displayed on board vessel.
Communications › Radio Communications › EPIRB
Issued 5 June 2017
Resolved
Hydro-static release for EPIRB was found expired (MAY 2017).
Lifesaving › Lifefloat › Float-free Link
Issued 5 June 2017
Resolved
Weak link for life float was undersized.
Navigation › Piloting/Steering › Marine Charts
Issued 5 June 2017
Resolved
Vessel did not carry current/up to date marine charts/navigational publications for areas transited.
Accommodation/Occupational Safety › Medical/First Aid › Medicine Chest
Issued 5 June 2017
Resolved
Expired items found in first aid kit.
Communications › Alarms/Indicators › Bilge Alarm
Issued 5 June 2017
Resolved
Bilge high water alarms were not properly marked for spaces served.
Fire Fighting › Ventilation Systems › Duct Hatches
Issued 5 June 2017
Resolved
Ventilation closures for machinery space were not vapor tight.
Navigation › Collision/Grounding Avoidance › Navigation Lights
Issued 5 June 2017
Resolved
Vessel not equipped with a stern lights (NAV RULES).
Construction/Loadline › Penetrations › Valve Flange
Issued 5 June 2017
Resolved
Thru-hull fittings in way of machinery space were not properly installed (capped over to prevent ingress of water).
Engineering › Sea-water System (primary cooling) › Piping
Issued 5 June 2017
Resolved
Raw water intake/cooling hose between the thru-hull valve and main engine water pump was deteriorated/cracked.
Engineering › Steering Gear System › Rudder Stock
Issued 5 June 2017
Resolved
Tiller arm for primary steering system had excessive play where connected to hydraulic actuator.
Communications › Audible Communications › Horn/Whistle
Issued 25 April 2016
Resolved
Accommodation/Occupational Safety › Medical/First Aid › Medicine Chest
Issued 25 April 2016
Resolved
Navigation › Piloting/Steering › Coast Guard Light List
Issued 25 April 2016
Resolved
Engineering › Lubricating Oil Service System › Gauge
Issued 25 April 2016
Resolved
Fire Fighting › Structural Fire Protection - General › Accommodation Space Protection
Issued 18 January 2011
Resolved
Provide the vessel with structural fire protection IWO the machinery space boundaries where adjacent to accommodation spaces IAW 46 CFR 177.410 (c) (4).
Fire Fighting › Remote Fuel Shutoff › General
Issued 5 October 2010
Resolved
Provide a remote shutoff for the generator fuel tank.
Operations/Management › Bilge/Bilge System Management › Control of Excess Water
Issued 5 October 2010
Resolved
Replace the electric submersible bilge pump in the fwd void with a UL approved pump.
Navigation › Collision/Grounding Avoidance › Navigation Lights
Issued 5 October 2010
Resolved
Repair or replace the lenses on the port and stbd navigation lights due to weathering of the lenses. The lights do not meet the proper intensity for range of two miles.
Lifesaving › Lifefloat › Platform
Issued 5 October 2010
Resolved
Replace the deteriorated retaining line for the man basket on the life float.
Construction/Loadline › Structures › Manhole
Issued 5 October 2010
Resolved
Provide a retaining line to secure the aft hatch to the vessel
Fire Fighting › Portable Dry Chemical Fire Extinguisher › Number
Issued 5 October 2010
Resolved
Replace one of the B I fire extinguishers with a B II or provide an additional B II. The vessel should be equipped with two B II and one B I.
Engineering › Diesel Engine (propulsion-electric) › Bedplate
Issued 23 February 2010
Resolved
Properly repair aft engine mount welds.
Construction/Loadline › Markings › Vessel Name/Home Port
Issued 23 February 2010
Resolved
Repaint vessel name and hailing port on stern.
Engineering › Shafting/Propeller Arrangements › Bearing
Issued 23 February 2010
Resolved
Replace aft cutless bearing.
Construction/Loadline › Hull › Hull Plating
Issued 23 February 2010
Resolved
Repair blisters on stbd bow gel coat
Stability › Watertight Integrity › General
Issued 22 July 2009
Resolved
Repair or replace the forepeak hatch cover so that it is weather-tight as per 46 CFR 179.360.
Construction/Loadline › Hull › Keel
Issued 22 July 2009
Resolved
Properly repair the fractured fiberglass on the aft portion of the keel where the keel joins the hull.
Construction/Loadline › Structures › Superstructure
Issued 22 July 2009
Resolved
Properly repair the fractured fiberglass on the forward starboard corner of the overhead to the cabin.
Engineering › Bilge Water Management System › Valve
Issued 22 July 2009
Resolved
Install a positive shutoff valve at the hull penetration of the submersible electric bilge pumps as per 46 CFR 182.520.
Electrical › Electrical Distribution System (service) › Ground Detection
Issued 7 July 2008
Resolved
Properly secure ground wire in Engine Room
Lifesaving › Lifefloat › Retroreflective Material
Issued 7 July 2008
Resolved
Provide new reflective tape for lifefloat.
Lifesaving › Lifebuoys › Serviceable
Issued 7 July 2008
Resolved
Provide reflective tape for life ring.
Engineering › Fuel Oil Storage/Transfer System › Piping
Issued 7 July 2008
Resolved
Replace fuel transfer line with hard line.
Documentation › Safety/Response Plans/Programs › General Arrangement Plans
Issued 7 July 2008
Resolved
Provide vessel arrangement plans for review.
Casualty record · 1
28 June 2011Routine · role: Transiting Vicinity of Primary Subject · activity 4069625
Each line is an incident investigation the Coast Guard recorded with this hull among the vessels involved, with the date and the classification the Coast Guard gave it, and the bridge, lock or dam the investigation names where it names one. Involvement is not fault. The investigation narrative is not published. Source: IIR, through 2026.
Recorded names · 1
FISHER OF MEN (2011). Names as the Coast Guard recorded them in incident records, with the years they appear; some are renames and some are spelling variants.
Ownership record
The Coast Guard's documentation record for this hull -- the Abstract of Title,
with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National
Vessel Documentation Center, files it here with its date, and every reader of this page gets it.