Records from 1985 to 2013. Most recent: inspection, 21 November 2013.
Inspection history · 60
21 November 2013
Administrative Inspection
Administrative · Sector Upper Mississippi River · USCG Heartland District (CGD-H) · Activity 4756875
26 August 2013
Annual Inspection · Administrative Inspection
Physical examination · Sector Upper Mississippi River · USCG Heartland District (CGD-H) · Activity 4695361
17 July 2012
Deficiency Check
Physical examination · Sector Upper Mississippi River · USCG Heartland District (CGD-H) · Activity 4381874
6 June 2012
COI Inspection
Physical examination · Sector Upper Mississippi River · USCG Heartland District (CGD-H) · Activity 4335477
11 August 2011
Deficiency Check · Annual Inspection
Physical examination · Sector Upper Mississippi River · USCG Heartland District (CGD-H) · Activity 4097340
13 July 2010
Deficiency Check
Physical examination · Sector Upper Mississippi River · USCG Heartland District (CGD-H) · Activity 3795169
2 June 2010
Annual Inspection
Physical examination · Sector Upper Mississippi River · USCG Heartland District (CGD-H) · Activity 3755769
12 June 2009
Annual Inspection
Physical examination · Sector Upper Mississippi River · USCG Heartland District (CGD-H) · Activity 3486584
25 March 2009
In-Service Inspection
Physical examination · Sector Upper Mississippi River · USCG Heartland District (CGD-H) · Activity 3440119
7 August 2008
Annual Inspection · DAPI Audit · Administrative Inspection
Physical examination · Sector Upper Mississippi River · USCG Heartland District (CGD-H) · Activity 3238866
11 March 2008
Drydock Extension · Administrative Inspection
Administrative · Sector Upper Mississippi River · USCG Heartland District (CGD-H) · Activity 3162332
3 January 2008
Administrative Inspection
Administrative · Sector Upper Mississippi River · USCG Heartland District (CGD-H) · Activity 3124144
12 July 2007
Administrative Inspection · COI Inspection
Physical examination · Sector Upper Mississippi River · USCG Heartland District (CGD-H) · Activity 2952604
26 July 2006
Deficiency Check
Physical examination · Sector Upper Mississippi River · USCG Heartland District (CGD-H) · Activity 2725430
22 June 2006
Annual Inspection · Administrative Inspection
Physical examination · Sector Upper Mississippi River · USCG Heartland District (CGD-H) · Activity 2688392
1 August 2005
Deficiency Check
Physical examination · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 2447609
27 July 2005
Uninspected Other
Physical examination · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 2400757
16 November 2004
Administrative Inspection
Administrative · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 2242023
10 August 2004
Annual Inspection
Physical examination · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 2103054
18 June 2004
Hull Examination
Physical examination · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 2103050
23 July 2003
Annual Inspection
Physical examination · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 1839644
12 August 2002
Deficiency Check
Physical examination · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 1658360
24 July 2002
COI Inspection
Physical examination · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 1643879
12 September 2001
Deficiency Check
Physical examination · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 1072422
5 September 2001
Deficiency Check
Physical examination · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 1072066
30 July 2001
Re-Inspection
Physical examination · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 1413998
26 September 2000
Deficiency Check
Physical examination · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 1054314
9 August 2000
Re-Inspection
Physical examination · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 1458785
29 November 1999
Deficiency Check
Physical examination · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 812013
8 November 1999
Type not recorded
No type recorded · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 801699
25 August 1999
Type not recorded
No type recorded · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 145364
30 July 1999
COI Inspection
Physical examination · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 1395286
22 June 1999
Hull Examination
Physical examination · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 1426279
2 February 1999
Administrative
Administrative · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 791122
30 December 1998
Deficiency Check
Physical examination · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 810367
23 November 1998
Re-Inspection
Physical examination · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 1429047
29 August 1997
Deficiency Check
Physical examination · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 1121665
1 August 1997
Re-Inspection
Physical examination · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 1456502
2 August 1996
COI Inspection
Physical examination · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 1438467
3 August 1995
COI Inspection · Deficiency Check
Physical examination · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 1414498
5 August 1994
COI Inspection
Physical examination · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 868837
1 July 1994
Hull Examination
Physical examination · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 861268
22 March 1994
Type not recorded
No type recorded · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 855862
6 August 1993
COI Inspection
Physical examination · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 1152953
9 March 1993
Type not recorded
No type recorded · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 1144925
25 July 1992
COI Inspection
Physical examination · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 1260503
25 July 1991
COI Inspection
Physical examination · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 942136
16 August 1990
Deficiency Check
Physical examination · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 1216971
30 July 1990
COI Inspection
Physical examination · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 1212840
5 September 1989
Deficiency Check
Physical examination · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 1043642
1 August 1989
COI Inspection
Physical examination · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 1346064
23 January 1989
Hull Examination
Physical examination · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 1200768
15 September 1988
Deficiency Check
Physical examination · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 1041813
5 August 1988
COI Inspection · Drydock Extension
Physical examination · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 1344580
1 September 1987
Deficiency Check
Physical examination · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 1309040
6 August 1987
COI Inspection
Physical examination · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 1029413
15 January 1987
Administrative
Administrative · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 1313998
9 September 1986
Deficiency Check
Physical examination · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 1025432
6 August 1986
COI Inspection
Physical examination · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 1294035
23 August 1985
COI Inspection
Physical examination · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 987121
Engineering › Bilge Water Management System › Not Operational
Issued 26 August 2013
Resolved
Make permanent repairs to bilge to ensure dependent operation at all times. Also, make sure pump (when repaired) is properly affixed to the deck with the proper fastners.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 27 August 2013
Accommodation/Occupational Safety › Occupational Safety › Deck Rail
Issued 26 August 2013
Resolved
Repair safety fencing on starboard side of vessel, which was damaged by earlier event, to limit accidental slips/falls of pax or crew over board.
Condition: Damaged By Earlier Event
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 27 August 2013
Operations/Management › Navigation Safety › Proper Use of Navigation/Anchor Lights
Issued 6 June 2012
Resolved
Install special flashing light required at the front of the tow.
Action required: 705 - Other - as specified
Due 6 July 2012
Resolved 17 July 2012
Resolution: Special flashing light meeting Inland Navigation Rules installed.
Construction/Loadline › Markings › Draft Marks/Indicating System
Issued 2 June 2010
Resolved
The "2" foot draft mark was missing on one corner, the space between the 2 & 3 on another corner appeared greater than 6 inches, and none of the draft marks were permenantly marked.
Action required: 705 - Other - as specified
Due 16 August 2010
Resolved 11 August 2011
Resolution: Verified that draft marks were permenantly affixed to the hull.
Navigation › Collision/Grounding Avoidance › Navigation Lights
Issued 25 July 2006
Resolved
Properly renew vessels' stern light lens. Existing lens has blackened and has restricted the lights visibility.
Condition: Unknown
Action required: 705 - Other - as specified
Due 8 August 2006
Resolved 2 August 2006
Electrical › Electric Supply System (service) › Cable
Issued 22 June 2006
Resolved
Properly cap off broken and disconnected shore tie connection stuffing tube and wiring.
Condition: Damaged By Earlier Event
Action required: 705 - Other - as specified
Due 8 August 2006
Resolved 2 August 2006
Communications › Radio Communications › VHF Radiotelephone
Issued 27 July 2005
Resolved
Properly post emergency broadcast placard near VHF radio I.A.W 46 CFR 184.506.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 27 August 2005
Resolved 8 November 2005
Documentation › Logs/Records › Logbook (official)
Issued 27 July 2005
Resolved
Keep ashore a passenger count I.A.W 46 CFR 185.504
Condition: Unknown
Action required: 705 - Other - as specified
Due 27 August 2005
Resolved 8 November 2005
Lifesaving › Lifebuoys
Issued 26 July 2002
Resolved
Renew damaged lifebouy's.
Condition: Improper/Lack of Maintenance
Due 24 August 2002
Resolved 12 August 2002
Resolution: All lifebouy''s where renewed.
Lifesaving
Issued 30 July 2001
Resolved
Install safety line for deckhand man overboard rescue operations as per. vessel man overboard procedures.
Condition: Unknown
Due 30 July 2001
Resolved 30 July 2001
Engineering
Issued 30 July 2001
Resolved
Install covers over rotating belts and machinery on both main engines.
Condition: Unknown
Due 30 July 2001
Resolved 30 July 2001
Electrical
Issued 30 July 2001
Resolved
Install cover over pilot house overhead light.
Condition: Unknown
Due 30 July 2001
Resolved 30 July 2001
Engineering
Issued 30 July 2001
Resolved
Replace reduction gear oil pressure gauges in pilot house with operable gauges.
Condition: Unknown
Due 30 July 2001
Resolved 30 July 2001
Navigation
Issued 30 July 2001
Resolved
Renew white bow light on barge.
Condition: Unknown
Due 30 July 2001
Resolved 30 July 2001
Construction/Loadline
Issued 30 July 2001
Resolved
Prove proper operation of installed bilge pump system.
Condition: Unknown
Due 30 July 2001
Resolved 30 July 2001
Engineering
Issued 30 July 2001
Resolved
Replace oil pressure gauges on both main diesel engines and in pilot house with operable gauges.
Condition: Unknown
Due 30 July 2001
Resolved 30 July 2001
Engineering
Issued 9 August 2000
Resolved
ENSURE PROPER OPERATION OF UTB BRIDGE RPM, WATER TEMPERATURE, AND OIL PRESSURE GAUGES FOR BOTH ENGINES.
Condition: Unknown
Due 9 August 2000
Resolved 9 August 2000
Electrical
Issued 30 July 1999
Resolved
Properly secure wires in engine room on UTV.
Condition: Unknown
Due 30 July 1999
Resolved 30 July 1999
Lifesaving
Issued 30 July 1999
Resolved
Prior to carrying passengers at night, replace lifering light.
Condition: Unknown
Due 30 July 1999
Resolved 30 July 1999
Engineering
Issued 30 July 1999
Resolved
Repair petcock valve on fuel filters on UTV.
Condition: Unknown
Due 30 July 1999
Resolved 30 July 1999
Navigation
Issued 30 July 1999
Resolved
Rewire starboard navigation light.
Condition: Unknown
Due 30 July 1999
Resolved 30 July 1999
Electrical
Issued 30 July 1999
Resolved
Install battery covers on UTV.
Condition: Unknown
Due 30 July 1999
Resolved 30 July 1999
Engineering
Issued 30 July 1999
Resolved
install exhaust guards on UTV.
Condition: Unknown
Due 30 July 1999
Resolved 30 July 1999
Navigation
Issued 30 July 1999
Resolved
Repair leak on Hydraulic steering hose on UTV.
Condition: Unknown
Due 30 July 1999
Resolved 30 July 1999
Electrical
Issued 23 November 1998
Resolved
Repair wiring on all running lights.
Condition: Unknown
Due 23 November 1998
Resolved 23 November 1998
Electrical
Issued 23 November 1998
Resolved
Properly repair or replace 12VDC wire from tender to barge and install proper wire support.
Condition: Unknown
Due 23 November 1998
Resolved 23 November 1998
Lifesaving
Issued 23 November 1998
Resolved
Ensure vessel nane is installed on all life rings.
Condition: Unknown
Due 23 November 1998
Resolved 23 November 1998
Lifesaving
Issued 23 November 1998
Resolved
Replace retro-reflective tape on 68 adult lifejackets. Passengers can be only carried in daylight hours until tape is replaced. All lifejackets must be repaired or replaced by 24 NOV 98.
Condition: Unknown
Due 25 November 1998
Resolved 25 November 1998
Lifesaving
Issued 23 November 1998
Resolved
Replace 2 Torn life jackets.
Condition: Unknown
Due 25 November 1998
Resolved 25 November 1998
Electrical
Issued 1 August 1997
Resolved
Make permanent repairs to wiring on stbd aft running light.
Condition: Unknown
Due 1 August 1997
Resolved 1 August 1997
Lifesaving
Issued 1 August 1997
Resolved
Make repairs to Brussels II's warning horn.
Condition: Unknown
Due 1 August 1997
Resolved 1 August 1997
Fire Fighting
Issued 3 August 1995
Resolved
REPAIR VALVE OF FIRE MAIN DISCHARGE LINE.
Condition: Unknown
Due 18 August 1995
Resolved 22 September 1995
Fire Fighting
Issued 3 August 1995
Resolved
REPLACE LEAKY HOSE.
Condition: Unknown
Due 18 August 1995
Resolved 22 September 1995
Fire Fighting
Issued 3 August 1995
Resolved
REPAIR/REPLACE FIRE PUMP. PORTABLE PUMP TO REMAIN ON BOARD AT ALL TIMES.
Condition: Unknown
Due 20 October 1995
Resolved 26 October 1995
Lifesaving
Issued 30 July 1990
Resolved
MARK ONE TYPE IV THROWABLE DEVICE WITH VESSEL NAME
Condition: Unknown
Due 30 July 1990
Resolved 30 July 1990
Fire Fighting
Issued 30 July 1990
Resolved
REPLACE POWER BILGE PUMP
Condition: Unknown
Due 30 July 1990
Resolved 30 July 1990
Fire Fighting
Issued 30 July 1990
Resolved
REPLACE FIRE AXE
Condition: Unknown
Due 30 July 1990
Resolved 30 July 1990
Construction/Loadline
Issued 30 July 1990
Resolved
PAINT DRAFT MARKS
Condition: Unknown
Due 30 July 1990
Resolved 30 July 1990
Deck/Cargo
Issued 30 July 1990
Resolved
REPAIR/REPLACE HAND BILGE PUMP
Condition: Unknown
Due 30 July 1990
Resolved 30 July 1990
Engineering
Issued 1 August 1989
Resolved
RENEW SUCTION LINE TO HAND PUMP.
Condition: Unknown
Due 1 August 1989
Resolved 1 August 1989
Lifesaving
Issued 1 August 1989
Resolved
RENEW GRAB LINES ON 2 RING BOUYS.
Condition: Unknown
Due 1 August 1989
Resolved 1 August 1989
Lifesaving
Issued 5 August 1988
Resolved
PUT AT LEAST 12" RETROREFLECTIVE MATERIAL ALONG THE TOP EDGE OF ALL ADULT LIFE PRESERVERS.
Condition: Unknown
Due 5 August 1988
Resolved 5 August 1988
Fire Fighting
Issued 5 August 1988
Resolved
HAVE FOUR (4) PORTABLE FIRE EXTINGUISHERS RESERVICED TO LOOSEN ALL DRY CHEMICAL POWDER AND VERIFY WEIGHT OF THE CO2 CYLINDERS. PROVIDE COPY OF THE SERVICE REPORT FROM THE SERVICING COMPANY.
Condition: Unknown
Due 5 August 1988
Resolved 5 August 1988
Engineering
Issued 5 August 1988
Resolved
FREE-UP THE MAIN BILGE PUMP PIPING CONTROL VALVE AT THE BILGE PUMP.
Condition: Unknown
Due 5 August 1988
Resolved 5 August 1988
Lifesaving
Issued 5 August 1988
Resolved
PUT RETROREFLECTIVE MATERIAL ON THE BACKSIDE OF 12 CHILD-SIZE LIFE PRESERVERS OR OBTAIN REPLACEMENTS.
Condition: Unknown
Due 5 August 1988
Resolved 5 August 1988
Documentation
Issued 6 August 1987
Resolved
POST STABILITY LETTER IN ACCORDANCE WITH REQUIREMENTS OF STABILITY LETTER.
Condition: Unknown
Due 6 August 1987
Resolved 6 August 1987
Electrical
Issued 6 August 1987
Resolved
REPAIR ELECTRICAL CONNECTIONS TO RUNNING LIGHTS (PORT/STBD BOTH ENDS) IN ACCORDANCE WITH NATIONAL ELECTRIC CODE AND GOOD MARINE PRACTICE.
Condition: Unknown
Due 6 August 1987
Resolved 6 August 1987
Fire Fighting
Issued 6 August 1986
Resolved
CONDUCT ANNUAL SERVICING OF (3) B-II FIRE EXTINGUISHERS.
Condition: Unknown
Due 6 August 1986
Resolved 6 August 1986
Fire Fighting
Issued 6 August 1986
Resolved
PROVIDE FIRE AXE ONBOARD VESSEL.
Condition: Unknown
Due 6 August 1986
Resolved 6 August 1986
Fire Fighting
Issued 6 August 1986
Resolved
TEST RUN AND PROVE OPERATION OF THE FIRE PUMP IN PRESENCE OF A COAST GUARD INSPECTOR.
Condition: Unknown
Due 6 August 1986
Resolved 6 August 1986
Lifesaving
Issued 23 August 1985
Resolved
REPLACE WORN OUT LIFE RING BOUY WITH A NEW ONE PROPERLY STENCILED.
Condition: Unknown
Due 23 August 1985
Resolved 23 August 1985