Records from 1980 to 1987. Most recent: inspection, 10 July 1987.
Documentation record
Registered dimensions (L × B × D)155.5 ft × 38.1 ft × 12.5 ft
Registered tonnagegross 274 / net 186
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
BuilderBURTON · PORT ARTHUR, TX, UNITED STATES · built 1974
Hull materialSteel
PropulsionDiesel Reduction
Hull shapeNot recorded
Hull configurationNot recorded
Hailing portNot recorded
Trade endorsementsCoastwise, unrestricted, Registry
DocumentationInvalid
Service, as the file records itOffshore Supply Vessel
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it274 - Regulatory (Subpart C or D), Gross Ton
186 - Regulatory (Subpart C or D), Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 September 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.
A report is not offered for this hull: Its record holds only 2 of the seven kinds of material a report is built from: inspections, deficiencies, operational controls, tow-unit appearances, casualty records, dimensions and documentation. That is a statement about the record, not about the vessel. Reports.
Inspection history · 11
10 July 1987
Administrative
Administrative · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1014410
11 July 1986
Type not recorded
No type recorded · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 994673
9 January 1986
Type not recorded
No type recorded · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 991420
18 December 1985
Re-Inspection
Physical examination · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1299194
7 November 1985
Re-Inspection
Physical examination · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 994026
6 November 1984
Type not recorded
No type recorded · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 976289
6 November 1984
Type not recorded
No type recorded · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 976757
19 January 1983
Type not recorded
No type recorded · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 973223
19 January 1983
Type not recorded
No type recorded · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1276476
11 December 1980
Type not recorded
No type recorded · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 970427
11 December 1980
Type not recorded
No type recorded · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 1273703
Unknown
Issued 6 November 1984
Resolved
THE FOLLOWING DEFICIENCY PERTAIN TO THE VESSEL, GEM TIDE, DN556012.
Condition: Unknown
Due 6 November 1984
Resolved 6 November 1984
Fire Fighting
Issued 6 November 1984
Resolved
RENEW THE TEMPORARY FIRE AND BILGE PIPING FORWARD OF THE PUMP IN ACCORDANCEWITH ORIGINAL DWG 447-7 USING AN APPROVED WELDING PROCEDURE AND QUALIFIED WELDERS TO THE SATISFACTION OF THE COGNIZANT OCMI.
Condition: Unknown
Due 6 November 1984
Resolved 6 November 1984
Unknown
Issued 19 January 1983
Resolved
THE FOLLOWING DEFICIENCIES PERTAIN TO THE VESSEL GEM TIDE, DN556012.
Condition: Unknown
Due 19 January 1983
Resolved 19 January 1983
Accommodation/Occupational Safety
Issued 19 January 1983
Resolved
MAKE QUARTERS A/C SYSTEM OPERATIONAL AND INSURE FUNCTIONING OF EMERGENCY SHUTDOWN SWITCH FOR SAME.
Condition: Unknown
Due 19 January 1983
Resolved 19 January 1983
Fire Fighting
Issued 19 January 1983
Resolved
PROVIDE FIRE PUMP CAPABLE OF PROVIDING WATER PRESSURE IN ACCORDANCE WITH 46 CFR 95.10-5(C).
Condition: Unknown
Due 19 January 1983
Resolved 19 January 1983
Construction/Loadline
Issued 19 January 1983
Resolved
BEAD OR PERMANENTLY MARK VESSELS NAME AND HOME PORT ON HULL IN DESIGNATED AREAS.
Condition: Unknown
Due 19 January 1983
Resolved 19 January 1983
Unknown
Issued 19 January 1983
Resolved
PROVIDE COPY OF LOADLINE REGULATIONS SUBCHAPTER "E" FOR THE VESSELS USE.
Condition: Unknown
Due 19 January 1983
Resolved 19 January 1983
Fire Fighting
Issued 19 January 1983
Resolved
PROVIDE AN APPROVED B-II PORTABLE FIRE EXTINGUISHER AT POSITION NO. 11 (SWITCHBOARD).
Condition: Unknown
Due 19 January 1983
Resolved 19 January 1983
Fire Fighting
Issued 19 January 1983
Resolved
PROVIDE ONE (1) 6 FT. APPLICATOR FOR THE ENGINE ROOM FIRE STATION.
Condition: Unknown
Due 19 January 1983
Resolved 19 January 1983
Unknown
Issued 19 January 1983
Resolved
PROVIDE AN AIR SERVICE RELIEF VALVE FOR THE BULK AIR SYSTEM WITH HAND RE- LIEVING GEAR IN ACCORDANCE WITH 46 CFR 54.15-10(C).
Condition: Unknown
Due 19 January 1983
Resolved 19 January 1983
Fire Fighting
Issued 19 January 1983
Resolved
RENEW THAT PORTION OF FIRE MAIN/BILGE PIPING FWD OF PUMP WHICH WAS IMPROP- ERLY REPLACED DURING THE VESSEL'S DRYDOCKING IN JAN 83 WITH PIPING, FITINGS
Condition: Unknown
Due 19 January 1983
Resolved 19 January 1983
Unknown
Issued 19 January 1983
Resolved
(REQUIREMENT 1 CONTINUED) AND FLANGES SPECIFIED ON ORIGINAL DWG 447-7.
Condition: Unknown
Due 19 January 1983
Resolved 19 January 1983
Fire Fighting
Issued 19 January 1983
Resolved
PRIOR TO RENEWAL OF PIPING IN ITEM 1 SUBMIT WELD PROCEDURE IAW 46 CFR 57.03AS REQUIRED BY 56.70-15. ONCE DONE A PERFORMANCE TEST OF THE WELDER TO BE
Condition: Unknown
Due 19 January 1983
Resolved 19 January 1983
Unknown
Issued 19 January 1983
Resolved
(REQUIREMENT 2 CONTINUED) USED SHOULD BE CONDUCTED IN ACCORDANCE WITH 46 CFR 57.05 TO QUALIFY BOTH WELDER AND PROCEDURE. PRESENT INSTALLATION CON-
Condition: Unknown
Due 19 January 1983
Resolved 19 January 1983
Unknown
Issued 19 January 1983
Resolved
(REQUIREMENT 2 CONTINUED) SIDERED TEMPORARY PENDING COMPLETION OF ABOVE RE-QUIREMENTS.
Condition: Unknown
Due 19 January 1983
Resolved 19 January 1983
Navigation
Issued 19 January 1983
Resolved
MAKE RECORDING DEPTH SOUNDER OPERATIONAL.
Condition: Unknown
Due 19 January 1983
Resolved 19 January 1983
Engineering
Issued 19 January 1983
Resolved
PROVIDE MEANS OF CLOSURE FOR FUEL TANK VENT ON STARBOARD SIDE FORWARD.
Condition: Unknown
Due 19 January 1983
Resolved 19 January 1983