Records from 1981 to 2017. Most recent: inspection, 29 June 2017.
A report is not offered for this hull: Its record holds only 2 of the seven kinds of material a report is built from: inspections, deficiencies, operational controls, tow-unit appearances, casualty records, dimensions and documentation. That is a statement about the record, not about the vessel. Reports.
Inspection history · 47
29 June 2017
Administrative Inspection
Administrative · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 6190820
31 January 2012
Annual Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 4234750
19 January 2011
Deficiency Check · Internal Structural Exam · Hull Examination
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 3928277
26 February 2010
Re-Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 3686653
1 April 2009
Deficiency Check · Re-Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 3434288
2 December 2008
Administrative Inspection
Administrative · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 3372865
1 December 2008
Damage Survey · Examination of Repairs
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 3372296
29 April 2008
Examination of Repairs · Re-Inspection · Hull Examination · Deficiency Check
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 3194899
16 April 2007
Annual Inspection · Deficiency Check
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 2909060
4 January 2006
Hull Examination · Examination of Repairs · Deficiency Check · COI Inspection · Internal Structural Exam
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 2560476
1 May 2003
Re-Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 1784151
14 June 2002
Re-Inspection · Hull Examination
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 1656935
2 July 2001
COI Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1391636
10 January 2001
Type not recorded
No type recorded · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 213761
31 August 2000
Hull Examination · Re-Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1433720
18 June 1999
COI Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1446799
1 July 1998
Re-Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1428979
27 July 1997
Administrative
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1116834
15 July 1997
COI Inspection · Hull Examination
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1457483
6 August 1996
Re-Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1388093
5 July 1995
Hull Examination · COI Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1454239
30 November 1994
Type not recorded
No type recorded · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1183088
21 September 1994
Deficiency Check
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1180812
5 August 1994
Re-Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1367133
12 July 1993
COI Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1438076
10 August 1992
Hull Examination · Re-Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1470867
30 July 1991
Administrative
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 936655
16 July 1991
COI Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 939595
24 July 1990
Deficiency Check
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 922715
22 June 1990
Hull Examination · Re-Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1242749
8 August 1989
Deficiency Check
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1209677
13 July 1989
Administrative
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1039145
13 July 1989
Deficiency Check · COI Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1041486
3 March 1989
Type not recorded
No type recorded · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 443492
3 March 1989
Type not recorded
No type recorded · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 459090
17 August 1988
Re-Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1345001
4 November 1987
Administrative
Administrative · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1328643
29 July 1987
Hull Examination · COI Inspection
Physical examination · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1002355
24 June 1987
Administrative
Administrative · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1005472
11 September 1986
Re-Inspection
Physical examination · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1313813
23 August 1985
Credit Drydock · COI Inspection
Physical examination · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 988912
23 August 1985
COI Inspection
Physical examination · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 994019
20 September 1984
Type not recorded
No type recorded · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 976894
24 February 1984
Type not recorded
No type recorded · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1281884
6 October 1983
Type not recorded
No type recorded · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 964801
8 October 1982
Type not recorded
No type recorded · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 965312
8 October 1981
Type not recorded
No type recorded · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 968980
Lifesaving › Rescue Boat › Construction
Issued 1 April 2009
Resolved
Demonstrate Proper operation of rescue Platform. Platform on board did not attach to hull.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 2 April 2009
Communications › Public Address System › Loudspeaker
Issued 1 April 2009
Resolved
Install additional PA speakers to service all berthing spaces
Due 12 April 2009
Resolved 2 April 2009
Engineering › Fuel Oil Service System › Gauge
Issued 1 April 2009
Resolved
Remove Plastic sight guage from LO service tank
Action required: 17 - Rectify deficiencies prior to departure
Resolved 2 April 2009
Engineering › Generator (propulsion/auxiliary-electric) › Fuse (overload/over current protection)
Issued 2 December 2008
Resolved
Vessel struck unknown object, causing water to be found in fuel, causing generator to shut down. Problem is believed to be fracture in fuel tank.
Due 26 December 2008
Resolved 2 April 2009
Fire Fighting › Means of Escape › Blocked
Issued 29 April 2008
Resolved
Emergency ecape hatch was not easily able to open. Conduct maintenence on hatch, mount dogging wrench permanently, and show prope operation.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 5 May 2008
Operations/Management › Drills/Instruction › Man Overboard Recovery
Issued 29 April 2008
Resolved
Conduct and log drills at least monthly iaw 46 CFR. 50% crew change out occurs every 2 weeks.
Action required: 705 - Other - as specified
Resolved 29 April 2008
Operations/Management › Equipment Service/Testing › EPIRB
Issued 29 April 2008
Resolved
Test and Log EPIRB Monthly
Action required: 705 - Other - as specified
Resolved 18 June 2008
Operations/Management › Navigation Safety › Navigation Underway, General
Issued 29 April 2008
Resolved
Update and post Emergency Broadcast placard with ship's name.
Due 26 May 2008
Resolved 5 May 2008
Fire Fighting › Means of Escape › Emergency Lighting
Issued 29 April 2008
Resolved
Install additional emergency lighting for engine room emergency escape.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 5 May 2008
Communications › Alarms/Indicators › Bilge Alarm
Issued 16 April 2007
Resolved
The bilge alarm for the rudder compartment was not audible.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 16 April 2007
Documentation › Certificates/Documents › FCC SSL
Issued 16 April 2007
Resolved
[withheld — contains personal information; the deficiency system, dates, and resolution status are shown above]
Due 30 April 2007
Resolved 2 May 2007
Navigation › Piloting/Steering › Local Notices to Mariners
Issued 1 May 2003
Resolved
Provide notice to mariners.
Action required: 17 - Rectify deficiencies prior to departure
Due 1 June 2003
Resolved 2 May 2003
Documentation › Certificates/Documents › Certificate of Documentation (CG-1270)
Issued 1 May 2003
Resolved
Provide original Certificate of Documentation.
Action required: 17 - Rectify deficiencies prior to departure
Due 1 June 2003
Resolved 2 May 2003
Personnel › Certificates/Documents/Licenses
Issued 1 May 2003
Resolved
[withheld — contains personal information; the deficiency system, dates, and resolution status are shown above]
Action required: 17 - Rectify deficiencies prior to departure
Due 1 June 2003
Resolved 2 May 2003
Stability › Watertight Integrity
Issued 14 June 2002
Resolved
Repair or replace engine room escape hatch.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 22 July 2002
Resolution: Hatch replaced.
Stability › Watertight Integrity
Issued 14 June 2002
Resolved
Provide dogging wrenches as necessary.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 22 July 2002
Resolution: Wrenches provided
Engineering › Pressure Vessel
Issued 14 June 2002
Resolved
Replace wasted pressure vessel.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 22 July 2002
Resolution: Replaced port air reciever.
Engineering
Issued 14 June 2002
Resolved
Replaces missing valve handle as necessary. LEGACY COMPONENT DESC: Piping
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 21 July 2002
Resolution: Valve handles replaced.
Engineering
Issued 14 June 2002
Resolved
Repair bilge / ballast manifold. LEGACY COMPONENT DESC: bilge / ballast manifold
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 21 July 2002
Resolution: Repaired.
Engineering
Issued 5 August 1994
Resolved
REROUTE LUBE OIL TANK VENT AND FILL TO WEATHER DECK.
Condition: Unknown
Due 5 August 1994
Resolved 5 August 1994
Navigation
Issued 5 August 1994
Resolved
REPAIR STEERING PUMP LIGHT INDICATOR.
Condition: Unknown
Due 5 August 1994
Resolved 5 August 1994
Accommodation/Occupational Safety
Issued 5 August 1994
Resolved
INSTALL GUARD FOR SEWAGE PUMP.
Condition: Unknown
Due 5 August 1994
Resolved 5 August 1994
Deck/Cargo
Issued 5 August 1994
Resolved
RENEW ANCHOR CABLE.
Condition: Unknown
Due 5 August 1994
Resolved 5 August 1994
Electrical
Issued 5 August 1994
Resolved
RE-INSTALL JUNCTION BOX IN PILOT HOUSE CONSULE.
Condition: Unknown
Due 5 August 1994
Resolved 5 August 1994
Engineering
Issued 5 August 1994
Resolved
REPAIR MAIN ENGINE TACHS.
Condition: Unknown
Due 5 August 1994
Resolved 5 August 1994
Electrical
Issued 5 August 1994
Resolved
MOUNT JUNCTION BOX IN PANTRY AND PROPERLY RUN WIRES TO BOX.
Condition: Unknown
Due 5 August 1994
Resolved 5 August 1994
Accommodation/Occupational Safety
Issued 5 August 1994
Resolved
INSTALL VENT LIGHT SCREEN FOR GALLEY STOVE VENT.
Condition: Unknown
Due 5 August 1994
Resolved 5 August 1994
Engineering
Issued 5 August 1994
Resolved
PLUG WASTE OIL DECK DISCHARGE LINE.
Condition: Unknown
Due 5 August 1994
Resolved 5 August 1994
Construction/Loadline
Issued 22 June 1990
Resolved
MAKE PERMANENT REPAIRS TO THE THIN SECTION OF 01 DECK PLATE AFT THE PILOT HOUSE TO THE SATISFACTION OF THE COGNIZANT OCMI AND COMPLIANCE WITH NVIC 7-68(D-3-B).
Condition: Unknown
Due 22 June 1990
Resolved 22 June 1990
Unknown
Issued 22 June 1990
Resolved
REPLACE WASTED ENGINE ROOM FLOOR PANELS. SEVERAL PANELS ARE WASTED AND HOLED ON THE EDGES.
Condition: Unknown
Due 22 June 1990
Resolved 22 June 1990
Unknown
Issued 13 July 1989
Resolved
PROVIDE ON BOARD A CERTIFIED COPY OF VESSEL STABILITY LETTER.
Condition: Unknown
Due 13 July 1989
Resolved 13 July 1989
Documentation
Issued 13 July 1989
Resolved
PROVIDE ON BOARD A CERTIFIED COPY OF VESSEL STABILITY LETTER. COMPLY BY: 13AUG89
Condition: Unknown
Due 13 July 1989
Resolved 13 July 1989
Navigation
Issued 29 July 1987
Resolved
REPOSITION VESSEL SIDELIGHT WITHOUT DELAY AFT OF THE FORWARD MOST HEADLIGHTAS REQUIRED BY RULE 23 ANNEX 1 OF THE INTERNATIONAL REGULATIONS FOR PREVENTING COLLISION AT SEA. 1972 (72 COLREGS)
Condition: Unknown
Due 29 July 1987
Resolved 29 July 1987
Unknown
Issued 8 October 1982
Resolved
(REQ. 1 CONTINUED) 08APR84.
Condition: Unknown
Due 8 October 1982
Resolved 8 October 1982
Construction/Loadline
Issued 8 October 1982
Resolved
HULL DAMAGE IN WAY OF PORT AND STBD BILGE CHINES IS TO BE REPAIRED AT VES- SEL'S NEXT CREDIT DRYDOCKING BUT NOT LATER THAN NEXT REQUIRED DRYDOCKING OF
Condition: Unknown
Due 8 October 1982
Resolved 8 October 1982