Records from 2004 to 2025. Most recent: inspection, 7 October 2025.
Inspection history · 21
7 October 2025
Annual Inspection
Physical examination · Marine Safety Detachment Santa Barbara · USCG Southwest District (CGD-SW) · Activity 8247208
28 January 2025
Administrative Inspection · Hull Examination
Physical examination · Marine Safety Detachment Santa Barbara · USCG Southwest District (CGD-SW) · Activity 8071907
12 September 2024
Annual Inspection
Physical examination · Marine Safety Detachment Santa Barbara · USCG Southwest District (CGD-SW) · Activity 8001308
22 September 2023
Annual Inspection · Administrative Inspection
Physical examination · Marine Safety Detachment Santa Barbara · USCG Southwest District (CGD-SW) · Activity 7796731
5 January 2023
Deficiency Check · Hull Examination
Physical examination · Marine Safety Detachment Santa Barbara · USCG Southwest District (CGD-SW) · Activity 7616640
6 December 2022
Plan Review "T" Boat · Administrative Inspection
Administrative · Marine Safety Detachment Santa Barbara · USCG Southwest District (CGD-SW) · Activity 7605265
20 July 2022
Annual Inspection
Physical examination · Marine Safety Detachment Santa Barbara · USCG Southwest District (CGD-SW) · Activity 7500521
6 January 2022
Deficiency Check
Physical examination · Marine Safety Detachment Santa Barbara · USCG Southwest District (CGD-SW) · Activity 7374760
17 June 2021
Deficiency Check · COI Inspection
Physical examination · Marine Safety Detachment Santa Barbara · USCG Southwest District (CGD-SW) · Activity 7207652
19 January 2021
Hull Examination · Damage Survey
Physical examination · Marine Safety Detachment Santa Barbara · USCG Southwest District (CGD-SW) · Activity 7124757
8 October 2020
Deficiency Check
Physical examination · Marine Safety Detachment Santa Barbara · USCG Southwest District (CGD-SW) · Activity 7073653
30 July 2020
Administrative Inspection
Administrative · Marine Safety Detachment Santa Barbara · USCG Southwest District (CGD-SW) · Activity 7020501
8 May 2020
Administrative Inspection
Administrative · Marine Safety Detachment Santa Barbara · USCG Southwest District (CGD-SW) · Activity 6950626
6 September 2019
In-Service Inspection · Administrative Inspection
Physical examination · Marine Safety Detachment Santa Barbara · USCG Southwest District (CGD-SW) · Activity 6804636
28 June 2019
Type not recorded
No type recorded · Marine Safety Detachment Santa Barbara · USCG Southwest District (CGD-SW) · Activity 6744613
3 April 2019
Annual Inspection
Physical examination · Marine Safety Detachment Santa Barbara · USCG Southwest District (CGD-SW) · Activity 6654735
1 October 2018
Type not recorded
No type recorded · Marine Safety Detachment Santa Barbara · USCG Southwest District (CGD-SW) · Activity 6576953
14 March 2018
Annual Inspection
Physical examination · Marine Safety Detachment Santa Barbara · USCG Southwest District (CGD-SW) · Activity 6339338
23 March 2017
Annual Inspection
Physical examination · Marine Safety Detachment Santa Barbara · USCG Southwest District (CGD-SW) · Activity 6111080
8 December 2016
Deficiency Check · Hull Examination
Physical examination · Marine Safety Detachment Santa Barbara · USCG Southwest District (CGD-SW) · Activity 6050427
3 February 2016
COI Inspection · Administrative Inspection · DAPI Audit
Physical examination · Marine Safety Detachment Santa Barbara · USCG Southwest District (CGD-SW) · Activity 5809309
03 - Water/Weathertight Conditions › N/A - No Subsystem › Other (load lines)
Issued 5 January 2023
Resolved
Except for engine exhausts, each inlet or discharge pipe
that penetrates the hull below a line drawn parallel to
and at least 150 millimeters (6 inches) above the
deepest load waterline must have means to prevent water
from entering the vessel if the pipe fractures or
otherwise fails. Below valves are unsat or being
replaced by O/O for convenience.
1. Port M/E Intake Valve (not closing properly)
2. Port Compressor Valve (hard to close)
3. Starboard Bilge Discharge Valve (swapping gate valve
with ball valve).
Once valves have been installed, schedule inspection
with attending marine inspector.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 30 January 2023
Resolution: Objective evidence received in the form of pictures to clear work list item.
04 - Emergency Systems › N/A - No Subsystem › Public address system
Issued 17 June 2021
Resolved
Public address / general alarm not audible in all parts of passenger bunk room. Provide speakers to ensure system is audible in all passenger accessible spaces.
Condition: Improper Installation
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 9 July 2021
Resolution: Vessel demonstrated operation and adequate volume of installed PA/GA speaker.
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 17 June 2021
Resolved
Vessel's three pahse system not isolated properly from shoreside single phase power. When operating using shore power, ensure isolation of three phase loads.
Condition: Improper Installation
Action required: 705 - Other - as specified
Resolved 6 January 2022
Resolution: Vessel generated electricity now isolated from shore power with use of shunt trip breakers
11 - Life Saving Appliances › N/A - No Subsystem › Launching arrangements for survival craft
Issued 1 October 2019
Resolved
Each life float must be stowed so that in the event of the vessel sinking the life floats are able to float free. Three (03) life floats stowed in a deck box on the port side of the upper deck were found to not be in a float free arrangement. The pilothouse structure prevents the deck box lid from floating free. Prove float free arrangement for port side life floats to an attending marine inspector prior to getting underway.
Condition: Improper Installation
Action required: 60 - Rectify deficiencies prior to movement
Due 1 October 2019
Resolved 17 November 2020
Resolution: Arrangemnet is now float free.
07 - Fire Safety › N/A - No Subsystem › Fixed fire extinguishing installation
Issued 1 October 2019
Resolved
Provision must be made for closing all supply duct cowls or scoops and exhaust duct discharge openings for a space protected by a fixed gas extinguishing system. All closure devices must be readily available and mounted in the vicinity of the vent. Starboard side main deck super structure has small openings to the engine room that do not have closure devices. Provide closure devices and prove proper operation to the satisfaction of an attending marine inspector prior to getting underway.
Condition: Improper Installation
Action required: 60 - Rectify deficiencies prior to movement
Due 1 October 2019
Resolved 8 October 2020
Resolution: Starboard side closure devices provided.
08 - Alarms › N/A - No Subsystem › Other (alarms)
Issued 1 October 2019
Resolved
On a vessel of at least 7.9 meters (26 feet) in length, a visual and audible alarm must be provided at the operating station to indicate a high water level in normally unmanned spaces. Vessels constructed of wood must also provide bilge level alarms in all watertight compartments except small buoyancy chambers. Bilge high water level alarm for the vessel's forepeak was inoperable. Prove proper operation of the bilge high level alarm in the forepeak to the satisfaction of an attending marine inspector prior to getting underway.
Condition: Improper/Lack of Maintenance
Action required: 60 - Rectify deficiencies prior to movement
Due 1 October 2019
Resolved 13 October 2020
Resolution: Bilge alarm is working.
07 - Fire Safety › N/A - No Subsystem › Means of escape
Issued 1 October 2019
Resolved
Construction and arrangement shall allow free and unobstructed access to the bunks. Each bunk shall be immediately adjacent to an aisle leading to a means of escape from the lounge area. Double bunks do not allow for free and unobstructed escape for the inside occupant. All double bunks currently installed may only be occupied by one (1) person. Overnight passenger capacity has been determined to be thirty-two (32).
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 1 October 2019
Resolved 16 March 2021
Resolution: Incorporated into COI amendment.
11 - Life Saving Appliances › N/A - No Subsystem › On board training and instructions
Issued 1 October 2019
Resolved
Placards containing instructions for the donning and use of the life jackets aboard the vessel must be posted in conspicuous places that are regularly accessible and visible to the crew and passengers. Vessel has multiple styles of life jackets on board. Provide instructions for donning and use of each type of life jacket carried.
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 31 October 2019
Resolved 8 October 2020
Resolution: Placards provided.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 1 October 2019
Resolved
A vessel of more than 26 feet in length but not more than 65 feet must carry a life buoy which meets the requirements of 46 CFR 180.70 and 46 CFR 160.050. Life buoy was sun damaged, had dry rotted grab lines and buoyant line, and ring buoy was not marked with vessel name. Provide Serviceable ring buoy appropriately provisioned, marked and installed.
Condition: Placed in Improper Service
Action required: 50 - Rectify deficiencies w/in 30 days
Due 31 October 2019
Resolved 8 October 2020
Resolution: Life ring provided.
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 1 October 2019
Resolved
The design, construction, and stowage of portable tanks and related fuel lines and accessories must meet the requirements of ABYC H-25 or other standard specified by the Commandant. Demonstrate that portable gasoline tanks used for the dive tender vessel and stowed on the dive tender vessel and on the aft deck meet ABYC H-25.
Condition: Placed in Improper Service
Action required: 50 - Rectify deficiencies w/in 30 days
Due 31 October 2019
Resolved 16 December 2020
Resolution: Removed portable gas tanks.
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 1 October 2019
Resolved
Mattresses shall be covered with a material that has been treated to give it fire resistant properties. It was unknown if the mattress covers had been treated with a fire resistant material. Provide proof that mattresses were installed prior to March of 1996 and treat all mattress covers with a material to give them fire resistant properties, or install new mattresses that meet the requirements of 46 CFR 177.405(g)(1) or (g)(2).
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 31 October 2019
Resolved 23 November 2020
Resolution: Recceived letter from O/O attesting to the age of the mattresses and that they are covered with fire retardent spray.
07 - Fire Safety › N/A - No Subsystem › Fire detection and alarm system
Issued 1 October 2019
Resolved
All griddles, broilers, and deep fat fryers must be
fitted with a grease extraction hood in compliance with 46 CFR 181.425. Vessel is fitted with a heat detection system approved in accordance with G-MOC Policy 4-98, which was discovered to have a disarming switch fitted. Remove ability to disarm the galley heat detection system. - 46 CFR 181.405
Condition: Placed in Improper Service
Action required: 50 - Rectify deficiencies w/in 30 days
Due 31 October 2019
Resolved 17 June 2021
Resolution: Vessel removed heat detector and replaced with independent modular smoke deteector while completing installation of integrated fixed fire detection system.
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 1 October 2019
Resolved
Repairs or alterations to the equipment that effect the safety of the vessel must not be made without the approval of the cognizant OCMI, to include electrical wiring and power supply systems. Vessel was found with numerous added electrical loads, including a NITROX generating system in the lazarette, food freezers in the lazarette, electric clothes dryer in the lazarette, a shower/bilge drain pump in the lazarette, a new electric double oven in the galley, additional engine room ventilation fans, a salon ice maker, additional salon refrigerator, hydraulic pump for dive platform, and an electric grill on the main deck. In addition, the shore tie was found without a circuit breaker installed at the switchboard. Provide plans for approval showing electrical generating and distribution system as
installed, to include materials used, over current protection details, and load analysis.
Condition: Placed in Improper Service
Action required: 50 - Rectify deficiencies w/in 30 days
Due 31 October 2019
Resolved 9 July 2021
Resolution: Vessel submitted plans and received an approval letter dated 09JUL21.
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 1 October 2019
Resolved
Battery chargers must have an ammeter connected in the charging circuit. One battery charger in the engine room was found to be missing an ammeter. Provide ammeter in each battery charging circuit.
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 31 October 2019
Resolved 26 October 2020
Resolution: Amp meters installed.
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 1 October 2019
Resolved
Electrical equipment on a vessel must be installed and maintained to protect passengers, crew, other persons and the vessel from electrical hazards, and minimize accidental personnel contact with energized parts. Motor controller housing for dive air compressors in the engine room were found to have been modified; Controller housing was found holed for additional ventilation, exposing controller. Provide intact motor controllers which provide protection from electrical hazards.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 31 October 2019
Resolved 21 January 2021
Resolution: Vessel demonstrated that motor controller housing as installed prevents accidental personnel contact.
02 - Structural Conditions › N/A - No Subsystem › Stability/strength/loading information and instruments
Issued 1 October 2019
Resolved
Alterations to the hull, machinery, or equipment that effect the safety of the vessel must not be made without the approval of the cognizant [name withheld] platform installed on transom. Plans are not available demonstrating review of installation. Provide approved plans or submit plans for approval.
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 31 October 2020
Resolved 8 October 2020
Resolution: This defiicency is removed due to the unit finding the drawings.
01 - Certificates & Documentation › 011 - Ships Certificates › Other (certificates)
Issued 3 April 2019
Resolved
Provide current FCC radio station license. If new call sign/MMSI are issued, update VHF/EPIRB and all other impacted documentation.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 3 May 2019
Resolved 22 April 2019
Resolution: Vessel provided new FCC Safety Radio Cartificate.
07 - Fire Safety › N/A - No Subsystem › Maintenance of Fire protection systems
Issued 3 April 2019
Resolved
Provide fixed CO2 fire extinguishing servicing report.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 3 May 2019
Resolved 10 April 2019
Resolution: Vessel provided a copy of the CO2 system servicing report.
10 - Safety of Navigation › N/A - No Subsystem › Nautical publications
Issued 3 April 2019
Resolved
Provide current navigation publications, to include coast pilot, light list, tides and currents.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 3 May 2019
Resolved 10 April 2019
Resolution: Vessel provided copies of relevant nautical publications.
Engineering › Diesel Engine (propulsion-reduction gear) › Seal
Issued 14 December 2016
Resolved
Repair hydraulic leak on port main engine transmission.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 14 January 2017
Resolved 13 January 2017
Construction/Loadline › Hull › Stringer
Issued 8 December 2016
Resolved
Scrape/clean/treat split port bilge stringer outboard of port main engine.
Action required: 705 - Other - as specified
Due 31 December 2016
Resolved 14 December 2016
Construction/Loadline › Hull › Hull Plating
Issued 8 December 2016
Resolved
Grind/treat hull (interior) in way of the stbd sewage valve.
Action required: 705 - Other - as specified
Due 31 December 2016
Resolved 14 December 2016
Construction/Loadline › Penetrations › Valve Flange
Issued 8 December 2016
Resolved
Service the port outboard compressor cooling sea suction valve.
Action required: 705 - Other - as specified
Due 31 December 2016
Resolved 14 December 2016
Construction/Loadline › Structures › Transverse Bulkhead
Issued 8 December 2016
Resolved
Seal seams of collision bulkhead to ensure watertight integrity.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 14 January 2017
Resolved 13 January 2017
Deck/Cargo › Holds/Tanks › Hatch Cover
Issued 8 December 2016
Resolved
Repair the forepeak hatch gasket.
Action required: 705 - Other - as specified
Due 31 December 2016
Resolved 14 December 2016
Operations/Management › Vessel Activity › Underway
Issued 8 December 2016
Resolved
Make vessel available for post drydock check ride.
Action required: 705 - Other - as specified
Due 31 December 2016
Resolved 14 December 2016
Construction/Loadline › Penetrations › Valve Flange
Issued 8 December 2016
Resolved
Service stbd main diesel raw water valve.
Action required: 705 - Other - as specified
Due 31 December 2016
Resolved 14 December 2016