Records from 1999 to 2012. Most recent: inspection, 26 July 2012.
A report is not offered for this hull: Its record holds only 2 of the seven kinds of material a report is built from: inspections, deficiencies, operational controls, tow-unit appearances, casualty records, dimensions and documentation. That is a statement about the record, not about the vessel. Reports.
Inspection history · 59
26 July 2012
Administrative Inspection
Administrative · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 4391335
13 January 2012
COC-MODU Annual
Type not classified · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 4312301
28 December 2011
Type not recorded
No type recorded · Sector Mobile · USCG Heartland District (CGD-H) · Activity 4218134
16 September 2011
Type not recorded
No type recorded · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 4150081
13 January 2011
COC-MODU Renew
Type not classified · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 3928224
5 January 2011
Type not recorded
No type recorded · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 3921178
28 December 2010
Type not recorded
No type recorded · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 3921050
9 December 2010
Type not recorded
No type recorded · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 3907545
15 November 2010
Type not recorded
No type recorded · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 3907478
13 July 2009
Type not recorded
No type recorded · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 3533627
5 February 2009
COC-MODU Renew
Type not classified · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 3536541
2 July 2008
Type not recorded
No type recorded · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 3254562
22 June 2008
Type not recorded
No type recorded · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 3246169
14 February 2008
COC-MODU Annual
Type not classified · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 3147361
23 February 2007
COC-MODU Renew
Type not classified · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 2882638
11 July 2006
Type not recorded
No type recorded · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 2709340
28 June 2006
Type not recorded
No type recorded · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 2709297
17 April 2006
Type not recorded
No type recorded · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 2651491
16 April 2006
Type not recorded
No type recorded · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 2642144
5 April 2006
Type not recorded
No type recorded · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 2622890
8 March 2006
COC-MODU Annual · ISPS III Exam
Physical examination · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 2598382
8 February 2006
Type not recorded
No type recorded · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 2585102
21 January 2006
Type not recorded
No type recorded · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 2576810
16 March 2005
ISPS III Exam · COC-MODU Renew
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 2311731
21 July 2004
COC-MODU Renew
Type not classified · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 2140674
17 December 2003
Type not recorded
No type recorded · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1965820
11 November 2003
Type not recorded
No type recorded · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1965689
2 September 2003
Certificate of Compliance
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1894295
14 August 2003
Type not recorded
No type recorded · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1927926
24 June 2003
Type not recorded
No type recorded · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1825818
21 May 2003
Type not recorded
No type recorded · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1825642
20 March 2003
Administrative Inspection
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1760314
25 January 2003
Administrative Inspection
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1735283
22 September 2002
Administrative Inspection
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1678660
15 July 2002
Administrative Inspection
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1646702
8 July 2002
Certificate of Compliance
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1646622
20 April 2002
Administrative Inspection
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1607075
20 April 2002
Administrative Inspection
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1607088
27 January 2002
Administrative Inspection
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1481635
11 July 2001
Letter of Compliance (Initial/Renewal)
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1471930
22 June 2001
Administrative
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1066964
22 June 2001
Administrative
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1068620
22 June 2001
Administrative
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1068622
20 April 2001
Deficiency Check
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1062372
15 February 2001
Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 287898
12 February 2001
Tank Vessel Examination
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1445768
1 February 2001
Type not recorded
No type recorded · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 770249
23 January 2001
Type not recorded
No type recorded · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 209499
23 January 2001
Administrative
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1057787
3 January 2001
Type not recorded
No type recorded · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 770241
14 September 2000
Type not recorded
No type recorded · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 209497
16 August 2000
Type not recorded
No type recorded · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 767248
18 July 2000
Letter of Compliance (Initial/Renewal)
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1462122
14 July 2000
Type not recorded
No type recorded · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 198294
4 May 2000
Type not recorded
No type recorded · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 63781
16 March 2000
Type not recorded
No type recorded · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 161742
15 December 1999
Administrative
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 812941
16 August 1999
Type not recorded
No type recorded · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 184043
20 July 1999
Letter of Compliance (Initial/Renewal)
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1420180
Fire Fighting › Fixed Fire Detection System › Alarms
Issued 13 January 2012
Resolved
The crew was asked to demonstrate the oil mist detecting system. The crew did not have any written procedures to test the system. Several attempts were made and were unsuccessful. After taking time to figure out how to test the system it was tested. Provide proper procedures and time frames for testing the oil mist detecting system and place in Safety Management System.
Action required: 705 - Other - as specified
Due 13 February 2012
Resolved 22 January 2012
Resolution: Provided proper procedures and time frames for testing the oil mist detecting system and place in Safety Management System.
Documentation › Certificates/Documents › IOPP Certificate
Issued 13 January 2012
Resolved
After reviewing the IOPP certificate and speaking with the Chief Engineer there is a tank missing from the IOPP certificate. Have the Class Society reissue the IOPP certificate with the addition of the Bilge Tank Forward between frames 66-71 and with a capacity of 11.7 cubic meters.
Action required: 705 - Other - as specified
Due 13 February 2012
Resolved 22 January 2012
Resolution: Provided undated IOPP certificate.
Fire Fighting › Means of Escape › Blocked
Issued 13 January 2012
Resolved
Observed secondary means of escape blocked by multiple obstructions in both ROV rooms. Ensure clear pathway for all means of escape in both ROV rooms.
Action required: 705 - Other - as specified
Due 27 January 2012
Resolved 22 January 2012
Resolution: Ensured clear pathway for all means of escape in both ROV rooms.
Engineering › Compressed Air System (start air) › Valve
Issued 13 January 2012
Resolved
Observed pressure relief valves on both emergency generator air tanks set higher than maximum allowable working pressure. Ensure pressure relief valves are set below the Maximum allowable working pressure.
Action required: 705 - Other - as specified
Due 13 February 2012
Resolved 22 January 2012
Resolution: Ensured pressure relief valves are set below the Maximum allowable working pressure.
Lifesaving
Issued 11 July 2001
Resolved
PROPERLY MAINTAIN AND CONDUCT TRAINING FOR IMMERSION SUITS, OR OBTAIN FLAG STATE EXEMPTION LETTER.
Condition: Unknown
Due 11 September 2001
Resolved 3 July 2002
Resolution: Rcvd fax copy of exemption ltr
Documentation
Issued 11 July 2001
Resolved
OBTAIN CITIZENSHIP EXEMPTION LETTER FOR NON US CITIZENS._x001C_ _x001C_ 33 CFR 141.20
Condition: Unknown
Due 28 August 2001
Resolved 28 August 2001
Documentation
Issued 12 February 2001
Resolved
Provide new IOPP certificate that reflects compliance with Regulation 2(2) of ANNEX 1 of MARPOL 73/78. Must comply prior to reissuance of next Letterof Compliance (LOC)._x001C_ _x001C_
Condition: Unknown
Due 12 February 2001
Resolved 12 February 2001
Documentation
Issued 12 February 2001
Resolved
Provide the documents for the Crude Oil Washing (COW) system required by 33CFR 157.118 prior to using system in U. S. waters.
Condition: Unknown
Due 22 March 2001
Resolved 22 March 2001
Deck/Cargo
Issued 12 February 2001
Resolved
Remove the electric space heaters from the cargo pump room while operating vessel in U. S. waters.
Condition: Unknown
Due 22 March 2001
Resolved 22 March 2001
Deck/Cargo
Issued 12 February 2001
Resolved
Develop written operational procedures that ensure all alarms and/or shutdowns are passivated, when needed, rather than modifying the respective(program logic card) set-point.
Condition: Unknown
Due 22 March 2001
Resolved 22 March 2001
Documentation
Issued 12 February 2001
Resolved
Incorporate into the oil transfer procedures a check to ensure the cargo area overfill alarm is audible throughout the cargo deck area.
Condition: Unknown
Due 22 March 2001
Resolved 22 March 2001
Deck/Cargo
Issued 12 February 2001
Resolved
Provide power failure alarm for overfill device alarm panel in accordance with 46 CFR 39.20-7(b)(2), as directed by 33 CFR 155.480.
Condition: Unknown
Due 22 March 2001
Resolved 22 March 2001
Deck/Cargo
Issued 12 February 2001
Resolved
Reove the emergency shutdown (ESD) level 7 (extended well testing and cargosystem) activation from the general ESD by-pass arrangement, per DNV Condition of Class.
Condition: Unknown
Due 22 March 2001
Resolved 22 March 2001
Deck/Cargo
Issued 12 February 2001
Resolved
Provide proper equipment and demonstrate calibration procedures for the IGSgas analyzers in accordance with the manufacturer's instructions.
Condition: Unknown
Due 22 March 2001
Resolved 22 March 2001
Fire Fighting
Issued 20 July 1999
Resolved
PROVIDE CLASSIFICATION SOCIETY APPROVAL ON FIRE AND LIFESAVING PLANS. ENSURE CORRECT IMO SYMBOLOGY IS USED.
Condition: Unknown
Due 20 July 1999
Resolved 20 July 1999
Electrical
Issued 20 July 1999
Resolved
COMPLETE INSTALLATION OF INDUSTRIAL SYSTEMS FOR DRILLING PACKAGE. ELECTRICAL INSTALLATIONS MUST BE MADE TO THE SATISFACTION OF THE ATTENDING MARINE INSPECTOR OR CLASS SURVEYOR PRIOR TO DRILLING OPERATIONS.
Condition: Unknown
Due 20 July 1999
Resolved 20 July 1999
Deck/Cargo
Issued 20 July 1999
Resolved
PRIOR TO STORAGE OF WELL-TEST FLUIDS ON BOARD, VESSEL MUST COMPLETE USCG_x001C_ EXAM UNDER "CARGO BLOCK" SECTION FOR TANK VESSEL EXAMS TO THE SATISFACTION OF THE COGNIZANT OCMI.
Condition: Unknown
Due 20 July 1999
Resolved 20 July 1999