KAYAK

KAYAK is a 1945 freight ship. The Coast Guard has recorded 69 inspections since 1986, most recently in October 2022, along with 239 deficiencies, 1 operational control and 1 casualty investigation in 2006.

Records from 1986 to 2022. Most recent: inspection, 13 October 2022.

Built
1945
Last inspected
13 October 2022
Documentation
Expired · documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

7945405 View on MarineTraffic leaves Maury; a third-party site, nothing from it is stored here
WDN2094
Flag
UNITED STATES
368258780
Maury page id
psix-47978

Inspections, by type

…with no type recorded16
Years with a record 21 calendar years (1986–2022)
The 69 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

This record may be incomplete: the most recent inspection recorded for this vessel was 4 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the General Dry Cargo Ship class in Maury's sources begin in 1980.

Documentation record

Registered dimensions (L × B × D)109.1 ft × 33.2 ft × 9.1 ft
Registered tonnagegross 98 / net 67
ITC dimensions (L × B × D)109.1 ft × 33.2 ft × 9.1 ft
ITC tonnagegross 213 / net 63
BuilderCOMMERCIAL IRON · PORTLAND, OR, UNITED STATES · built 1945
Hull materialSteel
PropulsionDiesel Reduction
Hull shapeNot recorded
Hull configurationNot recorded
Hailing portNOME, AK
Trade endorsementsCoastwise, unrestricted, Registry
DocumentationExpired · issued 30 June 2004
Service, as the file records itFreight Ship
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it98 - Regulatory (Subpart C or D), Gross Ton
213 - Convention (Subpart B), Gross Ton
67 - Regulatory (Subpart C or D), Net Ton
63 - Convention (Subpart B), Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 September 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.

Radio station licence

WDN2094MMSI 368258780 · active · voluntarily equipped · granted 27 May 2022, expires 27 May 2032
WDD2608MMSI 367117520 · cancelled · compulsorily equipped · granted 1 March 2016, cancelled 3 May 2022
WCQ8043MMSI not assigned · expired · voluntarily equipped · granted 11 April 1995, cancelled 11 June 2005
FCC Universal Licensing System ship-station file of 6 September 2026, matched to this hull on its US Official Number. Status and dates are the file’s own. The licensee is not read from the file and is not shown. A lapsed licence’s MMSI is still the number the vessel transmitted under while it was valid.

Inspection history · 69

13 October 2022 Deficiency Check · DAPI Audit · Initial Certification · Administrative Inspection
Physical examination · Sector Western Alaska and U.S. Arctic · USCG Arctic District (CGD-A) · Activity 7572158
13 May 2021 Drydock Exam · Examination of Repairs · Internal Structural Exam · Administrative Inspection
Physical examination · Sector Western Alaska and U.S. Arctic · USCG Arctic District (CGD-A) · Activity 7195688
3 December 2020 Administrative Inspection
Administrative · Marine Safety Detachment Sitka · USCG Arctic District (CGD-A) · Activity 7105859
12 September 2019 Drydock Exam
Physical examination · Marine Safety Detachment Sitka · USCG Arctic District (CGD-A) · Activity 6810666
1 May 2019 Drydock Exam
Physical examination · Marine Safety Detachment Sitka · USCG Arctic District (CGD-A) · Activity 6673914
9 January 2019 Deficiency Check
Physical examination · Marine Safety Detachment Sitka · USCG Arctic District (CGD-A) · Activity 6608230
23 October 2018 Periodic Inspection · DAPI Audit · Administrative Inspection
Physical examination · Sector Southeast Alaska · USCG Arctic District (CGD-A) · Activity 6566108
16 October 2017 DAPI Audit · Annual Inspection · Deficiency Check
Physical examination · Sector Southeast Alaska · USCG Arctic District (CGD-A) · Activity 6289048
5 December 2016 Welding Related Inspections Qualification Testing · Examination of Repairs · Deficiency Check
Physical examination · Marine Safety Detachment Sitka · USCG Arctic District (CGD-A) · Activity 6070033
26 August 2016 COI Inspection · Administrative Inspection
Physical examination · Sector Southeast Alaska · USCG Arctic District (CGD-A) · Activity 5977255
29 April 2016 Deficiency Check
Physical examination · Sector Southeast Alaska · USCG Arctic District (CGD-A) · Activity 5867637
18 April 2016 Deficiency Check
Physical examination · Marine Safety Detachment Sitka · USCG Arctic District (CGD-A) · Activity 5859813
12 April 2016 Deficiency Check
Physical examination · Marine Safety Detachment Sitka · USCG Arctic District (CGD-A) · Activity 5859806
11 April 2016 Deficiency Check
Physical examination · Marine Safety Detachment Sitka · USCG Arctic District (CGD-A) · Activity 5859803
6 April 2016 Drydock Exam · Deficiency Check · Internal Structural Exam
Physical examination · Marine Safety Detachment Sitka · USCG Arctic District (CGD-A) · Activity 5848528
13 January 2016 Administrative Inspection
Administrative · Sector Southeast Alaska · USCG Arctic District (CGD-A) · Activity 5797104
9 November 2015 Deficiency Check
Physical examination · Sector Southeast Alaska · USCG Arctic District (CGD-A) · Activity 5760327
30 October 2015 Deficiency Check
Physical examination · Sector Southeast Alaska · USCG Arctic District (CGD-A) · Activity 5754272
22 October 2015 Annual Inspection
Physical examination · Sector Southeast Alaska · USCG Arctic District (CGD-A) · Activity 5749072
19 August 2011 Hull Examination · COI Inspection · Internal Structural Exam
Physical examination · Marine Safety Detachment Sitka · USCG Arctic District (CGD-A) · Activity 4133864
16 October 2008 Administrative Inspection
Administrative · Marine Safety Detachment Sitka · USCG Arctic District (CGD-A) · Activity 3346207
10 September 2008 Annual Inspection
Physical examination · Marine Safety Detachment Sitka · USCG Arctic District (CGD-A) · Activity 3321831
17 October 2007 Annual Inspection
Physical examination · Marine Safety Detachment Sitka · USCG Arctic District (CGD-A) · Activity 3081948
13 March 2007 Administrative Inspection
Administrative · Marine Safety Detachment Sitka · USCG Arctic District (CGD-A) · Activity 2887485
27 July 2006 Deficiency Check
Physical examination · Marine Safety Detachment Sitka · USCG Arctic District (CGD-A) · Activity 2732139
27 June 2006 Type not recorded
No type recorded · Sector Southeast Alaska · USCG Arctic District (CGD-A) · Activity 2693416
4 January 2006 Hull Examination · Damage Survey · COI Inspection · Internal Structural Exam
Physical examination · MSD SITKA · USCG Arctic District (CGD-A) · Activity 2560982
12 October 1994 Type not recorded
No type recorded · Marine Safety Detachment Kenai · USCG Arctic District (CGD-A) · Activity 706100
7 October 1994 Type not recorded
No type recorded · Marine Safety Detachment Kenai · USCG Arctic District (CGD-A) · Activity 134985
3 March 1994 Administrative
Administrative · MSO ANCHORAGE · USCG Arctic District (CGD-A) · Activity 854478
12 October 1993 MARPOL Annex V Examination · Re-Inspection
Physical examination · MSO ANCHORAGE · USCG Arctic District (CGD-A) · Activity 829601
19 May 1993 Type not recorded
No type recorded · Marine Safety Detachment Kenai · USCG Arctic District (CGD-A) · Activity 526866
3 December 1992 Administrative
Administrative · MSO ANCHORAGE · USCG Arctic District (CGD-A) · Activity 830560
22 October 1992 COI Inspection · MARPOL Annex V Examination
Physical examination · MSO ANCHORAGE · USCG Arctic District (CGD-A) · Activity 1134207
14 October 1992 Type not recorded
No type recorded · MSO ANCHORAGE · USCG Arctic District (CGD-A) · Activity 954089
24 January 1992 Type not recorded
No type recorded · MSO ANCHORAGE · USCG Arctic District (CGD-A) · Activity 1257243
5 December 1991 Administrative
Administrative · MSO ANCHORAGE · USCG Arctic District (CGD-A) · Activity 941477
26 October 1991 Re-Inspection · Hull Examination
Physical examination · MSO ANCHORAGE · USCG Arctic District (CGD-A) · Activity 1250585
9 May 1991 Administrative
Administrative · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 999594
16 April 1991 Administrative
Administrative · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 1220095
2 April 1991 Type not recorded
No type recorded · MSO ANCHORAGE · USCG Arctic District (CGD-A) · Activity 1232392
4 March 1991 Administrative
Administrative · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 928499
11 February 1991 Type not recorded
No type recorded · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 1218963
31 October 1990 Deficiency Check
Physical examination · MSO ANCHORAGE · USCG Arctic District (CGD-A) · Activity 901842
26 October 1990 COI Inspection
Physical examination · MSO ANCHORAGE · USCG Arctic District (CGD-A) · Activity 1234609
24 April 1990 Type not recorded
No type recorded · MSO ANCHORAGE · USCG Arctic District (CGD-A) · Activity 915827
19 April 1990 Type not recorded
No type recorded · MSO ANCHORAGE · USCG Arctic District (CGD-A) · Activity 1216803
2 March 1990 Type not recorded
No type recorded · MSO ANCHORAGE · USCG Arctic District (CGD-A) · Activity 1212548
28 November 1989 Type not recorded
No type recorded · MSO ANCHORAGE · USCG Arctic District (CGD-A) · Activity 927862
25 October 1989 COI Inspection
Physical examination · MSO ANCHORAGE · USCG Arctic District (CGD-A) · Activity 1342540
13 September 1989 Administrative
Administrative · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 1344121
10 May 1989 COI Inspection
Physical examination · MSO ANCHORAGE · USCG Arctic District (CGD-A) · Activity 1041160
7 February 1989 Hull Examination
Physical examination · MSO ANCHORAGE · USCG Arctic District (CGD-A) · Activity 893786
3 December 1988 Type not recorded
No type recorded · MSO ANCHORAGE · USCG Arctic District (CGD-A) · Activity 1207800
10 October 1988 COI Inspection
Physical examination · MSO ANCHORAGE · USCG Arctic District (CGD-A) · Activity 1195419
14 August 1988 Type not recorded
No type recorded · MSO ANCHORAGE · USCG Arctic District (CGD-A) · Activity 503650
12 August 1988 Deficiency Check
Physical examination · MSO ANCHORAGE · USCG Arctic District (CGD-A) · Activity 1344035
1 May 1988 Deficiency Check
Physical examination · MSO ANCHORAGE · USCG Arctic District (CGD-A) · Activity 1199306
1 April 1988 COI Inspection
Physical examination · MSO ANCHORAGE · USCG Arctic District (CGD-A) · Activity 1302533
29 February 1988 Administrative
Administrative · MSO ANCHORAGE · USCG Arctic District (CGD-A) · Activity 1025853
15 December 1987 Deficiency Check
Physical examination · MSO ANCHORAGE · USCG Arctic District (CGD-A) · Activity 1017468
3 December 1987 Type not recorded
No type recorded · MSO ANCHORAGE · USCG Arctic District (CGD-A) · Activity 1002060
24 October 1987 COI Inspection
Physical examination · MSO ANCHORAGE · USCG Arctic District (CGD-A) · Activity 1020611
2 September 1987 Administrative
Administrative · MSO ANCHORAGE · USCG Arctic District (CGD-A) · Activity 1309059
1 September 1987 Administrative
Administrative · MSO ANCHORAGE · USCG Arctic District (CGD-A) · Activity 1308925
28 May 1987 Administrative
Administrative · MSO ANCHORAGE · USCG Arctic District (CGD-A) · Activity 1030059
5 February 1987 Type not recorded
No type recorded · MSO ANCHORAGE · USCG Arctic District (CGD-A) · Activity 1321879
24 October 1986 COI Inspection
Physical examination · MSO ANCHORAGE · USCG Arctic District (CGD-A) · Activity 1002745
24 October 1986 COI Inspection · Hull Examination
Physical examination · MSO ANCHORAGE · USCG Arctic District (CGD-A) · Activity 1017424

Deficiency record · 239

04 - Emergency Systems › N/A - No Subsystem › Fire drills
Issued 13 October 2022 Resolved
Conduct Fire, abandon ship and Man overboard drills underway with US Coast Guard before cargo operations
Action required: 701 - Prior to carriage of passengers/cargo
Due 13 October 2022
Resolved 11 September 2025
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Operation of machinery
Issued 13 October 2022 Resolved
Conduct underway sea trials with US coast Guard before Cargo
Action required: 701 - Prior to carriage of passengers/cargo
Due 13 October 2022
Resolved 11 September 2025
03 - Water/Weathertight Conditions › N/A - No Subsystem › Doors
Issued 13 October 2022 Resolved
Adjust Engine room door from rudder room so all dogs work correctly and door seats correctly
Action required: 701 - Prior to carriage of passengers/cargo
Due 13 October 2022
Resolved 11 September 2025
09 - Working and Living Conditions › 092 - Working Conditions › Guards - fencing around dangerous machinery parts
Issued 13 October 2022 Resolved
Install guards over all rotating machinery in Engine room. Both Mains are missing shaft guards and pulley guards.
Action required: 701 - Prior to carriage of passengers/cargo
Due 13 October 2022
Resolved 11 September 2025
09 - Working and Living Conditions › 092 - Working Conditions › Pipes, wires (insulation)
Issued 13 October 2022 Resolved
Install missing lagging on both Main engine mufflers and readjust all lagging that is loose and misaligned allowing contact with hot metal.
Action required: 701 - Prior to carriage of passengers/cargo
Due 13 October 2022
Resolved 11 September 2025
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 13 October 2022 Resolved
Install installation on overhead in the Engine room where it has been removed for repairs and work.
Action required: 701 - Prior to carriage of passengers/cargo
Due 13 October 2022
Resolved 11 September 2025
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 13 October 2022 Resolved
Repair oil leak on Starboard main engine oil filter housing.
Action required: 701 - Prior to carriage of passengers/cargo
Due 13 October 2022
Resolved 11 September 2025
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 13 October 2022 Resolved
Provide Non-Conducting matting suitable for the specific switchboard voltage must be installed for personnel protection at the front and rear of the switchboard and must extend the entire length of, and be of sufficient width to suit, the operating space.
Action required: 701 - Prior to carriage of passengers/cargo
Due 13 October 2022
Resolved 11 September 2025
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 13 October 2022 Resolved
Provide blocking and bracing for Port generator Battery to prevent shifting.
Action required: 701 - Prior to carriage of passengers/cargo
Due 13 October 2022
Resolved 11 September 2025
07 - Fire Safety › N/A - No Subsystem › Means of escape
Issued 13 October 2022 Resolved
Clear all items in the emergency exit pathway in the generator room on the Starboard side on the tank tops.
Action required: 701 - Prior to carriage of passengers/cargo
Due 13 October 2022
Resolved 11 September 2025
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 13 October 2022 Resolved
Provide wire and piping support for wiring and pipping in the Generator room starboard side by emergency escape scuttle.
Action required: 701 - Prior to carriage of passengers/cargo
Due 13 October 2022
Resolved 11 September 2025
03 - Water/Weathertight Conditions › N/A - No Subsystem › Ventilators, air pipes, casings
Issued 13 October 2022 Resolved
Remove garden hose from generator room starboard side fwd goose neck.
Action required: 701 - Prior to carriage of passengers/cargo
Due 13 October 2022
Resolved 11 September 2025
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 13 October 2022 Resolved
Remove dead-end wiring from overhead by starboard generator and by Air compressors
Action required: 701 - Prior to carriage of passengers/cargo
Due 13 October 2022
Resolved 11 September 2025
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 13 October 2022 Resolved
Remove all extension cords pluged in to powers strips by washer and dryer.
Action required: 701 - Prior to carriage of passengers/cargo
Due 13 October 2022
Resolved 11 September 2025
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Gauges, thermometers, etc
Issued 13 October 2022 Resolved
Prove proper operation of the following alarms and shutdowns for the Main engines. Starboard main engnie, low and high oil level, Both engines Low lube oil shutdown and over speed shut downs.
Action required: 701 - Prior to carriage of passengers/cargo
Due 13 October 2022
Resolved 11 September 2025
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Gauges, thermometers, etc
Issued 13 October 2022 Resolved
Prove proper operation of the following Alarms and Shutdowns for both Generators. Low lube oil alarm and shut down, high jacket water alarm and over speed shutdown.
Action required: 701 - Prior to carriage of passengers/cargo
Due 13 October 2022
Resolved 11 September 2025
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 13 October 2022 Resolved
Prove bilge pump takes suction of water from rudder room space.
Action required: 701 - Prior to carriage of passengers/cargo
Due 13 October 2022
Resolved 11 September 2025
03 - Water/Weathertight Conditions › N/A - No Subsystem › Railing, gangway, walkway and means for safe passage
Issued 13 October 2022 Resolved
Repair broken hand rail by starboard main engine.
Action required: 701 - Prior to carriage of passengers/cargo
Due 13 October 2022
Resolved 11 September 2025
03 - Water/Weathertight Conditions › N/A - No Subsystem › Manholes/flush scuttles
Issued 13 October 2022 Resolved
Make emergency escape hatch in Generator room water tight.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 13 November 2022
Resolved 11 September 2025
03 - Water/Weathertight Conditions › N/A - No Subsystem › Manholes/flush scuttles
Issued 13 October 2022 Resolved
Replace gasket in emergency escape hatch in berthing area adjust dogs and make watertight.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 13 November 2022
Resolved 11 September 2025
07 - Fire Safety › N/A - No Subsystem › Ready availability of fire fighting equipment
Issued 13 October 2022 Resolved
Provide 2 5 gallon jugs of AFFF before carrying package cargo under 49 CFR.
Action required: 701 - Prior to carriage of passengers/cargo
Due 13 October 2022
Resolved 11 September 2025
01 - Certificates & Documentation › 012 - Crew Certificates › Training and qualification MLC - Personnel safety training
Issued 13 October 2022 Resolved
Provide crew that has completed all required training as per 49 CFR 172 and record of training required by 49 CFR 172.704(d) is keep on board for each crew member.
Action required: 701 - Prior to carriage of passengers/cargo
Due 13 October 2022
Resolved 11 September 2025
07 - Fire Safety › N/A - No Subsystem › Fire pumps and its pipes
Issued 13 October 2022 Resolved
Prove proper operation of fire pump while using both fire hoses.
Action required: 701 - Prior to carriage of passengers/cargo
Due 13 October 2022
Resolved 11 September 2025
07 - Fire Safety › N/A - No Subsystem › Fire detection and alarm system
Issued 13 October 2022 Resolved
Install batteries in all UL list smoke detectors on board.
Action required: 701 - Prior to carriage of passengers/cargo
Due 13 October 2022
Resolved 11 September 2025
09 - Working and Living Conditions › 091 - Living Conditions › Lighting (Accommodation)
Issued 13 October 2022 Resolved
Provide light for each Berth.
Action required: 701 - Prior to carriage of passengers/cargo
Due 13 October 2022
Resolved 11 September 2025
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 13 October 2022 Resolved
Submit final as build electrical drawings for AC, DC and Alarm systems to MSC for review and CC Sector Anchorage in 30 days.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 13 November 2022
Resolved 23 December 2022
Resolution: sent to MSC
06 - Cargo Operations Including Equipment › N/A - No Subsystem › Other (cargo)
Issued 13 October 2022 Resolved
Prior to carrying flammable gas (propane) the provide and post No Smoking/ Open flame as PER 49 CFR 176.220.
Action required: 701 - Prior to carriage of passengers/cargo
Due 13 October 2022
Resolved 11 September 2025
07 - Fire Safety › N/A - No Subsystem › Ready availability of fire fighting equipment
Issued 13 October 2022 Resolved
Service all expired Portable Fire extinguisher.
Action required: 701 - Prior to carriage of passengers/cargo
Due 13 October 2022
Resolved 11 September 2025
10 - Safety of Navigation › N/A - No Subsystem › Other (navigation)
Issued 13 October 2022 Resolved
The following operational and navigational requirements must be completed: 1) Ships whistle must be functional 2) Vessel must be equipped with a sound signaling Bell 3) The compass must be swung and a deviation card provided 4) The radar needs its heading aligned 5) Steering system must be calibrated.
Action required: 701 - Prior to carriage of passengers/cargo
Due 13 October 2022
Resolved 11 September 2025
14 - Pollution Prevention › N/A - No Subsystem › VGP: General
Issued 13 October 2022 Resolved
All containment areas must be equipped with a mechanical means of closing each drain.
Action required: 701 - Prior to carriage of passengers/cargo
Due 13 October 2022
Resolved 11 September 2025
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 13 October 2022 Resolved
The following auxiliary related requirements must be completed: 1) Local/Remote fuel shutdown labels & test 2) Flame screens for all vents 3) Vent cover wedges
Action required: 701 - Prior to carriage of passengers/cargo
Due 13 October 2022
Resolved 11 September 2025
01 - Certificates & Documentation › 013 - Documents › Stability Information Booklet
Issued 13 October 2022 Resolved
Provide a updated Stability Analysis to MSC to account for 4 crew members and 16 person in addition to crew for a Max of 20 total persons on a exposed waters. COI is reduced to a total of 4 persons on on board until vessel receives a update Stability Letter.
Action required: 701 - Prior to carriage of passengers/cargo
Due 13 October 2022
Resolved 11 November 2022
Resolution: updated analysis sent to msc
07 - Fire Safety › N/A - No Subsystem › Fire pumps and its pipes
Issued 23 October 2018 Resolved
Repair leaking gasket on fire pump and prove operation
Action required: 60 - Rectify deficiencies prior to movement
Resolved 9 January 2019
Resolution: Verified seal was repaired and witnessed an operational satisfactory test.
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 23 October 2018 Resolved
Replace FWD fire station hose with 75' hose due to holes
Action required: 60 - Rectify deficiencies prior to movement
Resolved 9 January 2019
Resolution: Verified the hose was renewed.
10 - Safety of Navigation › N/A - No Subsystem › Charts
Issued 23 October 2018 Resolved
Provide up to date charts onboard
Action required: 60 - Rectify deficiencies prior to movement
Resolved 9 January 2019
Resolution: Verified up-to-date charts were provided the the primary area of operation.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 23 October 2018 Resolved
Replace port bridge wing lifebuoy
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 9 January 2019
Resolution: Verified the lifebuoy was renewed.
11 - Life Saving Appliances › N/A - No Subsystem › Embarkation arrangement survival craft
Issued 23 October 2018 Resolved
Reinstall both port and starboard embarkation lights for the life rafts
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 9 January 2019
Resolution: Verified embarkation lights were provided and witnessed a satisfactory operational test.
09 - Working and Living Conditions › 091 - Living Conditions › Medical Equipment
Issued 23 October 2018 Resolved
Replace all expired items on both first aid kits
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 30 June 2022
Resolution: all sat
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 23 October 2018 Resolved
Install non-conducting mats or grates in the rear of the electrical switch board in the generator space
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 9 January 2019
Resolution: Verified non-conductive matting was provided at the front and back of the main switchboard.
09 - Working and Living Conditions › 092 - Working Conditions › Protection machines/parts
Issued 23 October 2018 Resolved
Reinstall lagging on port main engine
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 9 January 2019
Resolution: Verified lagging was provided.
09 - Working and Living Conditions › 091 - Living Conditions › Record of inspection
Issued 23 October 2018 Resolved
Vessel shall conduct and log week and semi-annually testing of the emergency light and power systems onboard
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 29 June 2022
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 23 October 2018 Resolved
Provide limit switched on power operated steering system to prevent the rudder from hitting the rudder stops
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 6 July 2022
Resolution: all sat
04 - Emergency Systems › N/A - No Subsystem › Emergency, lighting, batteries and switches
Issued 23 October 2018 Resolved
Replace missing bulbs in e-lights in steering space
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 9 January 2019
Resolution: Verified described elights were provided with a bulb and properly functioned.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 23 October 2018 Resolved
Prove proper operation of local starting of steering pumps
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 6 July 2022
Resolution: all sat
03 - Water/Weathertight Conditions › N/A - No Subsystem › Other (load lines)
Issued 23 October 2018 Resolved
Make emergency escape hatch in port aft berthing water tight
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 9 January 2019
Resolution: Verified hatched was serviced and able to maintain watertight integrity.
Fire Fighting › Fire Main › Condition
Issued 19 October 2017 Resolved
Make permit repairs to leaks in fire main and confirm satisfactory condition of the rest of the fire main.
Action required: 60 - Rectify deficiencies prior to movement
Due 19 October 2017
Resolved 23 October 2018
Resolution: Vessel has repaired all pipping
Electrical › Electric Generation Source (service) › Panelboard
Issued 19 October 2017 Resolved
Make permit repairs to Electrical system due to salt water leaking from the fire main
Action required: 60 - Rectify deficiencies prior to movement
Due 19 October 2017
Resolved 18 January 2018
Resolution: Vessel has installed the rebuilt voltage regulator for the 100K generator. Conducted load test on 100k generator by running all electric equipment onboard for 15 minutes test sat.
Fire Fighting › Portable Dry Chemical Fire Extinguisher › Service
Issued 16 October 2017 Resolved
Prove proper annual servicing of all portable extinguishers at least once every 12 months
Action required: 60 - Rectify deficiencies prior to movement
Resolved 3 November 2017
Resolution: Vesssel serviced all portable extinguishers
Stability › Watertight Integrity › General
Issued 16 October 2017 Resolved
Prove proper operation of all water and weather tight door and hatches.
Action required: 705 - Other - as specified
Due 30 October 2017
Resolved 23 October 2018
Resolution: Vessel repiared all water and weather tight doors and hatches
Engineering › Freshwater Generation System › Piping
Issued 16 October 2017 Resolved
Fix pinhole leak on potable water piping in engine room starboard side overhead.
Action required: 705 - Other - as specified
Due 30 October 2017
Resolved 7 November 2017
Resolution: Vessel repaired potable water pipe in engineroom
Accommodation/Occupational Safety › Occupational Safety › Guards for Exposed Hazards
Issued 16 October 2017 Resolved
Install guard on starboard main engine.
Action required: 705 - Other - as specified
Due 30 October 2017
Resolved 3 November 2017
Resolution: Vesseel installed guards on all engines
Engineering › Diesel Engine (propulsion-direct drive) › Exhaust Manifold
Issued 16 October 2017 Resolved
Vessel must make permanent repairs to exhaust leaks on both main engines.
Action required: 705 - Other - as specified
Due 30 October 2017
Resolved 23 October 2018
Resolution: vessel has made repairs to both main engine exhaust systems
Fire Fighting › Miscellaneous Items › Insulation (Penetration of Oil/Oil Vapors)
Issued 16 October 2017 Resolved
Replace oil covered exhaust lagging on starboard generator.
Action required: 705 - Other - as specified
Due 30 October 2017
Resolved 3 November 2017
Resolution: Vessel installed new exhaust lagging on starboard generator.
Accommodation/Occupational Safety › Heating › Piping
Issued 16 October 2017 Resolved
Install or adjust exhaust lagging on all engines to prevent personal from touching hot exhaust piping.
Action required: 705 - Other - as specified
Due 30 October 2017
Resolved 3 November 2017
Resolution: Vessel has installed or adjust exhaust lagging on all engines
Fire Fighting › Fire Hoses › Condition
Issued 16 October 2017 Resolved
Replace leaking fire hose on main cargo deck.
Action required: 60 - Rectify deficiencies prior to movement
Resolved 3 November 2017
Resolution: Vessel has replaced fire hose
Fire Fighting › Nozzles › Condition
Issued 16 October 2017 Resolved
Prove proper operation of fire nozzles and applicators onboard.
Action required: 60 - Rectify deficiencies prior to movement
Resolved 3 November 2017
Resolution: All fire nozzles and applicators onboard are working properly
Lifesaving › Lifebuoys › Markings (ship name/port)
Issued 16 October 2017 Resolved
Prove proper marking on fire ax, lifebuoys, and emergency lighting.
Action required: 705 - Other - as specified
Due 30 October 2017
Resolved 3 November 2017
Resolution: fire ax, lifebuoys, and emergency lighting are properly marked
Operations/Management › Drills/Instruction › Abandon Ship
Issued 16 October 2017 Resolved
Conduct U/W drills, man overboard and fire drill with CG inspectors.
Action required: 60 - Rectify deficiencies prior to movement
Resolved 3 November 2017
Resolution: Conducted drills with crew all sat.
Deck/Cargo › Cargo Condition › Other Cargo Type
Issued 16 October 2017 Resolved
Vessel must provide onboard additional fire protections onboard the vessel before carriage of portable tanks as listed on COI as per 49CFR176.315
Action required: 701 - Prior to carriage of passengers/cargo
Due 16 October 2017
Resolved 23 October 2018
Resolution: Vessel has not hauled LPG bottles in the last year, Company will provide additional fire protection if they rcvd. a contract for LPG bottles and will contact the CG to show prove of additional equipment is onboard.
Engineering › Freshwater System (jacketwater cooling) › Hose
Issued 16 October 2017 Resolved
Replace worn/wasted flex hoses on engines.
Action required: 705 - Other - as specified
Due 13 November 2017
Resolved 18 January 2018
Resolution: Vessel has replaced all worn and wasted hoses
Stability › Watertight Integrity › Watertight Subdivision Standard
Issued 16 October 2017 Resolved
Make permanent repairs to bulkhead between the engine-room and the generator space watertight.
Action required: 705 - Other - as specified
Due 31 May 2018
Resolved 9 January 2019
Resolution: Verified the tranverse watertight bulkhead and it's penetrations were properly sealed and watertight.
Electrical › Electric Generation Source (emergency) › Power Requirement
Issued 16 October 2017 Resolved
Prove proper operation of all emergency power onboard the vessel.
Action required: 60 - Rectify deficiencies prior to movement
Resolved 8 November 2017
Resolution: Vessel has installed new emergency batteries all tested sat.
Construction/Loadline › Structures › Door
Issued 3 April 2017 Resolved
Make flush deck accommodation space emergency escape hatch watertight.
Action required: 705 - Other - as specified
Due 1 May 2017
Resolved 25 May 2017
Resolution: Witnessed new gasket properly installed and hatch functioning properly.
Fire Fighting › Fire Pumps › Pressure
Issued 26 August 2016 Resolved
Provide fire pump which can produce required pressure and flow rate at upcoming drydock exam. Temporarily authorized to use two (02) portable pumps to charge fire main.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 31 October 2016
Resolved 29 March 2017
Resolution: Verified instalation of new fire pump and witnessed an operational test. Test Sat.
Electrical › Lighting (emergency) › Battery Operated Lantern
Issued 26 August 2016 Resolved
Demonstrate operation of emergency lighting system onboard vessel.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 26 August 2016
Resolution: Emergency batteries were dead. Batteries were replaced and emergency lighting functioned properly.
Navigation › Piloting/Steering › Marine Charts
Issued 26 August 2016 Resolved
Provide up to date nautical charts for areas the vessel operates in.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 31 October 2016
Resolved 3 April 2017
Resolution: Verified charts were corrected up to the latest notice to mariners.
Fire Fighting › Structural - A Class Divisions › Doors
Issued 26 August 2016 Resolved
Install Structural Fire protection on the berthing room emergency egress IAW NVIC 9-97.
Action required: 705 - Other - as specified
Due 2 January 2017
Resolved 3 April 2017
Resolution: Verified the installation of the equivalent of A-60 insulation for steel was applied to the indentified hatches.
Construction/Loadline › Hull › Bottom Plating
Issued 6 April 2016 Resolved
Crop and renew the damaged section of main vertical keel in the #1 void. 46 CFR 92
Condition: Damaged By Earlier Event
Action required: 701 - Prior to carriage of passengers/cargo
Due 1 May 2016
Resolved 18 April 2016
Engineering › Sea-water System (primary cooling) › Sea Chest
Issued 6 April 2016 Resolved
Blank off the 2 unused valves in the portside sea chest. 46 CFR 56
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 1 May 2016
Resolved 11 April 2016
Pollution Prevention/Response › Prevention Equipment › Marine Sanitation Device, Type II
Issued 6 April 2016 Resolved
Repair/replace the MSD overboard valve. 46 CFR 56
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 1 May 2016
Resolved 12 April 2016
Construction/Loadline › Hull › Bottom Plating
Issued 6 April 2016 Resolved
CConduct U/T gauging in the following areas: Bow head log, around the damaged main vertical keel in the #1 void, the main vertical keel in the #2 void, in the pre-existing sea chest on the port side, pitted hull plating in the vicinity of the rub rail, and the hull plating and main vertical keel on the stern and conduct any necessary repairs.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 1 May 2016
Resolved 18 April 2016
Accommodation/Occupational Safety › Sleeping Accommodations › Berth
Issued 6 April 2016 Resolved
Provide means for the escape hatch from the stateroom to open easily. 46 CFR 92.10
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 1 May 2016
Resolved 26 August 2016
Resolution: [name withheld] and [name withheld] witnessed proper operation of escape hatch during COI inspection.
Engineering › Sea-water System (primary cooling) › Piping
Issued 6 April 2016 Resolved
Repair the leak in the starboard keel cooler. 46 CFR 92
Condition: Damaged By Earlier Event
Action required: 701 - Prior to carriage of passengers/cargo
Due 1 May 2016
Resolved 18 April 2016
Construction/Loadline › Hull › Double Hull
Issued 30 October 2015 Resolved
Properly secure two manholes covers located in the FWD & AFT Engineroom installing studs, bolts, & nuts to manholes.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 13 November 2015
Resolved 9 November 2015
Resolution: Done, sat.
Accommodation/Occupational Safety › Medical/First Aid › Medicine Chest
Issued 30 October 2015 Resolved
Renew expired eye wash bottles (6-92) located FWD E/R in a way of forward electrical switchboard.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 13 November 2015
Resolved 9 November 2015
Electrical › Electrical Distribution System (service) › Non-conducting Deck Covering
Issued 30 October 2015 Resolved
Re-install non-conducting electrical matting missing behind the electrical switchboard.
Condition: Placed in Improper Service
Action required: 705 - Other - as specified
Due 30 October 2015
Resolved 30 October 2015
Resolution: Done, sat
Accommodation/Occupational Safety › Occupational Safety › Tripping/Falling Hazard
Issued 30 October 2015 Resolved
Secure for sea in the area forward engineroom of all consumables materials e.g. freezer secure to deck.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 13 November 2015
Resolved 9 November 2015
Resolution: Effort done ...secured! Sat...
Personnel › Certificates/Documents/Licenses › License, Master
Issued 22 October 2015 Resolved
Provide master's valid MMC and medical certificate.
Action required: 705 - Other - as specified
Due 30 April 2016
Resolved 29 April 2016
Resolution: all masters have required license
Personnel › Certificates/Documents/Licenses › License, Radio Officer
Issued 22 October 2015 Resolved
Provide valid FCC Operator's License.
Action required: 705 - Other - as specified
Due 30 April 2016
Resolved 29 April 2016
Resolution: all masters have required fcc permits
Operations/Management › Drills/Instruction › Not Conducted
Issued 22 October 2015 Resolved
Conduct emergency drills, including emergency steering.
Action required: 705 - Other - as specified
Due 1 May 2016
Resolved 29 April 2016
Resolution: sat drills conducted
Lifesaving › Launching Appliances › Lines
Issued 22 October 2015 Resolved
Provide one line throwing appliance.
Action required: 705 - Other - as specified
Due 30 April 2016
Resolved 29 April 2016
Resolution: lifeline provided
Navigation › Emergency Steering › Compass Reading for Emergency Steering
Issued 22 October 2015 Resolved
Update and correct emergency steering procedures in steering gear room.
Action required: 705 - Other - as specified
Due 5 November 2015
Resolved 9 November 2015
Resolution: Done
Navigation › Emergency Steering › Compass Reading for Emergency Steering
Issued 22 October 2015 Resolved
Install rudder angle indicator in steering gear room.
Action required: 705 - Other - as specified
Due 5 November 2015
Resolved 9 November 2015
Deck/Cargo › Mooring/Anchoring › Anchor
Issued 22 October 2015 Resolved
Properly attach anchor to vessel.
Action required: 705 - Other - as specified
Due 5 November 2015
Resolved 30 October 2015
Resolution: Witnessed operational tests port anchor & winch including crew performance, sat.
Stability › Watertight Integrity › General
Issued 22 October 2015 Resolved
Repair both watertight doors in engine space to ensure watertight integrity.
Action required: 705 - Other - as specified
Due 5 November 2015
Resolved 9 November 2015
Resolution: Done...
Stability › Weathertight Integrity › General
Issued 22 October 2015 Resolved
Install bolts on watertight hatch from main deck to steering room.
Action required: 705 - Other - as specified
Due 5 November 2015
Resolved 9 November 2015
Resolution: Done, sat.
Stability › Weathertight Integrity › General
Issued 17 October 2007 Resolved
Replace broken windows in Bridge on port side and in stbd door.
Due 17 November 2007
Resolved 20 December 2007
Lifesaving › Rocket Parachute Flares › General
Issued 17 October 2007 Resolved
Provide 12 Rocket Parachute Flares approved under 160.136
Due 17 November 2007
Resolved 20 December 2007
Resolution: Vessel not over 150 GT so this is not required as per 46 CFR 94.90-5. Old "I".
Electrical › Electrical Distribution System (service) › Wiring
Issued 17 October 2007 Resolved
Seal wire penetrations in pilot house on aft bulkhead.
Condition: Improper Installation
Due 16 November 2007
Resolved 20 December 2007
Fire Fighting › Portable CO2 Fire Extinguisher › Service
Issued 17 October 2007 Resolved
Service portable fire extinguisher on the bow, port side.
Due 16 November 2007
Resolved 20 December 2007
Lifesaving › Lifebuoys › Serviceable
Issued 17 October 2007 Resolved
Provide retro-reflective tape on stbd bridge wing life ring buoy.
Due 17 November 2007
Resolved 20 December 2007
Fire Fighting › Portable CO2 Fire Extinguisher › Service
Issued 17 October 2007 Resolved
Service and properly mount two portable fire extinguishers at the main deck entrance.
Due 16 November 2007
Resolved 20 December 2007
Accommodation/Occupational Safety › Other Accommodation Spaces › Laundry
Issued 17 October 2007 Resolved
Remove paint and flammable stores from the laundry and place in paint locker or remove from vessel.
Due 17 November 2007
Resolved 20 December 2007
Electrical › Electric Generation Source (service) › Generator
Issued 17 October 2007 Resolved
Prove proper operation of the 100 kw generator.
Due 17 November 2007
Resolved 20 December 2007
Electrical › Electrical Distribution System (service) › Conductor
Issued 17 October 2007 Resolved
Replace single wire conductors supplying power to the weather fax with proper cable.
Condition: Placed in Improper Service
Due 16 November 2007
Resolved 20 December 2007
Electrical › Electrical Distribution System (service) › Wiring
Issued 17 October 2007 Resolved
Properly rewire five separate items presently wired to single conductor in overhead of pilot house with a wire nut.
Condition: Placed in Improper Service
Due 16 November 2007
Resolved 20 December 2007
Electrical › Lighting (service) › Conductor
Issued 17 October 2007 Resolved
Properly wire "Chart light" in pilot house. Presently hard wired into circuit with household "Zip " cord.
Due 16 November 2007
Resolved 20 December 2007
Lifesaving › Inflatable Buoyant Apparatus › Approval
Issued 15 June 2006 Resolved
Replace inflatable buoyant apparatus with inflatable liferaft approval 160.151
Condition: Placed in Improper Service
Action required: 701 - Prior to carriage of passengers/cargo
Due 2 July 2006
Resolved 30 June 2006
Engineering › Fuel Oil Storage/Transfer System › Tank
Issued 9 June 2006 Resolved
Provide a Certificate of Financial Responsibility (COFR) or permanently reduce fuel capacity by removing valves, lines and blanking off fuel tanks.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 15 June 2006
Documentation › Safety/Response Plans/Programs › Fire Control Plans
Issued 9 June 2006 Resolved
Mount extinguishers and mark fire stations in accordance with plan.
Action required: 705 - Other - as specified
Resolved 15 June 2006
Accommodation/Occupational Safety › Occupational Safety › Welding/Hot Work
Issued 9 June 2006 Resolved
Provide a cylinder rack for the Oxyacetylene welding equipment.
Action required: 705 - Other - as specified
Resolved 15 June 2006
Accommodation/Occupational Safety › Occupational Safety › Welding/Hot Work
Issued 9 June 2006 Resolved
Permanently install ie: bolt down or remove hard wiring and provide appropriate plug and receptacle for portable MILLER Welding unit in generator room.
Action required: 705 - Other - as specified
Resolved 15 June 2006
Construction/Loadline › Structures › Ventilators
Issued 9 June 2006 Resolved
Provide weathertight hatches or seal tops of two ventilation trunks taken out of service for installation of windows on main deck.
Action required: 705 - Other - as specified
Resolved 15 June 2006
Electrical › Lighting (service) › Conductor
Issued 9 June 2006 Resolved
Remove or rewire portable lighting that is hard wired with zip cord.
Action required: 705 - Other - as specified
Resolved 15 June 2006
Pollution Prevention/Response › Prevention Equipment › Sewage System Piping
Issued 9 June 2006 Resolved
Renew flame screen for sewage system vent.
Action required: 705 - Other - as specified
Resolved 15 June 2006
Electrical › Electrical Distribution System (service) › Wiring
Issued 9 June 2006 Resolved
Remove 200 Plug which was temporarily installed at main distribution panel for additional shore power connection.
Action required: 705 - Other - as specified
Resolved 15 June 2006
Engineering › Compressed Air System (start air) › Receiver/Bottle
Issued 9 June 2006 Resolved
Determine specifications for both engine start air receivers, replace or service the painted pressure relief valves, and open tanks for internal examination.
Action required: 705 - Other - as specified
Resolved 27 July 2006
Resolution: One tank was damaged during removal of inspection port. Both receivers were replaced with a brand new one of sufficient capacity with new relief valves and gauges.
Accommodation/Occupational Safety › Occupational Safety › Deck Rail
Issued 9 June 2006 Resolved
Replace missing hand rail for interior ladder to bridge.
Action required: 705 - Other - as specified
Resolved 15 June 2006
Deck/Cargo › Ballast › Piping
Issued 16 May 2006 Resolved
Renew ballast lines in forward Port and Stbd voids where wasted.
Action required: 705 - Other - as specified
Resolved 15 June 2006
Deck/Cargo › Ballast › Segregated Ballast Tank
Issued 16 May 2006 Resolved
Renew wasted sounding tubes to forward ballast tanks
Action required: 705 - Other - as specified
Resolved 8 June 2006
Deck/Cargo › Ballast › Special Ballast Arrangements
Issued 16 May 2006 Resolved
Remove concrete in both Port & Stbd # 3 or prove that this small amount approx. 3' x 4' and 1'deep tapering with molded hull is not a patch and is part of stability book/calculations.
Condition: Unknown
Action required: 705 - Other - as specified
Resolved 8 June 2006
Resolution: Minor amount of concreet determined to not be ballast nor patch. Stated intent was to fare curve of hull outboard of swash bulkhead to fully allow draining tank.
Construction/Loadline › Hull › Transverse Frame
Issued 16 May 2006 Resolved
Weld areas of missed welds in Port void 4A where missed on bulkhead #32 - 3 places
Action required: 705 - Other - as specified
Resolved 8 June 2006
Construction/Loadline › Structures › Transverse Bulkhead
Issued 16 May 2006 Resolved
Seal 4" open penetration between generator room and Stbd void # 7center at top of bulkhead.
Action required: 705 - Other - as specified
Due 15 June 2006
Resolved 15 June 2006
Construction/Loadline › Hull › Transverse Frame
Issued 19 April 2006 Resolved
Crop and renew flange on frame at aft end of port main diesel engine from where cut for engine mounts and not rewelded, up through wasted area approx. 4 ft. to good metal.
Action required: 705 - Other - as specified
Resolved 8 June 2006
Resolution: Deleted - not structural members - old engine mounts
Electrical › Electrical Distribution System (service) › Junction Box
Issued 19 April 2006 Resolved
In vicinity of the alarm panel on the aft engine room bulkhead, provide a cover for two J-boxes, including the one for where missing cover is hidden by alarm bell.
Action required: 705 - Other - as specified
Resolved 15 June 2006
Electrical › Lighting (service) › Lighting Fixture
Issued 19 April 2006 Resolved
Provide the protective cover for the light (12volt?) over the port main diesel engine.
Action required: 705 - Other - as specified
Resolved 9 June 2006
Electrical › Lighting (service) › Lighting Fixture
Issued 19 April 2006 Resolved
Replace three non-UL-Marine florescent fixtures: two in engine room and one in generator room.
Action required: 705 - Other - as specified
Resolved 9 June 2006
Electrical › Lighting (service) › Lighting Fixture
Issued 19 April 2006 Resolved
Replace covers where missing on UL-Marine florescent fixtures, one in laundry room, two in generator room and repair or replace cover that is held in place with bailing wire.
Action required: 705 - Other - as specified
Resolved 9 June 2006
Electrical › Electrical Distribution System (service) › Wiring
Issued 19 April 2006 Resolved
Remove household wire nuts used in multiple locations from electrical system, control, and alarm wiring or wrap in electrical tape and place in junction boxes.
Action required: 705 - Other - as specified
Resolved 9 June 2006
Electrical › Electrical Distribution System (service) › Wiring
Issued 19 April 2006 Resolved
At the forward and aft transverse watertight bulkheads to the engine room provide proper seal for wire penetrations of bulkhead where some undersized wires run through old stuffing tubes.
Action required: 705 - Other - as specified
Resolved 15 June 2006
Communications › Alarms/Indicators › High Water Alarm
Issued 19 April 2006 Resolved
Repair or replace high water alarm at forward end of engine room where wires are cut and the sensor appears to be painted and inoperable.
Action required: 705 - Other - as specified
Resolved 15 June 2006
Stability › Watertight Integrity › General
Issued 19 April 2006 Resolved
Service gaskets on all watertight doors.
Action required: 705 - Other - as specified
Resolved 15 June 2006
Fire Fighting › Portable Dry Chemical Fire Extinguisher › Service
Issued 19 April 2006 Resolved
Service all portable CO2 and Dry-chemical fire extinguishers on vessel and provide proper marine brackets appropriate for each as identified by each manufacturers on extinguisher.
Action required: 705 - Other - as specified
Resolved 15 June 2006
Electrical › Electrical Distribution System (service) › Wiring
Issued 19 April 2006 Resolved
Remove dead ended wiring from numerous locations.
Action required: 705 - Other - as specified
Resolved 9 June 2006
Construction/Loadline › Hull › Girder
Issued 19 April 2006 Resolved
Repair stbd lower 1" thick x 8" wide x 12" deep girder in generator room where the flange has been cutaway approx. 5" x 16" in two places and saw cut at one end.
Action required: 705 - Other - as specified
Resolved 16 May 2006
Resolution: Deleted - old engine mount - not part of structural calculations
Electrical › Electrical Distribution System (service) › Wiring
Issued 19 April 2006 Resolved
Properly re-run (at overhead in wire trays) all generator cables that are laying on deck, then run on lower girder into the back of the main distribution panel.
Condition: Improper Installation
Action required: 705 - Other - as specified
Resolved 9 June 2006
Communications › Alarms/Indicators › General Alarm
Issued 19 April 2006 Resolved
Move general alarm in generator room aft of the new tonnage bulkhead.
Action required: 705 - Other - as specified
Resolved 15 June 2006
Accommodation/Occupational Safety › Other Accommodation Spaces › Laundry
Issued 19 April 2006 Resolved
Replace plastic flexible vent on laundry dryer with steel ducting.
Action required: 705 - Other - as specified
Resolved 9 June 2006
Resolution: Alluminum Flexible hose installed
Construction/Loadline › Structures › Door
Issued 19 April 2006 Resolved
Replace broken glass on port door to pilot house.
Action required: 705 - Other - as specified
Resolved 15 June 2006
Electrical › Electric Generation Source (service) › Panelboard
Issued 4 January 2006 Resolved
Renew inop ammeter at main electrical panel for 100 KW generator.
Due 15 July 2006
Resolved 27 July 2006
Resolution: Located operating ammeter and frequency meters on another panel.
Communications › Alarms/Indicators › General Alarm
Issued 4 January 2006 Resolved
At general alarm station in generator room provide sign at alarm that states "When alarm sounds go to your station"
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 27 July 2006
Resolution: Sign made and being installed this weekend
Construction/Loadline
Issued 12 October 1993 Resolved
REPAIR OR REPLACE MISSING NUTS AND STUDS ON DECK HATCHES, MAIN DECK AREA.
Condition: Unknown
Due 15 February 1994
Resolved 18 May 2002
Resolution: MISLE Maintenance - Resolved all open deficiencies issued prior to 6/1/1997 where activity was closed and deficiency due date was past
Electrical
Issued 22 October 1992 Resolved
REPAIR/REPLACE LIGHTING FIXTURES WHERE GLOBES, GUARDS, OR DIFFUSERS ARE MISSING. TWO IN STATEROOMS AND TWO IN STEERING AREA.
Condition: Unknown
Due 22 October 1992
Resolved 22 October 1992
Lifesaving
Issued 22 October 1992 Resolved
PROVIDE ADDITIONAL INFLATABLE LIFERAFT PRIOR TO DEPARTURE COOK INLET, ALASKA.
Condition: Unknown
Due 22 October 1992
Resolved 22 October 1992
Lifesaving
Issued 22 October 1992 Resolved
HYDRO TEST BOTH AIR RECEIVERS TO 1.5 MAWP.
Condition: Unknown
Due 22 October 1992
Resolved 22 October 1992
Documentation
Issued 22 October 1992 Resolved
PROVIDE FCC LICENSE SHOWING EPIRB 406
Condition: Unknown
Due 22 October 1992
Resolved 22 October 1992
Navigation
Issued 26 October 1991 Resolved
MAKE CORRECTIONS TO CHARTS AS REQUIRED. CHARTS ARE TO BE CORRECTED UP TO 2 DAYS PRIOR TO ENTRY INTO TRAVELED WATERS. ALL CHARTS TO BE AVAILABLE FOR INSPECTION BY USCG UPON RETURN.
Condition: Unknown
Due 26 October 1991
Resolved 26 October 1991
Electrical
Issued 26 October 1991 Resolved
PERMANENTLY MOUNT LIGHT ABOVE SWITCHBOARD.
Condition: Unknown
Due 26 October 1991
Resolved 26 October 1991
Navigation
Issued 26 October 1991 Resolved
PROVIDE ADEQUATE BELL PER COLREGS
Condition: Unknown
Due 26 October 1991
Resolved 26 October 1991
Engineering
Issued 11 February 1991 Resolved
REVISE THE COAST GUARD APPROVED BILGE PIPING DRAWING AND THE FIRE MAIN PIPING DRAWING TO REFLECT CHANGES MADE IN REGARDS TO PUMPS AND SUBMIT FOR REVIEW AND APPROVAL.
Condition: Unknown
Due 11 February 1991
Resolved 11 February 1991
Electrical
Issued 11 February 1991 Resolved
REVISE THE COAST GUARD APPROVED ELECTRICAL DRAWING AND SUBMIT FOR APPROVAL FOR CHANGES MADE TO THE SHORE TIE CIRCUIT AND THE FIRE PUMP INSTALLATION._x001C_ _x001C_ _x001C_
Condition: Unknown
Due 11 February 1991
Resolved 11 February 1991
Fire Fighting
Issued 26 October 1990 Resolved
PROVIDE PROPER MARINE BRACKETS FOR ALL ON BOARD PORTABLE FIRE EXTINGUISHERS
Condition: Unknown
Due 26 October 1990
Resolved 26 October 1990
Navigation
Issued 26 October 1990 Resolved
REPAIR TO MAKE OPERABLE THE ALARM FOR NO. 2 STEERING MOTOR. THE VESSEL IS TO OPERATE USING NO. 2 PUMP AS A STANDBY UNIT ONLY UNTIL SUCH TIME THE ALARM IS MADE OPERABLE AND PROVEN IN THE PRESENCE OF A C.G. INSPECTOR.
Condition: Unknown
Due 26 October 1990
Resolved 26 October 1990
Navigation
Issued 26 October 1990 Resolved
INSTALL RUDDER STOP ON THE PORT SIDE OF THE RUDDER SYSTEM.
Condition: Unknown
Due 26 October 1990
Resolved 26 October 1990
Unknown
Issued 26 October 1990 Resolved
HYDROSTATICALLY TEST BOTH AIR RECEIVERS AT 1.25 X PRESSURE VESSEL MAWP.
Condition: Unknown
Due 26 October 1990
Resolved 26 October 1990
Electrical
Issued 26 October 1990 Resolved
REPAIR TO MAKE OPERABLE THE OVERSPEED TRIP FOR NO. 2 GENERATOR.
Condition: Unknown
Due 26 October 1990
Resolved 26 October 1990
Unknown
Issued 26 October 1990 Resolved
SUBMIT TEST PROCEDURES FOR PLANT AUTOMATION TO COMMANDANT USCG (MSC) FOR APPROVAL.
Condition: Unknown
Due 26 October 1990
Resolved 26 October 1990
Construction/Loadline
Issued 26 October 1990 Resolved
PROVIDE A PERMANENT STRAINER FOR THE AFT BILGE SUCTION.
Condition: Unknown
Due 26 October 1990
Resolved 26 October 1990
Engineering
Issued 26 October 1990 Resolved
PROVE THE PROPER OPERATION OF OF MAIN ENGINE HIGH JACKET WATER TEMP AND LOSS OF LUBE OIL PRESSURE ALARMS.
Condition: Unknown
Due 26 October 1990
Resolved 26 October 1990
Fire Fighting
Issued 26 October 1990 Resolved
REPAIR OR REPLACE THE FIRE PUMP TO DELIVER REQUIRED PRESSURE AS PER 46 CFR 95.10-5(C).
Condition: Unknown
Due 26 October 1990
Resolved 26 October 1990
Construction/Loadline
Issued 26 October 1990 Resolved
PROVIDE A SECOND BILGE PUMP ON THE BILGE PIPING SYSTEM. ENSURE THE PUMP MEETS THE STANDARDS OF 46 CFR SUBCHAPTER F. THE PORTABLE GAS POWERED PUMP IS TO BE RETAINED ON BOARD THE VESSEL UNTIL THE 2ND FIXED PUMP IS PROVIDED.
Condition: Unknown
Due 26 October 1990
Resolved 26 October 1990
Electrical
Issued 26 October 1990 Resolved
PROVIDE A PROPER INTERLOCK ON THE SHORE TIE TO PREVENT PARALLELING THE VESSEL WITH SHORE POWER. THIS SYSTEM IS TO REMAIN DISCONNECTED AND NOT PLACED IN SERVICE UNTIL THE INTERLOCK IS PROVIDED.
Condition: Unknown
Due 26 October 1990
Resolved 26 October 1990
Electrical
Issued 26 October 1990 Resolved
PROVIDE AND INSTALL LEAD LINING IN THE PORT BATTERY BOX IN THE ENGINE ROOM.
Condition: Unknown
Due 26 October 1990
Resolved 26 October 1990
Construction/Loadline
Issued 26 October 1990 Resolved
REPAIR DAMAGE TO SIDE PLATE AMIDSHIPS ON THE PORT SIDE, CROPPING AND RENEW-ING PLATE AND DAMAGED STRENGTH MEMBERS AS REQUIRED BY THE ATTENDING COAST GUARD INSPECTOR.
Condition: Unknown
Due 26 October 1990
Resolved 26 October 1990
Construction/Loadline
Issued 19 April 1990 Resolved
CROP AND RENEW TO ORIGINAL DAMAGED HULL AREA AND INTERNAL FRAMING IN NO. 5 F/O TANK. REPAIR TANK TOP WHERE HOLED FROM CUTTING ON TANK TOP.
Condition: Unknown
Due 19 April 1990
Resolved 19 April 1990
Navigation
Issued 25 October 1989 Resolved
REMOVE THROUGH HULL FITTINGS IN GEN ROOM PORT SIDE OUTBOARD OF GENERATOR.
Condition: Unknown
Due 25 October 1989
Resolved 25 October 1989
Deck/Cargo
Issued 25 October 1989 Resolved
REPLACE FLAME SCREENS ON BOTH DAY TANK VENTS
Condition: Unknown
Due 25 October 1989
Resolved 25 October 1989
Electrical
Issued 25 October 1989 Resolved
PROVIDE A LIGHT FOR THE TOP BUNK IN THE FWD STATE ROOM STBD SIDE.
Condition: Unknown
Due 25 October 1989
Resolved 25 October 1989
Construction/Loadline
Issued 25 October 1989 Resolved
REPAIR DAMAGE TO STBD FOC'S'LE AREA FWD OF WELL DECK.
Condition: Unknown
Due 25 October 1989
Resolved 25 October 1989
Deck/Cargo
Issued 25 October 1989 Resolved
REPLACE FLAME SCREEN ON MSD VENT.
Condition: Unknown
Due 25 October 1989
Resolved 25 October 1989
Unknown
Issued 25 October 1989 Resolved
REPLACE FRACTURED WINDOWS IN PILOT HOUSE.
Condition: Unknown
Due 25 October 1989
Resolved 25 October 1989
Documentation
Issued 25 October 1989 Resolved
PRIOVIDE CURRENT FCC LIC TO REFLECT VESSEL OWNER.
Condition: Unknown
Due 25 October 1989
Resolved 25 October 1989
Electrical
Issued 25 October 1989 Resolved
SHORTEN ELEC CABLE ON PORT SIDE OF GENERATOR ROOM TO FACILITATE CONTACT OF ARMORED CABLE. (1 3/4" WIRE)
Condition: Unknown
Due 25 October 1989
Resolved 25 October 1989
Unknown
Issued 25 October 1989 Resolved
CLEAR LIMBER HOLES PORT & STBD SIDE OF ENGINE ROOM.
Condition: Unknown
Due 25 October 1989
Resolved 25 October 1989
Documentation
Issued 25 October 1989 Resolved
PROVIDE CURRENT STABILITY INFO TO FACILITATE WRITING OF STABILITY LTR.
Condition: Unknown
Due 25 October 1989
Resolved 25 October 1989
Fire Fighting
Issued 25 October 1989 Resolved
PROVIDE A FIRE PUMP THAT WILL PROVIDE ADEQUATE FIRE PUMP PRESSURE.
Condition: Unknown
Due 25 October 1989
Resolved 25 October 1989
Accommodation/Occupational Safety
Issued 25 October 1989 Resolved
PROVIDE MANUFACTURES INST. FOR MSD.
Condition: Unknown
Due 25 October 1989
Resolved 25 October 1989
Accommodation/Occupational Safety
Issued 25 October 1989 Resolved
PROVIDE NEW CHLORINE TABLET CONTAINER FOR MSD.
Condition: Unknown
Due 25 October 1989
Resolved 25 October 1989
Engineering
Issued 25 October 1989 Resolved
PROVE OPS OF MAIN ENGINE HIGH TEMP ALARMS.
Condition: Unknown
Due 25 October 1989
Resolved 25 October 1989
Electrical
Issued 25 October 1989 Resolved
REPLACE GUARD OVER BRUSH AND STATOR ON PORT GENERATOR.
Condition: Unknown
Due 25 October 1989
Resolved 25 October 1989
Electrical
Issued 25 October 1989 Resolved
REMOVE & REPLACE PORT MAIN ENGINE GUAGE WIRE (RED) AND PROPERLY SUPPORT.
Condition: Unknown
Due 25 October 1989
Resolved 25 October 1989
Electrical
Issued 25 October 1989 Resolved
PROVIDE LENS COVER FOR LIGHT ON PORT SIDE OF PILOT HOUSE.
Condition: Unknown
Due 25 October 1989
Resolved 25 October 1989
Navigation
Issued 25 October 1989 Resolved
ADJUST MAGNETIC COMPASS.
Condition: Unknown
Due 25 October 1989
Resolved 25 October 1989
Construction/Loadline
Issued 25 October 1989 Resolved
REMOVE AS MARKED VERTICAL STIFFENERS ON BULWORKS OF WELL DECK.
Condition: Unknown
Due 25 October 1989
Resolved 25 October 1989
Documentation
Issued 25 October 1989 Resolved
PROVIDE 46 USC FOR VESSEL.
Condition: Unknown
Due 25 October 1989
Resolved 25 October 1989
Documentation
Issued 25 October 1989 Resolved
PROVIDE NOTICE TO MARINERS TO VESSEL.
Condition: Unknown
Due 25 October 1989
Resolved 25 October 1989
Electrical
Issued 25 October 1989 Resolved
CLEAN TERMINALS OF EMERGENCY BATTERIES, PORT SIDE.
Condition: Unknown
Due 25 October 1989
Resolved 25 October 1989
Electrical
Issued 25 October 1989 Resolved
REWIRE OR REPAIR LARGE CABLE SUPPORT OUT OF PANEL #4 TO PROPERLY SUPPORT CABLE.
Condition: Unknown
Due 25 October 1989
Resolved 25 October 1989
Electrical
Issued 25 October 1989 Resolved
PROVE PROPER OPERATION OF 371 GENERATOR OVERSPEED SHUTDOWN.
Condition: Unknown
Due 25 October 1989
Resolved 25 October 1989
Documentation
Issued 25 October 1989 Resolved
PROVIDE WRITTEN OIL TRANSFER PROCEDURES AND A ONE LINE DIAGRAM AS PER 33 CFR 155.720.
Condition: Unknown
Due 25 October 1989
Resolved 25 October 1989
Lifesaving
Issued 10 October 1988 Resolved
PLACE VESSEL'S NAME ON THE RESCUE BOAT.
Condition: Unknown
Due 10 October 1988
Resolved 10 October 1988
Fire Fighting
Issued 10 October 1988 Resolved
PROVIDE EVIDENCE THAT FIRE HOSES ARE APPROVED.
Condition: Unknown
Due 10 October 1988
Resolved 10 October 1988
Lifesaving
Issued 10 October 1988 Resolved
PROVIDE 7TH (ONE ADDITIONAL) SURVIVAL SUIT. THIS ITEM IS TO BE COMPLETED PRIOR TO CARRYING MORE THAN 6 PERSONS AND NOT LATER THAN DATE OF COMPLI- ANCE.
Condition: Unknown
Due 10 October 1988
Resolved 10 October 1988
Lifesaving
Issued 10 October 1988 Resolved
REPLACE THREE DAMAGED LIFE RINGS.
Condition: Unknown
Due 10 October 1988
Resolved 10 October 1988
Fire Fighting
Issued 10 October 1988 Resolved
MAKE REPAIRS TO THE FIRE PUMP TO PROVIDE PROPER PRESSURE AT THE NOZZLE.
Condition: Unknown
Due 10 October 1988
Resolved 10 October 1988
Accommodation/Occupational Safety
Issued 10 October 1988 Resolved
PROVIDE EVIDENCE THAT THE CARPETING IN THE PILOT HOUSE IS COAST GUARD APPROVED
Condition: Unknown
Due 10 October 1988
Resolved 10 October 1988
Engineering
Issued 10 October 1988 Resolved
IN THE PILOT HOUSE PROVIDE BOTH VISUAL AND AUDIBLE ALARMS FOR THE STEERING SYSTEM.
Condition: Unknown
Due 10 October 1988
Resolved 10 October 1988
Lifesaving
Issued 10 October 1988 Resolved
REPLACE EMBARKATION LADDERS FOR THE INFLATABLE LIFE RAFTS.
Condition: Unknown
Due 10 October 1988
Resolved 10 October 1988
Deck/Cargo
Issued 10 October 1988 Resolved
CONDUCT A WEIGHT TEST ON THE CRANE IN PRESENCE OF USCG INSPECTOR OR PROVIDEEVIDENCE OF A WEIGHT TEST.
Condition: Unknown
Due 10 October 1988
Resolved 10 October 1988
Navigation
Issued 10 October 1988 Resolved
PROVIDE PERMANENT AND PROPER INSTRUCTIONS FOR ALIGNMENT OF EMERGENCY STEERING.
Condition: Unknown
Due 10 October 1988
Resolved 10 October 1988
Deck/Cargo
Issued 10 October 1988 Resolved
PLACE GUARDS ON THE ROTATING SHAFTS AT THE STERN WINCH.
Condition: Unknown
Due 10 October 1988
Resolved 10 October 1988
Electrical
Issued 10 October 1988 Resolved
REMOUNT THE ELECTRICAL BOX AT THE FWD END OF THE STERN WINCH.
Condition: Unknown
Due 10 October 1988
Resolved 10 October 1988
Unknown
Issued 10 October 1988 Resolved
INSTALL GUARDS ON COUPLINGS ON THE FIRE PUMP, BILGE PUMP AND FUEL OIL PUMP.
Condition: Unknown
Due 10 October 1988
Resolved 10 October 1988
Electrical
Issued 10 October 1988 Resolved
SECURE WIRE LEADS TO NAVIGATION LIGHTS ATOP PILOT HOUSE.
Condition: Unknown
Due 10 October 1988
Resolved 10 October 1988
Engineering
Issued 10 October 1988 Resolved
REPLACE FRACTURED BOWL ON AIR SUPPLY SYSTEM.
Condition: Unknown
Due 10 October 1988
Resolved 10 October 1988
Engineering
Issued 10 October 1988 Resolved
MAKE OPERABLE THE REMOTE ALARMS AND SHUTDOWNS FOR THE MAIN ENGINES.
Condition: Unknown
Due 10 October 1988
Resolved 10 October 1988
Unknown
Issued 10 October 1988 Resolved
HYDROSTATICALLY TEST BOTH AIR RECEIVERS TO 1 1/4 X MAWP AND PROVIDE DATA PLATES ON BOTH UNITS.
Condition: Unknown
Due 10 October 1988
Resolved 10 October 1988
Electrical
Issued 10 October 1988 Resolved
REMOVE TO SOURCE ALL DEAD END ELECTRICAL WIRES.
Condition: Unknown
Due 10 October 1988
Resolved 10 October 1988
Navigation
Issued 10 October 1988 Resolved
ENSURE ALL NAVIGATIONAL LIGHT SCREENS ARE PAINTED FLAT BLACK.
Condition: Unknown
Due 10 October 1988
Resolved 10 October 1988
Fire Fighting
Issued 10 October 1988 Resolved
PLACE VESSEL'S NAME ON ALL FIRE HOSES AND AXES.
Condition: Unknown
Due 10 October 1988
Resolved 10 October 1988
Fire Fighting
Issued 10 October 1988 Resolved
PROVIDE MARINE BRACKETS FOR ALL PORTABLE FIRE EXTINGUISHERS ON BOARD.
Condition: Unknown
Due 10 October 1988
Resolved 10 October 1988
Construction/Loadline
Issued 10 October 1988 Resolved
REMARK OFFICIAL NUMBER AND NET TONS.
Condition: Unknown
Due 10 October 1988
Resolved 10 October 1988
Construction/Loadline
Issued 10 October 1988 Resolved
PROVIDE STOPS FOR DOGS ON WATER TIGHT DOORS.
Condition: Unknown
Due 10 October 1988
Resolved 10 October 1988
Construction/Loadline
Issued 10 October 1988 Resolved
PROVIDE HOOK FOR DEAD COVER IN SHOWER.
Condition: Unknown
Due 10 October 1988
Resolved 10 October 1988
Electrical
Issued 10 October 1988 Resolved
PROVIDE A MORE SUITABLE BAR TO PREVENT PARALLELING GENERATOR SETS.
Condition: Unknown
Due 10 October 1988
Resolved 10 October 1988
Fire Fighting
Issued 10 October 1988 Resolved
SERVICE ALL CO2 FIRE EXTINGUISHERS ON BOARD. PROVIDE COPY OF SERVICING RE-PORT TO OCMI.
Condition: Unknown
Due 10 October 1988
Resolved 10 October 1988
Construction/Loadline
Issued 10 October 1988 Resolved
REWELD THE LADDER ON THE STARBOARD BOW.
Condition: Unknown
Due 10 October 1988
Resolved 10 October 1988
Construction/Loadline
Issued 10 October 1988 Resolved
REWELD DRAFT MARKINGS ON THE VESSEL SO THEY WILL BE MORE LEGIBLE.
Condition: Unknown
Due 10 October 1988
Resolved 10 October 1988
Lifesaving
Issued 12 August 1988 Resolved
PROVIDE BRACKETS FOR BOTH OF THE LIFE RINGS ON THE BOW.
Condition: Unknown
Due 12 August 1988
Resolved 12 August 1988
Electrical
Issued 12 August 1988 Resolved
PROPERLY SUPPORT ELECTRICAL WIRING IN ENGINEERING SPACES.
Condition: Unknown
Due 12 August 1988
Resolved 12 August 1988
Electrical
Issued 12 August 1988 Resolved
REPAIR THE SHUTDOWN ON THE 30 KW GENERATOR TO FACILITATE COMPLETE SHUTDOWN.
Condition: Unknown
Due 12 August 1988
Resolved 12 August 1988
Engineering
Issued 12 August 1988 Resolved
INSTALL GUARDS OVER THE PULLYS ON THE FORWARD END OF EACH MAIN ENGINE.
Condition: Unknown
Due 12 August 1988
Resolved 12 August 1988
Lifesaving
Issued 12 August 1988 Resolved
REPLACE THE LIFE RING ON THE PORT BRIDGE WING.
Condition: Unknown
Due 12 August 1988
Resolved 12 August 1988
Navigation
Issued 1 April 1988 Resolved
REPAIR/REPLACE TRANSDUCER FOR FATHOMETER
Condition: Unknown
Due 1 April 1988
Resolved 1 April 1988
Electrical
Issued 1 April 1988 Resolved
PROVIDE GLOBES AND GUARDS ON LIGHTING FIXTURES IN AFT MACHINERY SPACE THAT ARE MISSING THE SAME.
Condition: Unknown
Due 1 April 1988
Resolved 1 April 1988
Electrical
Issued 1 April 1988 Resolved
REMOVE AND REPLACE BATTERY CABLE FOR 100 KW AUX GENERATOR STARTING SYSTEM.
Condition: Unknown
Due 1 April 1988
Resolved 1 April 1988
Navigation
Issued 1 April 1988 Resolved
READJUST RUDDER POST CONNECTING BAR TO PORT RUDDER QUADRANT TO PRECLUDE CHAFING.
Condition: Unknown
Due 1 April 1988
Resolved 1 April 1988
Electrical
Issued 1 April 1988 Resolved
REPAIR/REPLACE CYCLY METER FOR 100 KW AUX GENERATOR.
Condition: Unknown
Due 1 April 1988
Resolved 1 April 1988
Construction/Loadline
Issued 1 April 1988 Resolved
REWELD FRACTURED JOINT ON BULLWARK ON PORTSIDE APPROXIMATELY SIX FEET FORWARD OF DECKHOUSE.
Condition: Unknown
Due 1 April 1988
Resolved 1 April 1988
Electrical
Issued 1 April 1988 Resolved
PROVIDE GUARDS FOR PULLEYS ON 100 KW AUX GENERATOR
Condition: Unknown
Due 1 April 1988
Resolved 1 April 1988
Electrical
Issued 1 April 1988 Resolved
PROVIDE LOW LUBE OIL AND HIGH WATER TEMP SHUT DOWNS AND ALARMS FOR BOTH AUX GENERATORS.
Condition: Unknown
Due 1 April 1988
Resolved 1 April 1988
Electrical
Issued 24 October 1987 Resolved
PROVIDE SLIDE LOCKOUT DEVICE ON MAIN GENERATOR SWITCHBOARD TO PREVENT INADVERTENT ENERGIZING OF BOTH UNPARALLELED GENERATORS.
Condition: Unknown
Due 24 October 1987
Resolved 24 October 1987
Unknown
Issued 24 October 1987 Resolved
REROUTE AIR RECEIVER PIPING BETWEEN THE TWO SHIP SERVICE AIR RECEIVERS TO PRECLUDE ROUTING OF RELIEF VALVE EXHAUST INTO SECOND AIR RECEIVER. REMOVE REMOVE EXISTNG FLEX HOSE AND REPLACE WITH PROPER SHEDULE PIPING.
Condition: Unknown
Due 24 October 1987
Resolved 24 October 1987
Engineering
Issued 24 October 1987 Resolved
REPAIR OR REPLACE FORWARD ENGINE ROOM ENGINE ROOM BILGE ALARM FLOAT.
Condition: Unknown
Due 24 October 1987
Resolved 24 October 1987
Electrical
Issued 24 October 1987 Resolved
PROVIDE COVERS ON FLOURESCENT LIGHT FIXTURES IN ACCOMODATION SPACES AND STEERING GEAR SPACES.
Condition: Unknown
Due 24 October 1987
Resolved 24 October 1987
Electrical
Issued 24 October 1987 Resolved
PROVIDE COVER FOR STEERING GEAR CONTROL SOLENOID JUNCTION BOX
Condition: Unknown
Due 24 October 1987
Resolved 24 October 1987
Electrical
Issued 24 October 1987 Resolved
PROVIDE COVERS FOR ELECTRICAL JUNCTION BOXES IN WAY OF AFT ENGINE ROOM BILGE ALARM AND STEERING GEAR.
Condition: Unknown
Due 24 October 1987
Resolved 24 October 1987
Electrical
Issued 24 October 1987 Resolved
REMOVE OLD UNUSED UNSHIELDED CABLE AND REPLACE WITH APPROVED SHIELDED CABLEBETWEEN STARTING BATTERIES AND GM871 DIESEL GENERATOR.
Condition: Unknown
Due 24 October 1987
Resolved 24 October 1987
Electrical
Issued 24 October 1987 Resolved
PROVIDE GLOBES AND GUARDS FOR NEW LIGHTING FIXTURES IN FORWARD ENGINE ROOM
Condition: Unknown
Due 24 October 1987
Resolved 24 October 1987
Unknown
Issued 24 October 1986 Resolved
STENCIL LOCATION OF MAIN FUEL TANK EMERGENCY EXIT IN FWD MACHINERY SPACE.
Condition: Unknown
Due 24 October 1986
Resolved 24 October 1986
Engineering
Issued 24 October 1986 Resolved
REINSTALL LAGGING ON STARBOARD MAIN ENGINE EXHAUST PIPING.
Condition: Unknown
Due 24 October 1986
Resolved 24 October 1986
Engineering
Issued 24 October 1986 Resolved
INSTALL OVERSPEED TRIPS AND LOW LUBE OIL PRESSURE SHUT DOWNS ON BOTH MAIN ENGINES.
Condition: Unknown
Due 24 October 1986
Resolved 24 October 1986
Electrical
Issued 24 October 1986 Resolved
INSTALL OVERSPEED TRIP ON STARBOARD AUX. GENERATOR.
Condition: Unknown
Due 24 October 1986
Resolved 24 October 1986
Construction/Loadline
Issued 24 October 1986 Resolved
PROVIDE FOR HYDROSTATICALLY TESTING FOR BOTH AIR RECIEVERS AND TESTING OF RELIEF VALVES.
Condition: Unknown
Due 24 October 1986
Resolved 24 October 1986
Electrical
Issued 24 October 1986 Resolved
ENCLOSE THE BACK OF THE MAIN GENERATOR SWITCHBOARD
Condition: Unknown
Due 24 October 1986
Resolved 24 October 1986
Unknown
Issued 24 October 1986 Resolved
STENCIL LOCATION OF MAIN FUEL TANK EMERGENCY SHUT OFF REACH RODS ON MAIN DECK.
Condition: Unknown
Due 24 October 1986
Resolved 24 October 1986
Unknown
Issued 24 October 1986 Resolved
REPLACE THE PLASTIC FUEL OIL DAY TANK SIGHT GLASSES WITH GLASS OF SOME OTHER SUITABLE FIRE RETARDENT MATERIAL.
Condition: Unknown
Due 24 October 1986
Resolved 24 October 1986
Fire Fighting
Issued 24 October 1986 Resolved
PROVIDE INTERNATIONAL SHORE CONNECTION.
Condition: Unknown
Due 24 October 1986
Resolved 24 October 1986
Construction/Loadline
Issued 24 October 1986 Resolved
CROP TO GOOD METAL AND RENEW FRAMES IN WAY OF BOTH MAIN SHAFT STUFFING BOXES.
Condition: Unknown
Due 24 October 1986
Resolved 24 October 1986

Casualty record · 1

27 June 2006Routine · role: Involved in a Marine Casualty · serious marine incident, as classified · 1 injured · activity 2693416
Each line is an incident investigation the Coast Guard recorded with this hull among the vessels involved, with the date and the classification the Coast Guard gave it, and the bridge, lock or dam the investigation names where it names one. Involvement is not fault. The investigation narrative is not published. Source: IIR, through 2026.

Recorded names · 1

GLACIER (2006). Names as the Coast Guard recorded them in incident records, with the years they appear; some are renames and some are spelling variants.

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.