Records from 1999 to 2014. Most recent: inspection, 12 March 2014.
A report is not offered for this hull: Its record holds only 2 of the seven kinds of material a report is built from: inspections, deficiencies, operational controls, tow-unit appearances, casualty records, dimensions and documentation. That is a statement about the record, not about the vessel. Reports.
Lifesaving › Line-Throwing Appliances › Projectiles
Issued 12 March 2014
Resolved
Replace with new expired charges for line throwing apparatus.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 18 March 2014
Resolution: Vessel operator bought new charges.
Lifesaving › Lifefloat › Float-free Link
Issued 12 March 2014
Resolved
Replace small weak link on the lifefloat with correct rated weak link for the lifefloat's size.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 18 March 2014
Resolution: Operator installed the correct weal link for the lifefloat''s size.
Lifesaving › Lifefloat › Floating Electric Waterlight
Issued 12 March 2014
Resolved
Replaced cracked waterlight on lifefloat with new.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 18 March 2014
Resolution: Operator replaced the waterlight with brand new light.
Engineering › Diesel Engine (propulsion-direct drive) › Gear/Clutch Starter (air motor)
Issued 12 March 2014
Resolved
Repair Stbd #2 main engine tachometer. It is reading the wrong direction.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 18 March 2014
Resolution: Operator provide the USCG MI with a tech report showing that the wires to the tach had been crossed and the problem was fixed.
Documentation › Certificates/Documents › Certificate of Documentation (CG-1270)
Issued 27 January 2012
Resolved
Current COD was not on board vessel
Due 28 January 2012
Resolved 27 January 2012
Resolution: COD was in the company office, placed the original on the vessel
Communications › Visual Communication › Warning Sign (gangway)
Issued 27 January 2012
Resolved
Correct PFD donning instruction was not posted.
Due 30 January 2012
Resolved 27 January 2012
Resolution: Posted placard
Fire Fighting › Fire Main › Pressure
Issued 27 January 2012
Resolved
Fire main pressure gauge not working
Due 30 January 2012
Resolved 3 February 2012
Resolution: Replaced gauge sending unit
Navigation › Piloting/Steering › Marine Charts
Issued 27 January 2012
Resolved
Charts were not updated
Due 27 February 2012
Resolved 3 February 2012
Resolution: Reeplaced with new updated charts
Construction/Loadline › Penetrations › Gasket
Issued 27 January 2012
Resolved
All water tight doors below the main deck have weather tight style soft foam gaskets
Action required: 17 - Rectify deficiencies prior to departure
Resolved 3 February 2012
Resolution: Replaced all WTD gaskets
Communications › Internal Communications System › Sound-powered Telephone
Issued 27 January 2012
Resolved
Sound powered phone system not working properly
Due 27 February 2012
Resolved 3 February 2012
Resolution: Repaired phones - test sat
Communications › Radio Communications › Emergency Source of Power
Issued 27 January 2012
Resolved
SSB radio not on battery back up power.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 3 February 2012
Resolution: Repaired - test sat
Documentation › Logs/Records › Oil Record Book
Issued 7 February 2011
Resolved
Provide current version of oil record book to vessel.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 17 February 2011
Communications › Alarms/Indicators › General Alarm
Issued 7 February 2011
Resolved
Provide general alarm on bridge that meets standards in 46 CFR sub part J.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 17 February 2011
Lifesaving › Lifejacket/PFD (General) › Lights
Issued 7 February 2011
Resolved
Provide updated lights for lifejackets, lights expired.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 17 February 2011
Lifesaving › Lifefloat › Float-free Link
Issued 9 February 2010
Resolved
Replace weak links on lifefloats; ensure tag on weak link has correct breaking strentgh.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 21 February 2010
Fire Fighting › Means of Escape › Emergency Lighting
Issued 9 February 2010
Resolved
Place emergency lighting for escape hatch at section C14.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 21 February 2010
Accommodation/Occupational Safety › Occupational Safety › Tripping/Falling Hazard
Issued 9 February 2010
Resolved
Repair step in ladder in section C14; step broken and part missing.
Action required: 705 - Other - as specified
Due 9 March 2010
Resolved 21 March 2010
Communications › Alarms/Indicators › General Alarm
Issued 9 February 2010
Resolved
Repair general alarm bell in port section of engine room.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 21 March 2010
Personnel › Manning/Qualifications › Minimum Safe Manning
Issued 9 February 2010
Resolved
Ensure chief engineer is onboard as per COI prior to sailing.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 17 February 2011
Communications › Radio Communications › Radiotelephone Transceiver (2-27.5 MHz)
Issued 27 January 2009
Resolved
Vsl's SSB is inop and
Action required: 705 - Other - as specified
Resolved 17 February 2009
Resolution: Completed radio installation.
Lifesaving › Lifefloat › Float Free
Issued 27 January 2009
Resolved
Install a float-free cradle arrangement for vsl's lifefloats.
Action required: 705 - Other - as specified
Resolved 29 January 2009
Operations/Management › Ballast Water Managment › Ballast Water Discharge
Issued 27 January 2009
Resolved
Renew vsl's ballast water suction hose and strainer assy.
Action required: 705 - Other - as specified
Resolved 29 January 2009
Deck/Cargo › Cargo Stowage › General
Issued 27 January 2009
Resolved
Properly secure portable office to main deck while onboard vessel.
Action required: 705 - Other - as specified
Resolved 29 January 2009
Construction/Loadline › Structures › Transverse Bulkhead
Issued 21 February 2007
Resolved
Provide Stop-Valves for PVC piping that penetrate Bulkheas and Decks.
Condition: Placed in Improper Service
Action required: 705 - Other - as specified
Due 21 March 2007
Resolved 23 February 2007
Resolution: Stop-valves installed on all pvs pipes.
Construction/Loadline › Structures › Machinery Space Opening
Issued 21 February 2007
Resolved
Seal all Through Bulkhead penetrations in the Machinery Spaces with CG approved items.
Condition: Placed in Improper Service
Action required: 705 - Other - as specified
Due 21 March 2007
Resolved 23 February 2007
Resolution: Penetrations sealed using Nelson Fire Stop.
Electrical › Electrical Distribution System (service) › Junction Box
Issued 21 February 2007
Resolved
Provide all permanet equipment with Power Source from a "J" box, all plug in receptacles are for temporary equipment.
Condition: Placed in Improper Service
Action required: 705 - Other - as specified
Due 21 March 2007
Resolved 23 February 2007
Resolution: All plug in rectacles changed over to "J" boxes.
Stability › Watertight Integrity › General
Issued 21 February 2007
Resolved
Provide Watertight door indicators at the operating station for all doors in bulkheads required to be watertight, IAW 46 CFR 174.
Condition: Placed in Improper Service
Action required: 705 - Other - as specified
Due 21 March 2007
Resolved 12 March 2007
Resolution: Switches installed and indicators are on the Bridge.
Documentation › Manuals/Policy Documentation › Instructions for On-board Maintenance (lifesaving)
Issued 21 February 2007
Resolved
Provide proof of Automation Tests that have been completed.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 21 March 2007
Resolved 23 February 2007
Resolution: Test results provided all SAT.
Documentation › Manuals/Policy Documentation › Instructions for On-board Maintenance (lifesaving)
Issued 21 February 2007
Resolved
Provide Automation Test Procedures for approval with Hydraulic Alarms.
Condition: Placed in Improper Service
Action required: 705 - Other - as specified
Due 21 March 2007
Resolved 23 February 2007
Resolution: Automation test provided.
Documentation › Manuals/Policy Documentation › Operations Manual (Incinerator)
Issued 21 February 2007
Resolved
Provide Bottom Surveys for the Operations Manual.
Condition: Placed in Improper Service
Action required: 705 - Other - as specified
Due 21 March 2007
Resolved 23 February 2007
Resolution: Copies from client provided and instlled in the Operations Manual.
Fire Fighting › Fire Pumps › Pressure
Issued 21 February 2007
Resolved
Demonstrate proper operation of the Stbd Fire Pump prior to sailing.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 22 February 2007
Resolved 23 February 2007
Resolution: Fire pump renewed, pressure obtained.
Lifesaving › Lifejacket/PFD (General) › Quantity
Issued 30 January 2006
Resolved
Provide three additional lifejackets at vessel operating stations.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 9 February 2006
Communications › Alarms/Indicators › Bilge Alarm
Issued 30 January 2006
Resolved
Electrical connections to all bilge alarm sensors required to be completed within a junction box.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 9 February 2006
Documentation › Safety/Response Plans/Programs › Vessel Response Plan
Issued 6 January 2006
Resolved
33U.S.C.1321(j)(G)-The vessel owner/operator did not certify that response resources are ensured by contract to respond to the maximum extent possible, to a worst case discharge.
33U.S.C.1321(j)(D)(ii)-The NTVRP does not identify a qualified individual and his/her responsibilities, including immediate contact with the NRC and the oil spill removal organization.
Due 6 February 2006
Resolved 30 July 2009
Resolution: Vessel owner/operator addressed outstanding deficiencies and amend NTVRP Control #03396 accordingly. Vessel issued Interim Operating Authorization expiring 7/30/2011.
Documentation › Safety/Response Plans/Programs › Vessel Response Plan
Issued 6 January 2006
Resolved
33U.S.C.1321(j)(D)(i)- The NTVRP does not include a list of intended areas of operation/COTP zones
33U.S.C.1321(j)(D)(iii)-The NTVRP does not identify an oil spill removal organization
33U.S.C.1321(j)(D)(iv)-The NTVRP does not address drills or an effective drill program
Due 6 February 2006
Resolved 30 July 2009
Resolution: Vessel owner/operator addressed outstanding deficiencies and amend NTVRP Control #03396 accordingly. Vessel issued Interim Operating Authorization expiring 7/30/2011.
Documentation › Safety Management System
Issued 6 April 2004
Resolved
Provide the vessel with automation test procedures and an operations manual for the automation system. LEGACY COMPONENT DESC: Conformity Maintenance Procedures
Action required: 705 - Other - as specified
Due 6 May 2004
Resolved 14 May 2004
Operations/Management › Drills/Instruction
Issued 6 April 2004
Resolved
Provide the vessel with a Lifesaving Signals and Helicopter Recovery Placard. LEGACY COMPONENT DESC: Lifesaving Signals and Helicopter Recovery Placard
Action required: 705 - Other - as specified
Due 6 May 2004
Resolved 8 April 2004
Communications › Alarms/Indicators
Issued 6 April 2004
Resolved
Provide placards for all general alarm bells. LEGACY COMPONENT DESC: General Alarm
Action required: 705 - Other - as specified
Due 6 May 2004
Resolved 8 April 2004
Navigation › Piloting/Steering
Issued 6 April 2004
Resolved
Provide the vessel with an appropriate marine compass. LEGACY COMPONENT DESC: Magnetic Compass
Action required: 17 - Rectify deficiencies prior to departure
Due 6 May 2004
Resolved 8 April 2004
Communications › Audible Communications
Issued 6 April 2004
Resolved
Provide the vessel with a PA system in accordance with 46 CFR 113.50. LEGACY COMPONENT DESC: Public Address System
Action required: 705 - Other - as specified
Due 6 May 2004
Resolved 11 May 2004
Communications › Radio Communications
Issued 6 April 2004
Resolved
Provide the vessel with another portable life boat radio for a total of (2) radios. LEGACY COMPONENT DESC: VHF Radiotelephone
Action required: 17 - Rectify deficiencies prior to departure
Due 6 May 2004
Resolved 8 April 2004
Communications › Radio Communications
Issued 6 April 2004
Resolved
Replace the hydrostatic release for the EPIRB. LEGACY COMPONENT DESC: EPIRB
Action required: 17 - Rectify deficiencies prior to departure
Due 6 May 2004
Resolved 8 April 2004
Lifesaving › Rescue Boat
Issued 6 April 2004
Resolved
Provide reflective tape for the rescue boat and stencil the capacity. LEGACY COMPONENT DESC: Markings
Action required: 17 - Rectify deficiencies prior to departure
Due 6 May 2004
Resolved 8 April 2004
Lifesaving › Lifebuoys
Issued 6 April 2004
Resolved
Provide lifelines for two ringbuoys. LEGACY COMPONENT DESC: Buoyant Lifeline
Action required: 17 - Rectify deficiencies prior to departure
Due 6 May 2004
Resolved 8 April 2004
Engineering › Fuel Oil Service System
Issued 6 April 2004
Resolved
Replace the petcocks on the RAYCOR filters with an approved type. LEGACY COMPONENT DESC: Filter
Action required: 705 - Other - as specified
Due 6 May 2004
Resolved 11 May 2004
Engineering › Compressed Air System (control)
Issued 6 April 2004
Resolved
Replace the relief valve on the air receiver. LEGACY COMPONENT DESC: Receiver/Bottle
Action required: 705 - Other - as specified
Due 6 May 2004
Resolved 8 April 2004
Stability › Watertight Integrity
Issued 6 April 2004
Resolved
Replace the gaskets on two WTH's. LEGACY COMPONENT DESC: Watertight Hatch
Action required: 17 - Rectify deficiencies prior to departure
Due 6 May 2004
Resolved 8 April 2004
Fire Fighting › Fire Pumps
Issued 6 April 2004
Resolved
Install a start/stop switch and pressure gauge in the pilothouse. LEGACY COMPONENT DESC: Arrangement
Action required: 705 - Other - as specified
Due 6 May 2004
Resolved 14 May 2004