MAMMOTH ELEVATOR

MAMMOTH ELEVATOR is a 1998 offshore supply vessel. The Coast Guard has recorded 17 inspections since 1999, most recently in March 2014, along with 48 deficiencies.

Records from 1999 to 2014. Most recent: inspection, 12 March 2014.

Built
1998
Last inspected
12 March 2014
Documentation
Expired · documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

8767604 View on MarineTraffic leaves Maury; a third-party site, nothing from it is stored here
WDA7929
480102
Flag
UNITED STATES
366848740 (licence lapsed)
Maury page id
psix-480102

Inspections, by type

…with no type recorded2
Years with a record 14 calendar years (1999–2014)
The 17 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

This record may be incomplete: the most recent inspection recorded for this vessel was 12 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Offshore class in Maury's sources begin in 1978.

Documentation record

Registered dimensions (L × B × D)144.0 ft × 65.0 ft × 9.0 ft
Registered tonnagegross 499 / net 339
ITC dimensions (L × B × D)144.0 ft × 65.0 ft × 9.0 ft
ITC tonnagegross 922 / net 276
BuilderELEVATING BOATS INC · HOUMA, LA, UNITED STATES · built 1998
Hull materialSteel
PropulsionDiesel Reduction
Hull shapeNot recorded
Hull configurationNot recorded
Hailing portHOUMA, LA
Trade endorsementsCoastwise, unrestricted
DocumentationExpired · issued 30 June 2004
Service, as the file records itOffshore Supply Vessel
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it339 - Regulatory (Subpart C or D), Net Ton
276 - Convention (Subpart B), Net Ton
499 - Regulatory (Subpart C or D), Gross Ton
922 - Convention (Subpart B), Gross Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 September 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.

Radio station licence

WDA7929MMSI 366848740 · expired · compulsorily equipped · granted 14 April 2012, cancelled 25 June 2022
FCC Universal Licensing System ship-station file of 6 September 2026, matched to this hull on its US Official Number. Status and dates are the file’s own. The licensee is not read from the file and is not shown. A lapsed licence’s MMSI is still the number the vessel transmitted under while it was valid.

A report is not offered for this hull: Its record holds only 2 of the seven kinds of material a report is built from: inspections, deficiencies, operational controls, tow-unit appearances, casualty records, dimensions and documentation. That is a statement about the record, not about the vessel. Reports.

Inspection history · 17

12 March 2014 Deficiency Check · Administrative Inspection · Annual Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 4814233
27 January 2012 Annual Inspection · Deficiency Check
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 4232107
7 February 2011 Internal Structural Exam · Hull Examination · Examination of Repairs · Annual Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 3939446
9 February 2010 Re-Inspection · MTSA Verification
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 3676255
27 January 2009 Deficiency Check · Re-Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 3400740
22 October 2008 Administrative Inspection
Administrative · Commandant (CG-CVC) · Activity 3349442
7 February 2008 COI Inspection · Internal Structural Exam · Administrative Inspection · Hull Examination · Examination of Repairs
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 3143445
21 February 2007 Re-Inspection · Deficiency Check
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 2874907
18 August 2006 Security Plan Amendment Review - VSP
Administrative · Marine Safety Center (MSC) · Activity 2752277
30 January 2006 Re-Inspection · Hull Examination
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 2575789
20 January 2005 MTSA Verification · Re-Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 2306194
26 April 2004 Security Plan Review - VSP
Administrative · Marine Safety Center (MSC) · Activity 2052913
6 April 2004 Re-Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 2038278
14 March 2003 Initial Certification · Initial Construction-Excluding Oversight · Inclining Experiment
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 1831063
31 October 2001 Inclining Experiment
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 773069
31 July 2000 Type not recorded
No type recorded · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 821327
30 June 1999 Type not recorded
No type recorded · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 808268

Deficiency record · 48

Lifesaving › Line-Throwing Appliances › Projectiles
Issued 12 March 2014 Resolved
Replace with new expired charges for line throwing apparatus.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 18 March 2014
Resolution: Vessel operator bought new charges.
Lifesaving › Lifefloat › Float-free Link
Issued 12 March 2014 Resolved
Replace small weak link on the lifefloat with correct rated weak link for the lifefloat's size.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 18 March 2014
Resolution: Operator installed the correct weal link for the lifefloat''s size.
Lifesaving › Lifefloat › Floating Electric Waterlight
Issued 12 March 2014 Resolved
Replaced cracked waterlight on lifefloat with new.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 18 March 2014
Resolution: Operator replaced the waterlight with brand new light.
Engineering › Diesel Engine (propulsion-direct drive) › Gear/Clutch Starter (air motor)
Issued 12 March 2014 Resolved
Repair Stbd #2 main engine tachometer. It is reading the wrong direction.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 18 March 2014
Resolution: Operator provide the USCG MI with a tech report showing that the wires to the tach had been crossed and the problem was fixed.
Documentation › Certificates/Documents › Certificate of Documentation (CG-1270)
Issued 27 January 2012 Resolved
Current COD was not on board vessel
Due 28 January 2012
Resolved 27 January 2012
Resolution: COD was in the company office, placed the original on the vessel
Communications › Visual Communication › Warning Sign (gangway)
Issued 27 January 2012 Resolved
Correct PFD donning instruction was not posted.
Due 30 January 2012
Resolved 27 January 2012
Resolution: Posted placard
Fire Fighting › Fire Main › Pressure
Issued 27 January 2012 Resolved
Fire main pressure gauge not working
Due 30 January 2012
Resolved 3 February 2012
Resolution: Replaced gauge sending unit
Navigation › Piloting/Steering › Marine Charts
Issued 27 January 2012 Resolved
Charts were not updated
Due 27 February 2012
Resolved 3 February 2012
Resolution: Reeplaced with new updated charts
Construction/Loadline › Penetrations › Gasket
Issued 27 January 2012 Resolved
All water tight doors below the main deck have weather tight style soft foam gaskets
Action required: 17 - Rectify deficiencies prior to departure
Resolved 3 February 2012
Resolution: Replaced all WTD gaskets
Communications › Internal Communications System › Sound-powered Telephone
Issued 27 January 2012 Resolved
Sound powered phone system not working properly
Due 27 February 2012
Resolved 3 February 2012
Resolution: Repaired phones - test sat
Communications › Radio Communications › Emergency Source of Power
Issued 27 January 2012 Resolved
SSB radio not on battery back up power.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 3 February 2012
Resolution: Repaired - test sat
Documentation › Logs/Records › Oil Record Book
Issued 7 February 2011 Resolved
Provide current version of oil record book to vessel.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 17 February 2011
Communications › Alarms/Indicators › General Alarm
Issued 7 February 2011 Resolved
Provide general alarm on bridge that meets standards in 46 CFR sub part J.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 17 February 2011
Lifesaving › Lifejacket/PFD (General) › Lights
Issued 7 February 2011 Resolved
Provide updated lights for lifejackets, lights expired.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 17 February 2011
Lifesaving › Lifefloat › Float-free Link
Issued 9 February 2010 Resolved
Replace weak links on lifefloats; ensure tag on weak link has correct breaking strentgh.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 21 February 2010
Fire Fighting › Means of Escape › Emergency Lighting
Issued 9 February 2010 Resolved
Place emergency lighting for escape hatch at section C14.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 21 February 2010
Accommodation/Occupational Safety › Occupational Safety › Tripping/Falling Hazard
Issued 9 February 2010 Resolved
Repair step in ladder in section C14; step broken and part missing.
Action required: 705 - Other - as specified
Due 9 March 2010
Resolved 21 March 2010
Communications › Alarms/Indicators › General Alarm
Issued 9 February 2010 Resolved
Repair general alarm bell in port section of engine room.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 21 March 2010
Personnel › Manning/Qualifications › Minimum Safe Manning
Issued 9 February 2010 Resolved
Ensure chief engineer is onboard as per COI prior to sailing.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 17 February 2011
Communications › Radio Communications › Radiotelephone Transceiver (2-27.5 MHz)
Issued 27 January 2009 Resolved
Vsl's SSB is inop and
Action required: 705 - Other - as specified
Resolved 17 February 2009
Resolution: Completed radio installation.
Lifesaving › Lifefloat › Float Free
Issued 27 January 2009 Resolved
Install a float-free cradle arrangement for vsl's lifefloats.
Action required: 705 - Other - as specified
Resolved 29 January 2009
Operations/Management › Ballast Water Managment › Ballast Water Discharge
Issued 27 January 2009 Resolved
Renew vsl's ballast water suction hose and strainer assy.
Action required: 705 - Other - as specified
Resolved 29 January 2009
Deck/Cargo › Cargo Stowage › General
Issued 27 January 2009 Resolved
Properly secure portable office to main deck while onboard vessel.
Action required: 705 - Other - as specified
Resolved 29 January 2009
Construction/Loadline › Structures › Transverse Bulkhead
Issued 21 February 2007 Resolved
Provide Stop-Valves for PVC piping that penetrate Bulkheas and Decks.
Condition: Placed in Improper Service
Action required: 705 - Other - as specified
Due 21 March 2007
Resolved 23 February 2007
Resolution: Stop-valves installed on all pvs pipes.
Construction/Loadline › Structures › Machinery Space Opening
Issued 21 February 2007 Resolved
Seal all Through Bulkhead penetrations in the Machinery Spaces with CG approved items.
Condition: Placed in Improper Service
Action required: 705 - Other - as specified
Due 21 March 2007
Resolved 23 February 2007
Resolution: Penetrations sealed using Nelson Fire Stop.
Electrical › Electrical Distribution System (service) › Junction Box
Issued 21 February 2007 Resolved
Provide all permanet equipment with Power Source from a "J" box, all plug in receptacles are for temporary equipment.
Condition: Placed in Improper Service
Action required: 705 - Other - as specified
Due 21 March 2007
Resolved 23 February 2007
Resolution: All plug in rectacles changed over to "J" boxes.
Stability › Watertight Integrity › General
Issued 21 February 2007 Resolved
Provide Watertight door indicators at the operating station for all doors in bulkheads required to be watertight, IAW 46 CFR 174.
Condition: Placed in Improper Service
Action required: 705 - Other - as specified
Due 21 March 2007
Resolved 12 March 2007
Resolution: Switches installed and indicators are on the Bridge.
Documentation › Manuals/Policy Documentation › Instructions for On-board Maintenance (lifesaving)
Issued 21 February 2007 Resolved
Provide proof of Automation Tests that have been completed.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 21 March 2007
Resolved 23 February 2007
Resolution: Test results provided all SAT.
Documentation › Manuals/Policy Documentation › Instructions for On-board Maintenance (lifesaving)
Issued 21 February 2007 Resolved
Provide Automation Test Procedures for approval with Hydraulic Alarms.
Condition: Placed in Improper Service
Action required: 705 - Other - as specified
Due 21 March 2007
Resolved 23 February 2007
Resolution: Automation test provided.
Documentation › Manuals/Policy Documentation › Operations Manual (Incinerator)
Issued 21 February 2007 Resolved
Provide Bottom Surveys for the Operations Manual.
Condition: Placed in Improper Service
Action required: 705 - Other - as specified
Due 21 March 2007
Resolved 23 February 2007
Resolution: Copies from client provided and instlled in the Operations Manual.
Fire Fighting › Fire Pumps › Pressure
Issued 21 February 2007 Resolved
Demonstrate proper operation of the Stbd Fire Pump prior to sailing.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 22 February 2007
Resolved 23 February 2007
Resolution: Fire pump renewed, pressure obtained.
Lifesaving › Lifejacket/PFD (General) › Quantity
Issued 30 January 2006 Resolved
Provide three additional lifejackets at vessel operating stations.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 9 February 2006
Communications › Alarms/Indicators › Bilge Alarm
Issued 30 January 2006 Resolved
Electrical connections to all bilge alarm sensors required to be completed within a junction box.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 9 February 2006
Documentation › Safety/Response Plans/Programs › Vessel Response Plan
Issued 6 January 2006 Resolved
33U.S.C.1321(j)(G)-The vessel owner/operator did not certify that response resources are ensured by contract to respond to the maximum extent possible, to a worst case discharge. 33U.S.C.1321(j)(D)(ii)-The NTVRP does not identify a qualified individual and his/her responsibilities, including immediate contact with the NRC and the oil spill removal organization.
Due 6 February 2006
Resolved 30 July 2009
Resolution: Vessel owner/operator addressed outstanding deficiencies and amend NTVRP Control #03396 accordingly. Vessel issued Interim Operating Authorization expiring 7/30/2011.
Documentation › Safety/Response Plans/Programs › Vessel Response Plan
Issued 6 January 2006 Resolved
33U.S.C.1321(j)(D)(i)- The NTVRP does not include a list of intended areas of operation/COTP zones 33U.S.C.1321(j)(D)(iii)-The NTVRP does not identify an oil spill removal organization 33U.S.C.1321(j)(D)(iv)-The NTVRP does not address drills or an effective drill program
Due 6 February 2006
Resolved 30 July 2009
Resolution: Vessel owner/operator addressed outstanding deficiencies and amend NTVRP Control #03396 accordingly. Vessel issued Interim Operating Authorization expiring 7/30/2011.
Documentation › Safety Management System
Issued 6 April 2004 Resolved
Provide the vessel with automation test procedures and an operations manual for the automation system. LEGACY COMPONENT DESC: Conformity Maintenance Procedures
Action required: 705 - Other - as specified
Due 6 May 2004
Resolved 14 May 2004
Operations/Management › Drills/Instruction
Issued 6 April 2004 Resolved
Provide the vessel with a Lifesaving Signals and Helicopter Recovery Placard. LEGACY COMPONENT DESC: Lifesaving Signals and Helicopter Recovery Placard
Action required: 705 - Other - as specified
Due 6 May 2004
Resolved 8 April 2004
Communications › Alarms/Indicators
Issued 6 April 2004 Resolved
Provide placards for all general alarm bells. LEGACY COMPONENT DESC: General Alarm
Action required: 705 - Other - as specified
Due 6 May 2004
Resolved 8 April 2004
Navigation › Piloting/Steering
Issued 6 April 2004 Resolved
Provide the vessel with an appropriate marine compass. LEGACY COMPONENT DESC: Magnetic Compass
Action required: 17 - Rectify deficiencies prior to departure
Due 6 May 2004
Resolved 8 April 2004
Communications › Audible Communications
Issued 6 April 2004 Resolved
Provide the vessel with a PA system in accordance with 46 CFR 113.50. LEGACY COMPONENT DESC: Public Address System
Action required: 705 - Other - as specified
Due 6 May 2004
Resolved 11 May 2004
Communications › Radio Communications
Issued 6 April 2004 Resolved
Provide the vessel with another portable life boat radio for a total of (2) radios. LEGACY COMPONENT DESC: VHF Radiotelephone
Action required: 17 - Rectify deficiencies prior to departure
Due 6 May 2004
Resolved 8 April 2004
Communications › Radio Communications
Issued 6 April 2004 Resolved
Replace the hydrostatic release for the EPIRB. LEGACY COMPONENT DESC: EPIRB
Action required: 17 - Rectify deficiencies prior to departure
Due 6 May 2004
Resolved 8 April 2004
Lifesaving › Rescue Boat
Issued 6 April 2004 Resolved
Provide reflective tape for the rescue boat and stencil the capacity. LEGACY COMPONENT DESC: Markings
Action required: 17 - Rectify deficiencies prior to departure
Due 6 May 2004
Resolved 8 April 2004
Lifesaving › Lifebuoys
Issued 6 April 2004 Resolved
Provide lifelines for two ringbuoys. LEGACY COMPONENT DESC: Buoyant Lifeline
Action required: 17 - Rectify deficiencies prior to departure
Due 6 May 2004
Resolved 8 April 2004
Engineering › Fuel Oil Service System
Issued 6 April 2004 Resolved
Replace the petcocks on the RAYCOR filters with an approved type. LEGACY COMPONENT DESC: Filter
Action required: 705 - Other - as specified
Due 6 May 2004
Resolved 11 May 2004
Engineering › Compressed Air System (control)
Issued 6 April 2004 Resolved
Replace the relief valve on the air receiver. LEGACY COMPONENT DESC: Receiver/Bottle
Action required: 705 - Other - as specified
Due 6 May 2004
Resolved 8 April 2004
Stability › Watertight Integrity
Issued 6 April 2004 Resolved
Replace the gaskets on two WTH's. LEGACY COMPONENT DESC: Watertight Hatch
Action required: 17 - Rectify deficiencies prior to departure
Due 6 May 2004
Resolved 8 April 2004
Fire Fighting › Fire Pumps
Issued 6 April 2004 Resolved
Install a start/stop switch and pressure gauge in the pilothouse. LEGACY COMPONENT DESC: Arrangement
Action required: 705 - Other - as specified
Due 6 May 2004
Resolved 14 May 2004

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.