OAK GROVE is a 1953 freight ship. The Coast Guard has recorded 26 inspections since 1984, most recently in September 1998, along with 20 deficiencies.

Records from 1984 to 1998. Most recent: inspection, 10 September 1998.

Built
1953
Last inspected
10 September 1998
Documentation
Not in the documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

WYP9240
Flag
UNITED STATES
—
Maury page id
psix-48016

Inspections, by type

…with no type recorded9
Years with a record 14 calendar years (1984–1998)
The 26 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

This record may be incomplete: the most recent inspection recorded for this vessel was 28 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the General Dry Cargo Ship class in Maury's sources begin in 1980.

Documentation record

Tonnage as PSIX records it43 - Regulatory (Subpart C or D), Gross Ton
29 - Regulatory (Subpart C or D), Net Ton
This hull's Official Number is not in the NVDC file dated 10 September 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.

Radio station licence

No FCC ship-station licence is recorded against this Official Number in the file of 6 September 2026. That is a fact about the licence file, not about the radio.

A report is not offered for this hull: Its record holds only 2 of the seven kinds of material a report is built from: inspections, deficiencies, operational controls, tow-unit appearances, casualty records, dimensions and documentation. That is a statement about the record, not about the vessel. Reports.

Inspection history · 26

10 September 1998 Administrative
Administrative · MSO BUFFALO · USCG Great Lakes District (CGD-GL) · Activity 799161
25 April 1997 Hull Examination · COI Inspection
Physical examination · MSO BUFFALO · USCG Great Lakes District (CGD-GL) · Activity 1456474
26 April 1996 COI Inspection
Physical examination · MSO BUFFALO · USCG Great Lakes District (CGD-GL) · Activity 1367722
14 August 1995 Type not recorded
No type recorded · MSO BUFFALO · USCG Great Lakes District (CGD-GL) · Activity 870807
2 June 1995 Deficiency Check
Physical examination · MSO BUFFALO · USCG Great Lakes District (CGD-GL) · Activity 874823
25 April 1995 Re-Inspection
Physical examination · MSO BUFFALO · USCG Great Lakes District (CGD-GL) · Activity 1367358
28 April 1994 COI Inspection
Physical examination · MSO BUFFALO · USCG Great Lakes District (CGD-GL) · Activity 1451935
25 May 1993 Re-Inspection
Physical examination · MSO BUFFALO · USCG Great Lakes District (CGD-GL) · Activity 1358078
24 June 1992 Deficiency Check
Physical examination · MSO BUFFALO · USCG Great Lakes District (CGD-GL) · Activity 1269678
20 March 1992 Hull Examination · Re-Inspection
Physical examination · MSO BUFFALO · USCG Great Lakes District (CGD-GL) · Activity 1354126
22 April 1991 COI Inspection
Physical examination · MSO BUFFALO · USCG Great Lakes District (CGD-GL) · Activity 1230379
17 May 1989 Re-Inspection
Physical examination · MSO BUFFALO · USCG Great Lakes District (CGD-GL) · Activity 1204216
10 May 1988 COI Inspection
Physical examination · MSO BUFFALO · USCG Great Lakes District (CGD-GL) · Activity 1351029
14 July 1987 Re-Inspection
Physical examination · MSO BUFFALO · USCG Great Lakes District (CGD-GL) · Activity 1017942
11 June 1987 Type not recorded
No type recorded · MSO BUFFALO · USCG Great Lakes District (CGD-GL) · Activity 1030183
28 May 1987 Type not recorded
No type recorded · MSO BUFFALO · USCG Great Lakes District (CGD-GL) · Activity 1337139
15 April 1987 Hull Examination
Physical examination · MSO BUFFALO · USCG Great Lakes District (CGD-GL) · Activity 1336999
1 April 1987 Type not recorded
No type recorded · MSO BUFFALO · USCG Great Lakes District (CGD-GL) · Activity 1317242
15 March 1987 Type not recorded
No type recorded · MSO BUFFALO · USCG Great Lakes District (CGD-GL) · Activity 1019460
15 March 1987 Type not recorded
No type recorded · MSO BUFFALO · USCG Great Lakes District (CGD-GL) · Activity 1324126
27 February 1987 Administrative
Administrative · MSO BUFFALO · USCG Great Lakes District (CGD-GL) · Activity 1002472
17 February 1987 Type not recorded
No type recorded · MSO BUFFALO · USCG Great Lakes District (CGD-GL) · Activity 1325982
4 February 1987 Type not recorded
No type recorded · MSO BUFFALO · USCG Great Lakes District (CGD-GL) · Activity 1313443
2 July 1986 COI Inspection
Physical examination · MSO BUFFALO · USCG Great Lakes District (CGD-GL) · Activity 1309260
19 August 1985 Re-Inspection
Physical examination · MSO BUFFALO · USCG Great Lakes District (CGD-GL) · Activity 989328
2 July 1984 Type not recorded
No type recorded · MSO BUFFALO · USCG Great Lakes District (CGD-GL) · Activity 986086

Deficiency record · 20

Construction/Loadline
Issued 25 April 1997 Resolved
MAKE PERMANENT REPAIRS TO HULL BOTTOM PLATING AND RELATED INTERNAL STRUCTURES IN WAY OF #1 AND #2 BOTTOM VOIDS, TO BE COMPLETED PRIOR TO THE COMPLIANCE DATE. UNTIL COMPLETE, MONITOR CONDITIONS AND REPORT ANY WORSENING OF DAMAGES OR WATER INGRESS IMMEDIATELY TO THE OCMI.
Condition: Unknown
Due 25 April 1997
Resolved 25 April 1997
Engineering
Issued 25 April 1997 Resolved
REPAIR AND PROVE PROPER OPERATION OF STARBOARD REMOTE FUEL STOP. CORRECTEDON SPOT.
Condition: Unknown
Due 5 May 1997
Resolved 5 May 1997
Electrical
Issued 25 April 1997 Resolved
CLEAN AND TIGHTEN BATTERY TERMINALS ON MAIN STARTING/GENERAL SERVICE BATTERIES. CORRECTED ON SPOT
Condition: Unknown
Due 5 May 1997
Resolved 5 May 1997
Lifesaving
Issued 25 April 1997 Resolved
2 PFD LIGHTS INOPERABLE, CORRECTED ON SPOT.
Condition: Unknown
Due 5 May 1997
Resolved 5 May 1997
Electrical
Issued 26 April 1996 Resolved
BUNDLE AND SECURE WIRING AND ELECTRICAL CABLING IN WAY OF STEERING CHAIN/SPROCKET SYSTEM AND REMOVE JURY RIGGED PORTABLE LIGHTING FIXTURES FROM ENGINEROOM.
Condition: Unknown
Due 8 May 1996
Resolved 8 May 1996
Electrical
Issued 26 April 1996 Resolved
REMOVE CORROSION FROM ELECTRICAL TERMINALS AND TIGHTEN CONNECTION WITHIN THE MAIN POWER PANEL.
Condition: Unknown
Due 8 May 1996
Resolved 8 May 1996
Electrical
Issued 26 April 1996 Resolved
CLEAN AND TIGHTEN ENGINE STARTING BATTERY CONNECTIONS AND STARTER MOTOR CONNECTIONS.
Condition: Unknown
Due 8 May 1996
Resolved 8 May 1996
Lifesaving
Issued 25 April 1995 Resolved
PROVIDE PFD DONNING INSTRUCTIONAL PLACARD.
Condition: Unknown
Due 25 April 1995
Resolved 25 April 1995
Electrical
Issued 25 April 1995 Resolved
REMOVE OR OTHERWISE PROPERLY DEAD END LOOSE WIRES AT STEERING CONSOLE ELECTRICAL PANEL.
Condition: Unknown
Due 25 April 1995
Resolved 25 April 1995
Engineering
Issued 25 April 1995 Resolved
PROVIDE STARBOARD FUEL TANK VENT FLAME SCREEN.
Condition: Unknown
Due 25 April 1995
Resolved 25 April 1995
Fire Fighting
Issued 25 April 1995 Resolved
HAVE FIRE EXTINGUISHERS RECEIVE 6-YEAR SERVICING.
Condition: Unknown
Due 25 April 1995
Resolved 25 April 1995
Fire Fighting
Issued 28 April 1994 Resolved
Verify weight of CO2 extinguisher.
Condition: Unknown
Due 28 April 1994
Resolved 28 April 1994
Construction/Loadline
Issued 28 April 1994 Resolved
rewire 12 volt bilge pump in E/R to include hard wired on/off switch and circuit protection.
Condition: Unknown
Due 28 April 1994
Resolved 28 April 1994
Lifesaving
Issued 25 May 1993 Resolved
Provide Employee Assistance Program as part of Drug testing proceedures.
Condition: Unknown
Due 25 May 1993
Resolved 25 May 1993
Documentation
Issued 20 March 1992 Resolved
Post emergency check off list._x001C_
Condition: Unknown
Due 20 March 1992
Resolved 20 March 1992
Engineering
Issued 20 March 1992 Resolved
Install MDE emergency F/O cutouts in accordance with approved plans.
Condition: Unknown
Due 20 March 1992
Resolved 20 March 1992
Deck/Cargo
Issued 20 March 1992 Resolved
Provide a 65 pound standard or 35 pound hi-tensile anchor.
Condition: Unknown
Due 20 March 1992
Resolved 20 March 1992
Lifesaving
Issued 20 March 1992 Resolved
Provide an alarm to indicate the loss of cooling water to the exhaust (46 CFR 182.15-15(b)(5).
Condition: Unknown
Due 20 March 1992
Resolved 20 March 1992
Engineering
Issued 20 March 1992 Resolved
Submit plans for F/O cutouts for MDE.
Condition: Unknown
Due 20 March 1992
Resolved 20 March 1992
Lifesaving
Issued 28 May 1987 Resolved
ROUTE RESTRICTED TO WATER DEPTH OF 140FT OR LESS UNTIL FLOAT FREE LINK IS ATTACHED TO SEAPAINTER.
Condition: Unknown
Due 28 May 1987
Resolved 28 May 1987

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.