MAURY USCG vessel records Sign in
← All vessels

SOUTHERN SPORT

SOUTHERN SPORT is a 1974 passenger vessel (inspected). The Coast Guard has recorded 64 inspections since 1981, most recently in July 2003, along with 91 deficiencies.

Records from 1981 to 2003. Most recent: inspection, 30 July 2003.

Built
1974
Last inspected
30 July 2003
Documentation
Not in the documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

WDD3642
Flag
UNITED STATES
367134270 (licence lapsed)
Maury page id
psix-48025

Inspections, by type

…with no type recorded15
Years with a record 23 calendar years (1981–2003)
The 64 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

This record may be incomplete: the most recent inspection recorded for this vessel was 23 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Passenger Ship class in Maury's sources begin in 1977.

Documentation record

Tonnage as PSIX records it95 - Regulatory (Subpart C or D), Gross Ton
191 - Convention (Subpart B), Gross Ton
65 - Regulatory (Subpart C or D), Net Ton
57 - Convention (Subpart B), Net Ton
This hull's Official Number is not in the NVDC file dated 10 September 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.

Radio station licence

WDD3642MMSI 367134270 · expired · compulsorily equipped · granted 11 August 2006, cancelled 15 October 2016
WCY9772MMSI not assigned · expired · compulsorily equipped · granted 8 April 1999, cancelled 13 June 2009 · licensed under a name not among this hull’s recorded names (not shown)
WCQ2183MMSI not assigned · expired · compulsorily equipped · granted 23 February 1995, cancelled 30 April 2005 · licensed under a name not among this hull’s recorded names (not shown)
FCC Universal Licensing System ship-station file of 6 September 2026, matched to this hull on its US Official Number. Status and dates are the file’s own. The licensee is not read from the file and is not shown. A lapsed licence’s MMSI is still the number the vessel transmitted under while it was valid.

A report is not offered for this hull: Its record holds only 2 of the seven kinds of material a report is built from: inspections, deficiencies, operational controls, tow-unit appearances, casualty records, dimensions and documentation. That is a statement about the record, not about the vessel. Reports.

Inspection history · 64

30 July 2003 Administrative Inspection
Administrative · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1862098
21 December 2002 Type not recorded
No type recorded · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1740360
22 April 2002 Hull Examination
Physical examination · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 1607877
14 February 2002 Deficiency Check
Physical examination · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 1624276
29 January 2002 Re-Inspection
Physical examination · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 1482590
26 June 2001 Examination of Repairs · Deficiency Check · Damage Survey
Physical examination · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 772122
13 June 2001 Type not recorded
No type recorded · Marine Safety Unit Victoria · USCG Heartland District (CGD-H) · Activity 160001
13 June 2001 Damage Survey
Physical examination · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 1066200
26 January 2001 Type not recorded
No type recorded · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 214719
26 January 2001 COI Inspection
Physical examination · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 1466749
18 October 2000 Damage Survey
Physical examination · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 1464325
30 May 2000 Deficiency Check
Physical examination · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 819026
25 April 2000 Hull Examination
Physical examination · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 1404962
20 April 2000 Type not recorded
No type recorded · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 729425
24 March 2000 Re-Inspection
Physical examination · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 1381869
13 March 2000 Type not recorded
No type recorded · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 217186
13 October 1999 Deficiency Check
Physical examination · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 797433
29 April 1999 Deficiency Check
Physical examination · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 792562
23 April 1999 Deficiency Check
Physical examination · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 792334
26 March 1999 Re-Inspection
Physical examination · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 1472348
21 April 1998 Hull Examination
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1462649
28 January 1998 COI Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1383821
24 March 1997 Type not recorded
No type recorded · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 771027
18 March 1997 Type not recorded
No type recorded · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 196944
15 August 1996 COI Inspection
Physical examination · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1398522
24 May 1996 Damage Survey · Examination of Repairs
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1468810
6 May 1996 Damage Survey
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1454325
4 May 1996 Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 7800
29 April 1996 Hull Examination
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1385687
2 February 1996 Deficiency Check
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 872180
18 January 1996 Administrative
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1184028
29 November 1995 Deficiency Check
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1192625
27 September 1995 Administrative
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 882689
18 August 1995 COI Inspection · Deadweight Survey
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1414484
30 November 1994 Administrative
Administrative · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1177982
25 July 1994 Administrative
Administrative · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 866432
9 June 1994 COI Inspection
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1385249
24 May 1994 Deficiency Check
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1170340
28 April 1994 COI Inspection · Hull Examination
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1432800
17 February 1994 Administrative
Administrative · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 854119
6 May 1993 COI Inspection
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1423777
7 May 1992 Hull Examination · COI Inspection
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1260354
10 October 1991 Drydock Extension
Administrative · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 935332
28 May 1991 Deficiency Check
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 906761
9 May 1991 COI Inspection
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 914971
17 May 1990 COI Inspection · Deficiency Check
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 931191
8 May 1990 Administrative
Administrative · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1234981
3 May 1990 Hull Examination
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 906525
21 December 1989 Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1225562
18 August 1989 Administrative
Administrative · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1198371
15 June 1989 COI Inspection
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1341089
28 June 1988 Deficiency Check
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 897277
16 June 1988 COI Inspection · Hull Examination
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 890994
7 December 1987 Administrative
Administrative · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1308178
26 June 1987 Administrative
Administrative · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1317009
23 June 1987 Type not recorded
No type recorded · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1336873
18 June 1987 COI Inspection
Physical examination · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1335091
24 June 1986 COI Inspection · Credit Drydock
Physical examination · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 991495
9 January 1986 Type not recorded
No type recorded · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1295987
27 June 1985 COI Inspection
Physical examination · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 981560
5 July 1984 Type not recorded
No type recorded · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1286740
7 July 1983 Type not recorded
No type recorded · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1272296
8 July 1982 Type not recorded
No type recorded · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1277499
14 July 1981 Type not recorded
No type recorded · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1276902

Deficiency record · 91

Construction/Loadline › Hull
Issued 22 April 2002 Resolved
Crop and renew bottom plating where pitted from shaft lof to stern.
Due 23 May 2002
Resolved 30 April 2002
Construction/Loadline › Hull
Issued 22 April 2002 Resolved
Crop and renew sideshell plating where clad welded IWO stbd side of engine room. LEGACY COMPONENT DESC: Hull Plating
Due 23 May 2002
Resolved 30 April 2002
Construction/Loadline › Structures
Issued 22 April 2002 Resolved
Repair identified fractures in forepeak tank.
Due 23 May 2002
Resolved 30 April 2002
Construction/Loadline › Structures
Issued 22 April 2002 Resolved
Repair fracture on third sideshell longitudinal frame at #16 transverse frame stbd side aft.
Due 23 May 2002
Resolved 30 April 2002
Construction/Loadline › Hull
Issued 22 April 2002 Resolved
Crop and renew port and starboard stern wraparounds.
Due 23 May 2002
Resolved 30 April 2002
Construction/Loadline › Structures › Ventilators
Issued 22 April 2002 Resolved
Reweld generator room vent port side main deck.
Due 23 May 2002
Resolved 30 April 2002
Construction/Loadline › Hull
Issued 22 April 2002 Resolved
Renew main deck framing member on port side (#1) in steering gear room.
Due 23 May 2002
Resolved 30 April 2002
Electrical › Electrical Distribution System (service) › Wiring
Issued 22 April 2002 Resolved
Clean up electrical wiring and install covers for all electricakl equipment in duct space.
Due 23 May 2002
Resolved 30 April 2002
Electrical › Electrical Distribution System (service) › Wiring
Issued 22 April 2002 Resolved
Install fixed receptacle for TV in lounge and remove existing extension cord.
Due 23 May 2002
Resolved 30 April 2002
Electrical › Lighting (service) › Lighting Fixture
Issued 22 April 2002 Resolved
Provide guards for glass globes for light fixtures in engine room.
Due 23 May 2002
Resolved 30 April 2002
Electrical › Electrical Distribution System (emergency) › Wiring
Issued 22 April 2002 Resolved
Rewire and install junction box for bilge alarm in engine room.
Due 23 May 2002
Resolved 30 April 2002
Engineering
Issued 22 April 2002 Resolved
Replace bolt for sea strainer (stbd) for main engine.
Due 23 May 2002
Resolved 30 April 2002
Engineering › Fuel Oil Storage/Transfer System
Issued 22 April 2002 Resolved
Properly secure fuel oil emergency shut off reach rods to valve handles.
Due 24 April 2002
Resolved 24 April 2002
Engineering
Issued 22 April 2002 Resolved
Properly secure forepeak reach rod to valve handle.
Due 24 April 2002
Resolved 24 April 2002
Fire Fighting › Fire Main
Issued 22 April 2002 Resolved
Install bracket to secure firemain on port side of engine room.
Due 23 May 2002
Resolved 30 April 2002
Fire Fighting › Portable CO2 Fire Extinguisher
Issued 22 April 2002 Resolved
Reservice fire extinguishers in captain's cabin and galley.
Due 24 April 2002
Resolved 24 April 2002
Lifesaving › Buoyant Apparatus
Issued 22 April 2002 Resolved
Renew unidentifiable weak link for lifefloat.
Due 23 May 2002
Resolved 30 April 2002
Accommodation/Occupational Safety
Issued 22 April 2002 Resolved
Re-stencil emergency escapes in galley and generator room.
Due 23 May 2002
Resolved 30 April 2002
Engineering › Steering Gear System
Issued 22 April 2002 Resolved
Repair steering gear jockey bar, ram mounting brackets, and reweld fractures in rudderpost stiffeners.
Due 30 May 2002
Resolved 30 April 2002
Engineering
Issued 22 April 2002 Resolved
Repair housing for port ventilator in engine room.
Due 23 May 2002
Resolved 30 April 2002
Construction/Loadline › Hull
Issued 29 January 2002 Resolved
Repair fractured welds as marked in way of forepeak, starboard water heater compartment and lazerette. LEGACY COMPONENT DESC: Longitudinal Frame
Condition: Unknown
Due 28 February 2002
Resolved 14 February 2002
Construction/Loadline › Hull
Issued 29 January 2002 Resolved
Drill stop & weld fracture in way of forepeak port side insert at 5th longitudinal. Weld backside of insert perimeter. LEGACY COMPONENT DESC: Side Shell
Condition: Improper Installation
Due 14 February 2002
Resolved 14 February 2002
Electrical › Electrical Distribution System (service)
Issued 29 January 2002 Resolved
Properly dead end or connect electrical wiring underneath pilothouse steering console. LEGACY COMPONENT DESC: Wiring
Condition: Improper/Lack of Maintenance
Due 28 February 2002
Resolved 14 February 2002
Engineering
Issued 29 January 2002 Resolved
Double clamp flexible hoses in way of aft lube oil tank fill, port main and starboard generator LEGACY COMPONENT DESC: flexible hoses
Condition: Improper Installation
Due 28 February 2002
Resolved 14 February 2002
Communications › Audible Communications
Issued 29 January 2002 Resolved
Install public address system in accordance with 46 CFR 184.610. LEGACY COMPONENT DESC: Public Address System
Due 28 February 2002
Resolved 14 February 2002
Engineering › Generator (propulsion-electric)
Issued 29 January 2002 Resolved
Repair and demonstrate proper operation of port & starboard generator overspeeds. LEGACY COMPONENT DESC: Overcurrent Devices Circuitry
Due 28 February 2002
Resolved 14 February 2002
Accommodation/Occupational Safety › Messroom
Issued 29 January 2002 Resolved
Secure galley freezer to deck or bulkhead. LEGACY COMPONENT DESC: Freezer
Condition: Improper Installation
Due 28 February 2002
Resolved 14 February 2002
Construction/Loadline › Structures
Issued 29 January 2002 Resolved
Adjust/tighten dogs on watertight door in way of passageway between crew quarters & passenger area. Ensure watertight seal. LEGACY COMPONENT DESC: Door
Condition: Improper/Lack of Maintenance
Due 28 February 2002
Resolved 14 February 2002
Engineering › Compressed Air System (start air)
Issued 29 January 2002 Resolved
Install appropriate relief valve on starboard air compressor and replace relief valve on starboard air receiver with valve with manufacturer's data plate. LEGACY COMPONENT DESC: Air receiver and compressor
Due 28 February 2002
Resolved 14 February 2002
Fire Fighting › Miscellaneous Items
Issued 29 January 2002 Resolved
Eliminate excessive leakage from aft port main deck fire hydrant and replace leaking fire hose. LEGACY COMPONENT DESC: Fire hydrant and hose
Due 28 February 2002
Resolved 14 February 2002
Engineering › Fuel Oil Service System
Issued 29 January 2002 Resolved
Permanently attach remote fuel cut-off reach rod to fuel tank valve hand wheel. LEGACY COMPONENT DESC: Valve
Condition: Improper Installation
Due 28 February 2002
Resolved 14 February 2002
Electrical › Electrical Distribution System (service)
Issued 29 January 2002 Resolved
Properly dead end disconnected wiring in way of A/C Room. LEGACY COMPONENT DESC: Wiring
Condition: Improper/Lack of Maintenance
Due 28 February 2002
Resolved 14 February 2002
Documentation › Logs/Records
Issued 29 January 2002 Resolved
Conduct fire and man overboard drills. Ensure results logged in accordance with 46 CFR 185.520 & 185.524. LEGACY COMPONENT DESC: Fire and man overboard drills
Action required: 705 - Other - as specified
Due 28 February 2002
Resolved 14 February 2002
Engineering
Issued 13 June 2001 Resolved
Vessel to proceed directly to Port Bolivar Marine drydock in Bolivar TX with no cargo or passengers. Proceed to drydock for permanent repair of damage to starboard propeller that occurred during grounding on 13JUN01.
Condition: Unknown
Due 13 June 2001
Resolved 13 June 2001
Construction/Loadline
Issued 26 January 2001 Resolved
Repair/prove proper operation of visual indicators on Engineroom and Saloonbilge alarms.
Condition: Unknown
Due 26 February 2001
Resolved 21 February 2001
Electrical
Issued 26 January 2001 Resolved
Ensure electircal wire has metal supports every 24 inches in engineroom.
Condition: Unknown
Due 26 February 2001
Resolved 21 February 2001
Lifesaving
Issued 26 January 2001 Resolved
Provide U/V resistant line for life rings and lifefloats.
Condition: Unknown
Due 26 February 2001
Resolved 21 February 2001
Accommodation/Occupational Safety
Issued 26 January 2001 Resolved
Provide covers to rack lights in all cabins._x001C_ _x001C_ _x001C_ _x001C_
Condition: Unknown
Due 26 February 2001
Resolved 21 February 2001
Fire Fighting
Issued 26 January 2001 Resolved
Repair leaking fire pump seal.
Condition: Unknown
Due 26 February 2001
Resolved 21 February 2001
Lifesaving
Issued 26 January 2001 Resolved
Provide oar for lifefloat.
Condition: Unknown
Due 26 February 2001
Resolved 21 February 2001
Navigation
Issued 26 January 2001 Resolved
Update navigational charts.
Condition: Unknown
Due 26 February 2001
Resolved 21 February 2001
Unknown
Issued 18 October 2000 Resolved
Crop and renew port rudder room vent.
Condition: Unknown
Due 18 October 2000
Resolved 18 October 2000
Construction/Loadline
Issued 25 April 2000 Resolved
Reweld fractured welds in way of transom and port outboard underdeck longitudinal frame connection in lazerette.
Condition: Unknown
Due 25 April 2000
Resolved 25 April 2000
Construction/Loadline
Issued 25 April 2000 Resolved
Weld up unused pipe passage through forepeak collision bulkhead.
Condition: Unknown
Due 25 April 2000
Resolved 25 April 2000
Construction/Loadline
Issued 25 April 2000 Resolved
Align and demonstrate satisfactory seal of forward engine room watertight door.
Condition: Unknown
Due 25 April 2000
Resolved 25 April 2000
Engineering
Issued 25 April 2000 Resolved
Repair and eliminate leak from portside main engine keel cooler line.
Condition: Unknown
Due 25 April 2000
Resolved 25 April 2000
Lifesaving
Issued 24 March 2000 Resolved
REPLACE 2 REJECTED LIFE JACKETS PRIOR TO CARRYING MORE THAN 37 TOTAL PERSONS.
Condition: Unknown
Due 27 March 2000
Resolved 20 April 2000
Accommodation/Occupational Safety
Issued 24 March 2000 Resolved
Install quick acting device on Class I watertight door located aft of lowerpassenger lounge at next drydock.
Condition: Unknown
Due 28 April 2000
Resolved 14 February 2002
Electrical
Issued 24 March 2000 Resolved
ENCLOSE WIRE NUTS ON SEWAGE PUMP IN APROVED ELECTRICAL BOX OR REPLACE WITH APPROVED CONNECTORS BY 24APR00
Condition: Unknown
Due 27 April 2000
Resolved 20 April 2000
Lifesaving
Issued 24 March 2000 Resolved
REPLACE RING BUOY LOCATED ON AFT HOUSE BULKHEAD ON THE CARGO DECK PRIOR TO CARRYING PASSENGERS.
Condition: Unknown
Due 27 March 2000
Resolved 20 April 2000
Accommodation/Occupational Safety
Issued 24 March 2000 Resolved
LABEL EMERGENCY EXIT FROM CREW QUARTERS LOCATED ON DECK OF GALLEY BY 24APR00.
Condition: Unknown
Due 27 March 2000
Resolved 20 April 2000
Electrical
Issued 26 March 1999 Resolved
REPLACE OR REPAIR NON-WORKING BATTERY CHARGER UNIT IN ENGINE COMPARTMENT.
Condition: Unknown
Due 26 March 1999
Resolved 26 March 1999
Deck/Cargo
Issued 26 March 1999 Resolved
PROVIDE ON BOARD VALID FCC STATION & OPERATOR LICENSES.
Condition: Unknown
Due 26 March 1999
Resolved 26 March 1999
Engineering
Issued 26 March 1999 Resolved
ELIMINATE ECESSIVE LEAKAGE FROM PORT & STARBOARD SHAFT LOGS.
Condition: Unknown
Due 26 March 1999
Resolved 26 March 1999
Accommodation/Occupational Safety
Issued 26 March 1999 Resolved
REPAIR LEAKING PIPING FROM TIOLET TO MSD IN WAY OF ENGINE COMPARTMENT.
Condition: Unknown
Due 26 March 1999
Resolved 26 March 1999
Engineering
Issued 26 March 1999 Resolved
PROPERLY MARK FUEL REMOTE SHUT OFF VALVES IAW 46 CFR 185.610.
Condition: Unknown
Due 26 March 1999
Resolved 26 March 1999
Navigation
Issued 26 March 1999 Resolved
SECURE HYDRAULIC LEAK FROM INBOARD HYDRAULIC STEERING SYSTEM HOSE.
Condition: Unknown
Due 26 March 1999
Resolved 6 April 1999
Fire Fighting
Issued 26 March 1999 Resolved
REMOVE EXCESSIVE PAINT FROM ENGINE ROOM VENT DAMPER & HINGES - ENSURE PROPER FIT.
Condition: Unknown
Due 26 March 1999
Resolved 26 March 1999
Unknown
Issued 26 March 1999 Resolved
REMOVE EXCESSIVE OIL WATER MIXTURE FROM ENGINE COMPARTMENT BILGES.
Condition: Unknown
Due 26 March 1999
Resolved 26 March 1999
Engineering
Issued 26 March 1999 Resolved
ELIMINATE VIBRATION IN PORT SHAFT.
Condition: Unknown
Due 26 March 1999
Resolved 26 March 1999
Lifesaving
Issued 26 March 1999 Resolved
MARK EXPIRATION DATE ON EPIRB HYDROSTATIC RELEASE UNIT.
Condition: Unknown
Due 26 March 1999
Resolved 26 March 1999
Construction/Loadline
Issued 26 March 1999 Resolved
REPAIR 4 CRACKED WELDS IN STEERING COMPARTMENT, ON STARBOARD SIDE IN WAY OFSTERN / DECK CONNECTION.
Condition: Unknown
Due 26 March 1999
Resolved 26 March 1999
Navigation
Issued 26 March 1999 Resolved
SECURE LEAKAGE FROM STARBOARD SIDE RUDDER POST.
Condition: Unknown
Due 26 March 1999
Resolved 26 March 1999
Documentation
Issued 18 August 1995 Resolved
OPERATE VESSEL PER CURRENT STABILITY LETTER UNTIL ISSUED NEW STABILITY _x001C_ LETTER IS ISSUED BY THE MARINE SAFETY CENTER.
Condition: Unknown
Due 18 August 1995
Resolved 18 August 1995
Documentation
Issued 9 June 1994 Resolved
PRIOR TO CARRYING PASSENGERS FOR HIRE, A U. S. LOADLINE IS TO BE OBTAINED FOR THIS VESSEL AND THE COAST GUARD NOTIFIED.
Condition: Unknown
Due 9 June 1994
Resolved 9 June 1994
Engineering
Issued 28 April 1994 Resolved
REPAIR/REPLACE PORT SIDE AIR RECIEVER SAFTY RELEIF VALVE.
Condition: Unknown
Due 28 April 1994
Resolved 28 April 1994
Construction/Loadline
Issued 28 April 1994 Resolved
REPAIR CRACKED WELDS IN STEERING GEAR ROOM ALONG PORTSIDE OVERHEAD.
Condition: Unknown
Due 28 April 1994
Resolved 28 April 1994
Engineering
Issued 28 April 1994 Resolved
REPLACE/DOUBLE CLAMP OVERBOARD DISCHARGE HOSES IN STEERING GEAR ROOM.
Condition: Unknown
Due 28 April 1994
Resolved 28 April 1994
Engineering
Issued 28 April 1994 Resolved
REMOVE EXCESS OIL FROM ENGINE ROOM / AUXILIARY SPACES.
Condition: Unknown
Due 28 April 1994
Resolved 28 April 1994
Navigation
Issued 28 April 1994 Resolved
PROVIDE STEERING STOPS FOR RUDDERS.
Condition: Unknown
Due 28 April 1994
Resolved 28 April 1994
Engineering
Issued 28 April 1994 Resolved
REMOVE TWO DEAD END WIRES FROM ENGINE ROOM IN OVERHEAD BETWEEN MAINS.
Condition: Unknown
Due 28 April 1994
Resolved 28 April 1994
Construction/Loadline
Issued 28 April 1994 Resolved
REPLACE OVERBOARD DISCHARGE PIPING THROUGH FOREPEAK.
Condition: Unknown
Due 28 April 1994
Resolved 28 April 1994
Navigation
Issued 28 April 1994 Resolved
REPAIR/REPLACE/REMOVE TOP RADAR IN BRIDGE.
Condition: Unknown
Due 28 April 1994
Resolved 28 April 1994
Engineering
Issued 28 April 1994 Resolved
DOUBLE CLAMP ALL OVERBOARD DISCHARGES IN GENERATOR ROOM.
Condition: Unknown
Due 28 April 1994
Resolved 28 April 1994
Electrical
Issued 9 May 1991 Resolved
REMOVE ALL UNUSED ELECTRICAL WIRING AND CONNECTION ON BOTH MAIN PROPULSION ENGINES._x001C_ _x001C_ _x001C_
Condition: Unknown
Due 9 May 1991
Resolved 9 May 1991
Electrical
Issued 9 May 1991 Resolved
REPLACE ALL TIE WRAPS WITH METAL WRAPS ON WIRING WHERE IN CREW/PERSONNEL ACCESS IN ENGINE ROOM._x001C_ _x001C_ _x001C_
Condition: Unknown
Due 9 May 1991
Resolved 9 May 1991
Construction/Loadline
Issued 3 May 1990 Resolved
GOUGE AND WELD THREE FRACTURED WELDS IDENTIFIED BY COAST GUARD INSPECTOR INTHE PORT STERN CORNER AREA. REPAIRS TO BE COMPLETED TO THE SATISFACTION OFTHE ATTENDING COAST GUARD INSPECTOR.
Condition: Unknown
Due 3 May 1990
Resolved 3 May 1990
Construction/Loadline
Issued 3 May 1990 Resolved
GOUGE AND WELD THREE FRACTURES IDENTIFIED BY COAST GUARD INSPECTOR IN RUB RAIL.
Condition: Unknown
Due 3 May 1990
Resolved 3 May 1990
Construction/Loadline
Issued 3 May 1990 Resolved
GOUGE AND WELD TWO FRACTURED WELDS ON STRENGTH MEMBERS IDENTIFIED BY COAST GUARD INSPECTOR BELOW CREW ACCOMMODATIONS SPACE.
Condition: Unknown
Due 3 May 1990
Resolved 3 May 1990
Construction/Loadline
Issued 3 May 1990 Resolved
PROVIDE ON BOARD 190 LB. ANCHOR AS A MINIMUM. DEMONSTRATE RAISING AND LOWERING OF ANCHOR VIA ANCHOR WINDLASS TO THE SATISFACTION OF THE ATTENDINGCOAST GUARD INSPECTOR.
Condition: Unknown
Due 3 May 1990
Resolved 3 May 1990
Accommodation/Occupational Safety
Issued 15 June 1989 Resolved
REPAIR SEWAGE SYSTEM PIPING.
Condition: Unknown
Due 15 June 1989
Resolved 15 June 1989
Engineering
Issued 15 June 1989 Resolved
REPAIR VENT DUCT CLOSURE FOR PORT AFT E/R INTAKE DUCT.
Condition: Unknown
Due 15 June 1989
Resolved 15 June 1989
Engineering
Issued 15 June 1989 Resolved
RE-MOUNT ENGINE ALARM CONTROL BOXES AFT OF ENGINES IN E/R.
Condition: Unknown
Due 15 June 1989
Resolved 15 June 1989
Navigation
Issued 15 June 1989 Resolved
REPAIR/REPLACE HANGARS FOR GENERATOR EXHAUST PIPING IN STEERING GEAR ROOM.
Condition: Unknown
Due 15 June 1989
Resolved 15 June 1989
Electrical
Issued 16 June 1988 Resolved
REPAIR ENGINE ROOM ELECTRICAL PANEL (PORT SIDE).
Condition: Unknown
Due 16 June 1988
Resolved 16 June 1988
Accommodation/Occupational Safety
Issued 16 June 1988 Resolved
PERMANTLY INSTALL MSD PIPING TO VACCUUM PUMP LOCATED IN FWD SECTION OF MACHINERY SPACE
Condition: Unknown
Due 16 June 1988
Resolved 16 June 1988
Electrical
Issued 16 June 1988 Resolved
REINSTALL LOCK-OUT BAR ON SWITCHBOARD
Condition: Unknown
Due 16 June 1988
Resolved 16 June 1988
Engineering
Issued 16 June 1988 Resolved
PERMANENTLY INSTALL PORT ENGINE ALARM BOX (AFT END PORT ENGINE).
Condition: Unknown
Due 16 June 1988
Resolved 16 June 1988
Electrical
Issued 18 June 1987 Resolved
PROVIDE COVER FOR PORT GENERATOR STARTING BATTERY.
Condition: Unknown
Due 18 June 1987
Resolved 18 June 1987
Electrical
Issued 18 June 1987 Resolved
REPAIR OR REPLACE TACHOMETER FOR STARBOARD GENERATOR.
Condition: Unknown
Due 18 June 1987
Resolved 18 June 1987
Construction/Loadline
Issued 18 June 1987 Resolved
REPAIR HOLES IN ENGINEROOM OVERHEAD (2 HOLES OVER CABLE RUN).
Condition: Unknown
Due 18 June 1987
Resolved 18 June 1987

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.