A report is not offered for this hull: Its record holds only 2 of the seven kinds of material a report is built from: inspections, deficiencies, operational controls, tow-unit appearances, casualty records, dimensions and documentation. That is a statement about the record, not about the vessel. Reports.
Inspection history · 26
2 February 2023
Administrative Inspection
Administrative · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 7631341
27 October 2021
Deficiency Check · Internal Structural Exam · Drydock Exam · COI Inspection
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 7333611
1 December 2020
Administrative Inspection
Administrative · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 7104656
5 March 2019
Simplified Stability Test
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 6638843
9 January 2019
COI Inspection · Administrative Inspection · Deficiency Check
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 6618350
7 May 2018
Annual Inspection · Deficiency Check
Physical examination · Marine Safety Unit Portland OR · USCG Northwest District (CGD-NW) · Activity 6402486
23 March 2017
Annual Inspection
Physical examination · Marine Safety Unit Portland OR · USCG Northwest District (CGD-NW) · Activity 6105438
7 March 2016
COI Inspection · Hull Examination
Physical examination · Marine Safety Unit Portland OR · USCG Northwest District (CGD-NW) · Activity 5825437
18 March 2010
Annual Inspection
Physical examination · Sector Portland · USCG Northwest District (CGD-NW) · Activity 3682491
21 April 2009
Deficiency Check
Physical examination · Sector Portland · USCG Northwest District (CGD-NW) · Activity 3457751
19 March 2009
Annual Inspection
Physical examination · Sector Portland · USCG Northwest District (CGD-NW) · Activity 3428869
13 March 2008
Deficiency Check · COI Inspection
Physical examination · Sector Portland · USCG Northwest District (CGD-NW) · Activity 3171084
28 March 2007
Deficiency Check · Annual Inspection
Physical examination · Sector Portland · USCG Northwest District (CGD-NW) · Activity 2883411
4 April 2006
Deficiency Check
Physical examination · Sector Portland · USCG Northwest District (CGD-NW) · Activity 2692459
1 February 2006
Hull Examination · COI Inspection
Physical examination · Sector Portland · USCG Northwest District (CGD-NW) · Activity 2572242
2 April 2005
Annual Inspection · Deficiency Check
Physical examination · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 2295352
29 March 2004
Deficiency Check · Annual Inspection
Physical examination · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 2022909
29 March 2003
Deficiency Check · Annual Inspection
Physical examination · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 1757040
16 May 2002
Deficiency Check
Physical examination · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 1617544
29 March 2002
Annual Inspection
Physical examination · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 1495001
18 March 2001
COI Inspection
Physical examination · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 1445773
1 March 2000
Re-Inspection
Physical examination · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 1420267
13 May 1999
Deficiency Check
Physical examination · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 797379
13 April 1999
Re-Inspection
Physical examination · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 789176
29 September 1998
Deficiency Check
Physical examination · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 1375516
30 July 1998
Deficiency Check · Initial Construction-Excluding Oversight · Initial Certification · Hull Examination
Physical examination · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 1461900
01 - Certificates & Documentation › 011 - Ships Certificates › Certificate of Inspection (COI)
Issued 2 February 2023
Resolved
Your vessel must undergo an annual inspection within the 3 months before or after each anniversary date. Vessel is past due for annual inspection. Complete a satisfactory annual inspection with USCG marine inspectors.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 3 February 2023
01 - Certificates & Documentation › 011 - Ships Certificates › Certificate of Inspection (COI)
Issued 1 December 2020
Resolved
An annual inspection must be completed within the 3 months before or after the anniversary date of 27 MARCH.
To maintain a valid Certificate of Inspection, an annual inspection must be completed. Vessel is not authorized to carry passengers until the required inspection is completed. Contact Sector San Diego Eastern AOR Inspections Coordinator to schedule inspection. Submit CG-3752 to [email withheld] with request for renewal COI.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 27 October 2021
Resolution: COI inspection completed.
Communications › Audible Communications › Horn/Whistle
Issued 7 May 2018
Resolved
Repair and/or replace horn; prove proper operation.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 7 June 2018
Resolved 16 May 2018
Resolution: New 12V electrical horn was installed and tested by the owner.
Fire Fighting › Fire Bucket › Availability
Issued 7 May 2018
Resolved
Provide one (1) additional 2 1/2 gallon fire bucket with lanyard; ensure bucket is properly labeled.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 7 June 2018
Resolved 16 May 2018
Resolution: Vessel owner purchased new 2 1/2 gallon fire bucket. Bucket was properly labeled, and had a lanyard tied to the handle.
Accommodation/Occupational Safety › Medical/First Aid › Medicine Chest
Issued 7 May 2018
Resolved
Replace expired items in first aid kit.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 7 June 2018
Resolved 16 May 2018
Resolution: Vessel owner replaced expired items in the first aid kit carried aboard the vessel.
Navigation › Collision/Grounding Avoidance › Navigation Lights
Issued 18 March 2010
Resolved
Repair extinguished port navigational light.
Condition: Damaged By Earlier Event
Due 18 April 2010
Resolved 17 May 2010
Resolution: Received fax from owner stating that the port nav light fixture was replaced.
Communications › Audible Communications › Horn/Whistle
Issued 18 March 2010
Resolved
Repair inoperable horn.
Condition: Damaged By Earlier Event
Due 18 April 2010
Resolved 17 May 2010
Resolution: Received fax from owner stating that the electric horn had been replaced.
Lifesaving › Lifebuoys › Buoyant Lifeline
Issued 18 March 2010
Resolved
Renew lifeline on ring buoy.
Condition: Improper/Lack of Maintenance
Due 18 April 2010
Resolved 17 May 2010
Resolution: Received fax from owner stating that the lifeline had been replaced.
Fire Fighting › Ventilation Systems › Ducts
Issued 18 March 2010
Resolved
Install metalic ventilation hose in place of plastic ventilation hose near port engine.
Condition: Improper/Lack of Maintenance
Due 18 April 2010
Resolved 17 May 2010
Resolution: Received fax from owner stating that the ER vent hose had been replaced.
Operations/Management › Bilge/Bilge System Management › Control of Oil Mixtures
Issued 18 March 2010
Resolved
Remove excess oil in engine room bilge.
Condition: Improper/Lack of Maintenance
Due 18 April 2010
Resolved 17 May 2010
Resolution: Received fax from owner stating that all of the oil has been removed from the bilges.
Fire Fighting › Ventilation Systems › Fans
Issued 18 March 2010
Resolved
Repair inoperable mechanical ventilation exhaust blower on starboard side of engine room.
Condition: Damaged By Earlier Event
Due 18 April 2010
Resolved 17 May 2010
Resolution: Received fax from owner stating that the blower switch wiring had been renewed.
Operations/Management › Bilge/Bilge System Management › Control of Oil Mixtures
Issued 19 March 2009
Resolved
Remove oil from bilge and stop excessive oil leaks.
Action required: 701 - Prior to carriage of passengers/cargo
Due 19 April 2009
Resolved 21 April 2009
Resolution: Cleaned bilges, provided tech rep report showing replacement of valve cover gaskets.
Fire Fighting › Portable Dry Chemical Fire Extinguisher › Service
Issued 19 March 2009
Resolved
Have all fire extinguishing equipment serviced and provide proof of service to CG Inspector.
Action required: 701 - Prior to carriage of passengers/cargo
Due 19 April 2009
Resolved 21 April 2009
Resolution: Oxarc serviced all extinguishers.
Communications › Audible Communications › Horn/Whistle
Issued 19 March 2009
Resolved
Make horn operable.
Action required: 701 - Prior to carriage of passengers/cargo
Due 19 April 2009
Resolved 21 April 2009
Resolution: Owner provided proof of new horn purchase.
Accommodation/Occupational Safety › Medical/First Aid › Medicine Chest
Issued 19 March 2009
Resolved
Provide approved first aid kit. Send proof of purchase to CG Inspector.
Action required: 701 - Prior to carriage of passengers/cargo
Due 19 April 2009
Resolved 21 April 2009
Resolution: Received proof of purchase from owner.
Fire Fighting › Portable Dry Chemical Fire Extinguisher › Service
Issued 13 March 2008
Resolved
Have all fire extinguishers serviced ICAW NFPA 10.
Action required: 701 - Prior to carriage of passengers/cargo
Due 13 April 2008
Resolved 3 April 2008
Resolution: All fire extinguishers have been serviced.
Fire Fighting › Fixed Halon Fire Extinguishing System › Tanks
Issued 13 March 2008
Resolved
Have fixed fire extinguishing system serviced and provide proof to attending CG Marine inspector.
Action required: 701 - Prior to carriage of passengers/cargo
Due 13 April 2008
Resolved 3 April 2008
Resolution: Fixed fire system has been serviced.
Communications › Audible Communications › Horn/Whistle
Issued 13 March 2008
Resolved
Make horn operable.
Action required: 701 - Prior to carriage of passengers/cargo
Due 13 April 2008
Resolved 3 April 2008
Resolution: New horn installed.
Operations/Management › Bilge/Bilge System Management › Control of Oil Mixtures
Issued 13 March 2008
Resolved
Remove excessive oil and water from bilge.
Action required: 705 - Other - as specified
Due 13 April 2008
Resolved 3 April 2008
Resolution: Bilges have been cleaned. Source of oil was from a previous oil change.
Electrical › Electric Supply System (service) › Battery Installation
Issued 28 March 2007
Resolved
Provide covers for batteries.
Due 30 April 2007
Resolved 28 March 2007
Resolution: corrected
Navigation › Collision/Grounding Avoidance › Navigation Lights
Issued 28 March 2007
Resolved
Make port and stern navigation lights operable.
Due 30 April 2007
Resolved 28 March 2007
Resolution: corrected
Accommodation/Occupational Safety › Medical/First Aid › Medicine Chest
Issued 28 March 2007
Resolved
Replace expired items in first aid kit.
Due 30 April 2007
Resolved 28 March 2007
Resolution: completed
Operations/Management › Drug and Alcohol Testing › Proof of Enrollment
Issued 28 March 2007
Resolved
Provide drug testing proof o9f enrollment for all employees.
Due 30 April 2007
Resolved 26 April 2007
Resolution: Corrected
Construction/Loadline › Penetrations › Gasket
Issued 28 March 2007
Resolved
Make watertight mores cables at stern.
Due 30 April 2007
Resolved 26 April 2007
Resolution: Corrected
Fire Fighting › Fixed Fire Detection System › Arrangement
Issued 28 March 2007
Resolved
Prove operation of fire system discharge alarm.
Due 30 April 2007
Resolved 28 March 2007
Resolution: Corrected
Lifesaving › Lifejacket/PFD (General) › Storage
Issued 28 March 2007
Resolved
Re-stencil location of lifejacket.
Due 30 April 2007
Resolved 26 April 2007
Resolution: Corrected
Operations/Management › Bilge/Bilge System Management › Control of Excess Water
Issued 1 February 2006
Resolved
Renew/repair high water level alarm. 46 CFR 182.530
Due 1 March 2006
Resolved 4 April 2006
Resolution: Received letter from Master stating high water level alarm was replaced.
Documentation › Certificates/Documents › Certificate of Number (state)
Issued 1 February 2006
Resolved
Prove proper state registration of vessel. 46 CFR 67.7.67(c)
Due 1 March 2006
Resolved 4 April 2006
Resolution: Received copy of new state registration from owner.
Lifesaving › Lifebuoys
Issued 29 March 2003
Resolved
Provide retro-reflective tape for ring buoy and repair the floating water light. 46 CFR 180.70 LEGACY COMPONENT DESC: Self-igniting Lights
Condition: Improper/Lack of Maintenance
Due 29 April 2003
Resolved 20 April 2003
Accommodation/Occupational Safety › Medical/First Aid › Medicine Chest
Issued 29 March 2003
Resolved
Update expired first aid kit items. 46 CFR 184.710
Condition: Improper/Lack of Maintenance
Due 29 April 2003
Resolved 20 April 2003
Lifesaving › Hand Flares
Issued 29 March 2002
Resolved
Replace all expired flares on vessel IAW 46 CFR 180.70 To be completed prior to the carriage of passengers. LEGACY COMPONENT DESC: Condition
Due 29 April 2002
Resolved 16 May 2002
Engineering › Gasoline Engine (propulsion)
Issued 29 March 2002
Resolved
Renew all fuel hoses greater than 30" with hose approved for fittings IAW 46 CFR 180.720. SAE J-1527 (CG A1 hose) made for fittings which meet SAE J-1942 hose, are approved. To be completed prior to the carriage of passengers. LEGACY COMPONENT DESC: Fuel Hoses
Condition: Placed in Improper Service
Due 29 April 2002
Resolved 16 May 2002
Fire Fighting › Fixed Fire Detection System
Issued 29 March 2002
Resolved
Repair/renew Fireboy audible/visual alarm system for the engine room fixed fire fighting system. System is to shutdown engines and ventilation upon discharge of the halon agent, or replace current 194 F heat detector with a 160 F model. 46 CFR 181.720. LEGACY COMPONENT DESC: Heat Detectors
Condition: Placed in Improper Service
Due 29 April 2002
Resolved 16 May 2002
Accommodation/Occupational Safety › Medical/First Aid
Issued 29 March 2002
Resolved
Update expired first aid kit items. 46 CFR 184.710
Condition: Improper/Lack of Maintenance
Due 29 April 2002
Resolved 16 May 2002
Electrical
Issued 18 March 2001
Resolved
PROVIDE TWO PORTABLE FLASH LIGHTS.
Condition: Unknown
Due 9 April 2001
Resolved 9 April 2001
Navigation
Issued 18 March 2001
Resolved
REPAIR OR RENEW VESSEL HORN OR PROVIDE HORN.
Condition: Unknown
Due 9 April 2001
Resolved 9 April 2001
Fire Fighting
Issued 18 March 2001
Resolved
LOWER FUME DETECTOR TO APPROX, 6" ABOVE BILGE BOTTOM.
Condition: Unknown
Due 9 April 2001
Resolved 9 April 2001
Lifesaving
Issued 13 April 1999
Resolved
Mark lifejacket stowage locations with quantity and type (Adult/Child).
Condition: Unknown
Due 13 April 1999
Resolved 13 April 1999
Fire Fighting
Issued 13 April 1999
Resolved
Provide proof of annual servicing of fixed fire system and portable extinguisher.
Condition: Unknown
Due 13 April 1999
Resolved 13 April 1999
Engineering
Issued 13 April 1999
Resolved
Mark fuel shutoff at handle with on/off.
Condition: Unknown
Due 13 April 1999
Resolved 13 April 1999
Construction/Loadline
Issued 30 July 1998
Resolved
PROVIDE 5 GPM HAND-POWERED BILGE PUMP.
Condition: Unknown
Due 26 August 1998
Resolved 26 August 1998
Documentation
Issued 30 July 1998
Resolved
PROVIDE EVIDENCE OF VESSEL'S STATE REGISTRATION.
Condition: Unknown
Due 26 August 1998
Resolved 26 August 1998
Lifesaving
Issued 30 July 1998
Resolved
PROVIDE FIRST AID KIT PER 46 CFR 184.710.
Condition: Unknown
Due 26 August 1998
Resolved 26 August 1998
Lifesaving
Issued 30 July 1998
Resolved
POST COPY OF LIFE JACKET DONNING PLACARD ON BOARD.
Condition: Unknown
Due 30 July 1998
Resolved 30 July 1998
Engineering
Issued 30 July 1998
Resolved
INSTALL ONE ADDITIONAL EXHAUST BLOWER TO UNPOWERED ENGINE COMPARTMENT EXH VENT.
Condition: Unknown
Due 26 August 1998
Resolved 26 August 1998
Fire Fighting
Issued 30 July 1998
Resolved
PROVIDE ONE BII (10 LB) DRY CHEMICAL PORTABLE FIRE EXTINGUISHER.
Condition: Unknown
Due 26 August 1998
Resolved 26 August 1998
Engineering
Issued 30 July 1998
Resolved
PROVIDE 30 X 30 MESH FLAME SCREENS FOR BOTH FUEL FILTER DRIP PANS.
Condition: Unknown
Due 26 August 1998
Resolved 26 August 1998
Accommodation/Occupational Safety
Issued 30 July 1998
Resolved
PROVIDE SAFETY CHAIN GATES/BARRIERS ON FWD END OF AFT DECK RAILING.
Condition: Unknown
Due 26 August 1998
Resolved 26 August 1998
Lifesaving
Issued 30 July 1998
Resolved
PROVIDE DISTRESS SIGNALS PER 46 CFR 180.68 (3 SMOKES/3 HAND HELD RED FLARES) WITH CASE.
Condition: Unknown
Due 26 August 1998
Resolved 26 August 1998
Lifesaving
Issued 30 July 1998
Resolved
PROVIDE THE FOLLOWING PLACARDS ON BOARD: A) OIL DISCHARGE PLACARD; B) GARBAGE PLACARD; C) EMERGENCY CHECK-OFF; D) LIFE JACKET DONNING PLACARD.
Condition: Unknown
Due 26 August 1998
Resolved 26 August 1998
Engineering
Issued 30 July 1998
Resolved
PROVIDE VENT CLOSURE DEVICES FOR EACH ENGINE COMPT VENT OPENING.
Condition: Unknown
Due 26 August 1998
Resolved 26 August 1998