Records from 1983 to 1990. Most recent: inspection, 29 January 1990.
Documentation record
Registered dimensions (L × B × D)374.0 ft × 65.2 ft × 26.8 ft
Registered tonnagegross 5,972 / net 3,894
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
BuilderLEVINGSTON SHIPBUILDING · ORANGE, TX, UNITED STATES · built 1974
Hull materialSteel
PropulsionDiesel Electric
Hull shapeNot recorded
Hull configurationNot recorded
Hailing portHOUSTON, TX
Trade endorsementsCoastwise, unrestricted, Registry
DocumentationNo Operation - PM · issued 7 September 1982
Service, as the file records itMobile Offshore Drilling Unit
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it5972 - Regulatory (Subpart C or D), Gross Ton
3894 - Regulatory (Subpart C or D), Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 September 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.
A report is not offered for this hull: Its record holds only 2 of the seven kinds of material a report is built from: inspections, deficiencies, operational controls, tow-unit appearances, casualty records, dimensions and documentation. That is a statement about the record, not about the vessel. Reports.
Inspection history · 16
29 January 1990
Administrative
Administrative · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1223818
27 April 1989
Re-Inspection
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1040231
6 May 1988
Type not recorded
No type recorded · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1039355
14 April 1988
Administrative
Administrative · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1340990
19 February 1988
Drydock Extension
Administrative · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1027282
19 February 1988
COI Inspection
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1029360
19 February 1988
Drydock Extension
Administrative · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1029935
29 September 1986
Type not recorded
No type recorded · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1005279
29 September 1986
Type not recorded
No type recorded · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1313572
23 February 1986
Type not recorded
No type recorded · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 994273
16 October 1985
COI Inspection
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1299912
19 November 1984
Type not recorded
No type recorded · MSO Mobile · USCG Heartland District (CGD-H) · Activity 976710
24 September 1984
Type not recorded
No type recorded · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1285188
7 February 1984
Type not recorded
No type recorded · MSO Mobile · USCG Heartland District (CGD-H) · Activity 971712
17 November 1983
Type not recorded
No type recorded · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 970759
17 October 1983
Type not recorded
No type recorded · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1275897
Lifesaving
Issued 19 February 1988
Resolved
END FOR END BOTH SETS OF LIFEBOAT FALLS.
Condition: Unknown
Due 31 July 1988
Resolved 18 May 2002
Resolution: MISLE Maintenance - Resolved all open deficiencies issued prior to 6/1/1997 where activity was closed and deficiency due date was past
Unknown
Issued 19 February 1988
Resolved
INSTALL COAST GUARD APPROVED OWS WITH MONITOR AND CONTROL SYSTEM AS RE- QUIRED BY MARPOL 73/78. UNTIL THIS ITEM IS COMPLETED THERE SHALL BE NO DISCHARGE OF E/R BILGES TO SEA DIRECTLY OR INDIRECTLY EXCEPT FOR SAFETY OF VESSEL.
Condition: Unknown
Due 31 July 1988
Resolved 18 May 2002
Resolution: MISLE Maintenance - Resolved all open deficiencies issued prior to 6/1/1997 where activity was closed and deficiency due date was past
Unknown
Issued 19 February 1988
Resolved
POST "DO NOT USE" ON AND OTHERWISE RENDER INOPERABLE THE NUMBER 7 BULK POD GEL TANK UNTIL REPAIRS AND/OR TESTING ACCEPTABLE TO [name withheld] CARRIED OUT TO THE SATISFACTION OF A COAST GUARD MARINE INSPECTOR.
Condition: Unknown
Due 31 July 1988
Resolved 18 May 2002
Resolution: MISLE Maintenance - Resolved all open deficiencies issued prior to 6/1/1997 where activity was closed and deficiency due date was past
Unknown
Issued 16 October 1985
Resolved
ON DRAWWORKS AIR RECEIVER, REMOVE FOR INTERNAL CLEANING OF RUST AND RE-HYDRO TEST. SUBMIT RESULTS TO MIONY.
Condition: Unknown
Due 16 October 1985
Resolved 16 October 1985
Unknown
Issued 16 October 1985
Resolved
PROVIDE COAST GUARD APPROVAL NUMBER FOR MARINE SANITATION DEVICE.
Condition: Unknown
Due 16 October 1985
Resolved 16 October 1985
Documentation
Issued 16 October 1985
Resolved
MAKE CHANGE TO VESSELS DOCUMENTATION CERTIFICATE WITH CORRECT OWNERS NAME AND ADDRESS.
Condition: Unknown
Due 16 October 1985
Resolved 16 October 1985
Lifesaving
Issued 16 October 1985
Resolved
RESERVICE ALL FOUR LIFE RAFTS PRIOR TO 01JUN86 AT A COAST GUARD APPROVED SERVICING FACILITY.
Condition: Unknown
Due 16 October 1985
Resolved 16 October 1985
Unknown
Issued 16 October 1985
Resolved
PROVIDE A PERMANENT INSTALLATION FOR DISCHARGE OF DIRTY BILGE SLOPS STBD SIDE OF VESSEL. SUBMIT PLANS TO USCG FOR APPROVAL OF PIPING PRIOR TO INSTALLATION.
Condition: Unknown
Due 16 October 1985
Resolved 16 October 1985
Deck/Cargo
Issued 24 September 1984
Resolved
ENSURE INDUSTRIAL TRUCKS ON BOARD COMPLY WITH 46 CFR 108.613 AND 109.537.
Condition: Unknown
Due 24 September 1984
Resolved 24 September 1984
Documentation
Issued 24 September 1984
Resolved
PROVIDE FIRE CONTROL PLAN AND HAZARDOUS LOCATIONS PLAN TO OFFICER IN CHARGEMARINE INSPECTION, 600 S. MAESTRI PLACE, NEW ORLEANS, LA 70130 FOR APPRO- VAL, 46 CFR 107.305.
Condition: Unknown
Due 24 September 1984
Resolved 24 September 1984
Unknown
Issued 24 September 1984
Resolved
THE FOLLOWING DEFICIENCIES PERTAIN TO THE M/V GLOMAR CORAL SEA, O.N. 557757THE BELOW LISTED ITEMS ARE TO BE COMPLIED WITH BY 31OCT84.
Condition: Unknown
Due 24 September 1984
Resolved 24 September 1984
Fire Fighting
Issued 24 September 1984
Resolved
PROVIDE TWO (2) UL OR FM APPROVED OXYGEN/EXPLOSIVE METERS FOR FIREMAN'S OUTFITS, 46 CFR 108.497.
Condition: Unknown
Due 24 September 1984
Resolved 24 September 1984
Unknown
Issued 17 November 1983
Resolved
REPLACE OR MAKE PERMANENT REPAIRS TO PORT AFT CRANE (S/N19GT3-100305) PRIORTO 1FEB84 OR SUBMIT TEMPORARY REPAIRS TO ABS OR ICGB FOR ADEQUACY AT DERAT-
Condition: Unknown
Due 17 November 1983
Resolved 17 November 1983
Unknown
Issued 17 November 1983
Resolved
THE FOLLOWING ITEM PERTAINS TO THE M/V GLOMAR CORAL SEA, O.N. DN557757
Condition: Unknown
Due 17 November 1983
Resolved 17 November 1983
Unknown
Issued 17 November 1983
Resolved
(REQ. NO. 1 CONT.) ED LOADED AND CONDUCT QUADRENIAL SURVEY.
Condition: Unknown
Due 17 November 1983
Resolved 17 November 1983
Unknown
Issued 17 October 1983
Resolved
THE FOLLOWING DEFICIENCIES PERTAIN TO THE MODU GLOMAR CORAL SEA, DN557757.
Condition: Unknown
Due 17 October 1983
Resolved 17 October 1983
Lifesaving
Issued 17 October 1983
Resolved
PROVIDE ANNUAL SERVICING OF HYDROSTATIC RELEASES AND MOUNT PROPERLY ON NUMBER ONE (1), TWO (2) AND THREE (3) INFLATABLE LIFERAFTS, IN ACCORDANCE
Condition: Unknown
Due 17 October 1983
Resolved 17 October 1983
Unknown
Issued 17 October 1983
Resolved
(REQ. 1 CONTINUED) WITH 46 CFR 108.505.
Condition: Unknown
Due 17 October 1983
Resolved 17 October 1983
Navigation
Issued 17 October 1983
Resolved
PROVIDE PROPER BULBS IN ALL NAVIGATION LIGHTS, IN ACCORDANCE WITH 46 CFR 111.75-15.
Condition: Unknown
Due 17 October 1983
Resolved 17 October 1983
Documentation
Issued 17 October 1983
Resolved
PROVIDE A GULF COAST LIGHTS LIST ON BOARD VESSEL, IN ACCORDANCE WITH 46 CFR 109.5-65.
Condition: Unknown
Due 17 October 1983
Resolved 17 October 1983
Fire Fighting
Issued 17 October 1983
Resolved
PROVIDE NAPTHA FOR FLAME SAFETY LAMP IN EACH FIREMANS OUTFIT, IN ACCORDANCEWITH 46 CFR 108.497 (46 CFR 96.35).
Condition: Unknown
Due 17 October 1983
Resolved 17 October 1983
Accommodation/Occupational Safety
Issued 17 October 1983
Resolved
PROVIDE REPORT OF NON DESTRECTIVE TESTING OF PRESSURE VESSELS TO MARINE INSPECTION OFFICE NEW ORLEANS, IN ACCORDANCE WITH 46 CFR 54.
Condition: Unknown
Due 17 October 1983
Resolved 17 October 1983
Electrical
Issued 17 October 1983
Resolved
ON THE DRILL FLOOR BANK ALL ELECTRICAL CABLE RUNS AND MAKE SUITABLE FOR HAZARDOUS LOCATION, IN ACCORDANCE WITH 46 CFR 111.
Condition: Unknown
Due 17 October 1983
Resolved 17 October 1983
Electrical
Issued 17 October 1983
Resolved
ON THE DRILL FLOOR REMOVE SPLICE IN TOTCO LINE AND MAKE SUITABLE FOR HAZARDOUS LOCATION, IN ACCORDANCE WITH 46 CFR 111.80.
Condition: Unknown
Due 17 October 1983
Resolved 17 October 1983
Electrical
Issued 17 October 1983
Resolved
ON THE DRILL FLOOR MAKE JUNCTION BOX BEHIND TOTCO UNIT STROKE COUNTER SUITABLE FOR HAZARDOUS LOCATION, IN ACCORDANCE WITH 46 CFR 111.80.
Condition: Unknown
Due 17 October 1983
Resolved 17 October 1983
Electrical
Issued 17 October 1983
Resolved
IN THE LOWER DECK SHALE SHAKER PROVIDE EYS FITTINGS FOR DESANDER MOTOR AND CONTROLLER AND EYS FITTING FOR SHALE SHAKER MOTOR PORT SIDE AND PROPERLY
Condition: Unknown
Due 17 October 1983
Resolved 17 October 1983
Unknown
Issued 17 October 1983
Resolved
(REQ. 9 CONTINUED) SECURE ELECTRICAL CABLES IN THE SPACE, IN ACCORDANCE WITH 46 CFR 111.80.
Condition: Unknown
Due 17 October 1983
Resolved 17 October 1983
Electrical
Issued 17 October 1983
Resolved
ON THE MAIN DECK MAKE AUTOMATIC MUD CONTROLLERS SUITABLE FOR HAZARDOUS LOCATION, IN ACCORDANCE WITH 46 CFR 111.80.
Condition: Unknown
Due 17 October 1983
Resolved 17 October 1983
Deck/Cargo
Issued 17 October 1983
Resolved
POST CLEAR OPERATING AND LOAD LIMITATIONS FOR DAMAGED CRANE (SN19GT-100305), REPLACE OR MAKE PERMANENT REPAIRS PRIOR TO 01FEB84 OR;
Condition: Unknown
Due 17 October 1983
Resolved 17 October 1983
Unknown
Issued 17 October 1983
Resolved
(REQ. 11 CONTINUED) SUBMIT TEMPORARY REPAIRS TO AS OR ICGB FOR APPROVAL OF ADEQUACY AT DERATED LOAD AND CONDUCT QUADRENIAL SURVEY.
Condition: Unknown
Due 17 October 1983
Resolved 17 October 1983