SALTY LADY is a 1974 passenger vessel (inspected). The Coast Guard has recorded 82 inspections since 1984, most recently in May 2025, along with 107 deficiencies, 1 operational control and 1 casualty investigation in 2010.

Records from 1984 to 2025. Most recent: inspection, 1 May 2025.

Built
1974
Last inspected
1 May 2025
Documentation
Valid · documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

WDK9210
Flag
UNITED STATES
367402020
Maury page id
psix-48034

Inspections, by type

…with no type recorded9
Years with a record 39 calendar years (1984–2025)
The 82 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Passenger Ship class in Maury's sources begin in 1977.

Documentation record

Registered dimensions (L × B × D)54.0 ft × 15.4 ft × 7.1 ft
Registered tonnagegross 43 / net 39
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
BuilderWEST PORT SHIPYARD INC · WESTPORT, WA, UNITED STATES · built 1974
Hull materialFRP (Fiberglass)
PropulsionDiesel Reduction
Hull shapeNot recorded
Hull configurationNot recorded
Hailing portSAN FRANCISCO, CA
Trade endorsementsCoastwise, unrestricted, Fishery, Registry
DocumentationValid · issued 11 March 2026 · expires 28 February 2027
Service, as the file records itPassenger (Inspected)
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it43 - Regulatory (Subpart C or D), Gross Ton
39 - Regulatory (Subpart C or D), Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 September 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.

Radio station licence

WDK9210MMSI 367402020 · active · compulsorily equipped · granted 25 June 2019, expires 25 June 2029
WDE8137MMSI 367402020 · cancelled · compulsorily equipped · granted 31 March 2009, cancelled 24 May 2019
WCY8964MMSI not assigned · expired · compulsorily equipped · granted 22 February 1999, cancelled 25 April 2009
FCC Universal Licensing System ship-station file of 6 September 2026, matched to this hull on its US Official Number. Status and dates are the file’s own. The licensee is not read from the file and is not shown. A lapsed licence’s MMSI is still the number the vessel transmitted under while it was valid.

Inspection history · 82

1 May 2025 Annual Inspection
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 8113380
22 April 2024 Deficiency Check · Annual Inspection
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 7899733
9 November 2023 Drydock Exam · Internal Structural Exam · Deficiency Check · Hull Examination
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 7822647
12 April 2023 Annual Inspection · Deficiency Check
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 7665847
12 December 2022 Administrative Inspection
Administrative · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 7608093
11 April 2022 Annual Inspection
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 7428929
4 November 2021 Drydock Exam · Deficiency Check · Hull Examination · Internal Structural Exam
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 7345036
11 March 2021 In-Service Inspection · Deficiency Check · Plan Review "T" Boat · COI Inspection
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 7154749
7 May 2020 Annual Inspection · Deficiency Check
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 6949466
31 October 2019 Internal Structural Exam · Administrative Inspection · Drydock Exam
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 6846127
6 May 2019 Administrative Inspection · Annual Inspection
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 6677261
6 June 2018 Annual Inspection · Administrative Inspection
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 6419688
27 November 2017 Drydock Exam · Internal Structural Exam · Administrative Inspection
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 6313650
20 June 2017 Administrative Inspection · Annual Inspection
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 6223579
29 November 2015 COI Inspection
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 5771666
18 November 2015 Internal Structural Exam · Drydock Exam
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 5766279
17 May 2014 Annual Inspection · Administrative Inspection
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 4860793
9 December 2011 Simplified Stability Test
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 4203689
23 October 2010 Type not recorded
No type recorded · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 3907440
2 July 2009 Deficiency Check
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 3525533
20 April 2009 Annual Inspection
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 3454904
22 September 2008 Deficiency Check
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 3330138
9 May 2008 Annual Inspection
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 3211459
26 November 2007 Hull Examination
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 3105937
1 November 2007 Type not recorded
No type recorded · Station Golden Gate · USCG Southwest District (CGD-SW) · Activity 3944252
25 May 2007 Deficiency Check
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 2939527
19 April 2007 Annual Inspection
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 2901009
22 March 2006 Deficiency Check · COI Inspection
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 2591534
25 January 2006 Administrative Inspection
Administrative · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 2573005
7 December 2005 Hull Examination
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 2547725
13 June 2005 Administrative Inspection
Administrative · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 2389561
18 March 2005 Administrative Inspection
Administrative · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 2314031
18 May 2004 Annual Inspection · Deficiency Check
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 2071408
19 December 2003 Hull Examination
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1960781
5 June 2003 Deficiency Check
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1807980
1 May 2003 Annual Inspection
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1779783
21 January 2003 In-Service Inspection
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1733425
8 January 2003 Plan Review "T" Boat
Administrative · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1727594
15 November 2002 Plan Review "T" Boat
Administrative · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1706158
18 April 2002 Re-Inspection
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1605992
13 December 2001 Hull Examination
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1415742
7 November 2001 Type not recorded
No type recorded · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1077301
26 March 2001 COI Inspection
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1384713
5 February 2001 Type not recorded
No type recorded · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1384681
30 March 2000 Re-Inspection
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1408496
21 December 1999 Hull Examination
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1446860
19 April 1999 Re-Inspection
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1455695
21 January 1999 Plan Review "T" Boat
Administrative · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 805269
2 September 1998 Administrative
Administrative · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 797687
26 March 1998 COI Inspection
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 787812
21 January 1998 Hull Examination
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1400715
14 January 1998 Type not recorded
No type recorded · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 773245
7 April 1997 Re-Inspection
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1368140
23 May 1996 Type not recorded
No type recorded · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1085179
4 April 1996 Re-Inspection
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1463241
28 November 1995 Hull Examination
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1390153
20 April 1995 Deficiency Check
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1167607
4 April 1995 COI Inspection
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 839519
2 May 1994 Re-Inspection
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 858776
21 December 1993 Hull Examination
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 848228
1 December 1993 Administrative
Administrative · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 851279
14 April 1993 Re-Inspection
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1139560
8 April 1992 COI Inspection
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 947915
4 November 1991 Hull Examination
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1246521
16 April 1991 Re-Inspection
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 929135
14 June 1990 Deficiency Check
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 925411
17 April 1990 Re-Inspection
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 901114
2 March 1990 Deficiency Check
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 928595
17 January 1990 Hull Examination
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1220323
10 April 1989 COI Inspection
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 887974
18 April 1988 Re-Inspection
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1032202
4 December 1987 Hull Examination
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1002267
20 July 1987 Deficiency Check
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1022450
18 May 1987 Deficiency Check
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1336059
21 April 1987 Re-Inspection
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1316466
9 May 1986 Deficiency Check
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 984911
15 April 1986 COI Inspection
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1307341
18 December 1985 Credit Drydock
Administrative · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 994784
27 August 1985 Type not recorded
No type recorded · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1293588
9 August 1985 Deficiency Check
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1290898
2 July 1985 Type not recorded
No type recorded · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1287444
26 December 1984 Type not recorded
No type recorded · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 976604

Deficiency record · 107

09 - Working and Living Conditions › 092 - Working Conditions › Guards - fencing around dangerous machinery parts
Issued 1 May 2025 Resolved
An exposed hazard, such as gears or rotating machinery, must be properly protected by a cover, guard or rail... STBD main engine does not have a guard. Install guard to the satisfaction of the marine inspector. 46 CFR 177.960
Condition: Damaged By Earlier Event
Action required: 16 - Rectify deficiencies w/in 14 days
Due 15 May 2025
Resolved 1 May 2025
Resolution: Operator sent photo of guard installed on stbd main engine. Photo uploaded to deficiency documents.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Machinery space openings
Issued 1 May 2025 Resolved
A penetration in a watertight bulkhead must be... made watertight. 02 Bulkhead penetrations in center void not watertight. Make watertight to the satisfaction of the marine inspector. 46 CFR 179.320(c)
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 15 May 2025
Resolved 2 May 2025
Resolution: Operator sent photos up bulkhead penetrations made watertight. Photos uploaded to deficiency documents.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 22 April 2024 Resolved
Each life jacket must be marked with Type I retroreflective material approved in 46 CFR 164.018 or other standard specified by the Commandant. The arrangement of the retroreflective material applied after March 11, 1996, must be as specified by IMO Resolution A.658(16). 13 life jackets found with unserviceable retroreflective material. Renew retroreflective material to satisfaction of the Marine Inspector. 46 CFR 185.604(h)
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 7 May 2024
Resolved 25 April 2024
Resolution: Received photos of serviced lifejackets.
11 - Life Saving Appliances › N/A - No Subsystem › Rigid liferafts
Issued 22 April 2024 Resolved
Each launching appliance and each survival craft and rescue boat on a vessel must be in good working order and ready for immediate use before the vessel leaves port and at all times when the vessel is underway. Liferafts found with numerous gouges penetrating the body of the raft. Repair in accordance with the manufacturers instructions to the satisfaction of the Marine Inspector. 46 CFR 185.700(a)
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 7 May 2024
Resolved 10 May 2024
Resolution: Liferaft repaired.
11 - Life Saving Appliances › N/A - No Subsystem › Stowage and provision of liferafts
Issued 22 April 2024 Resolved
Life floats, when stowed in tiers, the separate units must be kept apart by spacers. Life floats found without spacers. Install spacers to satisfaction of the Marine Inspector. 46 CFR 180.137(f)
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 7 May 2024
Resolved 25 April 2024
Resolution: Installed plastic spacers inbetween lifefloats.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 22 April 2024 Resolved
Fuel filters fitted with bowls of other than steel construction must be approved by the Commandant and be protected from mechanical damage. Approval of bowls of other than steel construction will specify if a flame shield is required. Installed fuel filters found without flame shields. Install flame shields IAW manufacturer's type approval. 46 CFR 182 (b)(6)
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 7 May 2024
Resolved 10 May 2024
Resolution: Fuel filter flame shield installed.
07 - Fire Safety › N/A - No Subsystem › Fire prevention structural integrity
Issued 22 April 2024 Resolved
Vapor barriers must be provided where insulation of any type is used in spaces where flammable and combustible liquids or vapors are present, such as machinery spaces and paint lockers. 02 penetrations found not to be vapor tight in the forward engine room bulkhead. Restore vapor tight integrity to identified penetrations. 46 CFR 177.405(e)
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 7 May 2024
Resolved 25 April 2024
Resolution: Bulkhead was made vapor tight.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 22 April 2024 Resolved
Strong and effective rudder stops must be provided to prevent jamming and damage to the rudder and its fittings. These stops may be structural or internal to the main steering gear. Rudder stops found to be missing on installed steering gear. Install rudder stops to satisfaction of the Marine Inspector. 46 CFR 182.610(e)
Condition: Design Flaw
Action required: 16 - Rectify deficiencies w/in 14 days
Due 7 May 2024
Resolved 25 April 2024
Resolution: Installed rudder stops.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 22 April 2024 Resolved
Each life jacket must be approved in accordance with either § 160.002, § 160.005, or § 160.055 in subchapter Q of this chapter. 01 Adult PFD found to not be of the correct type. Replaced in the presence of the attending Marine Inspector. 46 CFR 180.71(c)
Condition: Placed in Improper Service
Action required: 10 - Deficiency Rectified
Resolved 23 April 2024
Resolution: Corrected in the presence of the attending Marine Inspector.
05 - Radio Communications › N/A - No Subsystem › Satellite EPIRB 406MHz/1.6GHz
Issued 22 April 2024 Resolved
Each vessel that operates on the high seas, or that operates beyond three miles from the coastline of the Great Lakes, must have on board a FCC Type Accepted Category 1, 406 MHz EPIRB, installed to automatically float free and activate. Vessel's EPIRB hydrostatic release found to be expired. Replaced in the presence of the attending Marine Inspector. 46 CFR 180.64
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Resolved 23 April 2024
Resolution: Replaced in the presence of the attending Marine Inspector.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 12 April 2023 Resolved
The bilge suctions shall be fitted with suitable strainers having an open area not less than three times the area of the bilge pipe. Engine Room and Sewage Void have insufficient bilge strainers. Install suitable strainers to both spaces to satisfaction of Marine Inspector. 46 CFR 182.25-5 "OLD-T"
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 26 April 2023
Resolved 20 June 2023
Resolution: Installed suffecient, metallic bilge strainers to both spaces.
05 - Radio Communications › N/A - No Subsystem › VHF radio installation
Issued 12 April 2023 Resolved
Vessels operated solely within 20 nautical miles of land must be equipped with a VHF-DSC radiotelephone installation meeting the requirements of 80.1101(c)(2. Verify input of MMSI number into VHF radio and link GPS to VHF to allow DSC feature to be operational. 47 CFR 80.905 (a)(1)
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 26 April 2023
Resolved 20 June 2023
Resolution: Installed GPS + MMSI into VHF. Proper DSC operation enabled.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 11 April 2022 Resolved
Each life jacket must be approved in accordance with either § 160.002, § 160.005, or § 160.055 in subchapter Q of this chapter, or other standard specified by the Commandant, including, but not limited to, approval series 160.155 or 160.176. Three Kapok PFD's were deemed unfit for continued use based on requirements listed under Subchapter Q.
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Resolved 11 April 2022
Resolution: Placed new Lifejackets into circulation
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 4 November 2021 Resolved
A bilge suction must be fitted with a suitable strainer having an open area not less than three times the area of the bilge pipe. Forward bilge suction does not have a suitable strainer.
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 18 November 2021
Resolved 4 November 2021
Resolution: Operator sent picture of installed strainer.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 26 March 2021 Resolved
CORK AND BALSA WOOD LIFE JACKETS PREVIOUSLY ON BOARD AN EXISTING VESSEL PRIOR TO MARCH 11, 1996, MAY CONTINUE TO BE USED TO MEET THE REQUIREMENTS OF THIS SECTION UNTIL MARCH 11, 1999, PROVIDED THE LIFE JACKETS ARE MAINTAINED IN GOOD AND SERVICEABLE CONDITION. MI FOUND 02 ADULT AND 02 CHILD LIFE PRESERVERS IN AN UNSERVICEABLE CONDITION. VESSEL IS PERMITTED TO OPERATE WITH AN ALLOWANCE OF 50 ADULT PASSENGERS AND 05 CHILD LIFE PRESERVERS PERSONS ONBOARD RATHER THAN THE COI AMOUNT OF 51 PERSONS (06 CHILD PERSONS) ONBOARD AS A RESULT FROM THE 04 FOUND UNSERVICEABLE LIFE PRESERVERS. VESSEL SUPPLIED MI WITH SERVICEABLE REPLACEMENT LIFE JACKETS; VESSEL IS AUTHORIZED TO FOLLOW COI PASSENGER ALLOWANCE. 46 CFR 180.25-1 (OLD T)
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Resolved 26 March 2021
Resolution: VESSEL SUPPLIED MI WITH SERVICEABLE REPLACEMENT LIFE JACKETS; VESSEL IS AUTHORIZED TO FOLLOW COI PASSENGER ALLOWANCE.
02 - Structural Conditions › N/A - No Subsystem › Closing devices/watertight doors
Issued 26 March 2021 Resolved
THE NUMBER OF PENETRATIONS IN A WATERTIGHT BULKHEAD MUST BE MINIMIZED. A PENETRATE ON IN A WATERTIGHT BULKHEAD MUST BE AS HIGH AND AS FAR INBOARD IN THE BULKHEAD AS PRACTICABLE, AND MADE WATERTIGHT. MI DISCOVERED A 3 INCH PENETRATION ON AFT BULKHEAD IN ENGINE VOID SPACE. OPERATOR INSTALLED A PLATE TO PREVENT WATER FROM ENTERING SPACE FROM PENETRATION. 46 CFR 179.320 (c)
Condition: Invalid
Action required: 17 - Rectify deficiencies prior to departure
Resolved 26 March 2021
Resolution: OPERATOR INSTALLED A PLATE TO PREVENT WATER FROM ENTERING SPACE FROM PENETRATION.
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 26 March 2021 Resolved
AT EACH INSPECTION FOR CERTIFICATION AND AT EVERY OTHER VESSEL INSPECTION ALL OBSERVED UNSAFE PRACTICES, FIRE HAZARDS, AND OTHER HAZARDOUS SITUATIONS MUST BE CORRECTED AL REQUIRED GUARDS AND PROTECTIVE DEVICES MUST BE IN SATISFACTORY CONDITION. MI DISCOVERED AN EXPOSED/LOOSE/UNUSED CABLE IN ENGINE ROOM SPACE CREATING A POTENTIAL FIRE HAZARD. OPERATOR CAPPED/COILED EXPOSED/LOOSE CABLE TO ELIMIATE THE POTENTIAL FIRE HAZARD. 46 CFR 176.830 (a)
Condition: Invalid
Action required: 16 - Rectify deficiencies w/in 14 days
Due 9 April 2021
Resolved 26 March 2021
Resolution: OPERATOR CAPPED/COILED EXPOSED/LOOSE CABLE TO ELIMIATE THE POTENTIAL FIRE HAZARD.
11 - Life Saving Appliances › N/A - No Subsystem › Stowage and provision of liferafts
Issued 7 May 2020 Resolved
If the vessel carries more than one life float or buoyant apparatus , the life floats and buoyant may be grouped and each group secured by a single painter. 03 Life Floats were not secured with a single painter.
Condition: Improper Installation
Action required: 10 - Deficiency Rectified
Due 21 May 2020
Resolved 19 May 2020
Resolution: Operator corrected life float painter arrangement.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 31 October 2019 Resolved
Vessel must be provided with individual bilge lines for each watertight compartment. Individual bilge lines were not labeled for easy operation. Operator corrected on the spot. 46 CFR 182.510(a)
Action required: 10 - Deficiency Rectified
Due 31 October 2019
Resolved 31 October 2019
Resolution: Corrected on the spot.
Lifesaving › Lifefloat › Float-free Link
Issued 6 June 2018 Resolved
Sizing spec tag was missing from the float free link.
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Due 6 June 2018
Resolved 6 June 2018
Resolution: New appropriate sized link was landed on vessel during inspection.
Lifesaving › Hand Flares › Not on Board
Issued 6 June 2018 Resolved
Vessel is missing 4 of its 12 required flares/smoke signals.
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Due 6 June 2018
Resolved 6 June 2018
Resolution: Crew landed 4 red hand flares onboard during the inspection.
Electrical › Electric Supply System (service) › Battery Installation
Issued 6 June 2018 Resolved
Batteries located amidships in the engine room were installed with wing nuts on the terminal connections.
Condition: Improper Installation
Action required: 10 - Deficiency Rectified
Due 6 June 2018
Resolved 6 June 2018
Resolution: Captain had wing nuts removed and replaced with properly sized premanent nuts.
Fire Fighting › Fire Bucket › Lanyard
Issued 20 June 2017 Resolved
Vessel had 02 of 03 required fire buckets onboard. The 02 onboard were not properly marked and did not have lanyards affixed.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 20 June 2017
Resolved 20 June 2017
Resolution: Vessel put additional bucket onboard, properly stenciled all three and affixed lanyards.
Lifesaving › Lifefloat › Floating Electric Waterlight
Issued 20 June 2017 Resolved
Battery for waterlight was expired.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 20 June 2017
Resolved 20 June 2017
Resolution: Vessel rep replaced batteries.
Lifesaving › Lifejacket/PFD (General) › Lights
Issued 20 June 2017 Resolved
Twelve lights on PFD's were expired.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 20 June 2017
Resolved 20 June 2017
Resolution: Vessel rep replaced expired lights.
Operations/Management › Equipment Service/Testing › EPIRB
Issued 17 May 2014 Resolved
Replace EPIRB battery.
Action required: 705 - Other - as specified
Due 19 May 2014
Resolved 12 June 2014
Lifesaving › Lifefloat › Floating Electric Waterlight
Issued 17 May 2014 Resolved
Replace expired batteries on all life floats and ring buoy. Vessel restricted to day time operations.
Action required: 705 - Other - as specified
Resolved 30 May 2014
Fire Fighting › Ventilation Systems › Ducts
Issued 17 May 2014 Resolved
Provide proof of closure to engine room ventilation ducts.
Due 19 June 2014
Resolved 24 May 2014
Electrical › Electric Supply System (service) › Battery Installation
Issued 17 May 2014 Resolved
Properly mount batteries in electrolyte resistant tray.
Due 19 June 2014
Resolved 19 June 2014
Electrical › Electric Supply System (service) › Battery Installation
Issued 17 May 2014 Resolved
Provide protective cover for battery posts.
Due 19 June 2014
Resolved 19 June 2014
Engineering › Bilge Water Management System › Strainer
Issued 20 April 2009 Resolved
Provide strainer on bilge suction in bunk room I.A.W. 46CFR 182.25-5(b).
Action required: 705 - Other - as specified
Due 20 May 2009
Resolved 2 July 2009
Fire Fighting › Ventilation Systems › Ducts
Issued 20 April 2009 Resolved
Provide new ventilation covers for engine room exhaust ventilation.
Action required: 705 - Other - as specified
Due 20 May 2009
Resolved 2 July 2009
Lifesaving › Lifejacket/PFD (Type I) › Condition
Issued 20 April 2009 Resolved
Replace two child size Type I PFD's and three adult size Type I PFD's.
Action required: 705 - Other - as specified
Due 20 May 2009
Resolved 2 July 2009
Lifesaving › Lifefloat › Floating Electric Waterlight
Issued 20 April 2009 Resolved
Renew waterlight on 15 Person lifefloat.
Action required: 705 - Other - as specified
Due 20 May 2009
Resolved 2 July 2009
Navigation › Collision/Grounding Avoidance › Navigation Lights
Issued 20 April 2009 Resolved
Repair stern light, vessel is restricted to daylight operations until completed.
Action required: 705 - Other - as specified
Due 20 May 2009
Resolved 2 July 2009
Deck/Cargo › Mooring/Anchoring › Anchor
Issued 20 April 2009 Resolved
Replace severely deteriorated anchor. Insure new anchor is appropriate size for vessel (46CFR 184.10-1).
Action required: 705 - Other - as specified
Due 20 May 2009
Resolved 2 July 2009
Engineering › Fuel Oil Service System › Filter
Issued 9 May 2008 Resolved
Stop small fuel oil leak on port engine inboard racor fuel filter.
Due 9 June 2008
Resolved 9 May 2008
Lifesaving › Lifejacket/PFD (General) › Quantity
Issued 9 May 2008 Resolved
Provide onboard one adult Type I PFD, vessel is restricted to 48 passengers onboard.
Due 9 June 2008
Resolved 9 May 2008
Construction/Loadline › Penetrations › Gasket
Issued 9 May 2008 Resolved
Make generator compartment hatch watertight, IAW 46 CFR 179.360 (a).
Due 9 June 2008
Resolved 22 September 2008
Lifesaving › Visual Distress Signals (General) › Expired
Issued 9 May 2008 Resolved
Provide onboard required visual distress signals IAW 46 CFR 180.68 (a). Vessel is restricted to voyages no longer than 30 minutes.
Due 9 June 2008
Resolved 9 May 2008
Navigation › Piloting/Steering › Inland Navigation Rules
Issued 19 April 2007 Resolved
Provide copy of Coast Guard rules of the road publication.
Action required: 705 - Other - as specified
Due 19 May 2007
Resolved 25 May 2007
Lifesaving › Lifefloat › Serviceable
Issued 19 April 2007 Resolved
Repair/renew 22-man life float with approved repair kit.
Action required: 705 - Other - as specified
Due 19 May 2007
Resolved 25 May 2007
Lifesaving › Lifefloat › Netting
Issued 19 April 2007 Resolved
Renew line at top of netting on 15-man lifefloat.
Action required: 705 - Other - as specified
Due 19 April 2007
Resolved 19 April 2007
Engineering › Bilge Water Management System › Strainer
Issued 28 December 2005 Resolved
Install new bilge suction strainer in way of forward compartment in accordance with 46 CFR 182.25-5(b).
Action required: 705 - Other - as specified
Due 26 March 2006
Resolved 22 March 2006
Construction/Loadline › Structures › Longitudinal Bulkhead
Issued 28 December 2005 Resolved
Repair dry rot to aft bulkhead in engine room above port shaft.
Action required: 705 - Other - as specified
Due 26 March 2006
Resolved 22 March 2006
Engineering › Fuel Oil Storage/Transfer System › Hose
Issued 28 December 2005 Resolved
Install metallic through bulkhead fittings for both fuel oil return lines in accordance with 46 CFR 182.20-40.
Action required: 705 - Other - as specified
Due 26 March 2006
Resolved 22 March 2006
Lifesaving › Lifebuoys › Self-igniting Lights
Issued 18 May 2004 Resolved
Replace ring buoy float light. Vsl restricted to day light operations until corrected.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 21 May 2004
Resolved 18 May 2004
Communications › Visual Communication › Warning Sign (radio room)
Issued 18 May 2004 Resolved
Provide emergency broadcast placard for pilot house radios.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 30 May 2004
Resolved 24 June 2004
Engineering › Diesel Engine (auxiliary) › Piping (exhaust)
Issued 18 May 2004 Resolved
Replace ship service generator exhaust hose & clamps between discharge side of muffler to overboard fitting.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 30 May 2004
Resolved 24 June 2004
Construction/Loadline › Structures › Transverse Bulkhead
Issued 18 May 2004 Resolved
Abate furring on engine room overhead frames and preserve.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 30 June 2004
Resolved 24 June 2004
Electrical › Electric Supply System (service) › Battery Conductor
Issued 18 May 2004 Resolved
Clean and tighten all starting battery terminals.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 30 May 2004
Resolved 24 June 2004
Lifesaving › Hand Flares › Expired
Issued 18 May 2004 Resolved
[withheld — contains personal information; the deficiency system, dates, and resolution status are shown above]
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 18 May 2004
Resolved 18 May 2004
Accommodation/Occupational Safety › Medical/First Aid › Medicine Chest
Issued 18 May 2004 Resolved
[withheld — contains personal information; the deficiency system, dates, and resolution status are shown above]
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 18 May 2004
Resolved 18 May 2004
Stability › Weathertight Integrity
Issued 19 December 2003 Resolved
Make forward lazzarette bulkhead water tight in way of fuel oil piping penetrations through bulkhead. LEGACY COMPONENT DESC: Bulkhead
Action required: 705 - Other - as specified
Due 31 December 2003
Resolved 19 December 2003
Stability › Unintentional Flooding
Issued 19 December 2003 Resolved
Make hatch to generator compartment water tight. LEGACY COMPONENT DESC: Deck hatch
Action required: 705 - Other - as specified
Due 31 December 2003
Resolved 19 December 2003
Lifesaving › Buoyant Apparatus
Issued 1 May 2003 Resolved
Make all life float and water light painter lines comply with 46 CFR 180.137. LEGACY COMPONENT DESC: Life floats
Action required: 705 - Other - as specified
Due 31 May 2003
Resolved 5 June 2003
Lifesaving › Buoyant Apparatus
Issued 1 May 2003 Resolved
Renew retro-reflective tape for 15 and 22 person life floats. LEGACY COMPONENT DESC: Life float retro-reflective tape
Action required: 705 - Other - as specified
Due 31 May 2003
Resolved 5 June 2003
Communications › Radio Communications
Issued 1 May 2003 Resolved
Provide NOAA EPIRB registration. LEGACY COMPONENT DESC: EPIRB
Action required: 705 - Other - as specified
Due 31 May 2003
Resolved 2 May 2003
Resolution: Received faxed NOAA EPIRB.
Lifesaving › Buoyant Apparatus
Issued 1 May 2003 Resolved
Remove life float weak link quick release clip and secure life float with a permanent securing device per NVIC 1-83. LEGACY COMPONENT DESC: Life float weak links
Action required: 705 - Other - as specified
Due 31 May 2003
Resolved 5 June 2003
Lifesaving › Buoyant Apparatus
Issued 1 May 2003 Resolved
Prior to carriage of passengers, attach #2 and #3 aft life floats as a group to weak link per NVIC 1-83 LEGACY COMPONENT DESC: Life float group
Action required: 705 - Other - as specified
Resolved 1 May 2003
Resolution: Attached weak link.
Lifesaving › Lifebuoys
Issued 1 May 2003 Resolved
Attach water light to life ring per 46 CFR 180. LEGACY COMPONENT DESC: Line
Action required: 705 - Other - as specified
Due 31 May 2003
Resolved 5 June 2003
Electrical › Electrical Distribution System (service)
Issued 1 May 2003 Resolved
Cap or remove dead end wire aft of port fuel tank in lazarette bilge. LEGACY COMPONENT DESC: Wiring
Action required: 705 - Other - as specified
Due 31 May 2003
Resolved 5 June 2003
Electrical › Lighting (service)
Issued 1 May 2003 Resolved
Make lazarette light water tight and remove water from protective cover. LEGACY COMPONENT DESC: Lighting Fixture
Action required: 705 - Other - as specified
Due 31 May 2003
Resolved 5 June 2003
Electrical › Lighting (service)
Issued 1 May 2003 Resolved
Remove receptacle screwed into light socket in lazarette and cap socket. LEGACY COMPONENT DESC: Lighting Fixture
Action required: 705 - Other - as specified
Due 31 May 2003
Resolved 5 June 2003
Fire Fighting › Fixed CO2 Fire Extinguishing System
Issued 1 May 2003 Resolved
Make engine space bulkheads fume tight. LEGACY COMPONENT DESC: Engine space
Action required: 705 - Other - as specified
Due 31 May 2003
Resolved 5 June 2003
Stability › Watertight Integrity
Issued 1 May 2003 Resolved
Make generator space hatch water tight and securable. Also, provide combing drain hose. LEGACY COMPONENT DESC: Hatch
Action required: 705 - Other - as specified
Due 31 May 2003
Resolved 5 June 2003
Electrical › Lighting (service)
Issued 1 May 2003 Resolved
Replace broken port and starboard engine space light bulbs. LEGACY COMPONENT DESC: Lighting Fixture
Action required: 705 - Other - as specified
Due 31 May 2003
Resolved 5 June 2003
Electrical › Lighting (service)
Issued 1 May 2003 Resolved
Provide protective cover for starboard engine space light. LEGACY COMPONENT DESC: Lighting Fixture
Action required: 705 - Other - as specified
Due 31 May 2003
Resolved 5 June 2003
Pollution Prevention/Response › Prevention Equipment
Issued 1 May 2003 Resolved
Properly secure MSD overboard discharge valves per 33 CFR 159.7 and 46 CFR 176.818. LEGACY COMPONENT DESC: Marine Sanitation Device, Type III
Action required: 705 - Other - as specified
Due 31 May 2003
Resolved 5 June 2003
Stability › Watertight Integrity
Issued 1 May 2003 Resolved
Provide water tight cover for collision bulkhead access per 46 CFR 171.085 (h). LEGACY COMPONENT DESC: Collision bulkhead
Action required: 705 - Other - as specified
Due 15 May 2003
Resolved 5 June 2003
Personnel › Certificates/Documents/Licenses
Issued 1 May 2003 Resolved
Provide CPR and First Aid cards for 50% of crew per NVIC 1-91. LEGACY COMPONENT DESC: Certificate, CPR Course Completion
Action required: 705 - Other - as specified
Due 31 May 2003
Resolved 5 June 2003
Navigation › Collision/Grounding Avoidance
Issued 1 May 2003 Resolved
Repair port and starboard navigation lights. LEGACY COMPONENT DESC: Navigation Lights
Action required: 705 - Other - as specified
Due 1 May 2003
Resolved 1 May 2003
Resolution: Replaced bulbs.
Lifesaving › Lifejacket/PFD (Type I) › Lights
Issued 1 May 2003 Resolved
Replaced expired batteries that had expired in 1995 with new non-expired batteries for 24 adult PFDs and 1 child PFD.
Action required: 705 - Other - as specified
Due 1 May 2003
Resolved 1 May 2003
Resolution: Replaced batteries.
Documentation
Issued 4 April 1995 Resolved
PROVIDE FCC RADIO TELE. CERT.
Condition: Unknown
Due 4 May 1995
Resolved 20 April 1995
Lifesaving
Issued 14 April 1993 Resolved
PROVIDE LIGHT FOR ONE ADULT LIFEJACKET
Condition: Unknown
Due 23 April 1993
Resolved 23 April 1993
Navigation
Issued 14 April 1993 Resolved
PROVIDE VESSEL COPY OF RULES OF THE ROAD.
Condition: Unknown
Due 23 April 1993
Resolved 23 April 1993
Navigation
Issued 14 April 1993 Resolved
PROVIDE VESSEL WITH A BELL.
Condition: Unknown
Due 23 April 1993
Resolved 23 April 1993
Engineering
Issued 14 April 1993 Resolved
PROVIDE GUARD OVER PORT ENG. ALTERNATOR.
Condition: Unknown
Due 23 April 1993
Resolved 23 April 1993
Engineering
Issued 17 April 1990 Resolved
PROVIDE BILGE SUCTION STRAINERS WHICH HAVE AN OPEN AREA OF NOT LESS THAN THREE TIMES THE AREA OF THE BILGE SUCTION PIPE, AS PER 46CFR182.25-5, FOR ALL SPACES.
Condition: Unknown
Due 17 April 1990
Resolved 17 April 1990
Navigation
Issued 17 April 1990 Resolved
PROVIDE A DEVIATION CARD FOR THE MAGNETIC COMPASS
Condition: Unknown
Due 17 April 1990
Resolved 17 April 1990
Navigation
Issued 17 April 1990 Resolved
TIGHTEN OR REPAIR THE ANCHOR PLATE FOR THE HYDRAULIC STEERING RAM.
Condition: Unknown
Due 17 April 1990
Resolved 17 April 1990
Engineering
Issued 17 April 1990 Resolved
DRILL & PIN OR DOUBBLE NUT THE THROTTLE AND GEAR SHIFT LINKAGES ON BOTH ENGINES.
Condition: Unknown
Due 17 April 1990
Resolved 17 April 1990
Engineering
Issued 17 April 1990 Resolved
INSTALL BONDING STRAPS ON BOTH FUEL TANK FILL PIPES.
Condition: Unknown
Due 17 April 1990
Resolved 17 April 1990
Accommodation/Occupational Safety
Issued 17 April 1990 Resolved
MARK THE MSD OVERBOARD DISCHARGE VALVE, "DO NOT DISCHARGE IN US WATER"
Condition: Unknown
Due 17 April 1990
Resolved 17 April 1990
Electrical
Issued 17 April 1990 Resolved
PROVIDE PROPER OVERCURRENT PROTECTION IN THE MAIN FEEDER CABLE FROM THE BATTERY BOX TO THE BREAKER BOARD.
Condition: Unknown
Due 17 April 1990
Resolved 17 April 1990
Engineering
Issued 10 April 1989 Resolved
3 PROVIDE SHUT OFF VALVES FOR KEEL COOLER INLET & OUTLET AS CLOSE AS POSSIBLE TO THE HULL OR HARD PIPE TO A LOCATION ABOVE THE WATER LINE.
Condition: Unknown
Due 10 April 1989
Resolved 10 April 1989
Navigation
Issued 10 April 1989 Resolved
1 REPAIR AND PROVE OPERATION OF STERN LIGHT.
Condition: Unknown
Due 10 April 1989
Resolved 10 April 1989
Engineering
Issued 10 April 1989 Resolved
2 PROVIDE REMOTE FUEL SHUTOFFS THAT CAN BE OPERATED FROM OUTSIDE THE FUEL TANK SPACE. (46CFR 182.20-40B3)
Condition: Unknown
Due 10 April 1989
Resolved 10 April 1989
Construction/Loadline
Issued 18 April 1988 Resolved
REPLACE BROKEN WINDOW PORT SIDE BRIDGE.
Condition: Unknown
Due 18 April 1988
Resolved 18 April 1988
Lifesaving
Issued 18 April 1988 Resolved
REPLACE 2 BROKEN OARS FOR 15 PERSON LIFE FLOAT.
Condition: Unknown
Due 18 April 1988
Resolved 18 April 1988
Lifesaving
Issued 18 April 1988 Resolved
RE-STENCIL ALL SIX OARS FOR LIFE FLOATS.
Condition: Unknown
Due 18 April 1988
Resolved 18 April 1988
Lifesaving
Issued 18 April 1988 Resolved
PROVE OPERATION OF EPIRB.
Condition: Unknown
Due 18 April 1988
Resolved 18 April 1988
Lifesaving
Issued 18 April 1988 Resolved
REPLACE 3 WATER LIGHTS ON 3 LIFE PRESERVERS.
Condition: Unknown
Due 18 April 1988
Resolved 18 April 1988
Lifesaving
Issued 18 April 1988 Resolved
REPAIR LIGHT ON RING BUOY.
Condition: Unknown
Due 18 April 1988
Resolved 18 April 1988
Construction/Loadline
Issued 21 April 1987 Resolved
MAKE PERMANENT REPAIRS TO ELECTRIC BILGE PUMP.
Condition: Unknown
Due 21 April 1987
Resolved 21 April 1987
Engineering
Issued 21 April 1987 Resolved
REPLACE/CLEAN FUEL VENT FLAME SCREENS.
Condition: Unknown
Due 21 April 1987
Resolved 21 April 1987
Lifesaving
Issued 15 April 1986 Resolved
THE LIGHTS FOR 8 ADULT LIFE PRESERVERS DID NOT OPERATE.
Condition: Unknown
Due 15 April 1986
Resolved 15 April 1986
Engineering
Issued 15 April 1986 Resolved
REMOTE FUEL SHUTOFFS ARE NOT LABELED AS SUCH.
Condition: Unknown
Due 15 April 1986
Resolved 15 April 1986
Lifesaving
Issued 15 April 1986 Resolved
PROVIDE WATERLIGHT FOR LIFEFLOAT, LIGHT WAS INOPERABLE, VSL RESTRICTED TO DAYLIGHT OPS UNTIL CORRECTED.
Condition: Unknown
Due 15 April 1986
Resolved 15 April 1986
Lifesaving
Issued 15 April 1986 Resolved
LIFEFLOATS ON BOARD ARE FOR 39 PERSONS, THE STABILITY LETTER ALLOWS 49 PASS ON EXPOSED WATERS.COI ALLOWS 49 PASS ON CW ROUTE AND 37 PASS ON OCEANS ROUTE, OWNER DESIRES TO BE CERTIFIED FOR 49 PASS ON OCEANS ROUTE.
Condition: Unknown
Due 15 April 1986
Resolved 15 April 1986
Lifesaving
Issued 15 April 1986 Resolved
BRACKET FOR RING BUOY WATERLIGHT NEEDS TO BE RE-MOUNTED. RING BUOY IS ON WEATHER DECK NEAR ENTRANCE TO PILOTHOUSE BUT THE WATERLIGHT IS MOUNTED INSIDE THE PILOTHOUSE.
Condition: Unknown
Due 15 April 1986
Resolved 15 April 1986
Documentation
Issued 2 July 1985 Resolved
PROVIDE VALID FCC SAFETY CERTIFICATE.
Condition: Unknown
Due 2 July 1985
Resolved 2 July 1985
Navigation
Issued 2 July 1985 Resolved
REMOUNT SINGLE SIDE BAND RADIO.
Condition: Unknown
Due 2 July 1985
Resolved 2 July 1985
Fire Fighting
Issued 2 July 1985 Resolved
REPLACE PORT FUEL VENT FLAME SCREEN.
Condition: Unknown
Due 2 July 1985
Resolved 2 July 1985
Lifesaving
Issued 2 July 1985 Resolved
PROVIDE TWO ADDITIONAL ADULT LIFE JACKETS.
Condition: Unknown
Due 2 July 1985
Resolved 2 July 1985
Documentation
Issued 2 July 1985 Resolved
CONDUCT STABILITY TEST FOR 100 MILE ROUTE NLT 30 NOV 85
Condition: Unknown
Due 2 July 1985
Resolved 2 July 1985
Fire Fighting
Issued 2 July 1985 Resolved
PROVIDE SUFFICIENT HOSE FOR HAND PUMP.
Condition: Unknown
Due 2 July 1985
Resolved 2 July 1985

Casualty record · 1

27 May 2010Routine · role: Involved in a Marine Casualty · activity 3749538
Each line is an incident investigation the Coast Guard recorded with this hull among the vessels involved, with the date and the classification the Coast Guard gave it, and the bridge, lock or dam the investigation names where it names one. Involvement is not fault. The investigation narrative is not published. Source: IIR, through 2026.

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.