SALTY LADY

SALTY LADY is a 1974 passenger vessel (inspected). The Coast Guard has recorded 14 inspections since 2017, most recently in May 2025, along with 25 deficiencies, 1 operational control and 1 casualty investigation in 2010.

Records from 2010 to 2025. Most recent: inspection, 1 May 2025.

Built
1974
Last inspected
1 May 2025
Documentation
Valid · documentation file of 10 August 2026
Controls
None recorded without a removal date

Coast Guard record current through 23 August 2026, retrieved 5 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Passenger Ship class in Maury's sources begin in 2016.

Inspection record

Last inspected 1 May 2025
Operational controls None recorded without a removal date
Years with a record 9 calendar years (2017–2025)
Every line above is a count of records the US Coast Guard wrote, or a date it recorded. A blank resolution means none was recorded in this data; it does not establish that a deficiency is outstanding. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Identity

WDK9210
Flag
UNITED STATES
Maury page id
psix-48034

Documentation record

Registered dimensions (L × B × D)54.0 ft × 15.4 ft × 7.1 ft
Registered tonnagegross 43 / net 39
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
BuilderWEST PORT SHIPYARD INC · WESTPORT, WA, UNITED STATES · built 1974
Hull materialFRP (Fiberglass)
PropulsionDiesel Reduction
Hull shapeUNSPECIFIED
Hull configurationUNSPECIFIED
Hailing portSAN FRANCISCO, CA
Trade endorsementsCoastwise, unrestricted, Fishery, Registry
DocumentationValid · issued 11 March 2026 · expires 28 February 2027
Service, as the file records itPassenger (Inspected)
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it43 - Regulatory (Subpart C or D), Gross Ton
39 - Regulatory (Subpart C or D), Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 August 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.
Vessel history report
Every record for this hull, in one document — $299

Every recorded inspection, 2016 to 2026 for this class, in one chronology · every deficiency, with system, dates and resolution · operational controls imposed and removed · every name this hull has been recorded under · the vessels it was inspected alongside, and when · how its record compares with hulls of similar age and size, as a fact about the population and never a judgement about this vessel.

Read one first, in full: a forty-year chronology · a hull that changed operators four times · the sparse case, shown as an example, not for sale.

This report is in development and is not for sale yet. There is no date, and nothing is charged. Leave an email and we will tell you when it exists, once.

Inspection history · 14

1 May 2025 Annual Inspection
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 8113380
22 April 2024 Deficiency Check · Annual Inspection
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 7899733
9 November 2023 Drydock Exam · Internal Structural Exam · Deficiency Check · Hull Examination
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 7822647
12 April 2023 Annual Inspection · Deficiency Check
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 7665847
12 December 2022 Administrative Inspection
Administrative · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 7608093
11 April 2022 Annual Inspection
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 7428929
4 November 2021 Drydock Exam · Deficiency Check · Hull Examination · Internal Structural Exam
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 7345036
11 March 2021 In-Service Inspection · Deficiency Check · Plan Review "T" Boat · COI Inspection
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 7154749
7 May 2020 Annual Inspection · Deficiency Check
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 6949466
31 October 2019 Internal Structural Exam · Administrative Inspection · Drydock Exam
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 6846127
6 May 2019 Administrative Inspection · Annual Inspection
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 6677261
6 June 2018 Annual Inspection · Administrative Inspection
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 6419688
27 November 2017 Drydock Exam · Internal Structural Exam · Administrative Inspection
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 6313650
20 June 2017 Administrative Inspection · Annual Inspection
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 6223579

Deficiency record · 25

09 - Working and Living Conditions › 092 - Working Conditions › Guards - fencing around dangerous machinery parts
Issued 1 May 2025 Resolved
An exposed hazard, such as gears or rotating machinery, must be properly protected by a cover, guard or rail... STBD main engine does not have a guard. Install guard to the satisfaction of the marine inspector. 46 CFR 177.960
Condition: Damaged By Earlier Event
Action required: 16 - Rectify deficiencies w/in 14 days
Due 15 May 2025
Resolved 1 May 2025
Resolution: Operator sent photo of guard installed on stbd main engine. Photo uploaded to deficiency documents.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Machinery space openings
Issued 1 May 2025 Resolved
A penetration in a watertight bulkhead must be... made watertight. 02 Bulkhead penetrations in center void not watertight. Make watertight to the satisfaction of the marine inspector. 46 CFR 179.320(c)
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 15 May 2025
Resolved 2 May 2025
Resolution: Operator sent photos up bulkhead penetrations made watertight. Photos uploaded to deficiency documents.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 22 April 2024 Resolved
Each life jacket must be marked with Type I retroreflective material approved in 46 CFR 164.018 or other standard specified by the Commandant. The arrangement of the retroreflective material applied after March 11, 1996, must be as specified by IMO Resolution A.658(16). 13 life jackets found with unserviceable retroreflective material. Renew retroreflective material to satisfaction of the Marine Inspector. 46 CFR 185.604(h)
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 7 May 2024
Resolved 25 April 2024
Resolution: Received photos of serviced lifejackets.
11 - Life Saving Appliances › N/A - No Subsystem › Rigid liferafts
Issued 22 April 2024 Resolved
Each launching appliance and each survival craft and rescue boat on a vessel must be in good working order and ready for immediate use before the vessel leaves port and at all times when the vessel is underway. Liferafts found with numerous gouges penetrating the body of the raft. Repair in accordance with the manufacturers instructions to the satisfaction of the Marine Inspector. 46 CFR 185.700(a)
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 7 May 2024
Resolved 10 May 2024
Resolution: Liferaft repaired.
11 - Life Saving Appliances › N/A - No Subsystem › Stowage and provision of liferafts
Issued 22 April 2024 Resolved
Life floats, when stowed in tiers, the separate units must be kept apart by spacers. Life floats found without spacers. Install spacers to satisfaction of the Marine Inspector. 46 CFR 180.137(f)
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 7 May 2024
Resolved 25 April 2024
Resolution: Installed plastic spacers inbetween lifefloats.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 22 April 2024 Resolved
Fuel filters fitted with bowls of other than steel construction must be approved by the Commandant and be protected from mechanical damage. Approval of bowls of other than steel construction will specify if a flame shield is required. Installed fuel filters found without flame shields. Install flame shields IAW manufacturer's type approval. 46 CFR 182 (b)(6)
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 7 May 2024
Resolved 10 May 2024
Resolution: Fuel filter flame shield installed.
07 - Fire Safety › N/A - No Subsystem › Fire prevention structural integrity
Issued 22 April 2024 Resolved
Vapor barriers must be provided where insulation of any type is used in spaces where flammable and combustible liquids or vapors are present, such as machinery spaces and paint lockers. 02 penetrations found not to be vapor tight in the forward engine room bulkhead. Restore vapor tight integrity to identified penetrations. 46 CFR 177.405(e)
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 7 May 2024
Resolved 25 April 2024
Resolution: Bulkhead was made vapor tight.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 22 April 2024 Resolved
Strong and effective rudder stops must be provided to prevent jamming and damage to the rudder and its fittings. These stops may be structural or internal to the main steering gear. Rudder stops found to be missing on installed steering gear. Install rudder stops to satisfaction of the Marine Inspector. 46 CFR 182.610(e)
Condition: Design Flaw
Action required: 16 - Rectify deficiencies w/in 14 days
Due 7 May 2024
Resolved 25 April 2024
Resolution: Installed rudder stops.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 22 April 2024 Resolved
Each life jacket must be approved in accordance with either § 160.002, § 160.005, or § 160.055 in subchapter Q of this chapter. 01 Adult PFD found to not be of the correct type. Replaced in the presence of the attending Marine Inspector. 46 CFR 180.71(c)
Condition: Placed in Improper Service
Action required: 10 - Deficiency Rectified
Resolved 23 April 2024
Resolution: Corrected in the presence of the attending Marine Inspector.
05 - Radio Communications › N/A - No Subsystem › Satellite EPIRB 406MHz/1.6GHz
Issued 22 April 2024 Resolved
Each vessel that operates on the high seas, or that operates beyond three miles from the coastline of the Great Lakes, must have on board a FCC Type Accepted Category 1, 406 MHz EPIRB, installed to automatically float free and activate. Vessel's EPIRB hydrostatic release found to be expired. Replaced in the presence of the attending Marine Inspector. 46 CFR 180.64
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Resolved 23 April 2024
Resolution: Replaced in the presence of the attending Marine Inspector.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 12 April 2023 Resolved
The bilge suctions shall be fitted with suitable strainers having an open area not less than three times the area of the bilge pipe. Engine Room and Sewage Void have insufficient bilge strainers. Install suitable strainers to both spaces to satisfaction of Marine Inspector. 46 CFR 182.25-5 "OLD-T"
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 26 April 2023
Resolved 20 June 2023
Resolution: Installed suffecient, metallic bilge strainers to both spaces.
05 - Radio Communications › N/A - No Subsystem › VHF radio installation
Issued 12 April 2023 Resolved
Vessels operated solely within 20 nautical miles of land must be equipped with a VHF-DSC radiotelephone installation meeting the requirements of 80.1101(c)(2. Verify input of MMSI number into VHF radio and link GPS to VHF to allow DSC feature to be operational. 47 CFR 80.905 (a)(1)
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 26 April 2023
Resolved 20 June 2023
Resolution: Installed GPS + MMSI into VHF. Proper DSC operation enabled.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 11 April 2022 Resolved
Each life jacket must be approved in accordance with either § 160.002, § 160.005, or § 160.055 in subchapter Q of this chapter, or other standard specified by the Commandant, including, but not limited to, approval series 160.155 or 160.176. Three Kapok PFD's were deemed unfit for continued use based on requirements listed under Subchapter Q.
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Resolved 11 April 2022
Resolution: Placed new Lifejackets into circulation
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 4 November 2021 Resolved
A bilge suction must be fitted with a suitable strainer having an open area not less than three times the area of the bilge pipe. Forward bilge suction does not have a suitable strainer.
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 18 November 2021
Resolved 4 November 2021
Resolution: Operator sent picture of installed strainer.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 26 March 2021 Resolved
CORK AND BALSA WOOD LIFE JACKETS PREVIOUSLY ON BOARD AN EXISTING VESSEL PRIOR TO MARCH 11, 1996, MAY CONTINUE TO BE USED TO MEET THE REQUIREMENTS OF THIS SECTION UNTIL MARCH 11, 1999, PROVIDED THE LIFE JACKETS ARE MAINTAINED IN GOOD AND SERVICEABLE CONDITION. MI FOUND 02 ADULT AND 02 CHILD LIFE PRESERVERS IN AN UNSERVICEABLE CONDITION. VESSEL IS PERMITTED TO OPERATE WITH AN ALLOWANCE OF 50 ADULT PASSENGERS AND 05 CHILD LIFE PRESERVERS PERSONS ONBOARD RATHER THAN THE COI AMOUNT OF 51 PERSONS (06 CHILD PERSONS) ONBOARD AS A RESULT FROM THE 04 FOUND UNSERVICEABLE LIFE PRESERVERS. VESSEL SUPPLIED MI WITH SERVICEABLE REPLACEMENT LIFE JACKETS; VESSEL IS AUTHORIZED TO FOLLOW COI PASSENGER ALLOWANCE. 46 CFR 180.25-1 (OLD T)
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Resolved 26 March 2021
Resolution: VESSEL SUPPLIED MI WITH SERVICEABLE REPLACEMENT LIFE JACKETS; VESSEL IS AUTHORIZED TO FOLLOW COI PASSENGER ALLOWANCE.
02 - Structural Conditions › N/A - No Subsystem › Closing devices/watertight doors
Issued 26 March 2021 Resolved
THE NUMBER OF PENETRATIONS IN A WATERTIGHT BULKHEAD MUST BE MINIMIZED. A PENETRATE ON IN A WATERTIGHT BULKHEAD MUST BE AS HIGH AND AS FAR INBOARD IN THE BULKHEAD AS PRACTICABLE, AND MADE WATERTIGHT. MI DISCOVERED A 3 INCH PENETRATION ON AFT BULKHEAD IN ENGINE VOID SPACE. OPERATOR INSTALLED A PLATE TO PREVENT WATER FROM ENTERING SPACE FROM PENETRATION. 46 CFR 179.320 (c)
Condition: Invalid
Action required: 17 - Rectify deficiencies prior to departure
Resolved 26 March 2021
Resolution: OPERATOR INSTALLED A PLATE TO PREVENT WATER FROM ENTERING SPACE FROM PENETRATION.
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 26 March 2021 Resolved
AT EACH INSPECTION FOR CERTIFICATION AND AT EVERY OTHER VESSEL INSPECTION ALL OBSERVED UNSAFE PRACTICES, FIRE HAZARDS, AND OTHER HAZARDOUS SITUATIONS MUST BE CORRECTED AL REQUIRED GUARDS AND PROTECTIVE DEVICES MUST BE IN SATISFACTORY CONDITION. MI DISCOVERED AN EXPOSED/LOOSE/UNUSED CABLE IN ENGINE ROOM SPACE CREATING A POTENTIAL FIRE HAZARD. OPERATOR CAPPED/COILED EXPOSED/LOOSE CABLE TO ELIMIATE THE POTENTIAL FIRE HAZARD. 46 CFR 176.830 (a)
Condition: Invalid
Action required: 16 - Rectify deficiencies w/in 14 days
Due 9 April 2021
Resolved 26 March 2021
Resolution: OPERATOR CAPPED/COILED EXPOSED/LOOSE CABLE TO ELIMIATE THE POTENTIAL FIRE HAZARD.
11 - Life Saving Appliances › N/A - No Subsystem › Stowage and provision of liferafts
Issued 7 May 2020 Resolved
If the vessel carries more than one life float or buoyant apparatus , the life floats and buoyant may be grouped and each group secured by a single painter. 03 Life Floats were not secured with a single painter.
Condition: Improper Installation
Action required: 10 - Deficiency Rectified
Due 21 May 2020
Resolved 19 May 2020
Resolution: Operator corrected life float painter arrangement.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 31 October 2019 Resolved
Vessel must be provided with individual bilge lines for each watertight compartment. Individual bilge lines were not labeled for easy operation. Operator corrected on the spot. 46 CFR 182.510(a)
Action required: 10 - Deficiency Rectified
Due 31 October 2019
Resolved 31 October 2019
Resolution: Corrected on the spot.
Lifesaving › Lifefloat › Float-free Link
Issued 6 June 2018 Resolved
Sizing spec tag was missing from the float free link.
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Due 6 June 2018
Resolved 6 June 2018
Resolution: New appropriate sized link was landed on vessel during inspection.
Lifesaving › Hand Flares › Not on Board
Issued 6 June 2018 Resolved
Vessel is missing 4 of its 12 required flares/smoke signals.
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Due 6 June 2018
Resolved 6 June 2018
Resolution: Crew landed 4 red hand flares onboard during the inspection.
Electrical › Electric Supply System (service) › Battery Installation
Issued 6 June 2018 Resolved
Batteries located amidships in the engine room were installed with wing nuts on the terminal connections.
Condition: Improper Installation
Action required: 10 - Deficiency Rectified
Due 6 June 2018
Resolved 6 June 2018
Resolution: Captain had wing nuts removed and replaced with properly sized premanent nuts.
Fire Fighting › Fire Bucket › Lanyard
Issued 20 June 2017 Resolved
Vessel had 02 of 03 required fire buckets onboard. The 02 onboard were not properly marked and did not have lanyards affixed.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 20 June 2017
Resolved 20 June 2017
Resolution: Vessel put additional bucket onboard, properly stenciled all three and affixed lanyards.
Lifesaving › Lifefloat › Floating Electric Waterlight
Issued 20 June 2017 Resolved
Battery for waterlight was expired.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 20 June 2017
Resolved 20 June 2017
Resolution: Vessel rep replaced batteries.
Lifesaving › Lifejacket/PFD (General) › Lights
Issued 20 June 2017 Resolved
Twelve lights on PFD's were expired.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 20 June 2017
Resolved 20 June 2017
Resolution: Vessel rep replaced expired lights.

Casualty record · 1

27 May 2010Routine · role: Involved in a Marine Casualty · activity 3749538