Records from 1985 to 2003. Most recent: inspection, 13 September 2003.
Documentation record
Registered dimensions (L × B × D)48.9 ft × 19.1 ft × 2.9 ft
Registered tonnagegross 32 / net 25
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
Builderbuilder not recorded · TITUSVILLE FL · built 1974
Hull materialFRP (Fiberglass)
PropulsionDiesel Reduction
Hull shapeNot recorded
Hull configurationNot recorded
Hailing portBRIDGEPORT, CT
Trade endorsementsCoastwise, unrestricted
DocumentationExpired · issued 30 June 2004
Service, as the file records itPassenger (Inspected)
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it32 - Regulatory (Subpart C or D), Gross Ton
25 - Regulatory (Subpart C or D), Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 September 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.
A report is not offered for this hull: Its record holds only 2 of the seven kinds of material a report is built from: inspections, deficiencies, operational controls, tow-unit appearances, casualty records, dimensions and documentation. That is a statement about the record, not about the vessel. Reports.
Inspection history · 16
13 September 2003
Type not recorded
No type recorded · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1908478
8 February 1994
Administrative
Administrative · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 853452
22 August 1991
Type not recorded
No type recorded · COTP NEW YORK · USCG Northeast District (CGD-NE) · Activity 653171
14 May 1991
Administrative
Administrative · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1247513
8 August 1990
Hull Examination
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 922409
2 August 1990
Deficiency Check
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 919879
15 December 1989
Re-Inspection
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1243277
3 October 1989
Administrative
Administrative · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1333885
19 December 1988
COI Inspection
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1203371
28 November 1988
Hull Examination
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1203350
3 June 1988
Deficiency Check
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1034245
19 January 1988
COI Inspection
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1204862
21 August 1987
Hull Examination
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1334586
21 August 1985
Type not recorded
No type recorded · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 993083
12 June 1985
COI Inspection
Physical examination · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 1299409
4 April 1985
Credit Drydock
Administrative · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 1299773
Documentation
Issued 2 August 1990
Resolved
[withheld — contains personal information; the deficiency system, dates, and resolution status are shown above]
Condition: Unknown
Due 2 August 1990
Resolved 2 August 1990
Engineering
Issued 21 August 1987
Resolved
REMOVE NYLON THROUGH FITTINGS FOR V-DRIVE OVERBOARD DISCHARGE COOLING LINES ON THE PORT & STBD V-DRIVES. INSTALL BRONZE/MARINE EQUIVALENT THROUGH HULL FITTINGS WITH CHECK VALVES. INSURE HOSE CONNECTIONS ARE DOUBLE HOSE CLAMPED.
Condition: Unknown
Due 21 August 1987
Resolved 21 August 1987
Construction/Loadline
Issued 21 August 1987
Resolved
RENEW PORT & STBD RUDDER FOUNDATION FASTENERS AT VESSEL HULL.
Condition: Unknown
Due 21 August 1987
Resolved 21 August 1987
Engineering
Issued 21 August 1987
Resolved
RENEW PORT & STBD STUFFING TUBE CLAMPS FOR THE PORT & STBD SHAFTING.
Condition: Unknown
Due 21 August 1987
Resolved 21 August 1987
Construction/Loadline
Issued 21 August 1987
Resolved
REPAIR STBD FAN TUNNEL AFT WALL IN WAY OF FIBERGLASS REPAIR PATCH. PRIOR TO VESSEL BEING WATERBORNE.
Condition: Unknown
Due 21 August 1987
Resolved 21 August 1987
Engineering
Issued 21 August 1987
Resolved
REMOVE NYLON THROUGH HULL FITTINGS FOR ALL SIX (6) BILGE OVERBOARD DISCHARGE LINES. INSTALL BRONZE/MARINE EQUIVALENT WITH CHECK VALVES IN THE BILGE SYSTEM AT THE VESSEL HULL. PROVE BILGE PUMP OPERATION.
Condition: Unknown
Due 21 August 1987
Resolved 21 August 1987
Lifesaving
Issued 12 June 1985
Resolved
PROVIDE AND INSTALL PAINTERS FOR BUOYANT APPARATUS AS DETAILED IN NVIC 1-83
Condition: Unknown
Due 12 June 1985
Resolved 12 June 1985
Engineering
Issued 12 June 1985
Resolved
CONDUCT OPERATIONAL TEST OF VESSEL IN PRESENCE OF U.S. COAST GUARD MARINE INSPECTOR; ALONG THE OPERATIONAL ROUTE BOSTON, MA. TO HINGHAM, MA. AND RETURN.
Condition: Unknown
Due 12 June 1985
Resolved 12 June 1985
Lifesaving
Issued 12 June 1985
Resolved
PROVIDE AND INSTALL SUFFICIENT U.S.C.G. APPROVED BUOYANT APPARATUS FOR THE TOTAL NUMBER OF PERSONS ALLOWED.
Condition: Unknown
Due 12 June 1985
Resolved 12 June 1985
Engineering
Issued 12 June 1985
Resolved
MAKE OPERATIONAL FUEL SHUT OFF VALVE FOR FORWARD FUEL TANK AND STENCIL SAME
Condition: Unknown
Due 12 June 1985
Resolved 12 June 1985
Documentation
Issued 12 June 1985
Resolved
PROVIDE ON BOARD MINIMUM OF ONE (1) COPY OF MANUFACTURER'S OPERATING MANUAL.
Condition: Unknown
Due 12 June 1985
Resolved 12 June 1985
Documentation
Issued 12 June 1985
Resolved
VESSEL DOCUMENT EXPIRED.
Condition: Unknown
Due 12 June 1985
Resolved 12 June 1985
Navigation
Issued 12 June 1985
Resolved
PROVIDE AND INSTALL U.S.C.G. APPROVED FLASHING YELLOW LIGHT AND WHITE ANCHOR LIGHTS.
Condition: Unknown
Due 12 June 1985
Resolved 12 June 1985
Accommodation/Occupational Safety
Issued 12 June 1985
Resolved
REMOVE MARINE SANITATION DEVICE (MSD) AND INSTALL DEVICE APPROVED FOR USE ON INSPECTED VESSELS.
Condition: Unknown
Due 12 June 1985
Resolved 12 June 1985
Engineering
Issued 12 June 1985
Resolved
STENCIL REMOTE SHUT OFF VALVE FOR AFTER FUEL TANKS.
Condition: Unknown
Due 12 June 1985
Resolved 12 June 1985