Records from 1986 to 2012. Most recent: inspection, 28 June 2012.
Inspection history · 54
28 June 2012
COI Inspection · Hull Examination
Physical examination · Sector Columbia River · USCG Northwest District (CGD-NW) · Activity 4224335
6 January 2012
Administrative Inspection
Administrative · Sector Columbia River · USCG Northwest District (CGD-NW) · Activity 4219980
13 January 2010
Hull Examination
Physical examination · Sector Portland · USCG Northwest District (CGD-NW) · Activity 3664050
5 June 2008
Annual Inspection
Physical examination · Sector Portland · USCG Northwest District (CGD-NW) · Activity 3226662
27 November 2007
Hull Examination
Physical examination · Sector Portland · USCG Northwest District (CGD-NW) · Activity 3091198
26 April 2007
COI Inspection
Physical examination · Sector Portland · USCG Northwest District (CGD-NW) · Activity 2905433
7 June 2006
Annual Inspection
Physical examination · Sector Portland · USCG Northwest District (CGD-NW) · Activity 2674260
21 November 2005
Hull Examination
Physical examination · Sector Portland · USCG Northwest District (CGD-NW) · Activity 2538440
6 May 2005
Deficiency Check · Annual Inspection
Physical examination · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 2337257
9 June 2004
Annual Inspection
Physical examination · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 2085445
21 November 2003
Deficiency Check · Hull Examination
Physical examination · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 1950449
1 May 2003
Annual Inspection
Physical examination · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 1777775
22 April 2002
Deficiency Check · COI Inspection
Physical examination · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 1606444
21 March 2002
Hull Examination
Physical examination · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 1493115
11 June 2001
Administrative
Administrative · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 1066858
1 May 2001
Type not recorded
No type recorded · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 1454941
27 March 2001
Annual Inspection
Physical examination · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 1469028
31 January 2001
Type not recorded
No type recorded · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 1056493
4 May 2000
Annual Inspection
Physical examination · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 1048634
26 April 2000
Hull Examination
Physical examination · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 817638
14 September 1999
Deficiency Check
Physical examination · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 784752
2 June 1999
Administrative
Administrative · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 804817
17 May 1999
COI Inspection
Physical examination · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 1369168
8 September 1998
Examination of Repairs
Physical examination · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 1465417
28 August 1998
Type not recorded
No type recorded · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 188227
3 August 1998
Type not recorded
No type recorded · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 60878
23 June 1998
Administrative
Administrative · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 792938
6 May 1998
Hull Examination · Re-Inspection
Physical examination · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 1394940
3 June 1997
Deficiency Check
Physical examination · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 1109791
29 April 1997
Re-Inspection
Physical examination · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 1418156
14 May 1996
COI Inspection · Hull Examination
Physical examination · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 1392464
22 February 1996
Type not recorded
No type recorded · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 1400300
17 May 1995
Deficiency Check
Physical examination · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 924681
20 April 1995
Type not recorded
No type recorded · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 1435620
14 February 1995
Re-Inspection
Physical examination · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 1444952
21 April 1994
Deficiency Check
Physical examination · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 856954
18 March 1994
Re-Inspection · Hull Examination
Physical examination · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 1379932
15 October 1993
Administrative
Administrative · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 1145887
26 February 1993
COI Inspection
Physical examination · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 1379753
8 June 1992
Deficiency Check
Physical examination · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 956636
19 March 1992
COI Inspection · Hull Examination
Physical examination · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 1266873
18 March 1991
Re-Inspection
Physical examination · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 1238857
17 October 1990
Deficiency Check
Physical examination · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 1223464
9 October 1990
Hull Examination
Physical examination · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 911490
12 March 1990
Re-Inspection
Physical examination · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 923406
3 April 1989
Deficiency Check
Physical examination · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 1345655
9 March 1989
Hull Examination · COI Inspection
Physical examination · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 1209307
18 November 1988
Drydock Extension
Administrative · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 893363
8 March 1988
Re-Inspection
Physical examination · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 990138
4 June 1987
Administrative
Administrative · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 1027267
27 April 1987
Deficiency Check
Physical examination · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 1024344
5 March 1987
Hull Examination · Re-Inspection
Physical examination · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 1329604
3 September 1986
Type not recorded
No type recorded · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 1314720
11 March 1986
COI Inspection
Physical examination · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 999010
Engineering › Diesel Engine (propulsion-reduction gear) › Bedplate
Issued 6 November 2007
Resolved
Renew engine mount rubber insulators or renew mounts as needed. Provide service reports and digital photos of engine mounts, prior to the completion of credit drydock.
Due 30 November 2007
Resolved 27 November 2007
Resolution: New mounts installed and tested.
Engineering › Shafting/Propeller Arrangements › Bearing
Issued 6 November 2007
Resolved
Complete repairs to shaft to include renewal of cutlass bearing and shaft packing assembly. Pprovide service reports for shaft to include digital photos, prior to the completion of credit drydock.
Due 30 November 2007
Resolved 27 November 2007
Resolution: Shaft repairs, bearing and shaft seal installation complete.
Engineering › Reduction Gearing/Clutches › Oil Spray
Issued 5 May 2005
Resolved
Renew reduction gear hose damaged by the alternator belts. Provide a protected installation to prevent recurrence of damage, prior to the carriage of passengers.
Due 5 June 2005
Resolved 6 May 2005
Resolution: Notified via e-mail that hose has been renewed. Will verify on 25 MAY05.
Engineering › Shafting/Propeller Arrangements › Bearing
Issued 19 November 2003
Resolved
Renew aft cutlass bearing.
Due 21 November 2003
Resolved 21 November 2003
Fire Fighting › Fixed Halon Fire Extinguishing System
Issued 22 April 2002
Resolved
Demonstrate proper operation of fixed halon fire fighting system overide switch to the satisfaction of an attending marine inspector prior to carriage of passengers. LEGACY COMPONENT DESC: Operating Controls
Due 22 May 2002
Resolved 6 May 2002
Engineering › Bilge Water Management System
Issued 22 April 2002
Resolved
Demonstrate proper operation of all high level bilge alarms both visual and audible indicators to the satisfaction of an attending marine inspector prior to carriage of passengers. LEGACY COMPONENT DESC: Interface Detector
Due 22 May 2002
Resolved 6 May 2002
Operations/Management › Drills/Instruction
Issued 22 April 2002
Resolved
Perform operational test of vessel's electronic navigation gear and an underway man overboard/fire drill to the satisfaction of an attending marine inspector prior to carriage of passengers.
Due 22 May 2002
Resolved 6 May 2002
Lifesaving › Lifebuoys
Issued 22 April 2002
Resolved
Renew 3-6 foot detachable lanyard for life ring float light. LEGACY COMPONENT DESC: Buoyant Lifeline
Due 22 May 2002
Resolved 6 May 2002
Construction/Loadline › Penetrations
Issued 21 March 2002
Resolved
Renew bolts holding the scuttle plug on the forward starboard side with new silicone bronze screws and bolts. LEGACY COMPONENT DESC: Bottom Plug
Condition: Unknown
Due 21 April 2002
Resolved 22 April 2002
Construction/Loadline › Structures
Issued 21 March 2002
Resolved
Remove the cracked 6 inch port light on the forward starboard end of the cabin and replace with a fiberglass insert. LEGACY COMPONENT DESC: Port lights
Condition: Damaged By Earlier Event
Due 21 April 2002
Resolved 22 April 2002
Resolution: Verified installation of new fiberglass port light.
Engineering › Steering Gear System
Issued 21 March 2002
Resolved
Prove proper operation of steering system after new rudder is installed. LEGACY COMPONENT DESC: Working assy
Condition: Damaged By Earlier Event
Due 21 April 2002
Resolved 22 April 2002
Resolution: Witnessed successfull test of steering system.
Engineering › Steering Gear System
Issued 21 March 2002
Resolved
Renew clamps holding steering cable in the aft steering compartment. Renew the brackets holding the cable pulleys assembly. LEGACY COMPONENT DESC: Trunnion Block
Condition: Improper/Lack of Maintenance
Due 21 April 2002
Resolved 22 April 2002
Resolution: Verifed installation of fabricated FRP clamps securing steering cable guides.
Navigation
Issued 17 May 1999
Resolved
Repair compass light. Operations limited to daylight only until corrected.
Condition: Unknown
Due 17 May 1999
Resolved 17 May 1999
Lifesaving
Issued 17 May 1999
Resolved
Provide written drug testing policy, employee assistance program, and management information system (MIS) submittal.
Condition: Unknown
Due 17 May 1999
Resolved 17 May 1999
Electrical
Issued 17 May 1999
Resolved
Remove all wire nuts in electrical panel and restroom, and replace with proper pressure type connectors.
Condition: Unknown
Due 17 May 1999
Resolved 17 May 1999
Lifesaving
Issued 17 May 1999
Resolved
Mark lifejacket stowage areas with capacities and child lifejacket stowage locations.
Condition: Unknown
Due 17 May 1999
Resolved 17 May 1999
Lifesaving
Issued 17 May 1999
Resolved
Mark the lifering with the vessel's name.
Condition: Unknown
Due 17 May 1999
Resolved 17 May 1999
Fire Fighting
Issued 17 May 1999
Resolved
Seal aft bulkhead openings in engine compartment, or provide a fixed firefighting system with sufficient capacity for both the engine compartment and lazarette.
Condition: Unknown
Due 17 May 1999
Resolved 17 May 1999
Fire Fighting
Issued 17 May 1999
Resolved
Complete installation of the fixed firefighting system, and make available for inspection.
Condition: Unknown
Due 17 May 1999
Resolved 17 May 1999
Engineering
Issued 17 May 1999
Resolved
Repair and prove proper operation of emergency fuel shutoff.
Condition: Unknown
Due 17 May 1999
Resolved 17 May 1999
Unknown
Issued 6 May 1998
Resolved
PROVIDE PROPER FCC RADIO INSTALLATION SAFETY CERTIFICATE.
Condition: Unknown
Due 6 May 1998
Resolved 6 May 1998
Accommodation/Occupational Safety
Issued 29 April 1997
Resolved
MAKE PROPER REPAIRS TO STBD SIDE BENCH SEAT IN PASSENGER CABIN.
Condition: Unknown
Due 29 April 1997
Resolved 29 April 1997
Engineering
Issued 29 April 1997
Resolved
PROVE PROPER OPERATION OF REMOTE FUEL SHUT-OFFS. TO BE COMPLETED PRIOR TO THE CARRIAGE OF PASSENGERS.
Condition: Unknown
Due 29 April 1997
Resolved 29 April 1997
Construction/Loadline
Issued 29 April 1997
Resolved
INSTALL CHECK VALVES IN BILGE SUCTION LINES.
Condition: Unknown
Due 29 April 1997
Resolved 29 April 1997
Lifesaving
Issued 29 April 1997
Resolved
POST APPROPRIATE LIFE JACKET DONNING PLACARDS.
Condition: Unknown
Due 29 April 1997
Resolved 29 April 1997
Lifesaving
Issued 29 April 1997
Resolved
PROVIDE PROOF OF NOAA EPIRB REGISTRATION.
Condition: Unknown
Due 29 April 1997
Resolved 29 April 1997
Electrical
Issued 29 April 1997
Resolved
REMOVE OR PROPERLY CONNECT DEAD-END WIRES IN WAY OF STBD AFT DECK WASH PUMP. PROPERLY SEAL DECK PENETRATION DIRECTLY ABOVE STBD BATTERY BOX (AFT ENG COMPARTMENT).
Condition: Unknown
Due 29 April 1997
Resolved 29 April 1997
Construction/Loadline
Issued 29 April 1997
Resolved
INVESTIGATE AND DETERMINE EXTENT OF WATER PENETRATION/DAMAGE TO STBD DECK ADJACENT TO ENGINE COMPARTMENT ACCESS COVER. PRIOR TO MAKING REPAIRS, MAKEAVAILABLE FOR USCG INSPECTION AND PRESENT REPAIR PROPOSAL.
Condition: Unknown
Due 29 April 1997
Resolved 29 April 1997
Construction/Loadline
Issued 29 April 1997
Resolved
INVESTIGATE AND DETERMINE EXTENT OF DAMAGE IN WAY OF DELAMINATED/HOLED FIBERGLASS (UNDERDECK - LEAKING WATER) SIX FEET AFT OF DECKHOUSE ON PORT SIDE. PRIOR TO MAKING REPAIRS, MAKE AVAILABLE FOR USCG INSPECTION AND SUBMIT REPAIR PROPOSAL.
Condition: Unknown
Due 29 April 1997
Resolved 29 April 1997
Documentation
Issued 29 April 1997
Resolved
PROVIDE UPDATED FCC STATION LICENSE FOR VESSEL.
Condition: Unknown
Due 29 April 1997
Resolved 29 April 1997
Fire Fighting
Issued 22 February 1996
Resolved
PERFORM HYDROSTATIC TEST ON TWO PORTABLE CO2 EXTINGUISHERS, WHICH WERE FOUND TO BE OUT OF DATE, TO THE SATISFACTION OF THE COGNIZANT OFFICER IN CHARGE MARINE INSPECTION.
Condition: Unknown
Due 22 February 1996
Resolved 22 February 1996
Construction/Loadline
Issued 22 February 1996
Resolved
CONDUCT OPERATIONAL TEST OF BILGE PUMP/PIPING SYSTEM TO THE SATISFACTION OFTHE COGNIZANT OFFICER IN CHARGE MARINE INSPECTION.
Condition: Unknown
Due 22 February 1996
Resolved 22 February 1996
Lifesaving
Issued 22 February 1996
Resolved
REPLACE DETERIORATED RING BUOY LIFELINE TO THE SATISFACTION OF THE COGNIZANT OFFICER IN CHARGE MARINE INSPECTION PRIOR TO PLACING THE VESSEL BACK IN SERVICE.
Condition: Unknown
Due 22 February 1996
Resolved 22 February 1996
Lifesaving
Issued 22 February 1996
Resolved
TEST THE EMERGENCY POSITION INDICATING RADIO BEACON TO THE SATISFACTION OF THE COGNIZANT OFFICER IN CHARGE MARINE INSPECTION PRIOR TO PLACING THE VSL BACK IN SERVICE.
Condition: Unknown
Due 22 February 1996
Resolved 22 February 1996
Navigation
Issued 22 February 1996
Resolved
CONDUCT OPERATIONAL TEST OF THE UHF RADIO TO THE SATISFACTION OF THE COGNIZANT OFFICER IN CHARGE MARINE INSPECTION PRIOR TO PLACING THE VESSEL BACK IN SERVICE.
Condition: Unknown
Due 22 February 1996
Resolved 22 February 1996
Engineering
Issued 22 February 1996
Resolved
PROVE PROPER OPERATION OF THE INOPERABLE PORT AND BOW (FWD) FUEL TANK EMERGENCY CLOSURE DEVICES TO THE SATISFACTION OF THE OFFICER IN CHARGE MARINE INSPECTION.
Condition: Unknown
Due 22 February 1996
Resolved 22 February 1996
Engineering
Issued 22 February 1996
Resolved
REPLACE THE DETERIORATED ENGINE FUEL OIL HOSE TO THE SATISFACTION OF THE COGNIZANT OFFICER IN CHARGE MARINE INSPECTION PRIOR TO OPERATING THE MAIN ENGINE.
Condition: Unknown
Due 22 February 1996
Resolved 22 February 1996
Construction/Loadline
Issued 22 February 1996
Resolved
MAKE PERMANENT REPAIRS TO FACTURES FOUND IN THE PORT AND STBD HULL AREAS. REPAIRS SHALL BE MADE TO THE SATISFACTION OF THE COGNIZANT OFFICER IN CHARGE MARINE INSPECTION PRIOR TO PLACING THE VESSEL BACK IN THE WATER.
Condition: Unknown
Due 22 February 1996
Resolved 22 February 1996
Engineering
Issued 22 February 1996
Resolved
CONDUCT OPERATIONAL TEST OF MAIN ENGINE TO THE SATISFACTION OF COGNIZANT OFFICER IN CHARGE MARINE INSPECTION.
Condition: Unknown
Due 22 February 1996
Resolved 22 February 1996
Engineering
Issued 22 February 1996
Resolved
PROPERLY INSTALL FLAME SCREENS ON FUEL TANK VENTS TO THE SATISFACTION OF THE COGNIZANT OFFICER IN CHARGE MARINE INSPECTION.
Condition: Unknown
Due 22 February 1996
Resolved 22 February 1996
Construction/Loadline
Issued 22 February 1996
Resolved
MAKE PERMANENT REPAIR TO CONTACT DAMAGE IN THE STEM. REPAIR SHALL BE MADE TO THE SATISFACTION OF THE COGNIZANT OFFICER IN CHARGE MARINE INSPECTION PRIOR TO PLACING THE VESSEL BACK IN THE WATER.
Condition: Unknown
Due 22 February 1996
Resolved 22 February 1996
Construction/Loadline
Issued 22 February 1996
Resolved
MAKE PERMANENT REPAIR TO FRACTURE FOUND IN THE LAZARETTE UNDERDECK AREA JUST STBD AND FWD OF THE ACCESS OPENING. FRACTURE IS APPROX. 8" LONG AND RUNS IN A FORE AND AFT DIRECTION. REPAIR SHALL BE MADE TO THE SATISFACTIONOF THE COGNIZANT [name withheld] THE VESSEL BACK IN THE WATER.
Condition: Unknown
Due 22 February 1996
Resolved 22 February 1996
Construction/Loadline
Issued 22 February 1996
Resolved
MAKE PERMANENT REPAIR TO FRACTURE FOUND IN THE STBD QUARTER WHERE THE SIDESHELL AND THE TRANSOM MEET ON THE OUTBOARD SIDE. REPAIR SHALL BE MADE TO THE SATISFACTION OF THE COGNIZANT OFFICER IN CHARGE MARINE INSPECTION PRIOR TO PLACING THE VESSEL BACK IN THE WATER.
Condition: Unknown
Due 22 February 1996
Resolved 22 February 1996
Construction/Loadline
Issued 22 February 1996
Resolved
MAKE PERMANENT REPAIR TO FRACTURE FOUND IN THE PORT QUARTER WHERE THE SIDESHELL AND TRANSOM MEET ON THE INBOARD SIDE. REPAIR SHALL BE MADE TO THESATISFACTION OF THE COGNIZANT OFFICER IN CHARGE MARINE INSPECTION PRIOR TO PLACING THE VESSEL BACK IN THE WATER.
Condition: Unknown
Due 22 February 1996
Resolved 22 February 1996
Deck/Cargo
Issued 22 February 1996
Resolved
REPLACE THE DETERIORATED AND LEAKING ENGINE DRIVEN DECK WASHDOWN HOSE TO THE SATISFACTION OF THE COGNIZANT OFFICER IN CHARGE MARINE INSPECTION.
Condition: Unknown
Due 22 February 1996
Resolved 22 February 1996
Construction/Loadline
Issued 20 April 1995
Resolved
PROVIDE SCUPPERS FOR ALL EXISTING FREEING PORTS CURRENTLY IN THE VESSEL.
Condition: Unknown
Due 20 April 1995
Resolved 20 April 1995
Documentation
Issued 18 March 1994
Resolved
POST OIL POLLUTION PREVENTION PLACARD.
Condition: Unknown
Due 18 March 1994
Resolved 18 March 1994
Lifesaving
Issued 18 March 1994
Resolved
OBTAIN TWO USCG APPROVED ADULT PFD'S. PASSENGERS AND CREW LIMITED TO 20 UNTIL COMPLIANCE.
Condition: Unknown
Due 18 March 1994
Resolved 18 March 1994
Navigation
Issued 18 March 1994
Resolved
OBTAIN THE FOLLOWING NAVIGATION PUBLICATIONS AND CHARTS: CHART TO TILLAMOOKBAY ENTRANCE, US COAST PILOT, LIGHT LIST, NAVIGATION RULES OF THE ROAD(COLREGS), AND SUBCHAPTER T (46 CFR PARTS 166-199).
Condition: Unknown
Due 18 March 1994
Resolved 18 March 1994
Engineering
Issued 18 March 1994
Resolved
LABEL EMERGENCY FUEL SHUT-OFF VALVE.
Condition: Unknown
Due 18 March 1994
Resolved 18 March 1994
Construction/Loadline
Issued 18 March 1994
Resolved
LABEL STERN WITH NAME AND HOMEPORT.
Condition: Unknown
Due 18 March 1994
Resolved 18 March 1994
Engineering
Issued 18 March 1994
Resolved
CONDUCT OPERATIONAL TEST OF PROPULSION MACHINERY IN PRESENCE OF USCG MARINEINSPECTOR.
Condition: Unknown
Due 18 March 1994
Resolved 18 March 1994
Engineering
Issued 18 March 1994
Resolved
CONDUCT OPERATIONAL TEST OF ENGINE CONTROLS IN PRESENCE OF USCG MARINE INSPECTOR.
Condition: Unknown
Due 18 March 1994
Resolved 18 March 1994
Construction/Loadline
Issued 18 March 1994
Resolved
CONDUCT OPERATIONAL TEST OF BILGE PUMP AND PIPING SYSTEM IN PRESENCE OF USCG MARINE INSPECTOR.
Condition: Unknown
Due 18 March 1994
Resolved 18 March 1994
Engineering
Issued 18 March 1994
Resolved
RENEW FUEL TANK FILL HOSE LINES, PORT AND STBD, WITH USCG ACCEPTED A1, A2, B1, OR B2 HOSE.
Condition: Unknown
Due 18 March 1994
Resolved 18 March 1994
Navigation
Issued 19 March 1992
Resolved
PROVIDE A COMPASS DIVIATION TABLE.
Condition: Unknown
Due 19 March 1992
Resolved 19 March 1992
Construction/Loadline
Issued 19 March 1992
Resolved
MAKE ENGINEROOM HATCH WATERTIGHT IN WAY OF THE FWD AND AFT VERTICAL SEAMS.
Condition: Unknown
Due 19 March 1992
Resolved 19 March 1992
Engineering
Issued 9 October 1990
Resolved
REPLACE RUBBER SHAFT SEAL.
Condition: Unknown
Due 9 October 1990
Resolved 9 October 1990
Construction/Loadline
Issued 9 March 1989
Resolved
ADD AN ADDITIONAL 21 SQUARE INCHES OF FREEING PORT AREA.
Condition: Unknown
Due 9 March 1989
Resolved 9 March 1989
Lifesaving
Issued 9 March 1989
Resolved
LABEL BUOYANT APPARATUS WITH CAPACITY AND VESSEL NAME IN ACCORDANCE WITH 46CFR185.30-5.
Condition: Unknown
Due 9 March 1989
Resolved 9 March 1989
Lifesaving
Issued 5 March 1987
Resolved
PRIOR TO CARRYING PASSENGERS FOR HIRE, PROVIDE A WEAK LINK FOR THE BUOYANT APPARATUS SEA PAINTER.
Condition: Unknown
Due 5 March 1987
Resolved 5 March 1987
Navigation
Issued 5 March 1987
Resolved
PRIOR TO CARRYING PASSENGERS FOR HIRE, REPAIR THE ANCHOR LIGHT.
Condition: Unknown
Due 5 March 1987
Resolved 5 March 1987
Lifesaving
Issued 5 March 1987
Resolved
PRIOR TO CARRYING PASSENGERS FOR HIRE, PROVIDE MOUNTING BRACKETS FOR THE RING LIFE BUOY AND BUOYANT APPARATUS WATER LIGHTS ON THE EXTERIOR OF THE SUPERSTRUCTURE AND ATTATCH THE WATER LIGHTS TO THE RING LIFE BUOY AND THE BUOYANT APPARATUS.
Condition: Unknown
Due 5 March 1987
Resolved 5 March 1987
Lifesaving
Issued 5 March 1987
Resolved
VESSEL IS LIMITED TO CARRIAGE OF TWO CHILDREN UNTIL AN ADDITIONAL CHILD PERSONAL FLOATING DEVICE IS PROVIDED. FOR CERTIFICATE OF INSPECTION COMPLIANCE A TOTAL OF THREE CHILD PFD'S ARE REQUIRED.
Condition: Unknown
Due 5 March 1987
Resolved 5 March 1987
Lifesaving
Issued 5 March 1987
Resolved
PRIOR TO CARRYING PASSENGERS FOR HIRE, REPLACE THE SEVEN ADULT AND TWO CHILD PERSONAL FLOTATION DEVICES (LIFE JACKETS) THAT WERE REJECTED.
Condition: Unknown
Due 5 March 1987
Resolved 5 March 1987