Records from 1985 to 1992. Most recent: inspection, 9 November 1992.
A report is not offered for this hull: Its record holds only 2 of the seven kinds of material a report is built from: inspections, deficiencies, operational controls, tow-unit appearances, casualty records, dimensions and documentation. That is a statement about the record, not about the vessel. Reports.
Inspection history · 25
9 November 1992
Administrative
Administrative · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 950997
12 July 1992
Type not recorded
No type recorded · MSO GUAM · USCG Oceania District (CGD-O) · Activity 665672
16 June 1992
COI Inspection
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1258729
9 March 1992
Type not recorded
No type recorded · MSO GUAM · USCG Oceania District (CGD-O) · Activity 647508
24 January 1992
Type not recorded
No type recorded · MSO GUAM · USCG Oceania District (CGD-O) · Activity 30477
24 January 1992
Type not recorded
No type recorded · MSO GUAM · USCG Oceania District (CGD-O) · Activity 41698
3 January 1992
Type not recorded
No type recorded · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 949212
26 September 1991
Type not recorded
No type recorded · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 934349
13 August 1991
Deficiency Check
Physical examination · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 933252
6 June 1991
Administrative
Administrative · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 928112
4 June 1991
Administrative
Administrative · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1237572
20 May 1991
Re-Inspection
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1228911
20 May 1991
Deficiency Check
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1229475
9 April 1991
Type not recorded
No type recorded · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 465302
16 April 1990
Hull Examination · COI Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1221574
3 October 1989
Re-Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1203161
13 May 1989
Deficiency Check
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 897331
30 September 1988
COI Inspection
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1193863
8 October 1987
Re-Inspection
Physical examination · MIO HOUSTON · USCG Heartland District (CGD-H) · Activity 1324163
18 September 1987
Administrative
Administrative · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1010540
14 August 1987
Type not recorded
No type recorded · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1033351
13 May 1987
Drydock Extension
Administrative · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1309969
8 October 1986
COI Inspection
Physical examination · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1321741
24 September 1985
Re-Inspection
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1299015
19 September 1985
Type not recorded
No type recorded · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1300047
Navigation
Issued 16 June 1992
Resolved
PROVE PROPER OPERATION OF STEERING GEAR INDICATOR PANEL IN PILOT HOUSE.
Condition: Unknown
Due 16 June 1992
Resolved 16 June 1992
Accommodation/Occupational Safety
Issued 16 June 1992
Resolved
PROVIDE DIAL KNOB FOR SOUND POWERED PHONE IN ENGINE ROOM.
Condition: Unknown
Due 16 June 1992
Resolved 16 June 1992
Engineering
Issued 16 June 1992
Resolved
PROVIDE COAST GUARD APPROVED AUTOMATION TEST PROCEDURE. INCREASE MANNING LEVEL BY TWO ASST ENGINEERS AND THREE OILERS FOR VOYAGES OF 600 MILES AND MORE OR ONE ASST ENGINEER AND TWO OILERS FOR VOYAGES LESS THAN 600 MILES UNTIL AN COAST GUARD APPROVED MAIN PROPULSION AUTO. PROCEDURES ARE VERIFIED
Condition: Unknown
Due 16 June 1993
Resolved 18 May 2002
Resolution: MISLE Maintenance - Resolved all open deficiencies issued prior to 6/1/1997 where activity was closed and deficiency due date was past
Documentation
Issued 26 September 1991
Resolved
ALL VESSEL SYSTEMS, REGULATORY AND PROPRIETARY VESSEL DOCUMENTS, AND VESSELOPERATIONS MUST BE BROUGHT INTO FULL COMPLIANCE WITH SUBCHAPTERS "I", "F", "J" OF TITLE 46, CODE OF FEDERAL REGULATIONS TO THE SATISFACTION OF THE COGNIZANT OFFICER IN CHARGE, MARINE INSPECTION. SEE SFCMS LTR DTD 25OCT91.
Condition: Unknown
Due 26 September 1991
Resolved 26 September 1991
Documentation
Issued 20 May 1991
Resolved
PROVIDE WASTE MANAGEMENT PLAN.
Condition: Unknown
Due 20 May 1991
Resolved 20 May 1991
Lifesaving
Issued 20 May 1991
Resolved
PROVIDE 8 ADDITIONAL IMMERSION SUITS; UNLESS COI CHANGED. UNTIL THIS ITEM IS COMPLIED WITH, THE VESSEL IS RESTRICTED TO CARRYING LESS THAN 12 PERSONS.
Condition: Unknown
Due 20 May 1991
Resolved 20 May 1991
Lifesaving
Issued 20 May 1991
Resolved
PROVIDE 6 ADDITIONAL LIFEJACKETS WITH LIGHTS AND WHISTLES. UNTIL THIS ITEMIS COMPLIED WITH, THE VESSEL IS RESTRICTED TO CARRYING LESS THAN 14 PERSONS.
Condition: Unknown
Due 20 May 1991
Resolved 20 May 1991
Navigation
Issued 20 May 1991
Resolved
SHOW PROPER OPERATION OF FATHOMETER.
Condition: Unknown
Due 30 September 1991
Resolved 18 May 2002
Resolution: MISLE Maintenance - Resolved all open deficiencies issued prior to 6/1/1997 where activity was closed and deficiency due date was past
Deck/Cargo
Issued 20 May 1991
Resolved
SHOW PROPER OPERATION OF STARBOARD ANCHOR.
Condition: Unknown
Due 16 April 1993
Resolved 18 May 2002
Resolution: MISLE Maintenance - Resolved all open deficiencies issued prior to 6/1/1997 where activity was closed and deficiency due date was past
Accommodation/Occupational Safety
Issued 20 May 1991
Resolved
REPLACE SCREEN IN FORE HEAD VENT.
Condition: Unknown
Due 20 May 1991
Resolved 20 May 1991
Documentation
Issued 20 May 1991
Resolved
PROVE INTENT TO COMPLY WITH DRUG TESTING REQUIREMENTS OF 46 CFR 4.06 AND 16.
Condition: Unknown
Due 20 May 1991
Resolved 20 May 1991
Engineering
Issued 20 May 1991
Resolved
PROVIDE PROPER FLAME IMPINGEMENT SCREENS FOR RACOR FILTERS.
Condition: Unknown
Due 20 May 1991
Resolved 20 May 1991
Fire Fighting
Issued 20 May 1991
Resolved
PROVIDE ONE ADDITIONAL SCBA FOR FIRE FIGHTING OUTFIT. VESSEL IS NOT TO SAIL UNTIL THIS ITEM IS IN COMPLIANCE.
Condition: Unknown
Due 20 May 1991
Resolved 20 May 1991
Fire Fighting
Issued 20 May 1991
Resolved
PROVIDE TWO FLAME SAFETY LAMPS OR TWO 02/COMBUSTIBLE INDICATORS. VESSEL ISNOT TO SAIL UNTIL THIS ITEM IS IN COMPLIANCE.
Condition: Unknown
Due 20 May 1991
Resolved 20 May 1991
Lifesaving
Issued 20 May 1991
Resolved
PROVIDE RING BUOYS WITH RETROREFLECTIVE TAPE.
Condition: Unknown
Due 20 May 1991
Resolved 20 May 1991
Construction/Loadline
Issued 20 May 1991
Resolved
INSTALL WEATHERTIGHT ENCLOSURE PORT BRIDGE WING. THIS ITEM TO BE CORRECTED PRIOR TO LEAVING PROTECTED WATERS.
Condition: Unknown
Due 20 May 1991
Resolved 20 May 1991
Unknown
Issued 3 October 1989
Resolved
REMOVE DEAD END WIRING PORT MAIN DECK LOCKER, MARK ALL SWITCHES DISCONNECTSWITH SYSTEM SERVED, REPLACE BROKEN HANGERS ON OVERHEAD WIRING.
Condition: Unknown
Due 3 October 1989
Resolved 3 October 1989
Unknown
Issued 3 October 1989
Resolved
ADD GUARD TO JANITARY PUMP LOCATED IN THRUSTER ENGINE ROOM, REPLACE PACKINGIN PUMP.
Condition: Unknown
Due 3 October 1989
Resolved 3 October 1989
Unknown
Issued 3 October 1989
Resolved
REMOVE STOWED GEAR FROM ALL STATEROOMS, NOT PART OF CREW'S PERSONAL GEAR.
Condition: Unknown
Due 3 October 1989
Resolved 3 October 1989
Unknown
Issued 3 October 1989
Resolved
INSTALL NEW GAUGE FOR WORKING AIR ON BRIDGE CONCOLE GAUGE ONLY READS 150 LBS/IN2, ACTUAL PRESS. APPROX 190 LBS/IN2.
Condition: Unknown
Due 3 October 1989
Resolved 3 October 1989
Unknown
Issued 3 October 1989
Resolved
ADD DRIP SHIELDS TO TRANSFORMERS LOCATED ON BRIDGE DECK STBD SIDE.
Condition: Unknown
Due 3 October 1989
Resolved 3 October 1989
Unknown
Issued 3 October 1989
Resolved
RE-MOUNT LOOSE JUNCTION BOX HANGING BY WIRE BENEATH STEERING CONSOLE ON BRIDGE.
Condition: Unknown
Due 3 October 1989
Resolved 3 October 1989
Unknown
Issued 3 October 1989
Resolved
REPAIR LEAK IN MARINE SANITATION DEVICE (MSD).
Condition: Unknown
Due 3 October 1989
Resolved 3 October 1989
Deck/Cargo
Issued 30 September 1988
Resolved
INSTALL PRESSURE RELIEF DEVICES ON ALL FOUR (04) DRY BULK TANKS (P-TANKS) AS PER 46CFR54.15.
Condition: Unknown
Due 30 September 1988
Resolved 30 September 1988
Lifesaving
Issued 30 September 1988
Resolved
PROVIDE TEN (10) SERVICE PROJECTILES FOR THE REQUIRED SHOULDER GUN TYPE LINE-THROWING APPARATUS AS PER 46CFR94.45-15(B)(1).
Condition: Unknown
Due 30 September 1988
Resolved 30 September 1988
Construction/Loadline
Issued 30 September 1988
Resolved
REMOVE FROM VESSEL ALL FLAMMABLE LIQUIDS AND PAINTS STOWED IN STARBOARD SIDE DECK LOCKER OR INSTALL, FOR STOWAGE OF SUCH MATERIAL, PAINT LOCKER AS PER 46CFR PARTS 92.05-10, 95.05-10(C) AND (G).
Condition: Unknown
Due 30 September 1988
Resolved 30 September 1988
Fire Fighting
Issued 30 September 1988
Resolved
PROVIDE COMBINATION SOLID STREAM AND WATER SPRAY FIRE HOSE NOZZLE AT MAIN DECK FIRE HOSE STATION PORT SIDE OF CARGO DECK AS PER 46CFR95.10-10(I).
Condition: Unknown
Due 30 September 1988
Resolved 30 September 1988
Fire Fighting
Issued 30 September 1988
Resolved
PROVIDE LOW-VELOCITY WATER SPRAY APPLICATOR AT ENGINE ROOM FIRE HOSE STATION AS PER 46CFR95.10-10(I)(I-1).
Condition: Unknown
Due 30 September 1988
Resolved 30 September 1988
Construction/Loadline
Issued 13 May 1987
Resolved
MAKE PERMANENT REPAIR TO HOLED LONGITUDINAL BULKHEAD WHICH SEPARATES #5 AND #6 STBD BALLAST TANKS.
Condition: Unknown
Due 13 May 1987
Resolved 13 May 1987
Construction/Loadline
Issued 13 May 1987
Resolved
MAKE DRAFT MARKS AND LOAD LINE MARKS LEGIBLE IN CONTRASTING COLOR TO HULL.
Condition: Unknown
Due 13 May 1987
Resolved 13 May 1987