← All vessels
JADE I
Freight Ship · Bulk Carrier class · Built 1990s · USCG Southwest District (CGD-SW) · Other hulls named JADE I
JADE I is a 1998 freight ship. The Coast Guard has recorded 33 inspections since 1998, most recently in January 2016, along with 25 deficiencies and 7 operational controls.
Records from 1998 to 2016. Most recent: operational control imposed, 27 January 2016.
- Built
- 1998
- Last inspected
- 26 January 2016
- Documentation
- Not in the documentation file of 10 September 2026
- Deficiencies
- 25 recorded · 0 without a recorded resolution
- Controls
- None recorded without a removal date
Identity
9162411 View on MarineTraffic leaves Maury; a third-party site, nothing from it is stored here
3FZW
480614
Flag
PANAMA
—
Maury page id
psix-480614
Inspections, by type
…with no type recorded13
Years with a record
16 calendar years (1998–2016)
The 33 inspections in the strip above, split by the kind of activity the US
Coast Guard recorded. Years with a record are calendar years in which a record exists, not
years in service. What Maury does not do.
This record may be incomplete: the most recent inspection recorded for this vessel was 10 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Bulk Carrier class in Maury's sources begin in 1981.
Documentation record
Tonnage as PSIX records it15660 - Convention (Subpart B), Gross Ton
8745 - Convention (Subpart B), Net Ton
25012 - Dead Weight, Ton
30816 - Displacement, Ton
8745 - Convention (Subpart B), Net Ton
25012 - Dead Weight, Ton
30816 - Displacement, Ton
This hull's Official Number is not in the NVDC file dated 10 September 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.
Radio station licence
No FCC ship-station licence is recorded against this Official Number in the file of
6 September 2026. That is a fact about the licence file, not about the radio.
Inspection history · 33
26 January 2016
ISPS III Exam · Ballast Water Examination · PII Safety Exam
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 5803801
16 August 2015
Type not recorded
No type recorded · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 5218355
27 August 2014
ISPS II Exam · Ballast Water Examination · PII Safety Exam
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 4958809
21 March 2014
Administrative Inspection
Administrative · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 4820588
19 January 2011
MARPOL Annex V Examination · MARPOL Annex I Examination
Physical examination · Sector Columbia River · USCG Northwest District (CGD-NW) · Activity 3929281
24 September 2010
PII Safety Exam · ISPS II Exam
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 3855754
29 March 2010
COE-Administrative
Administrative · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 3705137
26 March 2010
COE-Dockside
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 3699261
26 February 2010
COE-Administrative
Administrative · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 3686841
12 February 2010
COE-Administrative
Administrative · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 3679428
7 February 2010
COE-Dockside
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 3673756
20 November 2008
Deficiency Check
Physical examination · Sector Portland · USCG Northwest District (CGD-NW) · Activity 3366684
21 August 2008
Ballast Water Examination · ISPS II Exam · MARPOL Annex I Examination · MARPOL Annex V Examination · PII Safety Exam
Physical examination · Sector Portland · USCG Northwest District (CGD-NW) · Activity 3304799
26 July 2007
Ballast Water Examination · MARPOL Annex V Examination · ISPS II Exam · MARPOL Annex I Examination · PII Safety Exam
Physical examination · Sector Portland · USCG Northwest District (CGD-NW) · Activity 2994444
19 July 2007
Type not recorded
No type recorded · Sector Portland · USCG Northwest District (CGD-NW) · Activity 3001562
16 July 2007
Type not recorded
No type recorded · Sector Portland · USCG Northwest District (CGD-NW) · Activity 2997506
18 June 2006
MARPOL Annex I Examination · ISPS II Exam · Ballast Water Examination · PII Safety Exam
Physical examination · Sector Portland · USCG Northwest District (CGD-NW) · Activity 2683268
16 June 2005
MARPOL Annex I Examination · Random ISPS/MTSA/PSC · Ballast Water Examination
Physical examination · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 2392526
13 June 2005
Type not recorded
No type recorded · Sector Astoria · USCG Northwest District (CGD-NW) · Activity 2389630
6 April 2005
Random ISPS/MTSA/PSC
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 2327999
11 January 2005
ISPS II Exam · NPV Safety Exam · MARPOL Annex I Examination · Ballast Water Examination
Physical examination · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 2270265
6 January 2005
Type not recorded
No type recorded · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 2273625
15 June 2004
MTSA/ISPS Verification · Re-Inspection · Ballast Water Examination
Physical examination · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 2091560
9 June 2004
Type not recorded
No type recorded · Sector Astoria · USCG Northwest District (CGD-NW) · Activity 2094961
14 November 2003
Ballast Water Examination · Annual Inspection · MARPOL Annex I Examination
Physical examination · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 1945265
24 October 2002
Annual Inspection
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1691727
25 February 2002
Type not recorded
No type recorded · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1600539
23 November 2001
Type not recorded
No type recorded · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 295756
5 August 2001
Type not recorded
No type recorded · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 292381
14 May 2000
Type not recorded
No type recorded · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 277676
26 October 1999
Type not recorded
No type recorded · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 433886
4 April 1999
Type not recorded
No type recorded · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 428281
12 November 1998
Type not recorded
No type recorded · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 422604
Deficiency record · 25
Operations/Management › Drills/Instruction › Fire
Issued 27 January 2016
Resolved
0925: Master and crew shall be familiar with essential shipboard procedures relating to the safety of the ship. Crewmembers failed two consecutive fire drills. During the first fire drill sex crewmembers were not wearing the proper personal protective equipment while transiting through a passageway where the fire was located. /// Deficiency continued in Activity #5803801 Narrative
Operations/Management › Vessel Safety Management › Company Responsibilities/Authority
Issued 27 January 2016
Resolved
2510: The Company should establish procedures to ensure that all personnel involved in the company’s safety management system have an adequate understanding of relevant rules, regulations, codes and guidelines. Objective evidence exist that the vessel is not implementing the safety management system.
Documentation › Logs/Records › Ballast Water Logs/Records
Issued 27 January 2016
Resolved
2510: Vessel must maintain a Ballast Water Management Plan that has been developed specifically for the vessel that will allow those responsible for the plan to understand and follow it. Vessel has a Ballast Water Management Plan but not all of the sections are being followed. Proper forms are not being filled out. Deficiency continued in Activity #5803801
Documentation › Logs/Records › Oil Record Book
Issued 27 January 2016
Resolved
1710: Every ship 400 gross tons and above shall be provided with an Oil Record Book. Dates for operations are missing starting in July 2015. MARPOL AX.I/Reg.17 (17ac)
Documentation › Manuals/Policy Documentation › Transfer Procedures
Issued 27 January 2016
Resolved
2535: Company should establish procedures, instructions, including checklist as appropriate for key shipboard operations concerning the safety of personnel, ship and environment. Vessel has change over procedures for HFO-LSFO and MGO; however the Chief Engineer has re-written the companies procedures to fit his interpretation of those procedures. MARPOL AX.VI/14.6 (17ac)
Documentation › Logs/Records › Garbage Recordkeeping
Issued 27 January 2016
Resolved
2120: Every ship of 400GT and above shall be provided with a Garbage Record Book and shall be in the form specified in the appendix to this Annex. Garbage Record Book has incorrect entries for discharge to reception facilities in format, date and Master signature. In addition mixed plastic found in final collection area of vessel. MARPOL AX.V/9.3 (17ac)
Fire Fighting › Miscellaneous Items › A Class Division Penetrations
Issued 27 January 2016
Resolved
0750: Where “A” class division are penetrated such penetrations shall be tested in accordance with the Fire Test Procedures Code. “A” division penetrations found without insulation at “D” deck stairway “C” deck cable trunk and upper deck engine. 74SOLAS(04)II-2/9.3.1 (17ac)
Electrical › Electric Supply System (service) › Cable
Issued 27 January 2016
Resolved
0950: All electrical apparatus shall be so constructed and so installed as not to cause injury. SCBA air compressor installed to emergency generator switchboard, washing machine installed at “D” deck wash closet to the light switch. Vessel was unable to provide approval for these installations. 74SOLAS(14)II-1/45.1.3 (17ac)
Engineering › Pressure Vessel › Piping
Issued 27 January 2016
Resolved
1400: The machinery and other pressure vessel and associated piping and fittings shall be design and construction adequate for the service for which they are intended. Fresh Water Generator has three patched on it and the main engine air start valve has a block of wood holding it in place. 74SOLAS(14)II-1/26 (17ac)
Pollution Prevention/Response › Prevention Equipment › Sewage System Tank
Issued 27 January 2016
Resolved
2510: Sewage system must be operated and maintained in accordance with the manufacture’s instructions. Sewage plant has six patches on top. Tablets are incorrect sixe and crew has not carried out maintenance as required. Raw sewage may be going directly overboard. 33CFR159.121(b) (17ac)
Operations/Management › Vessel Safety Management › Plans for Shipboard Operations
Issued 27 January 2016
Resolved
[withheld — contains personal information; the deficiency system, dates, and resolution status are shown above]
Fire Fighting › Firemans Outfit › Protective Clothing
Issued 27 January 2016
Resolved
0720: Fire fighting system and appliances shall be kept in good working order. Vessel has one set of fireman’s outfit pants wasted and not fit for service. A request for replacement made May 2015 by vessel. 74SOLAS(14)II-2/14.2.1.2 (17ac)
Operations/Management › Vessel Safety Management › External Certification/Verification/Control
Issued 26 January 2016
Resolved
2535: Due to the above objective evidence the Captain of the Port questions the adequacy of the implementation of the vessel’s Safety Management System under the International Safety Management (ISM) Code. An external audit is recommended to be conducted within 30 days b the Flag State or Recognized Organization to determine whether the ship is operating in accordance with the ISM Code. (40ac)
Fire Fighting › Fixed Fire Detection System › Heat Detectors
Issued 27 August 2014
Resolved
0715 - DETECTION - THE FUNTION OF THE FIRE DETECTION SYSTEM SHALL BE PERIODICALLY TESTED TO THE SATISFACTION OF THE ADMINISTRATION BY MEANS OF EQUIPMENT PRODUCING HOT AIR AT THE APPROPRIATE TEMPERATURE...CONTINUED IN NARATIVE OF ACTIVITY#4958809 - SOLAS 74 (1997 CONS.) II-2/13.1.13 40 (C)
Fire Fighting › Structural - A Class Divisions › Machinery Spaces
Issued 27 August 2014
Resolved
0710 - Fire Protection - Doors fitted in boundary bulkheads of machinery spaces of category "A" shall be reasonably gastight and self closing. An "A" class fire door on the portside upper deck leading into the aft machinery flat above the steering room has an approx 2in. gap between the bottom of the door and the deckplate,making it unable to be gastight - SOLAS 74 (1997 CONS.) II-2/47.1 40(c)
Pollution Prevention/Response › Prevention Equipment › Incinerator, Shipboard
Issued 19 January 2011
Resolved
The condition of the ship and it's equipment shall be maintained to conform with the provisions of the present Convention. The incinerator required by the IOPP Supplement for the disposal of oily residues must be inoperational condition. The incinerator is unable to be started. 17AC
Fire Fighting › Structural - A Class Divisions › Fire Doors
Issued 21 August 2008
Resolved
On main deck port side, Class "A" fire door leading to engine room is not reasonably gas-tight negating fire integrity of bulkhead/boundary.
BREAK: 17OCT08 repairs have not been made to fire door. Amended Form B from 17ac to 70ac based on class report.
Navigation › Piloting/Steering › Gyro Compass
Issued 25 February 2002
Resolved
Gyrocompass inoperable.
Lifesaving
Issued 26 October 1999
Resolved
Make stbd davit ready for immediate use where lifeboat was stuck. SOLAS 74amd III/19.2. Correct prior to depature.
Fire Fighting
Issued 26 October 1999
Resolved
Provide operating instructions for the fixed CO2 system in the language of the crew (chinese) SOLAS 74 amd II-2/20. Correct prior to next U.S. port.
Accommodation/Occupational Safety
Issued 26 October 1999
Resolved
Repair upper level port side engine room escape door to make self closing. SOLAS 74 amd I/11. Correct prior to next U.S. port.
Accommodation/Occupational Safety
Issued 26 October 1999
Resolved
Find out number to telephone in steering room and post at all other telephones prior to next U.S. port. SOLAS 74 amd I/11.
Accommodation/Occupational Safety
Issued 26 October 1999
Resolved
Stencil all escape doors leading from engine room prior to next U.S. port. SOLAS 74amd I/11.
Fire Fighting
Issued 26 October 1999
Resolved
Have semi portable foam fire extinguisher serviced. Located stbd of upper boiler flat. SOLAS 74amd II-2/21. Correct prior to depature.
Construction/Loadline
Issued 4 April 1999
Resolved
STARBOARD SIDE SHELL PLATE (FR 5-20) ON LIFE BOAT DECK DAMAGED FROM A COLLISION. CORRECT TO THE SATISFACTION OF THE VESSEL'S CLASSIFICATION SOCIETY BY 30 JUNE 1999.
Ownership record
The Coast Guard's documentation record for this hull -- the Abstract of Title,
with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National