MAURY USCG vessel records
← All vessels

HMC 504

Built
1974
Last inspected
24 July 2009
Documentation
Expired · NVDC file of 10 August 2026
Controls
None recorded without a removal date

This record may be incomplete: the most recent inspection recorded for this vessel was 17 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 23 August 2026, retrieved 5 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Barge class in Maury's sources begin in 1972.

Inspection record

Last inspected 24 July 2009
…with no type recorded35
Operational controls None recorded without a removal date
Years with a record 21 calendar years (1984–2009)
Every line above is a count of records the US Coast Guard wrote, or a date it recorded. A blank resolution means none was recorded in this data; it does not establish that a deficiency is outstanding. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Identity

Flag
UNITED STATES
Maury page id
psix-48069

Documentation record

Registered dimensions (L × B × D)147.6 ft × 54.1 ft × 9.9 ft
Registered tonnagegross 812 / net 812
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
BuilderDRAVO CORPORATION · NEVILLE ISLAND, PA, UNITED STATES · built 1974
Hull materialSteel
PropulsionUnknown
Hull shapeUNSPECIFIED
Hull configurationUNSPECIFIED
Hailing portLEMONT, IL
Endorsements, as the file codes themcw_un
DocumentationExpired · issued 30 June 2004
Service, as the file records itTank Barge
Hull formunknown (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it812 - Regulatory (Subpart C or D), Gross Ton
812 - Regulatory (Subpart C or D), Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 August 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.
Professional
The full record for this vessel

Behind this panel: 71 inspections, each with its date, unit and type; 26 deficiencies with the resolution recorded against each; operational controls, none recorded without a removal date; 1 other vessel inspected with it; no other recorded names; the documentation record: dimensions, tonnage, builder, hailing port and endorsements. Every line is a record the Coast Guard wrote; the counts above are the same counts as in the summary, and they are free.

Professional is $39 a month or $299 a year, or $19.99 a month locked for life at the founding rate, for the first 200 subscribers. It unlocks every detail section on every vessel page, fleet watch tied to your account, and ownership records on request. Already a subscriber? Sign in.

Maury does not score, rate or grade vessels, at any price.

Vessel history report
Every record for this hull, in one document — $299

Every recorded inspection, 1972 to 2026, in one chronology · every deficiency, with system, dates and resolution · operational controls imposed and removed · every name this hull has been recorded under · the vessels it was inspected alongside, and when · how its record compares with hulls of similar age and size, as a fact about the population and never a judgement about this vessel.

Read one first, in full: a forty-year chronology · a hull that changed operators four times · the sparse case, shown as an example, not for sale.

This report is in development and is not for sale yet. There is no date, and nothing is charged. Leave an email and we will tell you when it exists, once.

Inspected as a tow unit · 1

The Coast Guard recorded this vessel and the following in the same inspection activity — normally a tug and the barges in its tow. A recreational or unclassed hull in the same activity is held and not published, so it does not appear here: these lists are a floor, not a complete manifest.

BECKY E Towing Vessel · MISLE 62978 · 2 November 1998 · activity 118769

Inspection history · 71

24 July 2009 In-Service Inspection
Physical examination · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 3544616
2 June 2005 MTSA Verification
Physical examination · MSO CHICAGO · USCG Great Lakes District (CGD-GL) · Activity 2377289
14 March 2005 Type not recorded
No type recorded · MSO CHICAGO · USCG Great Lakes District (CGD-GL) · Activity 2310035
22 December 2003 Security Plan Review - ASP
Administrative · Marine Safety Center (MSC) · Activity 1978891
22 October 2003 Re-Inspection
Physical examination · MSO CHICAGO · USCG Great Lakes District (CGD-GL) · Activity 1925576
27 September 2002 Re-Inspection
Physical examination · MSO CHICAGO · USCG Great Lakes District (CGD-GL) · Activity 1678197
26 October 2001 Administrative
Administrative · MSO CHICAGO · USCG Great Lakes District (CGD-GL) · Activity 1073955
25 October 2001 Re-Inspection
Physical examination · MSO CHICAGO · USCG Great Lakes District (CGD-GL) · Activity 1456031
25 July 2001 Re-Inspection
Physical examination · MSO CHICAGO · USCG Great Lakes District (CGD-GL) · Activity 1069727
28 July 2000 COI Inspection · Hull Examination
Physical examination · MSO CHICAGO · USCG Great Lakes District (CGD-GL) · Activity 1426454
18 February 1999 Deficiency Check
Physical examination · MSO CHICAGO · USCG Great Lakes District (CGD-GL) · Activity 1388731
14 December 1998 COI Inspection
Physical examination · MSO CHICAGO · USCG Great Lakes District (CGD-GL) · Activity 1470752
2 November 1998 Type not recorded
No type recorded · MSD PEORIA · USCG Heartland District (CGD-H) · Activity 118769
26 October 1998 Type not recorded
No type recorded · MSD PEORIA · USCG Heartland District (CGD-H) · Activity 444055
12 December 1997 Re-Inspection
Physical examination · MSO CHICAGO · USCG Great Lakes District (CGD-GL) · Activity 1442659
24 January 1997 Type not recorded
No type recorded · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 758551
9 January 1997 Type not recorded
No type recorded · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 195501
13 December 1996 Hull Examination · COI Inspection
Physical examination · MSO CHICAGO · USCG Great Lakes District (CGD-GL) · Activity 1356090
3 November 1994 Administrative
Administrative · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1174891
6 July 1994 Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 642463
28 June 1994 Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 6640
28 June 1994 Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 111478
28 June 1994 Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 117737
5 March 1994 Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 642460
5 February 1994 Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 86901
5 February 1994 Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 104665
10 December 1993 Examination of Repairs · Deficiency Check
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1382672
29 November 1993 Type not recorded
No type recorded · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 642461
3 November 1993 Permit to Proceed
Administrative · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 847539
2 November 1993 Type not recorded
No type recorded · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 90882
2 November 1993 Type not recorded
No type recorded · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 489648
8 October 1993 COI Inspection
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1419170
20 September 1993 Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 642456
1 August 1993 Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 70083
1 August 1993 Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 227893
1 February 1993 Administrative
Administrative · MSO HUNTINGTON · USCG Heartland District (CGD-H) · Activity 1136955
1 October 1992 Re-Inspection
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1248842
23 June 1992 Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 642449
14 June 1992 Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 134979
15 November 1991 Type not recorded
No type recorded · MSO CHICAGO · USCG Great Lakes District (CGD-GL) · Activity 437191
10 October 1991 COI Inspection
Physical examination · MSO HUNTINGTON · USCG Heartland District (CGD-H) · Activity 938845
10 October 1991 Administrative
Administrative · MSO HUNTINGTON · USCG Heartland District (CGD-H) · Activity 938846
8 October 1991 Type not recorded
No type recorded · MSO HUNTINGTON · USCG Heartland District (CGD-H) · Activity 503695
21 December 1990 Deficiency Check
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1229925
10 December 1990 Re-Inspection
Physical examination · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 1229011
9 July 1990 Type not recorded
No type recorded · MSO CHICAGO · USCG Great Lakes District (CGD-GL) · Activity 477893
25 April 1990 Type not recorded
No type recorded · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 531754
12 October 1989 COI Inspection
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1344902
17 May 1989 Deficiency Check
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1347365
5 March 1989 Type not recorded
No type recorded · MSO Paducah · USCG Heartland District (CGD-H) · Activity 526555
26 January 1989 Deficiency Check
Physical examination · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 1206292
26 January 1989 Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1208142
14 September 1988 Re-Inspection
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1350088
31 August 1988 Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1346548
10 June 1988 Deficiency Check
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 891082
13 April 1988 Damage Survey
Physical examination · MSO CHICAGO · USCG Great Lakes District (CGD-GL) · Activity 1340576
11 March 1988 Type not recorded
No type recorded · MSO Paducah · USCG Heartland District (CGD-H) · Activity 510825
9 October 1987 COI Inspection
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1016787
30 September 1987 Administrative
Administrative · MSO Paducah · USCG Heartland District (CGD-H) · Activity 1009597
27 September 1987 Damage Survey
Physical examination · MSO Paducah · USCG Heartland District (CGD-H) · Activity 1009596
27 August 1987 Drydock Extension
Administrative · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 1342411
25 August 1987 Administrative
Administrative · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1338914
8 June 1987 Type not recorded
No type recorded · MSO CHICAGO · USCG Great Lakes District (CGD-GL) · Activity 483424
18 May 1987 Type not recorded
No type recorded · MSO CHICAGO · USCG Great Lakes District (CGD-GL) · Activity 505301
12 May 1987 Type not recorded
No type recorded · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 478694
24 April 1987 Type not recorded
No type recorded · MSO CHICAGO · USCG Great Lakes District (CGD-GL) · Activity 459614
21 November 1986 Re-Inspection
Physical examination · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 1329395
2 October 1986 Type not recorded
No type recorded · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1313670
21 October 1985 COI Inspection
Physical examination · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1298771
3 January 1985 Type not recorded
No type recorded · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 1284289
29 January 1984 Type not recorded
No type recorded · MIO HOUSTON · USCG Heartland District (CGD-H) · Activity 971739

Deficiency record · 26

Engineering
Issued 18 February 1999 Resolved
Make repairs to vessel's thermal fluid heater exhaust duct work in way of deteriorating welded seam on the circumference of the ducting to the satis-faction of the attending marine inspector.
Condition: Unknown
Due 5 March 1999
Resolved 19 February 1999
Engineering
Issued 18 February 1999 Resolved
Make proper repairs to refractory brick on both ends of the interior of thevessel's thermal fluid heater as well as the interior overhead area at in- spection cover location. Thermal fluid heater not to be used until repairsare completed to the satisfaction of the attending marine inspector.
Condition: Unknown
Due 5 March 1999
Resolved 19 February 1999
Engineering
Issued 18 February 1999 Resolved
After completion of internal visual inspection of thermal fluid heater, make the same ready for all operational & safety tests in accordance with the manufacturers instructions to the satisfaction of the attending marine inspector.
Condition: Unknown
Due 5 March 1999
Resolved 25 February 1999
Engineering
Issued 18 February 1999 Resolved
Make vessel's thermal fluid heater available for visual inspection of in- ternal areas in way of repair work done on refractory brick, after curing time of repair work, to the satisfaction of the attending marine inspector.
Condition: Unknown
Due 5 March 1999
Resolved 25 February 1999
Documentation
Issued 14 December 1998 Resolved
PROVIDE DOCUMENTATION OF COMPLIANCE WITH AMERICAN BUREAU OF SHIPPING (ABS) ANNUAL LOAD LINE SURVEY TO THE SATISFACTION OF THE ATTENDING MARINE INSPEC-TOR AND THE COGNIZANT OCMI.
Condition: Unknown
Due 14 December 1998
Resolved 14 December 1998
Deck/Cargo
Issued 14 December 1998 Resolved
MAKE VESSEL'S THERMAL FLUID HEATING SYSTEM AVAILABLE FOR AN INTERNAL VISUALINSPECTION BY THE ATTENDING MARINE INSPECTOR AND TO THE SATISFACTION OF THEATTENDING MARINE INSPECTOR.
Condition: Unknown
Due 14 December 1998
Resolved 14 December 1998
Engineering
Issued 12 December 1997 Resolved
Prove proper operation of tachometer on prime mover prior to offloading cargo.
Condition: Unknown
Due 30 December 1997
Resolved 23 January 1998
Deck/Cargo
Issued 13 December 1996 Resolved
Make cargo tank P/V valves available for inspection.
Condition: Unknown
Due 25 February 1997
Resolved 25 February 1997
Documentation
Issued 13 December 1996 Resolved
Prior to operating provide a current ABS loadline certificate.
Condition: Unknown
Due 25 February 1997
Resolved 25 February 1997
Deck/Cargo
Issued 13 December 1996 Resolved
Prior to operating make thermal fluid heater avialable for internal inspection.
Condition: Unknown
Due 25 February 1997
Resolved 25 February 1997
Deck/Cargo
Issued 13 December 1996 Resolved
Prior to operating prove operation of the thermal fluid heater automation and safeties.
Condition: Unknown
Due 25 February 1997
Resolved 25 February 1997
Deck/Cargo
Issued 13 December 1996 Resolved
Prior to loading cargo prove operation of the pump prime mover emergency stop.
Condition: Unknown
Due 25 February 1997
Resolved 25 February 1997
Construction/Loadline
Issued 10 December 1993 Resolved
CROP AND RENEW TO GOOD METAL COLLISION BLKHD PORTSIDE IN WAY OF TEMP REPAIRPAD WELDING OF SEVERAL PINHOLES, TO BE COMPLETED DURING SCHEDULED DRYDOCK AUG94.
Condition: Unknown
Due 10 December 1993
Resolved 10 December 1993
Construction/Loadline
Issued 10 December 1993 Resolved
LOCATE AND MAKE PERMENANT REPAIRS TO LEAKING WELD BUTT UNDER 11FT DRAFT RUBPLATE STBD SIDE FWD AT DECK CORNER. OWNER REP WILL REPLACE ALL SIDE SHELL PLATING DURING SCHEDULED AUG 94 DRYDOCKING.
Condition: Unknown
Due 10 December 1993
Resolved 10 December 1993
Deck/Cargo
Issued 8 October 1993 Resolved
OPEN FOR EXAMINATION ALL THREE PV VALVES.
Condition: Unknown
Due 8 October 1993
Resolved 8 October 1993
Deck/Cargo
Issued 8 October 1993 Resolved
MAKE PERMANENT REPAIRS TO NUMBER 2 CARGO TANK TOP, APPROX. 3/8" HOLE.
Condition: Unknown
Due 8 October 1993
Resolved 8 October 1993
Deck/Cargo
Issued 8 October 1993 Resolved
REPAIR OR REPLACE BROKEN CLUTCH HANDLE ON CARGO PUMP ENGINE.
Condition: Unknown
Due 8 October 1993
Resolved 8 October 1993
Construction/Loadline
Issued 8 October 1993 Resolved
MAKE PERMANENT REPAIRS TO ALL FRACTURES IN BOW VOID PORT SIDE CORNER WRAPPER.
Condition: Unknown
Due 8 October 1993
Resolved 8 October 1993
Construction/Loadline
Issued 10 December 1990 Resolved
MAKE PERMANENT REPAIR TO FRACTURED WELD AT 5TH CARGO TANK SIDE VERTICAL STARBOARD SIDE AT MAIN DECK, IN WAY OF #1 CARGO TANK
Condition: Unknown
Due 10 December 1990
Resolved 10 December 1990
Construction/Loadline
Issued 10 December 1990 Resolved
PRIOR TO NEXT LOADING RESTENCIL ALL DRAFT MARKS.
Condition: Unknown
Due 10 December 1990
Resolved 10 December 1990
Construction/Loadline
Issued 26 January 1989 Resolved
MAKE PERMANENT REPAIRS TO FRACTURE ON DECK AND SIDE OF #2P WING TANK TO THESATISFACTION OF THE ATTENDING MARINE INSPECTOR.
Condition: Unknown
Due 26 January 1989
Resolved 26 January 1989
Construction/Loadline
Issued 26 January 1989 Resolved
LOCATE, AND MAKE PERMANENT REPAIRS TO HOLE IN STERN VOID. REPAIRS TO BE MADE TO THE SATISFACTION OF THE ATTENDING MARINE INSPECTOR.
Condition: Unknown
Due 26 January 1989
Resolved 26 January 1989
Construction/Loadline
Issued 13 April 1988 Resolved
MAKE PERMANENT REPAIR TO A TWO (2) FT. CRACK IN HEAD LOG STARBOARD SIDE.
Condition: Unknown
Due 13 April 1988
Resolved 13 April 1988
Deck/Cargo
Issued 13 April 1988 Resolved
REALIGN CARGO PIPING OVER CONTAINMENT AND ATTACH BROKEN BRACKET TO DECK.
Condition: Unknown
Due 13 April 1988
Resolved 13 April 1988
Deck/Cargo
Issued 13 April 1988 Resolved
WHEN REPAIR TO PIPING NOTED IN ITEM H1 HAS BEEN COMPLETED, TEST SYSTEM TO 1 1/2 MAWP.
Condition: Unknown
Due 13 April 1988
Resolved 13 April 1988
Construction/Loadline
Issued 21 October 1985 Resolved
SPECIAL ATTION TO BILGE KNUCKED AREAS AT NEXT ALTERNATE INTERNAL EXAM OR NEXT DRYDOCKING.
Condition: Unknown
Due 21 October 1985
Resolved 21 October 1985

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.