Records from 1985 to 2000. Most recent: inspection, 27 March 2000.
A report is not offered for this hull: Its record holds only 2 of the seven kinds of material a report is built from: inspections, deficiencies, operational controls, tow-unit appearances, casualty records, dimensions and documentation. That is a statement about the record, not about the vessel. Reports.
Inspection history · 24
27 March 2000
Type not recorded
No type recorded · USCG Oceania District (dre) · USCG Oceania District (CGD-O) · Activity 637637
13 January 2000
Type not recorded
No type recorded · USCGC ASSATEAGUE (WPB 1337) · USCG Oceania District (CGD-O) · Activity 1518087
19 June 1998
Type not recorded
No type recorded · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1383886
1 March 1996
Administrative
Administrative · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 884939
17 March 1995
MARPOL Annex V Examination · COI Inspection
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1469791
18 March 1994
Re-Inspection · MARPOL Annex V Examination
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1461569
18 February 1994
Hull Examination
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1366984
22 July 1993
Administrative
Administrative · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 843154
26 April 1993
Re-Inspection
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1146554
28 April 1992
Administrative
Administrative · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 955547
2 March 1992
COI Inspection
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1256988
1 October 1991
Administrative
Administrative · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1249271
29 March 1991
Hull Examination
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 915351
11 June 1990
COI Inspection
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 909533
8 May 1990
Deficiency Check · Drydock Extension
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 916871
27 September 1989
Re-Inspection
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1314903
18 October 1988
Hull Examination
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 894997
16 March 1988
Hull Examination
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1339647
12 August 1987
Type not recorded
No type recorded · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1337835
17 June 1987
COI Inspection
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1007224
14 November 1986
Re-Inspection
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1017497
12 May 1986
Credit Drydock
Administrative · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 994477
25 October 1985
Type not recorded
No type recorded · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1295657
19 July 1985
Type not recorded
No type recorded · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1290132
Construction/Loadline
Issued 19 June 1998
No resolution recorded
Make permanent repairs to corroded water ballast line and flange leading into engine compartment.
Condition: Unknown
Due 31 July 1998 — due date passed with no resolution recorded
Navigation
Issued 19 June 1998
No resolution recorded
Properly secure forward steering housing.
Condition: Unknown
Due 31 July 1998 — due date passed with no resolution recorded
Construction/Loadline
Issued 19 June 1998
No resolution recorded
Replace forward retractable door's worn cable and shives.
Condition: Unknown
Due 31 July 1998 — due date passed with no resolution recorded
Construction/Loadline
Issued 19 June 1998
No resolution recorded
Make engine compartment vapor tight at bulkheads.
Condition: Unknown
Due 31 July 1998 — due date passed with no resolution recorded
Construction/Loadline
Issued 19 June 1998
No resolution recorded
Replace dry rotted gasket material on forward retractable door.
Condition: Unknown
Due 31 July 1998 — due date passed with no resolution recorded
Documentation
Issued 2 March 1992
Resolved
THE VESSEL OPERATOR SHALL HOLD AT LEAST AN FCC MARINE OPERATOR PERMIT TO OPERATE THE VHF-FM RADIO.
Condition: Unknown
Due 2 March 1992
Resolved 2 March 1992
Engineering
Issued 11 June 1990
Resolved
PROVIDE A FLAME CUP FOR THE RACOR FUEL FILTER.
Condition: Unknown
Due 11 June 1990
Resolved 11 June 1990
Lifesaving
Issued 11 June 1990
Resolved
PROVIDE 6 RED HAND FLARES APPROVED UNDER 46 CFR 160.021 THAT HAVE BEEN MANUFACTURED WITHIN THE LAST THREE YEARS.
Condition: Unknown
Due 11 June 1990
Resolved 11 June 1990
Documentation
Issued 27 September 1989
Resolved
PRODUCE A VALID FCC RADIO SAFETY CERTIFICATE FORM 824 PRIOR TO CARRYING PASSENGERS MORE THAN 1000 FEET FROM SHORE.
Condition: Unknown
Due 27 September 1989
Resolved 27 September 1989
Documentation
Issued 18 October 1988
Resolved
MAKE VESSEL AVAILABLE FOR REINSPECTION BY A MARINE INSPECTOR. VESSEL MAY NOT CARRY PASSENGERS UNTIL ABOVE ITEM COMPLETE.
Condition: Unknown
Due 18 October 1988
Resolved 18 October 1988
Unknown
Issued 17 June 1987
Resolved
OBTAIN AND APPLY CURRENT RENEWAL STICKER ON THE VESSEL'S CERTIFICATE OF DOCUMENTATION.
Condition: Unknown
Due 17 June 1987
Resolved 17 June 1987
Unknown
Issued 17 June 1987
Resolved
PROVIDE AND INSTALL A CORRECTLY CERTIFIED FLOAT FREE LINK FOR THE BUOYANT APPARATUS IN ACCORDANCE WITH 46 CFR 180.20 AND 160.073.
Condition: Unknown
Due 17 June 1987
Resolved 17 June 1987
Unknown
Issued 17 June 1987
Resolved
PROVIDE 1 ADDITIONAL B-II PORTABLE FIRE EXTINGUISHER.
Condition: Unknown
Due 17 June 1987
Resolved 17 June 1987
Unknown
Issued 17 June 1987
Resolved
REPAIR OR RENEW THE WATERLIGHT FOR THE RING BUOY. UNTIL THIS ITEM IS COMPLETED, THE VESSEL IS RESTRICTED TO DAYLIGHT OPERATION ONLY.
Condition: Unknown
Due 17 June 1987
Resolved 17 June 1987
Unknown
Issued 17 June 1987
Resolved
REPAIR OR RENEW WATERLIGHT FOR THE BUOYANT APPARATUS. UNTIL THIS ITEM IS COMPLETED, THE VESSEL IS RESTRICTED TO DAYLIGHT OPERATION ONLY.
Condition: Unknown
Due 17 June 1987
Resolved 17 June 1987
Unknown
Issued 14 November 1986
Resolved
REPAIR OR REPLACE RING BUOY.
Condition: Unknown
Due 14 November 1986
Resolved 14 November 1986
Navigation
Issued 19 July 1985
Resolved
REPLACE OR REPAIR STEERING PUMP BRAKING GASKETS.
Condition: Unknown
Due 19 July 1985
Resolved 19 July 1985
Documentation
Issued 19 July 1985
Resolved
PLACE UNDER TRANSPARENT COVER COI AND SEND TEMPORARY TO [name withheld].
Condition: Unknown
Due 19 July 1985
Resolved 19 July 1985
Fire Fighting
Issued 19 July 1985
Resolved
SEND OUT FOR TESTING AND SERVICING ALL PORTABLE FIRE EXTINGUISHERS.
Condition: Unknown
Due 19 July 1985
Resolved 19 July 1985
Navigation
Issued 19 July 1985
Resolved
REPAIR OR REPLACE STARBOARD RUNNING LIGHT.
Condition: Unknown
Due 19 July 1985
Resolved 19 July 1985