5 January 2022
Administrative Inspection
Administrative · Marine Safety Detachment Santa Barbara · USCG Southwest District (CGD-SW) · Activity 7376204
14 June 2021
Annual Inspection
Physical examination · Marine Safety Detachment Santa Barbara · USCG Southwest District (CGD-SW) · Activity 7208106
12 December 2020
Administrative Inspection
Administrative · Marine Safety Detachment Santa Barbara · USCG Southwest District (CGD-SW) · Activity 7110820
15 October 2020
Administrative Inspection
Administrative · Marine Safety Detachment Santa Barbara · USCG Southwest District (CGD-SW) · Activity 7078034
15 June 2020
Annual Inspection
Physical examination · Marine Safety Detachment Santa Barbara · USCG Southwest District (CGD-SW) · Activity 6974772
11 December 2019
Deficiency Check · Hull Examination
Physical examination · Marine Safety Detachment Santa Barbara · USCG Southwest District (CGD-SW) · Activity 6872236
2 May 2019
Annual Inspection
Physical examination · Marine Safety Detachment Santa Barbara · USCG Southwest District (CGD-SW) · Activity 6655086
26 April 2018
Annual Inspection
Physical examination · Marine Safety Detachment Santa Barbara · USCG Southwest District (CGD-SW) · Activity 6389927
17 January 2018
Hull Examination
Physical examination · Marine Safety Detachment Santa Barbara · USCG Southwest District (CGD-SW) · Activity 6336424
15 March 2017
COI Inspection · Deficiency Check · DAPI Audit
Physical examination · Marine Safety Detachment Santa Barbara · USCG Southwest District (CGD-SW) · Activity 6095962
19 May 2016
Deficiency Check · Annual Inspection
Physical examination · Marine Safety Detachment Santa Barbara · USCG Southwest District (CGD-SW) · Activity 5867518
14 March 2016
Hull Examination · Deficiency Check
Physical examination · Marine Safety Detachment Santa Barbara · USCG Southwest District (CGD-SW) · Activity 5829444
01 - Certificates & Documentation › 011 - Ships Certificates › Certificate of Inspection (COI)
Issued 5 January 2022
No resolution recorded
A vessel that is exposed to salt water more than three months in any 12 month period since the last examination must undergo a drydock examination and an internal structural at least once every two years. Vessel was due for drydock examination 21DEC2021. A satisfactory drydock examination must be completed prior to departure.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
18 - Maritime Labour Convention (Not Applicable to PSC Exams conducted in the U.S.) › N/A - No Subsystem › Other (Conditions of employment)
Issued 14 June 2021
Resolved
Alcohol test swabs expired. Provide current testing devices.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 28 June 2021
Resolved 23 June 2021
Resolution: Vessel received new alcohol testing devices.
11 - Life Saving Appliances › N/A - No Subsystem › Other (life saving)
Issued 14 June 2021
Resolved
EPIRB tests and portable fire extinguisher inspections not logged. Provide logs.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 28 June 2021
Resolved 16 June 2021
Resolution: Vessel provided completed logs.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 14 June 2021
Resolved
Exhaust lagging damaged/missing on port and starboard main engine exhausts. Replace.
Condition: Damaged By Earlier Event
Action required: 16 - Rectify deficiencies w/in 14 days
Due 28 June 2021
Resolved 16 June 2021
Resolution: Vessel renewed lagging.
02 - Structural Conditions › N/A - No Subsystem › Ballast, fuel and other tanks
Issued 14 June 2021
Resolved
Flame screens for both fuel tank vents clogged with paint. Replace.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 28 June 2021
Resolved 16 June 2021
Resolution: Vessel replaced flame screens.
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 14 June 2021
Resolved
Vessel installed washer & dryer and moved freezer. Provide electrical plans showing materials, overcurrent protection and load.
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 13 July 2021
Resolved 14 July 2021
Resolution: Vessel provided details of changes.
Engineering › Bilge Water Management System › Valve
Issued 15 March 2017
Resolved
Install check valves in all bilge suction lines.
Condition: Placed in Improper Service
Action required: 705 - Other - as specified
Due 15 April 2017
Resolved 5 June 2017
Resolution: Check valves installed.
Stability › Watertight Integrity › General
Issued 15 March 2017
Resolved
Repair forward watertight door open indicator light.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 15 April 2017
Resolved 11 May 2017
Resolution: Indicator light tested sat.
Operations/Management › Drug and Alcohol Testing › Recordkeeping
Issued 15 March 2017
Resolved
Provide drug testing program documentation.
Action required: 705 - Other - as specified
Due 15 April 2017
Resolved 11 April 2017
Documentation › Markings/Placards › Warning Signs
Issued 15 March 2017
Resolved
Stencil all electrical panels to indicate service/function.
Action required: 705 - Other - as specified
Due 15 March 2017
Resolved 15 March 2017
Resolution: Corrected during inspection.
Lifesaving › Inflatable Liferafts › Painter
Issued 15 March 2017
Resolved
Properly rig painter to hydro release weak link.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 15 March 2017
Resolved 15 March 2017
Resolution: Corrected during inspection.
Communications › Radio Communications › EPIRB
Issued 19 May 2016
Resolved
Renew hydrostatic release for the EPIRB, restricted to 3nm from shore.
Action required: 705 - Other - as specified
Due 20 May 2016
Resolved 20 May 2016
Resolution: New hydro-static release installed.
Electrical › Electrical Distribution System (service) › Wiring
Issued 19 May 2016
Resolved
Hard wire ice box power cord in galley.
Action required: 705 - Other - as specified
Due 19 June 2016
Resolved 6 July 2016
Resolution: Power cord relocated to outlet not affecting WTD.
Lifesaving › Lifejacket/PFD (Type I) › Retroreflective Material
Issued 19 May 2016
Resolved
Renew as needed retro-tape for LJs and liferings.
Action required: 705 - Other - as specified
Due 20 May 2016
Resolved 20 May 2016
Resolution: Retro renewed.
Construction/Loadline › Hull › Bottom Plating
Issued 14 March 2016
Resolved
Clad weld isolated pits aft galley void.
Action required: 705 - Other - as specified
Due 31 March 2016
Resolved 18 March 2016
Resolution: Clad weld completed
Construction/Loadline › Hull › Bottom Plating
Issued 14 March 2016
Resolved
Clad weld isolated pits fwd lower salon.
Action required: 705 - Other - as specified
Due 31 March 2016
Resolved 18 March 2016
Resolution: Clad weld completed
Electrical › Electrical Distribution System (service) › Wiring
Issued 14 March 2016
Resolved
Remove dead end wire in lower salon void.
Action required: 705 - Other - as specified
Due 31 March 2016
Resolved 18 March 2016
Resolution: Wire removed
Engineering › Bilge Water Management System › Valve
Issued 14 March 2016
Resolved
Prove proper operation of fwd peak isolation valve.
Action required: 705 - Other - as specified
Due 31 March 2016
Resolved 18 March 2016
Resolution: Isolation valve operational
Operations/Management › Bilge/Bilge System Management › Control of Oil Mixtures
Issued 14 March 2016
Resolved
Clean bilge in E/R for inspection.
Action required: 705 - Other - as specified
Due 31 March 2016
Resolved 15 March 2016
Resolution: E/R cleaned
Operations/Management › Bilge/Bilge System Management › Control of Oil Mixtures
Issued 14 March 2016
Resolved
Clean laz bilge for inspection.
Action required: 705 - Other - as specified
Due 31 March 2016
Resolved 15 March 2016
Resolution: Laz bilge cleaned
Engineering › Pressure Vessel › Shell Plate
Issued 14 March 2016
Resolved
Prepare air tanks for internal inspection.
Action required: 705 - Other - as specified
Due 31 March 2016
Resolved 18 March 2016
Resolution: Internals completed.
Deck/Cargo › Holds/Tanks › Watertight Door
Issued 14 March 2016
Resolved
Properly adjust WTDs
Action required: 705 - Other - as specified
Due 31 March 2016
Resolved 15 March 2016
Resolution: WTDs properly adjusted.
Electrical › Electrical Distribution System (service) › Wiring
Issued 14 March 2016
Resolved
Hard wire ice box.
Action required: 705 - Other - as specified
Due 31 March 2016
Resolved 18 March 2016
Resolution: Ice box hard wired.