MAURY USCG vessel records
← All vessels

DOUG C.

DOUG C. is a 1974 offshore supply vessel. The Coast Guard has recorded 12 inspections since 2016, most recently in January 2022, along with 23 deficiencies — 1 with no resolution recorded —, 1 operational control, 1 with no removal date recorded and 1 casualty investigation in 2013.

Records from 2013 to 2022. Most recent: operational control imposed, 5 January 2022.

Built
1974
Last inspected
5 January 2022
Documentation
Not in the documentation file of 10 August 2026
Controls
1 with no removal date recorded

This record may be incomplete: the most recent inspection recorded for this vessel was 4 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 23 August 2026, retrieved 5 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Offshore class in Maury's sources begin in 2016.

Inspection record

Last inspected 5 January 2022
Operational controls 1 with no removal date recorded
Years with a record 7 calendar years (2016–2022)
Every line above is a count of records the US Coast Guard wrote, or a date it recorded. A blank resolution means none was recorded in this data; it does not establish that a deficiency is outstanding. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Identity

WTX4517
Flag
UNITED STATES
Maury page id
psix-48072

Documentation record

Tonnage as PSIX records it93 - Regulatory (Subpart C or D), Gross Ton
63 - Regulatory (Subpart C or D), Net Ton
This hull's Official Number is not in the NVDC file dated 10 August 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.
Vessel history report
Every record for this hull, in one document — $299

Every recorded inspection, 2016 to 2026 for this class, in one chronology · every deficiency, with system, dates and resolution · operational controls imposed and removed · every name this hull has been recorded under · the vessels it was inspected alongside, and when · how its record compares with hulls of similar age and size, as a fact about the population and never a judgement about this vessel.

Read one first, in full: a forty-year chronology · a hull that changed operators four times · the sparse case, shown as an example, not for sale.

This report is in development and is not for sale yet. There is no date, and nothing is charged. Leave an email and we will tell you when it exists, once.

Inspection history · 12

5 January 2022 Administrative Inspection
Administrative · Marine Safety Detachment Santa Barbara · USCG Southwest District (CGD-SW) · Activity 7376204
14 June 2021 Annual Inspection
Physical examination · Marine Safety Detachment Santa Barbara · USCG Southwest District (CGD-SW) · Activity 7208106
12 December 2020 Administrative Inspection
Administrative · Marine Safety Detachment Santa Barbara · USCG Southwest District (CGD-SW) · Activity 7110820
15 October 2020 Administrative Inspection
Administrative · Marine Safety Detachment Santa Barbara · USCG Southwest District (CGD-SW) · Activity 7078034
15 June 2020 Annual Inspection
Physical examination · Marine Safety Detachment Santa Barbara · USCG Southwest District (CGD-SW) · Activity 6974772
11 December 2019 Deficiency Check · Hull Examination
Physical examination · Marine Safety Detachment Santa Barbara · USCG Southwest District (CGD-SW) · Activity 6872236
2 May 2019 Annual Inspection
Physical examination · Marine Safety Detachment Santa Barbara · USCG Southwest District (CGD-SW) · Activity 6655086
26 April 2018 Annual Inspection
Physical examination · Marine Safety Detachment Santa Barbara · USCG Southwest District (CGD-SW) · Activity 6389927
17 January 2018 Hull Examination
Physical examination · Marine Safety Detachment Santa Barbara · USCG Southwest District (CGD-SW) · Activity 6336424
15 March 2017 COI Inspection · Deficiency Check · DAPI Audit
Physical examination · Marine Safety Detachment Santa Barbara · USCG Southwest District (CGD-SW) · Activity 6095962
19 May 2016 Deficiency Check · Annual Inspection
Physical examination · Marine Safety Detachment Santa Barbara · USCG Southwest District (CGD-SW) · Activity 5867518
14 March 2016 Hull Examination · Deficiency Check
Physical examination · Marine Safety Detachment Santa Barbara · USCG Southwest District (CGD-SW) · Activity 5829444

Deficiency record · 23

01 - Certificates & Documentation › 011 - Ships Certificates › Certificate of Inspection (COI)
Issued 5 January 2022 No resolution recorded
A vessel that is exposed to salt water more than three months in any 12 month period since the last examination must undergo a drydock examination and an internal structural at least once every two years. Vessel was due for drydock examination 21DEC2021. A satisfactory drydock examination must be completed prior to departure.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
18 - Maritime Labour Convention (Not Applicable to PSC Exams conducted in the U.S.) › N/A - No Subsystem › Other (Conditions of employment)
Issued 14 June 2021 Resolved
Alcohol test swabs expired. Provide current testing devices.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 28 June 2021
Resolved 23 June 2021
Resolution: Vessel received new alcohol testing devices.
11 - Life Saving Appliances › N/A - No Subsystem › Other (life saving)
Issued 14 June 2021 Resolved
EPIRB tests and portable fire extinguisher inspections not logged. Provide logs.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 28 June 2021
Resolved 16 June 2021
Resolution: Vessel provided completed logs.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 14 June 2021 Resolved
Exhaust lagging damaged/missing on port and starboard main engine exhausts. Replace.
Condition: Damaged By Earlier Event
Action required: 16 - Rectify deficiencies w/in 14 days
Due 28 June 2021
Resolved 16 June 2021
Resolution: Vessel renewed lagging.
02 - Structural Conditions › N/A - No Subsystem › Ballast, fuel and other tanks
Issued 14 June 2021 Resolved
Flame screens for both fuel tank vents clogged with paint. Replace.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 28 June 2021
Resolved 16 June 2021
Resolution: Vessel replaced flame screens.
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 14 June 2021 Resolved
Vessel installed washer & dryer and moved freezer. Provide electrical plans showing materials, overcurrent protection and load.
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 13 July 2021
Resolved 14 July 2021
Resolution: Vessel provided details of changes.
Engineering › Bilge Water Management System › Valve
Issued 15 March 2017 Resolved
Install check valves in all bilge suction lines.
Condition: Placed in Improper Service
Action required: 705 - Other - as specified
Due 15 April 2017
Resolved 5 June 2017
Resolution: Check valves installed.
Stability › Watertight Integrity › General
Issued 15 March 2017 Resolved
Repair forward watertight door open indicator light.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 15 April 2017
Resolved 11 May 2017
Resolution: Indicator light tested sat.
Operations/Management › Drug and Alcohol Testing › Recordkeeping
Issued 15 March 2017 Resolved
Provide drug testing program documentation.
Action required: 705 - Other - as specified
Due 15 April 2017
Resolved 11 April 2017
Documentation › Markings/Placards › Warning Signs
Issued 15 March 2017 Resolved
Stencil all electrical panels to indicate service/function.
Action required: 705 - Other - as specified
Due 15 March 2017
Resolved 15 March 2017
Resolution: Corrected during inspection.
Lifesaving › Inflatable Liferafts › Painter
Issued 15 March 2017 Resolved
Properly rig painter to hydro release weak link.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 15 March 2017
Resolved 15 March 2017
Resolution: Corrected during inspection.
Communications › Radio Communications › EPIRB
Issued 19 May 2016 Resolved
Renew hydrostatic release for the EPIRB, restricted to 3nm from shore.
Action required: 705 - Other - as specified
Due 20 May 2016
Resolved 20 May 2016
Resolution: New hydro-static release installed.
Electrical › Electrical Distribution System (service) › Wiring
Issued 19 May 2016 Resolved
Hard wire ice box power cord in galley.
Action required: 705 - Other - as specified
Due 19 June 2016
Resolved 6 July 2016
Resolution: Power cord relocated to outlet not affecting WTD.
Lifesaving › Lifejacket/PFD (Type I) › Retroreflective Material
Issued 19 May 2016 Resolved
Renew as needed retro-tape for LJs and liferings.
Action required: 705 - Other - as specified
Due 20 May 2016
Resolved 20 May 2016
Resolution: Retro renewed.
Construction/Loadline › Hull › Bottom Plating
Issued 14 March 2016 Resolved
Clad weld isolated pits aft galley void.
Action required: 705 - Other - as specified
Due 31 March 2016
Resolved 18 March 2016
Resolution: Clad weld completed
Construction/Loadline › Hull › Bottom Plating
Issued 14 March 2016 Resolved
Clad weld isolated pits fwd lower salon.
Action required: 705 - Other - as specified
Due 31 March 2016
Resolved 18 March 2016
Resolution: Clad weld completed
Electrical › Electrical Distribution System (service) › Wiring
Issued 14 March 2016 Resolved
Remove dead end wire in lower salon void.
Action required: 705 - Other - as specified
Due 31 March 2016
Resolved 18 March 2016
Resolution: Wire removed
Engineering › Bilge Water Management System › Valve
Issued 14 March 2016 Resolved
Prove proper operation of fwd peak isolation valve.
Action required: 705 - Other - as specified
Due 31 March 2016
Resolved 18 March 2016
Resolution: Isolation valve operational
Operations/Management › Bilge/Bilge System Management › Control of Oil Mixtures
Issued 14 March 2016 Resolved
Clean bilge in E/R for inspection.
Action required: 705 - Other - as specified
Due 31 March 2016
Resolved 15 March 2016
Resolution: E/R cleaned
Operations/Management › Bilge/Bilge System Management › Control of Oil Mixtures
Issued 14 March 2016 Resolved
Clean laz bilge for inspection.
Action required: 705 - Other - as specified
Due 31 March 2016
Resolved 15 March 2016
Resolution: Laz bilge cleaned
Engineering › Pressure Vessel › Shell Plate
Issued 14 March 2016 Resolved
Prepare air tanks for internal inspection.
Action required: 705 - Other - as specified
Due 31 March 2016
Resolved 18 March 2016
Resolution: Internals completed.
Deck/Cargo › Holds/Tanks › Watertight Door
Issued 14 March 2016 Resolved
Properly adjust WTDs
Action required: 705 - Other - as specified
Due 31 March 2016
Resolved 15 March 2016
Resolution: WTDs properly adjusted.
Electrical › Electrical Distribution System (service) › Wiring
Issued 14 March 2016 Resolved
Hard wire ice box.
Action required: 705 - Other - as specified
Due 31 March 2016
Resolved 18 March 2016
Resolution: Ice box hard wired.

Casualty record · 1

19 February 2013Routine · role: Involved in a Marine Casualty · serious marine incident, as classified · 1 dead · activity 4536534
Each line is an incident investigation the Coast Guard recorded with this hull among the vessels involved, with the date and the classification the Coast Guard gave it. Involvement is not fault. The investigation narrative is not published. Source: IIR, through 2026.

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.