POINT LOMA

POINT LOMA is a 1974 passenger vessel (inspected). The Coast Guard has recorded 82 inspections since 1986, most recently in April 2026, along with 147 deficiencies and 1 casualty investigation in 2018.

Records from 1986 to 2026. Most recent: inspection, 30 April 2026.

Built
1974
Last inspected
30 April 2026
Documentation
Valid · documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

WDD8896
Flag
UNITED STATES
367304250
Maury page id
psix-48074

Inspections, by type

…with no type recorded14
Years with a record 36 calendar years (1986–2026)
The 82 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Passenger Ship class in Maury's sources begin in 1977.

Documentation record

Registered dimensions (L × B × D)48.4 ft × 15.8 ft × 5.7 ft
Registered tonnagegross 32 / net 22
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
BuilderEDWIN WOOD · ELMA, WA, UNITED STATES · built 1974
Hull materialWood
PropulsionDiesel Reduction
Hull shapeNot recorded
Hull configurationNot recorded
Hailing portSAN DIEGO, CA
Trade endorsementsCoastwise, unrestricted, Registry
DocumentationValid · issued 6 May 2026 · expires 31 May 2027
Service, as the file records itPassenger (Inspected)
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it32 - Regulatory (Subpart C or D), Gross Ton
22 - Regulatory (Subpart C or D), Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 September 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.

Radio station licence

WDD8896MMSI 367304250 · active · compulsorily equipped · granted 23 May 2017, expires 20 July 2027
WCX6458MMSI not assigned · expired · compulsorily equipped · granted 29 July 1997, cancelled 29 September 2007
WCV9817MMSI not assigned · expired · compulsorily equipped · granted 23 February 1996, cancelled 29 April 2006 · licensed under a name not among this hull’s recorded names (not shown)
FCC Universal Licensing System ship-station file of 6 September 2026, matched to this hull on its US Official Number. Status and dates are the file’s own. The licensee is not read from the file and is not shown. A lapsed licence’s MMSI is still the number the vessel transmitted under while it was valid.

Inspection history · 82

30 April 2026 Deficiency Check · Annual Inspection
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 8367633
13 November 2025 Drydock Exam · Internal Structural Exam · Deficiency Check
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 8267317
24 March 2025 Deficiency Check · COI Inspection
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 8089690
15 May 2024 Annual Inspection
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 7912782
14 December 2023 Internal Structural Exam · Examination of Repairs · Drydock Exam
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 7839283
8 June 2023 Annual Inspection
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 7709421
27 February 2023 In-Service Inspection
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 7662827
25 May 2022 Deficiency Check · Annual Inspection
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 7523405
6 January 2022 Internal Structural Exam · Hull Examination
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 7376438
28 April 2021 Annual Inspection · Deficiency Check
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 7184571
1 April 2020 COI Inspection · Deficiency Check
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 6930719
16 January 2020 Deficiency Check · Hull Examination
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 6890654
21 October 2019 Administrative Inspection
Administrative · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 6839011
9 April 2019 Annual Inspection
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 6658782
15 June 2018 Type not recorded
No type recorded · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 6445300
14 June 2018 Damage Survey
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 6448087
28 March 2018 Annual Inspection · Deficiency Check
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 6380300
18 January 2018 Examination of Repairs · Hull Examination
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 6339692
20 April 2017 Deficiency Check · Annual Inspection
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 6128901
21 April 2016 Deficiency Check · Annual Inspection
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 5859308
16 February 2016 Internal Structural Exam · Deficiency Check · Hull Examination
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 5815763
12 June 2014 Annual Inspection · DAPI Audit
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 4886205
25 January 2010 Internal Structural Exam · Hull Examination
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 3669747
12 September 2008 DAPI Audit · Deficiency Check · Annual Inspection
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 3317196
22 February 2008 Hull Examination · Deficiency Check
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 3151887
12 September 2007 Annual Inspection · Deficiency Check
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 3053921
26 May 2006 Deficiency Check · Annual Inspection
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 2657086
28 April 2006 In-Service Inspection
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 2643112
7 April 2006 Internal Structural Exam · Hull Examination
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 2643102
15 June 2005 COI Inspection · Deficiency Check
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 2371633
18 January 2005 Hull Examination
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 2262703
15 June 2004 Deficiency Check · Re-Inspection
Physical examination · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 2091544
7 November 2003 Deficiency Check
Physical examination · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 1944014
2 September 2003 Annual Inspection
Physical examination · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 1894797
14 January 2003 Hull Examination
Physical examination · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 1728598
17 December 2002 Internal Structural Exam · Drydock Extension
Physical examination · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 1714494
3 October 2002 Deficiency Check
Physical examination · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 1683783
17 September 2002 Re-Inspection
Physical examination · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 1674324
30 August 2001 Deficiency Check
Physical examination · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 1073427
19 August 2001 Deficiency Check
Physical examination · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 1070450
13 July 2001 Type not recorded
No type recorded · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 1067449
19 June 2001 Re-Inspection
Physical examination · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 1391620
14 February 2001 Type not recorded
No type recorded · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 1443211
20 June 2000 COI Inspection
Physical examination · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 1399408
4 May 2000 Type not recorded
No type recorded · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 723120
11 September 1999 Type not recorded
No type recorded · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 41710
7 July 1999 Plan Review "T" Boat
Administrative · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 1092723
22 June 1999 Re-Inspection
Physical examination · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 1429166
15 April 1999 Type not recorded
No type recorded · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 213056
15 April 1999 Type not recorded
No type recorded · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 227883
18 March 1999 Type not recorded
No type recorded · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 1372599
22 January 1999 Plan Review "T" Boat
Administrative · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 1123569
7 December 1998 Hull Examination
Physical examination · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 1381401
9 November 1998 Type not recorded
No type recorded · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 1404637
30 October 1998 Type not recorded
No type recorded · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 50727
23 July 1998 Type not recorded
No type recorded · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 723119
1 June 1998 Re-Inspection
Physical examination · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 1406349
18 June 1997 COI Inspection
Physical examination · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 1407917
8 May 1997 Hull Examination
Physical examination · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 1414797
29 October 1996 Deficiency Check
Physical examination · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 1166677
16 August 1996 Hull Examination
Physical examination · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 1388114
9 May 1996 Re-Inspection
Physical examination · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 1400365
5 April 1996 Administrative
Administrative · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 1078643
23 March 1996 Type not recorded
No type recorded · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 48080
23 March 1996 Damage Survey
Physical examination · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 1409470
24 January 1996 Type not recorded
No type recorded · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 147028
18 December 1995 Administrative
Administrative · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 882569
17 February 1995 COI Inspection · Hull Examination
Physical examination · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 1414410
18 February 1994 Hull Examination · Re-Inspection
Physical examination · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 1403731
1 February 1993 Re-Inspection · Drydock Extension
Physical examination · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 1412468
18 June 1992 Type not recorded
No type recorded · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 1260175
19 February 1992 Hull Examination · COI Inspection
Physical examination · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 949648
9 October 1991 Drydock Extension
Administrative · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 936134
20 February 1991 Re-Inspection
Physical examination · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 1239582
16 March 1990 Hull Examination
Physical examination · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 930600
6 February 1990 Re-Inspection
Physical examination · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 904364
20 September 1989 Drydock Extension
Administrative · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 888442
24 April 1989 Deficiency Check
Physical examination · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 1198524
12 April 1989 COI Inspection
Physical examination · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 1279781
21 March 1988 Hull Examination · Re-Inspection
Physical examination · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 1278257
14 April 1987 Re-Inspection
Physical examination · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 1322784
17 April 1986 Credit Drydock · COI Inspection
Physical examination · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 996235

Deficiency record · 147

03 - Water/Weathertight Conditions › N/A - No Subsystem › Railing, gangway, walkway and means for safe passage
Issued 30 April 2026 Resolved
Observed railing gaps exceeding more than 12 inches. Vessel is to add additional courses (able to withstand 200 lbs of pressure) to meet the requirements of less than 12 inches of gap/s. 46CFR177.920(g)
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 2 June 2026
Resolution: images provided with sufficient line added to the courses. All SAT
11 - Life Saving Appliances › N/A - No Subsystem › Other (life saving)
Issued 30 April 2026 Resolved
Observed a non-rigid rescue ladder. Vessel is to have deployable rigid rescue ladder with an assist line, sufficient rung space/s, and the side of the hull for proper footing (capable of supporting at least 2 persons-370LBS). 46CFR175.118(c)(4)
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 2 June 2026
Resolution: POC provided images of new ladder and tested with 2 persons. All SAT
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 24 March 2025 Resolved
Vessel was found to be missing an interlock on the shore power and generator circuit panel. Provide vessel with adequate means to prevent both circuits from being energized simultaneously.
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 1 April 2025
Resolution: Received photo of interlock installed.
11 - Life Saving Appliances › N/A - No Subsystem › Maintenance of Life Saving Appliances
Issued 15 May 2024 Resolved
Lifeline on two life floats and an inner line for securing the basket were wasted, replace with UV resistant line to ensure all components of the life floats are operational.
Action required: 17 - Rectify deficiencies prior to departure
Due 15 May 2024
Resolved 6 June 2024
Resolution: Rcvd evidence of the issue being fixed
07 - Fire Safety › N/A - No Subsystem › Fire detection and alarm system
Issued 15 May 2024 Resolved
Integrated smoke detectors were not integrated and did not all set each other off. Troubleshoot and ensure the smoke detectors were integrated.
Action required: 17 - Rectify deficiencies prior to departure
Due 15 May 2024
Resolved 15 May 2024
Resolution: Sent documentation that the systems are now operational.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 15 May 2024 Resolved
Shaft seal was leaking at a rate of one drop per second on the starboard side main shaft. Tighten packing glands to lesson or eliminate the leak.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 6 June 2024
Resolution: Rcvd video of shafts without leakage
09 - Working and Living Conditions › 092 - Working Conditions › Protection machinery
Issued 15 May 2024 Resolved
Starboard side main engines guard was missing. Replace guard.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 6 June 2024
Resolution: Rcvd picture of gaurds in place.
05 - Radio Communications › N/A - No Subsystem › MF/HF Radio installation
Issued 25 May 2022 Resolved
A vessel must comply with the applicable requirements for any radio and Electronic Position Indicating Radiobeacon (EPIRB) installations, including the requirements for a station license and installation certificates to be issued by the Federal Communications Commission, as set forth in 47 CFR part 80. Install a radio with DSC after installation. After installation have station certified buy an FCC certified technician.
Condition: Invalid
Action required: 50 - Rectify deficiencies w/in 30 days
Due 25 June 2022
Resolved 24 June 2022
Resolution: O/O sent photo of rectified deficiency.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 25 May 2022 Resolved
Electrical equipment on a vessel must be installed and maintained to: (a) Provide services necessary for safety under normal and emergency conditions; (b) Protect passengers, crew, other persons, and the vessel from electrical hazards, including fire, caused by or originating in electrical equipment, and electrical shock; (c) Minimize accidental personnel contact with energized parts; and (d) Prevent electrical ignition of flammable vapors. Clean up electrical wiring in the engine room and remove surge protector from under operation station.
Condition: Invalid
Action required: 50 - Rectify deficiencies w/in 30 days
Due 25 June 2022
Resolved 24 June 2022
Resolution: O/O sent photo of rectified deficiency.
11 - Life Saving Appliances › N/A - No Subsystem › Radio life-saving appliances
Issued 28 April 2021 Resolved
Each item of lifesaving equipment with an expiration date on it must be replaced if the expiration date has passed. EPIRB NOAA registration expired date DEC 2020.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 12 May 2021
Resolved 10 May 2021
Resolution: Received documentation of renewal.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 28 April 2021 Resolved
STBD Propulsion shaft seal packing excessive water leak. Make necessary repairs in accordance with Manufacturers instructions.
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 12 May 2021
Resolved 10 May 2021
Resolution: Corrected deficiency; witnessed by USCG MI.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Auxiliary engine
Issued 28 April 2021 Resolved
Generator oil sending unit leaking. Make necessary repairs in accordance with Manufacturers instructions.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 12 May 2021
Resolved 10 May 2021
Resolution: Corrected deficiency; witnessed by USCG MI.
01 - Certificates & Documentation › 012 - Crew Certificates › Certificates for radio personnel
Issued 1 April 2020 Resolved
Provide proof of a Marine Radio Operators permit for all Licensed mariners.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 1 May 2020
Resolved 15 April 2020
Resolution: MI's shown new permit
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 1 April 2020 Resolved
Ensure proper waterlight lanyard is installed on ring life buoy.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 14 April 2020
Resolved 15 April 2020
Resolution: Verified lanyard installed
10 - Safety of Navigation › N/A - No Subsystem › Magnetic compass
Issued 1 April 2020 Resolved
Repair magnetic compass light
Action required: 50 - Rectify deficiencies w/in 30 days
Due 1 May 2020
Resolved 15 April 2020
Resolution: Verified repaired light
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 9 April 2019 Resolved
Provide 04 fuel hoses with double hose clamps at both ends.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 23 April 2019
Resolved 23 April 2019
Resolution: Vessel rep provided all fuel hoses with double hose clamps.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 9 April 2019 Resolved
Provide lazarette with bilge suction line and cut-off valve.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 23 April 2019
Resolved 23 April 2019
Resolution: Vessel rep installed bilge suction and valve in lazarette.
Lifesaving › Lifefloat › Netting
Issued 28 March 2018 Resolved
1. Make repairs to lifefloat netting
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 28 March 2018
Resolved 28 April 2018
Resolution: Life float netting fixed
Electrical › Electric Generation Source (service) › Panelboard
Issued 28 March 2018 Resolved
2. Provide voltmeter, ammeter, and herzt gauge for electrical installations operating at potentials of 50 volts or more. (Generator)
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 28 April 2018
Resolved 21 May 2018
Resolution: Ammeter , voltmeter, and hertz gauge .
Construction/Loadline › Hull › Side Shell
Issued 28 March 2018 Resolved
Make repairs on wood planking IWO starboard aft quarter/corner.
Condition: Damaged By Earlier Event
Action required: 50 - Rectify deficiencies w/in 30 days
Due 28 April 2018
Resolved 24 April 2018
Engineering › Bilge Water Management System › Hose
Issued 28 March 2018 Resolved
Replace flexible suction line for lazzerette bilge manifold.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 28 April 2018
Resolved 24 May 2018
Construction/Loadline › Structures › Ventilators
Issued 28 March 2018 Resolved
Make repairs to port and starboard gunwahle corners (not structural but potential for downflooding)
Condition: Damaged By Earlier Event
Action required: 50 - Rectify deficiencies w/in 30 days
Due 28 April 2018
Resolved 24 May 2018
Engineering › Fuel Oil Storage/Transfer System › Piping
Issued 28 March 2018 Resolved
Properly label fuel fills
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 28 April 2018
Resolved 24 May 2018
Electrical › Electric Generation Source (service) › Circuit Breaker
Issued 20 April 2017 Resolved
provide blanks for swithcboard in E/R
Action required: 705 - Other - as specified
Due 20 May 2017
Resolved 19 May 2017
Resolution: Provided blanks for switchboard in E/R
Electrical › Electric Supply System (service) › Cable
Issued 20 April 2017 Resolved
Remove battery cable from bilges.
Action required: 705 - Other - as specified
Due 20 May 2017
Resolved 19 May 2017
Resolution: Secured battery cables above bilges.
Electrical › Electrical Distribution System (service) › Wiring
Issued 20 April 2017 Resolved
Cap or remove deadend wire from forward starboard sider E/R.
Action required: 705 - Other - as specified
Due 20 May 2017
Resolved 19 May 2017
Resolution: Caped deadend wire from FWD starboard side E/R
Lifesaving › Lifefloat › Float-free Link
Issued 20 April 2017 Resolved
Provide 02 weak links for life floats with proper tag.
Action required: 705 - Other - as specified
Due 20 May 2017
Resolved 19 May 2017
Resolution: Provided 02 new weak links with proper tags.
Lifesaving › Lifefloat › Serviceable
Issued 20 April 2017 Resolved
Make repair to upper 12 man life float IAW manufactures instructions.
Action required: 705 - Other - as specified
Due 20 May 2017
Resolved 19 May 2017
Resolution: Repaired 12 man life float IAW with manufacture's instructions.
Lifesaving › Lifefloat › Platform
Issued 21 April 2016 Resolved
Clean up/organize primary lifesaving stowage area. Prove all items are float free
Action required: 705 - Other - as specified
Due 28 April 2016
Resolved 28 April 2016
Resolution: Checked lifefloat stowage area. Area all clean and organized, lifefloats installed properly and float free.
Fire Fighting › Ventilation Systems › Ventilation Fire Dampers
Issued 21 April 2016 Resolved
Provide means to secure ventilation to machinery space
Action required: 705 - Other - as specified
Due 28 April 2016
Resolved 28 April 2016
Resolution: Attended vessel and verified there is a means to secure ventilation to the E/R.
Lifesaving › Lifefloat › Serviceable
Issued 12 June 2014 Resolved
Renew 12 man life float. Vsl restricted to max of 30 persons.
Action required: 705 - Other - as specified
Due 12 July 2014
Resolved 15 July 2014
Lifesaving › Lifefloat › Paddle
Issued 12 June 2014 Resolved
Provide 02 oars with vsl name marked on them.
Action required: 705 - Other - as specified
Due 12 July 2014
Resolved 15 July 2014
Lifesaving › Lifejacket/PFD (Type III) › Quantity
Issued 12 June 2014 Resolved
Provide 06 adult life jackets as per COI. Vsl resticted to number of persons with lifejackets.
Action required: 705 - Other - as specified
Due 12 July 2014
Resolved 15 July 2014
Electrical › Electric Generation Source (service) › Generator
Issued 12 September 2008 Resolved
Repair leaking fuel injector port on generator.
Action required: 705 - Other - as specified
Due 30 September 2008
Resolved 30 September 2008
Electrical › Electrical Distribution System (service) › Circuit Breaker
Issued 12 September 2008 Resolved
Provide blank for missing breaker on breaker panel in E/R.
Action required: 705 - Other - as specified
Due 30 September 2008
Resolved 30 September 2008
Fire Fighting › Ventilation Systems › Ducts
Issued 12 September 2008 Resolved
Provide ventilation closure device for E/R ventilation duct.
Action required: 705 - Other - as specified
Due 30 September 2008
Resolved 30 September 2008
Accommodation/Occupational Safety › Medical/First Aid › Medicine Chest
Issued 12 September 2008 Resolved
Replace expired aspirin in first aid kit.
Action required: 705 - Other - as specified
Due 30 September 2008
Resolved 30 September 2008
Documentation › Certificates/Documents › FCC SSL
Issued 12 September 2007 Resolved
Provide original and current FCC Station License.
Action required: 705 - Other - as specified
Due 12 October 2007
Resolved 11 October 2007
Personnel › Certificates/Documents/Licenses › License, Radio Officer
Issued 12 September 2007 Resolved
Provide valid FCC Marine Radio Operator Permit.
Action required: 705 - Other - as specified
Due 12 October 2007
Resolved 11 October 2007
Lifesaving › Lifefloat › Serviceable
Issued 12 September 2007 Resolved
Repair or replace 12-person lifefloat (located portside, top).
Action required: 705 - Other - as specified
Due 12 October 2007
Resolved 11 October 2007
Fire Fighting › Portable Dry Chemical Fire Extinguisher › Number
Issued 12 September 2007 Resolved
Provide additional B-II portable fire extinguisher and smoke detector in galley space, to meet galley grease extraction hood regs and CID Policy Letter #20.
Action required: 705 - Other - as specified
Due 12 October 2007
Resolved 11 October 2007
Fire Fighting › Ventilation Systems › Exhaust Ducts (Galley Ranges)
Issued 12 September 2007 Resolved
Clean grease build-up in galley hood ducting and grease trap.
Action required: 705 - Other - as specified
Due 12 October 2007
Resolved 11 October 2007
Fire Fighting › Grease Extraction Hood › General
Issued 26 May 2006 Resolved
Clean galley hood, duct, and screen.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 26 June 2006
Resolved 26 June 2006
Documentation › Markings/Placards › Lifejacket Placard
Issued 26 May 2006 Resolved
Renew lifejacket instruction placard.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 26 June 2006
Resolved 26 June 2006
Resolution: New placard mounted on-board
Communications › Alarms/Indicators › Bilge Alarm
Issued 26 May 2006 Resolved
Replace #4 bilge alarm light (dim).
Action required: 705 - Other - as specified
Due 26 June 2006
Resolved 26 June 2006
Resolution: Verifed new light installed and operational.
Lifesaving › Lifefloat › Floating Electric Waterlight
Issued 26 May 2006 Resolved
Provide proper support for lifefloat waterlights.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 26 June 2006
Resolved 26 June 2006
Communications › Radio Communications › Radiotelephone Transceiver (2-4 MHz)
Issued 26 May 2006 Resolved
Install MF radio tranceiver/irridium sat phone. MF Transceiver must be capable of 2182, 2638, 2670 kHz & public station frequency in 1710 - 2850 kHz band.
Action required: 705 - Other - as specified
Due 26 June 2006
Resolved 31 October 2006
Resolution: Examined new MF/SSB radio installation and operation. All was satisfactory.
Navigation › Piloting/Steering › Inland Navigation Rules
Issued 26 May 2006 Resolved
Provide updated Inland NAVRULS book.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 26 June 2006
Resolved 26 June 2006
Electrical › Electrical Distribution System (service) › Cable
Issued 28 April 2006 Resolved
Replace shore tie cable (worn, frayed cover & spliced).
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 28 May 2006
Resolved 26 May 2006
Resolution: New shore tie installed.
Navigation › Collision/Grounding Avoidance › Navigation Lights
Issued 28 April 2006 Resolved
Replace (frosted) stern light lens cover .
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 28 May 2006
Resolved 26 May 2006
Resolution: New lens cover found installed.
Accommodation/Occupational Safety › Occupational Safety › Guards for Exposed Hazards
Issued 28 April 2006 Resolved
Prove proper installation of all exhaust lagging and machinery guards. Provide/fax statement attesting to same prior to carrying passengers.
Action required: 701 - Prior to carriage of passengers/cargo
Due 28 April 2006
Resolved 29 April 2006
Resolution: Faxed statement from operator/master rcvd by CG inspections, including pictures; in-person follow-up by CG MI confirmed installation.
Engineering › Fuel Oil Service System › Hose
Issued 28 April 2006 Resolved
Provide evidence flexible fuel hoses meet SAE-J1942 standard, or replace with hoses that meet standard.
Action required: 705 - Other - as specified
Due 28 May 2006
Resolved 26 May 2006
Resolution: Specifications hoses met standards provided to inspector during annual examination.
Engineering › Fuel Oil Service System › Piping
Issued 15 June 2005 Resolved
Replace or fix fuel return line in engine room.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 17 June 2005
Resolved 15 June 2005
Electrical › Electric Generation Source (service)
Issued 15 June 2004 Resolved
Clean generator windings IAW 46CFR183.200 LEGACY COMPONENT DESC: Power Requirement
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 29 June 2004
Resolved 16 June 2004
Resolution: Entered in error.
Engineering › Generator (propulsion-electric) › Winding
Issued 15 June 2004 Resolved
Clean generator windings IAW 46CFR183.200
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 29 June 2004
Resolved 28 June 2004
Engineering › Diesel Engine (propulsion-direct drive) › Air Cleaner
Issued 15 June 2004 Resolved
Clean power therm air filters on both mde's IAW 46CFR176.800
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 29 June 2004
Resolved 28 June 2004
Stability › Watertight Integrity › General
Issued 15 June 2004 Resolved
Remove old fuel line and plug holes in watertight bulkheads left by deterorating copper line IAW 46CFR176.800
Condition: Design Flaw
Action required: 705 - Other - as specified
Due 29 June 2004
Resolved 28 June 2004
Engineering › Diesel Engine (propulsion-direct drive) › Piping (exhaust)
Issued 15 June 2004 Resolved
Repair minor salt water leak on stbd exhaust IAW 46CFR182.430
Condition: Damaged By Earlier Event
Action required: 705 - Other - as specified
Due 29 June 2004
Resolved 28 June 2004
Communications › Alarms/Indicators › Rate of Turn Indicator
Issued 15 June 2004 Resolved
Replace starboard tachometer and starboard marine gear oil pressure gauge IAW 46CFR182.410(b)
Condition: Damaged By Earlier Event
Action required: 705 - Other - as specified
Due 29 June 2004
Resolved 28 June 2004
Lifesaving › Buoyant Apparatus
Issued 2 September 2003 Resolved
Renew deteriorated poly lines IWO life float painter lines, hand hold lines, and basket retaining lines.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 11 September 2003
Resolution: New lines were satisfactorily installed.
Electrical › Lighting (service)
Issued 2 September 2003 Resolved
Provide covers for flourescent lights in the galley. LEGACY COMPONENT DESC: Lighting Fixture
Condition: Improper Installation
Due 1 October 2003
Resolved 31 October 2003
Resolution: Covers properly installed.
Lifesaving › Lifejacket/PFD (Type I)
Issued 2 September 2003 Resolved
Renew retro reflective material on lifejackets as necessary. LEGACY COMPONENT DESC: Retroreflective Material
Condition: Improper/Lack of Maintenance
Due 1 October 2003
Resolved 5 September 2003
Stability › Weathertight Integrity
Issued 2 September 2003 Resolved
Renew broken window IWO galley, starboard side, aft window.
Condition: Unknown
Due 1 October 2003
Resolved 31 October 2003
Resolution: Inspected new window.
Personnel › Training
Issued 2 September 2003 Resolved
Prove crew proficiency during drills. Crew not onboard for inspection. They were attending STCW training. LEGACY COMPONENT DESC: Fire Fighting Basic
Due 1 October 2003
Resolved 31 October 2003
Resolution: Crew drills logged
Documentation › Certificates/Documents
Issued 2 September 2003 Resolved
Provide current COD. NVDC stated COD has been paid for and issued to the wrong address. LEGACY COMPONENT DESC: Certificate of Documentation (CG-1270)
Condition: Unknown
Due 1 October 2003
Resolved 31 October 2003
Resolution: Reviewed current documentation.
Engineering › Sea-water System (primary cooling)
Issued 2 September 2003 Resolved
Provide double hose clamps for engine salt water hoses. LEGACY COMPONENT DESC: Piping
Due 1 November 2003
Resolved 31 October 2003
Resolution: All salt water supply hoses double clamped.
Electrical › Electric Supply System (service)
Issued 2 September 2003 Resolved
Properly hard wire battery chargers to breakers. LEGACY COMPONENT DESC: Battery Charger
Due 1 October 2003
Resolved 31 October 2003
Resolution: Inspected satisfactory wiring of battery chargers
Construction/Loadline › Penetrations
Issued 11 September 2002 Resolved
Make collision bulkhead watertight. IAW 46 CFR 185.610
Condition: Unknown
Due 17 October 2002
Resolved 3 October 2002
Electrical › Lighting (service)
Issued 11 September 2002 Resolved
Install cover on electrical J-box in wheelhouse. IAW 46 CFR 183.330 LEGACY COMPONENT DESC: Outlet Box
Condition: Unknown
Due 17 October 2002
Resolved 3 October 2002
Electrical › Lighting (service)
Issued 11 September 2002 Resolved
Remove or use dead ended wires in forward compartment and starboard side engineroom. IAW 46 CFR 183.340 LEGACY COMPONENT DESC: Lighting Feeder
Due 17 October 2002
Resolved 3 October 2002
Electrical › Electric Generation Source (service)
Issued 11 September 2002 Resolved
Clean generator windings. IAW 46 CFR 176.830
Due 17 October 2002
Resolved 3 October 2002
Electrical › Electric Generation Source (service)
Issued 11 September 2002 Resolved
Install guard over generator belts. IAW 46 CFR 176.830
Due 17 October 2002
Resolved 3 October 2002
Electrical › Electrical Distribution System (service)
Issued 11 September 2002 Resolved
Install metallic wire guards at 24 inch intervals. IAW 46 CFR 183.340
Due 17 October 2002
Resolved 3 October 2002
Electrical
Issued 19 June 2001 Resolved
Permanently wire battery chargers into electrical box in battery room.
Condition: Unknown
Due 19 June 2001
Resolved 19 June 2001
Engineering
Issued 19 June 2001 Resolved
DOUBLE CLAMP RW HOSES ON BOTH MDEs.
Condition: Unknown
Due 19 June 2001
Resolved 19 June 2001
Engineering
Issued 19 June 2001 Resolved
Properly mount fresh water pump near distribution panel in ER.
Condition: Unknown
Due 19 June 2001
Resolved 19 June 2001
Electrical
Issued 19 June 2001 Resolved
REDO CONNECTIONS TO ANCHOR WINDLASS CONTROL IN THE BATTERY ROOM.
Condition: Unknown
Due 19 June 2001
Resolved 19 June 2001
Construction/Loadline
Issued 19 June 2001 Resolved
SEAL WT BUL;KHEAD AFT IN BATTERY ROOM.
Condition: Unknown
Due 19 June 2001
Resolved 19 June 2001
Accommodation/Occupational Safety
Issued 19 June 2001 Resolved
INSTALL LOCKING DEVICE ON MSD OVERBOARD VALVE.
Condition: Unknown
Due 19 June 2001
Resolved 19 June 2001
Electrical
Issued 19 June 2001 Resolved
MARK PANEL BREAKERS IN PILOTHOUSE.
Condition: Unknown
Due 19 June 2001
Resolved 19 June 2001
Engineering
Issued 19 June 2001 Resolved
ATTACH RAW WATER SUPPLY VALVE HANDLES TO VALVE STEMS FOR BOTH MDEs.
Condition: Unknown
Due 19 June 2001
Resolved 19 June 2001
Electrical
Issued 19 June 2001 Resolved
MARK CIRCUIT BREAKER IN ENGINEROOM PANEL.
Condition: Unknown
Due 19 June 2001
Resolved 19 June 2001
Construction/Loadline
Issued 19 June 2001 Resolved
INSTALL BILGE ALARM SYSTEM IAW [name withheld] 46CFR 182.530 WITH A LIGHT AND APLPLICABLE ALARM FOR EACH COMPARTMENT.
Condition: Unknown
Due 19 June 2001
Resolved 19 June 2001
Construction/Loadline
Issued 14 February 2001 Resolved
Provide damage control kit.
Condition: Unknown
Due 15 February 2001
Resolved 13 July 2001
Construction/Loadline
Issued 14 February 2001 Resolved
provide metallic valves and penetrations for PVC piping traversing watertight bulkheads.
Condition: Unknown
Due 1 February 2002
Resolved 17 September 2002
Navigation
Issued 20 June 2000 Resolved
Update charts.
Condition: Unknown
Due 6 July 2000
Resolved 6 July 2000
Navigation
Issued 20 June 2000 Resolved
Provide light for compass.
Condition: Unknown
Due 6 July 2000
Resolved 6 July 2000
Lifesaving
Issued 20 June 2000 Resolved
Properly label PFD stowage placards.
Condition: Unknown
Due 6 July 2000
Resolved 6 July 2000
Engineering
Issued 20 June 2000 Resolved
Install light guards on engine room lighting system.
Condition: Unknown
Due 6 July 2000
Resolved 6 July 2000
Lifesaving
Issued 20 June 2000 Resolved
Provide (15) additional adult PFDs and (1) child size PFD.
Condition: Unknown
Due 6 July 2000
Resolved 6 July 2000
Lifesaving
Issued 20 June 2000 Resolved
Provide water light for (6) man life float.
Condition: Unknown
Due 6 July 2000
Resolved 6 July 2000
Navigation
Issued 20 June 2000 Resolved
Double nut steering linkages.
Condition: Unknown
Due 20 June 2000
Resolved 20 June 2000
Engineering
Issued 22 June 1999 Resolved
Label Remote F/O Shut Down Valves.
Condition: Unknown
Due 1 July 1999
Resolved 6 July 1999
Engineering
Issued 22 June 1999 Resolved
Fix F/O Leak on Port MDE.
Condition: Unknown
Due 1 July 1999
Resolved 6 July 1999
Navigation
Issued 22 June 1999 Resolved
Install Locking Pins on Stering System or Double Nut Assembly.
Condition: Unknown
Due 1 July 1999
Resolved 6 July 1999
Fire Fighting
Issued 22 June 1999 Resolved
Seal Aft E/R Bulkhead for Fixed Fire System. IAW 46CFR
Condition: Unknown
Due 1 July 1999
Resolved 6 July 1999
Fire Fighting
Issued 22 June 1999 Resolved
Post Instructions at Control Station for Fixed System. IAW46CFR 185.612.
Condition: Unknown
Due 1 July 1999
Resolved 6 July 1999
Electrical
Issued 22 June 1999 Resolved
Fix shut down on Ship Service Generator which allows Shut Down in the eventof E/R Fire. IAW 46CFR182.465.
Condition: Unknown
Due 1 July 1999
Resolved 6 July 1999
Fire Fighting
Issued 22 June 1999 Resolved
Provide Closure for Natural Vent Intake to E/R for Fixed Fire System. IAW 46CFR 182.465.
Condition: Unknown
Due 1 July 1999
Resolved 6 July 1999
Electrical
Issued 22 June 1999 Resolved
Repair Anchor Light.
Condition: Unknown
Due 1 July 1999
Resolved 6 July 1999
Lifesaving
Issued 18 March 1999 Resolved
EPIRB test not logged IAW 46 CFR 185.728
Condition: Unknown
Due 15 April 1999
Resolved 10 May 1999
Lifesaving
Issued 18 March 1999 Resolved
Drills not conducted with vessels crew members and loged IAW 46CFR 185.420/.520/.524. Required master to conduct drills and log training prior to sailing with passengers.
Condition: Unknown
Due 15 April 1999
Resolved 10 May 1999
Lifesaving
Issued 18 March 1999 Resolved
Flooding alarms not installed on vessel IAW 46 CFR 182.530
Condition: Unknown
Due 15 May 1999
Resolved 8 July 1999
Navigation
Issued 18 March 1999 Resolved
Current Tide table not onboard vessel IAW 46 CFR 184.420
Condition: Unknown
Due 15 April 1999
Resolved 10 May 1999
Documentation
Issued 18 March 1999 Resolved
Master license not on board vessel IAW 46 CFR 185.402, master shall ensure orginal is brought to USCG Marine Safety Office San Diego, California before operating with passengers.
Condition: Unknown
Due 15 April 1999
Resolved 10 May 1999
Lifesaving
Issued 9 November 1998 Resolved
TWO (2) WATER LIGHTS NOT WORKING (ONE LOCATED IN THE CABIN, ONE LOCATED ON TOP OF THE MAIN CABIN)
Condition: Unknown
Due 12 November 1998
Resolved 13 November 1998
Navigation
Issued 9 November 1998 Resolved
NO CHARTS ON BOARD VESSEL
Condition: Unknown
Due 12 November 1998
Resolved 13 November 1998
Lifesaving
Issued 9 November 1998 Resolved
UNAPPROVED LIFE LINE ATTACHED TO WATER LIGHT
Condition: Unknown
Due 12 November 1998
Resolved 13 November 1998
Lifesaving
Issued 9 November 1998 Resolved
MISSING VESSELS NAME ON LIFE RING IN CABIN/BRIDGE
Condition: Unknown
Due 12 November 1998
Resolved 13 November 1998
Electrical
Issued 1 June 1998 Resolved
REMOVE DEAD END WIRING IN ENGINE ROOM AND FWD STORAGE OR END IN J-BOX.
Condition: Unknown
Due 16 July 1998
Resolved 27 July 1998
Electrical
Issued 1 June 1998 Resolved
BAND ALL HANGING CABLING WITH METALLIC SUPPORTS AND PROVIDE CHAFFING GEAR IN E/R AND FWD STOWAGE.
Condition: Unknown
Due 16 July 1998
Resolved 27 July 1998
Electrical
Issued 1 June 1998 Resolved
PROVIDE COVER FOR BATTERIES IN E/R.
Condition: Unknown
Due 16 July 1998
Resolved 27 July 1998
Construction/Loadline
Issued 1 June 1998 Resolved
REPLACE AFT STBD CLEAT.
Condition: Unknown
Due 16 July 1998
Resolved 27 July 1998
Navigation
Issued 1 June 1998 Resolved
PROVIDE UP-TO-DATE CHARTS, LIGHT LIST/TIDE/CURRENTS FOR INTENDED VOYAGES.
Condition: Unknown
Due 15 July 1998
Resolved 15 July 1998
Electrical
Issued 1 June 1998 Resolved
PROVIDE SWITCHBOARD LABEL DESIGNATIONS FOR E/R SWITCHBOARD.
Condition: Unknown
Due 16 July 1998
Resolved 27 July 1998
Lifesaving
Issued 1 June 1998 Resolved
PROVIDE PLACARDS INDICATING LOCATION OF ADULT AND CHILD LIFEJACKETS IN GALLEY.
Condition: Unknown
Due 16 July 1998
Resolved 27 July 1998
Engineering
Issued 1 June 1998 Resolved
REPAIR PORT AND STBD FUEL FILTER LEAKS.
Condition: Unknown
Due 16 July 1998
Resolved 27 July 1998
Fire Fighting
Issued 1 June 1998 Resolved
Conduct and log man o/b, fire, and abandon ship drills and EPIRB check.
Condition: Unknown
Due 1 June 1998
Resolved 13 July 1998
Lifesaving
Issued 1 June 1998 Resolved
PROVIDE EMERGENCY BROADCAST PLACARD.
Condition: Unknown
Due 16 July 1998
Resolved 27 July 1998
Lifesaving
Issued 1 June 1998 Resolved
PROVIDE 3 CHILDS LIFEJACKETS (ADDITIONAL).
Condition: Unknown
Due 15 July 1998
Resolved 15 July 1998
Lifesaving
Issued 1 June 1998 Resolved
PROVIDE NEW HYDROSTATIC RELEASE/BATTERY CHECK/ REGISTRATION FOR EPIRB.
Condition: Unknown
Due 15 July 1998
Resolved 15 July 1998
Fire Fighting
Issued 18 June 1997 Resolved
Mount and service all hand hewld fire extinguishers._x001C_ _x001C_ _x001C_ _x001C_
Condition: Unknown
Due 18 June 1997
Resolved 27 June 1997
Lifesaving
Issued 18 June 1997 Resolved
Perform satisfactory stability test for 46 passengers and 6 crewmembers._x001C_ _x001C_ _x001C_ _x001C_
Condition: Unknown
Due 24 June 1997
Resolved 25 June 1997
Lifesaving
Issued 18 June 1997 Resolved
Stencil flare container with half inch letters "Distress Signals" _x001C_ _x001C_ _x001C_ _x001C_
Condition: Unknown
Due 27 June 1997
Resolved 27 June 1997
Engineering
Issued 18 June 1997 Resolved
Properly mount fuel shut off valves._x001C_ _x001C_ _x001C_ _x001C_
Condition: Unknown
Due 18 June 1997
Resolved 27 June 1997
Electrical
Issued 18 June 1997 Resolved
provide blueprints of electrical installation._x001C_ _x001C_ _x001C_ _x001C_
Condition: Unknown
Due 18 June 1997
Resolved 18 June 1997
Construction/Loadline
Issued 18 June 1997 Resolved
Install bilge high level alarm as required by 46CFR182.530._x001C_ _x001C_ _x001C_ _x001C_
Condition: Unknown
Due 18 June 1997
Resolved 18 June 1997
Lifesaving
Issued 18 June 1997 Resolved
Mount the required ring buoy near the pilot house with light and line attached._x001C_ _x001C_ _x001C_
Condition: Unknown
Due 18 June 1997
Resolved 27 June 1997
Documentation
Issued 18 June 1997 Resolved
Provide FCC certificates and licenses, emergency broadcast placard as reqiired by 46CFR184.506.
Condition: Unknown
Due 18 June 1997
Resolved 27 June 1997
Navigation
Issued 18 June 1997 Resolved
Demonstrate navigation lights._x001C_ _x001C_ _x001C_ _x001C_
Condition: Unknown
Due 18 June 1997
Resolved 25 June 1997
Unknown
Issued 18 June 1997 Resolved
Present vessel for operational check of propulsion, steering, electrical, comms, signaling and drills._x001C_ _x001C_ _x001C_
Condition: Unknown
Due 18 June 1997
Resolved 25 June 1997
Fire Fighting
Issued 18 June 1997 Resolved
Install fixed CO2 system as well as a detection system as required in 46 CFR 181.400._x001C_ _x001C_ _x001C_
Condition: Unknown
Due 18 June 1997
Resolved 18 June 1997
Lifesaving
Issued 18 June 1997 Resolved
Provide sufficient life floats and correct weak links for floats, mounted on top of the cabin._x001C_ _x001C_ _x001C_
Condition: Unknown
Due 18 June 1997
Resolved 25 June 1997
Lifesaving
Issued 18 June 1997 Resolved
Provide stencils and stowage for all life preservers._x001C_ _x001C_ _x001C_ _x001C_
Condition: Unknown
Due 18 June 1997
Resolved 25 June 1997
Construction/Loadline
Issued 16 August 1996 Resolved
CONDUCT AN UNDERWAY TEST IN THE PRESENCE OF A MARINE INSPECTOR.
Condition: Unknown
Due 16 August 1996
Resolved 16 August 1996
Documentation
Issued 17 February 1995 Resolved
PROVIDE PROOF OF VALID FCC OPERATOR'S LICENSE PRIOR TO THE CARRIAGE OF PASSENGERS.
Condition: Unknown
Due 1 March 1995
Resolved 1 March 1995
Lifesaving
Issued 18 February 1994 Resolved
[withheld — contains personal information; the deficiency system, dates, and resolution status are shown above]
Condition: Unknown
Due 18 February 1994
Resolved 18 February 1994
Lifesaving
Issued 18 February 1994 Resolved
REPLACE LIFE RING.
Condition: Unknown
Due 18 February 1994
Resolved 18 February 1994
Fire Fighting
Issued 12 April 1989 Resolved
HYDROSTATICALLY TEST ONE (1) B-I FIRE EXTINGUISHER.
Condition: Unknown
Due 12 April 1989
Resolved 12 April 1989
Construction/Loadline
Issued 12 April 1989 Resolved
MAKE PERMANENT REPAIRS TO THE COLLISION BULKHEAD ENSURING THAT THE LOWEST EDGE OF THE OPENING DOES NOT EXCEED MORE THAN 12" BELOW THE BULKHEAD DECK.
Condition: Unknown
Due 12 April 1989
Resolved 12 April 1989
Lifesaving
Issued 12 April 1989 Resolved
PROVIDE ONE (1) FLOAT FREE LINK.
Condition: Unknown
Due 12 April 1989
Resolved 12 April 1989
Lifesaving
Issued 12 April 1989 Resolved
PROVIDE ONE (1) RED DAY FLARE.
Condition: Unknown
Due 12 April 1989
Resolved 12 April 1989
Fire Fighting
Issued 17 April 1986 Resolved
SERVICE THE B-II HAND PORTABLE FIRE EXTINGUISHER TO PROVIDE THE REQUIRED NUMBER FOR THE ENGINE SPACE PRIOR TO CARRYING PASSENGERS FOR HIRE.
Condition: Unknown
Due 17 April 1986
Resolved 17 April 1986
Engineering
Issued 17 April 1986 Resolved
RENEW THE GROUNDING STRIP AND HOSE CONNECTION AT THE PORT ENGINE ROOM FUEL TANK VENT PIPE.
Condition: Unknown
Due 17 April 1986
Resolved 17 April 1986
Electrical
Issued 17 April 1986 Resolved
RENEW THE WASTED FEEDER CABLES FROM THE STARBOARD BATTERIES IN WAY OF THE ENGINE MOUNTINGS PRIOR TO CARRYING PASSENGERS FOR HIRE.
Condition: Unknown
Due 17 April 1986
Resolved 17 April 1986
Lifesaving
Issued 17 April 1986 Resolved
PROVIDE SIX ORANGE AND SIX RED FLARES IN PLACE OF EXPIRED FLARES CURRENTLY ABOARD PRIOR TO CARRYING PASSENGERS FOR HIRE.
Condition: Unknown
Due 17 April 1986
Resolved 17 April 1986
Lifesaving
Issued 17 April 1986 Resolved
PROVIDE NEW SEA PAINTERS FOR BOTH REQUIRED LIFE FLOATS PRIOR TO CARRYING PASSENGERS FOR HIRE.
Condition: Unknown
Due 17 April 1986
Resolved 17 April 1986

Casualty record · 1

15 June 2018Routine · role: Involved in a Marine Casualty · activity 6445300
Each line is an incident investigation the Coast Guard recorded with this hull among the vessels involved, with the date and the classification the Coast Guard gave it, and the bridge, lock or dam the investigation names where it names one. Involvement is not fault. The investigation narrative is not published. Source: IIR, through 2026.

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.