Records from 2016 to 2026. Most recent: inspection, 27 May 2026.
Everything above is free. The detail below — the inspection history, the deficiency record and the documentation record — is Professional, $39 a month. Sign in.
Inspection history · 17
27 May 2026
Annual Inspection
Physical examination · Marine Safety Unit Lewes · USCG East District (CGD-E) · Activity 8395549
27 May 2025
Annual Inspection · Deficiency Check
Physical examination · Marine Safety Unit Lewes · USCG East District (CGD-E) · Activity 8146293
28 January 2025
Hull Examination · Internal Structural Exam
Physical examination · Marine Safety Unit Lewes · USCG East District (CGD-E) · Activity 8066861
3 June 2024
Annual Inspection
Physical examination · Marine Safety Unit Lewes · USCG East District (CGD-E) · Activity 7923970
15 May 2023
Deficiency Check · Annual Inspection
Physical examination · Marine Safety Unit Lewes · USCG East District (CGD-E) · Activity 7684433
17 January 2023
Internal Structural Exam · Hull Examination
Physical examination · Marine Safety Unit Lewes · USCG East District (CGD-E) · Activity 7623729
9 May 2022
Deficiency Check · COI Inspection
Physical examination · Marine Safety Unit Lewes · USCG East District (CGD-E) · Activity 7443760
13 May 2021
Annual Inspection
Physical examination · Marine Safety Unit Lewes · USCG East District (CGD-E) · Activity 7195769
20 January 2021
Hull Examination · Internal Structural Exam
Physical examination · Marine Safety Unit Lewes · USCG East District (CGD-E) · Activity 7126641
21 May 2020
Annual Inspection
Physical examination · Marine Safety Unit Lewes · USCG East District (CGD-E) · Activity 6956584
8 May 2019
Annual Inspection
Physical examination · Marine Safety Unit Lewes · USCG East District (CGD-E) · Activity 6678515
28 January 2019
Hull Examination · Deficiency Check · Internal Structural Exam
Physical examination · Marine Safety Unit Lewes · USCG East District (CGD-E) · Activity 6615807
15 November 2018
In-Service Inspection
Physical examination · Marine Safety Unit Lewes · USCG East District (CGD-E) · Activity 6581262
7 May 2018
Annual Inspection
Physical examination · Marine Safety Unit Lewes · USCG East District (CGD-E) · Activity 6507936
10 May 2017
Deficiency Check · COI Inspection · DAPI Audit
Physical examination · Marine Safety Unit Lewes · USCG East District (CGD-E) · Activity 6141946
18 January 2017
Internal Structural Exam · Drydock Exam
Physical examination · Marine Safety Unit Lewes · USCG East District (CGD-E) · Activity 6072504
26 May 2016
Annual Inspection · DAPI Audit
Physical examination · Marine Safety Unit Lewes · USCG East District (CGD-E) · Activity 5887502
07 - Fire Safety › N/A - No Subsystem › Oil accumulation in engine room
Issued 27 May 2025
Resolved
The bilges and other spaces have no excessive accumulation oil that might create a fire hazard. Vessel's port main engine had extensive oil leak in the vicinity of the engine exhaust manifold. Identify cause of leak, repair and clean up excessive oil on engine, battery switch and bilges.
Condition: Damaged By Earlier Event
Action required: 701 - Prior to carriage of passengers/cargo
Due 3 June 2025
Resolved 30 May 2025
Resolution: Owner/operator cleaned up residual oil and fastened a new clamp on oil return hose.
01 - Certificates & Documentation › 013 - Documents › Signs, indications
Issued 27 May 2025
Resolved
Placards containing instructions for the donning and use of the lifejackets must be posted in conspicuous places. Vessel had two style of PFD and instructions for one PFD type only. Post donning instructions for both type PFD's.
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 10 June 2025
Resolved 30 May 2025
Resolution: Owner posted proper lifejacket donning instructions for both styles of PFD's.
11 - Life Saving Appliances › N/A - No Subsystem › Distress flares
Issued 27 May 2025
Resolved
A vessel on a lakes, bays and sounds route must carry 03 red flares and 03 orange smoke distress signals. Vessel had 03 expired red flares. Ensure vessel is provided with 03 additional red flares/orange smoke prior to carrying passengers.
Condition: Improper Installation
Action required: 701 - Prior to carriage of passengers/cargo
Due 3 June 2025
Resolved 30 May 2025
Resolution: Owner/operator provided non expired flares.
11 - Life Saving Appliances › N/A - No Subsystem › Rigid liferafts
Issued 27 May 2025
Resolved
Each item of survival craft equipment must be of good quality and efficient for the purpose it is intended to serve. Life float lights batteries were expired and retro tape was faded. Ensure batteries are proper non expired type and retro tape provides adequate reflection.
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 8 July 2025
Resolved 30 May 2025
Resolution: Owner/operator provided proper non expired battery and satisfactory retro.
04 - Emergency Systems › N/A - No Subsystem › Water level indicator
Issued 15 May 2023
Resolved
Vessel's greater than 26' in length must have a visual and audible alarm at the operating station to indicate high water level in the machinery space. Vessel's visual indicator for the #4 high water alarm in the engine compartment was not operating properly. Ensure proper operation of the visual indicator.
Condition: Damaged By Earlier Event
Action required: 16 - Rectify deficiencies w/in 14 days
Due 29 May 2023
Resolved 9 June 2023
Resolution: Owner installed new visual high water alarm. Alarm tested satisfactorily.
07 - Fire Safety › N/A - No Subsystem › Fire pumps and its pipes
Issued 15 May 2023
Resolved
All piping, valves, and fittings shall be in accordance with good marine practice and suitable for the purpose intended. Fire main piping was leaking water in the vicinity of the overboard discharge valve. Ensure fire main piping is no longer leaking in the vicinity of the overboard dicharge valve.
Condition: Damaged By Earlier Event
Action required: 16 - Rectify deficiencies w/in 14 days
Due 29 May 2023
Resolved 9 June 2023
Resolution: Owner repaired leaking fire main valve. Valve tested and no longer leaking water.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 15 May 2023
Resolved
Equipment mounted on a hinged door of an enclosure shall be shielded to from accidental contact by a person with the door open and circuit energized. Circuit breaker panel had openings to live circuits ensure a proper breaker or blank is installed.
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 29 May 2023
Resolved 9 June 2023
Resolution: Owner installed blanks in breaker box.
11 - Life Saving Appliances › N/A - No Subsystem › Operational readiness of lifesaving appliances
Issued 15 May 2023
Resolved
The float free link required by 180.130(a)(1) must be certified to meet 46 CFR 160.073 (Sub Q) and be of the proper strength and size for the life float indicated on the it's identification tag. Owner/operator could not provide weak link ID tag. Provide evidence that the weak link has an ID tag and that it is of suitable size and strength for life float.
Condition: Invalid
Action required: 16 - Rectify deficiencies w/in 14 days
Due 29 May 2023
Resolved 9 June 2023
Resolution: Owner installed two new valid weak links.
01 - Certificates & Documentation › 011 - Ships Certificates › Other (certificates)
Issued 15 May 2023
Resolved
[withheld — contains personal information; the deficiency system, dates, and resolution status are shown above]
Condition: Invalid
Action required: 16 - Rectify deficiencies w/in 14 days
Due 29 May 2023
Resolved 9 June 2023
Resolution: Owner provided new valid FCC Station License and Safety certificates.
09 - Working and Living Conditions › 092 - Working Conditions › Other (accident prevention)
Issued 9 May 2022
Resolved
No marine employer shall emply an individual to serve as a crewmember unless the individueal passes a chemical test for dangeroud drugs. Present crewmember is listed as "testing not conducted". 46CFR16.210
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 23 May 2022
Resolved 22 July 2022
Resolution: MI received and reviewed confirmation of enrollment for all licensed and unlicensed crew. Crew marked as "full compliance" until 6/30/2023.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 9 May 2022
Resolved
An adult life jacket must be carried for each person on board. Vessel has a total of 85 servicable adult life jackets on board. Vessel limited to 82 passengers until 03 servicable life jackets are placed on board to the satisfaction of the attending marine inspector. 46CFR180.71
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 9 May 2022
Resolved 10 May 2022
Resolution: New life jackets were installed on board the vessel.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 9 May 2022
Resolved
A vessel of at least 26' in length must be provided with individual bilge lines and suction for each watertight compartment. The vessel was not able to provide suction to the bilge piping system for the lazerette. Prior to carrying passengers demonstrate bilge piping can provide adequate suction to the lazerette to the satisfaction of the attending marine inspector. 46CFR182.510
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 9 May 2022
Resolved 10 May 2022
Resolution: A new bilge pump was installed and provided adequate suction.
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 13 May 2021
Resolved
The power fire pump shall be self priming and of such size as to discharge an effective stream from a hose. This pump may also be connected to the bilge system as described in 46 CFR 182.25, 46 CFR 181.10
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Due 13 May 2021
Resolved 13 May 2021
Resolution: Replacement pump impeller installed. Witnessed operation, all sat.
11 - Life Saving Appliances › N/A - No Subsystem › Stowage and provision of liferafts
Issued 13 May 2021
Resolved
The water light of an approved automatic electric type, constructed in accordance with 161.010. Marine Inspector discovered the vessel's three water lights did not operate or did not have the correct battery installed. Ensure proper installation prior to carrying passengers at night or during periods of limited visibility. 46 CFR 180.15-5 (d)
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Due 13 May 2021
Resolved 13 May 2021
Resolution: Proper batteries installed. Marine Inspector witnessed installation and working condition of water lights.
11 - Life Saving Appliances › N/A - No Subsystem › Distress flares
Issued 13 May 2021
Resolved
Six hand red flare distress signals approved in accordance with 46 CFR 160.021 in subchapter Q of this chapter. Marine Inspector observed the vessel has four valid red flares. Place six valid red flares on board prior to carrying passengers.
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Due 26 May 2021
Resolved 13 May 2021
Resolution: O/O purchased two replacement red flares and placed in service on vessel. All sat.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 13 May 2021
Resolved
Class II and III pressure vessels that have a net internal volume of less than 0.14 cubic meters (5 cubic feet) and do not contain hazardous materials must be stamped with either the ASME "U" or "UM" symbol. The vessel's air receiver does not have the proper approval stamp.
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 12 June 2021
Resolved 18 May 2021
Resolution: Marine Inspector verified pressure vessel meeting standard in 46 CFR 54.01-5 to be installed and fully operable. All sat.
Accommodation/Occupational Safety › Occupational Safety › Deck Rail
Issued 10 May 2017
Resolved
Secure upper deck STBD rail.
Action required: 705 - Other - as specified
Due 15 May 2017
Resolved 15 May 2017
Resolution: Verified rail was tightened and secured.
Lifesaving › Lifefloat › Floating Electric Waterlight
Issued 10 May 2017
Resolved
Provide new batteries for ring buoys/lifefloat lights.
Action required: 705 - Other - as specified
Due 15 May 2017
Resolved 15 May 2017
Resolution: New batteries are provided.
Documentation › Markings/Placards › Capacity Marking
Issued 10 May 2017
Resolved
Provide signage for toal number of passengers alllow on the upper deck.
Action required: 705 - Other - as specified
Due 15 May 2017
Resolved 15 May 2017
Resolution: Marking for upper deck pax limit is posted.
Lifesaving › Lifefloat › Retroreflective Material
Issued 10 May 2017
Resolved
Provide retro-flective tape on lifefloat.
Action required: 705 - Other - as specified
Due 15 May 2017
Resolved 15 May 2017
Resolution: New retroreflective tape is affixed.
Engineering › Fuel Oil Service System › Piping
Issued 10 May 2017
Resolved
Provide bonding wire for fuel tank fill piping.
Action required: 705 - Other - as specified
Due 15 May 2017
Resolved 15 May 2017
Resolution: Bonding wire is installed for both fuel fill hoses.
Accommodation/Occupational Safety › Occupational Safety › Guards for Exposed Hazards
Issued 10 May 2017
Resolved
Provide belt guard on STBD M/E alternator.
Action required: 705 - Other - as specified
Due 15 May 2017
Resolved 15 May 2017
Resolution: Belt guard is installed.
Lifesaving › Lifejacket/PFD (Type I) › Condition
Issued 10 May 2017
Resolved
Provide 23 adult lifejackets. Vessel is restricted to 64 passengers.
Action required: 705 - Other - as specified
Due 15 May 2017
Resolved 15 May 2017
Resolution: Required amount of lifejackets are now provided onboard.