Records from 1985 to 2026. Most recent: inspection, 27 May 2026.
A report is not offered for this hull: Its record holds only 2 of the seven kinds of material a report is built from: inspections, deficiencies, operational controls, tow-unit appearances, casualty records, dimensions and documentation. That is a statement about the record, not about the vessel. Reports.
Inspection history · 70
27 May 2026
Annual Inspection
Physical examination · Marine Safety Unit Lewes · USCG East District (CGD-E) · Activity 8395549
27 May 2025
Annual Inspection · Deficiency Check
Physical examination · Marine Safety Unit Lewes · USCG East District (CGD-E) · Activity 8146293
28 January 2025
Hull Examination · Internal Structural Exam
Physical examination · Marine Safety Unit Lewes · USCG East District (CGD-E) · Activity 8066861
3 June 2024
Annual Inspection
Physical examination · Marine Safety Unit Lewes · USCG East District (CGD-E) · Activity 7923970
15 May 2023
Deficiency Check · Annual Inspection
Physical examination · Marine Safety Unit Lewes · USCG East District (CGD-E) · Activity 7684433
17 January 2023
Internal Structural Exam · Hull Examination
Physical examination · Marine Safety Unit Lewes · USCG East District (CGD-E) · Activity 7623729
9 May 2022
Deficiency Check · COI Inspection
Physical examination · Marine Safety Unit Lewes · USCG East District (CGD-E) · Activity 7443760
13 May 2021
Annual Inspection
Physical examination · Marine Safety Unit Lewes · USCG East District (CGD-E) · Activity 7195769
20 January 2021
Hull Examination · Internal Structural Exam
Physical examination · Marine Safety Unit Lewes · USCG East District (CGD-E) · Activity 7126641
21 May 2020
Annual Inspection
Physical examination · Marine Safety Unit Lewes · USCG East District (CGD-E) · Activity 6956584
8 May 2019
Annual Inspection
Physical examination · Marine Safety Unit Lewes · USCG East District (CGD-E) · Activity 6678515
28 January 2019
Hull Examination · Deficiency Check · Internal Structural Exam
Physical examination · Marine Safety Unit Lewes · USCG East District (CGD-E) · Activity 6615807
15 November 2018
In-Service Inspection
Physical examination · Marine Safety Unit Lewes · USCG East District (CGD-E) · Activity 6581262
7 May 2018
Annual Inspection
Physical examination · Marine Safety Unit Lewes · USCG East District (CGD-E) · Activity 6507936
10 May 2017
Deficiency Check · COI Inspection · DAPI Audit
Physical examination · Marine Safety Unit Lewes · USCG East District (CGD-E) · Activity 6141946
18 January 2017
Internal Structural Exam · Drydock Exam
Physical examination · Marine Safety Unit Lewes · USCG East District (CGD-E) · Activity 6072504
26 May 2016
Annual Inspection · DAPI Audit
Physical examination · Marine Safety Unit Lewes · USCG East District (CGD-E) · Activity 5887502
22 July 2015
Internal Structural Exam · Hull Examination
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 5157891
8 May 2014
DAPI Audit · Annual Inspection
Physical examination · Marine Safety Unit Lewes · USCG East District (CGD-E) · Activity 4853139
15 May 2012
Deficiency Check · Administrative Inspection · COI Inspection · DAPI Audit
Physical examination · Marine Safety Unit Lewes · USCG East District (CGD-E) · Activity 4267617
13 July 2011
Plan Review "T" Boat · Administrative Inspection · Deficiency Check
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 4080024
8 November 2010
Annual Inspection · Administrative Inspection · Hull Examination
Physical examination · Marine Safety Unit Lewes · USCG East District (CGD-E) · Activity 3894936
22 July 2009
Annual Inspection · Deficiency Check
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 3555233
10 November 2008
Deficiency Check · Hull Examination · DAPI Audit
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 3361876
12 July 2008
Deficiency Check · DAPI Audit · Annual Inspection
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 3301881
12 April 2007
COI Inspection
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 2895836
11 May 2006
Annual Inspection
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 2653236
13 April 2005
Periodic Inspection
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 2347280
10 November 2004
Hull Examination
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 2238870
22 April 2004
Re-Inspection
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 2050338
5 November 2003
Administrative Inspection
Administrative · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 1942650
19 May 2003
Re-Inspection
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 1827330
8 January 2002
COI Inspection
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 1478810
26 November 2001
Hull Examination
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 773172
15 February 2001
Re-Inspection
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 1410494
10 January 2001
Inclining Experiment
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 825538
19 April 2000
Deficiency Check
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 817733
19 April 2000
Deficiency Check
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 1049412
24 February 2000
Re-Inspection
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 1444289
20 August 1999
Type not recorded
No type recorded · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 61791
2 July 1999
Plan Review "T" Boat
Administrative · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 1087858
22 February 1999
Administrative
Administrative · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1130488
18 February 1999
COI Inspection · Deficiency Check
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 799008
6 November 1998
Hull Examination
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 805792
19 February 1998
Re-Inspection · MARPOL Annex V Examination
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1112773
7 February 1997
MARPOL Annex V Examination · Re-Inspection
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1104247
5 November 1996
Hull Examination
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1098319
21 February 1996
COI Inspection
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 885782
13 March 1995
Re-Inspection · MARPOL Annex V Examination
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 867055
19 December 1994
Hull Examination
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1152498
4 August 1994
Administrative
Administrative · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 860955
14 March 1994
Re-Inspection
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1166237
24 March 1993
Hull Examination
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1146623
19 March 1993
Type not recorded
No type recorded · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 826240
19 March 1993
COI Inspection
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1146621
19 May 1992
Re-Inspection
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1254900
20 June 1991
Hull Examination
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1252575
22 April 1991
Deficiency Check · Re-Inspection
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1236050
22 May 1990
COI Inspection
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1218909
14 December 1989
Hull Examination
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1228268
16 June 1989
Re-Inspection · Drydock Extension
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1032964
9 May 1988
Re-Inspection
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1045267
10 March 1988
Deficiency Check
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1198428
3 February 1988
Hull Examination
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1021640
15 December 1987
Administrative
Administrative · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1004289
18 November 1987
Deficiency Check
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1026013
13 April 1987
Deficiency Check · COI Inspection
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1010215
3 April 1986
Re-Inspection
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1308284
6 March 1986
Credit Drydock
Administrative · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1297411
16 April 1985
Type not recorded
No type recorded · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1289215
07 - Fire Safety › N/A - No Subsystem › Oil accumulation in engine room
Issued 27 May 2025
Resolved
The bilges and other spaces have no excessive accumulation oil that might create a fire hazard. Vessel's port main engine had extensive oil leak in the vicinity of the engine exhaust manifold. Identify cause of leak, repair and clean up excessive oil on engine, battery switch and bilges.
Condition: Damaged By Earlier Event
Action required: 701 - Prior to carriage of passengers/cargo
Due 3 June 2025
Resolved 30 May 2025
Resolution: Owner/operator cleaned up residual oil and fastened a new clamp on oil return hose.
01 - Certificates & Documentation › 013 - Documents › Signs, indications
Issued 27 May 2025
Resolved
Placards containing instructions for the donning and use of the lifejackets must be posted in conspicuous places. Vessel had two style of PFD and instructions for one PFD type only. Post donning instructions for both type PFD's.
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 10 June 2025
Resolved 30 May 2025
Resolution: Owner posted proper lifejacket donning instructions for both styles of PFD's.
11 - Life Saving Appliances › N/A - No Subsystem › Distress flares
Issued 27 May 2025
Resolved
A vessel on a lakes, bays and sounds route must carry 03 red flares and 03 orange smoke distress signals. Vessel had 03 expired red flares. Ensure vessel is provided with 03 additional red flares/orange smoke prior to carrying passengers.
Condition: Improper Installation
Action required: 701 - Prior to carriage of passengers/cargo
Due 3 June 2025
Resolved 30 May 2025
Resolution: Owner/operator provided non expired flares.
11 - Life Saving Appliances › N/A - No Subsystem › Rigid liferafts
Issued 27 May 2025
Resolved
Each item of survival craft equipment must be of good quality and efficient for the purpose it is intended to serve. Life float lights batteries were expired and retro tape was faded. Ensure batteries are proper non expired type and retro tape provides adequate reflection.
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 8 July 2025
Resolved 30 May 2025
Resolution: Owner/operator provided proper non expired battery and satisfactory retro.
04 - Emergency Systems › N/A - No Subsystem › Water level indicator
Issued 15 May 2023
Resolved
Vessel's greater than 26' in length must have a visual and audible alarm at the operating station to indicate high water level in the machinery space. Vessel's visual indicator for the #4 high water alarm in the engine compartment was not operating properly. Ensure proper operation of the visual indicator.
Condition: Damaged By Earlier Event
Action required: 16 - Rectify deficiencies w/in 14 days
Due 29 May 2023
Resolved 9 June 2023
Resolution: Owner installed new visual high water alarm. Alarm tested satisfactorily.
07 - Fire Safety › N/A - No Subsystem › Fire pumps and its pipes
Issued 15 May 2023
Resolved
All piping, valves, and fittings shall be in accordance with good marine practice and suitable for the purpose intended. Fire main piping was leaking water in the vicinity of the overboard discharge valve. Ensure fire main piping is no longer leaking in the vicinity of the overboard dicharge valve.
Condition: Damaged By Earlier Event
Action required: 16 - Rectify deficiencies w/in 14 days
Due 29 May 2023
Resolved 9 June 2023
Resolution: Owner repaired leaking fire main valve. Valve tested and no longer leaking water.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 15 May 2023
Resolved
Equipment mounted on a hinged door of an enclosure shall be shielded to from accidental contact by a person with the door open and circuit energized. Circuit breaker panel had openings to live circuits ensure a proper breaker or blank is installed.
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 29 May 2023
Resolved 9 June 2023
Resolution: Owner installed blanks in breaker box.
11 - Life Saving Appliances › N/A - No Subsystem › Operational readiness of lifesaving appliances
Issued 15 May 2023
Resolved
The float free link required by 180.130(a)(1) must be certified to meet 46 CFR 160.073 (Sub Q) and be of the proper strength and size for the life float indicated on the it's identification tag. Owner/operator could not provide weak link ID tag. Provide evidence that the weak link has an ID tag and that it is of suitable size and strength for life float.
Condition: Invalid
Action required: 16 - Rectify deficiencies w/in 14 days
Due 29 May 2023
Resolved 9 June 2023
Resolution: Owner installed two new valid weak links.
01 - Certificates & Documentation › 011 - Ships Certificates › Other (certificates)
Issued 15 May 2023
Resolved
[withheld — contains personal information; the deficiency system, dates, and resolution status are shown above]
Condition: Invalid
Action required: 16 - Rectify deficiencies w/in 14 days
Due 29 May 2023
Resolved 9 June 2023
Resolution: Owner provided new valid FCC Station License and Safety certificates.
09 - Working and Living Conditions › 092 - Working Conditions › Other (accident prevention)
Issued 9 May 2022
Resolved
No marine employer shall emply an individual to serve as a crewmember unless the individueal passes a chemical test for dangeroud drugs. Present crewmember is listed as "testing not conducted". 46CFR16.210
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 23 May 2022
Resolved 22 July 2022
Resolution: MI received and reviewed confirmation of enrollment for all licensed and unlicensed crew. Crew marked as "full compliance" until 6/30/2023.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 9 May 2022
Resolved
An adult life jacket must be carried for each person on board. Vessel has a total of 85 servicable adult life jackets on board. Vessel limited to 82 passengers until 03 servicable life jackets are placed on board to the satisfaction of the attending marine inspector. 46CFR180.71
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 9 May 2022
Resolved 10 May 2022
Resolution: New life jackets were installed on board the vessel.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 9 May 2022
Resolved
A vessel of at least 26' in length must be provided with individual bilge lines and suction for each watertight compartment. The vessel was not able to provide suction to the bilge piping system for the lazerette. Prior to carrying passengers demonstrate bilge piping can provide adequate suction to the lazerette to the satisfaction of the attending marine inspector. 46CFR182.510
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 9 May 2022
Resolved 10 May 2022
Resolution: A new bilge pump was installed and provided adequate suction.
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 13 May 2021
Resolved
The power fire pump shall be self priming and of such size as to discharge an effective stream from a hose. This pump may also be connected to the bilge system as described in 46 CFR 182.25, 46 CFR 181.10
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Due 13 May 2021
Resolved 13 May 2021
Resolution: Replacement pump impeller installed. Witnessed operation, all sat.
11 - Life Saving Appliances › N/A - No Subsystem › Stowage and provision of liferafts
Issued 13 May 2021
Resolved
The water light of an approved automatic electric type, constructed in accordance with 161.010. Marine Inspector discovered the vessel's three water lights did not operate or did not have the correct battery installed. Ensure proper installation prior to carrying passengers at night or during periods of limited visibility. 46 CFR 180.15-5 (d)
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Due 13 May 2021
Resolved 13 May 2021
Resolution: Proper batteries installed. Marine Inspector witnessed installation and working condition of water lights.
11 - Life Saving Appliances › N/A - No Subsystem › Distress flares
Issued 13 May 2021
Resolved
Six hand red flare distress signals approved in accordance with 46 CFR 160.021 in subchapter Q of this chapter. Marine Inspector observed the vessel has four valid red flares. Place six valid red flares on board prior to carrying passengers.
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Due 26 May 2021
Resolved 13 May 2021
Resolution: O/O purchased two replacement red flares and placed in service on vessel. All sat.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 13 May 2021
Resolved
Class II and III pressure vessels that have a net internal volume of less than 0.14 cubic meters (5 cubic feet) and do not contain hazardous materials must be stamped with either the ASME "U" or "UM" symbol. The vessel's air receiver does not have the proper approval stamp.
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 12 June 2021
Resolved 18 May 2021
Resolution: Marine Inspector verified pressure vessel meeting standard in 46 CFR 54.01-5 to be installed and fully operable. All sat.
Accommodation/Occupational Safety › Occupational Safety › Deck Rail
Issued 10 May 2017
Resolved
Secure upper deck STBD rail.
Action required: 705 - Other - as specified
Due 15 May 2017
Resolved 15 May 2017
Resolution: Verified rail was tightened and secured.
Lifesaving › Lifefloat › Floating Electric Waterlight
Issued 10 May 2017
Resolved
Provide new batteries for ring buoys/lifefloat lights.
Action required: 705 - Other - as specified
Due 15 May 2017
Resolved 15 May 2017
Resolution: New batteries are provided.
Documentation › Markings/Placards › Capacity Marking
Issued 10 May 2017
Resolved
Provide signage for toal number of passengers alllow on the upper deck.
Action required: 705 - Other - as specified
Due 15 May 2017
Resolved 15 May 2017
Resolution: Marking for upper deck pax limit is posted.
Lifesaving › Lifefloat › Retroreflective Material
Issued 10 May 2017
Resolved
Provide retro-flective tape on lifefloat.
Action required: 705 - Other - as specified
Due 15 May 2017
Resolved 15 May 2017
Resolution: New retroreflective tape is affixed.
Engineering › Fuel Oil Service System › Piping
Issued 10 May 2017
Resolved
Provide bonding wire for fuel tank fill piping.
Action required: 705 - Other - as specified
Due 15 May 2017
Resolved 15 May 2017
Resolution: Bonding wire is installed for both fuel fill hoses.
Accommodation/Occupational Safety › Occupational Safety › Guards for Exposed Hazards
Issued 10 May 2017
Resolved
Provide belt guard on STBD M/E alternator.
Action required: 705 - Other - as specified
Due 15 May 2017
Resolved 15 May 2017
Resolution: Belt guard is installed.
Lifesaving › Lifejacket/PFD (Type I) › Condition
Issued 10 May 2017
Resolved
Provide 23 adult lifejackets. Vessel is restricted to 64 passengers.
Action required: 705 - Other - as specified
Due 15 May 2017
Resolved 15 May 2017
Resolution: Required amount of lifejackets are now provided onboard.
Engineering › Shafting/Propeller Arrangements › Bearing
Issued 9 March 2015
Resolved
Work list Item JE01 - Replace intermediate shaft cutlass bearing on Port side.
Condition: Improper/Lack of Maintenance
Due 9 April 2015
Resolved 12 March 2015
Resolution: Bearing replaced.
Engineering › Fuel Oil Storage/Transfer System › Piping
Issued 9 March 2015
Resolved
Work list item JE03 - Plug unused fuel tank fittings on Starboard fuel tank.
Condition: Improper/Lack of Maintenance
Due 9 April 2015
Resolved 12 March 2015
Resolution: Fittings were plugged with threaded caps.
Engineering › Bilge Water Management System › Valve
Issued 9 March 2015
Resolved
Work list item JE04 - Repair reach rod for forward bilge shut off valve.
Condition: Improper/Lack of Maintenance
Due 9 April 2015
Resolved 12 March 2015
Resolution: Reach rod repaired and valve worked properly.
Construction/Loadline › Hull › Side Shell
Issued 9 March 2015
Resolved
Work list item JE02 - Repair areas of hull fiberglass as marked by USCG inspector. A couple of very small areas of glass had minor cracks. Marked with paint pen in field.
Condition: Improper/Lack of Maintenance
Due 9 April 2015
Resolved 12 March 2015
Resolution: Areas of hull marked were properly ground down and sealed with new resin.
Lifesaving › Lifefloat › Floating Electric Waterlight
Issued 15 May 2012
Resolved
Repair/Replace life float water light. Vessel restricted to daylight operations.
Action required: 705 - Other - as specified
Resolved 16 May 2012
Resolution: Life float light repaired.
Stability › Watertight Integrity › General
Issued 15 May 2012
Resolved
Install hatch cover retainer for anchor locker.
Due 22 May 2012
Resolved 16 May 2012
Resolution: Hatch cover retainer installed.
Operations/Management › Drug and Alcohol Testing › Recordkeeping
Issued 15 May 2012
Resolved
Provide documentation of drug testing background checks, alcohol testing devices, policy statement, crew member training.
Action required: 705 - Other - as specified
Due 15 July 2012
Resolved 3 January 2013
Resolution: Verified documentation, alcohol testing devices, policy statement and crew training.
Fire Fighting › Fixed CO2 Fire Extinguishing System › Location
Issued 13 July 2011
Resolved
Provide valid approved plans from MSC approving the fixed fire system in the E/R.
Action required: 705 - Other - as specified
Resolved 3 January 2013
Resolution: FIxed CO2 system plans APPROVED as per MSC letter dated July 19, 2012. Witnessed installation and testing of same this day.
Engineering › Shafting/Propeller Arrangements › Strut
Issued 8 November 2010
Resolved
Replace wasted strut block for stbd intermediate stern tube bearing.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 20 April 2011
Engineering › Steering Gear System › Linkage
Issued 8 November 2010
Resolved
Repair/replace port side steering knuckle on actuator arm.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 20 April 2011
Engineering › Steering Gear System › Bracket/Clamp
Issued 8 November 2010
Resolved
Repair broken steering blocking at transom bulkhead.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 20 April 2011
Accommodation/Occupational Safety › Occupational Safety › Deck Rail
Issued 8 November 2010
Resolved
Provide an additional rail course to railing to make course no more than 4 inches.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 15 May 2012
Resolution: Rail courses installed on upper deck rails.
Pollution Prevention/Response › Prevention Equipment › Sewage System Valve
Issued 8 November 2010
Resolved
provide handle for stbd sewage ovbd valve.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 20 April 2011
Construction/Loadline › Hull › Bottom Plating
Issued 8 November 2010
Resolved
Address areas identified on hull and investigate further cause of cracking.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 20 April 2011
Construction/Loadline › Structures › Transverse Bulkhead
Issued 8 November 2010
Resolved
Make fwd bulkhead of E/R airtight around penetrations.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 24 May 2011
Resolution: All penetrations were made air tight.
Documentation › Markings/Placards › Capacity Marking
Issued 8 November 2010
Resolved
Label upper deck 20 pax max.
Due 1 June 2011
Resolved 26 May 2011
Resolution: Upper deck labeled.
Documentation › Manuals/Policy Documentation › Emergency Instructions
Issued 8 November 2010
Resolved
Post emergency instructions in accomodation space.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 26 May 2011
Resolution: Instructions posted.
Documentation › Certificates/Documents › Certificate of Inspection
Issued 8 November 2010
Resolved
Post COI in accomodations space.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 26 May 2011
Resolution: COI posted.
Lifesaving › Lifejacket/PFD (Type I) › Quantity
Issued 8 November 2010
Resolved
Vessel restricted to 82 adult passengers, due life jacket count.
Action required: 705 - Other - as specified
Resolved 16 May 2012
Resolution: Five (5) lifejackets provided.
Operations/Management › Pollution › Retention of Oily Mixture
Issued 8 November 2010
Resolved
Post no oil discharge placard in E/R.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 26 May 2011
Resolution: Placard posted.
Documentation › Safety/Response Plans/Programs › Waste Management Plan
Issued 8 November 2010
Resolved
Post Marpol v garbage placard.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 26 May 2011
Resolution: Sticker posted.
Deck/Cargo › Holds/Tanks › Hatch Cover
Issued 8 November 2010
Resolved
Secure fwd scuttle to vessel with a suitable lanyard.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 26 May 2011
Resolution: scuttle had a lanyard.
Electrical › Electrical Distribution System (service) › Grounding Conductor
Issued 8 November 2010
Resolved
Install grounding wire on new shaft log's.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 26 May 2011
Resolution: Wire installed.
Documentation › Markings/Placards › Lifejacket Placard
Issued 8 November 2010
Resolved
Post life jacket donning placard in accomodation space.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 26 May 2011
Resolution: Placard posted.
Fire Fighting › Fixed CO2 Fire Extinguishing System › Operating Instructions
Issued 8 November 2010
Resolved
Post operating instructins near CO2 operating head.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 26 May 2011
Resolution: Operating instructions posted.
Fire Fighting › Fixed CO2 Fire Extinguishing System › Piping
Issued 8 November 2010
Resolved
Install schedule 40 "T" beyond the discharge nozzle in the piping system in the E/R.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 26 May 2011
Resolution: Scedule 40 T and nipples with caps installed.
Navigation › Piloting/Steering › Tide/Tidal Current Tables
Issued 8 November 2010
Resolved
Provide current tides and current tables.
Due 7 June 2011
Resolved 26 May 2011
Resolution: Current tide tables and charts on-board.
Navigation › Piloting/Steering › US Coast Pilot
Issued 8 November 2010
Resolved
Provide current coast pilot for area identified on COI.
Due 7 June 2011
Resolved 26 May 2011
Resolution: Current coast pilot on-board.
Documentation › Certificates/Documents › FCC SSL
Issued 8 November 2010
Resolved
Provide valid safety radio certificate.
Due 7 June 2011
Resolved 26 May 2011
Resolution: Valid safety cert on-board.
Electrical › Electric Supply System (service) › Cable
Issued 8 November 2010
Resolved
Install metal hanging clamps on wires throughout the vessel where identified.
Due 7 June 2011
Resolved 26 May 2011
Resolution: Hangers installed.
Operations/Management › Drug and Alcohol Testing › Testing, Equipment
Issued 22 July 2009
Resolved
Alcohol test kits not maintained on-board vessel. Obtain alcohol test kits or supply a letter from a local law enforcement agency stating that they can test crew for alcohol within 2 hours of marine casuality.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 22 August 2009
Resolved 1 September 2009
Resolution: Received email receipt of alcohol test kit.
Engineering › Diesel Engine (propulsion-direct drive) › Piping (exhaust)
Issued 22 July 2009
Resolved
Inboard exhaust insulation/lagging missing from both port and starboard engine exhaust pipes. Replace as new to the satisfaction of the CG Marine Inspector.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 22 August 2009
Resolved 1 September 2009
Resolution: Insulation/lagging installed on both the port and starboard exhaust pipes.
Stability › Watertight Integrity › General
Issued 22 July 2009
Resolved
Packing on port rudder post allowing excess water to enter bilge. Tighten as necessary.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 22 August 2009
Resolved 22 July 2009
Resolution: Packing on port rudder post tightened.
Accommodation/Occupational Safety › Other Accommodation Spaces › Open Deck Space
Issued 22 July 2009
Resolved
Number of persons allowed on the upper deck not posted (weathered away). Re-stencil as appropriate.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 22 August 2009
Resolved 1 September 2009
Resolution: Number of persons allowed on upper deck re-stenciled on stairway leading to upper deck.
Navigation › Collision/Grounding Avoidance › Navigation Lights
Issued 22 July 2009
Resolved
Anchor light lens crushed, replace as new.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 22 August 2009
Resolved 1 September 2009
Resolution: Anchor light lens replaced.
Accommodation/Occupational Safety › Occupational Safety › Deck Rail
Issued 22 July 2009
Resolved
Plywood sheathing underneath hand rails on upper deck removed, leaving screws exposed. Gring down/remove screws or cover with new sheathing to the satisfaction of the CG Marine Inspector.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 22 August 2009
Resolved 1 September 2009
Resolution: Screws on plywood sheathing ground down.
Construction/Loadline › Structures › Superstructure
Issued 22 July 2009
Resolved
2 bridge windows cracked, replace as new to the satisfaction of the CG Marine Inspector.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 1 September 2009
Resolved 9 September 2009
Resolution: Bridge windows replaced.
Construction/Loadline › Hull › Hull Plating
Issued 10 November 2008
Resolved
Vessel currently has two wasted bronze 2" x 12" water planing strips that attach the the external hull structure near the stern of the vessel. Vessel owner stated that the purpose is to increase water planing and stability.
Action required: 705 - Other - as specified
Due 12 November 2008
Resolved 12 November 2008
Resolution: Vessel owner replaced wasted external structural supports for proper planing in the water. Pictures have been placed in vessel''s current file.
Construction/Loadline › Hull › Longitudinal Frame
Issued 10 November 2008
Resolved
The engine space contains a longitudinal frame that has a significant amount of angel hair which exceeds 50% of the mandated wastage level. Vessel owner stated that he will remove the frame and sister a similar longitudinal frame in the engine space.
Action required: 705 - Other - as specified
Due 12 November 2008
Resolved 12 November 2008
Resolution: Vessel owner replaced the longitudinal frame in a satisfactory manner.
Lifesaving › Lifejacket/PFD (General) › Quantity
Issued 12 July 2008
Resolved
Vessel currently has 16 PFD which are un-sat. Vessel owner informed that he must replace in-kind w/ approved CG Type I PFD's
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 30 July 2008
Resolution: Vessel owner placed 16 Type I PFD''s on-board vessel.
Lifesaving › Lifefloat › Paddle
Issued 12 July 2008
Resolved
Vessel has 02 paddles which are currently un-sat. Vessel operator informed that he must place 02 CG approved paddles on-board stbd life float.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 30 July 2008
Resolution: vessel owner placed 02 floatable paddles on-board stbd life float.
Electrical › Electrical Distribution System (emergency) › Wiring
Issued 12 July 2008
Resolved
Vessel currently has wire nuts loosely holding together wires in the lazarette compartment. Vessel owner informed that he must secure wire connections with an appropriate CG approved means.
Action required: 705 - Other - as specified
Due 27 August 2008
Resolved 27 August 2008
Electrical › Electric Generation Source (service) › Power Requirement
Issued 12 July 2008
Resolved
The shore connection to the vessel is currently hanging loosely from the port bulkhead. Vessel owner must secure the shore connection mount appropriately to the bulkhead.
Action required: 705 - Other - as specified
Due 27 August 2008
Resolved 27 August 2008
Accommodation/Occupational Safety › Heating › Metal Protection
Issued 12 July 2008
Resolved
The heat duct in the engine space is currently wasted and must be replaced in-kind.
Action required: 705 - Other - as specified
Due 27 August 2008
Resolved 27 August 2008
Lifesaving › Buoyant Apparatus › Lifeline
Issued 11 May 2006
Resolved
Replace all life lines and pendants on BA's.
Action required: 701 - Prior to carriage of passengers/cargo
Due 11 May 2006
Resolved 18 May 2006
Resolution: Replaced all lines on BA''''s. Verified by marine inspector.
Lifesaving › Buoyant Apparatus › Float-free Link
Issued 11 May 2006
Resolved
Provide proof of weak link rating for BA's.
Action required: 701 - Prior to carriage of passengers/cargo
Due 11 May 2006
Resolved 18 May 2006
Resolution: Replaced all weak links to BA''s. Verified by marine inspector.
Communications › Internal Communications System › Portable Radios
Issued 11 May 2006
Resolved
Provide operational public address system.
Action required: 705 - Other - as specified
Due 21 May 2006
Resolved 18 May 2006
Resolution: Made repairs to installed PA system. Verified by marine inspector.
Engineering › Freshwater System (jacketwater cooling) › Piping
Issued 11 May 2006
Resolved
Remove duck tape from cooling hose to allow pipe for visual inspection.
Action required: 705 - Other - as specified
Due 21 May 2006
Resolved 18 May 2006
Resolution: Duck tape removed. Pipe inspected by marine inspector.
Operations/Management › Drug and Alcohol Testing › Proof of Enrollment
Issued 13 April 2005
Resolved
Provide proof of enrollment in CG approved drug testing program.
Action required: 701 - Prior to carriage of passengers/cargo
Due 13 April 2005
Resolved 2 May 2005
Documentation › Certificates/Documents › FCC SSL
Issued 13 April 2005
Resolved
Provide valid FCC safety certificate.
Action required: 705 - Other - as specified
Due 13 May 2005
Resolved 2 May 2005
Navigation › Collision/Grounding Avoidance › Navigation Lights
Issued 13 April 2005
Resolved
Replace bulb for sternlight. Restricted to daytime operations until completed.
Action required: 705 - Other - as specified
Due 13 May 2005
Resolved 2 May 2005
Construction/Loadline › Hull › Keel
Issued 10 November 2004
Resolved
Crop and renew all areas of delaminated fiberglass on keel.
Due 10 November 2004
Resolved 29 November 2004
Resolution: Vessel owner to send pictures of repairs.
Construction/Loadline › Penetrations › Valve Flange
Issued 10 November 2004
Resolved
Replace ball valve for washdown pump intake located in lazarette.
Due 10 November 2004
Resolved 29 November 2004
Stability › Watertight Integrity
Issued 19 May 2003
Resolved
Repair high water alarm in engine room
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 19 May 2003
Lifesaving › Lifebuoys › Buoyant Lifeline
Issued 19 May 2003
Resolved
Provide 5/16" throw line for ring buoy
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 19 May 2003
Lifesaving › Buoyant Apparatus
Issued 19 May 2003
Resolved
Lash paddles to life floats
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 19 May 2003
Pollution Prevention/Response › Prevention Equipment › Sewage System Piping
Issued 19 May 2003
Resolved
Close MSD discharge ovbd valve and remove valve handle
Due 19 June 2003
Resolved 19 May 2003
Accommodation/Occupational Safety › Occupational Safety › Guards for Exposed Hazards
Issued 19 May 2003
Resolved
Provide machinery guard on stbd MDE belts
Due 19 June 2003
Resolved 31 May 2007
Resolution: "Misle had existing deficiencies still in the system that were cleared but not checked as "inspection satisfactory", therefore,the summary reflect deficiencies as being corrected even though no deficiencies were associated with the inspection.
Accommodation/Occupational Safety › Occupational Safety › Guards for Exposed Hazards
Issued 19 May 2003
Resolved
Repair lagging on port MDE exhaust
Due 19 June 2003
Resolved 19 May 2003
Operations/Management › Passenger Operations
Issued 19 May 2003
Resolved
Label upper deck with max person capacity iaw stability ltr
Due 19 June 2003
Resolved 19 May 2003
Electrical
Issued 15 February 2001
Resolved
PROVIDE VOLTAGE AND AMPERAGE METER FOR GENERATORS.
Condition: Unknown
Due 15 March 2001
Resolved 1 March 2001
Fire Fighting
Issued 15 February 2001
Resolved
PROVIDE NOZZLE FOR FIRE HOSE.
Condition: Unknown
Due 23 February 2001
Resolved 1 March 2001
Electrical
Issued 15 February 2001
Resolved
PROVIDE ELECTRICAL MAT AT SWITCHBOARD
Condition: Unknown
Due 15 March 2001
Resolved 1 March 2001
Lifesaving
Issued 24 February 2000
Resolved
RENEW LINE TO RING LIFE BUOY.
Condition: Unknown
Due 24 February 2000
Resolved 24 February 2000
Lifesaving
Issued 24 February 2000
Resolved
PROVIDE MONTHLY TEST LOG FOR 406 EPIRB.
Condition: Unknown
Due 24 February 2000
Resolved 24 February 2000
Lifesaving
Issued 24 February 2000
Resolved
CONDUCT UNERWAY DRILLS & UNDERWAY INSPECTION OF MDE, STEERING AND HULL.
Condition: Unknown
Due 24 February 2000
Resolved 24 February 2000
Documentation
Issued 18 February 1999
Resolved
CONDUCT STABILITY TEST PRIOR TO ALLOWING ANY PASSENGERS ON UPPER DECK WHEN CARRYING MORE THAN 77 PASSENGERS.
Condition: Unknown
Due 18 February 1999
Resolved 18 February 1999
Documentation
Issued 22 April 1991
Resolved
PROVIDE CURRENT PUBS. (TIDE TABLE, CURRENT TABLES, RULES FOR T-BOATS, COASTPILOT )_x001C_ _x001C_ _x001C_
Condition: Unknown
Due 22 April 1991
Resolved 22 April 1991
Unknown
Issued 22 April 1991
Resolved
REPAIR BILGE PIPE CONTROL VALVE IN FOREPEAK AND RECONNECT REACH RID
Condition: Unknown
Due 22 April 1991
Resolved 22 April 1991
Lifesaving
Issued 22 April 1991
Resolved
MARK VESSELS NAME ON RING BUOY_x001C_ _x001C_ _x001C_ _x001C_
Condition: Unknown
Due 22 April 1991
Resolved 22 April 1991
Construction/Loadline
Issued 22 April 1991
Resolved
REPAIR OR RENEW WORN AND FRACTURED HATCH COVER TO FOREPEAK_x001C_ _x001C_ _x001C_ _x001C_
Condition: Unknown
Due 22 April 1991
Resolved 22 April 1991
Fire Fighting
Issued 22 April 1991
Resolved
REPAINT FIRE EXTINGUISHERS_x001C_ _x001C_ _x001C_ _x001C_
Condition: Unknown
Due 22 April 1991
Resolved 22 April 1991
Lifesaving
Issued 22 April 1991
Resolved
RENEW LIFELINES ON BUOYANT APPARATUS AND PENDANTS TO BE FAKED DOWN PROPERLY_x001C_ _x001C_ _x001C_
Condition: Unknown
Due 22 April 1991
Resolved 22 April 1991
Electrical
Issued 22 May 1990
Resolved
PROVED OPERATION OF #1 AUX GENERATOR.
Condition: Unknown
Due 22 May 1990
Resolved 22 May 1990
Engineering
Issued 22 May 1990
Resolved
CONDUCT A HYDROTEST ON THE AUXILIARY HEATING BOILER PRIOR TO PLACING IN USE.
Condition: Unknown
Due 22 May 1990
Resolved 22 May 1990
Electrical
Issued 9 May 1988
Resolved
PROVIDE A SHUT-OFF SWITCH FOR THE BATTERIES ON THE SHIP'S SERVICE GENERATORS.
Condition: Unknown
Due 9 May 1988
Resolved 9 May 1988
Construction/Loadline
Issued 9 May 1988
Resolved
SEAL BHD PENETRATIONS IN 2ND TRANSVERSE BHD.
Condition: Unknown
Due 9 May 1988
Resolved 9 May 1988
Lifesaving
Issued 9 May 1988
Resolved
RENEW LIFELINE ON INSIDE OF BOTH LIFE FLOATS.
Condition: Unknown
Due 9 May 1988
Resolved 9 May 1988
Lifesaving
Issued 9 May 1988
Resolved
REMOUNT WATERLIGHT BRACKETS IN VICINITY OF RING BUOY AND LIFEFLOATS.
Condition: Unknown
Due 9 May 1988
Resolved 9 May 1988
Engineering
Issued 9 May 1988
Resolved
PROVIDE FLAME SCREENS FOR FUEL TANK VENTS.
Condition: Unknown
Due 9 May 1988
Resolved 9 May 1988
Electrical
Issued 9 May 1988
Resolved
REMOVE WIRE NUTS AND RESPLICE PROPERLY THE WIRE TO THE GOVERNOR CONTROL ON THE PORT SHIP'S SERVICE GENERATOR.
Condition: Unknown
Due 9 May 1988
Resolved 9 May 1988
Engineering
Issued 3 February 1988
Resolved
OPEN THE PORT BILGE OVERBOARD VALVE IN THE ENGINE ROOM FOR INSPECTION BY A USCG MARINE INSPECTOR.
Condition: Unknown
Due 3 February 1988
Resolved 3 February 1988
Accommodation/Occupational Safety
Issued 3 February 1988
Resolved
REALIGN THE OVERBOARD DRAIN PIPING FROM THE STARBOARD HEAD DRAIN WHERE IT CONNECTS TO THE THROUGH HULL FITTING.
Condition: Unknown
Due 3 February 1988
Resolved 3 February 1988
Navigation
Issued 13 April 1987
Resolved
MOVE MASTHEAD LIGHT FORWARD OF SIDE LIGHTS.
Condition: Unknown
Due 13 April 1987
Resolved 13 April 1987
Unknown
Issued 13 April 1987
Resolved
PROVIDE LOCKS FOR DUMP VALVES IN PASSENGER SPACES TO PREVENT PASSENGERS FROM ACCIDENTALLY OPENING THE HOLDING TANK FOR SEWAGE.
Condition: Unknown
Due 13 April 1987
Resolved 13 April 1987
Electrical
Issued 13 April 1987
Resolved
PROVE OPERATION OF THE PORT AUXILIARY GENERATOR.
Condition: Unknown
Due 13 April 1987
Resolved 13 April 1987
Accommodation/Occupational Safety
Issued 13 April 1987
Resolved
INSTALL AN EXTENSION ON ONE EXHAUST AIR VENT PIPE SO THAT IT REACHES NEAR TO THE BOTTOM OF THE MACHINERY SPACE.
Condition: Unknown
Due 13 April 1987
Resolved 13 April 1987
Engineering
Issued 13 April 1987
Resolved
INSTALL AN EXTENSION PIPE ON RELIEF VALVE SAFETY BLOW DOWN FOR DOMESTIC HOTWATER BOILER TO DIRECT DISCHARGE DOWN TO BILGE.
Condition: Unknown
Due 13 April 1987
Resolved 13 April 1987
Documentation
Issued 13 April 1987
Resolved
PROVIDE FCC OPERATORS LICENSE.
Condition: Unknown
Due 13 April 1987
Resolved 13 April 1987
Accommodation/Occupational Safety
Issued 13 April 1987
Resolved
REPLACE BROKEN WINDOW IN WHEELHOUSE.
Condition: Unknown
Due 13 April 1987
Resolved 13 April 1987
Fire Fighting
Issued 13 April 1987
Resolved
PROVIDE ONE ADDITIONAL B-II FIRE EXTINGUISHER FOR THE ACCOMMODATION SPACE.
Condition: Unknown
Due 13 April 1987
Resolved 13 April 1987
Lifesaving
Issued 13 April 1987
Resolved
PROVIDE ADDITIONAL REFLECTIVE MATERIAL ON TOP/BACK OF LIFE PRESERVERS TO OBTAIN THE REQUIRED 31 SQ. IN.
Condition: Unknown
Due 13 April 1987
Resolved 13 April 1987
Construction/Loadline
Issued 13 April 1987
Resolved
PROVIDE A NEW HATCH COVER WITH DOGS AND A SECURING CHAIN FOR THE LAZZARETT.
Condition: Unknown
Due 13 April 1987
Resolved 13 April 1987
Fire Fighting
Issued 3 April 1986
Resolved
PROVIDE 50 FT. FIRE HOSE AS REQUIRED BY 46 CFR 181.15-10(B).
Condition: Unknown
Due 3 April 1986
Resolved 3 April 1986