MAURY USCG vessel records Sign in
← All vessels

AIKANE III

AIKANE III is a 1974 passenger vessel (inspected). The Coast Guard has recorded 80 inspections since 1984, most recently in October 2020, along with 247 deficiencies and 5 operational controls.

Records from 1984 to 2020. Most recent: inspection, 26 October 2020.

Built
1974
Last inspected
26 October 2020
Documentation
Not in the documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

WDG2828
Flag
UNITED STATES
367360010, 367510440, 367519710 (licence lapsed)
Maury page id
psix-48081

Inspections, by type

…with no type recorded9
Years with a record 29 calendar years (1984–2020)
The 80 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

This record may be incomplete: the most recent inspection recorded for this vessel was 6 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Passenger Ship class in Maury's sources begin in 1977.

Documentation record

Tonnage as PSIX records it39 - Simplified, Gross Ton
31 - Simplified, Net Ton
This hull's Official Number is not in the NVDC file dated 10 September 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.

Radio station licence

WDG2828MMSI 367519710 · cancelled · compulsorily equipped · granted 28 February 2012, cancelled 2 October 2015
WDF9941MMSI 367510440 · expired · compulsorily equipped · granted 24 November 2011, cancelled 29 January 2022
WBR8425MMSI 367360010 · cancelled · voluntarily equipped · granted 31 May 2008, cancelled 11 February 2016
FCC Universal Licensing System ship-station file of 6 September 2026, matched to this hull on its US Official Number. Status and dates are the file’s own. The licensee is not read from the file and is not shown. A lapsed licence’s MMSI is still the number the vessel transmitted under while it was valid.

Inspection history · 80

26 October 2020 Administrative Inspection
Administrative · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 7084693
14 November 2017 Administrative Inspection
Administrative · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 6306982
13 July 2011 COI Inspection · Deficiency Check · Initial Certification · Examination of Repairs
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 4080444
2 February 2011 Administrative Inspection
Administrative · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 3937816
31 January 2011 Hull Examination
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 3936524
29 July 2009 Deficiency Check · Annual Inspection · DAPI Audit
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 3549656
4 February 2009 Deficiency Check · Hull Examination · Administrative Inspection
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 3387089
8 January 2009 Type not recorded
No type recorded · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 3390943
10 December 2008 In-Service Inspection · Deficiency Check
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 3377950
22 October 2008 Type not recorded
No type recorded · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 3390539
20 May 2008 Annual Inspection · Deficiency Check
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 3206705
16 January 2008 Damage Survey
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 3131798
11 October 2007 Annual Inspection · Deficiency Check
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 3077864
25 April 2007 Type not recorded
No type recorded · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 2916454
31 May 2006 Deficiency Check · COI Inspection
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 2677801
2 February 2005 Plan Review "T" Boat
Administrative · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 2285563
7 January 2005 Annual Inspection · Damage Survey
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 2269348
30 November 2004 Deficiency Check
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 2254390
29 April 2004 Hull Examination · Deficiency Check · Administrative Inspection
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 2049493
6 February 2004 Annual Inspection
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1997638
16 January 2003 Administrative Inspection · Annual Inspection
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1728167
27 March 2002 Hull Examination
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1496120
12 October 2001 COI Inspection
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1382418
28 June 2001 Administrative
Administrative · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1067145
14 July 2000 Deficiency Check
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 819839
3 July 2000 Hull Examination
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1361590
25 April 2000 Drydock Extension
Administrative · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 817632
27 January 2000 Deficiency Check
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 813970
28 December 1999 Deficiency Check
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1381758
14 December 1999 Re-Inspection
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1381757
28 June 1999 Damage Survey
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1413564
24 June 1999 Type not recorded
No type recorded · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 141115
15 October 1998 MARPOL Annex V Examination · COI Inspection
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1406380
8 May 1998 Administrative
Administrative · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1124990
6 April 1998 MARPOL Annex V Examination · Hull Examination
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1400754
19 November 1997 MARPOL Annex V Examination · Re-Inspection
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1390655
3 June 1997 Administrative
Administrative · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 773882
1 May 1997 Administrative
Administrative · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1097227
5 February 1997 Administrative
Administrative · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1104825
24 December 1996 Deficiency Check
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1096049
11 December 1996 Re-Inspection · MARPOL Annex V Examination
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1356028
30 September 1996 Hull Examination
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1377826
5 June 1996 Drydock Extension
Administrative · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1353940
27 February 1996 Deficiency Check
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 884973
26 October 1995 MARPOL Annex V Examination · COI Inspection
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1355506
10 October 1995 Administrative
Administrative · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1187497
20 March 1995 Deficiency Check
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1357084
3 March 1995 Deficiency Check
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1357037
6 February 1995 Deficiency Check
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1367285
6 January 1995 Hull Examination
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1425533
18 November 1994 Deficiency Check
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1394223
28 October 1994 Re-Inspection
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1414376
23 November 1993 Deficiency Check
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1439454
21 October 1993 Re-Inspection
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1391906
19 November 1992 Hull Examination
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1138685
26 October 1992 COI Inspection
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 951543
2 September 1992 Drydock Extension
Administrative · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 961838
1 May 1992 Type not recorded
No type recorded · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 963037
25 October 1991 Re-Inspection
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1248514
13 February 1991 Hull Examination
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 907389
29 January 1991 Type not recorded
No type recorded · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1233114
25 October 1990 Re-Inspection
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1237150
14 June 1990 Deficiency Check
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1226510
26 October 1989 COI Inspection
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 898150
26 October 1989 Damage Survey · Hull Examination
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1199648
11 May 1989 Damage Survey
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 896071
14 December 1988 Deficiency Check
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 898729
11 October 1988 COI Inspection
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 898726
9 June 1988 Administrative
Administrative · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1033540
7 January 1988 Hull Examination
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1019959
16 December 1987 Damage Survey
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1006198
29 October 1987 Re-Inspection
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1329043
9 October 1986 Re-Inspection
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1319761
8 September 1986 Examination of Repairs
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1032028
9 June 1986 Credit Drydock
Administrative · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 990312
12 November 1985 Deficiency Check
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1301524
11 October 1985 COI Inspection
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1298228
14 January 1985 Type not recorded
No type recorded · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1286962
12 December 1984 Type not recorded
No type recorded · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 977466
27 November 1984 Type not recorded
No type recorded · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1283798

Deficiency record · 247

Operations/Management › Drug and Alcohol Testing › Recordkeeping
Issued 29 July 2009 Resolved
Conduct satisfactory Drug & Alcohol program audit with USCG.
Condition: Unknown
Action required: 705 - Other - as specified
Due 29 August 2009
Resolved 2 September 2009
Navigation › Piloting/Steering › Marine Charts
Issued 29 July 2009 Resolved
Provide corrected charts for op area.
Condition: Unknown
Action required: 705 - Other - as specified
Due 29 August 2009
Resolved 3 August 2009
Resolution: Provided corrected charts for op area.
Accommodation/Occupational Safety › Medical/First Aid › Medicine Chest
Issued 29 July 2009 Resolved
Replace expired eyewash in first aid kit.
Condition: Unknown
Action required: 705 - Other - as specified
Due 29 August 2009
Resolved 25 September 2009
Lifesaving › Lifejacket/PFD (General) › Marking
Issued 29 July 2009 Resolved
Correct # of PFD's on storage labels.
Condition: Unknown
Action required: 705 - Other - as specified
Due 29 August 2009
Resolved 3 August 2009
Resolution: Corrected labels.
Communications › Public Address System › Loudspeaker
Issued 29 July 2009 Resolved
Provide bullhorn & prove proper operation.
Condition: Unknown
Action required: 705 - Other - as specified
Due 29 August 2009
Resolved 3 August 2009
Resolution: Provided bullhorn & prove proper operation.
Lifesaving › Buoyant Apparatus › Floating Electric Waterlight
Issued 29 July 2009 Resolved
Renew water light.
Condition: Unknown
Action required: 705 - Other - as specified
Due 29 August 2009
Resolved 3 August 2009
Resolution: Renewed water light.
Navigation › Piloting/Steering › Binnacle
Issued 29 July 2009 Resolved
Repair & prove proper operation of compass light.
Condition: Unknown
Action required: 705 - Other - as specified
Due 29 August 2009
Resolved 3 August 2009
Resolution: Repair & prove proper operation of compass light.
Engineering › Bilge Water Management System › Interface Detector
Issued 29 July 2009 Resolved
Port side bilge high level alarm / repair light for indicator located on operating station.
Condition: Unknown
Action required: 705 - Other - as specified
Due 29 August 2009
Resolved 3 August 2009
Resolution: Port side bilge high level alarm / repaired light for indicator located on operating station.
Fire Fighting › Miscellaneous Items › A Class Division Penetrations
Issued 29 July 2009 Resolved
Make bulkhead between generator space & sewage space on the port side vapor tight.
Condition: Unknown
Action required: 705 - Other - as specified
Due 29 August 2009
Resolved 3 August 2009
Resolution: Made bulkhead between generator space & sewage space on the port side vapor tight.
Engineering › Diesel Engine (propulsion-direct drive) › Piping (exhaust)
Issued 29 July 2009 Resolved
Repair exhaust leak & renew lagging on port main diesel engine
Condition: Unknown
Action required: 705 - Other - as specified
Due 29 August 2009
Resolved 3 August 2009
Resolution: Repair exhaust leak & renew lagging on port main diesel engine
Fire Fighting › Miscellaneous Items › A Class Division Penetrations
Issued 29 July 2009 Resolved
Make engine room bulkheads vapor tight.
Condition: Unknown
Action required: 705 - Other - as specified
Due 29 August 2009
Resolved 25 September 2009
Stability › Watertight Integrity › General
Issued 29 July 2009 Resolved
Renew missing dogs on all port lights below main deck.
Condition: Unknown
Action required: 705 - Other - as specified
Due 29 August 2009
Resolved 3 August 2009
Resolution: Renewed missing dogs on all port lights below main deck.
Engineering › Bilge Water Management System › Pump
Issued 29 July 2009 Resolved
Reengineer bilge/fire pump clutch to allow activation & prevent crew from climbing over engine while underway. Submit plans prior to making modification.
Condition: Design Flaw
Action required: 705 - Other - as specified
Due 29 August 2009
Resolved 25 September 2009
Fire Fighting › Fire Pumps › Arrangement
Issued 29 July 2009 Resolved
Prove proper operation of fixed firefighting & bilge/fire pump.
Condition: Unknown
Action required: 705 - Other - as specified
Due 29 August 2009
Resolved 3 August 2009
Resolution: Proved proper operation of fixed firefighting & bilge/fire pump.
Engineering › Sea-water System (primary cooling) › Valve
Issued 5 February 2009 Resolved
Replace stbd side fire pump gate valve (inoperable) and port side fire pump suction ball valve (deep pit).
Action required: 705 - Other - as specified
Resolved 16 March 2009
Resolution: Both valves were replaced.
Engineering › Fuel Oil Service System › Tank
Issued 4 February 2009 Resolved
Replace fuel tanks in port and stbd engine rooms and generator fuel tank IAW 46 CFR 182.440.
Action required: 705 - Other - as specified
Resolved 1 May 2009
Resolution: Witnessed proper installation and operation of all three fuel tanks.
Engineering › Shafting/Propeller Arrangements › Propeller Shaft
Issued 4 February 2009 Resolved
Determine extent of corrosion on port and stbd shafts. Provide proof of NDT results & make repairs as necessary.
Action required: 705 - Other - as specified
Resolved 16 March 2009
Resolution: Replaced port and stbd shafts.
Engineering › Shafting/Propeller Arrangements › Propeller (fixed pitch)
Issued 4 February 2009 Resolved
Remove propellers & repair or replace as necessary.
Action required: 705 - Other - as specified
Resolved 16 March 2009
Resolution: Replaced port and stbd propellers.
Construction/Loadline › Hull › Keel Plate
Issued 4 February 2009 Resolved
Remove all skid plates. Grind down area underneath to good wood and determine extent of wood rot. Provide repair proposal based on findings.
Action required: 705 - Other - as specified
Resolved 24 February 2009
Resolution: Removed skid plates and bolts connecting plates to hull. Filled bolt holes with dowel rods and 5200. Fiberglassed over on inside and replaced plate area built up fiberglass.
Engineering › Steering Gear System › Rudder
Issued 4 February 2009 Resolved
Found significant damage on stbd rudder. Provide repair proposal & make repairs IAW proposal.
Action required: 705 - Other - as specified
Resolved 16 March 2009
Resolution: Made proper repairs to stbd rudders.
Engineering › Steering Gear System › Rudder
Issued 4 February 2009 Resolved
Make repairs to damage located on top of port rudder.
Action required: 705 - Other - as specified
Resolved 16 March 2009
Resolution: Made proper repairs to port rudder.
Construction/Loadline › Hull › Hull Plating
Issued 4 February 2009 Resolved
Grind down center wing area to good wood and determine extent of rot. Provide repair proposal as necessary.
Action required: 705 - Other - as specified
Resolved 24 February 2009
Resolution: Removed paint and found wood in good condition.
Construction/Loadline › Hull › Hull Plating
Issued 4 February 2009 Resolved
Grind down and determine extent of damage to fiberglass on indicated areas of external hull. Make repairs as necessary.
Action required: 705 - Other - as specified
Resolved 24 February 2009
Resolution: Made repairs to all indicated areas on external hull.
Construction/Loadline › Hull › Hull Plating
Issued 4 February 2009 Resolved
Repair screw holes on stbd side around fire pump thru hull.
Action required: 705 - Other - as specified
Resolved 24 February 2009
Resolution: Filled holes and glassed over area to repair screw holes in area.
Construction/Loadline › Hull › Hull Plating
Issued 4 February 2009 Resolved
Make repairs to fiberglass on port and stbd stem areas.
Action required: 705 - Other - as specified
Resolved 24 February 2009
Resolution: Reglassed damaged areas on port and stbd stem areas.
Construction/Loadline › Hull › Bracket
Issued 4 February 2009 Resolved
Grind down to good wood and determine extent of damage to stbd side swim platform step. Provide repair proposal as necessary.
Action required: 705 - Other - as specified
Resolved 24 February 2009
Resolution: Removed step on stbd swim platform. Reglassed area.
Construction/Loadline › Hull › Stringer
Issued 4 February 2009 Resolved
Grind down stbd rub rails to good wood in exposed areas and determine extent of damage. Replace metal rail as necessary and provide repair proposal & maintain fasteners for CG inspection.
Action required: 705 - Other - as specified
Resolved 16 March 2009
Resolution: Sanded rub rail to good wood and replaced approx 18" section of wood.
Construction/Loadline › Hull › Hull Plating
Issued 4 February 2009 Resolved
Provide repair proposal for aft section of vessel wing area.
Action required: 705 - Other - as specified
Resolved 24 February 2009
Resolution: Provided satisfactory repair proposal and made proper repairs in accordance with the plans (see activity documents).
Construction/Loadline › Hull › Hull Plating
Issued 4 February 2009 Resolved
Damage located to FRP in way of cages approx. 10' aft of stem. Grind to good glass and repair as necessary.
Action required: 705 - Other - as specified
Resolved 24 February 2009
Resolution: Damaged areas ground to good area and repaired.
Construction/Loadline › Hull › Hull Plating
Issued 4 February 2009 Resolved
Damage to FRP (4'X4') 3 ft from stern & 3 ft below gunwale on aft port outboard side. Grind down to good glass and repair as necessary
Action required: 705 - Other - as specified
Resolved 24 February 2009
Resolution: Damaged area gound to good area. No significate damage found.
Engineering › Generator (propulsion/auxiliary-electric) › Wiring
Issued 4 February 2009 Resolved
Make changes from generator swap out in accordance with previously submitted proposal.
Action required: 705 - Other - as specified
Resolved 1 May 2009
Resolution: Witnessed proper installation and operation of generator.
Construction/Loadline › Hull › Longitudinal Frame
Issued 4 February 2009 Resolved
Determine extent of wood rot /damage throughout the interior of the vessel. Complete list of locations found with wood rot is in the narrative.
Action required: 705 - Other - as specified
Resolved 1 May 2009
Resolution: All wood rot repaired.
Construction/Loadline › Hull › Hull Plating
Issued 4 February 2009 Resolved
In presence of Coast Guard inspector, pull vessel fasteners from 16 locations indicated by Coast Guard.
Action required: 705 - Other - as specified
Resolved 5 February 2009
Resolution: Witnessed pulling of 16 fasteners. See results in narrative.
Construction/Loadline › Structures › Superstructure
Issued 4 February 2009 Resolved
Make closet by mens head available for inspections.
Action required: 705 - Other - as specified
Resolved 24 February 2009
Resolution: Closet made available for inspection and damaged areas repaired.
Construction/Loadline › Structures › Scuttle
Issued 4 February 2009 Resolved
Dry out/remove water from port aft space and make available for inspection.
Action required: 705 - Other - as specified
Resolved 16 March 2009
Resolution: Space was dried out and no deficiencies noted.
Construction/Loadline › Structures › Machinery Space Opening
Issued 4 February 2009 Resolved
Repair ladder for access to port fuel tank space.
Action required: 705 - Other - as specified
Resolved 16 March 2009
Resolution: Placed additonal support screws through ladder to frames.
Engineering › Bilge Water Management System › Valve
Issued 4 February 2009 Resolved
Replace missing/non-functional valve handles on bilge manifold in stbd engine room space.
Action required: 705 - Other - as specified
Due 6 March 2009
Resolved 1 May 2009
Resolution: Valve handles replaced.
Electrical › Electrical Distribution System (service) › Wiring
Issued 4 February 2009 Resolved
Remove deadend wires in stbd forward compartment in wing area b/w frames 10 & 12.
Action required: 705 - Other - as specified
Due 6 March 2009
Resolved 16 March 2009
Resolution: Deadend wires removed from compartment.
Electrical › Electrical Distribution System (service) › Cable
Issued 4 February 2009 Resolved
Hard wire battery charger power supply in MSD compartment.
Action required: 705 - Other - as specified
Due 6 March 2009
Resolved 16 March 2009
Resolution: Vessel rep opted to remove battery charger completely since alternator supplies adequate power.
Engineering › Freshwater Generation System › Pump
Issued 4 February 2009 Resolved
Properly secure/mount MSD & potable water pumps.
Action required: 705 - Other - as specified
Due 6 March 2009
Resolved 16 March 2009
Resolution: Both pumps are properly secured.
Electrical › Electrical Distribution System (service) › Wiring
Issued 4 February 2009 Resolved
Remove deadend wires in MSD space next to water pump & inboard of sewage tank.
Action required: 705 - Other - as specified
Due 6 March 2009
Resolved 16 March 2009
Resolution: All deadend wires removed from MSD space.
Engineering › Fuel Oil Service System › Filter
Issued 4 February 2009 Resolved
Repair leak to stbd side fuel filter & remove all liquid from bilge.
Action required: 705 - Other - as specified
Due 6 March 2009
Resolved 16 March 2009
Resolution: Tightened bottom nut on fuel filter which secured leak.
Accommodation/Occupational Safety › Occupational Safety › Guards for Exposed Hazards
Issued 4 February 2009 Resolved
Provide belt guards at port and stbd fire pumps to prevent personnel injuries.
Action required: 705 - Other - as specified
Due 6 March 2009
Resolved 16 March 2009
Resolution: Determined that belt guards were not necessary.
Engineering › Freshwater System (jacketwater cooling) › Piping
Issued 4 February 2009 Resolved
Replace wasted water cooling pipe on stbd engine forward of water pump.
Action required: 705 - Other - as specified
Due 6 March 2009
Resolved 16 March 2009
Resolution: Sanded off rust/corrosion from pipe and determined that adequate metal still remained.
Engineering › Steering Gear System › Chain
Issued 4 February 2009 Resolved
Make necessary arrangements to prevent stbd steering cable from chaffing/binding on hull.
Action required: 705 - Other - as specified
Due 6 March 2009
Resolved 16 March 2009
Resolution: Adequate arrangements made to prevent further chaffing.
Electrical › Electrical Distribution System (service) › Wiring
Issued 4 February 2009 Resolved
Remove deadend wires in aft closet space below operation station.
Action required: 705 - Other - as specified
Due 6 March 2009
Resolved 24 February 2009
Resolution: Dead end wires removed.
Electrical › Electrical Distribution System (service) › Wiring
Issued 4 February 2009 Resolved
Properly secure unsupported wires in MSD space overhead on stbd side.
Action required: 705 - Other - as specified
Due 6 March 2009
Resolved 16 March 2009
Resolution: Wires in MSD space properly secured.
Electrical › Electrical Distribution System (service) › Metallic Enclosure/Frame
Issued 4 February 2009 Resolved
Replace wasted conduit hangers in MSD space (15th frame) stbd side and stbd engine room space.
Action required: 705 - Other - as specified
Due 6 March 2009
Resolved 16 March 2009
Resolution: Conduit hangers replaced.
Engineering › Sea-water System (primary cooling) › Valve
Issued 4 February 2009 Resolved
Make all valves below the water line available for inspection.
Action required: 705 - Other - as specified
Resolved 5 February 2009
Resolution: Conducted satisfactory inspection of all valves below the water line.
Construction/Loadline › Structures › Deck Plating
Issued 4 February 2009 Resolved
Make repairs to port roof engine hatch forward edge and repair/replace hardware on stbd side hatch.
Action required: 705 - Other - as specified
Due 6 March 2009
Resolved 16 March 2009
Resolution: Proper repairs completed to port and stbd roof engine hatches.
Electrical › Electrical Distribution System (service) › Wiring
Issued 4 February 2009 Resolved
Properly secure wires on outboard side of port fuel tank space.
Action required: 705 - Other - as specified
Due 6 March 2009
Resolved 24 February 2009
Resolution: Wires properly repaired.
Engineering › Fuel Oil Service System › Hose
Issued 4 February 2009 Resolved
Replace crimped hose for supply of port engine fuel tank.
Action required: 705 - Other - as specified
Due 6 March 2009
Resolved 1 May 2009
Resolution: Hose replaced with new hose.
Construction/Loadline › Structures › Superstructure
Issued 4 February 2009 Resolved
Make repairs to benches on port side.
Action required: 705 - Other - as specified
Due 6 March 2009
Resolved 24 February 2009
Resolution: Proper repairs made to benches.
Electrical › Electric Generation Source (service) › Generator
Issued 10 December 2008 Resolved
New generator installed approx 1 week ago without Coast Guard approval. The following information is required: Plans and specifications for generator change out to include modifications to electrical, fuel, exhaust, salt water systems and engine mounts. Also include engine weight, make, model, HP and serial number. Include generator make, model, rated AMPS, KW and voltage.
Action required: 705 - Other - as specified
Due 9 January 2009
Resolved 12 March 2009
Resolution: Vessel provided all required documentation. Witnessed proper installation of generator IAW provided plans.
Pollution Prevention/Response › Prevention Equipment › Fixed Containment
Issued 10 December 2008 Resolved
Remove all excess oil from port and stbd engine compartments and clean surrounding areas.
Action required: 705 - Other - as specified
Resolved 11 December 2008
Resolution: All excess oil has been removed from engine compartments.
Construction/Loadline › Hull › Hull Plating
Issued 20 May 2008 Resolved
Located hole in side of vessel protruding inside with 2 broken stringers. Submit a repair plan for hole in port aft hull in steering compartment.
Condition: Damaged By Earlier Event
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 30 June 2008
Resolution: Completed satisfactory repairs to hole located in port, aft hull.
Fire Fighting › Fixed Gas Fire Extinguishing System › Operating Controls
Issued 20 May 2008 Resolved
Generator would not shut down while conducting test of fixed fire system. Prove proper operation of generator fixed fire system shutdowns.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 30 June 2008
Resolution: Proved proper operation of generator fixed fire system shutdowns.
Fire Fighting › Portable CO2 Fire Extinguisher › Condition
Issued 20 May 2008 Resolved
Provide one B-I fire extinguisher for the operating station.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 30 June 2008
Resolution: Provided necessary B-I fire extinguisher for operating station.
Fire Fighting › Fixed Gas Fire Extinguishing System › Operating Controls
Issued 20 May 2008 Resolved
During test of fixed fire system for port & stbd engine room, visual alarm was not operable. Prove proper operation of visual alarm for port & stbd engine fixed fire system shutdown.
Action required: 705 - Other - as specified
Due 7 July 2008
Resolved 16 July 2008
Resolution: Tested operation of new alarm indicator/override switch on both propulsion engines. All sat.
Engineering › Diesel Engine (auxiliary) › Piping (exhaust)
Issued 20 May 2008 Resolved
While conducting an operational test of the generator, the small space filled with exhaust and was not safe for entry. Make repairs to generator exhaust system.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 30 June 2008
Resolution: Made satisfactory repairs to vessel''s generator exhaust system.
Lifesaving › Lifejacket/PFD (General) › Retroreflective Material
Issued 20 May 2008 Resolved
Provide 6 additional adult life jackets with proper retro reflective material.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 30 June 2008
Resolution: Provided 6 life jackets with proper operation.
Fire Fighting › Fixed Gas Fire Extinguishing System › Operating Controls
Issued 20 May 2008 Resolved
Provide labels for fixed fire system remote pulls and bezel to identify associated equipment.
Action required: 705 - Other - as specified
Due 30 June 2008
Resolved 30 June 2008
Resolution: Properly labeled fixed fire system remote pulls and bezel.
Navigation › Piloting/Steering › Marine Charts
Issued 20 May 2008 Resolved
Provide charts for Mamala Bay and Kaneohe Bay of proper scale for safe navigation.
Action required: 705 - Other - as specified
Due 30 June 2008
Resolved 30 June 2008
Resolution: Provided appropriate charts of Mamala Bay & Kaneohe Bay.
Accommodation/Occupational Safety › Other Accommodation Spaces › Recreation Space
Issued 20 May 2008 Resolved
Make bar and service area clean and in a sanitary condition.
Action required: 705 - Other - as specified
Due 30 June 2008
Resolved 30 June 2008
Resolution: Cleaned bar and service area, now in sanitary condition.
Lifesaving › Lifejacket/PFD (Type I) › Retroreflective Material
Issued 11 October 2007 Resolved
Renew retroreflective material on life jackets
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 25 October 2007
Resolved 25 October 2007
Communications › Alarms/Indicators › Bilge Alarm
Issued 11 October 2007 Resolved
Provide a high level bilge alarm visual indicator IAW 46 CFR 185.530(a)
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 25 October 2007
Resolved 25 October 2007
Resolution: Renewed alarm indicators on operating station. Test Sat.
Communications › Public Address System › Announcing Station
Issued 11 October 2007 Resolved
Provide a public address system for the vessel
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 25 October 2007
Resolved 25 October 2007
Resolution: Battery operated bullhorn provided for vessel.
Engineering › Fuel Oil Service System › Hose
Issued 11 October 2007 Resolved
Renew generator fuel supply and return hoses.
Condition: Unknown
Action required: 705 - Other - as specified
Due 25 October 2007
Resolved 25 October 2007
Resolution: Both fuel hoses renewed.
Engineering › Diesel Engine (propulsion/auxiliary-electric) › Piping (exhaust)
Issued 11 October 2007 Resolved
Renew generator exhaust discharge flex hose.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 25 October 2007
Resolved 25 October 2007
Resolution: All exhaust hoses renewed.
Electrical › Electrical Distribution System (service) › Panelboard
Issued 11 October 2007 Resolved
Provide cover for interior panel to electrical distribution switchboard.
Action required: 705 - Other - as specified
Due 25 October 2007
Resolved 1 November 2007
Resolution: New blank covers installed in panel to cover removed breakers.
Electrical › Electrical Distribution System (service) › Wiring
Issued 11 October 2007 Resolved
Repair electrical connections in both sewage compartments.
Action required: 705 - Other - as specified
Due 25 October 2007
Resolved 25 October 2007
Electrical › Electrical Distribution System (service) › Junction Box
Issued 11 October 2007 Resolved
Reinstall covers on electrical hunction boxes in both sewage compartments.
Action required: 705 - Other - as specified
Due 25 October 2007
Resolved 25 October 2007
Accommodation/Occupational Safety › Potable Water System › General
Issued 11 October 2007 Resolved
fix leaks in potable water pipes.
Action required: 705 - Other - as specified
Due 25 October 2007
Resolved 25 October 2007
Resolution: Replaced pipe and connections where leakage occured in Generator space
Communications › Alarms/Indicators › Bilge Alarm
Issued 11 October 2007 Resolved
Provide a visual indicator for automatic bilge pumps IAW 46CFR185.530(c)
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 25 October 2007
Resolved 25 October 2007
Resolution: Bilge pumps were determined not to be automatic as originally reported be vessel''s crew
Pollution Prevention/Response › Prevention Equipment › Sewage System Valve
Issued 11 October 2007 Resolved
Provide locking devices for sewage overboard valves.
Action required: 705 - Other - as specified
Due 25 October 2007
Resolved 25 October 2007
Resolution: Both sewage overboard valves locked close with seizing wire.
Engineering › Sea-water System (primary cooling) › Piping
Issued 31 May 2006 Resolved
Provide double clamps for all vital systems IAW 46CFR182.720
Condition: Unknown
Action required: 705 - Other - as specified
Due 20 June 2006
Resolved 20 June 2006
Resolution: Provided double clamps for all vital systems IAW 46CFR182.720
Lifesaving › Lifejacket/PFD (General) › Condition
Issued 31 May 2006 Resolved
Passenger count reduced to 134 passengers and 12 children IAW 46CFR181.410
Condition: Unknown
Action required: 705 - Other - as specified
Due 20 June 2006
Resolved 31 May 2006
Resolution: Vessel owner provided vessel with the appropriate number of new Life Jackets for adults and children
Construction/Loadline › Structures › Machinery Space Opening
Issued 31 May 2006 Resolved
Make starboard engine room vaportight IAW 46CFR181.410
Condition: Unknown
Action required: 705 - Other - as specified
Due 20 June 2006
Resolved 20 June 2006
Resolution: Made starboard engine room vaportight IAW 46CFR181.410
Accommodation/Occupational Safety › Medical/First Aid › Medicine Chest
Issued 31 May 2006 Resolved
Provide all required material for the first aid kit IAW 46CFR184.710
Condition: Unknown
Action required: 705 - Other - as specified
Due 20 June 2006
Resolved 20 June 2006
Resolution: Provided all required material for the first aid kit IAW 46CFR184.710
Fire Fighting › Means of Escape › Escape Route Signs
Issued 31 May 2006 Resolved
[name withheld] Escape (EMERGENCY EXIT KEEP CLEAR) 46CFR185.606
Condition: Unknown
Action required: 705 - Other - as specified
Due 20 June 2006
Resolved 20 June 2006
Resolution: Marked Emergency Escape (EMERGENCY EXIT KEEP CLEAR) 46CFR185.606
Stability › Weathertight Integrity › General
Issued 31 May 2006 Resolved
Provide securing devices for all hatches IAW 46CFR179.360
Condition: Unknown
Action required: 705 - Other - as specified
Due 20 June 2006
Resolved 20 June 2006
Resolution: Provided securing devices for all hatches IAW 46CFR179.360
Documentation › Certificates/Documents › Stability Letter
Issued 31 May 2006 Resolved
Provide stability letter for valid vessel
Condition: Unknown
Action required: 705 - Other - as specified
Due 20 June 2006
Resolved 12 June 2006
Resolution: Found vessel stability letter in case files for the vessel
Accommodation/Occupational Safety › Other Accommodation Spaces › Open Deck Space
Issued 31 May 2006 Resolved
Provide fixed seating IAW 46CFR177.820
Condition: Unknown
Action required: 705 - Other - as specified
Due 20 June 2006
Resolved 3 January 2007
Resolution: Vsl only has seating for 74 Passengers using deck area criteria, amended COI to reflect this.
Stability › Watertight Integrity › General
Issued 31 May 2006 Resolved
Provide plans for repairs to rotted areas located throughout the vessel. Submit marine surveyor report attesting to material condition of vessel IAW 46CFR176.700
Condition: Unknown
Action required: 705 - Other - as specified
Due 20 June 2006
Resolved 31 May 2006
Resolution: Provided plans for repairs to rotted areas located throughout the vessel. Submit marine surveyor report attesting to material condition of vessel IAW 46CFR176.700
Navigation › Collision/Grounding Avoidance
Issued 16 January 2003 Resolved
Prove proper operation of the port and starboard navigation lights. Vessel is restricted to day light operation only until repairs are completed to the satisfaction of the cognizant [name withheld]: Navigation Lights
Condition: Unknown
Action required: 705 - Other - as specified
Due 17 February 2003
Resolved 6 February 2004
Lifesaving › Lifejacket/PFD (General) › Condition
Issued 16 January 2003 Resolved
Condemned four PFD's due to broken chest strap retaining clip. Directed vessel master to remove affected PFD's from vessel.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 16 January 2003
Resolved 16 January 2003
Engineering › Diesel Engine (propulsion-reduction gear) › Piping (exhaust)
Issued 27 March 2002 Resolved
Remove duct tape from port and starboard engine exhaust for main engines. This must completed prior to operation with passengers.
Condition: Improper/Lack of Maintenance
Due 1 April 2002
Resolved 29 March 2002
Resolution: Vessel owner replace exhaust insulation.
Construction/Loadline › Hull › Bottom Plating
Issued 27 March 2002 Resolved
Replace through hull bolts on stabilizers on port and starboard hulls.
Condition: Improper/Lack of Maintenance
Due 1 April 2002
Resolved 29 March 2002
Resolution: Vessel owner replaced through hull bolts.
Construction/Loadline › Structures › Longitudinal Bulkhead
Issued 27 March 2002 Resolved
Repair or replace longitudinals 9 through 13 from top of compartment.
Condition: Improper/Lack of Maintenance
Due 1 April 2002
Resolved 3 April 2002
Resolution: Vessel owner repaired longitudinals.
Construction/Loadline › Structures
Issued 27 March 2002 Resolved
Repair or replace forward top and bottom potable water tank supports in #2 compartment starboard side. LEGACY COMPONENT DESC: Potable water tank supports
Condition: Improper/Lack of Maintenance
Due 1 April 2002
Resolved 3 April 2002
Resolution: Vessel owner replaced the tank supports.
Construction/Loadline › Structures
Issued 27 March 2002 Resolved
Repair or replace rotted #2 frame aft of collision bulkhead in #1 compartment. LEGACY COMPONENT DESC: Frame
Condition: Improper/Lack of Maintenance
Due 1 April 2002
Resolved 3 April 2002
Resolution: Vessel owner replace rotted #2 frame.
Construction/Loadline › Structures
Issued 27 March 2002 Resolved
Address rot in aft section of compartment #1 upper outboard side.
Due 1 April 2002
Resolved 29 March 2002
Resolution: Vessel owner had rotted area taken to good wood and preservative applied.
Construction/Loadline
Issued 12 October 2001 Resolved
Repair holes in fwd engineroom bulkhead. Item corrected on the spot.
Condition: Unknown
Due 18 October 2001
Resolved 18 October 2001
Accommodation/Occupational Safety
Issued 3 July 2000 Resolved
Make permanant repair to rail/gate on starboard bow IAW 46CFR 177.900.
Condition: Unknown
Due 19 July 2000
Resolved 19 July 2000
Electrical
Issued 3 July 2000 Resolved
Replace light removed from port engine compartment with properly protected light IAW 46CFR 183.410.
Condition: Unknown
Due 19 July 2000
Resolved 19 July 2000
Electrical
Issued 3 July 2000 Resolved
Replace battery charger in port fuel tank compartment due to severe deterioration of cabinet IAW 46CFR 183.220.
Condition: Unknown
Due 19 July 2000
Resolved 19 July 2000
Electrical
Issued 3 July 2000 Resolved
Replace port battery box cover to provide a more weathertight seal IAW 46CFR 183.350.
Condition: Unknown
Due 19 July 2000
Resolved 19 July 2000
Fire Fighting
Issued 3 July 2000 Resolved
Replace required marking/stenciling removed or painted over during course of drydock work, including remote fuel cut-off labels and life jacket stowage markings IAW 46CFR 185.612, 185.604 and 185.608.
Condition: Unknown
Due 19 July 2000
Resolved 19 July 2000
Engineering
Issued 3 July 2000 Resolved
Provide specifications (dimensions, scantling, weight), of new fuel tank for starboard main engine.
Condition: Unknown
Due 19 July 2000
Resolved 19 July 2000
Lifesaving
Issued 3 July 2000 Resolved
Prove proper operation of installed public address system IAW 46CFR 184.610.
Condition: Unknown
Due 19 July 2000
Resolved 19 July 2000
Construction/Loadline
Issued 3 July 2000 Resolved
Mark vessel stern and bow IAW 46CFR 67.123(a) and (d).
Condition: Unknown
Due 19 July 2000
Resolved 19 July 2000
Lifesaving
Issued 3 July 2000 Resolved
Replace floorboards over (port) engine compartment shaft and bilges IAW 46CFR 177.960.
Condition: Unknown
Due 19 July 2000
Resolved 19 July 2000
Construction/Loadline
Issued 3 July 2000 Resolved
Prove satisfactory operation of starboard bilge alarm, (indicator sounds weak and light is barely visible), IAW 46CFR 182.530.
Condition: Unknown
Due 19 July 2000
Resolved 19 July 2000
Fire Fighting
Issued 28 December 1999 Resolved
Provide means of mechanically closing vents to spaces protected by fixed gas fire extinguishing system iaw 46CFR 182.465(h).
Condition: Unknown
Due 28 December 1999
Resolved 28 December 1999
Electrical
Issued 14 December 1999 Resolved
Remove wire runs attached to PVC pipe with wire ties and install with metalsupports spaced not more than 24 inches apart iaw 46CFR 183.340(b)(4).
Condition: Unknown
Due 14 December 1999
Resolved 14 December 1999
Fire Fighting
Issued 14 December 1999 Resolved
Make bulkhead penetrations in spaces containing fixed gas fire fighting systems vapor tight iaw 46CFR 182.465(h).
Condition: Unknown
Due 29 December 1999
Resolved 29 December 1999
Engineering
Issued 14 December 1999 Resolved
Replace 30X30 mesh screen for port fuel tank iaw 46CFR 182.450(e).
Condition: Unknown
Due 29 December 1999
Resolved 29 December 1999
Lifesaving
Issued 14 December 1999 Resolved
Properly mark life jacket stowage areas with type and number of life jackets held iaw 46CFR 185.604(f).
Condition: Unknown
Due 29 December 1999
Resolved 29 December 1999
Lifesaving
Issued 14 December 1999 Resolved
Replace (1) adult life jacket to bring total aboard to 141. Passengers restricted to 137 until satisfied. 46CFR 180.71.
Condition: Unknown
Due 29 December 1999
Resolved 29 December 1999
Construction/Loadline
Issued 14 December 1999 Resolved
Complete installation of bilge alarm system iaw 46CFR 182.520.
Condition: Unknown
Due 29 December 1999
Resolved 29 December 1999
Construction/Loadline
Issued 14 December 1999 Resolved
Demonstrate proper operation of bilge pump in port lazzarette iaw 46CFR 182.520.
Condition: Unknown
Due 29 December 1999
Resolved 29 December 1999
Documentation
Issued 14 December 1999 Resolved
Provide current FCC Safety Radio Certificate iaw 46CFR 184.502.
Condition: Unknown
Due 29 December 1999
Resolved 29 December 1999
Unknown
Issued 15 October 1998 Resolved
Potable water pump was leaking form hose clamp. Stop leak in potable waterpump hosing.
Condition: Unknown
Due 19 October 1998
Resolved 19 October 1998
Electrical
Issued 15 October 1998 Resolved
Remove water from battery containers.
Condition: Unknown
Due 19 October 1998
Resolved 19 October 1998
Lifesaving
Issued 15 October 1998 Resolved
Remove/replace child's lifejacket with broken clip.
Condition: Unknown
Due 19 October 1998
Resolved 19 October 1998
Electrical
Issued 15 October 1998 Resolved
Replace wire nuts with pressure connectors at stbd potable water pump and port bilge pump/alarm.
Condition: Unknown
Due 19 October 1998
Resolved 19 October 1998
Electrical
Issued 15 October 1998 Resolved
Remove unused electrical wires in port and stbd forward compartments and inbattery room.
Condition: Unknown
Due 19 October 1998
Resolved 19 October 1998
Documentation
Issued 6 April 1998 Resolved
Provide plans of new 70 gallon diesel fuel tank construction.
Condition: Unknown
Due 6 May 1998
Resolved 13 April 1998
Documentation
Issued 6 April 1998 Resolved
Provide proof of current radio station license.
Condition: Unknown
Due 6 April 1998
Resolved 6 April 1998
Electrical
Issued 11 December 1996 Resolved
INSTALL COVERS ON ELECTRICAL JUNCTION BOXES IN THE EQUIPMENT LOCKER_x001C_ ON THE AFT DECK. 46 CFR 183.05-50
Condition: Unknown
Due 11 December 1996
Resolved 11 December 1996
Engineering
Issued 11 December 1996 Resolved
DEMONSTRATE PROPER OPERATION OF REMOTE FUEL SHUTOFF FOR PORT ENGINE FUEL TANK. 46 CFR 182.20-40(b)(3)
Condition: Unknown
Due 11 December 1996
Resolved 11 December 1996
Electrical
Issued 11 December 1996 Resolved
REMOVE OR PROPERLY SECURE DEAD END WIRES BEHIND CONTROL CONSOLE, IN GENERATOR ROOM, IN STBD FUEL TANK SPACE, AND IN BOTH ENGINE ROOMS._x001C_ 46 CFR 183.05-50
Condition: Unknown
Due 11 December 1996
Resolved 11 December 1996
Construction/Loadline
Issued 5 June 1996 Resolved
1. Starboard pontoon, second compartment aft of the bow, repair wood rot located just forward of the 4th aft vertical inboard frame and the 4th & 5th horizontal frame from the floor.
Condition: Unknown
Due 5 June 1996
Resolved 5 June 1996
Construction/Loadline
Issued 5 June 1996 Resolved
2. Starboard pontoon, second compartment aft of the bow, repair wood rot located just forward of the 4th aft vertical outboard frame and the 6th horizontal frame from the floor.
Condition: Unknown
Due 5 June 1996
Resolved 5 June 1996
Accommodation/Occupational Safety
Issued 5 June 1996 Resolved
3. Remove the MSD overboard discharge valves, reconnect vent pipes and provide 20x20 mesh flame screens at the vent pipe openings.
Condition: Unknown
Due 5 June 1996
Resolved 5 June 1996
Accommodation/Occupational Safety
Issued 5 June 1996 Resolved
4. Replace wasted exhaust vent pipe in port engine room, forward and inboard of the engine.
Condition: Unknown
Due 5 June 1996
Resolved 5 June 1996
Electrical
Issued 5 June 1996 Resolved
5. Disconnect all electrical, exhaust, cooling water and fuel connections from both unused generators. Properly cap overboard & fuel piping connections & dead end all electrical wiring not in use.
Condition: Unknown
Due 5 June 1996
Resolved 5 June 1996
Construction/Loadline
Issued 5 June 1996 Resolved
6. Port & stbd pontoon engine room overhead, make permanent repairs to wood rot, remove all angle hair rot & treat adjacent areas. Replace rottedwood with same material.
Condition: Unknown
Due 5 June 1996
Resolved 5 June 1996
Accommodation/Occupational Safety
Issued 5 June 1996 Resolved
7. Repair cracks bulwark on the port side in way of opening just forward of the deck house.
Condition: Unknown
Due 5 June 1996
Resolved 5 June 1996
Fire Fighting
Issued 5 June 1996 Resolved
8. Remove the empty B-II portable fire extinguisher, have it properly serviced.
Condition: Unknown
Due 5 June 1996
Resolved 5 June 1996
Lifesaving
Issued 26 October 1995 Resolved
PROVIDE SEVEN ADDITIONAL SERVICEABLE ADULT PFDs. THE TOTAL NUMBER OF PERSONS ALLOWED IS REDUCED TO 145 UNTIL THIS ITEM IS COMPLETED.
Condition: Unknown
Due 26 October 1995
Resolved 26 October 1995
Fire Fighting
Issued 26 October 1995 Resolved
ADJUST THE FIRE EXTINGUISHER BRACKETS IN THE PORT AND STARBOARD ENGINE ROOMS AND THE AFT LOCKER UNDER THE STEERING STATION.
Condition: Unknown
Due 26 October 1995
Resolved 26 October 1995
Engineering
Issued 26 October 1995 Resolved
PROVIDE ADDITIONAL LAGGING TO COVER THE STARBOARD ENGINE EXHAUST.
Condition: Unknown
Due 26 October 1995
Resolved 26 October 1995
Electrical
Issued 26 October 1995 Resolved
PROPERLY SECURE OR REMOVE THE DEAD END WIRES IN THE AFT STARBOARD HOLD.
Condition: Unknown
Due 26 October 1995
Resolved 26 October 1995
Electrical
Issued 26 October 1995 Resolved
PROVIDE COVERS FOR THE JUNCTION BOXES IN THE STARBOARD AFT HOLD AND PORT BATTERY ROOM.
Condition: Unknown
Due 26 October 1995
Resolved 26 October 1995
Engineering
Issued 26 October 1995 Resolved
PROPERLY REMOVE AND SECURE THE OLD OIL GAUGE LINE IN THE STARBOARD AFT VOID.
Condition: Unknown
Due 26 October 1995
Resolved 26 October 1995
Lifesaving
Issued 26 October 1995 Resolved
RENEW THE BATTERY FOR THE RING BUOY WATERLIGHT.
Condition: Unknown
Due 26 October 1995
Resolved 26 October 1995
Documentation
Issued 26 October 1995 Resolved
POST ORIGINAL CERTIFICATE OF INSPECTION.
Condition: Unknown
Due 26 October 1995
Resolved 26 October 1995
Electrical
Issued 26 October 1995 Resolved
PROVE OPERATION OF THE GENERATORS TO THE SATISFACTION OF THE COAST GUARD INSPECTOR, OR REMOVE.
Condition: Unknown
Due 26 October 1995
Resolved 26 October 1995
Documentation
Issued 26 October 1995 Resolved
UPDATE WASTE MANAGEMENT PLAN TO REFLECT CURRENT PERSON(S) IN CHARGE.
Condition: Unknown
Due 26 October 1995
Resolved 26 October 1995
Fire Fighting
Issued 26 October 1995 Resolved
SERVICE THE B-I EXTINGUISHER.
Condition: Unknown
Due 26 October 1995
Resolved 26 October 1995
Lifesaving
Issued 26 October 1995 Resolved
PROVIDE ONE ADDITIONAL SERVICEABLE CHILD-SIZE PFD. THE NUMBER OF PERSONS WEIGHING LESS THAN 90 POUNDS IS RESTRICTED TO 15 UNTIL COMPLETED.
Condition: Unknown
Due 26 October 1995
Resolved 26 October 1995
Lifesaving
Issued 3 March 1995 Resolved
Make permanent repairs to 47 adult PFDs by installing new reflective tape in way of the existing defective material. Vessel limited to not more than107 total persons until new tape is installed. Vessel needs to provide 1 additional child PFDs for a total of 16.
Condition: Unknown
Due 3 March 1995
Resolved 3 March 1995
Construction/Loadline
Issued 3 March 1995 Resolved
Modify the entrances into the void spaces for both pontoon, the bulwark andmain deck seat arrangements to eliminate the collection and drainage of fresh water in low spot on the main deck and drainage into the pontoon compartments.
Condition: Unknown
Due 3 March 1995
Resolved 3 March 1995
Engineering
Issued 3 March 1995 Resolved
Relocate the port and starboard emergency fuel oil tank shut off valves from outside the heads to allow crew access at all times in accordance with46 CFR 182.20-40(b)(3).
Condition: Unknown
Due 3 March 1995
Resolved 3 March 1995
Lifesaving
Issued 3 March 1995 Resolved
Relabel the PFD storage locations in accordance with 46 CFR 185.30-10.
Condition: Unknown
Due 3 March 1995
Resolved 3 March 1995
Construction/Loadline
Issued 6 January 1995 Resolved
REPLACE 3-WAY VALVE WITH ELBOW OR CAP OPEN END; PORT MSD SEA WATER SUCTION.
Condition: Unknown
Due 6 January 1995
Resolved 6 January 1995
Construction/Loadline
Issued 6 January 1995 Resolved
PORT PONTOON ENGINE ROOM OVERHEAD IN VICINITY OF AFT BULKHEAD REPAIR ROTTEDWOOD.
Condition: Unknown
Due 6 January 1995
Resolved 6 January 1995
Construction/Loadline
Issued 6 January 1995 Resolved
STB PONTOON, AFT COMPARTMENT JUST FWD OF STEERING POST, PORT SIDE OVERHEAD NEAR SIDE SHELL, REPAIR ROTTED WOOD.
Condition: Unknown
Due 6 January 1995
Resolved 6 January 1995
Construction/Loadline
Issued 6 January 1995 Resolved
PORT GENERATOR ROOM, PORT SIDE AFT BULKHEAD CORNER/OVERHEAD REPAIR ROTTED WOOD.
Condition: Unknown
Due 6 January 1995
Resolved 6 January 1995
Construction/Loadline
Issued 6 January 1995 Resolved
STB PONTOON ENGINE ROOM OVERHEAD, REPAIR ROTTED WOOD AND DELAMINATED FRP.
Condition: Unknown
Due 6 January 1995
Resolved 6 January 1995
Construction/Loadline
Issued 6 January 1995 Resolved
PORT PONTOON, PORT SIDE, JUST AFT OF ENGINE, OVERHEAD NEAR PORT LIGHT, REPAIR ROTTED WOOD.
Condition: Unknown
Due 6 January 1995
Resolved 6 January 1995
Construction/Loadline
Issued 6 January 1995 Resolved
PORT PONTOON, AFT STEERING COMPARTMENT, REPAIR OVERHEAD ROTTED WOOD.
Condition: Unknown
Due 6 January 1995
Resolved 6 January 1995
Electrical
Issued 6 January 1995 Resolved
PROPERLY SECURE ELECTRICAL JUNCTION BOX LOCATED ON AFT SIDE OF MAST AND REPAIR CRACKED CONDUIT.
Condition: Unknown
Due 6 January 1995
Resolved 6 January 1995
Engineering
Issued 6 January 1995 Resolved
REPAIR/REPLACE AS PER ORIGINAL CRACKED CHAIN PLATE STB SIDE, MOST FWD STAY PRIOR TO CARRING PASSENGERS.
Condition: Unknown
Due 9 January 1995
Resolved 9 January 1995
Lifesaving
Issued 6 January 1995 Resolved
REPAIR/REPLACE AS PER ORIGINAL TWO CRACKED LIFE LINE STANCHIONS AT FWD EMBARKATION LADDER.
Condition: Unknown
Due 6 January 1995
Resolved 6 January 1995
Engineering
Issued 6 January 1995 Resolved
REPAIR/REPLACE AS PER ORIGINAL CRACKED CHAIN PLATE PORT SIDE AFT PRIOR TO CARRING PASSENGERS.
Condition: Unknown
Due 9 January 1995
Resolved 9 January 1995
Construction/Loadline
Issued 6 January 1995 Resolved
REPAIR CRACKS IN FWD EMBARKATION LADDER PRIOR TO CARRING PASSENGERS.
Condition: Unknown
Due 9 January 1995
Resolved 9 January 1995
Construction/Loadline
Issued 6 January 1995 Resolved
REPAIR CRACKED HORIZONTAL STRENGTH MEMBER ON FWD METAL DECK, 3RD HORIZONTALAFT, CENTERLINE PRIOR TO CARRING PASSENGERS.
Condition: Unknown
Due 9 January 1995
Resolved 9 January 1995
Lifesaving
Issued 6 January 1995 Resolved
REPLACE ALL SEVERELY CORRODED PIPE/CONDUIT HOLDER AND HANGERS THROUGHOUT THE VSL.
Condition: Unknown
Due 6 January 1995
Resolved 6 January 1995
Engineering
Issued 6 January 1995 Resolved
REPLACE VENT PIPE IN PORT ENGINE ROOM, FWD OF ENGINE.
Condition: Unknown
Due 6 January 1995
Resolved 6 January 1995
Electrical
Issued 6 January 1995 Resolved
REPAIR/REPLACE ROTTED BATTERY BOX IN MSD COMPARTMENT.
Condition: Unknown
Due 6 January 1995
Resolved 6 January 1995
Construction/Loadline
Issued 6 January 1995 Resolved
STB PONTOON, AFT COMPARTMENT, REPAIR WOOD ROT TO OVERHEAD IN VICINITY OF FWD BULKHEAD.
Condition: Unknown
Due 6 January 1995
Resolved 6 January 1995
Electrical
Issued 6 January 1995 Resolved
REPLACE JUNCTION BOX (ELECTRICAL) IN STB ENGINE ROOM.
Condition: Unknown
Due 6 January 1995
Resolved 6 January 1995
Construction/Loadline
Issued 6 January 1995 Resolved
LABEL STB/PORT ENGINE ROOMS BILGE MANIFOLD VALVES TO CORRESPOND WITH POSTEDOPERATION INSTRUCTIONS.
Condition: Unknown
Due 6 January 1995
Resolved 6 January 1995
Electrical
Issued 28 October 1994 Resolved
REPLACE BROKEN GLOBE GLASS ON LIGHT FIXTURE LOCATED IN THE STARBOARD GENERATOR ROOM.
Condition: Unknown
Due 28 October 1994
Resolved 28 October 1994
Engineering
Issued 28 October 1994 Resolved
RENEW THE WASTED EXHAUST VENT DUCT LOCATED IN THE PORT MAIN ENGINE ROOM.
Condition: Unknown
Due 28 October 1994
Resolved 28 October 1994
Engineering
Issued 28 October 1994 Resolved
RENEW THE WASTED EXHAUST VENT DUCT LOCATED IN THE STARBOARD MAIN ENGINE ROOM.
Condition: Unknown
Due 28 October 1994
Resolved 28 October 1994
Lifesaving
Issued 28 October 1994 Resolved
PROPERLY REFASTEN LOOSE LADDER RUNG PADS, NON SKID DEVICES, AND REPLACE ONE(01) MISSING RUNG PAD ON THE FORWARD WATER ENTRY/EXIT LADDER.
Condition: Unknown
Due 28 October 1994
Resolved 28 October 1994
Construction/Loadline
Issued 28 October 1994 Resolved
PROVE PROPER OPERATION OF THE STARBOARD FIXED BILGE AND FIRE PUMP.
Condition: Unknown
Due 28 October 1994
Resolved 28 October 1994
Lifesaving
Issued 28 October 1994 Resolved
PROVIDE THREE(03) COAST GUARD APPROVED PFD'S TO REPLACE REJECTED PFD'S. VESSEL PASSENGER CARRYING CAPACITY REDUCED TO 132 UNTIL REPLACEMENT PFD'S ARE ONBOARD.
Condition: Unknown
Due 30 November 1994
Resolved 28 October 1994
Lifesaving
Issued 28 October 1994 Resolved
RENEW/REPLACE THREE(03) MOISTURE SOAKED ORANGE SMOKE VISUAL DISTRESS SIGNALS PRIOR TO SAILING WITH PASSENGERS.
Condition: Unknown
Due 30 November 1994
Resolved 28 October 1994
Accommodation/Occupational Safety
Issued 28 October 1994 Resolved
REPLACE MISSING VENT COWL FOR THE PORT GENERATOR ROOM.
Condition: Unknown
Due 28 October 1994
Resolved 28 October 1994
Electrical
Issued 28 October 1994 Resolved
PROPERLY COVER OPEN HOLES IN THE ELECTRICAL POWER PANEL LOCATED IN THE PORTGENERATOR ROOM.
Condition: Unknown
Due 28 October 1994
Resolved 28 October 1994
Accommodation/Occupational Safety
Issued 28 October 1994 Resolved
RENEW THE WASTED VENT DUCT AND REPLACE THE MISSING VENT COWL LOCATED IN COMPARTMENT #2 STARBOARD.
Condition: Unknown
Due 28 October 1994
Resolved 28 October 1994
Construction/Loadline
Issued 28 October 1994 Resolved
REPLACE MISSING VALVE HANDLE FOR BILGE ISOLATION VALVE TO STARBOARD FOREPEAK COMPARTMENT LOCATED IN COMPARTMENT #2 STARBOARD.
Condition: Unknown
Due 28 October 1994
Resolved 28 October 1994
Electrical
Issued 28 October 1994 Resolved
PROPERLY REMOUNT LOOSE/HANGING ELECTRICAL JUNCTION BOX AND INSTALL MISSING COVER ON LOWER MAIN MAST.
Condition: Unknown
Due 28 October 1994
Resolved 28 October 1994
Electrical
Issued 28 October 1994 Resolved
REPLACE BROKEN GLOBE GLASS ON THE LIGHT FIXTURE LOCATED IN THE STARBOARD MAIN ENGINE ROOM.
Condition: Unknown
Due 28 October 1994
Resolved 28 October 1994
Engineering
Issued 28 October 1994 Resolved
INSTALL MISSING EXHAUST PIPE INSULATION FOR THE STARBOARD MAIN ENGINE.
Condition: Unknown
Due 28 October 1994
Resolved 28 October 1994
Construction/Loadline
Issued 21 October 1993 Resolved
MAKE WATERTIGHT THE PORT LIGHTS LOCATED IN EACH ENGINE COMPARTMENT.
Condition: Unknown
Due 21 October 1993
Resolved 21 October 1993
Engineering
Issued 21 October 1993 Resolved
RENEW FUEL TANK VENT FLAME SCREENS WITH 30 X 30 STAINLESS STEEL OR BRONZE MESH.
Condition: Unknown
Due 21 October 1993
Resolved 21 October 1993
Accommodation/Occupational Safety
Issued 26 October 1992 Resolved
REPAIR OR REPLACE THE PORTLIGHTS IN THE PORT AND STBD FUEL TANK SPACES.
Condition: Unknown
Due 26 October 1992
Resolved 26 October 1992
Documentation
Issued 26 October 1992 Resolved
PROVIDE PROOF OF COMPLIANCE WITH THE MANDATORY RANDOM DRUG TESTING_x001C_ REQUIREMENTS (46 CFR 16.230).
Condition: Unknown
Due 26 October 1992
Resolved 26 October 1992
Fire Fighting
Issued 26 October 1992 Resolved
MAKE PERMANENT REPAIRS TO THE STARBOARD HULL FIRE MAIN IN WAY OF THE SOFT PATCH.
Condition: Unknown
Due 26 October 1992
Resolved 26 October 1992
Construction/Loadline
Issued 26 October 1992 Resolved
RENEW THE VENTILATION PIPING, WHERE WASTED, TO THE PORT HULL GENERATOR SPACE.
Condition: Unknown
Due 26 October 1992
Resolved 26 October 1992
Engineering
Issued 26 October 1992 Resolved
RENEW THE FLAME SCREENS ON THE FUEL TANK VENTS WITH 30X30 STAINLESS STEEL OR BRONZE MESH.
Condition: Unknown
Due 26 October 1992
Resolved 26 October 1992
Engineering
Issued 26 October 1992 Resolved
RENEW THE VENTILATION SCOOPS ON THE PORT HULL.
Condition: Unknown
Due 26 October 1992
Resolved 26 October 1992
Accommodation/Occupational Safety
Issued 26 October 1992 Resolved
RENEW THE PASSAGEWAY RAILING TO THE STERN SWIM STEP.
Condition: Unknown
Due 26 October 1992
Resolved 26 October 1992
Fire Fighting
Issued 1 May 1992 Resolved
INSTALL IAW COI USCG APPROVED BII FIRE EXTINGUISHER, STBD SIDE FORWARD.
Condition: Unknown
Due 1 May 1992
Resolved 1 May 1992
Fire Fighting
Issued 1 May 1992 Resolved
RELOCATE BII FIRE EXTINGUISHER TO AN ACCESSIBLE LOCATION.
Condition: Unknown
Due 1 May 1992
Resolved 1 May 1992
Engineering
Issued 1 May 1992 Resolved
REPAIR BROKEN FUEL SHUT OFF CABLES TO RIGHT GENERATOR TANK AND LEFT MAIN FUEL TANK.
Condition: Unknown
Due 1 May 1992
Resolved 1 May 1992
Engineering
Issued 25 October 1991 Resolved
Prove operation of remoted fuel shut offs for the generator fuel tank and the main fuel tank.
Condition: Unknown
Due 1 November 1991
Resolved 2 November 1991
Lifesaving
Issued 25 October 1991 Resolved
Provide 6 additional adult PFD's. Total allowed on board is reduced to 132until compliance.
Condition: Unknown
Due 1 November 1991
Resolved 2 November 1991
Electrical
Issued 26 October 1989 Resolved
PROVIDE ELECTRICAL SCHEMETIC SHOWING WIRING AS INSTALLED ON VESSEL.
Condition: Unknown
Due 26 October 1989
Resolved 26 October 1989
Construction/Loadline
Issued 26 October 1989 Resolved
SUPPLY LIST OF PORT AND STBD HULL REPAIRS (IE SISTERED FRAMES, FASTENINGS, ETC.), IN PROPOSED CHRONOLOGICAL ORDER OR REPAIR, AND A LIST OF THOSE ITEMSCOMPLETED.
Condition: Unknown
Due 26 October 1989
Resolved 26 October 1989
Electrical
Issued 26 October 1989 Resolved
PROVIDE ELECTRICAL SCHEMATIC FOR PROPOSED WIRING OF VESSEL IN ACCORDANCE WITH 46 CFR 183 WITH SUPPORTING DATA ON MATERIALS.
Condition: Unknown
Due 26 October 1989
Resolved 26 October 1989
Construction/Loadline
Issued 11 May 1989 Resolved
VESSEL IS TO PROCEED UNDER ESCORT TO A SUITABLE DRYDOCK FACILITY ON OAHU. UPON ARRIVAL IN OAHU, CONTACT THE OFFICER IN CHARGE MARINE INSPECTION HONOLULU, HI TO SCHEDULE A DAMAGE SURVEY AND A CREDIT DRYDOCK INSPECTION. VESSEL IS PROHIBITED FROM CARRYING PASSENGERS UNTIL ABOVE REQ. ARE COMPLETE
Condition: Unknown
Due 11 May 1989
Resolved 11 May 1989
Navigation
Issued 11 October 1988 Resolved
RENEW PORT STEERING CABLE TRANSOM SHEEVE.
Condition: Unknown
Due 11 October 1988
Resolved 11 October 1988
Engineering
Issued 11 October 1988 Resolved
RENEW PORT MAIN ENGINE EXHAUST LAGGING.
Condition: Unknown
Due 11 October 1988
Resolved 11 October 1988
Engineering
Issued 11 October 1988 Resolved
REPLACE FLEX HOSE TRANSITIONS ON PIRT FIRE/BILGE PUMP.
Condition: Unknown
Due 11 October 1988
Resolved 11 October 1988
Engineering
Issued 11 October 1988 Resolved
REPLACE WITH RIGID PIPE, THE FLEX HOSE "90" TRANSITION LEADING TO STARBOARDBILGE MANIFOLD.
Condition: Unknown
Due 11 October 1988
Resolved 11 October 1988
Electrical
Issued 11 October 1988 Resolved
PROVIDE PROTECTIVE COVER FOR ELECTRICAL CONNNECTOR STRIPS ABOVE PORT FIRE/ BILGE PUMP.
Condition: Unknown
Due 11 October 1988
Resolved 11 October 1988
Electrical
Issued 11 October 1988 Resolved
PROPERLY SPLICE OR BUTT CONNECT PORT FRESH WATER TRANSFER PUMP ELECTRICAL CONNECTION.
Condition: Unknown
Due 11 October 1988
Resolved 11 October 1988
Engineering
Issued 11 October 1988 Resolved
REMOVE STANDING OILY WSTES FROM PORT AND STARBOARD MACHINERY SPACES.
Condition: Unknown
Due 11 October 1988
Resolved 11 October 1988
Engineering
Issued 11 October 1988 Resolved
REMOVE OILY WASTES FROM PORT AND STARBOARD MAIN ENGINE DRIP PANS.
Condition: Unknown
Due 11 October 1988
Resolved 11 October 1988
Engineering
Issued 11 October 1988 Resolved
PROVIDE HANDLE FOR STARBOARD MAIN ENGINE SEA VALVE
Condition: Unknown
Due 11 October 1988
Resolved 11 October 1988
Fire Fighting
Issued 11 October 1988 Resolved
RENEW STARBOARD FIRE/BILGE PUMP IMPELLER AND DEMONSTRATE AN EFFECTIVE STREAM OF WATER
Condition: Unknown
Due 11 October 1988
Resolved 11 October 1988
Fire Fighting
Issued 11 October 1988 Resolved
MAKE WATERTIGHT FIRST THREADED FITTING FOLLOWING THE DISCHARGE OF THE PORT BILGE/FIRE PUMP.
Condition: Unknown
Due 11 October 1988
Resolved 11 October 1988
Lifesaving
Issued 11 October 1988 Resolved
ATTACH FLOAT FREE LINKS TO 10 MAN AND 12 MAN BUOYANT APPARTUS TO VESSEL.
Condition: Unknown
Due 11 October 1988
Resolved 11 October 1988
Lifesaving
Issued 11 October 1988 Resolved
RENEW 12 MAN BUOYANT APPARATUS FLOAT FREE LINK WITH ONE OF PROPER SIZE.
Condition: Unknown
Due 11 October 1988
Resolved 11 October 1988
Fire Fighting
Issued 11 October 1988 Resolved
PLACE ON BOARD VESSEL 3 BII AND 1 BI PORTABLE FIRE EXTINGUISHERS IN PROPER SERVICABLE CONDITION.
Condition: Unknown
Due 11 October 1988
Resolved 11 October 1988
Engineering
Issued 7 January 1988 Resolved
PROVIDE FLAME DEFLECTOR SHIELDS FOR RACOR FUEL FILTERS.
Condition: Unknown
Due 7 January 1988
Resolved 7 January 1988
Construction/Loadline
Issued 16 December 1987 Resolved
MAKE VESSEL AVAILABLE TO CONDUCT A CREDIT DRYDOCK EXAM.
Condition: Unknown
Due 16 December 1987
Resolved 16 December 1987
Construction/Loadline
Issued 16 December 1987 Resolved
PRIOR TO OPERATION, DRYDOCK VESSEL TO MAKE PERMANENT REPAIRS IN WAY OF THE DAMAGED STBD KEEL AND SHAFT. DAMAGE TO SURVEYED BY AN ATTENDING COAST GUARD INSPECTOR PRIOR TO COMMENCING REPAIRS.
Condition: Unknown
Due 16 December 1987
Resolved 16 December 1987
Lifesaving
Issued 11 October 1985 Resolved
MARK EACH BUOYANT APPARATUS WITH VESSEL'S NAME AND NUMBER OF PERSONS ALLOWED IN ACCORDANCE WITH 46 CFR 180.20-5.
Condition: Unknown
Due 11 October 1985
Resolved 11 October 1985
Lifesaving
Issued 11 October 1985 Resolved
SECURE EACH BUOYANT APPARATUS TO THE VESSEL BY A PAINTER AND A FLOAT FREE LINK IN ACCORDANCE WITH 46 CFR 180.20.
Condition: Unknown
Due 11 October 1985
Resolved 11 October 1985
Documentation
Issued 11 October 1985 Resolved
POST ON BOARD VESSEL USCG STABILITY LETTER IN ACCORDANCE WITH 46 CFR 185.12
Condition: Unknown
Due 11 October 1985
Resolved 11 October 1985
Lifesaving
Issued 11 October 1985 Resolved
PROVIDE EQUIPMENT FOR VESSEL'S BUOYANT APPARATUS IN ACCORDANCE WITH 46 CFR 180.15 I.E., LIFELINES, WATERLIGHTS, AND PAINTERS.
Condition: Unknown
Due 11 October 1985
Resolved 11 October 1985
Lifesaving
Issued 11 October 1985 Resolved
PROVIDE AN ADDITIONAL 19 ADULT LIFE JACKETS AND 5 CHILDREN'S LIFE JACKETS. THE TOTAL NUMBER OF PERSONS CARRIED IS RESTRICTED TO 119 UNTIL THESE ADDITIONAL JACKETS ARE PROVIDED.
Condition: Unknown
Due 11 October 1985
Resolved 11 October 1985
Lifesaving
Issued 11 October 1985 Resolved
REPLACE OR REPAIR VESSEL'S 5 BUOYANT APPARATUS SO AS TO PROVIDE PRIMARY LIFESAVING EQUIPMENT FOR NOT LESS THAN 69 PERSONS (50% OF PERSONS ALLOWED BY COI).
Condition: Unknown
Due 11 October 1985
Resolved 11 October 1985
Lifesaving
Issued 11 October 1985 Resolved
IDENTIFY AND MARK STORAGE AREA FOR 14 CHILDREN'S LIFE JACKETS.
Condition: Unknown
Due 11 October 1985
Resolved 11 October 1985
Unknown
Issued 11 October 1985 Resolved
DEMONSTRATE VESSEL'S FIRE PUMPS AND FIRE STATIONS.
Condition: Unknown
Due 11 October 1985
Resolved 11 October 1985
Engineering
Issued 11 October 1985 Resolved
REPAIR OR REPLACE THE RPM GAUGE AND WATER TEMPERATURE GAUGE FOR THE PORT ENGINE AND THE DRIVE TRAIN OIL PRESSURE GAUGE FOR THE STARBOARD ENGINE.
Condition: Unknown
Due 11 October 1985
Resolved 11 October 1985
Engineering
Issued 11 October 1985 Resolved
IDENTIFY AND LABEL FUEL SHUTOFF VALVES FOR PORT AND STARBOARD ENGINE FUEL TANKS.
Condition: Unknown
Due 11 October 1985
Resolved 11 October 1985
Construction/Loadline
Issued 11 October 1985 Resolved
INSTALL SECURING DEVICES FOR FLUSH DECK HATCH COVERS ON FORWARD HULLS, PORT AND STARBOARD. THIS ITEM IS REISSUED FROM 27NOV84.
Condition: Unknown
Due 11 October 1985
Resolved 11 October 1985
Engineering
Issued 11 October 1985 Resolved
CLEAN OIL FROM PORT AND STARBOARD MACHINERY SPACE BILGES. (THIS ITEM IS REISSUED FROM 27NOV84).
Condition: Unknown
Due 11 October 1985
Resolved 11 October 1985
Unknown
Issued 11 October 1985 Resolved
SUBMIT PLAN TO INSTALL ONE APPROVED AIR RECEIVED WITH ACCEPTABLE PIPING ANDRELIEF VALVE FOR AIR FLUSH SYSTEM IN INSTALLED MARINE SANITATION DEVICE. (THIS ITEM REISSUED FROM 14JAN85).
Condition: Unknown
Due 11 October 1985
Resolved 11 October 1985
Documentation
Issued 11 October 1985 Resolved
PROVIDE AND POST EMERGENCY INSTRUCTIONS IN ACCORDANCE WITH 46 CFR 185.25-1.
Condition: Unknown
Due 11 October 1985
Resolved 11 October 1985
Fire Fighting
Issued 11 October 1985 Resolved
SERVICE VESSEL'S 4 PORTABLE FIRE EXTINGUISHERS PRIOR TO 31OCT85 AND PROVIDEEACH WITH AN APPROVED MARINE BRACKET.
Condition: Unknown
Due 11 October 1985
Resolved 11 October 1985
Navigation
Issued 11 October 1985 Resolved
PROVIDE 3 ADDITIONAL HAND ORANGE SMOKE DISTRESS SIGNALS.
Condition: Unknown
Due 11 October 1985
Resolved 11 October 1985
Documentation
Issued 11 October 1985 Resolved
RENEW VESSEL'S FCC CERTIFICATE. (EXPIRED 04NOV84).
Condition: Unknown
Due 11 October 1985
Resolved 11 October 1985
Unknown
Issued 11 October 1985 Resolved
PROVIDE PORT COVERS AND SECURING/DOGGING DEVICES FOR ALL PORTS IN PORT AND STARBOARD HULLS.
Condition: Unknown
Due 11 October 1985
Resolved 11 October 1985
Accommodation/Occupational Safety
Issued 14 January 1985 Resolved
SUBMIT PLAN TO INSTALL ONE APPROVED AIR RECEIVER WITH ACCEPTABLE PIPING ANDRELIEF VALVE FOR AIR FLUSH SYSTEM IN INSTALLED MARINE SANITATION DEVICE.
Condition: Unknown
Due 14 January 1985
Resolved 14 January 1985
Construction/Loadline
Issued 27 November 1984 Resolved
CLEAN OIL FROM ALL MACHINERY SPACES.
Condition: Unknown
Due 27 November 1984
Resolved 27 November 1984
Electrical
Issued 27 November 1984 Resolved
PROPERLY SUPPORT ELECTRICAL CABLE CONDUIT IN STARBOARD ENGINE ROOM.
Condition: Unknown
Due 27 November 1984
Resolved 27 November 1984
Lifesaving
Issued 27 November 1984 Resolved
PROVIDE FLOAT FREE LINK FOR BUOYANT APPARATUSES.
Condition: Unknown
Due 27 November 1984
Resolved 27 November 1984
Electrical
Issued 27 November 1984 Resolved
PROPERLY WIRE AND SPLICE SPEAKER WIRES.
Condition: Unknown
Due 27 November 1984
Resolved 27 November 1984
Construction/Loadline
Issued 27 November 1984 Resolved
INSTALL SECURING DEVICES FOR FLUSH DECK HATCH COVERS FORWARD HULLS, PORT AND STARBOARD.
Condition: Unknown
Due 27 November 1984
Resolved 27 November 1984
Unknown
Issued 27 November 1984 Resolved
Unknown Component - Unknown Cause/Condition
Condition: Unknown
Due 27 November 1984
Resolved 27 November 1984
Lifesaving
Issued 27 November 1984 Resolved
THE VESSEL IS RESTRICTED TO THE CARRIAGE OF NO MORE THAN 120 TOTAL PERSONS UNTIL THE ADDITIONAL AMOUNTS OF LIFE PRESERVERS AS INDICATED ON VESSEL'S COI ARE PROVIDED.
Condition: Unknown
Due 27 November 1984
Resolved 27 November 1984
Electrical
Issued 27 November 1984 Resolved
PROPERLY HANG/SUPPORT ELECTRICAL BILGE PUMP WIRING IN PORT ENGINE ROOM.
Condition: Unknown
Due 27 November 1984
Resolved 27 November 1984
Engineering
Issued 27 November 1984 Resolved
MAKE PERMANENT REPAIRS TO PORT AND STARBOARD ENGINE EXHAUST PIPING.
Condition: Unknown
Due 27 November 1984
Resolved 27 November 1984
Electrical
Issued 27 November 1984 Resolved
REPLACE MISSING LIGHT FIXTURES AND GLOBES FROM MACHINERY SPACES.
Condition: Unknown
Due 27 November 1984
Resolved 27 November 1984
Engineering
Issued 27 November 1984 Resolved
PROPERLY SUPPORT STARBOARD ENGINE EXHAUST RISER.
Condition: Unknown
Due 27 November 1984
Resolved 27 November 1984
Unknown
Issued 27 November 1984 Resolved
INSTALL RIGID BILGE DISCHARGE PIPING FOR ALL ELECTRIC BILGE PUMPS WITH A CHECK VALVE IN THE LINE.
Condition: Unknown
Due 27 November 1984
Resolved 27 November 1984
Unknown
Issued 27 November 1984 Resolved
Unknown Component - Unknown Cause/Condition
Condition: Unknown
Due 27 November 1984
Resolved 27 November 1984
Accommodation/Occupational Safety
Issued 27 November 1984 Resolved
REPLACE MISSING LOWER LADDER RUNG TO CONTROL STATION.
Condition: Unknown
Due 27 November 1984
Resolved 27 November 1984

Ownership record