Records from 1981 to 2003. Most recent: inspection, 14 July 2003.
A report is not offered for this hull: Its record holds only 2 of the seven kinds of material a report is built from: inspections, deficiencies, operational controls, tow-unit appearances, casualty records, dimensions and documentation. That is a statement about the record, not about the vessel. Reports.
Inspection history · 45
14 July 2003
Administrative Inspection
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1846089
26 October 2002
Type not recorded
No type recorded · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 1697228
6 September 2002
COI Inspection · Hull Examination
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1673128
28 January 2002
Administrative Inspection
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1482013
29 October 2001
Deficiency Check
Physical examination · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 1075638
7 September 2001
Re-Inspection
Physical examination · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 1399716
3 May 2001
Type not recorded
No type recorded · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 769368
25 April 2001
Type not recorded
No type recorded · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 189281
6 September 2000
Hull Examination · COI Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1441722
10 December 1998
Administrative
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 809253
19 November 1998
COI Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1395053
2 September 1998
Administrative
Administrative · MSO PROVIDENCE · USCG Northeast District (CGD-NE) · Activity 797857
12 March 1998
Hull Examination
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1457546
22 October 1997
Re-Inspection
Physical examination · MSO PROVIDENCE · USCG Northeast District (CGD-NE) · Activity 777962
9 July 1997
Inclining Experiment
Physical examination · MSO PROVIDENCE · USCG Northeast District (CGD-NE) · Activity 1414830
23 April 1997
Deficiency Check
Physical examination · MSO PROVIDENCE · USCG Northeast District (CGD-NE) · Activity 1097182
31 March 1997
Administrative
Administrative · MSO PROVIDENCE · USCG Northeast District (CGD-NE) · Activity 1099302
29 October 1996
COI Inspection
Physical examination · MSO PROVIDENCE · USCG Northeast District (CGD-NE) · Activity 1164511
23 October 1996
Hull Examination
Physical examination · MSO PROVIDENCE · USCG Northeast District (CGD-NE) · Activity 853865
12 September 1996
Drydock Extension
Administrative · MSO PROVIDENCE · USCG Northeast District (CGD-NE) · Activity 1265690
6 October 1995
COI Inspection
Physical examination · MSO PROVIDENCE · USCG Northeast District (CGD-NE) · Activity 1186427
8 November 1994
Deficiency Check
Physical examination · MSO PROVIDENCE · USCG Northeast District (CGD-NE) · Activity 868429
18 October 1994
COI Inspection
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1411037
29 August 1994
Hull Examination
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1172654
3 August 1992
Administrative
Administrative · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1256462
9 June 1992
Administrative
Administrative · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 1268770
4 February 1992
Drydock Extension
Administrative · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 1258308
5 August 1991
COI Inspection
Physical examination · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 941880
14 August 1990
Hull Examination · COI Inspection
Physical examination · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 912052
25 October 1989
COI Inspection
Physical examination · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 1237101
16 May 1989
Hull Examination
Physical examination · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 1352458
28 October 1988
COI Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1203010
19 November 1987
COI Inspection · Hull Examination
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1005492
24 April 1987
Type not recorded
No type recorded · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1024603
23 December 1986
COI Inspection
Physical examination · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1335514
27 January 1986
Type not recorded
No type recorded · MSO Mobile · USCG Heartland District (CGD-H) · Activity 995171
26 December 1985
Initial Certification
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1294851
18 July 1985
Type not recorded
No type recorded · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1290892
23 July 1984
Type not recorded
No type recorded · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1282615
22 February 1984
Type not recorded
No type recorded · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 971910
23 August 1983
Type not recorded
No type recorded · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1278979
21 March 1983
Type not recorded
No type recorded · MSO Mobile · USCG Heartland District (CGD-H) · Activity 967716
29 September 1982
Type not recorded
No type recorded · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 965349
27 March 1982
Type not recorded
No type recorded · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1275256
2 April 1981
Type not recorded
No type recorded · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1273029
Engineering
Issued 7 September 2001
Resolved
Hydrostatically test fuel transfer hose in accordance with 33 CFR 156.170.
Condition: Unknown
Due 7 September 2001
Resolved 25 September 2001
Construction/Loadline
Issued 7 September 2001
Resolved
Demonstrate proper operation of forepeak bilge suction valve remote control.
Condition: Unknown
Due 7 September 2001
Resolved 25 September 2001
Engineering
Issued 7 September 2001
Resolved
DEMONSTRATE PILOTHOUSE CONTROL OF PORT SIDE MAIN ENGINE SHUTDOWN.
Condition: Unknown
Due 7 September 2001
Resolved 25 September 2001
Lifesaving
Issued 7 September 2001
Resolved
Provide on board First Aid kit in accordance with 46 CFR 184.710, either USCG approved or equivalent as detailed in 46 CFR 160.041-4. Provide local OCMI with copy of invoice.
Condition: Unknown
Due 7 September 2001
Resolved 7 September 2001
Lifesaving
Issued 7 September 2001
Resolved
Repair Public Address System and provide statement from Master attenting toits satisfactory operation.
Condition: Unknown
Due 7 September 2001
Resolved 7 September 2001
Electrical
Issued 22 October 1997
Resolved
INSTALL A DRIP SHIELD COVER FOR ELECTRICAL PANEL BOX LOCATED IN THE ENGINE ROOM.
Condition: Unknown
Due 22 October 1997
Resolved 22 October 1997
Lifesaving
Issued 23 April 1997
Resolved
Provide calculations to the satisfaction of the CG Marine Safety Center to verify lightship characteristics or conduct inclining test and forward results to the CG Marine Safety Center for approval. Vsl may not operate with additional deck cargo or use the installed A-frame until def is corr.
Condition: Unknown
Due 23 April 1997
Resolved 23 April 1997
Lifesaving
Issued 31 March 1997
Resolved
Provide calculations to CG Marine Safety Center to verify lightship characteristics. Calculations must be to the satisfaction of the Marine Safety Center.
Condition: Unknown
Due 31 March 1997
Resolved 31 March 1997
Documentation
Issued 29 October 1996
Resolved
CONDUCT AUDIT OF VESSEL'S DRUG TESTING PROGRAM.
Condition: Unknown
Due 1 November 1996
Resolved 30 October 1996
Fire Fighting
Issued 29 October 1996
Resolved
REFILL PORTABLE BII DRY CHEMICAL FIRE EXTINGUISHER.
Condition: Unknown
Due 29 October 1996
Resolved 30 October 1996
Lifesaving
Issued 29 October 1996
Resolved
CONDUCT UNDERWAY FIRE AND BOAT DRILLS.
Condition: Unknown
Due 1 November 1996
Resolved 30 October 1996
Documentation
Issued 6 October 1995
Resolved
SUBMIT CALULATIONS FOR NEWLY ADDED A-FRAME AND SAMLING CRANE TO THE MARINE SAFETY CENTER 400 7TH STREET, SW. WASHINGTON, DC 20590-0001 FOR ISSUANCE OFA NEW STABILIY LETTER TO REFLECT NEW DECK CARGO WEIGHT.
Condition: Unknown
Due 6 October 1995
Resolved 6 October 1995
Deck/Cargo
Issued 8 November 1994
Resolved
UPDATE VESSEL'S STABILITY DATA FOR NEWLY INSTALLED DAVIT CRANE LOCATED ON THE AFTER FREIGHT DECK. CRANE CURRENTLY LIMITED TO LIFTING WATER SAMPLING EQUIPMENT UNDER (600) POUNDS.
Condition: Unknown
Due 8 November 1994
Resolved 8 November 1994
Fire Fighting
Issued 18 October 1994
Resolved
CONDUCT FIRE AND RESCUE DRILL.
Condition: Unknown
Due 18 October 1994
Resolved 18 October 1994
Lifesaving
Issued 18 October 1994
Resolved
PROVIDE SUITABLE RESCUE PLATFORM/LADDER.
Condition: Unknown
Due 18 October 1994
Resolved 18 October 1994
Fire Fighting
Issued 18 October 1994
Resolved
DEMONSTRATE OPERATION OF WATER CANON.
Condition: Unknown
Due 18 October 1994
Resolved 18 October 1994
Lifesaving
Issued 18 October 1994
Resolved
PROVIDE FOR LOCAL [name withheld] - INFLATABLE LIFERAFT LOCATION.
Condition: Unknown
Due 18 October 1994
Resolved 18 October 1994
Engineering
Issued 18 October 1994
Resolved
DEMONSTRATE AIR RECEIVER RELIEF VALVE.
Condition: Unknown
Due 18 October 1994
Resolved 18 October 1994
Accommodation/Occupational Safety
Issued 18 October 1994
Resolved
REPLACE TOILET IN FORWARD HEAD.
Condition: Unknown
Due 18 October 1994
Resolved 18 October 1994
Construction/Loadline
Issued 29 August 1994
Resolved
PROVIDE FOR REVIEW A COPY OF GAUGING REPORT INCLUDING DIAGARAM _x001C_ OF ORIGINAL THICKNESS. TO BE TO THE SATSFACTION OF THE COGNIZANT OCMI.
Condition: Unknown
Due 9 September 1994
Resolved 24 October 1994