← All vessels
FREEDOM
Passenger (Inspected) · Passenger Ship class · Built 1970s · USCG Northeast District (CGD-NE) · Other hulls named FREEDOM
FREEDOM is a 1974 passenger vessel (inspected). The Coast Guard has recorded 92 inspections since 1984, most recently in October 2025, along with 327 deficiencies and 1 casualty investigation in 2002.
Records from 1984 to 2025. Most recent: inspection, 28 October 2025.
- Built
- 1974
- Last inspected
- 28 October 2025
- Documentation
- Valid · documentation file of 10 September 2026
- Deficiencies
- 327 recorded · 0 without a recorded resolution
- Controls
- None recorded without a removal date
- Casualties
- 1 investigation · 2002
Identity
559113
WYR2173
48095
Flag
UNITED STATES
367377380
Maury page id
psix-48095
Inspections, by type
…with no type recorded9
Years with a record
38 calendar years (1984–2025)
The 92 inspections in the strip above, split by the kind of activity the US
Coast Guard recorded. Years with a record are calendar years in which a record exists, not
years in service. What Maury does not do.
Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Passenger Ship class in Maury's sources begin in 1977.
Documentation record
Registered dimensions (L × B × D)96.2 ft × 40.0 ft × 8.7 ft
Registered tonnagegross 99 / net 67
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
BuilderALUMASHIP CORPORATION · JEANERETTE, LA, UNITED STATES · built 1974
Hull materialAluminum
PropulsionDiesel Reduction
Hull shapeNot recorded
Hull configurationNot recorded
Hailing portBOSTON, MA
Trade endorsementsCoastwise, unrestricted
DocumentationValid · issued 8 April 2026 · expires 30 April 2027
Service, as the file records itPassenger (Inspected)
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it99 - Regulatory (Subpart C or D), Gross Ton
67 - Regulatory (Subpart C or D), Net Ton
0 - Dead Weight, Ton
67 - Regulatory (Subpart C or D), Net Ton
0 - Dead Weight, Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 September 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.
Radio station licence
WYR2173MMSI 367377380 · active · compulsorily equipped · granted 1 September 2018, expires 22 September 2028
FCC Universal Licensing System ship-station file of 6 September 2026, matched to this hull on its
US Official Number. Status and dates are the file’s own. The licensee is not read from the file and is not shown.
A lapsed licence’s MMSI is still the number the vessel transmitted under while it was valid.
Inspection history · 92
28 October 2025
In-Service Inspection
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 8248748
17 March 2025
Deficiency Check · Internal Structural Exam · COI Inspection · Hull Examination
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 8096369
6 May 2024
Annual Inspection · Internal Structural Exam · Deficiency Check
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 7899767
26 April 2023
Deficiency Check · Annual Inspection · Administrative Inspection · Hull Examination · In-Service Inspection · Internal Structural Exam
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 7670305
31 October 2022
Internal Structural Exam · Drydock Extension
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 7586944
3 May 2022
Annual Inspection · Internal Structural Exam
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 7425865
6 May 2021
Deficiency Check · Annual Inspection
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 7191633
26 March 2020
Hull Examination · Deficiency Check
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 6949271
6 February 2020
MTSA Verification · COI Inspection · Deficiency Check
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 6901560
13 May 2019
MTSA Verification · Annual Inspection
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 6682780
12 September 2018
Administrative Inspection · Deficiency Check
Physical examination · Navigation Center · Activity 6538767
3 April 2018
Hull Examination · Deficiency Check
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 6384382
12 March 2018
Annual Inspection · MTSA Verification
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 6370068
19 June 2017
Type not recorded
No type recorded · Base Support Unit Boston · Activity 6180803
31 March 2017
Deficiency Check · Annual Inspection · MTSA Verification
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 6114894
24 February 2016
MTSA Verification · Annual Inspection
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 5823869
24 February 2016
Deficiency Check · Hull Examination
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 5825537
27 March 2014
Hull Examination · Deficiency Check · Administrative Inspection
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 4828420
11 March 2014
MTSA Verification · Annual Inspection
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 4813760
2 May 2012
Annual Inspection · Deficiency Check
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 4300382
27 September 2010
Administrative Inspection
Administrative · Sector Boston · USCG Northeast District (CGD-NE) · Activity 3858218
11 February 2010
COI Inspection · Drydock Exam
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 3676808
12 May 2009
Annual Inspection
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 3473141
15 May 2008
Deficiency Check · MTSA Verification · Annual Inspection
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 3207251
12 March 2008
Deficiency Check · Hull Examination · Examination of Repairs
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 3163095
22 May 2007
Re-Inspection
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 2936959
9 June 2006
Re-Inspection · Deficiency Check
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 2674701
24 February 2006
Hull Examination
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 2591153
1 August 2005
Damage Survey
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 2447474
30 May 2005
Type not recorded
No type recorded · Sector New York · USCG Northeast District (CGD-NE) · Activity 2373134
17 March 2005
MTSA Verification · COI Inspection
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 2312374
2 June 2004
Re-Inspection
Physical examination · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 2085936
2 June 2004
Hull Examination
Physical examination · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 2085978
17 December 2003
Security Plan Review - ASP
Administrative · Marine Safety Center (MSC) · Activity 1971026
28 March 2003
Re-Inspection
Physical examination · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 1764235
8 August 2002
Type not recorded
No type recorded · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 1663363
3 June 2002
Hull Examination
Physical examination · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 1602404
3 June 2002
Re-Inspection · Deficiency Check
Physical examination · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 1632524
20 April 2001
Deficiency Check
Physical examination · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 1063011
12 April 2001
Administrative
Administrative · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 1062131
6 April 2001
Construction Oversight · Plan Review "T" Boat
Physical examination · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 1366652
3 April 2001
Re-Inspection
Physical examination · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 1456957
19 March 2001
Administrative
Administrative · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 1059797
24 May 2000
Deficiency Check
Physical examination · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 1445626
10 May 2000
Deficiency Check
Physical examination · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 1386789
4 May 2000
Hull Examination
Physical examination · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 1361459
19 March 2000
Drydock Extension
Administrative · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 1430837
17 March 2000
COI Inspection · Deficiency Check
Physical examination · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 1439005
8 October 1999
Deficiency Check
Physical examination · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 1386609
29 September 1999
Deficiency Check
Physical examination · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 1346439
1 June 1999
Re-Inspection
Physical examination · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 804760
15 October 1998
Excursion Permit
Administrative · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 802859
20 September 1998
Type not recorded
No type recorded · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 97032
26 June 1998
Deficiency Check
Physical examination · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 1127310
15 May 1998
Re-Inspection
Physical examination · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 1125058
20 April 1998
Hull Examination
Physical examination · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 1124184
26 March 1998
Type not recorded
No type recorded · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 787255
19 March 1997
COI Inspection · Deficiency Check
Physical examination · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 1092215
6 September 1996
Deficiency Check
Physical examination · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 1256878
28 August 1996
Type not recorded
No type recorded · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 1088920
26 March 1996
Deficiency Check
Physical examination · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 1078685
5 March 1996
Hull Examination
Physical examination · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 886226
1 March 1996
COI Inspection
Physical examination · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 1077451
17 August 1995
Type not recorded
No type recorded · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 143406
13 July 1995
Type not recorded
No type recorded · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 8819
3 May 1995
Deficiency Check
Physical examination · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 1352345
19 April 1995
COI Inspection
Physical examination · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 861455
5 April 1995
Deficiency Check
Physical examination · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 840847
27 March 1995
Deficiency Check
Physical examination · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 829666
12 October 1994
Deadweight Survey
Physical examination · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 867667
19 July 1994
Administrative
Administrative · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 872718
18 May 1994
Hull Examination
Physical examination · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 859670
18 May 1994
COI Inspection
Physical examination · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 860743
27 August 1993
Administrative
Administrative · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 960446
3 May 1993
Deficiency Check · COI Inspection
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1156024
5 May 1992
COI Inspection
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 952962
24 April 1992
Hull Examination
Physical examination · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 1266394
11 October 1991
Drydock Extension
Administrative · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1251555
16 September 1991
Administrative
Administrative · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1310103
13 August 1991
Administrative
Administrative · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 934456
7 May 1991
Deficiency Check · COI Inspection
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1215645
16 November 1990
Deficiency Check
Physical examination · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 911708
9 May 1990
COI Inspection · Deficiency Check
Physical examination · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 1238642
25 April 1990
Hull Examination
Physical examination · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 929978
13 October 1988
COI Inspection
Physical examination · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 1200399
7 April 1988
Hull Examination
Physical examination · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 993428
26 October 1987
COI Inspection
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1012811
15 April 1987
Hull Examination
Physical examination · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 1329867
3 November 1986
COI Inspection
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1311346
6 February 1986
Credit Drydock · Examination of Repairs
Physical examination · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 1302054
13 November 1985
COI Inspection
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1301529
19 November 1984
Type not recorded
No type recorded · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1284827
Deficiency record · 327
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 17 April 2025
Resolved
The two required fixed power bilge pumps shall be self-priming and shall each be driven by different sources of power. Vessel has combined bilge/fire pump, cross connection for suction was not operation during the time of inspection. Repair or replace as necessary to the satisfaction of the attending marine inspector prior to carrying passengers.
46 CFR 182.25-10(c)
(Old T)
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 17 April 2025
Resolved
The minimum capacity of the power fire pump shall be 50 gallons per minute at a pressure of not less than 60 pounds per square inch at the pump outlet. The pump outlet shall be fitted with a pressure gauge. Port side pump gauge not working during inspection. Repair/replace to the satisfaction of the attending marine inspector.
46 CFR 181.10-1(c)
(Old T)
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 17 April 2025
Resolved
The individual bilge suction lines shall be led to a central control point or manifold. Each line shall be provided with a stop valve at the control point or manifold and in addition shall be provided with a check valve at some accessible point in the bilge line. Starboard engine room bilge suction line does not have a check valve installed to prevent back flooding. Install to the satisfaction of the attending marine inspector.
46 CFR 182.25-5(c)
(Old T)
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 17 April 2025
Resolved
Fuel lines shall be accessible, protected from mechanical injury, and effectively secured against excessive movement and vibration by the use of soft non-ferrous metal straps with no sharp edges. Port fuel tank return line was leaking during inspection. Repair to the satisfaction of the attending marine inspector.
46 CFR 182.20-40(b)(2)
(Old T)
07 - Fire Safety › N/A - No Subsystem › Fire prevention structural integrity
Issued 17 April 2025
Resolved
Decks between various spaces must meet the requirements of Table 116.415(c). The deck separating the port side engine room and the main deck accommodation space is required to be an A-60 boundary. Insulation was not properly secured in the port side engine room on the left side of the overhead and along the left side bulkhead. Secure with the proper grating to ensure A-60 boundary is met as per manufacturers recommendations for fire rating insulation, to the satisfaction of the attending marine inspector.
18 - Maritime Labour Convention (Not Applicable to PSC Exams conducted in the U.S.) › N/A - No Subsystem › Other (Minimum requirements)
Issued 17 April 2025
Resolved
Marine employers must establish programs for the chemical testing for dangerous drugs on a random basis of crewmembers on inspected vessels who: (1) Occupy a position, or perform the duties and functions of a position, required by the vessel's Certificate of Inspection; (2) Perform the duties and functions of patrolmen or watchmen required by this chapter; or, (3) Are specifically assigned the duties of warning, mustering, assembling, assisting, or controlling the movement of passengers during emergencies. Provide proof of company policy established for crewmembers that meet this requirement for chemical testing to the satisfaction of the attending marine inspector.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 17 April 2025
Resolved
All electrical installations shall be to the satisfaction of the Officer in Charge, Marine Inspection. Port generator light was out on main generator panel during inspection.
46 CFR 183.01-15
(Old T)
11 - Life Saving Appliances › N/A - No Subsystem › Operational readiness of lifesaving appliances
Issued 6 May 2024
Resolved
Vessels whose routes are restricted to 20 miles from a harbor of safe refuge shall carry life floats or buoyant apparatus for not less than 50 percent of all persons on board. 01 life float needs to be serviced and repaired. When vessel is more than 01 mile from shore passenger count is reduced to 220.
09 - Working and Living Conditions › 092 - Working Conditions › Other (accident prevention)
Issued 6 May 2024
Resolved
At each subsequent inspection for certification, re-inspection, and at every other vessel inspection, the marine inspector shall require that all observed unsafe practices and hazardous conditions are corrected. Vessel’s port generator had excessive oil on the rear part of the engine in the vicinity of the turbocharger. O/O is to clean affected area and re-route crankcase breather to prevent future oil and fire hazards from occurring.
46CFR176.25-50 (Old T-L)
02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 6 May 2024
Resolved
At each subsequent inspection for certification the marine inspector shall view the vessel afloat and conduct tests and inspections of the hull and its’ appurtenances. Upon visual examination of the hull and watertight envelope, damage was noted on the main deck port quarter of the vessel where the transom meets the side shell and deck. An approximate one-foot crack/tear was noted that penetrates the deck into the steering compartment. O/O is to submit a repair proposal documenting temporary and permanent repairs to the area for OCMI review.
46CFR176.25-5 (Old T-L)
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 6 May 2024
Resolved
Portable fire extinguishers shall be installed and located to the satisfaction of the [name withheld] extinguisher and mounting bracket in the vicinity of the bar area on the second deck was loose and never mounted to its’ designated location. O/O to mount extinguisher and its’ associated bracket in accordance with the vessel fire control plan.
46CFR181.30-10(b) (Old T-L)
11 - Life Saving Appliances › N/A - No Subsystem › Maintenance of Life Saving Appliances
Issued 26 April 2023
Resolved
Each ring life buoy must be marked with Type II retroreflective material approved in 46CFR164.018 in subchapter Q of this chapter or other standard specified by the Commandant. The arrangement of the retroreflective material applied after March 11, 1996, must be as specified by IMO Resolution A.658(16). Stern and Stbd 2nd deck lifering buoys missing pieces of correct retro-reflective tape.
11 - Life Saving Appliances › N/A - No Subsystem › Maintenance of Life Saving Appliances
Issued 26 April 2023
Resolved
Each floating waterlight must be attached to a lanyard with a corrosion-resistant clip. The clip must allow the waterlight to be quickly disconnected from the ring life buoy. Waterlight was found to be attached with a shackle.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Manholes/flush scuttles
Issued 26 April 2023
Resolved
A hatch exposed to the weather must be watertight. Port aft lazarette hatch was found with a 1 inch missing piece of gasket.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 6 May 2021
Resolved
All wiring and cable shall be suitable for marine
service and for particular installations used. In
addition, flexible or portable cords such as SO, STO,
and similar types cannot be used for permanently
installed wiring. Pilot house has multiple navigation
electronics plugged into surge protector portable cord.
Remove surge protector and install a permanent power
supply for vital navigation equipment. 46CFR183.10-20(a)(2)
10 - Safety of Navigation › N/A - No Subsystem › Lights, shapes, sound-signals
Issued 6 May 2021
Resolved
Vessels must have navigation lights that are in compliance with the applicable sections of the International and Inland Navigation Rules, except that a vessel of more than 19.8 meters (65 feet) in length must also have navigation lights that meet UL 1104, “Marine Navigation Lights,” or other standard specified by the Commandant. Port and Stbd side lights do not meet this requirement.
15 - Safety Management Systems (ISM) › N/A - No Subsystem › Emergency preparedness
Issued 6 May 2021
Resolved
All escape hatches and other emergency exits used as
means of escape must be marked on both sides in clearly
legible letters at least 50 millimeters (2 inches) high:
“EMERGENCY EXIT, KEEP CLEAR”, unless such markings are deemed unnecessary by the cognizant [name withheld] all escape exits according to regulation.
11 - Life Saving Appliances › N/A - No Subsystem › Operation of Life Saving Appliances
Issued 6 May 2021
Resolved
A vessel of more than 19.8 meters (65 feet) in length must carry a minimum of three life buoys of not less than 610 millimeters (24 inches) in diameter and must be IAW 160.050 in subchapter Q. Port aft ring buoy on main deck found with a hole in it exposing internal material. Repair or replace life ring.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 6 February 2020
Resolved
All vessels of 26 feet in length and over shall be provided with individual bilge lines and bilge suctions for each watertight compartment. The bilge suction in the portside water tank room (space #4) was not able to pump out water.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 6 February 2020
Resolved
The bilge suction shall be fitted with suitable strainers having an open area not less than three times the area of the bilge pipe. No strainer was found on the bilge pipe in the portside forepeak space.
02 - Structural Conditions › N/A - No Subsystem › Bulkhead -corrosion
Issued 6 February 2020
Resolved
At each initial/subsequent inspections for certification of a vessel, inspection of all accessible parts of the exterior & interior of the hull. There is extensive pitting in the WTD bulkhead in the #1 starboard void on the aft bulkhead just inboard of the fresh water intake bulkhead fitting. Replace prior to hull exam credit.
02 - Structural Conditions › N/A - No Subsystem › Bulkhead -corrosion
Issued 6 February 2020
Resolved
At each initial/subsequent inspections for certification of a vessel, inspection of all accessible parts of the exterior & interior of the hull. The fresh water intake bulkhead penetration in aft starboard void #1 is severely corroded. Replace prior to hull exam credit.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 6 February 2020
Resolved
Auxiliary machinery shall be suitable for the purpose intended and maintained in such a manner as to afford adequate protection again machinery failure and personnel injury. The port main engine in the starboard engine room exhaust discharge flexible pipe was missing a double clamp on the hull side.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 6 February 2020
Resolved
Mechanically propelled "L" vessels shall comply with the provisions of Subchapter F of this chapter. Nonmetallic flexible hose may be may be used in vital fresh and salt water systems at a maximum service pressure of 150 psi. Nonmetallic flexible hose may be used in lengths not exceeding 30 inches where flexibility is required. 04 sections of straight bilge pipe have been replaced with nonmetallic flexible hose where flexibility is not required. Replace prior to hull exam credit.
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 13 May 2019
Resolved
One length of fire hose shall be provided for each hydrant. 03 hoses unserviceable. Required prior to carrying passengers. 46 CFR 181.15-10
10 - Safety of Navigation › N/A - No Subsystem › Automatic Identification System (AIS)
Issued 12 September 2018
Resolved
Vsl is broadcasting invalid MMSI, Vsl is broadcasting NAME with Vsl type precursor (NAME must not include Vsl type precursors, e.g. F/V, M/V), Vsl is broadcasting no dimension information (AIS Antenna Position ABCD values equals 0) and Vsl is broadcasting no static draft information
03 - Water/Weathertight Conditions › N/A - No Subsystem › Machinery space openings
Issued 25 April 2018
Resolved
Replace stuffing box flange on portside inboard shaft.
02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 25 April 2018
Resolved
Repair crack in frame in void #3 & cracks on frames in void #2 as marked.
Engineering › Fuel Oil Storage/Transfer System › Tank
Issued 12 March 2018
Resolved
Repair leak in port side fuel tank to the satisfaction of the attending marine inspector.
Fire Fighting › Fire Hydrants › Condition
Issued 12 March 2018
Resolved
Repair port side aft fire station fitting.
Fire Fighting › Structural - A Class Divisions › Machinery Spaces
Issued 12 March 2018
Resolved
Provide structural fire protection in port side engine room in the two discussed location.
Engineering › Shafting/Propeller Arrangements › Flange/Thrust Collar Fillet
Issued 12 March 2018
Resolved
Repair or replace inboard portside flange on stuffing box.
Electrical › Electrical Distribution System (service) › Cable
Issued 12 March 2018
Resolved
Secure dead end wires in box.
Electrical › Lighting (emergency) › Battery Operated Lantern
Issued 12 March 2018
Resolved
Provide flashlight for each engine room.
Fire Fighting › Fire Hydrants › Material
Issued 12 March 2018
Resolved
Provide spanner wrench for fwd fire station.
Lifesaving › Lifefloat › Paddle
Issued 12 March 2018
Resolved
Stencil life float paddles with vessel name.
Fire Fighting › Fire Hydrants › Condition
Issued 31 March 2017
Resolved
STBD aft fire station leaking. Repair leaks.
Fire Fighting › Fire Main › Condition
Issued 31 March 2017
Resolved
Port fire main on main deck leaking. Repair leaks.
Fire Fighting › Fire Hydrants › Condition
Issued 31 March 2017
Resolved
Port aft fire station leaking. Repair leaks.
Electrical › Electrical Distribution System (service) › Switchboard
Issued 31 March 2017
Resolved
Cover opening on PORT switchboard.
Documentation › Markings/Placards › Warning Signs
Issued 31 March 2017
Resolved
Label 04 emergency escape hatches- "Emergency Exit, Keep Clear".
Electrical › Electrical Distribution System (service) › Junction Box
Issued 31 March 2017
Resolved
Mount junction box in galley.
Engineering › Bilge Water Management System › Piping
Issued 31 March 2017
Resolved
Repair deck drain pipe in PORT Lazarette.
Engineering › Steering Gear System › Hydraulic Hose
Issued 31 March 2017
Resolved
Repair hydraulic leak forward of operating station.
Construction/Loadline › Structures › Door
Issued 31 March 2017
Resolved
Make 02 pilothouse doors weather tight. 46 CFR 116.1160
Fire Fighting › Miscellaneous Items › A Class Division Penetrations
Issued 31 March 2017
Resolved
Port engine room bulkhead and overhead fire protection insulation were found to be damaged. Issued requirement to repair or replace insulation outboard and above the port reduction gear.
Stability › Watertight Integrity › General
Issued 24 February 2016
Resolved
Replace gasket in void #2, STBD side.
Stability › Watertight Integrity › General
Issued 24 February 2016
Resolved
Fill hole port side deck aft of 2nd frame above tunnel.
Engineering › Fuel Oil Storage/Transfer System › Piping
Issued 24 February 2016
Resolved
Replace wasted fuel return line in Port Machine Shop.
Fire Fighting › Fire Main › Condition
Issued 24 February 2016
Resolved
Repair leaking union on fire main above Z/C breaker in Port Machine Shop.
Fire Fighting › Nozzles › Type
Issued 24 February 2016
Resolved
Provide corrosion resitant fire nozzle of suitable material.
Documentation › Safety Management System › Designated Person(s) Documentation
Issued 24 February 2016
Resolved
Provide Senior deckhand designation letter.
Fire Fighting › Structural - A Class Divisions › Fire Doors
Issued 24 February 2016
Resolved
Repair "A" class fire door on 2nd deck accomodation space.
Lifesaving › Lifejacket/PFD (General) › Storage
Issued 24 February 2016
Resolved
Separate child and adult life jackets in fantail storage.
Lifesaving › Buoyant Apparatus › Serviceable
Issued 27 March 2014
Resolved
All of the vessel's buoyant apparatus are in unserviceable condition and have been removed for repair or replacement. Until they have been replaced on board, the vessel is limited to a Lakes, Bays and Sounds route inside a line drawn from Eastern Point, MA to the Graves then to Strawberry Point, MA and not more than one mile from shore under reasonable operating conditions.
Engineering › Engine Controls (Electric/Electronic) › Linkage
Issued 2 May 2012
Resolved
Temperature gauge in pilot house inoperable for port outboard engine.
Navigation › Piloting/Steering › Magnetic Compass
Issued 2 May 2012
Resolved
Repair inoperable magnetic compass light.
Lifesaving › Lifebuoys › Self-igniting Lights
Issued 2 May 2012
Resolved
Waterlight full of water. Replace waterlight for life float secured in stbd side, bottom, inboard.
Electrical › Electrical Distribution System (service) › Wiring
Issued 2 May 2012
Resolved
Properly support engine wiring in accordance with 46 CFR 111.60-17
Electrical › Electric Supply System (service) › Transformer
Issued 2 May 2012
Resolved
Transformer protection for shore power must be in accordance with 46 CFR 111.20-1. Secure and label for pax safety.
Engineering › Generator (propulsion/auxiliary-electric) › Winding
Issued 11 February 2010
Resolved
Repair/re-build inop starboard generator
Electrical › Electric Supply System (service) › Battery Installation
Issued 11 February 2010
Resolved
Replace all cracked 32 volt batteries in pilot house console.
Electrical › Lighting (service) › Lighting Fixture
Issued 11 February 2010
Resolved
Place exposed wires under pilot house in proper junction box.
Lifesaving › Hand Flares › Expired
Issued 11 February 2010
Resolved
Replace out of date sigmnal flares.
Engineering › Fuel Oil Service System › Hose
Issued 11 February 2010
Resolved
Replace fuel hoses in port and starboard fuel filter system that do not have properly fitted connections.
Accommodation/Occupational Safety › Occupational Safety › Guards for Exposed Hazards
Issued 11 February 2010
Resolved
Replace missing machinery guards for all MDE's
Fire Fighting › Fixed Fire Detection System › Annual Inspection
Issued 11 February 2010
Resolved
Provide fire service report.
Lifesaving › Buoyant Apparatus › Serviceable
Issued 11 February 2010
Resolved
Install all Bouyant apparatus properly prior to carrying passengers.
Engineering › Fuel Oil Service System › Hose
Issued 15 May 2008
Resolved
Replace f/o hose on stbd outboard MDE.
Engineering › Diesel Engine (propulsion-direct drive) › Piping (exhaust)
Issued 15 May 2008
Resolved
Make repairs to cracked vent line & replace rubber boot on port, outboard MDE
Fire Fighting › Fire Main › Material
Issued 15 May 2008
Resolved
Replace rubber hose connection on discharge side of firepump w/ metallic piping.
Engineering › Diesel Engine (propulsion-direct drive) › Piping (exhaust)
Issued 15 May 2008
Resolved
Install lagging of exhaust pipe of starboard, inboard MDE
Lifesaving › Visual Distress Signals (General) › Expired
Issued 15 June 2006
Resolved
Provide six orange smoke distress signals.
Lifesaving › Lifebuoys › Markings (ship name/port)
Issued 15 June 2006
Resolved
Stencil the vessels name on the new life ring.
Lifesaving › Lifefloat › Serviceable
Issued 15 May 2006
Resolved
Repair all of the cracks as needed with an approved repair kit on all of the lifefloats.
Fire Fighting › Fixed CO2 Fire Extinguishing System › Servicing
Issued 15 May 2006
Resolved
Inspect the fixed CO2 fire extinguishing system for the engine room.
Construction/Loadline › Structures › Scuttle
Issued 15 May 2006
Resolved
Provide and install retaining devices for the lazzarette hatches.
Engineering › Bilge Water Management System › Piping
Issued 24 February 2006
Resolved
Due to piping and pump replacement system will need to be operationally tested prior to vessel operation
Engineering › Fuel Oil Service System › Piping
Issued 17 March 2005
Resolved
Repair fuel supply piping on Port outboard MDE. Pipe needs to be in bracket.
Fire Fighting › Portable Dry Chemical Fire Extinguisher › Mounting Bracket
Issued 17 March 2005
Resolved
Repair all fire extinguisher brackets.
Construction/Loadline › Penetrations › Gasket
Issued 17 March 2005
Resolved
Renew hatch gaskets on port and starboard voids.
Deck/Cargo › Holds/Tanks › Hatch
Issued 17 March 2005
Resolved
Repair hatch lanyards on stbd void.
Electrical › Electrical Distribution System (service) › Cable
Issued 17 March 2005
Resolved
Provide chaffing protection on transformer cable that runs under port generator.
Engineering › Bilge Water Management System › Valve
Issued 17 March 2005
Resolved
Renew port forepeak valve.
Construction/Loadline › Hull › Transverse Frame
Issued 17 March 2005
Resolved
Shelf connecting port and starboard hull voids is holding water and starting to rot the aluminum, properly repair or remove this water.
Accommodation/Occupational Safety › Occupational Safety › Guards for Exposed Hazards
Issued 17 March 2005
Resolved
Renew lagging on all engine exhaust.
Engineering › Diesel Engine (propulsion-reduction gear) › Crankcase
Issued 17 March 2005
Resolved
Renew oil crankcase breather hose on port outboard MDE.
Engineering › Bilge Water Management System › Piping
Issued 17 March 2005
Resolved
Renew inboard bilge dewatering pipe running through port storeroom void. (pipe is wasted)
Stability › Unintentional Flooding › General
Issued 2 June 2004
Resolved
Remove water from #1 void in both hulls prior to carrying passengers.
Construction/Loadline › Penetrations › Weld
Issued 2 June 2004
Resolved
Properly repair doubler plate on sewage tank bulkhead. (Void #2 Stbd tank)
Construction/Loadline › Hull › Bottom Plating
Issued 2 June 2004
Resolved
Prior to carrying passengers Remove vessel from water and conduct further inspection on HUll.
Construction/Loadline › Penetrations › Valve Flange
Issued 8 April 2004
Resolved
Void #1 stbd hull properly repair through hull valve. (valve will not open or close)
Construction/Loadline › Penetrations › Valve Flange
Issued 8 April 2004
Resolved
Properly repair through hull valve in #2 void port side hull (valve will not open or close)
Construction/Loadline › Penetrations › Valve Flange
Issued 8 April 2004
Resolved
Properly repair through hull valve in #2void stbd hull (valve will not open or close)
Engineering › Fuel Oil Service System › Piping
Issued 8 April 2004
Resolved
Properly repair loose fuel piping (pipe is not properly secured)
Stability › Unintentional Flooding › General
Issued 8 April 2004
Resolved
Remove port side waste oil from fuel tank void. (waste oil was being stored in port side old fuel tank, supposed to be void) explained to owner that this cannot be used as waste oil storage.
Operations/Management › Pollution › Control of Discharge of Sewage
Issued 8 April 2004
Resolved
Properly repair deck drain (currently piped to sewage system vice ovbd)
Electrical › Electric Supply System (service) › Battery Installation
Issued 8 April 2004
Resolved
Properly secure battery boxes in port engine room.
Stability › Unintentional Flooding › General
Issued 8 April 2004
Resolved
Provide plug for old fuel piping currently used as void, if this void were to flood and old piping is not blanked off it could possibly flood engine room.
Electrical › Electric Supply System (service) › Battery Conductor
Issued 8 April 2004
Resolved
Properly run battery cables in stbd engine room.
Electrical › Electrical Distribution System (service) › Switch
Issued 8 April 2004
Resolved
Properly repair knife switch used as a disconnect for anchor windlass.
Accommodation/Occupational Safety › Other Accommodation Spaces › Open Deck Space
Issued 8 April 2004
Resolved
Properly repair all fire screen doors so that they self close and latch.
Fire Fighting › Fixed CO2 Fire Extinguishing System
Issued 28 March 2003
Resolved
Provide servicing certificate for both CO2 fixed fire extinguishing systems.
Fire Fighting › Fire Hoses
Issued 28 March 2003
Resolved
Provide a fire hose listed by either Underwriters Laboratories (UL) of Factory Mutual (FM), and perform a satisfactory hydrostatic test of the hose in the presence of the attending marine inspector. LEGACY COMPONENT DESC: Condition
Navigation › Piloting/Steering
Issued 28 March 2003
Resolved
Provide a recently calculated magnetic compass deviation table. LEGACY COMPONENT DESC: Deviation Table/Graph
Communications › Radio Communications
Issued 28 March 2003
Resolved
Prove proper operation of second Furuno VHF-FM radio. LEGACY COMPONENT DESC: VFH Radiotelephone
Electrical › Electric Supply System (service)
Issued 28 March 2003
Resolved
Block and brace generator batteries and bridge equipment batteries. LEGACY COMPONENT DESC: Battery Installation
Communications › Alarms/Indicators › Bilge Alarm
Issued 3 June 2002
Resolved
Prior to carrying passengers, properly repair bilge high level system.
Fire Fighting › Fixed CO2 Fire Extinguishing System
Issued 3 June 2002
Resolved
Prior to carrying passengers, properly service both Port and Stbd fixed firefighting systems.
Fire Fighting › Fire Pumps › Pressure
Issued 3 June 2002
Resolved
Prior to carrying passengers prove proper operation of both fire pumps. Proper operation is 60psi at 50 gallons per minute.
Engineering › Diesel Engine (propulsion-reduction gear)
Issued 3 June 2002
Resolved
Prior to carrying passengers, properly repair port hull outboard MDE-excessive oil leaking from filter housing.
Engineering › Fuel Oil Service System
Issued 3 June 2002
Resolved
Prior to carrying passengers, remove unathorized fuel level hose from port hull fuel tank. LEGACY COMPONENT DESC: Gauge
Operations/Management › Drills/Instruction › Man Overboard Recovery
Issued 3 June 2002
Resolved
Prior to carrying passengers, prove proper Man overboard drill.
Engineering
Issued 3 June 2002
Resolved
Prior to carrying passengers, properly repair fwd stbd hull bilge valve.
Engineering › Diesel Engine (propulsion-reduction gear)
Issued 3 June 2002
Resolved
Properly repair remote shutdown switch prior on port outboard MDE.
Engineering › Diesel Engine (propulsion-reduction gear)
Issued 3 June 2002
Resolved
Replace oil psi gauge line on port inboard MDE.
Engineering › Diesel Engine (propulsion-reduction gear)
Issued 3 June 2002
Resolved
Replace port outboard MDE fuel line between valve and filter.
Electrical › Electrical Distribution System (service) › Switch
Issued 3 June 2002
Resolved
Properly wire bypassed A.C. knife switch.
Navigation
Issued 3 June 2002
Resolved
Provide updated light list.
Communications › Audible Communications › Bell
Issued 3 June 2002
Resolved
Mount Bell in accessible area.
Communications › Alarms/Indicators › Lube Oil Low Pressure Alarm
Issued 3 June 2002
Resolved
Properly label red lights on console.
Communications › Radio Communications › EPIRB
Issued 3 June 2002
Resolved
Prior to carrying passengers replace hydrostatic release on EPIRB.
Accommodation/Occupational Safety › Occupational Safety
Issued 3 June 2002
Resolved
Replace port bridge window.
Stability › Watertight Integrity
Issued 3 June 2002
Resolved
Replace Stbd FWD lanyard on weatherdeck hatch.
Accommodation/Occupational Safety › Occupational Safety
Issued 3 June 2002
Resolved
Repair all doors so that they are self closing and self latching. LEGACY COMPONENT DESC: Weatherdeck doors
Electrical › Lighting (service) › Lighting Feeder
Issued 3 June 2002
Resolved
Properly wire lights in pumproom.
Accommodation/Occupational Safety › Potable Water System
Issued 3 June 2002
Resolved
Properly mount hot water heater. LEGACY COMPONENT DESC: hot water heater
Accommodation/Occupational Safety › Occupational Safety
Issued 3 June 2002
Resolved
Properly secure Co2 cylinders in storeroom. LEGACY COMPONENT DESC: Pressurized CO2 cylinders for soda fountain
Engineering › Bilge Water Management System
Issued 3 June 2002
Resolved
Prior to carrying passengers prove proper operation of Port Bilge system.
Lifesaving › Buoyant Apparatus
Issued 3 June 2002
Resolved
Prior to carrying passengers, repack 16 lifefloats to be able to float free. LEGACY COMPONENT DESC: Lifefloats
Communications › Alarms/Indicators
Issued 3 June 2002
Resolved
Properly repair oil pressure alarm system NLT 21JUN02. LEGACY COMPONENT DESC: Lube Oil Low Pressure Alarm
Fire Fighting › Fixed CO2 Fire Extinguishing System
Issued 3 June 2002
Resolved
Properly repair fixed fire fighting extinguishing system to show that system is charged. LEGACY COMPONENT DESC: Quantity of CO2
Accommodation/Occupational Safety › Other Accommodation Spaces
Issued 21 May 2002
Resolved
Properly repair all rail courses prior to 05 JUN 02.
Construction/Loadline › Structures
Issued 26 March 2002
Resolved
Properly repair cracked weld in forepeak stiffiner NLT 03APR02.
Construction/Loadline › Structures
Issued 26 March 2002
Resolved
Properly repair Approx 2" hole in Men's head deck. LEGACY COMPONENT DESC: Deck Plating
Construction/Loadline › Hull
Issued 26 March 2002
Resolved
Properly repair A. C. drain line hole in Port engine room bulkhead.
Construction/Loadline
Issued 26 March 2002
Resolved
Remove or reattach corrugated sheet metal in way of port steering ram.
Construction/Loadline › Structures
Issued 26 March 2002
Resolved
Make aft Integral fuel tanks available for inspection NLT05APRIL02.
Accommodation/Occupational Safety › Other Accommodation Spaces
Issued 26 March 2002
Resolved
Repair all rail courses prior to carrying passengers.
Communications › Alarms/Indicators
Issued 26 March 2002
Resolved
Remove sewage from port void and prove float works on hegh level alarm. LEGACY COMPONENT DESC: Bilge Alarm
Accommodation/Occupational Safety › Occupational Safety
Issued 26 March 2002
Resolved
Replace all captive chains on deck hatches that need them.
Engineering
Issued 26 March 2002
Resolved
Remove and wipe out fuel in FWD engine room bilges prior to carrying passengers.
Electrical
Issued 26 March 2002
Resolved
Properly repair Transformer on fantail prior to carrying passengers.
Accommodation/Occupational Safety
Issued 6 April 2001
Resolved
Prior to final approval for operation of the oil-fired furnace, complete 8 item worklist as indicated in MINS for this case.
Electrical
Issued 3 April 2001
Resolved
PROVIDE GLOBES AND GUARDS FOR ENGINE ROOM LIGHTS.
Fire Fighting
Issued 3 April 2001
Resolved
REPAIR ALL FIRE DOOR LATCHES AND INSTALL MISSING FIRE DOORS.
Fire Fighting
Issued 3 April 2001
Resolved
PROVIDE PRESSURE GAUGES AND PROVE PROPER OPERATION TO BOTH FIRE PUMPS.
Lifesaving
Issued 3 April 2001
Resolved
LABEL ENGINE ROOM EMERGENCY EXITS IN ENGINEROOM.
Engineering
Issued 3 April 2001
Resolved
PROVIDE ROTATING MACHINERY GUARDS FOR BOTH GENERATORS.
Engineering
Issued 3 April 2001
Resolved
PRIOR TO CARRYING PASSENGERS REPAIR LUBE OIL LEAK TO PORT ENGINE ROOM OUTBOARD MDE TURBOCHARGER.
Lifesaving
Issued 3 April 2001
Resolved
PRIOR TO CARRYING PASSENGERS INSTALL EPIRB.
Accommodation/Occupational Safety
Issued 3 April 2001
Resolved
PROPERLY SECURE SEWAGE OVERBOARD VALVES.
Engineering
Issued 3 April 2001
Resolved
PROVIDE FLYWHEEL GUARD ON OUTBOARD MDE IN STBD ENG RM.
Construction/Loadline
Issued 4 May 2000
Resolved
Starboard engine room bilge suction soft patched. Make proper permanent repair to the bilge suction piping.
Construction/Loadline
Issued 4 May 2000
Resolved
Side shell wasted and holed in board on the starboard hull inway of sewage tank. Empty tank gas free space crop to sound metal and make properly insert side shell.
Construction/Loadline
Issued 4 May 2000
Resolved
Ballast tank fill line passing through the sewage holding tank wasted and holed. Crop and renew ballast fill line to restore as original._x001C_
Construction/Loadline
Issued 4 May 2000
Resolved
Engine room bilge suction line located in the port machinery space os soft patched, wasted and holed. Make permanent repair to bilge line as original.
Navigation
Issued 4 May 2000
Resolved
Diagonal support for the port rudder tube fractured. Make permanent repairto the port rudder tube diagonal support.
Electrical
Issued 4 May 2000
Resolved
Electrical cables not properly supported improper plate penetration cable chaffing. Properly support electric cables located in the port #2 void.
Navigation
Issued 4 May 2000
Resolved
Port rudder slamming against shaft tube. Shaft tube visibly gouged. Provide proper rudder stops for the port rudder.
Construction/Loadline
Issued 17 March 2000
Resolved
RELABEL BILGE MANIFOLD.
Fire Fighting
Issued 17 March 2000
Resolved
RELABEL VALVES TO COINCIDE WITH POSTED INSTRUCTIONS FOR PROPER OPERATION OFBOTH PORT AND STARBOARD FIRE PUMPS.
Lifesaving
Issued 17 March 2000
Resolved
MAKE VESSEL AVAILABLE WITH CREW TO CONDUCT SATISFACTORY UNDERWAY DRILLS TO THE SATISFACTION OF AN ATTENDING USCG MARINE INSPECTOR.
Fire Fighting
Issued 17 March 2000
Resolved
VESSEL IS NOT TO BE OPERATED WITH PASSENGERS UNTIL PROOF IS PROVIDED THAT THE PORT E/R FIXED EXTINGUISHING SYSTEM IS PROPERLY CHARGED AND TESTED.
Lifesaving
Issued 17 March 2000
Resolved
PROVIDE THREE RING BUOYS.
Lifesaving
Issued 17 March 2000
Resolved
PROVIDE ONE WATERLIGHT.
Construction/Loadline
Issued 17 March 2000
Resolved
PROVIDE HANDLES FOR PORT AND STARBOARD EMERGENCY ESCAPE HATCHES IN PUMP ROOMS AND ENGINE ROOMS.
Electrical
Issued 17 March 2000
Resolved
REMOVE DEAD ENDED WIRE IN PORT PUMP ROOM.
Electrical
Issued 17 March 2000
Resolved
REPLACE MISSING GLOBES AND GUARDS ON LIGHT FIXTURES THROUGHOUT THE VESSEL.
Electrical
Issued 17 March 2000
Resolved
REPLACE THREE MISSING EMERGENCY LIGHT BULBS.
Navigation
Issued 1 June 1999
Resolved
MAKE PERMANENT REPAIR TO CRACKED RUDDER TUBE SUPPORT BRACING IN THE STARBOARD STEERING COMPARTMENT.
Fire Fighting
Issued 1 June 1999
Resolved
MAKE PERMANENT REPAIR TO THE HOLED MAIN DECK FIRE HYDRANT PORT SIDE FORWARD.
Construction/Loadline
Issued 1 June 1999
Resolved
MODIFICATIONS OF PIPE PENETRATIONS THROUGH WATERTIGHT BULKHEADS INCLUDE IMPROPER PVC PIPE INSTALLATION. RESTORE PIPE PENETRATIONS AS ORIGINAL OR BRING INTO COMPLIANCE WITH 46CFR 119.720 AND 46CFR 56.50.
Construction/Loadline
Issued 1 June 1999
Resolved
RUBBER HOSE IN USE IN THE BILGE SYSTEM. REMOVE ALL RUBBER HOSE AND REPLACEAS ORIGINAL IN ACCORDANCE WITH 46 CFR 119.510 AND 46 CFR 56.50-50.
Fire Fighting
Issued 1 June 1999
Resolved
PROVIDE A DETAILED REPORT OF THE SERVICING OF THE FIXED CO2 SYSTEMS SPECIFICALLY INDENTIFYING THE TESTS CONDUCTED AND ITEMS EXAMINED.
Fire Fighting
Issued 1 June 1999
Resolved
PROVIDE COMPLETE BUT SIMPLE INSTRUCTIONS FOR THE OPERATION OF THE FIXED GASFIRE EXTINGUISHING SYSTEMS. THE INSTRUCTIONS MUST BE LOCATED IN A CONSPICUOUS PLACE WHERE THE CYLINDERS ARE STORED.
Unknown
Issued 15 May 1998
Resolved
INSTALL SECURING DEVICE FOR UPRIGHT CO2 TANKS USED FOR BAR.
Fire Fighting
Issued 15 May 1998
Resolved
DEVELOP AND POST EMERGENCY CHECK OFF LIST.
Accommodation/Occupational Safety
Issued 15 May 1998
Resolved
INSTALL SECURING DEVICE FOR SECURITY GATES THAT LOCK IN THE OPEN POSITION WHILE PASSSENGERS ARE ONBOARD
Lifesaving
Issued 15 May 1998
Resolved
OPERATOR TO PROVIDE VALID FCC OPERATOR PERMIT.
Lifesaving
Issued 15 May 1998
Resolved
REMOVE APPROXIMATELY 325 DEFECTIVE LIFEJACKETS WITH THE FOLLOWING DATA:_x001C_ GENTEX, GENTEX CORPORATION, CARBONDALE, PA. TYPE 1, MODEL #501U22_x001C_ AND REPLACE WITH COAST GUARD APPROVED DEVICES.
Lifesaving
Issued 20 April 1998
Resolved
INSTALL HIGH WATER LEVEL ALARMS IN COMPARTMENTS WITH NEWLY INTALLED THRU- HULL FITTINGS FOR MSD RAW WATER INTAKE.
Lifesaving
Issued 26 March 1998
Resolved
while conducting inspection for Credit Drydock Extension, noted numerous portable, fluid filled, electric heaters throughout the vessel. Issued CG-835 to remove or properly install heaters prior to carrying passengers for hire.
Construction/Loadline
Issued 26 March 1998
Resolved
On March 27, 1998, completed inspection allowing Credit Drydock extension. Issued CG-835 requiring the vessel be made available for Credit Drydock examination prior to April 30, 1998.
Accommodation/Occupational Safety
Issued 19 March 1997
Resolved
AT THE NEXT REGULARLY SCHEDULED DRYDOCK BUT NOT LATER THAN 31MAR98, GRIND OUT AND REWELD THE TWO FRACTURES IN THE MAIN DECK SAFETY RAILING, PORT AND STARBOARD QUARTERS, WHERE MARKED.
Accommodation/Occupational Safety
Issued 19 March 1997
Resolved
PRIOR TO NEXT HULL EXAM BUT NOT LATER THAN 31MAR98, GRIND OUT AND WELD THE TWO FRACTURES IN THE MAIN DECK HAND RAIL, STARBOARD QUARTER AND PORT QUARTER WHERE MARKED.
Lifesaving
Issued 19 March 1997
Resolved
REFASTEN THE OVERHEAD VENT IN THE MENS HEAD, MAIN DECK.
Lifesaving
Issued 19 March 1997
Resolved
PROPERLY STENCIL THE UPPER DECK LIFEJACKET STORAGE LOCKERS WITH THE NUMBER OF JACKETS CONTAINED IN EACH.
Electrical
Issued 19 March 1997
Resolved
PROPERLY DEAD END (CRIMP) THE LOOSE WIRES IN THE WHEEL HOUSE UNDER THE CONSOLE.
Accommodation/Occupational Safety
Issued 19 March 1997
Resolved
SUBMIT WRITTEN PROPOSAL FOR THE INSTALLATION OF NEW DECK DOORS ON THE #2 DECK.
Documentation
Issued 19 March 1997
Resolved
PLACE MARPOL ANNEX V PLACARDS ON THE VESSEL AS DISCUSSED.
Lifesaving
Issued 19 March 1997
Resolved
PRIOR TO CARRYING PASSENGERS, REMOVE THE WELDING MACHINE FROM THE STERN OF THE VESSEL.
Lifesaving
Issued 19 March 1997
Resolved
SHOW PROPER STOWAGE OF ALL LIFE FLOATS, WATERLIGHTS AND PADDLES.
Electrical
Issued 19 March 1997
Resolved
MAKE THE SHORETIE ELECTRICAL TRANSFORMER BOX ON THE STERN WATERTIGHT.
Electrical
Issued 19 March 1997
Resolved
MAKE THE ELECTRICAL JUNCTION BOX, STARBOARD QUARTER NEAR LADDER, WATERTIGHT.
Lifesaving
Issued 19 March 1997
Resolved
PROVIDE APPROPRIATE LATCHING DEVICES FOR THE PORT AND STARBOARD STORAGE LOCKERS ON THE STERN.
Lifesaving
Issued 19 March 1997
Resolved
REMOVE ALL SHARP AND JAGGED EDGES FROM THE METAL LATTICE WORK NEAR THE STARBOARD QUARTER LADDER LEADING TO THE SECOND DECK.
Construction/Loadline
Issued 19 March 1997
Resolved
GRIND OUT AND REWELD THE FRACTURED WELDS ON THE STARBOARD QUARTER RAIL STANCHION AND PORT QUARTER RAIL WHERE MARKED.
Lifesaving
Issued 19 March 1997
Resolved
LABEL STERN PAINT LOCKER AND STENCIL AS "NO SMOKING AREA".
Lifesaving
Issued 19 March 1997
Resolved
PRIOR TO CARRYING PASSENGERS, PERMANENTLY SECURE THE LARGE CONVECTION OVEN SITTING ON THE COUNTER IN THE GALLEY.
Lifesaving
Issued 19 March 1997
Resolved
REHANG THE LOUVERED HEATER VENTS, MAIN DECK, PORT AND STRABOARD SIDE, WHERELOOSE.
Lifesaving
Issued 19 March 1997
Resolved
PRIOR TO CARRYING PASSENGERS, REMOVE THE WELDING MACHINE OFF THE STERN OF THE VESSEL.
Lifesaving
Issued 19 March 1997
Resolved
SUBMIT PLANS SHOWING THE ADDITION OF LIFE FLOAT STORAGE AREA.
Lifesaving
Issued 19 March 1997
Resolved
PRIOR TO CARRYING PASSENGERS, PERMANENTLY SECURE THE CURRENTLY UNUSED CONVECTION OVEN LOCATED IN THE GALLEY.
Construction/Loadline
Issued 19 March 1997
Resolved
REPLACE MISSING BOLTS ON PORT QUARTER FUEL HATCH.
Lifesaving
Issued 19 March 1997
Resolved
PROVIDE A BRIGHTLY COLORED WATERTIGHT DISTRESS SIGNAL CONTAINER STENCILED WITH "DISTRESS SIGNALS" IN 1/2" LETTERS.
Electrical
Issued 19 March 1997
Resolved
MAKE BOTH ELECTRICAL JUNCTION BOXES ON TOP OF THE WHEEL HOUSE NEAR THE MASTWATERTIGHT.
Electrical
Issued 19 March 1997
Resolved
MAKE THE VERTICAL CABLE RUNS ON TOP OF THE WHEEL HOUSE WATERTIGHT.
Electrical
Issued 19 March 1997
Resolved
PROPERLY CRIMP THE ELECTRICAL SPLICE TO THE SPOTLIGHT.
Electrical
Issued 19 March 1997
Resolved
PROVE PROPER OPERATION OF ALL EMERGENCY LIGHTING.
Accommodation/Occupational Safety
Issued 19 March 1997
Resolved
REMOVE OR MAKE OPERATIONAL THE CONVECTION OVEN BEING STORED IN THE GALLEY.
Lifesaving
Issued 19 March 1997
Resolved
PROVIDE WRITTEN MAN OVERBOARD RECOVERY PROCEDURES.
Lifesaving
Issued 19 March 1997
Resolved
REMOVE THE WELDING MACHINE FROM THE STERN OF THE VESSEL.
Accommodation/Occupational Safety
Issued 19 March 1997
Resolved
PROVE PROPER OPERATION OF ALL HEADS, WASH BASINS AND ASSOCIATED PIPING.
Engineering
Issued 19 March 1997
Resolved
DOUBLE CLAMP ALL OVERBOARD DISCHARGE FITTINGS IN BOTH ENGINE ROOMS.
Documentation
Issued 19 March 1997
Resolved
PROVIDE COMPLETE DRUG TESTING PAPERWORK AS DISCUSSED.
Electrical
Issued 19 March 1997
Resolved
PROPERLY CRIMP CONNECT THE SPLICE AND PROVIDE CHAFFING RELIEF FOR THE STARBOARD ENGINE ROOM BATTERY LEADS.
Electrical
Issued 19 March 1997
Resolved
PROPERLY CRIMP CONNECT ALL ELECTRICAL CONNECTIONS TO THE STARBOARD CONSTAVOLT.
Electrical
Issued 19 March 1997
Resolved
PROPERLY DEAD END (CRIMP) THE CABLE HANGING FROM THE HEATING UNIT LOCATED INSIDE THE STARBOARD ENGINE ROOM DOOR.
Electrical
Issued 19 March 1997
Resolved
PROPERLY LABEL THE PORT ENGINE ROOM ELECTRICAL PANEL LOCATED FORWARD OF THEWATERTIGHT DOOR.
Lifesaving
Issued 28 August 1996
Resolved
Mark each ring buoy with type II retro-reflective tape approved_x001C_ in accordance with 46 CFR 164.018. Arrangement of the material must be as specified by IMO Resolution A658(16). _x001C_
Accommodation/Occupational Safety
Issued 26 March 1996
Resolved
PRIOR TO THE CARRIAGE OF PASSENGERS, PROVE PROPER OPERATION OF ALL HEAD FACILITIES, INCLUDING ALL ASSOCIATED PIPING, TO THE SATISFACTION OF AN ATTENDING COAST GUARD MARINE INSPECTOR.
Construction/Loadline
Issued 26 March 1996
Resolved
PRIOR TO PLACING VESSEL IN SERVICE OR THE CARRIAGE OF PASSENGERS, REPLACE THE THRU HULL FITTING, PORT PONTOON INBOARD, SERVING THE HEAD DECK DRAIN WHERE CURRENTLY PLUGGED WITH A WOOD CONICAL PLUG.
Accommodation/Occupational Safety
Issued 5 March 1996
Resolved
MAKE PERMANENT REPAIRS TO THE MSD DRAIN LINE WHERE HOLED, PORT SIDE, WHERE PASSING THROUGH THE #1 VOID AFT BULKHEAD.
Engineering
Issued 5 March 1996
Resolved
INSTALL GASKETS AND SECURING BOLTS ON BOTH PORT AND STARBOARD AFT FUEL TANKACCESS HATCHES.
Construction/Loadline
Issued 5 March 1996
Resolved
RENEW BROKEN BILGE SUCTION LINE, PORT SIDE MIDDLE LINE, IN THE STORAGE SPACE.
Accommodation/Occupational Safety
Issued 5 March 1996
Resolved
REHANG AC/HEAT LOUVERED VENTS, MAIN DECK PORT AND STARBOARD SIDE.
Electrical
Issued 1 March 1996
Resolved
REWIRE AND REPOSITION POWER SUPPLY CABLE TO STARBOARD PONTOON HIGH WATER ALARM.
Engineering
Issued 1 March 1996
Resolved
RENEW/INSTALL AIR INTAKE SCREENS ON ALL FOUR MDE'S.
Engineering
Issued 1 March 1996
Resolved
INSTALL LAGGING ON THE STARBOARD INBOARD MDE WHERE MISSING.
Engineering
Issued 1 March 1996
Resolved
CAP BOTH PORT AND STARBOARD LUBE OIL TANK DRAIN LINES.
Fire Fighting
Issued 1 March 1996
Resolved
THE FIXED CO2 EXTINGUISHING SYSTEM IS TO BE PROFESSIONALLY SERVICED IN THE PRESENCE OF AN ATTENDING COAST GUARD MARINE INSPECTOR NO LATER THAN 30APR96.
Accommodation/Occupational Safety
Issued 1 March 1996
Resolved
PRIOR TO THE CARRIAGE OF PASSENGERS, PROVE PROPER OPERATION OF ALL HEAD FACILITIES, INCLUDING ALL ASSOCIATED PIPING, TO THE SATISFACTION OF AN ATTENDING COAST GUARD MARINE INSPECTOR.
Electrical
Issued 1 March 1996
Resolved
LABEL ALL MAIN DISTRIBUTION PANEL ELECTRICAL BREAKERS.
Engineering
Issued 1 March 1996
Resolved
DOUBLE CLAMP ALL MDE COOLING WATER SUCTION LINES.
Fire Fighting
Issued 1 March 1996
Resolved
PLACE A SPANNER WRNECH AT THE PORT SIDE AFT MAIN DECK FIRE STATION.
Engineering
Issued 1 March 1996
Resolved
INSTALL 30X30 WIRE MESH FLAME SCREENS OVER BOTHE FUEL TANK VENTS.
Electrical
Issued 1 March 1996
Resolved
PLUG HOLES IN THE ELECTRICAL JUNCTION BOX, PORT SIDE MAIN DECK ON THE RIGHTOF THE GALLEY WINDOW.
Accommodation/Occupational Safety
Issued 1 March 1996
Resolved
STENCIL BOTH ENGINE ROOM EMERGENCY ESCAPE HATCHES ON THE MAIN DECK SIDE OF THE HATCH TO PREVENT STORAGE OF GEAR OVER THE HATCH.
Construction/Loadline
Issued 1 March 1996
Resolved
MARK THE HAILING PORT ON THE STERN OF THE VESSEL IN ACCORDANCE WITH 46CFR SUBCHAPTER G.
Navigation
Issued 1 March 1996
Resolved
PRIOR TO OPERATING, REMOUNT THE MASTHEAD LIGHT IN ACCORDANCE WITH THE NAVIGATIONAL RULES OF THE ROAD, ANNEX I, PARAGRAPHS 1 AND 2.
Lifesaving
Issued 1 March 1996
Resolved
RESTENCIL THE UPPER DECK LIFEJACKET STORAGE BINS AND LABEL THE MAIN DECK LIFEJACKETS STORAGE AREA FOR PASSENGER VIEWING.
Electrical
Issued 1 March 1996
Resolved
RECONNECT THE PORT A/C LOOSE WIRE NEAR THE CONTROL BOX UNDER THE PILOT HOUSE.
Electrical
Issued 1 March 1996
Resolved
REMOUNT THE UPPER DECK PORT SIDE ELECTRICAL OUTLET IN THE BAR.
Accommodation/Occupational Safety
Issued 19 April 1995
Resolved
MAKE PORT AND STBD ENGINE ROOM WEATHER DECK DOORS WEATHERTIGHT.
Electrical
Issued 19 April 1995
Resolved
PROVE PROPER OPERATION OF ENGINE ROOM AND GALLEY EMERGENCY LIGHTING.
Unknown
Issued 19 April 1995
Resolved
RE-STENCIL PORT ENGINE ROOM EMERGENCY ESCAPE.
Construction/Loadline
Issued 19 April 1995
Resolved
INSTALL VALVE HANDLE ON PORT GENERATOR COOLING WATER OVERBOARD.
Construction/Loadline
Issued 19 April 1995
Resolved
RENEW DECK DRAIN OVERBOARD HOSE IN PORT LAZARETTE.
Accommodation/Occupational Safety
Issued 19 April 1995
Resolved
REPLACE CRACKED WINDOW IN PILOT HOUSE.
Engineering
Issued 19 April 1995
Resolved
REPLACE COOLING WATER HOSE ON PORT INBOARD ENGINE.
Construction/Loadline
Issued 19 April 1995
Resolved
REWELD SHELL CONNECTION FOR STBD OUTBOARD MAIN ENGINE EXHAUST IN AREA OF POROSITY LEAK.
Construction/Loadline
Issued 19 April 1995
Resolved
MAKE STBD ENGINE ROOM HATCH WATERTIGHT.
Engineering
Issued 19 April 1995
Resolved
RENEW PORT OUTBOARD ENGINE COOLING WATER HOSE.
Electrical
Issued 19 April 1995
Resolved
UPPER DECK AFT DECK LIGHT, SECURE WIRING IN WEATHERTIGHT JUNCTION BOX.
Fire Fighting
Issued 19 April 1995
Resolved
PROVIDE SERVICE REPORT FOR FIXED FIRE EXTINGUISHING SYSTEM.
Accommodation/Occupational Safety
Issued 19 April 1995
Resolved
REPAIR OR REPLACE AFT STBD MAIN DECK DOOR TO WEATHER DECK.
Electrical
Issued 19 April 1995
Resolved
REMOVE BURNT WIRE BEHIND SCULLERY TABLE.
Construction/Loadline
Issued 19 April 1995
Resolved
MAKE PORT HOLD SPACE WATERTIGHT DECK SCUTTLE WATERTIGHT.
Accommodation/Occupational Safety
Issued 19 April 1995
Resolved
REPAIR LEAKING UPPER DECK WINDOW ON PORT SIDE NEAR STAIRCASE.
Unknown
Issued 19 April 1995
Resolved
RENEW HOSE ON #2 VOID (PORT) INBOARD OVERBOARD.
Construction/Loadline
Issued 27 March 1995
Resolved
REPAIR WASTED WELD IN WAY OF PORT INBOARD SHAFT TUBE TO THE SATISFACTION OFAN ATTENDING COAST GUARD MARINE INSPECTOR PRIOR TO CARRYING PASSENGERS.
Construction/Loadline
Issued 18 May 1994
Resolved
GRIND OUT AND REWELD FRACTURED WELDS AT JUNCTION OF FLOOR FRAMES AND SIDE SHELL FRAMES STARBOARD HULL IN SERVICE SPARE VOID (4 IN ALL).
Navigation
Issued 18 May 1994
Resolved
ADJUST RUDDER STOPS TO PREVENT RUDDER BLADES FROM COMING IN CONTACT WITH HULLS.
Navigation
Issued 18 May 1994
Resolved
REPAIR/REWELD FRACTURED RUDDER SUPPORT STANCHION (STARBOARD HULL).
Construction/Loadline
Issued 18 May 1994
Resolved
REPLACE RUBBER HOSE AND VALVE IN FIRE AND BILGE SUCTION LINE (STARBOARD HULL).
Construction/Loadline
Issued 18 May 1994
Resolved
REPLACE BOTH BILGE PUMPS.
Electrical
Issued 18 May 1994
Resolved
INSTALL MISSING CONSTAVOLT BATTERY CHARGER OR REMOVE WIRING FOR SAME (STARBOARD HULL).
Electrical
Issued 18 May 1994
Resolved
REPAIR ALL BATTERY KNIFE SWITCHES (SIX TOTAL).
Construction/Loadline
Issued 18 May 1994
Resolved
DRILL STOP, GRIND DOWN AND REWELD FRACTURE IN STARBOARD ENGINEROOM FORWARD BULKHEAD.
Electrical
Issued 18 May 1994
Resolved
RECONNECT OR REMOVE BATTERIES FROM BOTH SHIPS SERVICE GENERATOR BATTERY BOXES.
Documentation
Issued 18 May 1994
Resolved
PRIOR TO PLACING VESSEL IN SERVICE AND PRIOR TO CARRYING PASSENGERS, MAKE VESSEL AVAILABLE FOR INSPECTION FOR CERTIFICATION.
Construction/Loadline
Issued 18 May 1994
Resolved
AFFIX DRAFT MARKS IN CONTRASTING COLORS.
Construction/Loadline
Issued 18 May 1994
Resolved
CROP TO GOOD ALUMINUM AREA IN WAY OF MIDBODY HULL PLATE BENEATH GALLEY AREAWHERE PATCHED AND HOLED FROM BLASTING.
Deck/Cargo
Issued 18 May 1994
Resolved
MAKE ALL WEATHERDECK HATCHES WATERTIGHT.
Construction/Loadline
Issued 18 May 1994
Resolved
MAKE PERMANENT REPAIR TO TRIPPED FRAME IN WAY OF PORT HULL FUEL TANK FORWARD BULKHEAD, 100% WELD INSIDE AND OUT OF TANK. THEN SUBMIT FUEL TANK TO A 5 P.S.I. PRESSURE TEST.
Deck/Cargo
Issued 18 May 1994
Resolved
REMOVE/ISOLATE MISCELLANEOUS HOSE FITTINGS ON FUEL TRANSFER SYSTEM.
Engineering
Issued 18 May 1994
Resolved
MAKE PERMANENT REPAIRS TO ALL 4 MAIN ENGINE EXHAUST SYSTEMS.
Construction/Loadline
Issued 18 May 1994
Resolved
CLEAN ANY AND ALL OIL FROM BILGES OF BOTH HULLS.
Construction/Loadline
Issued 18 May 1994
Resolved
MAKE PERMANENT REPAIR TO DAMAGE ON BOTH PORT AND STARBOARD QUARTERS (RUBRAIL).
Navigation
Issued 18 May 1994
Resolved
[withheld — contains personal information; the deficiency system, dates, and resolution status are shown above]
Electrical
Issued 18 May 1994
Resolved
INSTALL ELECTRICAL MATTING IN FRONT OF BOTH MAIN ELECTRICAL DISTRIBUTION PANELS.
Accommodation/Occupational Safety
Issued 18 May 1994
Resolved
REPAIR EMERGENCY LIGHT IN FEMALE HEAD.
Lifesaving
Issued 18 May 1994
Resolved
PROVIDE AND REPLACE ALL 3 RING BUOYS.
Lifesaving
Issued 18 May 1994
Resolved
PROVIDE 10 ADULT AND 7 CHILD TYPE 1 PFD'S.
Lifesaving
Issued 18 May 1994
Resolved
REPLACE ALL HAND HELD VISUAL DISTRESS SIGNALS (FLARES).
Engineering
Issued 18 May 1994
Resolved
PROVE PROPER OPERATION OF BOTH EMERGENCY FUEL SHUTOFF VALVES.
Accommodation/Occupational Safety
Issued 18 May 1994
Resolved
PROVIDE AND POST WASTE MANAGEMENT PLAN.
Engineering
Issued 18 May 1994
Resolved
INSTALL EXHAUST LAGGING ON ALL FOUR MAIN DIESEL ENGINE PIPING._x001C_ _x001C_ _x001C_
Electrical
Issued 18 May 1994
Resolved
[withheld — contains personal information; the deficiency system, dates, and resolution status are shown above]
Engineering
Issued 18 May 1994
Resolved
PROVE PROPER OPERATION OF PORT OUTBOARD MAIN DIESEL ENGINE.
Accommodation/Occupational Safety
Issued 18 May 1994
Resolved
REPLACE BROKEN/CRACKED WINDOW ON 2ND DECK AFTER DOOR.
Electrical
Issued 18 May 1994
Resolved
REMOVE OR PROPERLY MOUNT 220 VOLT ELECTRICAL OUTLET IN GALLEY.
Electrical
Issued 3 May 1993
Resolved
Replace cord to food warmer in galley.
Electrical
Issued 3 May 1993
Resolved
Repair light at top of port dry stores compartment.
Lifesaving
Issued 3 May 1993
Resolved
Provide one additional orange smoke flare.
Fire Fighting
Issued 3 May 1993
Resolved
Perform annual servicing of fire extinguishing systems.
Electrical
Issued 3 May 1993
Resolved
Repair emergency light in starboard dry stores compartment and install globes on all lights in compartment.
Electrical
Issued 3 May 1993
Resolved
Repair broken conduit fitting on main disconnect for galley stove.
Fire Fighting
Issued 3 May 1993
Resolved
Provide one additional fire hose.
Electrical
Issued 3 May 1993
Resolved
Install globes and guards on outside deck lights as needed.
Electrical
Issued 3 May 1993
Resolved
Dead end cable or install junction box for wiring to previously used galleystove.
Lifesaving
Issued 3 May 1993
Resolved
Provide 22 additional child pfd's limited to not more than 180 total persons until completed.
Fire Fighting
Issued 5 May 1992
Resolved
Pressure test new fire hose using starboard fire pump once repairs are completed.
Engineering
Issued 5 May 1992
Resolved
Demonstrate operation of starboard (inboard) engine from wheelhouse.
Fire Fighting
Issued 5 May 1992
Resolved
Repair starboard fire pump.
Engineering
Issued 24 April 1992
Resolved
REPAIR PORT OUTBOARD MAIN ENGINE EXHAUST LEAK AND REPLACE MISSING LAGGING. (REMOVE SOFT PATCH)
Construction/Loadline
Issued 24 April 1992
Resolved
RENEW WASTED 4" BHD PIPE PENTRATION (DRAINAGE) BETWEEN STBD VOIDS #1 & #2.
Construction/Loadline
Issued 24 April 1992
Resolved
REPAIR LEAK TO 1 1/4" PVC PIPE ELBOW (DRAINAGE) IN PORT VOID #2.
Construction/Loadline
Issued 24 April 1992
Resolved
REWELD FRACTURED INBOARD DIAGONAL STEERING STRUT BRACKET STBD HULL.
Engineering
Issued 24 April 1992
Resolved
RENEW FLEX HOSE ON PORT GENERATOR EXHAUST PIPING TRANSITION TO THE HULL.
Engineering
Issued 24 April 1992
Resolved
RENEW FLEX HOSE TO PORT INBOARD MAIN ENGINE EXHAUST PIPING TRANSITION TO HULL.
Engineering
Issued 24 April 1992
Resolved
RENEW FLAME SCREEN ON PORT FUEL TANK VENT.
Fire Fighting
Issued 7 May 1991
Resolved
COMPLETE ANNUAL SERVICING OF FIXED CO2 SYSTEMS PRIOR TO CARRYING PASSENGERSAND NO LATER THAN 14MAY91.
Fire Fighting
Issued 7 May 1991
Resolved
REPLACE HOLED PIPE NIPPLE ON PORT FIRE MAIN PRIOR TO CARRYING PASSENGERS AND NO LATER THAN 14MAY91.
Engineering
Issued 7 May 1991
Resolved
STENCIL EMERGENCY FUEL SHUTOFFS PRIOR TO CARRYING PASSENGERS AND NO LATER THAN 14MAY91.
Engineering
Issued 7 May 1991
Resolved
REPAIR LEAKING RAW WATER PUMP ON PORT OUTBOARD PROPULSION ENGINE. TO BE COMPLETED NO LATER THAN 21MAY91.
Lifesaving
Issued 7 May 1991
Resolved
RENEW BATTERY IN RING BUOY LIGHT NO LATER THAN 21MAY91.
Fire Fighting
Issued 16 November 1990
Resolved
PROVIDE (06) METAL FIRE HOSE NOZZEL,S.
Lifesaving
Issued 16 November 1990
Resolved
PROVIDE (01) ONE RING BOUY.
Lifesaving
Issued 16 November 1990
Resolved
REMARK LIFE PRESERVE BOXES ON THE 03 DECK FORWARD.
Construction/Loadline
Issued 9 May 1990
Resolved
DECK HATCH COVERS ARE MISSING SECURING LINES.
Engineering
Issued 9 May 1990
Resolved
FUEL FILTER PAN REQUIRED FOR RACPR FUEL FILTERS IS MISSING.
Construction/Loadline
Issued 15 April 1987
Resolved
REPLACE PORT/STBD ENGINEROOM WEATHERDECK DOORS.
Accommodation/Occupational Safety
Issued 15 April 1987
Resolved
REPLACE HOLED FLEXIBLE HOSE ON GRAY WATER LINE IN #2 PORT VOID.
Engineering
Issued 19 November 1984
Resolved
RENEW FUEL TANK FLAMESCREENS FOR PORT FORWARD AND STARBOARD AFT FUEL TANKS.
Fire Fighting
Issued 19 November 1984
Resolved
PROVIDE ONE HAND PORTABLE FIRE PUMP.
Casualty record · 1
8 August 2002Routine · role: Involved in a Marine Casualty · activity 1663363
Each line is an incident investigation the Coast Guard recorded with this hull among the vessels involved, with the date and the classification the Coast Guard gave it, and the bridge, lock or dam the investigation names where it names one. Involvement is not fault. The investigation narrative is not published. Source: IIR, through 2026.
Ownership record
The Coast Guard's documentation record for this hull -- the Abstract of Title,
with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National
Vessel Documentation Center, files it here with its date, and every reader of this page gets it.