MAURY USCG vessel records Sign in
← All vessels

LE BARGE

LE BARGE is a 1974 passenger vessel (inspected). The Coast Guard has recorded 80 inspections since 1984, most recently in August 2025, along with 154 deficiencies and 1 casualty investigation in 2007.

Records from 1984 to 2025. Most recent: inspection, 27 August 2025.

Built
1974
Last inspected
27 August 2025
Documentation
Valid · documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

WDJ3550
Flag
UNITED STATES
367769040
Maury page id
psix-48097

Inspections, by type

…with no type recorded3
Years with a record 41 calendar years (1984–2025)
The 80 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Passenger Ship class in Maury's sources begin in 1977.

Documentation record

Registered dimensions (L × B × D)60.1 ft × 22.0 ft × 5.1 ft
Registered tonnagegross 48 / net 32
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
BuilderALUMSHIP CORP · JEANERETTE, LA, UNITED STATES · built 1974
Hull materialAluminum
PropulsionDiesel Reduction
Hull shapeNot recorded
Hull configurationNot recorded
Hailing portSARASOTA, FL
Trade endorsementsCoastwise, unrestricted
DocumentationValid · issued 4 December 2025 · expires 31 January 2027
Service, as the file records itPassenger (Inspected)
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it48 - Regulatory (Subpart C or D), Gross Ton
32 - Regulatory (Subpart C or D), Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 September 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.

Radio station licence

WDJ3550MMSI 367769040 · active · compulsorily equipped · granted 19 January 2017, expires 19 January 2027 · licensed under a name not among this hull’s recorded names (not shown)
WTX4401MMSI 367154370 · expired · compulsorily equipped · granted 7 December 2006, cancelled 4 March 2017
FCC Universal Licensing System ship-station file of 6 September 2026, matched to this hull on its US Official Number. Status and dates are the file’s own. The licensee is not read from the file and is not shown. A lapsed licence’s MMSI is still the number the vessel transmitted under while it was valid.

Inspection history · 80

27 August 2025 Administrative Inspection · Deficiency Check · Annual Inspection · Internal Structural Exam
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 8219332
6 August 2025 Drydock Exam · Internal Structural Exam · Deficiency Check · Hull Examination
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 8170911
2 October 2024 Annual Inspection
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 8004774
14 December 2023 In-Service Inspection
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 7807616
4 October 2023 Annual Inspection · Deficiency Check
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 7796668
16 August 2023 Internal Structural Exam · Examination of Repairs · Hull Examination
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 7725893
10 May 2023 In-Service Inspection
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 7668526
19 October 2022 Deficiency Check · Annual Inspection
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 7562321
25 August 2021 Deficiency Check · Hull Examination · COI Inspection · DAPI Audit · Internal Structural Exam · Administrative Inspection
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 7241640
1 July 2021 Administrative Inspection
Administrative · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 7241683
6 August 2020 Annual Inspection · DAPI Audit
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 7014867
13 November 2019 Administrative Inspection · Annual Inspection · DAPI Audit · Deficiency Check
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 6839618
5 September 2019 Examination of Repairs · Internal Structural Exam · Drydock Exam
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 6747446
13 September 2018 DAPI Audit · Deficiency Check · Administrative Inspection · Examination of Repairs · Annual Inspection
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 6517968
19 September 2017 Internal Structural Exam · Hull Examination
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 6266383
18 August 2017 DAPI Audit · Annual Inspection
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 6211964
5 September 2016 COI Inspection
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 5979526
14 October 2015 Deficiency Check · Annual Inspection
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 5742692
27 August 2014 Deficiency Check · DAPI Audit · Annual Inspection
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 4967016
19 June 2012 Administrative Inspection · Annual Inspection · DAPI Audit · Deficiency Check
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 4347742
26 September 2011 Simplified Stability Test · Administrative Inspection
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 4156599
2 September 2011 COI Inspection · DAPI Audit · Deficiency Check · Administrative Inspection
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 4132211
10 September 2010 Administrative Inspection · Hull Examination
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 3849124
13 July 2009 Administrative Inspection · Annual Inspection · Deficiency Check · DAPI Audit
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 3532984
4 September 2008 Drydock Exam
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 3316954
21 July 2008 Deficiency Check · Annual Inspection
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 3276800
11 June 2007 COI Inspection · Deficiency Check
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 2954113
27 January 2007 Type not recorded
No type recorded · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 3049843
7 September 2006 Hull Examination
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 2771465
14 August 2006 Annual Inspection · Deficiency Check
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 2742339
1 August 2005 Annual Inspection · Deficiency Check
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 2440182
10 September 2004 Hull Examination
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 2181239
9 July 2004 Annual Inspection
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 2099242
25 August 2003 Deficiency Check · Annual Inspection
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1860211
8 November 2002 Deficiency Check
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1713672
13 September 2002 Hull Examination
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1664978
10 July 2002 COI Inspection
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1640716
16 July 2001 Re-Inspection
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1366477
6 October 2000 Hull Examination · Re-Inspection
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1401318
27 October 1999 Deficiency Check
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 799083
13 July 1999 COI Inspection
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1378768
27 August 1998 Re-Inspection · Deficiency Check · Hull Examination
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1473032
25 July 1997 Administrative
Administrative · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1115278
25 July 1997 Re-Inspection · Simplified Stability Test
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1425943
28 August 1996 Hull Examination
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1392525
12 July 1996 COI Inspection
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1089315
7 August 1995 Re-Inspection · Deficiency Check
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 885954
11 October 1994 Deficiency Check
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1174834
9 September 1994 Re-Inspection
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1177370
31 August 1994 Hull Examination
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 862242
28 October 1993 Deficiency Check
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 830577
14 July 1993 COI Inspection
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 842896
26 October 1992 Deficiency Check
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 963174
17 September 1992 Hull Examination
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 935618
23 July 1992 Re-Inspection
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 955773
11 October 1991 Deficiency Check
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 942262
16 September 1991 Administrative
Administrative · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1252521
22 July 1991 Re-Inspection
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 940913
12 October 1990 Deficiency Check
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1225917
11 September 1990 Hull Examination · Deficiency Check
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 920116
16 July 1990 COI Inspection
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 905616
6 February 1990 Deficiency Check
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 903035
10 January 1990 Administrative
Administrative · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 907330
4 December 1989 Deficiency Check
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1229085
18 October 1989 Deficiency Check
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 887345
2 October 1989 Re-Inspection
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1024275
15 August 1989 Hull Examination
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1351216
20 June 1989 Administrative
Administrative · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1041222
26 January 1989 Administrative
Administrative · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 894762
3 January 1989 Deficiency Check
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1344839
25 October 1988 Type not recorded
No type recorded · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 890273
19 September 1988 Re-Inspection
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 887295
25 July 1988 Hull Examination
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1037268
2 October 1987 Administrative
Administrative · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1012151
20 July 1987 COI Inspection · Deficiency Check
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1030833
8 June 1987 Deficiency Check · Hull Examination
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1309510
19 August 1986 Re-Inspection
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1296339
4 January 1986 Credit Drydock
Administrative · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1304664
16 October 1985 Re-Inspection
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1297316
3 December 1984 Type not recorded
No type recorded · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 977417

Deficiency record · 154

10 - Safety of Navigation › N/A - No Subsystem › Lights, shapes, sound-signals
Issued 18 November 2025 Resolved
All vessels must have navigation lights that are in compliance with the applicable sections of the International and Inland Navigation Rules. Starboard sidelight was non-operational. Replace sidelight to the satisfaction of the attending MI prior to carriage of passengers. 46 CFR 183.420
Action required: 701 - Prior to carriage of passengers/cargo
Due 18 November 2025
Resolved 10 December 2025
Resolution: Starboard sidelight has been repaired and was verified by MI.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 2 October 2024 Resolved
46 CFR 180.71 (a) An adult life jacket must be provided for each person carried on board a vessel. MI observed 23 adult size life jackets that needs to be replaced. CODE 705: Vessel is restricted to carrying 126 people that would require and adult size life jacket.
Action required: 705 - Other - as specified
Due 2 October 2024
Resolved 1 November 2024
Resolution: Received pictures of new life jackets.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 2 October 2024 Resolved
46 CFR 185.604 (h) Each life jacket must be marked with Type I retroreflective material. MI observed 13 adult sized life jackets that need new retroreflective material.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 16 October 2024
Resolved 1 November 2024
Resolution: Received pictures of life jackets with new retroreflective material.
01 - Certificates & Documentation › 011 - Ships Certificates › USCG Certificate of Documentation (COD)
Issued 4 October 2023 Resolved
Any vessel of at least five net tons which engages in coastwise trade on the navigable waters of the United States must have a Certificate of Documentation onboard. COD expired. 46 CFR 67.7
Action required: 701 - Prior to carriage of passengers/cargo
Due 4 October 2023
Resolved 4 October 2023
Resolution: Received proof that COD renewal was paid for.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 4 October 2023 Resolved
An adult life jacket must be provided for each person carried onboard. Vessel missing 6 adult life jackets; max persons allowed reduced to 143. 46 CFR 180.71(a)
Action required: 705 - Other - as specified
Due 4 October 2023
Resolved 9 October 2023
Resolution: 6 additional adult life jackets provided.
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 4 October 2023 Resolved
Portable fire extinguishers shall be installed and located to the satisfaction of the Officer in Charge, Marine Inspection. CO2 fire extinguisher in the main accommodation space is not mounted. 46 CFR 181.30-10(b)
Action required: 16 - Rectify deficiencies w/in 14 days
Due 18 October 2023
Resolved 9 October 2023
Resolution: Extinguisher mounted.
08 - Alarms › N/A - No Subsystem › Other (alarms)
Issued 4 October 2023 Resolved
A visual and audible alarm must be provided at the operating station to indicate a high water level in a space with a through-hull fitting below the deepest load waterline. Forward AC space bilge high water alarm inoperative. 46 CFR 182.530(a)
Action required: 16 - Rectify deficiencies w/in 14 days
Due 18 October 2023
Resolved 4 October 2023
Resolution: Alarm repaired by the end of inspection.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 19 October 2022 Resolved
An adult life jacket must be provided for each person carried on board a vessel. OCMI counted 26 life jackets that could no longer meet the requirements to be in service. Vessel is restricted to carrying 123 passengers including crew until in full compliance with the amount required on vessels COI. 46 CFR 180.71(a)
Action required: 16 - Rectify deficiencies w/in 14 days
Due 2 November 2022
Resolved 17 November 2022
Resolution: Vessel has purchased 26 new lifejackets and put them into service.
02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 19 October 2022 Resolved
The number of penetrations in a watertight bulkhead must be minimized. A penetration in a watertight bulkhead must be as high and as far inboard in the bulkhead as practicable, and made watertight. OCMI found the cable runs did not have sufficient amount of packing to make a quality seal. 46 CFR 179.320(c)
Action required: 16 - Rectify deficiencies w/in 14 days
Due 2 November 2022
Resolved 28 October 2022
Resolution: Pictures rectifying deficiency sent.
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 19 October 2022 Resolved
Portable fire extinguishers shall be installed and located to the satisfaction of the Officer in Charge, Marine Inspection. OCMI found fire extinguisher in the engine room to be mounted in a bracket that was not safely secured. 46 CFR 181.30-10(B)
Action required: 16 - Rectify deficiencies w/in 14 days
Due 2 November 2022
Resolved 28 October 2022
Resolution: Pictures rectifying deficiency sent.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Operation of machinery
Issued 25 August 2021 Resolved
A limit switch to stop the steering gear before it reaches the rudder stops required by paragraph (e) of this section. During operational testing of the steering system, whenever steering gear was pressed hard STBD, the port tiller arm was contacting the rudder stop and the rudder stop would deflect back. At the next DD, disassemble rudder and associated pins and bolts to determine any damage caused buy this as well as inspect all welds and potential structural areas that may have been affecting by the flexing of the rudder stop. Additionally provide proposal to correct the tiller from impacting the rudder stop. 46CFR 182.610(e)(5)
Action required: 705 - Other - as specified
Due 25 August 2021
Resolved 2 October 2021
Resolution: Rudder tube inserts and posts installed, all sat.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 25 August 2021 Resolved
Each life jacket must be marked with Type I retroflection tape material. During the life jacket inspection there was 7 life jackets identified where the retro reflective tape was serviceable. Passenger count is limited to 138 until tape or jackets are replaced. 46 CFR 185.604(h)
Action required: 50 - Rectify deficiencies w/in 30 days
Due 25 September 2021
Resolved 24 September 2021
Resolution: Life jackets had retro reflective tape replaced.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 13 November 2019 Resolved
An adult life jacket must be provided for each person carried on board a vessel. 12 life jackets were found to be unserviceable and were destroyed in the presence of MI. 141 servicable life jackets (adult) and > 15 child life jackets remain. Vsl restricted to 137 passengers with manning remaining the same. 46 CFR 180.71
Action required: 16 - Rectify deficiencies w/in 14 days
Due 27 November 2019
Resolved 19 November 2019
Resolution: 12 life jackets were replaced, labeled, and properly stowed.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 13 November 2019 Resolved
All vessels shall be provided with a satisfactory arrangement for draining any watertight compartment other than small buoyancy compartments. The fixed bilge pump and piping system was not operational during this inspection. Vsl was unable to dewater forepeak or lazarette . Additionally during test of bilge piping in lazarette the bilge pipe broke, rendering it inoperable. 46 CFR 182.25-1(a)
Action required: 701 - Prior to carriage of passengers/cargo
Due 13 November 2019
Resolved 19 November 2019
Resolution: Bilge pump check valves were replaced in the forepeak and lazarette. Piping was replaced as original in lazarette. Full system was tested with no issues.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 13 November 2019 Resolved
Each ring life buoy on a vessel must be approved in accordance with 160.050 in subchapter Q. The grabline shall be 3/8 inch diameter polyethyline, polypropyline, or other suitable bouyant type. The grab lines on both life rings were deteriorated. Replace. 46 CFR 180.70(b)(1)
Action required: 16 - Rectify deficiencies w/in 14 days
Due 27 November 2019
Resolved 2 December 2019
Resolution: Grab lines replaced as original.
11 - Life Saving Appliances › N/A - No Subsystem › Rescue boats
Issued 13 November 2019 Resolved
The vessel must be sufficiently maneuverable, arranged, and equipped to allow the crew to recover a helpless person from the water. During man overboard drill, a crew member fell overboard. Crew was unable to demonstrate recovery of helpless person. Propose plan and demonstrate prior to carrying passengers. 46 CFR 180.210
Action required: 701 - Prior to carriage of passengers/cargo
Due 13 November 2019
Resolved 19 November 2019
Resolution: Rescue ladder inspected for workmanship, all sat. While underway, witnessed man overboard drill with 2 crewmembers and captain conning the vessel.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 13 November 2019 Resolved
Electrical installations shall be reasonably safe from electrical shock of personnel. Exposed wires found on top deck, port side lighting box. Repair. 46 CFR 183.01-5
Action required: 16 - Rectify deficiencies w/in 14 days
Due 27 November 2019
Resolved 19 November 2019
Resolution: Lighting box with exposed wires was replaced.
02 - Structural Conditions › N/A - No Subsystem › Beams, frames, floors-corrosion
Issued 13 November 2019 Resolved
Scantlings, material, fastenings, workmanship, and arrangements of vessel shall be such as to provide for safe operation. Center stantion in forepeak has a broken weld at bottom connection to the hull. Repair. 46 CFR 177.01-5
Action required: 16 - Rectify deficiencies w/in 14 days
Due 27 November 2019
Resolved 2 December 2019
Resolution: Broken weld was grinded out and welded to the satisfaction of the MI.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 13 September 2018 Resolved
Where flexible nonmetallic hose is permitted for use in piping systems by this section, it must meet SAE Standard J–1942, ‘‘Hose and Hose Assemblies for Marine Applications,’’ or be specifically approved by the Commandant. Flexible hose installed on starboard side bilge piping forward of starboard main engine. Provide repair proposal. - 46CFR182.720(e)
Action required: 16 - Rectify deficiencies w/in 14 days
Due 27 September 2018
Resolved 3 October 2018
Resolution: Operator replaced flex hose with approved type.
02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 13 September 2018 Resolved
Vessels shall be inspected for compliance with the standards required by this subchapter. For items not covered by standards in this subchapter, inspection shall be in accordance with standards acceptable to the OCMI, as good marine practice. 46CFR176.25-1(a) Discovered hole in top of sewage tank. Repair. - 46CFR178.25-1(a)
Action required: 16 - Rectify deficiencies w/in 14 days
Due 27 September 2018
Resolved 3 October 2018
Resolution: Verified weld repairs to top of tank.
Engineering › Steering Gear System › Pin
Issued 6 September 2016 Resolved
Replace cotter pin on port rudder stock. Cotter pin missing IAW 46 CFR 182.30-1
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 6 September 2016
Fire Fighting › Remote Fuel Shutoff › General
Issued 6 September 2016 Resolved
Lable location of emergency fuel shut off and direction of turn. Make operable from outside machinery space IAW 46 cfr 185.608
Action required: 705 - Other - as specified
Due 20 September 2016
Resolved 16 September 2016
Lifesaving › Lifejacket/PFD (Type I) › Condition
Issued 14 October 2015 Resolved
As per 46 CFR 180.71, the vessel must be fitted with an approved lifejacket for each person allowed on board. During the inspection 13 adult lifejackets we destroyed due to degradation. Provide the appropriate number of lifejackets required by the COI. The vessel is restricted to carrying no more than 136 persons on board.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 14 October 2015
Resolved 15 October 2015
Resolution: The master provided the vessel with the required amount of adult lifejackets.
Lifesaving › Lifejacket/PFD (General) › Storage
Issued 14 October 2015 Resolved
Re-label the child lifejacket stowage with the appropriate number provided – 25.
Condition: Invalid
Action required: 705 - Other - as specified
Due 21 October 2015
Resolved 2 November 2015
Electrical › Electric Supply System (service) › Cable
Issued 14 October 2015 Resolved
As per 46 CFR 183.340 the stern light is not fitted with a cable suitable for marine service/stranded wire. Replace the solid copper wire with a stranded wire.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 21 October 2015
Resolved 2 November 2015
Fire Fighting › Fire Pumps › Power Source
Issued 14 October 2015 Resolved
As per 46 CFR 183.10-20 the control wire for the fire pump is not suitable for marine service. Provide the pump controls with a marine grade wire.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 21 October 2015
Resolved 2 November 2015
Engineering › Generator (propulsion/auxiliary-electric) › Contactor
Issued 27 August 2014 Resolved
Replace Starboard generator motor mount. IAW 46CFR176.804
Action required: 705 - Other - as specified
Due 11 September 2014
Resolved 15 September 2014
Resolution: O/O replaced all four motor mounts on starboard generator.
Documentation › Logs/Records › MIS Form
Issued 27 August 2014 Resolved
Provide current MIS Report. IAW 46CFR16
Action required: 705 - Other - as specified
Due 11 September 2014
Resolved 15 September 2014
Resolution: O/O provided MIS report.
Stability › Watertight Integrity › General
Issued 27 August 2014 Resolved
Provide watertight material/packing for electrical wiring in between water and fuel tank compartments. IAW 46CFR179.320
Action required: 705 - Other - as specified
Due 11 September 2014
Resolved 27 August 2014
Resolution: Acceptable packing provided for watertight compartment in between water and fuel tank compartment.
Lifesaving › Lifebuoys › Stowage
Issued 27 August 2014 Resolved
Provide quick release clip for lifebuoy waterlight. IAW 46CFR180.71(d)(3)
Action required: 705 - Other - as specified
Due 11 September 2014
Resolved 27 August 2014
Resolution: Quick replease clip was provided and installed on lifebuoy.
Engineering › Shafting/Propeller Arrangements › Propeller Shaft
Issued 18 June 2012 Resolved
Found clamp on stbd prop shaft worn beyond repair. Replace with new clamp IAW 46CFR176.814
Condition: Improper/Lack of Maintenance
Due 3 July 2012
Resolved 2 July 2012
Resolution: replaced with new clamp.
Engineering › Fuel Oil Storage/Transfer System › Filter/Strainer
Issued 18 June 2012 Resolved
Hydraulic filter in engine room in need of service. Service hydraulic filter IAW 46CFR182.610.
Condition: Improper/Lack of Maintenance
Due 3 July 2012
Resolved 2 July 2012
Resolution: replaced with new hydraulic filter.
Electrical › Electrical Distribution System (service) › Wiring
Issued 18 June 2012 Resolved
Found unproper dead ending of wiring on port generator in engine room. Properly dead end wiring IAW 46CFR183.10-20
Condition: Improper/Lack of Maintenance
Due 3 July 2012
Resolved 2 July 2012
Resolution: properly dead ended wiring with compression type fitting.
Electrical › Electrical Distribution System (service) › Cable
Issued 18 June 2012 Resolved
Remove all extension cords on vessel IAW 46CFR183.330
Condition: Improper Installation
Due 3 July 2012
Resolved 2 July 2012
Resolution: removed all extension cords.
Navigation › Piloting/Steering › Marine Charts
Issued 18 June 2012 Resolved
Found nautical chart out of date & coast pilot non existent. Correct chart and update coast pilot to within one year of this date IAW 46CFR184.420.
Condition: Improper/Lack of Maintenance
Due 3 July 2012
Resolved 2 July 2012
Resolution: replaced with new chart and new coast pilot.
Navigation › Piloting/Steering › Coast Guard Light List
Issued 2 September 2011 Resolved
VESSEL'S U.S. COAST PILOT, COAST GUARD LIGHT LIST, AND USCG COLREGS/NAV RULES ARE OUT DATED. A VESSEL MUST CARRY ADEQUATE AND UP-TO-DATE U.S. COAST PILOT, COAST GUARD LIGHT LIST, AND USCG COLREGS/NAV RULES IAW 46 CFR 184.420. REPLACE WITH UP-TO-DATE PUBLICATIONS TO THE SATISFACTION OF USCG MARINE INSPECTOR.
Action required: 705 - Other - as specified
Due 9 September 2011
Resolved 8 September 2011
Resolution: Received email of pictures of all new pubs & charts.
Lifesaving › Lifejacket/PFD (Type I) › Retroreflective Material
Issued 2 September 2011 Resolved
SEVEN (7) ADULT PFD'S FOUND WITH DETERIORATED RETROREFLECTIVE MATERIAL. EACH PFD MUST BE MARKED WITH TYPE I RETROREFLECTIVE MATERIAL IAW 46 CFR 185.604(h). REPLACE WITH APPROVED RETROREFLECTIVE MATERIAL. VESSEL IS LIMITED TO 142 ADULT PERSONS.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 9 September 2011
Resolved 8 September 2011
Resolution: Received email pictures of new and renewed lifejackets.
Lifesaving › Lifejacket/PFD (Type I) › Quantity
Issued 13 July 2009 Resolved
PASSENGER COUNT IS REDUCED TO 139 PASSENGERS AND 4 CREW UNTIL ADDITIONAL LIFEJACKETS ARE PLACED ONBOARD.
Action required: 705 - Other - as specified
Resolved 6 August 2009
Lifesaving › Lifebuoys › Serviceable
Issued 21 July 2008 Resolved
REPLACE RING LIFEBUOY.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 21 July 2008
Navigation › Collision/Grounding Avoidance › Navigation Lights
Issued 21 July 2008 Resolved
MOVE FLAG IWO STERN LIGHT.
Due 28 July 2008
Resolved 1 August 2008
Engineering › Generator (propulsion/auxiliary-electric) › Junction Box
Issued 21 July 2008 Resolved
PROPERLY ENCLOSE GAUGE PANEL FOR STBD GENERATOR AND SUPPORT CABLE PROPERLY.
Due 4 August 2008
Resolved 1 August 2008
Electrical › Electric Supply System (service) › Cable
Issued 21 July 2008 Resolved
REMOVE DEAD END WIRES THROUGHT OUT THE VESSEL.
Due 4 August 2008
Resolved 1 August 2008
Fire Fighting › Portable Dry Chemical Fire Extinguisher › Location
Issued 21 July 2008 Resolved
INSTALL FIRE EXTINGUISHER ON SECOND DK.
Due 28 July 2008
Resolved 1 August 2008
Accommodation/Occupational Safety › Medical/First Aid › Medicine Chest
Issued 11 June 2007 Resolved
REPLACE FIRST AID KIT WITH CG APPROVED KIT.
Due 15 June 2007
Resolved 20 July 2007
Resolution: CG FIRST AID KIT WAS PURCHASED.
Operations/Management › Navigation Safety › Carriage of Charts and Publications
Issued 11 June 2007 Resolved
PROVIDE UP TO DATE NAVIGATION PUBLICATIONS AS NEEDED.
Condition: Unknown
Due 15 June 2007
Resolved 15 June 2007
Resolution: New publications were downloaded and placed onboard.
Construction/Loadline › Structures › Superstructure
Issued 11 June 2007 Resolved
REPAIR THE THREE CRACKED WINDOWS ON THE MAIN DECK PORT AND STBD SIDE AS DISCUSSED.
Due 22 June 2007
Resolved 20 July 2007
Resolution: NEW WINDOWS WERE INSTALLED.
Construction/Loadline › Structures › Superstructure
Issued 7 September 2006 Resolved
Repair the three cracked windows as discussed. Two to PORT and one to STBD on the main deck.
Condition: Design Flaw
Action required: 705 - Other - as specified
Due 7 October 2006
Resolved 20 July 2007
Resolution: Visited vsl and observed new glass installed.
Engineering › Bilge Water Management System › Interface Detector
Issued 14 August 2006 Resolved
Label bilge high level alarm lights.
Condition: Improper/Lack of Maintenance
Due 21 August 2006
Resolved 22 August 2006
Resolution: LABELED, SAT
Lifesaving › Lifejacket/PFD (General) › Storage
Issued 14 August 2006 Resolved
Label FWD life jacket box with "ADULT" as discussed. They did not have the style of life preservers maked in box.
Condition: Improper/Lack of Maintenance
Due 21 August 2006
Resolved 22 August 2006
Resolution: CORRECTED
Electrical › Electric Supply System (service) › Cable
Issued 14 August 2006 Resolved
Remove all wire nuts and provide butt connectors throughout vessel. (ex: under bridge) They have been re-wiring systems and not properly securing wire runs and using improper wire connections.
Condition: Improper/Lack of Maintenance
Due 21 August 2006
Resolved 22 August 2006
Resolution: CORRECTED AND INSPECTED, SAT
Engineering › Bilge Water Management System › Valve
Issued 14 August 2006 Resolved
Properly secure FWD reach rod connection for bilge suction valve. Deck connection to reach rod fell off during inspection.
Condition: Improper/Lack of Maintenance
Due 14 August 2006
Resolved 22 August 2006
Resolution: REPAIRED, SAT
Engineering › Diesel Engine (propulsion-reduction gear) › Valve
Issued 14 August 2006 Resolved
Place cap/plug on lube oil drain line for PORT engine. Oil drain line has a ball valve at the end of suction line with no means of stopping oil drainage if the valve became open.
Condition: Design Flaw
Due 14 August 2006
Resolved 22 August 2006
Resolution: CORRECTED, SAT
Operations/Management › Drills/Instruction › Man Overboard Recovery
Issued 14 August 2006 Resolved
Re-write emergency instructions for vessel, and post, as discussed. (ex: person OVBD drill) Instructions did not cover donning life jackets.
Condition: Improper/Lack of Maintenance
Due 21 August 2006
Resolved 22 August 2006
Resolution: CORRECTED AND POSTED, SAT.
Electrical › Electric Supply System (service) › Battery Installation
Issued 14 August 2006 Resolved
Prior to the carriage of passengers, tighten all battery terminal connections.
Condition: Improper/Lack of Maintenance
Due 14 August 2006
Resolved 14 August 2006
Resolution: CORRECTED PRIOR TO OUOR DEPARTURE.
Lifesaving › Lifebuoys › Self-igniting Lights
Issued 1 August 2005 Resolved
Provide a lanyard for float light IAW 46CFR180.70(d). Float light had no line attached as outlined in the CFR site.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 8 August 2005
Resolved 26 August 2005
Resolution: CORRECTED.
Engineering › Fuel Oil Service System › Valve
Issued 1 August 2005 Resolved
Label emergency fuel shut-off valve located on STBD side, amidship.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 8 August 2005
Resolved 26 August 2005
Resolution: CORRECTED
Electrical › Lighting (service) › Conductor
Issued 1 August 2005 Resolved
Remove romex wiring IWO port head and install boat cable and approved junction box IAW 46CFR183.340. They have added an outlet utilizing the wrong type of electrical wiring.
Condition: Placed in Improper Service
Action required: 705 - Other - as specified
Due 1 October 2005
Resolved 26 August 2005
Resolution: CORRECTED.
Lifesaving › Hand Flares › Expired
Issued 1 August 2005 Resolved
Prior to the carriage of passengers, provide 3 additional hand held flares. Three flares have expired.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 1 August 2005
Resolved 26 August 2005
Resolution: CORRECTED.
Operations/Management › Drills/Instruction › Man Overboard Recovery
Issued 1 August 2005 Resolved
Provide emergency instruction for vessel IAW 46CFR185.510. POC could not find instruction.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 8 August 2005
Resolved 26 August 2005
Resolution: CORRECTED.
Electrical › Electrical Distribution System (service) › Cable
Issued 1 August 2005 Resolved
Remove all extension cords from vessel and properly wire vessel equipment. (i.e fish tank, ice machine cooling fan)
Condition: Placed in Improper Service
Due 1 September 2005
Resolved 26 August 2005
Resolution: CORRECTED.
Fire Fighting › Portable CO2 Fire Extinguisher › Service
Issued 9 July 2004 Resolved
HYDROSTATIC TEST ALL PORTABLE CO2 CYLINDERS AS NEEDED.
Due 1 August 2004
Resolved 10 September 2004
Resolution: SAT
Navigation › Collision/Grounding Avoidance › Navigation Lights
Issued 9 July 2004 Resolved
REPLACE PORT AND STARBOARD RUNNING LIGHT LENSES.
Due 1 August 2004
Resolved 10 September 2004
Resolution: SAT
Lifesaving › Lifejacket/PFD (General) › Marking
Issued 9 July 2004 Resolved
PROPERLY LABEL ALL CHILD SIZED LIFEJACKETS WITH VESSEL NAME.
Due 1 August 2004
Resolved 10 September 2004
Resolution: SAT
Navigation › Collision/Grounding Avoidance
Issued 25 August 2003 Resolved
REPAIR STARBOARD RUNNING LIGHT PRIOR TO OPERATION AT NIGHT OR REDUCED VISIBILITY. LEGACY COMPONENT DESC: Navigation Lights
Due 2 September 2003
Resolved 4 September 2003
Resolution: FAX
Deck/Cargo › Holds/Tanks
Issued 25 August 2003 Resolved
INSTALL KEEPER ON LAZARETTE HATCH COVER. LEGACY COMPONENT DESC: Hatch Cover
Due 2 September 2003
Resolved 4 September 2003
Resolution: FAX
Operations/Management › Drills/Instruction
Issued 25 August 2003 Resolved
POST EMERGENCY INSTRUCTIONS. LEGACY COMPONENT DESC: Emergency Procedures
Due 2 September 2003
Resolved 4 September 2003
Resolution: FAX
Electrical › Electric Generation Source (service)
Issued 13 September 2002 Resolved
Repair oil leak on PORT GENSET. LEGACY COMPONENT DESC: Oil Leak on GENSET
Due 5 October 2002
Resolved 8 November 2002
Accommodation/Occupational Safety › Occupational Safety
Issued 10 July 2002 Resolved
REPAIR 4 BROKEN WINDOWS IN MAIN SALON. LEGACY COMPONENT DESC: Windows
Condition: Unknown
Due 2 August 2002
Resolved 8 November 2002
Electrical › Electrical Distribution System (service)
Issued 10 July 2002 Resolved
REPAIR LATCH ON STBD ENGINE ROOM ACCESS DISTRIBUTION PANEL. LEGACY COMPONENT DESC: Panelboard
Condition: Improper/Lack of Maintenance
Due 2 August 2002
Resolved 19 July 2002
Accommodation/Occupational Safety › Occupational Safety
Issued 10 July 2002 Resolved
REMOVE FLAMMABLES FROM ENGINE ROOM PRIOR TO CARRIAGE OF PASSENGERS. LEGACY COMPONENT DESC: Flammables
Condition: Improper/Lack of Maintenance
Due 2 August 2002
Resolved 19 July 2002
Resolution: REMOVED.
Engineering › Sea-water System (primary cooling)
Issued 10 July 2002 Resolved
REMOVE PVC PIPING FROM KEEL COOLER AND PLUG WITH METALLIC CAP OR VALVE PRIOR TO CARRIAGE OF PASSENGERS. LEGACY COMPONENT DESC: Piping
Condition: Improper Installation
Due 2 August 2002
Resolved 19 July 2002
Resolution: REMOVED AND CAPPED.
Operations/Management › Drills/Instruction
Issued 10 July 2002 Resolved
INITIATE CREW TAINING/DRILL LOGS.
Condition: Placed in Improper Service
Due 2 August 2002
Resolved 19 July 2002
Resolution: STARTED.
Electrical › Lighting (service)
Issued 10 July 2002 Resolved
REMOVE/REPAIR SPOT LIGHT FIXTURES ON UPPER DECK IN WAY OF PORT/STARBOARD LEGACY COMPONENT DESC: Outlet Box
Condition: Improper/Lack of Maintenance
Due 17 July 2002
Resolved 19 July 2002
Resolution: REPAIRED
Electrical › Lighting (service)
Issued 10 July 2002 Resolved
INSTALL WET LOCATION OUTLET COVER ON AFT PORT PILOT HOUSE. LEGACY COMPONENT DESC: Outlet Box
Condition: Improper/Lack of Maintenance
Due 17 July 2002
Resolved 19 July 2002
Resolution: INSTALLED
Electrical › Lighting (service)
Issued 10 July 2002 Resolved
REPAIR LIGHT DIFFUSER ON BRIDGE LIGHTING. LEGACY COMPONENT DESC: Lighting Fixture
Condition: Improper/Lack of Maintenance
Due 17 July 2002
Resolved 19 July 2002
Resolution: NEW DIFFUSER
Engineering › Bilge Water Management System
Issued 10 July 2002 Resolved
PROVE PROPER OPERATION OF BILGE MANIFOLD SYSTEM. OPERATION WITH ELECTRIC SUBMERSIBLE PUMP FOR EMERGENCIES PERMISSIBLE UNTIL REPAIR OF MANIFOLD SYSTEM. PASSENGERS REDUCED TO 49. LEGACY COMPONENT DESC: Manifold
Condition: Unknown
Due 17 July 2002
Resolved 19 July 2002
Resolution: WITNESSED OPERATION.
Electrical › Lighting (service)
Issued 10 July 2002 Resolved
REMOVE POWER STRIP SUPPLYING POWER TO AUXILIARY LIGHTING ON 01 DECK PRIOR TO CARRIAGE OF PASSENGERS. LEGACY COMPONENT DESC: Lighting Feeder
Condition: Placed in Improper Service
Due 2 August 2002
Resolved 19 July 2002
Resolution: REMOVED
Documentation
Issued 6 October 2000 Resolved
PROVIDE CURRENT COPY OF FCC RADIOTELEPHONE SAFETY CERTIFICATE.
Condition: Unknown
Due 13 October 2000
Resolved 23 October 2000
Engineering
Issued 6 October 2000 Resolved
MO MACHINERY GUARD PRESENT IWO STBD ENGINE, BILGE PUMP BELTS. PROVIDE GUARDS IWO.
Condition: Unknown
Due 2 November 2000
Resolved 20 November 2000
Accommodation/Occupational Safety
Issued 6 October 2000 Resolved
WINDOWS IN PASSENGER SPACE CRACKED; REPLACE AS ORIGIONAL.
Condition: Unknown
Due 11 October 2000
Resolved 15 October 2000
Fire Fighting
Issued 13 July 1999 Resolved
PROPERLY MOUNT PORTABLE CO2 FIRE EXTINGUISHERS.
Condition: Unknown
Due 13 July 1999
Resolved 13 July 1999
Accommodation/Occupational Safety
Issued 13 July 1999 Resolved
REPLACE WASTE RECEPTICLES THROUGHOUT VESSEL WITH NON-FLAMABLE TYPE.
Condition: Unknown
Due 13 July 1999
Resolved 13 July 1999
Lifesaving
Issued 13 July 1999 Resolved
CONDUCT DRILLS (MOB AND FIRE) IN PRESENCE OF MARINE INSPECTOR UPON APPROVALOF RESCUE PLATFORM. CONDUCT TEST OF FIREPUMP DURING DRILL.
Condition: Unknown
Due 13 July 1999
Resolved 13 July 1999
Electrical
Issued 13 July 1999 Resolved
PROPERLY MOUNT COFFEE MAKER, STEAM TRAY AND WARMER, TO PREVENT MOVEMENT.
Condition: Unknown
Due 13 July 1999
Resolved 13 July 1999
Electrical
Issued 13 July 1999 Resolved
INSTALL WOOD BLOCKING AROUND BATTERIES TO PREVENT MOVEMENT.
Condition: Unknown
Due 13 July 1999
Resolved 13 July 1999
Electrical
Issued 13 July 1999 Resolved
MAKE RECEPTICLES IN WET LOCATIONS DRIP PROOF AND REMOVE ALL EXTENSION POWERSTRIPS/CORDS FROM THE VESSEL. ALL WIRING AND RECEPTICLES MUST BE IAW 46CFR SUBCHAPTER T.
Condition: Unknown
Due 13 July 1999
Resolved 13 July 1999
Navigation
Issued 13 July 1999 Resolved
PROVIDE CURRENT COPY OF THE NAVIGATION RULES OF THE ROAD.
Condition: Unknown
Due 13 July 1999
Resolved 13 July 1999
Construction/Loadline
Issued 13 July 1999 Resolved
MAKE VESSEL AVAILABLE TO CONDUCT INTERNAL STRUCTURAL EXAM IAW MOC POLICY LETTER 3-97.
Condition: Unknown
Due 13 July 1999
Resolved 13 July 1999
Lifesaving
Issued 13 July 1999 Resolved
INSTALL DONNING PLACARDS FOR BOTH TYPES OF PFD'S ON ALL PASSENGER DECKS.
Condition: Unknown
Due 13 July 1999
Resolved 13 July 1999
Construction/Loadline
Issued 13 July 1999 Resolved
PAINT DRAFT MARKS IN CONTRASTING COLOR TO VESSELS HULL.
Condition: Unknown
Due 13 July 1999
Resolved 13 July 1999
Documentation
Issued 13 July 1999 Resolved
PROVIDE COPY OF STABILITY LETTER AND POST IN THE PILOTHOUSE.
Condition: Unknown
Due 13 July 1999
Resolved 13 July 1999
Construction/Loadline
Issued 13 July 1999 Resolved
INSTALL HIGH BILGE LEVEL ALARMS IAW 46 CFR 182.530.
Condition: Unknown
Due 13 July 1999
Resolved 13 July 1999
Lifesaving
Issued 13 July 1999 Resolved
SUBMIT FOR APPROVAL A METHOD TO CONDUCT MAN OVERBOARD RESCUE AND DEMONSTRATE.
Condition: Unknown
Due 13 July 1999
Resolved 13 July 1999
Electrical
Issued 13 July 1999 Resolved
INSTALL CAPTIVE TERMINALS ON BATTERY CONNECTORS AND FUSE WHERE REQUIRED.
Condition: Unknown
Due 13 July 1999
Resolved 13 July 1999
Lifesaving
Issued 13 July 1999 Resolved
PROVIDE FIRST AID KIT IAW 46 CFR 160.041.
Condition: Unknown
Due 13 July 1999
Resolved 13 July 1999
Electrical
Issued 13 July 1999 Resolved
PROVIDE 2ND PORTABLE LIGHT AT ENTRANCE TO THE MACHINERY SPACE.
Condition: Unknown
Due 13 July 1999
Resolved 13 July 1999
Documentation
Issued 13 July 1999 Resolved
SUBMIT COPY OF DRUG TESTING PROGRAM IAW 46CFR16 AND COPY OF ANNUAL MIS REPORT.
Condition: Unknown
Due 13 July 1999
Resolved 13 July 1999
Documentation
Issued 25 July 1997 Resolved
[withheld — contains personal information; the deficiency system, dates, and resolution status are shown above]
Condition: Unknown
Due 11 August 1997
Resolved 18 February 1998
Lifesaving
Issued 25 July 1997 Resolved
MARK PFD STOWAGE LOCKERS WITH QUANTITY AND SIZE OF PFD'S CONTAINED.
Condition: Unknown
Due 11 August 1997
Resolved 18 February 1998
Lifesaving
Issued 25 July 1997 Resolved
REMOVE ALL FLAMMABLE STORES FROM VSL OR INSTALL FLAMMABLE STORES LOCKER IAW46 CFR 181.20-5.
Condition: Unknown
Due 31 July 1997
Resolved 31 July 1997
Electrical
Issued 25 July 1997 Resolved
REMOVE ALL EXTENSION CORDS FROM VESSELS ELECTRICAL SYSTEM.
Condition: Unknown
Due 11 August 1997
Resolved 18 February 1998
Unknown
Issued 25 July 1997 Resolved
PROVIDE NAVAL ARCHITECTS EVALUATION OF FISH TANK AND PALM TREE INSTALLATIONON VESSELS STABILITY OR CONDUCT SIMPLIFIED STABILITY TEST._x001C_
Condition: Unknown
Due 11 August 1997
Resolved 18 February 1998
Lifesaving
Issued 25 July 1997 Resolved
PASSENGER CAPACITY REDUCED TO 141 PENDING REPLACEMENT OF FOUR PFD'S.
Condition: Unknown
Due 11 August 1997
Resolved 18 February 1998
Engineering
Issued 25 July 1997 Resolved
INSTALL 30X30 FLAME SCREEN IN F/O VENTS.
Condition: Unknown
Due 11 August 1997
Resolved 18 February 1998
Lifesaving
Issued 25 July 1997 Resolved
REPLACE WATERLIGHT BATTERY.
Condition: Unknown
Due 11 August 1997
Resolved 18 February 1998
Lifesaving
Issued 25 July 1997 Resolved
INSTALL REFLECTIVE MATERIAL ON LIFERING.
Condition: Unknown
Due 18 February 1998
Resolved 18 February 1998
Electrical
Issued 12 July 1996 Resolved
INSTALL GLOBE COVERS WHERE MISSING THROUGHOUT THE VESSEL.
Condition: Unknown
Due 19 July 1996
Resolved 6 September 1996
Documentation
Issued 12 July 1996 Resolved
[withheld — contains personal information; the deficiency system, dates, and resolution status are shown above]
Condition: Unknown
Due 19 July 1996
Resolved 6 September 1996
Accommodation/Occupational Safety
Issued 12 July 1996 Resolved
INSTALL BUNTING, CHAIN LINK FENCE, WIRE MESH OR SIMILAR MATERIAL ON AFT MAIN DECK PASSENGER RAILS, BELOW TOP RAIL COURSE.
Condition: Unknown
Due 12 August 1996
Resolved 6 September 1996
Lifesaving
Issued 12 July 1996 Resolved
REPLACE 60' LINE ON RING BUOY.
Condition: Unknown
Due 19 July 1996
Resolved 6 September 1996
Lifesaving
Issued 12 July 1996 Resolved
PROVIDE 13 ADULT LIFE PRESERVERS, TOTAL PERSONS ALLOWED ON BOARD SHALL NOT EXCEED 136 UNTIL ADDITIONAL LIFE PRESERVERS ARE PROVIDED.
Condition: Unknown
Due 12 August 1996
Resolved 6 September 1996
Lifesaving
Issued 12 July 1996 Resolved
PAINT FLARE CONTAINER ORANGE AND STENCIL WITH "DISTRESS SIGNALS".
Condition: Unknown
Due 19 July 1996
Resolved 6 September 1996
Engineering
Issued 7 August 1995 Resolved
Relabel emergency fuel shutt off valves.
Condition: Unknown
Due 27 September 1995
Resolved 27 September 1995
Lifesaving
Issued 7 August 1995 Resolved
Provide 3 additional orange smoke signals.
Condition: Unknown
Due 27 September 1995
Resolved 27 September 1995
Navigation
Issued 7 August 1995 Resolved
Secure starboard navigation light.
Condition: Unknown
Due 27 September 1995
Resolved 27 September 1995
Documentation
Issued 9 September 1994 Resolved
Provide proof of drug testing for all employees.
Condition: Unknown
Due 9 September 1994
Resolved 9 September 1994
Electrical
Issued 9 September 1994 Resolved
Install cover on junction box starboard side of wheelhouse, properly install wiring with mechanical connections.
Condition: Unknown
Due 9 September 1994
Resolved 9 September 1994
Lifesaving
Issued 9 September 1994 Resolved
Provide onboard 2 additional adult PFD's (lifejackets) and 2 additional child size PFD's. Vessels total number of passengers is reduced to 147 total including not more than 13 children until additional PFD's are onboard.
Condition: Unknown
Due 9 September 1994
Resolved 9 September 1994
Lifesaving
Issued 9 September 1994 Resolved
Provide line for ring buoy waterlight and mount light near ring buoy.
Condition: Unknown
Due 9 September 1994
Resolved 14 September 1994
Construction/Loadline
Issued 31 August 1994 Resolved
Double clamp overboard discharge starboard side third hold.
Condition: Unknown
Due 31 August 1994
Resolved 31 August 1994
Construction/Loadline
Issued 31 August 1994 Resolved
Label manifold valves for bilge suction & permanently mount in engineroom.
Condition: Unknown
Due 31 August 1994
Resolved 31 August 1994
Construction/Loadline
Issued 31 August 1994 Resolved
Double clamp all overboard discharge hoses in engineroom.
Condition: Unknown
Due 31 August 1994
Resolved 31 August 1994
Documentation
Issued 31 August 1994 Resolved
Provide radiotelephone certificate on board, vessel limited to not more than 1000 feet from land until complete.
Condition: Unknown
Due 31 August 1994
Resolved 31 August 1994
Construction/Loadline
Issued 31 August 1994 Resolved
Prove operation of reach rod for forepeak.
Condition: Unknown
Due 31 August 1994
Resolved 31 August 1994
Accommodation/Occupational Safety
Issued 31 August 1994 Resolved
Make permanent repair to pump out line for sewage tank.
Condition: Unknown
Due 31 August 1994
Resolved 31 August 1994
Engineering
Issued 14 July 1993 Resolved
Open air reciever for internal exam not later than next drydock.
Condition: Unknown
Due 14 July 1993
Resolved 14 July 1993
Navigation
Issued 17 September 1992 Resolved
Permanently mount/install air receiver & compressor located under bridge deck. Prove ASME approval.
Condition: Unknown
Due 17 September 1992
Resolved 17 September 1992
Construction/Loadline
Issued 17 September 1992 Resolved
Remove oil & residue from bilges.
Condition: Unknown
Due 17 September 1992
Resolved 17 September 1992
Lifesaving
Issued 22 July 1991 Resolved
REPAIR WATERLIGHT FOR RINGBUOY PRIOR TO OPERATING PAST SUSNSET AND NO LATERTHAN 01AUG91.
Condition: Unknown
Due 22 July 1991
Resolved 22 July 1991
Documentation
Issued 22 July 1991 Resolved
RENEW FCC STATION LICENSE PRIOR TO OPERATING MORE THAN 1000 FEET FROM LAND.
Condition: Unknown
Due 22 July 1991
Resolved 22 July 1991
Electrical
Issued 16 July 1990 Resolved
REPLACE WIRING, 2ND DECK OVERHEAD LIGHT STRING.
Condition: Unknown
Due 16 July 1990
Resolved 16 July 1990
Electrical
Issued 16 July 1990 Resolved
REPAIR GEN FREQ METER.
Condition: Unknown
Due 16 July 1990
Resolved 16 July 1990
Lifesaving
Issued 16 July 1990 Resolved
REPAIR RINGBUOY WATER LIGHT.
Condition: Unknown
Due 16 July 1990
Resolved 16 July 1990
Accommodation/Occupational Safety
Issued 16 July 1990 Resolved
REPAIR A/C OUTLET COVER (WATERTIGHT) AFT SIDE WHEELHOUSE ROOF EXTERIOR.
Condition: Unknown
Due 16 July 1990
Resolved 16 July 1990
Electrical
Issued 16 July 1990 Resolved
INSTALL A STERNLIGHT IAW 72 COLREGS.
Condition: Unknown
Due 16 July 1990
Resolved 16 July 1990
Electrical
Issued 16 July 1990 Resolved
REPLACE HOT DOG STEAMER CORD.
Condition: Unknown
Due 16 July 1990
Resolved 16 July 1990
Navigation
Issued 4 December 1989 Resolved
REPOSITION MASTHEAD/SIDE LIGHTS TO COMPLY WITH NAVIGATION RULES. (RULE 84.03(G)).
Condition: Unknown
Due 4 December 1989
Resolved 4 December 1989
Electrical
Issued 2 October 1989 Resolved
PROVIDE A RELIEF VALVE WITH HAND RELIEF DEVICE ON AIR RECEIVER.
Condition: Unknown
Due 2 October 1989
Resolved 2 October 1989
Electrical
Issued 2 October 1989 Resolved
REPAIR ELECTRICAL GENERATOR (PORT).
Condition: Unknown
Due 2 October 1989
Resolved 2 October 1989
Construction/Loadline
Issued 2 October 1989 Resolved
PROVIDE SUFFICIENT HOSES FOR THE PORTABLE BILGE PUMP.
Condition: Unknown
Due 2 October 1989
Resolved 2 October 1989
Navigation
Issued 2 October 1989 Resolved
REPOSITION MASTHEAD/SIDE LIGHTS TO COMPLY WITH NAVIGATION RULES. (RULE 84.03(G)).
Condition: Unknown
Due 2 October 1989
Resolved 2 October 1989
Electrical
Issued 2 October 1989 Resolved
REPLACE BROKEN HOSE CLAMP AND STOP LEAK - PORT MAIN ENGINE O/B DISCHARGE AT THE SHELL.
Condition: Unknown
Due 2 October 1989
Resolved 2 October 1989
Deck/Cargo
Issued 2 October 1989 Resolved
CLEAN ALL OIL FROM LAZARETTE.
Condition: Unknown
Due 2 October 1989
Resolved 2 October 1989
Documentation
Issued 15 August 1989 Resolved
DRYDOCK DUE 15FEB91. CONTACT USCG PRIOR TO THIS DATE TO SCHEDULE THIS INSPECTION.
Condition: Unknown
Due 15 August 1989
Resolved 15 August 1989
Electrical
Issued 19 September 1988 Resolved
MOUNT ICE MACHINE CIRCULATION MOTOR & PROVIDE FIXED APPROVED WIRE THROUGH CIRCUIT BOX.
Condition: Unknown
Due 19 September 1988
Resolved 19 September 1988
Electrical
Issued 19 September 1988 Resolved
PROVIDE 2 HOSE CLAMPS FOR STARBOARD ENGINE EXHAUST SYSTEM.
Condition: Unknown
Due 19 September 1988
Resolved 19 September 1988
Electrical
Issued 19 September 1988 Resolved
REMOVE OPEN WIRE SYSTEM ON STARBOARD SIDE(BROWN) OR DEAD END IN JUNCTION BOX.
Condition: Unknown
Due 19 September 1988
Resolved 19 September 1988
Electrical
Issued 19 September 1988 Resolved
PROVIDE SKETCH OF ELECTRICAL WIRING & EXHAUST SYSTEM FOR NEWLY INSTALLED BACK-UP GENERATOR.
Condition: Unknown
Due 19 September 1988
Resolved 19 September 1988
Deck/Cargo
Issued 19 September 1988 Resolved
MAKE PERMANENT REPAIRS TO THE FIRE & BILGE PUMP PRIOR TO CARRYING PASSENGERS.
Condition: Unknown
Due 19 September 1988
Resolved 19 September 1988
Documentation
Issued 19 September 1988 Resolved
PROVIDE NEW FCC SAFETY CERTIFICATE.
Condition: Unknown
Due 19 September 1988
Resolved 19 September 1988
Electrical
Issued 19 September 1988 Resolved
PROVIDE NEW STARBOARD ENGINE BATTERY IWO CRACKED BATTERY.
Condition: Unknown
Due 19 September 1988
Resolved 19 September 1988
Lifesaving
Issued 19 September 1988 Resolved
PROVIDE 31 APPROVED ADULT LIFEJACKETS, UNTIL THEY ARE POVIDED, THE NUMBER OF PERSONS IS REDUCED TO 118.
Condition: Unknown
Due 19 September 1988
Resolved 19 September 1988
Electrical
Issued 8 June 1987 Resolved
PROVIDE BATTERY BOX AND COVER FOR GENERATOR START BATTERY.
Condition: Unknown
Due 8 June 1987
Resolved 8 June 1987
Electrical
Issued 8 June 1987 Resolved
PROPERLY SECURE MUFFLER FOR GENERATOR.
Condition: Unknown
Due 8 June 1987
Resolved 8 June 1987

Casualty record · 1

27 January 2007Routine · role: Involved in a Marine Casualty · activity 3049843
Each line is an incident investigation the Coast Guard recorded with this hull among the vessels involved, with the date and the classification the Coast Guard gave it, and the bridge, lock or dam the investigation names where it names one. Involvement is not fault. The investigation narrative is not published. Source: IIR, through 2026.

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.