27 August 2025
Administrative Inspection · Deficiency Check · Annual Inspection · Internal Structural Exam
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 8219332
6 August 2025
Drydock Exam · Internal Structural Exam · Deficiency Check · Hull Examination
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 8170911
2 October 2024
Annual Inspection
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 8004774
14 December 2023
In-Service Inspection
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 7807616
4 October 2023
Annual Inspection · Deficiency Check
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 7796668
16 August 2023
Internal Structural Exam · Examination of Repairs · Hull Examination
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 7725893
10 May 2023
In-Service Inspection
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 7668526
19 October 2022
Deficiency Check · Annual Inspection
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 7562321
25 August 2021
Deficiency Check · Hull Examination · COI Inspection · DAPI Audit · Internal Structural Exam · Administrative Inspection
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 7241640
1 July 2021
Administrative Inspection
Administrative · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 7241683
6 August 2020
Annual Inspection · DAPI Audit
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 7014867
13 November 2019
Administrative Inspection · Annual Inspection · DAPI Audit · Deficiency Check
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 6839618
5 September 2019
Examination of Repairs · Internal Structural Exam · Drydock Exam
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 6747446
13 September 2018
DAPI Audit · Deficiency Check · Administrative Inspection · Examination of Repairs · Annual Inspection
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 6517968
19 September 2017
Internal Structural Exam · Hull Examination
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 6266383
18 August 2017
DAPI Audit · Annual Inspection
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 6211964
5 September 2016
COI Inspection
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 5979526
10 - Safety of Navigation › N/A - No Subsystem › Lights, shapes, sound-signals
Issued 18 November 2025
Resolved
All vessels must have navigation lights that are in compliance with the applicable sections of the International and Inland Navigation Rules. Starboard sidelight was non-operational. Replace sidelight to the satisfaction of the attending MI prior to carriage of passengers.
46 CFR 183.420
Action required: 701 - Prior to carriage of passengers/cargo
Due 18 November 2025
Resolved 10 December 2025
Resolution: Starboard sidelight has been repaired and was verified by MI.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 2 October 2024
Resolved
46 CFR 180.71 (a)
An adult life jacket must be provided for each person carried on board a vessel. MI observed 23 adult size life jackets that needs to be replaced.
CODE 705: Vessel is restricted to carrying 126 people that would require and adult size life jacket.
Action required: 705 - Other - as specified
Due 2 October 2024
Resolved 1 November 2024
Resolution: Received pictures of new life jackets.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 2 October 2024
Resolved
46 CFR 185.604 (h)
Each life jacket must be marked with Type I retroreflective material. MI observed 13 adult sized life jackets that need new retroreflective material.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 16 October 2024
Resolved 1 November 2024
Resolution: Received pictures of life jackets with new retroreflective material.
01 - Certificates & Documentation › 011 - Ships Certificates › USCG Certificate of Documentation (COD)
Issued 4 October 2023
Resolved
Any vessel of at least five net tons which engages in coastwise trade on the navigable waters of the United States must have a Certificate of Documentation onboard.
COD expired.
46 CFR 67.7
Action required: 701 - Prior to carriage of passengers/cargo
Due 4 October 2023
Resolved 4 October 2023
Resolution: Received proof that COD renewal was paid for.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 4 October 2023
Resolved
An adult life jacket must be provided for each person carried onboard.
Vessel missing 6 adult life jackets; max persons allowed reduced to 143.
46 CFR 180.71(a)
Action required: 705 - Other - as specified
Due 4 October 2023
Resolved 9 October 2023
Resolution: 6 additional adult life jackets provided.
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 4 October 2023
Resolved
Portable fire extinguishers shall be installed and located to the satisfaction of the Officer in Charge, Marine Inspection.
CO2 fire extinguisher in the main accommodation space is not mounted.
46 CFR 181.30-10(b)
Action required: 16 - Rectify deficiencies w/in 14 days
Due 18 October 2023
Resolved 9 October 2023
Resolution: Extinguisher mounted.
08 - Alarms › N/A - No Subsystem › Other (alarms)
Issued 4 October 2023
Resolved
A visual and audible alarm must be provided at the operating station to indicate a high water level in a space with a through-hull fitting below the deepest load waterline.
Forward AC space bilge high water alarm inoperative.
46 CFR 182.530(a)
Action required: 16 - Rectify deficiencies w/in 14 days
Due 18 October 2023
Resolved 4 October 2023
Resolution: Alarm repaired by the end of inspection.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 19 October 2022
Resolved
An adult life jacket must be provided for each person carried on board a vessel. OCMI counted 26 life jackets that could no longer meet the requirements to be in service.
Vessel is restricted to carrying 123 passengers including crew until in full compliance with the amount required on vessels COI.
46 CFR 180.71(a)
Action required: 16 - Rectify deficiencies w/in 14 days
Due 2 November 2022
Resolved 17 November 2022
Resolution: Vessel has purchased 26 new lifejackets and put them into service.
02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 19 October 2022
Resolved
The number of penetrations in a watertight bulkhead must be minimized. A penetration in a watertight bulkhead must be as high and as far inboard in the bulkhead as practicable, and made watertight.
OCMI found the cable runs did not have sufficient amount of packing to make a quality seal.
46 CFR 179.320(c)
Action required: 16 - Rectify deficiencies w/in 14 days
Due 2 November 2022
Resolved 28 October 2022
Resolution: Pictures rectifying deficiency sent.
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 19 October 2022
Resolved
Portable fire extinguishers shall be installed and located to the satisfaction of the Officer in Charge, Marine Inspection.
OCMI found fire extinguisher in the engine room to be mounted in a bracket that was not safely secured.
46 CFR 181.30-10(B)
Action required: 16 - Rectify deficiencies w/in 14 days
Due 2 November 2022
Resolved 28 October 2022
Resolution: Pictures rectifying deficiency sent.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Operation of machinery
Issued 25 August 2021
Resolved
A limit switch to stop the steering gear before it reaches the rudder stops required by paragraph (e) of this section.
During operational testing of the steering system, whenever steering gear was pressed hard STBD, the port tiller arm was contacting the rudder stop and the rudder stop would deflect back. At the next DD, disassemble rudder and associated pins and bolts to determine any damage caused buy this as well as inspect all welds and potential structural areas that may have been affecting by the flexing of the rudder stop. Additionally provide proposal to correct the tiller from impacting the rudder stop.
46CFR 182.610(e)(5)
Action required: 705 - Other - as specified
Due 25 August 2021
Resolved 2 October 2021
Resolution: Rudder tube inserts and posts installed, all sat.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 25 August 2021
Resolved
Each life jacket must be marked with Type I retroflection tape material.
During the life jacket inspection there was 7 life jackets identified where the retro reflective tape was serviceable. Passenger count is limited to 138 until tape or jackets are replaced.
46 CFR 185.604(h)
Action required: 50 - Rectify deficiencies w/in 30 days
Due 25 September 2021
Resolved 24 September 2021
Resolution: Life jackets had retro reflective tape replaced.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 13 November 2019
Resolved
An adult life jacket must be provided for each person carried on board a vessel. 12 life jackets were found to be unserviceable and were destroyed in the presence of MI. 141 servicable life jackets (adult) and > 15 child life jackets remain. Vsl restricted to 137 passengers with manning remaining the same.
46 CFR 180.71
Action required: 16 - Rectify deficiencies w/in 14 days
Due 27 November 2019
Resolved 19 November 2019
Resolution: 12 life jackets were replaced, labeled, and properly stowed.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 13 November 2019
Resolved
All vessels shall be provided with a satisfactory arrangement for draining any watertight compartment other than small buoyancy compartments. The fixed bilge pump and piping system was not operational during this inspection. Vsl was unable to dewater forepeak or lazarette . Additionally during test of bilge piping in lazarette the bilge pipe broke, rendering it inoperable.
46 CFR 182.25-1(a)
Action required: 701 - Prior to carriage of passengers/cargo
Due 13 November 2019
Resolved 19 November 2019
Resolution: Bilge pump check valves were replaced in the forepeak and lazarette. Piping was replaced as original in lazarette. Full system was tested with no issues.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 13 November 2019
Resolved
Each ring life buoy on a vessel must be approved in accordance with 160.050 in subchapter Q. The grabline shall be 3/8 inch diameter polyethyline, polypropyline, or other suitable bouyant type. The grab lines on both life rings were deteriorated. Replace.
46 CFR 180.70(b)(1)
Action required: 16 - Rectify deficiencies w/in 14 days
Due 27 November 2019
Resolved 2 December 2019
Resolution: Grab lines replaced as original.
11 - Life Saving Appliances › N/A - No Subsystem › Rescue boats
Issued 13 November 2019
Resolved
The vessel must be sufficiently maneuverable, arranged, and equipped to allow the crew to recover a helpless person from the water. During man overboard drill, a crew member fell overboard. Crew was unable to demonstrate recovery of helpless person. Propose plan and demonstrate prior to carrying passengers.
46 CFR 180.210
Action required: 701 - Prior to carriage of passengers/cargo
Due 13 November 2019
Resolved 19 November 2019
Resolution: Rescue ladder inspected for workmanship, all sat. While underway, witnessed man overboard drill with 2 crewmembers and captain conning the vessel.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 13 November 2019
Resolved
Electrical installations shall be reasonably safe from electrical shock of personnel. Exposed wires found on top deck, port side lighting box. Repair.
46 CFR 183.01-5
Action required: 16 - Rectify deficiencies w/in 14 days
Due 27 November 2019
Resolved 19 November 2019
Resolution: Lighting box with exposed wires was replaced.
02 - Structural Conditions › N/A - No Subsystem › Beams, frames, floors-corrosion
Issued 13 November 2019
Resolved
Scantlings, material, fastenings, workmanship, and arrangements of vessel shall be such as to provide for safe operation. Center stantion in forepeak has a broken weld at bottom connection to the hull. Repair.
46 CFR 177.01-5
Action required: 16 - Rectify deficiencies w/in 14 days
Due 27 November 2019
Resolved 2 December 2019
Resolution: Broken weld was grinded out and welded to the satisfaction of the MI.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 13 September 2018
Resolved
Where flexible nonmetallic hose is permitted for use in piping systems by this section, it must meet SAE Standard J–1942, ‘‘Hose and Hose Assemblies for Marine Applications,’’ or be specifically approved by the Commandant.
Flexible hose installed on starboard side bilge piping forward of starboard main engine. Provide repair proposal. - 46CFR182.720(e)
Action required: 16 - Rectify deficiencies w/in 14 days
Due 27 September 2018
Resolved 3 October 2018
Resolution: Operator replaced flex hose with approved type.
02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 13 September 2018
Resolved
Vessels shall be inspected for compliance with the standards required by this subchapter. For items not covered by standards in this subchapter, inspection shall be in accordance with standards acceptable to the OCMI, as good marine practice. 46CFR176.25-1(a)
Discovered hole in top of sewage tank. Repair. - 46CFR178.25-1(a)
Action required: 16 - Rectify deficiencies w/in 14 days
Due 27 September 2018
Resolved 3 October 2018
Resolution: Verified weld repairs to top of tank.
Engineering › Steering Gear System › Pin
Issued 6 September 2016
Resolved
Replace cotter pin on port rudder stock. Cotter pin missing IAW 46 CFR 182.30-1
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 6 September 2016
Fire Fighting › Remote Fuel Shutoff › General
Issued 6 September 2016
Resolved
Lable location of emergency fuel shut off and direction of turn. Make operable from outside machinery space IAW 46 cfr 185.608
Action required: 705 - Other - as specified
Due 20 September 2016
Resolved 16 September 2016