Records from 1984 to 1988. Most recent: inspection, 9 December 1988.
A report is not offered for this hull: Its record holds only 2 of the seven kinds of material a report is built from: inspections, deficiencies, operational controls, tow-unit appearances, casualty records, dimensions and documentation. That is a statement about the record, not about the vessel. Reports.
Lifesaving
Issued 6 September 1988
Resolved
REPAIR INOPERATIVE GENERAL ALARM BELL IN PORT PUMP ROOM LOWER.
Condition: Unknown
Due 6 September 1988
Resolved 6 September 1988
Construction/Loadline
Issued 6 September 1988
Resolved
REPAIR CLOGGED SOUNDING TUBES ON THE FOLLOWING TANKS: A902B, A908B, A918B,A902B, B906B, B914B(PORT), A901B, A903B, A905B, A907B, A909B, A913B(STBD), A919EO, B907B, B911B, B911B, B915B. CURRENTLY CONTROL RM READS ALL ABOVE FULL REGARDLESS OF STATE.
Condition: Unknown
Due 30 November 1988
Resolved 18 May 2002
Resolution: MISLE Maintenance - Resolved all open deficiencies issued prior to 6/1/1997 where activity was closed and deficiency due date was past
Fire Fighting
Issued 6 September 1988
Resolved
REPAIR WASTED FIRE EXTINGUISHER BRACKET ON FIRE STATION #57 STBD.
Condition: Unknown
Due 6 September 1988
Resolved 6 September 1988
Construction/Loadline
Issued 6 September 1988
Resolved
REPAIR REMOTE CONTROL ON A918B. CURRENTLY INOPERATIVE.
Condition: Unknown
Due 6 September 1988
Resolved 6 September 1988
Construction/Loadline
Issued 6 September 1988
Resolved
CONDUCT SPECIAL EXAM IN LIEU OF DRYDOCKING AT LIGHT DRAFT PRIOR TO CONDUCTING DRILLING OPERATIONS.
Condition: Unknown
Due 31 October 1988
Resolved 18 May 2002
Resolution: MISLE Maintenance - Resolved all open deficiencies issued prior to 6/1/1997 where activity was closed and deficiency due date was past
Construction/Loadline
Issued 6 September 1988
Resolved
BELT GUAGE ALL BALLAST AND FUEL TANKS.
Condition: Unknown
Due 15 November 1988
Resolved 18 May 2002
Resolution: MISLE Maintenance - Resolved all open deficiencies issued prior to 6/1/1997 where activity was closed and deficiency due date was past
Construction/Loadline
Issued 6 September 1988
Resolved
GUAGE WIND AND WATER AREAS AT LIGHT DRAFT, SURVIVAL DRAFT AND NORMAL OPERATING DRAFT.
Condition: Unknown
Due 15 November 1988
Resolved 18 May 2002
Resolution: MISLE Maintenance - Resolved all open deficiencies issued prior to 6/1/1997 where activity was closed and deficiency due date was past
Construction/Loadline
Issued 6 September 1988
Resolved
MAKE ALL INTEGRAL TANKS, VOIDS AND COMPARTMENTS IN SPONSONS AVAILABLE FOR INSPECTION BY A COAST GUARD INSPECTOR.
Condition: Unknown
Due 15 November 1988
Resolved 18 May 2002
Resolution: MISLE Maintenance - Resolved all open deficiencies issued prior to 6/1/1997 where activity was closed and deficiency due date was past
Electrical
Issued 6 September 1988
Resolved
REPLACE THE 408V POWER PANEL COVER AND REMOVE THE JURY RIGGED POWER PLUG RECEPTACLE FROM THE INTERIOR OF THE CONTROL BOX LOCATED IN THE EMERGENCY GENERATOR ROOM.
Condition: Unknown
Due 6 September 1988
Resolved 6 September 1988
Electrical
Issued 6 September 1988
Resolved
INSTALL A BLANK IN THE EMERGENCY [name withheld] IN THE EMERGENCY GENERATOR ROOM.
Condition: Unknown
Due 6 September 1988
Resolved 6 September 1988
Electrical
Issued 6 September 1988
Resolved
REPAIR THE LAGGING ON THE EMERGENCY GENERATOR LEFT SIDE LOOKING FORWARD TOWARDS RADIATOR. IF MATERIAL HAS ASBESTOS, REMOVE AND REPLACE WITH NON ASBESTOS TYPE.
Condition: Unknown
Due 30 November 1988
Resolved 18 May 2002
Resolution: MISLE Maintenance - Resolved all open deficiencies issued prior to 6/1/1997 where activity was closed and deficiency due date was past
Construction/Loadline
Issued 6 September 1988
Resolved
REPAIR THE WARPED HATCH COVER AND REPLACE DOGS AS NECESSARY. WATER TEST WITH HOSE TO ENSURE IT IS WATERTIGHT. HATCH LOCATED OUTSIDE EMERGENCY GENERATOR ROOM.
Condition: Unknown
Due 6 September 1988
Resolved 6 September 1988
Construction/Loadline
Issued 6 September 1988
Resolved
REPLACE DOGS ON THE WATERTIGHT HATCH (MAIN DECK) STBD SIDE FORWARD OF THE CRANE.
Condition: Unknown
Due 6 September 1988
Resolved 6 September 1988
Fire Fighting
Issued 6 September 1988
Resolved
REPLACE THE RECALLED HOSE ON THE B-V FIRE EXTINGUISHER ON THE HELO DECK.
Condition: Unknown
Due 6 September 1988
Resolved 6 September 1988
Unknown
Issued 6 September 1988
Resolved
PROVIDE SCATLING DRAWINGS OF THE HP TENSIONEN BOTTLE. HEAVY PITTING NOTED ON MANY OF THE BOTTLES LOCATED IN THE HORIZOTIAL RACK AT THE HELO DECK. SOME PITTS APPEAR TO BE 1/8"-3/16" DEEP (BOTTLE 72-238-27).
Condition: Unknown
Due 6 October 1988
Resolved 18 May 2002
Resolution: MISLE Maintenance - Resolved all open deficiencies issued prior to 6/1/1997 where activity was closed and deficiency due date was past
Construction/Loadline
Issued 6 September 1988
Resolved
REPLACE THE BALLAST VALVE AT B-907-B.
Condition: Unknown
Due 6 September 1988
Resolved 6 September 1988
Lifesaving
Issued 6 September 1988
Resolved
REPAIR OR REPLACE LIGHT ON LIFERING LOCATED BY PORT CRANE.
Condition: Unknown
Due 6 September 1988
Resolved 6 September 1988
Construction/Loadline
Issued 6 September 1988
Resolved
INSTALL NON-SKID SURFACE FOR HELO DECK PERSONNEL SAFETY INVOLVED.
Condition: Unknown
Due 6 September 1988
Resolved 6 September 1988
Electrical
Issued 3 June 1988
Resolved
PROVIDE GLOBES AND GUARDS FOR THE EXISTING OUTLETS IN ALL VERTICAL COLUMNS.
Condition: Unknown
Due 3 June 1988
Resolved 3 June 1988
Navigation
Issued 3 June 1988
Resolved
PROVIDE PERIMETER MARKINGS ON THE HELO DECK.
Condition: Unknown
Due 3 June 1988
Resolved 3 June 1988
Construction/Loadline
Issued 3 June 1988
Resolved
REPAIR OR REPLACE INOPERATIVE ELECTRIC (LIMIT TORQUE) VALVES: PORT PUMP ROOM: A 908-B, A 912-B(SUCTION), B 912-B(SUCTION), B 914-B(DISCH.) STBD PUMP RM: B 907-B(SUCTION)
Condition: Unknown
Due 3 June 1988
Resolved 3 June 1988
Fire Fighting
Issued 3 June 1988
Resolved
REPAIR FIRE STATION #23, VALVE IS FROZEN SHUT, LOCATED IN PORT PUMP ROOM. REMOVE 10-12" OF DIESEL FUEL FROM THE BILGE IN THE PORT PUMP ROOM.
Condition: Unknown
Due 3 June 1988
Resolved 3 June 1988
Construction/Loadline
Issued 3 June 1988
Resolved
REMOVE ALL STANDING WATER FROM THE VOID SPACES IN THE BOX GIRDER, LOCATE SOURCE OF WATER AND REPAIR.
Condition: Unknown
Due 3 June 1988
Resolved 3 June 1988
Construction/Loadline
Issued 3 June 1988
Resolved
COMPLETE INTERNAL INSPECTION OF THE STARBOARD BOW VERTICAL COLUMNS OPEN VOID COVERS TO THE COLUMN VOIDS.
Condition: Unknown
Due 3 June 1988
Resolved 3 June 1988
Construction/Loadline
Issued 3 June 1988
Resolved
REPAIR OR REPLACE INOPERATIVE SEACHEST VALVES (12" BALLAST SUCTION AND 12" ENGINE COOLING) IN THE PORT PUMP ROOM - (MANUAL VALVES).
Condition: Unknown
Due 3 June 1988
Resolved 3 June 1988
Construction/Loadline
Issued 3 June 1988
Resolved
COMPLETE UNDERWATER PORTION OF DRYDOCK, ENTER BALLAST TANKS, UNDERWATER VIDEO OF HULL.
Condition: Unknown
Due 3 June 1988
Resolved 3 June 1988
Accommodation/Occupational Safety
Issued 30 November 1987
Resolved
PROVIDE THE FOLLOWING FIRST AID SUPPLIES: (A) 12 AMMONIA AMPULES OR EQUAL, (B) 2 LEG SPLINTS, (C) ONE FOLLIE. (46 CFR 108.707)
Condition: Unknown
Due 30 November 1987
Resolved 30 November 1987
Lifesaving
Issued 30 November 1987
Resolved
REPLACE PRESSURE GAUGE ON AIR BOTTLE IN NO. 1 LIFEBOAT. ALSO REPAIR BROKENLIFELINE ON STARBOARD SIDE OF BOAT. (46 CFR 160.035)
Condition: Unknown
Due 30 November 1987
Resolved 30 November 1987
Electrical
Issued 30 November 1987
Resolved
FILL EYS FITTING ON LIGHT IN PAINT LOCKER. (46 CFR 111.105-15)
Condition: Unknown
Due 30 November 1987
Resolved 30 November 1987
Engineering
Issued 30 November 1987
Resolved
PROVIDE MAXIMUM ALLOWANCE WORKING PRESSURE FOR ALL AIR PRESSURE VESSELS (46 CFR 54)
Condition: Unknown
Due 30 November 1987
Resolved 30 November 1987
Engineering
Issued 30 November 1987
Resolved
TEST ALL RELIEF VALVES FOR ALL 4 PRESSURE VESSELS AFTER ESTABLISHING THE MAXIMUM ALLOWABLE WORKING PRESSURE. (46 CFR 61.10-5)
Condition: Unknown
Due 30 November 1987
Resolved 30 November 1987
Documentation
Issued 30 November 1987
Resolved
ALL STATION BILLS TO BE SIGNED BY PERSON IN CHARGE. (46 CFR 109.505)
Condition: Unknown
Due 30 November 1987
Resolved 30 November 1987
Lifesaving
Issued 30 November 1987
Resolved
REPAIR OR REPLACE THE FOLLOWING ITEMS IN NO.2 (PORT) LIFEBOAT: (A) INSTALLAPPROPRIATE BRACKET FOR FORWARD FIRE EXTINGUISHER, (B) REPLACE ALL WATER OVER 5 YEARS OLD, (C) INSTALL VIBRATION RESISTANT NUT ON RUDDER TILLER ARM ENSURE THAT RUDDER PROPERLY ALIGNED WIRTH TILLER ARM. (46 CFR 160.035)
Condition: Unknown
Due 30 November 1987
Resolved 30 November 1987
Electrical
Issued 14 December 1986
Resolved
TEST THE TEMPORARY GENERATOR; HIGH WATER JACKET, LOW LUBE OIL AND OVERSPEEDTRIP.
Condition: Unknown
Due 14 December 1986
Resolved 14 December 1986
Fire Fighting
Issued 14 December 1986
Resolved
REPLACE FIXED CO2 BOTTLE FOR PAINT LOCKER THAT WAS SEND IN FOR SERVICING.
Condition: Unknown
Due 14 December 1986
Resolved 14 December 1986
Accommodation/Occupational Safety
Issued 14 December 1986
Resolved
REPAIR/REPLACE THE LOUVER FOR THE VENTILATIONS IN THE FOLLOWING QUARTERS, 18, 19, 24, 2, REPAIR THE CEILING IN ROOMS 22 AND 23, REPAIR THE CEILING INTHE QUARTERS PASSAGEWAYS.
Condition: Unknown
Due 14 December 1986
Resolved 14 December 1986
Lifesaving
Issued 14 December 1986
Resolved
MAKE AVAILABLE FOR INSPECTION ALL LIFEBOAT LIMIT SWITCHES, REPAIR OR REPLACE AS NECESSARY AND THE WINCH CONTROLLER AND MAIN DISCONNECT.
Condition: Unknown
Due 14 December 1986
Resolved 14 December 1986
Engineering
Issued 14 December 1986
Resolved
MAKE OPERABLE THE LOW LUBE OIL ENGINE SHUTDOWN ON NOS. 1 & 4 EMD.
Condition: Unknown
Due 14 December 1986
Resolved 14 December 1986
Accommodation/Occupational Safety
Issued 14 December 1986
Resolved
PROPERLY MAKE UP THE ELEVATOR HOIST CABLES (WIRE ROPE).
Condition: Unknown
Due 14 December 1986
Resolved 14 December 1986
Deck/Cargo
Issued 14 December 1986
Resolved
MAKE OPERABLE THE INDICATOR LIGHTS IN THE PORT CRANE; UPPER WHIP AND MAIN HOIST LIMIT AND BOOM SWING LOCK.
Condition: Unknown
Due 14 December 1986
Resolved 14 December 1986
Accommodation/Occupational Safety
Issued 14 December 1986
Resolved
REPAIR THE VERTICAL LADDER PERSONNEL GUARD ON BOTH BOW LEGS FROM MAIN DECK TO FIRST LANDING, OBSTRUCTION (BENT GUARD) IN WAY OF THE LADDER STBD STERN,CLEAR REPAIR HOLE IN DECK GRATING, HELO FUEL DECK, STBD SIDE.
Condition: Unknown
Due 14 December 1986
Resolved 14 December 1986
Fire Fighting
Issued 14 December 1986
Resolved
REPAIR THE GENERAL ALARM BELLS IN THE FOLLOWING LOCATIONS, HELO DECK - STBDAFT, THYRIG ROOM, PORT CRANE AND THE DRILL FLOOR (BELL ON DRILL FLOOR RINGSIN SHORT DURATIONS).
Condition: Unknown
Due 14 December 1986
Resolved 14 December 1986
Lifesaving
Issued 14 December 1986
Resolved
MANNING REDUCED TO 50 PERSONS. THIS REQUIREMENT IS DUE TO THE INFLATABLE LIFERAFT BEING BEYOND THEIR SERVICE DATE. SERVICING OF THE LIFERAFTS AND HYDROSTATIC RELEASES PENDS.
Condition: Unknown
Due 14 December 1986
Resolved 14 December 1986
Lifesaving
Issued 14 December 1986
Resolved
NO. 2 LIFEBOAT - PROVIDE ONE ADDITIONAL PAINTER AND HEAVING LINE, REFILL AIR BOTTLE.
Condition: Unknown
Due 14 December 1986
Resolved 14 December 1986
Lifesaving
Issued 14 December 1986
Resolved
NO.1 LIFEBOAT - PROVIDE WATER FOR 28 PERSONS, REFILL AIR BOTTLE PROVIDE DISCHARGE HOSE FOR THE BILGE PUMP, COMPASS (COMPASS +-60 DEGREES OUT FROM RIG COMPASS AND THE COMPASS IN THE #2 LIFEBOAT.
Condition: Unknown
Due 14 December 1986
Resolved 14 December 1986
Fire Fighting
Issued 14 December 1986
Resolved
MAKE OPERABLE THE FOAM PUMP(S) AND PROVIDE/FREE UP THE SWING & ELECTRONIC LOCKS ON THE FOAM TURRETS.
Condition: Unknown
Due 14 December 1986
Resolved 14 December 1986
Fire Fighting
Issued 14 December 1986
Resolved
UNPLUG FIRE STATION NOS. 1, 2, 10, 12, 13. FIRE MAIN PLUGGED WITH SEDIMENT. REPAIR/REPLACE HAND WHEEL ON FIRE STATION #17.
Condition: Unknown
Due 14 December 1986
Resolved 14 December 1986
Electrical
Issued 14 December 1986
Resolved
PROVIDE SECURE MOUNTINGS FOR THE MERCURY VAPOR LIGHTS AT THE ANCHOR WINDLASS.
Condition: Unknown
Due 14 December 1986
Resolved 14 December 1986
Construction/Loadline
Issued 14 December 1986
Resolved
REPAIR WASTED HATCH COAMING, MAIN DECK STARBOARD STERN, DOG HOUSE TO QUARTERS, REPAIR WASTED HAND RAIL, VERTICAL SUPPORT TO DECK CONNECTION, PORT STERN MAIN DECK.
Condition: Unknown
Due 14 December 1986
Resolved 14 December 1986
Accommodation/Occupational Safety
Issued 14 December 1986
Resolved
REPAIR WASTED DECK GRATING, MOON POOL AREA.
Condition: Unknown
Due 14 December 1986
Resolved 14 December 1986
Fire Fighting
Issued 14 December 1986
Resolved
REPLACE WASTED "RETURN ELL" ON FIRE STATION #16.
Condition: Unknown
Due 14 December 1986
Resolved 14 December 1986
Fire Fighting
Issued 14 December 1986
Resolved
CONDUCT HYDROSTATIC TEST OF THE BIV FIRE EXTINGUISHER PORT SIDE HELO DECK AND REFILL NITROGEN BOTTLE STBD SIDE HELO DECK.
Condition: Unknown
Due 14 December 1986
Resolved 14 December 1986
Navigation
Issued 14 December 1986
Resolved
PROVIDE OBSTRUCTION LIGHTS WITH THE PROPER FLASH, PROVIDE LENS FOR THE OBSTRUCTION LIGHT PORT BOW, LIGHT BURNING FIXED PORT STERN, RELAMP-REPAIR STBD BOW PORT & STERN LIGHTS.
Condition: Unknown
Due 14 December 1986
Resolved 14 December 1986
Navigation
Issued 14 December 1986
Resolved
MAKE OPERATIONAL THE NOT UNDER COMMAND LIGHTS, DERRICK.
Condition: Unknown
Due 14 December 1986
Resolved 14 December 1986
Navigation
Issued 14 December 1986
Resolved
MAKE OPERATIONAL THE ELECTRONIC FOG HORN, ARTIFICIAL ISLAND.
Condition: Unknown
Due 14 December 1986
Resolved 14 December 1986
Deck/Cargo
Issued 14 December 1986
Resolved
PROVIDE FLAME SCREEN FOR THE THRUSTER OIL STORAGE SERVICE TANKS.
Condition: Unknown
Due 14 December 1986
Resolved 14 December 1986
Construction/Loadline
Issued 14 December 1986
Resolved
PORT PUMP ROOM - REPAIR ELECTRICAL CABLE TO MOTORIZED VALUE #B-912 SUCTION,PROPERLY SUPPORT ELECTRICAL CABLES AND PROPERLY TERMINATE DEAD END WIRES, LOWER LEVEL.
Condition: Unknown
Due 14 December 1986
Resolved 14 December 1986
Engineering
Issued 14 December 1986
Resolved
REMOVE HOSE FROM THRUSTER COOLING SEA VALE IN THRUSTER ROOM #4.
Condition: Unknown
Due 14 December 1986
Resolved 14 December 1986
Engineering
Issued 14 December 1986
Resolved
PROVIDE GUARD FOR THE LUBE OIL STORAGE TANK SIGHT GLASS, EMD'S.
Condition: Unknown
Due 14 December 1986
Resolved 14 December 1986
Engineering
Issued 14 December 1986
Resolved
PROVIDE FOUR RELIEF VALVES FOR THE TENSIONER BOTTLES SET AT NOT MORE THAN 2400 PSI, AND ONE RELIEF VALVE SET AT NOT MORE THAN 150 PSI FOR THE DRILL FLOOR AIR RECEIVER.
Condition: Unknown
Due 14 December 1986
Resolved 14 December 1986
Electrical
Issued 14 December 1986
Resolved
PROVIDE LOSS OF VENTILATION ALARM FOR THE MUD PITS TO ALARM IN A NORMALLY MANNED AREA.
Condition: Unknown
Due 14 December 1986
Resolved 14 December 1986
Electrical
Issued 14 December 1986
Resolved
REMOVE PLASTIC TIE WRAPS ON ALL ELECTRICAL CABLE RUNS THAT ARE NOT SUPPORTED BY CABLE TRAYS OR RUN VERTICALLY.
Condition: Unknown
Due 14 December 1986
Resolved 14 December 1986
Deck/Cargo
Issued 14 December 1986
Resolved
TEST MUD PUMP RELIEF VALVES PRIOR TO COMMENCING DRILLING OPERATIONS.
Condition: Unknown
Due 14 December 1986
Resolved 14 December 1986
Engineering
Issued 20 February 1986
Resolved
PROVIDE NAMEPLATE DATA ON "RIG AIR" AIR RECEIVERS AND RELIEF VALVES WITHOUTNAMEPLATE DATA.
Condition: Unknown
Due 20 February 1986
Resolved 20 February 1986
Accommodation/Occupational Safety
Issued 20 February 1986
Resolved
REMOVE FIXED PIPING FRESH WATER CONNECTION TO KOOMEY UNIT.
Condition: Unknown
Due 20 February 1986
Resolved 20 February 1986
Deck/Cargo
Issued 20 February 1986
Resolved
REMOVE BRASS VALVE ON FUEL SEPERATOR/FILTER.
Condition: Unknown
Due 20 February 1986
Resolved 20 February 1986
Deck/Cargo
Issued 20 February 1986
Resolved
INSTALL HEAT RESISTANT SIGHT GLASS AND GUARDS ON FUEL TANKS IN CENTER STATEROOM, AND GENERATOR ROOM.
Condition: Unknown
Due 20 February 1986
Resolved 20 February 1986
Deck/Cargo
Issued 20 February 1986
Resolved
REPLACE/REPAIR OBSTRUCTION LIGHT BATTERIES.
Condition: Unknown
Due 20 February 1986
Resolved 20 February 1986
Deck/Cargo
Issued 20 February 1986
Resolved
REPAIR GENERAL ALARM BELL IN SHALE SHAKER HOUSE, STARBOARD CRANE PEDESTAL, AND AFT P-TANK ROOM.
Condition: Unknown
Due 20 February 1986
Resolved 20 February 1986
Construction/Loadline
Issued 20 February 1986
Resolved
MAKE THRUSTER HOUSINGS WATERTIGHT BY REINSTALLING WATERTIGHT DOORS OR SUBMIT CALCULATIONS THAT FLOODING OF ADJACENT SPACES DOES NOT AFFECT THE STABILITY OF THE RIG OR THE LOADLINE CERTIFICATE.
Condition: Unknown
Due 20 February 1986
Resolved 20 February 1986
Electrical
Issued 20 February 1986
Resolved
REMOVE TEMPORARY ELECTRICAL WIRE RUNS IN STARBOARD ELEVATOR SHAFT.
Condition: Unknown
Due 20 February 1986
Resolved 20 February 1986
Electrical
Issued 20 February 1986
Resolved
INSTALL GUARD ON UNIT IN MECHANIC'S SHOP.
Condition: Unknown
Due 20 February 1986
Resolved 20 February 1986
Deck/Cargo
Issued 20 February 1986
Resolved
INSTALL RELIEF VALVE WITH HAND RELIEVING GEAR ON AIR RECEIVER ABOVE MECHANIC'S SHOP.
Condition: Unknown
Due 20 February 1986
Resolved 20 February 1986
Deck/Cargo
Issued 20 February 1986
Resolved
INSTALL PROTECTIVE GUARD ON PORTABLE MUD CLEANING.
Condition: Unknown
Due 20 February 1986
Resolved 20 February 1986
Deck/Cargo
Issued 20 February 1986
Resolved
ADJUST WATERTIGHT DOORS TO MUD PUMROOM, SO THAT THE DOOR CLOSES PROPERLY.
Condition: Unknown
Due 20 February 1986
Resolved 20 February 1986
Deck/Cargo
Issued 20 February 1986
Resolved
PLACE PLUGS OR CAPS ON ALL GRAVITY DRAINS TO FUEL OIL AND LUBE OIL TANKS INGENERATOR ROOM AND MUDPUMP ROOM.
Condition: Unknown
Due 20 February 1986
Resolved 20 February 1986
Deck/Cargo
Issued 20 February 1986
Resolved
INSTALL FLAMESCREEN VENT ON LUBE OIL TANKS IN AUXILIARY MACHINERY SPACE.
Condition: Unknown
Due 20 February 1986
Resolved 20 February 1986
Lifesaving
Issued 20 February 1986
Resolved
REPAIR INOPERATIVE LIMIT SWITCH, STERN #1 LIFEBOAT.
Condition: Unknown
Due 20 February 1986
Resolved 20 February 1986
Lifesaving
Issued 20 February 1986
Resolved
REPAIR DOOR AND HATCH #1 LIFE BOAT AFTER STARBOARD SIDE.
Condition: Unknown
Due 20 February 1986
Resolved 20 February 1986
Fire Fighting
Issued 20 February 1986
Resolved
REPAIR IN-OPERATIVE GENERAL ALARM BELL ON HELO DECK NEXT TO AIRCRAFT FUEL TANK.
Condition: Unknown
Due 20 February 1986
Resolved 20 February 1986
Fire Fighting
Issued 20 February 1986
Resolved
REPAIR GASKET ON SACK ROOM HATCH MAIN DECK.
Condition: Unknown
Due 20 February 1986
Resolved 20 February 1986
Deck/Cargo
Issued 20 February 1986
Resolved
PROVIDE FLAME SCREEN FOR AVIATION FUEL TANK AIR BLEEDER AND PROVIDE WATER TIGHT FLAME SCREEN FOR TANK VENT.
Condition: Unknown
Due 20 February 1986
Resolved 20 February 1986
Deck/Cargo
Issued 20 February 1986
Resolved
REPLACE MISSING GASKETS ON GENERATOR ROOM SUPPLY AND EXHAUST VENT COVERS.
Condition: Unknown
Due 20 February 1986
Resolved 20 February 1986
Lifesaving
Issued 20 February 1986
Resolved
REPAIR BOTH PORT SIDE DOORS AND RELEASING GEAR HATCHES GASKETS ON THE #2 LIFEBOAT.
Condition: Unknown
Due 20 February 1986
Resolved 20 February 1986
Electrical
Issued 20 February 1986
Resolved
REPLACE DETERIOATED STUFFING TUBE #2 LIFEBOAT ELECTRICAL SUPPLY TO WINCH CONTROLLER.
Condition: Unknown
Due 20 February 1986
Resolved 20 February 1986
Electrical
Issued 20 February 1986
Resolved
PROVE SATISFACTORY OPERATION OF THE WINCH CONTROLLER AND LIMIT SWITCHES ON THE #2 BOAT.
Condition: Unknown
Due 20 February 1986
Resolved 20 February 1986
Documentation
Issued 20 February 1986
Resolved
PROVIDE ON BOARD THE ORIGINAL CERTIFICATE OF INSPECTION.
Condition: Unknown
Due 20 February 1986
Resolved 20 February 1986
Electrical
Issued 20 February 1986
Resolved
PROVIDE EMERGENCY LIGHTING AT INFLATABLE LIFE RAFT STATION #2.
Condition: Unknown
Due 20 February 1986
Resolved 20 February 1986
Navigation
Issued 20 February 1986
Resolved
REPAIR OR REPLACE DAMAGED AIDS TO NAVIGATION BATTERIES.
Condition: Unknown
Due 20 February 1986
Resolved 20 February 1986
Navigation
Issued 20 February 1986
Resolved
CLEAN/REPLACE DAMAGED GENERAL ALARM BATTERIES.
Condition: Unknown
Due 20 February 1986
Resolved 20 February 1986
Fire Fighting
Issued 20 February 1986
Resolved
PROVIDE NON-CONDUCTIVE GLOVES FOR THE FIREMAN'S OUTFITS.
Condition: Unknown
Due 20 February 1986
Resolved 20 February 1986
Electrical
Issued 20 February 1986
Resolved
PROVIDE FLAT TIP SCREW DRIVER FOR THE TOOL KIT #2 LIFE BOAT AND PROVIDE 6' OF LINE FOR BOTH BUCKETS.
Condition: Unknown
Due 20 February 1986
Resolved 20 February 1986
Lifesaving
Issued 20 February 1986
Resolved
REPLACE DAMAGED LIFERING PORT STERN MAIN DECK.
Condition: Unknown
Due 20 February 1986
Resolved 20 February 1986
Deck/Cargo
Issued 20 February 1986
Resolved
REPLACE BROKEN GLASS IN THE CABS OF BOTH CRANES.
Condition: Unknown
Due 20 February 1986
Resolved 20 February 1986
Lifesaving
Issued 20 February 1986
Resolved
REPAIR BROKEN AND MISSING CAGING, EGRESS LADDERS BOTH BOW COLUMNS.
Condition: Unknown
Due 20 February 1986
Resolved 20 February 1986
Construction/Loadline
Issued 20 February 1986
Resolved
REPAIR DAMAGE HULL PLATING, BOTH STERN COLUMS AT THE 1 66' DRAFT. OUTER PLATING FRACTURED ON THE PORT COLUMN AND WORN THROUGH ON THE STARBOARD COLUMAN.
Condition: Unknown
Due 20 February 1986
Resolved 20 February 1986
Documentation
Issued 20 February 1986
Resolved
PROVIDE LOADLINE MARKINGS AS REQUIRED ON YOUR LOADLINE CERTIFICATE, REPAINTAS REQUIRED.
Condition: Unknown
Due 20 February 1986
Resolved 20 February 1986
Construction/Loadline
Issued 20 February 1986
Resolved
MAKE DOORS TO MUD PIT ROOMS SELF-CLOSING AND GAS TIGHT.
Condition: Unknown
Due 20 February 1986
Resolved 20 February 1986
Construction/Loadline
Issued 20 February 1986
Resolved
INSTALL GUARD OR WASTE OIL PUMP SHAFT.
Condition: Unknown
Due 20 February 1986
Resolved 20 February 1986
Electrical
Issued 20 February 1986
Resolved
INSTALL PROTECTIVE ELECTRICAL GRADE MAT IN BACK OF ACCESSIBLE SWITCHBOARDS.
Condition: Unknown
Due 20 February 1986
Resolved 20 February 1986
Deck/Cargo
Issued 20 February 1986
Resolved
REPAIR/REPLACE SAFETY SWITCHES ON ELEVATOR SHAFTS TO PORT & STARBOARD BALLAST PUMP.
Condition: Unknown
Due 20 February 1986
Resolved 20 February 1986
Documentation
Issued 20 February 1986
Resolved
PROVIDE ON BOARD (4) FOUR CERTIFIED LIFEBOATMAN DOCUMENTS OR GREATER DOCUMENT/LICENSE ONLY 3 PERSONS PROPERLY DOCUMENTED AT THE TIME OF THE INSPECTION.
Condition: Unknown
Due 20 February 1986
Resolved 20 February 1986
Navigation
Issued 20 February 1986
Resolved
PROVE SATISFACTORY OPERATION OF THE ELECTRONIC FOG HORN.
Condition: Unknown
Due 20 February 1986
Resolved 20 February 1986
Navigation
Issued 20 February 1986
Resolved
CLEAN LENS ON THE PORT STERN OBSTRUCTION LIGHT, PROVIDE LENS FOR THE PORT BOW OBSTRUCTION LIGHT, REPAIR/REPLACE LAMP BASE, STERN LIGHT.
Condition: Unknown
Due 20 February 1986
Resolved 20 February 1986
Documentation
Issued 20 February 1986
Resolved
RESUBMIT FIRE CONTROL PLAN FOR APPROVAL TO REFLECT CHANGE IN THE NUMBER OF INFLATABLE LIFE RAFTS.
Condition: Unknown
Due 20 February 1986
Resolved 20 February 1986
Electrical
Issued 20 February 1986
Resolved
PROVIDE MEANS FOR REMOTE SHUTDOWN OF THE FUEL OIL PURIFIER/TRANSFER PUMPS IN ACCORDANCE WITH 46 CFR 111.80-13, (CG-259), NVIC 4-78.
Condition: Unknown
Due 20 February 1986
Resolved 20 February 1986
Deck/Cargo
Issued 20 February 1986
Resolved
REMOVE EXISTING RELIEF VALVES ON HOT WATER HEATERS AND REPLACE WITH RELIEFS SET LESS THAN 100 PSIG MEETING ANSI STANDARD Z21.22; OR MAKE AVAILABLE FOR INTERNAL INSPECTION.
Condition: Unknown
Due 20 February 1986
Resolved 20 February 1986
Deck/Cargo
Issued 20 February 1986
Resolved
INSTALL HELICOPTER REFUELING HOSE ON REEL.
Condition: Unknown
Due 20 February 1986
Resolved 20 February 1986
Deck/Cargo
Issued 20 February 1986
Resolved
REMOVE RENEWABLE LINKS ON FUSES IN GENERAL ALARM PANEL.
Condition: Unknown
Due 20 February 1986
Resolved 20 February 1986
Lifesaving
Issued 20 February 1986
Resolved
REPAIR EMERGENCY TELEPHONE IN BALLAST PUMP ROOM.
Condition: Unknown
Due 20 February 1986
Resolved 20 February 1986
Lifesaving
Issued 20 February 1986
Resolved
FREE UP MANUAL SEACHEST VALVE FOR THE BALLAST SYSTEM IN THE STARBOARD BALLAST PUMP ROOM.
Condition: Unknown
Due 20 February 1986
Resolved 20 February 1986
Lifesaving
Issued 21 December 1984
Resolved
HYDRO THE AIR BOTTLES FOR THE #1 AND #2 LIFEBOATS. 46 CFR 147.041.
Condition: Unknown
Due 21 December 1984
Resolved 21 December 1984
Engineering
Issued 21 December 1984
Resolved
MAKE AVAILABLE FOR TESTING THE RELIEF VALVES LOCATED ON THE DRILL FLOOR AIR RECEIVERS. THIS TEST IS TO BE DONE IN THE PRESENCES OF A COAST GUARD MARINE INSPECTOR.
Condition: Unknown
Due 21 December 1984
Resolved 21 December 1984
Engineering
Issued 21 December 1984
Resolved
MAKE AVAILABLE FOR INTERNAL INSPECTION OR CONDUCT A HYDRO OF THE AIR RELIEVERS 2 EACH LOCATED AT THE DRILL FLOOR AND IN THE AQUA CHEM ROOM. THIS TEST OR INSPECTION IS TO BE DONE IN THE PRESENCE OF A COAST GUARD MARINE INSPECTOR.
Condition: Unknown
Due 21 December 1984
Resolved 21 December 1984
Engineering
Issued 21 December 1984
Resolved
MAKE AVAILABLE FOR TESTING THE AIR RELIEF VALVES LOCATED ON THE AIR RECEIVERS IN THE AQUA CHEM ROOM. TEST ARE TO BE DONE IN THE PRESENCE OF A U. S COAST GUARD MARINE INSPECTOR.
Condition: Unknown
Due 21 December 1984
Resolved 21 December 1984
Engineering
Issued 21 December 1984
Resolved
PROVIDE DOCUMENTATION OF A SATISFACTORY TEST OF ALL THE RELIEF DEVICES LOCATED ON THE 19 TENSIONER AIR BOTTLES. THE ABOVE TEST IS TO BE DONE IN THE PRESENCES OF A COAST GUARD MARINE INSPECTOR.
Condition: Unknown
Due 21 December 1984
Resolved 21 December 1984
Navigation
Issued 21 December 1984
Resolved
PROVIDE BOW AND STERN NAVIGATION LIGHTS. REF 72 COLREGS.
Condition: Unknown
Due 21 December 1984
Resolved 21 December 1984
Electrical
Issued 21 December 1984
Resolved
PROVIDE APPROVED HAZARDOUS LOCATION PLAN AND STARBOARD TO WHICH HAZARDOUS LOCATIONS DESIGNATED TO THE RIG. IF NO APPROVED PLAN SUBMIT ONE TO THE COAST GUARD FOR REVIEW. 46 CFR 110.25.
Condition: Unknown
Due 21 December 1984
Resolved 21 December 1984
Fire Fighting
Issued 21 December 1984
Resolved
UPDATE FIRE CONTROL PLAN REMOTE VENTILLATION SHUTDOWN IN BALLAST CONTROL ROOM NOT DEPICATED AND SUBMIT FOR USCG REVIEW. 46 CFR 107.305.
Condition: Unknown
Due 21 December 1984
Resolved 21 December 1984
Unknown
Issued 21 December 1984
Resolved
THE FOLLOWING DEFICIENCIES PERTAIN TO THE VESSEL PENROD 74, DN559440 AND ARE TO BE COMPLIED WITH BY 21DEC84.
Condition: Unknown
Due 21 December 1984
Resolved 21 December 1984
Unknown
Issued 21 December 1984
Resolved
PROVIDE AN APPROVED OPERATING MANUAL ON BOARD THE RIG. 46 CFR 109.121.
Condition: Unknown
Due 21 December 1984
Resolved 21 December 1984