MV FLING

Built
1974
Last inspected
9 June 2026
Documentation
Valid · NVDC file of 10 August 2026
Controls
None recorded without a removal date

Coast Guard record current through 23 August 2026, retrieved 5 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Passenger Ship class in Maury's sources begin in 2016.

Inspection record

Last inspected 9 June 2026
…with no type recorded4
Operational controls None recorded without a removal date
Years with a record 11 calendar years (2016–2026)
Every line above is a count of records the US Coast Guard wrote, or a date it recorded. A blank resolution means none was recorded in this data; it does not establish that a deficiency is outstanding. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Identity

WDA7435
Flag
UNITED STATES
Maury page id
psix-48117

Documentation record

Registered dimensions (L × B × D)96.7 ft × 21.7 ft × 7.1 ft
Registered tonnagegross 97 / net 66
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
BuilderSWIFTSHIPS INC · MORGAN CITY, LA, UNITED STATES · built 1974
Hull materialAluminum
PropulsionDiesel Reduction
Hull shapeUNSPECIFIED
Hull configurationUNSPECIFIED
Hailing portHOUSTON, TX
Endorsements, as the file codes themcw_un
DocumentationValid · issued 31 December 2025 · expires 31 January 2027
Service, as the file records itPassenger (Inspected)
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it97 - Regulatory (Subpart C or D), Gross Ton
66 - Regulatory (Subpart C or D), Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 August 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.
Professional
The full record for this vessel

Behind this panel: 29 inspections, each with its date, unit and type; 55 deficiencies with the resolution recorded against each; operational controls, none recorded without a removal date; no tow-unit appearances recorded; no other recorded names; the documentation record: dimensions, tonnage, builder, hailing port and endorsements. Every line is a record the Coast Guard wrote; the counts above are the same counts as in the summary, and they are free.

Professional is $39 a month or $299 a year, or $19.99 a month locked for life at the founding rate, for the first 200 subscribers. It unlocks every detail section on every vessel page, fleet watch tied to your account, and ownership records on request. Already a subscriber? Sign in.

Maury does not score, rate or grade vessels, at any price.

Vessel history report
Every record for this hull, in one document — $299

Every recorded inspection, 1972 to 2026, in one chronology · every deficiency, with system, dates and resolution · operational controls imposed and removed · every name this hull has been recorded under · the vessels it was inspected alongside, and when · how its record compares with hulls of similar age and size, as a fact about the population and never a judgement about this vessel.

Read one first, in full: a forty-year chronology · a hull that changed operators four times · the sparse case, shown as an example, not for sale.

This report is in development and is not for sale yet. There is no date, and nothing is charged. Leave an email and we will tell you when it exists, once.

Inspection history · 29

9 June 2026 Annual Inspection
Physical examination · Marine Safety Unit Texas City · USCG Heartland District (CGD-H) · Activity 8395538
20 January 2026 Vessel Attendance · Drydock Exam
Physical examination · Marine Safety Unit Texas City · USCG Heartland District (CGD-H) · Activity 8298867
20 May 2025 Annual Inspection
Physical examination · Marine Safety Unit Texas City · USCG Heartland District (CGD-H) · Activity 8140095
28 September 2024 In-Service Inspection
Physical examination · Marine Safety Unit Texas City · USCG Heartland District (CGD-H) · Activity 8011710
24 July 2024 Type not recorded
No type recorded · Marine Safety Unit Victoria · USCG Heartland District (CGD-H) · Activity 7966901
13 May 2024 Deficiency Check · COI Inspection
Physical examination · Marine Safety Unit Texas City · USCG Heartland District (CGD-H) · Activity 7911573
27 December 2023 Construction Oversight · Administrative Inspection
Physical examination · Marine Safety Unit Texas City · USCG Heartland District (CGD-H) · Activity 7842780
20 December 2023 Internal Structural Exam · Drydock Exam
Physical examination · Marine Safety Unit Texas City · USCG Heartland District (CGD-H) · Activity 7841285
6 September 2023 In-Service Inspection
Physical examination · Marine Safety Unit Texas City · USCG Heartland District (CGD-H) · Activity 7786264
5 August 2023 Type not recorded
No type recorded · Marine Safety Unit Texas City · USCG Heartland District (CGD-H) · Activity 7765094
7 March 2023 Annual Inspection · Internal Structural Exam
Physical examination · Marine Safety Unit Texas City · USCG Heartland District (CGD-H) · Activity 7647098
1 December 2022 In-Service Inspection · Administrative Inspection
Physical examination · Marine Safety Unit Texas City · USCG Heartland District (CGD-H) · Activity 7602549
21 January 2022 COI Inspection
Physical examination · Marine Safety Unit Texas City · USCG Heartland District (CGD-H) · Activity 7378229
8 December 2021 Internal Structural Exam · Drydock Exam
Physical examination · Marine Safety Unit Texas City · USCG Heartland District (CGD-H) · Activity 7364815
17 September 2021 In-Service Inspection
Physical examination · Marine Safety Unit Texas City · USCG Heartland District (CGD-H) · Activity 7314806
16 March 2021 Deficiency Check · Annual Inspection
Physical examination · Marine Safety Unit Texas City · USCG Heartland District (CGD-H) · Activity 7157408
15 May 2020 Administrative Inspection
Administrative · Marine Safety Unit Texas City · USCG Heartland District (CGD-H) · Activity 6953853
4 May 2020 Deficiency Check
Physical examination · Marine Safety Unit Texas City · USCG Heartland District (CGD-H) · Activity 6948047
22 April 2020 Annual Inspection · MTSA Verification
Physical examination · Marine Safety Unit Texas City · USCG Heartland District (CGD-H) · Activity 6942557
6 December 2019 Internal Structural Exam · Drydock Exam
Physical examination · Marine Safety Unit Texas City · USCG Heartland District (CGD-H) · Activity 6868779
2 October 2019 In-Service Inspection
Physical examination · Marine Safety Unit Texas City · USCG Heartland District (CGD-H) · Activity 6826636
11 April 2019 Annual Inspection
Physical examination · Marine Safety Unit Texas City · USCG Heartland District (CGD-H) · Activity 6660862
25 July 2018 Type not recorded
No type recorded · Station Freeport · USCG Heartland District (CGD-H) · Activity 6512870
6 March 2018 Annual Inspection
Physical examination · Marine Safety Unit Texas City · USCG Heartland District (CGD-H) · Activity 6367140
14 November 2017 Drydock Exam
Physical examination · Marine Safety Unit Texas City · USCG Heartland District (CGD-H) · Activity 6306971
14 August 2017 Type not recorded
No type recorded · Marine Safety Unit Texas City · USCG Heartland District (CGD-H) · Activity 6306234
30 January 2017 MTSA Verification · Internal Structural Exam · COI Inspection · Administrative Inspection
Physical examination · Marine Safety Unit Texas City · USCG Heartland District (CGD-H) · Activity 6079373
12 April 2016 Annual Inspection · Deficiency Check
Physical examination · Marine Safety Unit Texas City · USCG Heartland District (CGD-H) · Activity 5852203
12 January 2016 Examination of Repairs · Drydock Exam · Internal Structural Exam
Physical examination · Marine Safety Unit Texas City · USCG Heartland District (CGD-H) · Activity 5796165

Deficiency record · 55

08 - Alarms › N/A - No Subsystem › Other (alarms)
Issued 9 June 2026 Resolved
A visual and audible alarm must be provided at the operating station to indicate high water level in a machinery space bilge. Bilge alarm in engine room did not operate. 46 CFR 182.530
Action required: 701 - Prior to carriage of passengers/cargo
Due 19 June 2026
Resolved 11 June 2026
Resolution: MI attended vessel and witnessed satisfactory operation.
07 - Fire Safety › N/A - No Subsystem › Fire detection and alarm system
Issued 9 June 2026 Resolved
Vessels described by 46 CFR 175.110(c) must have an interconnected fire detection system in compliance with § 181.450 installed in all enclosed areas where passengers and crew have routine access, including accommodation spaces and machinery spaces. 46 CFR 181.405 Visual alarm for interconnected fire detection system did not operate in the engine room.
Action required: 701 - Prior to carriage of passengers/cargo
Due 19 June 2026
Resolved 11 June 2026
Resolution: MI attended vessel and witnessed satisfactory operation.
04 - Emergency Systems › N/A - No Subsystem › Emergency, lighting, batteries and switches
Issued 9 June 2026 Resolved
Each vessel must have adequate emergency lighting fitted along the line of escape to the main deck from all passenger and crew accommodations spaces located below the main deck. Emergency lighting did not properly operate in the aft passageway. 46 CFR 183.432
Action required: 701 - Prior to carriage of passengers/cargo
Due 19 June 2026
Resolved 11 June 2026
Resolution: MI attended vessel and witnessed satisfactory operation.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 9 June 2026 Resolved
The master shall conduct sufficient drills and give sufficient instructions to make sure that all crew members are not familiar with their duties during emergencies that necessitate abandoning ship or the recovery of persons who have fallen overboard. Vessel has not conducted any drills since being in service from dry dock completion in March. Unable to get underway to complete drills on day of inspection. 46 CFR 185.520
Action required: 701 - Prior to carriage of passengers/cargo
Due 19 June 2026
Resolved 11 June 2026
Resolution: MI attended vessel and witnessed satisfactory MOB drill.
07 - Fire Safety › N/A - No Subsystem › Oil accumulation in engine room
Issued 20 May 2025 Resolved
At each inspection for certification and at every other vessel inspection the bilges and other spaces may be examined to see that there is no excessive accumulation of oil, trash, debris, or other matter that might create a fire hazard, clog bilge pumping systems, or block emergency escapes. MI identified an excess of oily water beneath center MDE. Vessel is to remove water to satisfaction of the Coast Guard prior to the carriage of passengers.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 21 May 2025
Resolution: Photo evidence provided.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Doors
Issued 20 May 2025 Resolved
For each watertight door which is in a required subdivision bulkhead, an indicator light must be installed in the pilothouse and at each other vessel operating station from which the door is not visible. The indicator must show whether the door is open or closed. MI identified vessel having a mixed audible and visual alarm for engine room watertight door that continued to sound when door was closed. Vessel is instructed to correct both audible and visual prior to carriage of passengers.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 21 May 2025
Resolution: Photo evidence provided.
09 - Working and Living Conditions › 091 - Living Conditions › Electrical devices
Issued 20 May 2025 Resolved
Electrical equipment on a vessel must be installed and maintained to protect passengers, crew, other persons, and the vessel from electrical hazards, including fire, caused by or originating in electrical equipment, and electrical shock. MI identified multiple loose wirings in the engineering space. Vessel is to identify any and all loose/peeling wires within engine room, then remove or replace in accordance with CFR requirements.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 3 June 2025
Resolved 21 May 2025
Resolution: Photo evidence provided.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 20 May 2025 Resolved
The exhaust piping must be so arranged as to prevent backflow of water from reaching engine exhaust ports under normal conditions. MI identified leaking of water from exhaust port on starboard engine. Vessel is to enact repairs to satisfaction of the CG.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 3 June 2025
Resolved 21 May 2025
Resolution: installed temp patches
03 - Water/Weathertight Conditions › N/A - No Subsystem › Scuppers, inlets and discharges
Issued 20 May 2025 Resolved
Inspection and operation of all watertight closures in the hull, decks, and bulkheads including through hull fittings and sea valves. MI identified a leak on the starboard shaft seal. Vessel is to enact repairs to the satisfaction of the CG
Action required: 16 - Rectify deficiencies w/in 14 days
Due 3 June 2025
Resolved 21 May 2025
Resolution: Photo evidence provided.
08 - Alarms › N/A - No Subsystem › Fire alarm
Issued 13 May 2024 Resolved
An interconnected detection and alarm system must: Be installed such that the actuation of alarm in one area results in both audible and visual alarms in all areas required by 46 CFR 181.405(c) or 118.400(d) to be protected by the interconnected detection and alarm system. MI discovered the alarm system in main engine space and steering gear without visual indicators.
Condition: Improper Installation
Action required: 701 - Prior to carriage of passengers/cargo
Due 12 June 2024
Resolved 7 June 2024
Resolution: Vessel rep submitted videos of properly operating visual alarms upon smoke detection
04 - Emergency Systems › N/A - No Subsystem › Emergency, lighting, batteries and switches
Issued 13 May 2024 Resolved
Each vessel must have adequate emergency lighting fitted along the line of escape to the main deck from all passenger and crew accommodation spaces located below the main deck. MI discovered an aft berthing fwd emergency light inoperable.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 12 June 2024
Resolved 7 June 2024
Resolution: Vessel rep submitted photos of properly operating emergency lighting
09 - Working and Living Conditions › 092 - Working Conditions › Protection machinery
Issued 13 May 2024 Resolved
An exposed hazard, such as gears or rotating machinery, must be properly protected by a cover, guard, or rail. MI found a compressor in the main engine space without a guard.
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 12 June 2024
Resolved 7 June 2024
Resolution: Vessel rep submitted photos of machinery guards in place
03 - Water/Weathertight Conditions › N/A - No Subsystem › Machinery space openings
Issued 13 May 2024 Resolved
A penetration in a watertight bulkhead must be as high and as far inboard in the bulkhead as practicable, and made watertight. MI discovered two holes in a machinery space bulkhead.
Condition: Damaged By Earlier Event
Action required: 10 - Deficiency Rectified
Due 5 June 2024
Resolved 5 June 2024
Resolution: Rectified on the spot
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 13 May 2024 Resolved
Where flexibility is necessary, a section of flexible metallic hose may be used. Nonmetallic hose may be used for wet exhaust systems provided it is especially adapted to resist the action of oil, acid, and heat, has a wall thickness sufficient to prevent collapsing or panting, and is double clamped where practicable. MI discovered a missing clamp on the starboard engine exhaust cooling water hose.
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Due 5 June 2024
Resolved 5 June 2024
Resolution: Rectified on spot
07 - Fire Safety › N/A - No Subsystem › Means of escape
Issued 27 December 2023 Resolved
Vessels described by 46 CFR 175.110(d) must ensure that the two means of escape required in paragraph (b) of this section are unobstructed and the door, hatch, or scuttle is not located directly above, or dependent on, a berth. The interior pilothouse door is designed so that there is potential for the door to obstruct the aft vertical means of escape from the forward accommodation space. Remove or reconfigure the door so there is no potential to obstruct the means of escape. Affect repairs/alterations prior to carriage of passengers in the forward accommodation space to the satisfaction of USCG.
Action required: 701 - Prior to carriage of passengers/cargo
Due 10 May 2024
Resolved 5 June 2024
Resolution: MI verified means of escape during COI inspection
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 21 January 2022 Resolved
On vessels where the certificate of inspection is renewed less often than annually, a marine inspector must check the settings of the safety relief valves on all pressure vessels twice every five years. No more than 3 years may elapse between checks. MI could not verify settings during COI. Prove proper operation of pressure relief valve to the satisfaction of attending marine inspector. 46 CFR 61.10-5(i)2
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 4 February 2022
Resolved 24 January 2022
Resolution: Provided satisfactory evidence of pressure relieve valve operation to MI.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 16 March 2021 Resolved
46 CFR 182.510(a), 46 CFR 182.520 Table A vessel must be provided with a satisfactory arrangement for draining any watertight compartment, other than small buoyancy compartments, under all practicable conditions.A vessel more than 19.8m (65 ft) is required 2 fixed power pumps with a minimum capacity rating of 190 LPM (50 GPM). The bilge system is inoperable and will not pump out any space.
Action required: 701 - Prior to carriage of passengers/cargo
Due 23 March 2021
Resolved 29 March 2021
Resolution: Witnessed operation of the vessel's bilge system.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Manholes/flush scuttles
Issued 16 March 2021 Resolved
46 CFR 179.360 Each hatch exposed to the weather must be watertight. The engine room emergency exit hatch will not fully seat, allowing for the chance for down flooding.
Action required: 701 - Prior to carriage of passengers/cargo
Due 23 March 2021
Resolved 29 March 2021
Resolution: Witnessed operation of the engine room emergency exit deck hatch to include being fully closed and locked.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 16 March 2021 Resolved
46 CFR 183.200 Electrical equipment on a vessel must be installed and maintained to: (b) Protect passengers, crew, other persons, and the vessel from electrical hazards, including fire, caused by or originating in electrical equipment and electrical shock. Shore tie is repaired with electrical tape. Make proper repairs to the damage shore tie cable.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 30 March 2021
Resolved 29 March 2021
Resolution: Vessel installed a new shoretie.
04 - Emergency Systems › N/A - No Subsystem › Emergency, lighting, batteries and switches
Issued 16 March 2021 Resolved
46 CFR 183.432 Each vessel must have adequate emergency lighting fitted along the escape to the main deck from all passenger and crew accommodation spaces. A source of emergency lighting is required in the aft portion of the galley space in the vicinity of the exit.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 30 March 2021
Resolved 29 March 2021
Resolution: Vessel installed new LED emergency lighting in the space required.
04 - Emergency Systems › N/A - No Subsystem › Functionality of Safety Systems
Issued 16 March 2021 Resolved
46 CFR 183.310(a)(1) Each vessel that relies on electricity to power the following loads must be arranged so that the loads can be energized from two sources of electricity: (ii)Interior lighting except for decorative lighting. (iii) Communication systems including a public address system. Emergency lighting and radio is inoperable on the back-up battery when the power to the vessel is secured.
Action required: 701 - Prior to carriage of passengers/cargo
Due 23 March 2021
Resolved 29 March 2021
Resolution: Vessel replaced the emergency battery. Conducted successful checks of the emergency lighting system and radio operation.
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 22 April 2020 Resolved
Monthly inspections required by NFPA 10 may be conducted by the owner, operator, person-in-charge, or a designated member of the crew. Vessel must provide training to crew for monthly inspections/ monthly inspection logs to the satisfaction of the MI.
Condition: Damaged By Earlier Event
Action required: 50 - Rectify deficiencies w/in 30 days
Due 23 May 2020
Resolved 4 May 2020
Resolution: Crew training for monthly portable fire extingusiher checks/and how to log them was conducted on 01MAY2020.
10 - Safety of Navigation › N/A - No Subsystem › Lights, shapes, sound-signals
Issued 22 April 2020 Resolved
The sidelights of vessels of 20 meters or more in length shall be fitted with matt black inboard screens and meet the requirements of §84.15. On vessels of less than 20 meters in length, the sidelights, if necessary to meet the requirements of §84.15, shall be fitted with matt black inboard screens. With a combined lantern, using a single vertical filament and a very narrow division between the green and red sections, external screens need not be fitted. Port and Starboard navigation light screens are wasted and must be replaced to the satisfaction of the attending MI.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 23 May 2020
Resolved 4 May 2020
Resolution: The port and starboard screens were replaced and painted matt black.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 22 April 2020 Resolved
Materials used in piping systems must meet the requirements of this subpart and be otherwise acceptable to the cognizant OCMI. Vessel must replace piping to the satisfaction of the attending MI. Must be completed at next DD.
Condition: Damaged By Earlier Event
Action required: 705 - Other - as specified
Resolved 21 January 2022
Resolution: Vessel renewed affected piping during December 2021 Drydock period to the satisfaction of attending MI.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Operation of machinery
Issued 22 April 2020 Resolved
Shutoff valves, installed so as to close against the fuel flow, must be fitted in the fuel supply lines, one at the tank connection and one at the engine end of the fuel line to stop fuel flow when servicing accessories. The shutoff valve at the tank must be manually operable from outside the compartment in which the valve is located, preferably from an accessible position on the weather deck. If the handle to the shutoff valve at the tank is located inside the machinery space, it must be located so that the operator does not have to reach more than 300 millimeters (12 inches) into the machinery space and the valve handle must be shielded from flames by the same material the hull is constructed of, or some noncombustible material. Electric solenoid valves must not be used, unless used in addition to the manual valve. MI discovered that the reach rod used to shut off the fuel supply was secured by a cotter pin that was not properly installed. Vessel rectified deficiency to the satisfaction of the MI.
Condition: Improper Installation
Action required: 10 - Deficiency Rectified
Resolved 22 April 2020
10 - Safety of Navigation › N/A - No Subsystem › Nautical publications
Issued 22 April 2020 Resolved
As appropriate for the intended voyage, a vessel must carry adequate and up-to-date: Charts of large enough scale to make safe navigation possible, U.S. Coast Pilot or similar publication, Coast Guard Light List, Tide tables, and Current tables. Vessel must obtain current publications to the satisfaction of the attending MI.
Condition: Invalid
Action required: 50 - Rectify deficiencies w/in 30 days
Due 23 May 2020
Resolved 4 May 2020
Resolution: POC provided 2020 editions of the above mentioned publications.
05 - Radio Communications › N/A - No Subsystem › Satellite EPIRB 406MHz/1.6GHz
Issued 22 April 2020 Resolved
Each vessel that operates on the high seas, or that operates beyond three miles from the coastline of the Great Lakes, must have on board a FCC Type Accepted Category 1, 406 MHz EPIRB, installed to automatically float free and activate. MI's discovered that EPIRB Hydrostatic Release expired in June of 2019. Vessel is required to install an approved Hydrostatic Release to the satisfaction of the attending MI.
Condition: Improper/Lack of Maintenance
Action required: 30 - Ship detained
Due 22 April 2020
Resolved 4 May 2020
Resolution: The hydrostatic release was an approved type and not expired.
04 - Emergency Systems › N/A - No Subsystem › Public address system
Issued 22 April 2020 Resolved
A vessel with more than one passenger deck and a vessel with overnight accommodations must have the public address system operable from the operating station. MI's discovered that PA system was non operational. Vessel is required to rectify system to the satisfaction of the attending MI.
Condition: Damaged By Earlier Event
Action required: 30 - Ship detained
Due 22 April 2020
Resolved 4 May 2020
Resolution: The PA system was satisfactorily tested and found to be operational.
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 22 April 2020 Resolved
A fire hose with a nozzle must be attached to each fire hydrant at all times. For fire hydrants located on open decks or cargo decks, where no protection is provided, hoses may be temporarily removed during heavy weather or cargo handling operations, respectively. Hoses so removed must be stored in nearby accessible locations. One of the two fire hoses on board did not have a brass fitting to attach to the fire hydrant. Vessel must replace fire hose to the satisfaction of the attending MI.
Condition: Damaged By Earlier Event
Action required: 30 - Ship detained
Due 22 April 2020
Resolved 4 May 2020
Resolution: The brass fitting was replaced on the fire hose.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 22 April 2020 Resolved
Electrical equipment exposed to the weather must be watertight. The junction box on the port aft side of the deck must be replaced to the satisfaction of the attending MI.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 23 May 2020
Resolved 4 May 2020
Resolution: The junction bock was replaced is now watertight.
01 - Certificates & Documentation › 013 - Documents › Log-books/compulsory entries
Issued 22 April 2020 Resolved
Abandon ship and man overboard drills and training shall be logged or otherwise documented for review by the Coast Guard upon request. Abandon ship drills and man overboard drills were not properly logged. Vessel must provide training to personnel on the proper format of the drills log to the satisfaction of the MI.
Condition: Invalid
Action required: 50 - Rectify deficiencies w/in 30 days
Due 23 May 2020
Resolved 4 May 2020
Resolution: Conducted crew training on 01MAY2020 to demontrate how to properly log drills.
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 22 April 2020 Resolved
Portable fire extinguishers must be located so that they are clearly visible and readily accessible from the space being protected. The installation and location must be to the satisfaction of the Officer in Charge, Marine Inspection. E/R portable extinguisher bracket is wasted and must be replaced to the satisfaction of the attending MI.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 6 May 2020
Resolved 4 May 2020
Resolution: A new portable fire extinguisher bracket was mounted on the forward engine room bulkhead.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 22 April 2020 Resolved
Each ungrounded system must be provided with a suitably sensitive ground detection system located at the respective switchboard that provides continuous indication of circuit status to ground with a provision to momentarily remove the indicating device from the reference ground. MI's discovered that continuous indication status was not able to be removed. Vessel must meet the intent of the regulation to the satisfaction of the attending MI.
Condition: Damaged By Earlier Event
Action required: 16 - Rectify deficiencies w/in 14 days
Due 6 May 2020
Resolved 4 May 2020
Resolution: The switchboard was found to be operating in satisfactory condition after the ground was removed from the vessel.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 22 April 2020 Resolved
A vessel's hull must not carry current as a conductor. The switchboard displayed a ground. Vessel must rectify the ground to the satisfaction of the attending MI.
Condition: Invalid
Action required: 16 - Rectify deficiencies w/in 14 days
Due 6 May 2020
Resolved 4 May 2020
Resolution: The ground wire was discovered inside a junction box and realigned outside the junction box. The ground was removed.
07 - Fire Safety › N/A - No Subsystem › Oil accumulation in engine room
Issued 22 April 2020 Resolved
Fire hazards to be minimized. The general construction of the vessel must be such as to minimize fire hazards insofar as it is reasonable and practicable. Excessive amount of oil/oily water found in engine room bilges creating fire/pollution hazard. Remove oil/oily water from bilges.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 22 April 2020
Resolved 4 May 2020
Resolution: The excessive amount of oil/oily water was removed from the engine room bilges.
09 - Working and Living Conditions › 092 - Working Conditions › Cleanliness of engine room
Issued 11 April 2019 Resolved
Excessive amount of oil/oily water found in engine room bilges creating fire/pollution hazard. Remove oil/oily water from bilges.
Action required: 701 - Prior to carriage of passengers/cargo
Due 11 April 2019
Resolved 25 April 2019
Resolution: All oil and oily water was properly removed from vsl bilges.
07 - Fire Safety › N/A - No Subsystem › Oil accumulation in engine room
Issued 11 April 2019 Resolved
Excessive oily dirt/grime found caked on the engine room exhaust fan and fan housing creating a fire hazard. Clean fan and fan housing of excessive caked on oil. Recommended to vessel operator to properly re-install missing crank case exhaust filters as originally provided by MDE manufacture.
Action required: 701 - Prior to carriage of passengers/cargo
Due 11 April 2019
Resolved 25 April 2019
Resolution: Engine room vent fan and housing has been cleaned of excess oil/oily dirt.
07 - Fire Safety › N/A - No Subsystem › Means of escape
Issued 11 April 2019 Resolved
Emergency escape hatch from the machinery and auxiliary Mech space were found seized, requiring mechanical force to open. Repair/Service all escape hatches and prove proper operation to the satisfaction of the attending marine inspector
Action required: 701 - Prior to carriage of passengers/cargo
Due 11 April 2019
Resolved 25 April 2019
Resolution: Verified all escape hatches have been freed and adjusted to allow easy operation and opening.
09 - Working and Living Conditions › 092 - Working Conditions › Other (accident prevention)
Issued 11 April 2019 Resolved
Found dive tanks, boxes and gear adrift in the rudder compartment in close proximity to the rudder steering arms and linkage rod. This condition could create an unsafe operational condition. Remove all loose/adrift gear and properly secure away from steering equipment.
Action required: 701 - Prior to carriage of passengers/cargo
Due 11 April 2019
Resolved 25 April 2019
Resolution: Rudder room cleared of all loose gear and safety hazards.
02 - Structural Conditions › N/A - No Subsystem › Steering gear
Issued 11 April 2019 Resolved
Port side steering ram has a hydraulic hose that is dry rotted and is showing signs of excessive deterioration. Remove and replace hose.
Action required: 701 - Prior to carriage of passengers/cargo
Due 11 April 2019
Resolved 25 April 2019
Resolution: Damaged hose has been replaced in kind.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Doors
Issued 11 April 2019 Resolved
Class III WTD separating the machinery space from the Aux machinery space has several hydraulic oil leaks coming from the hydraulic piping associated with the actuator used for opening and closing of the door. Effect repairs and prove proper operation of the installed WTD.
Action required: 701 - Prior to carriage of passengers/cargo
Due 11 April 2019
Resolved 25 April 2019
Resolution: WTD hydraulic lines have been repaired and found to not leak during operation of the opening system.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 11 April 2019 Resolved
The fuel shut of valve, to the port main diesel engine, could not be secured with the use of the reach rod. Repair and prove proper operation of the shut off valve with the use of the reach rod.
Action required: 701 - Prior to carriage of passengers/cargo
Due 11 April 2019
Resolved 25 April 2019
Resolution: Tested MDE fuel shutoff reach rods, all found sat.
Fire Fighting › Fire Main › Condition
Issued 6 March 2018 Resolved
Approx 15ft of fire main was found to be wasted in several location.
Action required: 60 - Rectify deficiencies prior to movement
Resolved 14 March 2018
Engineering › Fuel Oil Service System › Hose
Issued 6 March 2018 Resolved
Port SSDG has high pressure fuel hoses with unapproved fittings. Fuel hoses have metal hose clamps on each side.
Action required: 60 - Rectify deficiencies prior to movement
Resolved 14 March 2018
Operations/Management › Drills/Instruction › Fire
Issued 6 March 2018 Resolved
Vsl was unable to get underway to conduct abandon ship drill or fire drill due to unsafe condition of fuel system and fire main system.
Action required: 60 - Rectify deficiencies prior to movement
Resolved 14 March 2018
Lifesaving › Hand Flares › Approval
Issued 6 March 2018 Resolved
04 of the 06 required red hand flares onboard are not CG approved.
Action required: 60 - Rectify deficiencies prior to movement
Resolved 14 March 2018
Lifesaving › Lifejacket/PFD (Type I) › Storage
Issued 6 March 2018 Resolved
Lifejacket stowage was not properly labled with number of lifejackets stowed inside.
Due 20 March 2018
Resolved 14 March 2018
Lifesaving › Lifebuoys › Markings (ship name/port)
Issued 6 March 2018 Resolved
03 lifebuoys found to have markings worn off.
Due 20 March 2018
Resolved 14 March 2018
Engineering › Steering Gear System › Hydraulic Hose
Issued 6 March 2018 Resolved
Port side steering gear hoses are wasted.
Due 20 March 2018
Resolved 14 March 2018
Electrical › Electric Supply System (service) › Battery Charger
Issued 31 January 2017 Resolved
Improperly installed battery charger for winch on back deck, zip tied wires and power strip to bulkhead.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 28 February 2017
Resolved 16 February 2017
Resolution: Rcvd satisfactory pictures of the removal of the power strip and proper installation of cable to the battery charger in the aft steering.
Lifesaving › Lifejacket/PFD (Type I) › Condition
Issued 12 April 2016 Resolved
44 life jackets had its internal flotation material deteriorate to the point of non-serviceability. Replace all prior to carrying passengers.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 12 April 2016
Resolved 21 April 2016
Resolution: 44 new life jackets have been place onboard, all sat.
Communications › Radio Communications › EPIRB
Issued 12 April 2016 Resolved
EPIRB has missing registration sticker, expired battery and expired hydro static release device. No operations beyond the 3 miles allowed.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 12 April 2016
Resolved 21 April 2016
Resolution: EPIRB has been properly registered, had battery replaced and properly mounted with new hydro-static unit.
Construction/Loadline › Structures › Door
Issued 12 April 2016 Resolved
Class II water tight door did not have a functioning open door indicator light. Repair indicator light to indicate when water tight door is open at any position.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 12 May 2016
Resolved 21 April 2016
Resolution: Verifed the vessel had a properly operating open/close indictor light for its Type II WTD.
Engineering › Fuel Oil Storage/Transfer System › Valve
Issued 12 April 2016 Resolved
Port side remote fuel shutoff valve not operable.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 12 May 2016
Resolved 21 April 2016
Resolution: Satisfactorily tested portside remote fuel shutoff valve.
Engineering › Compressed Air System (control) › Valve
Issued 12 April 2016 Resolved
Control air system could not be utilized to transfer main control to the remote operating station.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 12 April 2016
Resolved 22 April 2016
Resolution: Replaced cut O-ring on the main air control valve and cleaned out the remote location stations unit. Tested sat.

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.