MAURY USCG vessel records
← All vessels

CAPTREE PRINCESS

CAPTREE PRINCESS is a 1974 passenger vessel (inspected). The Coast Guard has recorded 20 inspections since 2016, most recently in April 2026, along with 55 deficiencies — 2 with no resolution recorded — and 1 casualty investigation in 2024.

Records from 2016 to 2026. Most recent: inspection, 22 April 2026.

Built
1974
Last inspected
22 April 2026
Documentation
Valid · documentation file of 10 August 2026
Controls
None recorded without a removal date

Coast Guard record current through 23 August 2026, retrieved 5 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Passenger Ship class in Maury's sources begin in 2016.

Inspection record

Last inspected 22 April 2026
…with no type recorded3
…past their stated due date2
Operational controls None recorded without a removal date
Years with a record 11 calendar years (2016–2026)
Every line above is a count of records the US Coast Guard wrote, or a date it recorded. A blank resolution means none was recorded in this data; it does not establish that a deficiency is outstanding. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Identity

WDH7957
Flag
UNITED STATES
Maury page id
psix-48119

Documentation record

Registered dimensions (L × B × D)73.3 ft × 22.0 ft × 6.7 ft
Registered tonnagegross 56 / net 38
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
BuilderGULF CRAFT INC · PATTERSON, LA, UNITED STATES · built 1974
Hull materialAluminum
PropulsionDiesel Reduction
Hull shapeUNSPECIFIED
Hull configurationUNSPECIFIED
Hailing portNEW YORK, NY
Trade endorsementsCoastwise, unrestricted, Fishery
DocumentationValid · issued 25 March 2026 · expires 31 March 2027
Service, as the file records itPassenger (Inspected)
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it56 - Regulatory (Subpart C or D), Gross Ton
38 - Regulatory (Subpart C or D), Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 August 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.
Vessel history report
Every record for this hull, in one document — $299

Every recorded inspection, 2016 to 2026 for this class, in one chronology · every deficiency, with system, dates and resolution · operational controls imposed and removed · every name this hull has been recorded under · the vessels it was inspected alongside, and when · how its record compares with hulls of similar age and size, as a fact about the population and never a judgement about this vessel.

Read one first, in full: a forty-year chronology · a hull that changed operators four times · the sparse case, shown as an example, not for sale.

This report is in development and is not for sale yet. There is no date, and nothing is charged. Leave an email and we will tell you when it exists, once.

Inspection history · 20

22 April 2026 Deficiency Check · Annual Inspection
Physical examination · Marine Safety Unit Coram · USCG Northeast District (CGD-NE) · Activity 8353217
7 May 2025 Internal Structural Exam · Administrative Inspection · Annual Inspection · Deficiency Check
Physical examination · Marine Safety Unit Coram · USCG Northeast District (CGD-NE) · Activity 8130157
2 June 2024 Type not recorded
No type recorded · Marine Safety Unit Coram · USCG Northeast District (CGD-NE) · Activity 7926774
1 May 2024 Administrative Inspection · Internal Structural Exam · COI Inspection
Physical examination · Marine Safety Unit Coram · USCG Northeast District (CGD-NE) · Activity 7904767
4 April 2024 Type not recorded
No type recorded · Marine Safety Unit Coram · USCG Northeast District (CGD-NE) · Activity 7895337
12 December 2023 Drydock Exam · Administrative Inspection · Internal Structural Exam
Physical examination · Marine Safety Unit Coram · USCG Northeast District (CGD-NE) · Activity 7837952
22 May 2023 Annual Inspection · Deficiency Check · Administrative Inspection · Internal Structural Exam
Physical examination · Marine Safety Unit Coram · USCG Northeast District (CGD-NE) · Activity 7710408
26 April 2022 Deficiency Check · Annual Inspection · DAPI Audit
Physical examination · Marine Safety Unit Coram · USCG Northeast District (CGD-NE) · Activity 7437890
18 March 2022 Internal Structural Exam · Drydock Exam
Physical examination · Marine Safety Unit Coram · USCG Northeast District (CGD-NE) · Activity 7413636
7 May 2021 DAPI Audit · Deficiency Check · Annual Inspection
Physical examination · Marine Safety Unit Coram · USCG Northeast District (CGD-NE) · Activity 7191007
10 November 2020 Type not recorded
No type recorded · Station Fire Island · USCG Northeast District (CGD-NE) · Activity 7093042
27 May 2020 Administrative Inspection · Deficiency Check · COI Inspection
Physical examination · Marine Safety Unit Coram · USCG Northeast District (CGD-NE) · Activity 6955315
9 March 2020 Internal Structural Exam · Administrative Inspection · Hull Examination
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 6943824
3 October 2019 Administrative Inspection · In-Service Inspection
Physical examination · Marine Safety Unit Coram · USCG Northeast District (CGD-NE) · Activity 6826654
29 March 2019 Internal Structural Exam · Annual Inspection
Physical examination · Marine Safety Unit Coram · USCG Northeast District (CGD-NE) · Activity 6645223
18 April 2018 Annual Inspection · Internal Structural Exam
Physical examination · Marine Safety Unit Coram · USCG Northeast District (CGD-NE) · Activity 6336291
8 February 2018 Inclining Experiment · Drydock Exam
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 6630766
26 April 2017 Administrative Inspection · Internal Structural Exam · Annual Inspection
Physical examination · Marine Safety Unit Coram · USCG Northeast District (CGD-NE) · Activity 6131577
2 December 2016 Internal Structural Exam · Hull Examination
Physical examination · Marine Safety Unit Coram · USCG Northeast District (CGD-NE) · Activity 6051219
6 April 2016 Internal Structural Exam · Annual Inspection
Physical examination · Marine Safety Unit Coram · USCG Northeast District (CGD-NE) · Activity 5848540

Deficiency record · 55

03 - Water/Weathertight Conditions › N/A - No Subsystem › Covers (hatchway-, portable-, tarpaulins, etc.)
Issued 22 April 2026 Resolved
Attach securing device on all deck hatches.
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Due 30 April 2026
Resolved 22 April 2026
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 22 April 2026 Resolved
Mount bilge pump float switch in forepeak
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Due 29 April 2026
Resolved 22 April 2026
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 22 April 2026 Resolved
Renew one life ring
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 29 April 2026
Resolved 23 April 2026
Resolution: Purchased new.
05 - Radio Communications › N/A - No Subsystem › VHF EPIRB
Issued 22 April 2026 Resolved
Obtain new hydrostatic release for EPIRB
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 7 May 2026
Resolved 23 April 2026
Resolution: purchased replacement
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 22 April 2026 Resolved
Install non conductive mat in from of switchboard in engine room
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 6 May 2026
Resolved 23 April 2026
Resolution: Purchased replacement.
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 22 April 2026 Resolved
Install replacement nozzle for port side fire hose
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 6 May 2026
Resolved 23 April 2026
Resolution: Purchased replacement
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 22 April 2026 Resolved
Replace fire hose on starboard side
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 6 May 2026
Resolved 23 April 2026
Resolution: Purchased replacement
09 - Working and Living Conditions › 091 - Living Conditions › Sleeping room
Issued 22 April 2026 Resolved
Mount emergency exit reflective stickers and install in bunk room
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 6 May 2026
Resolved 23 April 2026
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 22 April 2026 Resolved
Remove dead end wires in engine room as discussed
Action required: 16 - Rectify deficiencies w/in 14 days
Due 6 May 2026
Resolved 23 April 2026
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 22 April 2026 Resolved
Replace 2 spanner wrenches for fire hoses
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 6 May 2026
Resolved 23 April 2026
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 22 April 2026 Resolved
Post life jacket donning placard
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 6 May 2026
Resolved 23 April 2026
09 - Working and Living Conditions › 092 - Working Conditions › Lighting (Working spaces)
Issued 22 April 2026 No resolution recorded
Install replacement globes in engine room light fixtures
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 6 May 2026 — due date passed with no resolution recorded
09 - Working and Living Conditions › 091 - Living Conditions › Sleeping room
Issued 22 April 2026 No resolution recorded
Post bunk room escape plan
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 6 May 2026 — due date passed with no resolution recorded
10 - Safety of Navigation › N/A - No Subsystem › Lights, shapes, sound-signals
Issued 7 May 2025 Resolved
Prior to operating at night or during periods of reduced visibility prove proper operation of fore mast and stern lights.
Condition: Placed in Improper Service
Action required: 705 - Other - as specified
Due 7 May 2025
Resolved 9 May 2025
11 - Life Saving Appliances › N/A - No Subsystem › Other (life saving)
Issued 7 May 2025 Resolved
Post life jacket donning placard and emergency instructions.
Condition: Placed in Improper Service
Action required: 16 - Rectify deficiencies w/in 14 days
Due 21 May 2025
Resolved 12 May 2025
02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 7 May 2025 Resolved
Renew / repair cracked section of handrail on main deck starboard side. Prohibit passengers from area where compromised.
Condition: Damaged By Earlier Event
Action required: 16 - Rectify deficiencies w/in 14 days
Due 21 May 2025
Resolved 9 May 2025
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 7 May 2025 Resolved
Renew port side fire hose with lined commercial fire hose UL-19.
Condition: Damaged By Earlier Event
Action required: 701 - Prior to carriage of passengers/cargo
Due 7 May 2025
Resolved 9 May 2025
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 7 May 2025 Resolved
Check/ renew protective cages on ER/LAZ lighting globe style.
Condition: Placed in Improper Service
Action required: 16 - Rectify deficiencies w/in 14 days
Due 21 May 2025
Resolved 12 May 2025
03 - Water/Weathertight Conditions › N/A - No Subsystem › Cargo ports and other similar openings
Issued 7 May 2025 Resolved
Cover holes in deck where previous anchor lines traversed.
Condition: Placed in Improper Service
Action required: 16 - Rectify deficiencies w/in 14 days
Due 21 May 2025
Resolved 29 May 2025
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 7 May 2025 Resolved
Prove proper operation of engine room escape hatch.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 7 May 2025
Resolved 9 May 2025
09 - Working and Living Conditions › 092 - Working Conditions › Fitness for duty - intoxication
Issued 22 May 2023 Resolved
Vessel has an oceans route and is required to have on board alcohol strips if it cannot return to port within two hours.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 22 June 2023
Resolved 8 June 2023
04 - Emergency Systems › N/A - No Subsystem › Water level indicator
Issued 22 May 2023 Resolved
Forepeak H/W alarm inop.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 22 June 2023
Resolved 22 May 2023
Resolution: Fixed during inspection.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 22 May 2023 Resolved
Label bilge manifold.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 22 June 2023
Resolved 8 June 2023
11 - Life Saving Appliances › N/A - No Subsystem › Rigid liferafts
Issued 22 May 2023 Resolved
Lines on the liferafts were starting to fray. Issued requirement to install new lines.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 22 June 2023
Resolved 8 June 2023
05 - Radio Communications › N/A - No Subsystem › VHF radio installation
Issued 22 May 2023 Resolved
Vessel required to have MMSI & lat/long installed on one radio for distress. Vessel has two VHF radios. One had MMSI, one had lat/long. Required vessel to have one radio with both.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 22 June 2023
Resolved 22 May 2023
Resolution: Fixed during inspection.
04 - Emergency Systems › N/A - No Subsystem › Public address system
Issued 22 May 2023 Resolved
Vessel required to conduct safety drills prior to getting underway with pax. Vessel master admitted they did not. Required same.
Condition: Placed in Improper Service
Action required: 701 - Prior to carriage of passengers/cargo
Due 22 May 2023
Resolved 22 May 2023
07 - Fire Safety › N/A - No Subsystem › Remote Means of control (opening,pumps,ventilation,etc.) Machinery spaces
Issued 22 May 2023 Resolved
Emergency fuel shut off was not labeled.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 22 June 2023
Resolved 8 June 2023
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 22 May 2023 Resolved
Vessel had exposed light bulb in laz. Required to be covered.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 22 June 2023
Resolved 8 June 2023
07 - Fire Safety › N/A - No Subsystem › Crew alarm
Issued 22 May 2023 Resolved
Vessel has an oceans route and is required to install interconnected smoke detectors.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 22 June 2023
Resolved 8 June 2023
04 - Emergency Systems › N/A - No Subsystem › Functionality of Safety Systems
Issued 22 May 2023 Resolved
Vessels bilge manifold valve shutoff for forepeak was broken.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 22 June 2023
Resolved 8 June 2023
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 22 May 2023 Resolved
Vessels forepeak bilge suction would drain to the level of the pipe but no further leaving approx 3-4 feet of water in bilge. Issued requirement to troubleshoot and repair.
Action required: 701 - Prior to carriage of passengers/cargo
Due 22 June 2023
Resolved 23 May 2023
Resolution: Vessel discover a small pinhole leak in next compartment, so that the bilge line sucked air at a certain point and could not suck water.
09 - Working and Living Conditions › 092 - Working Conditions › Warning notices
Issued 26 April 2022 Resolved
Mark upper deck capacity.
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 10 May 2022
Resolved 26 April 2022
Resolution: Corrected on the spot.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 7 May 2021 Resolved
Condemned 8 kapok type PFDs after testing and hearing air escaping from internal bladders. Reduced PAX count by 8 until replaced.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 7 May 2021
Resolved 14 May 2021
Resolution: RCVD receipt of newly purchased type 1 PFDs and pictures of new PFDs marked and on board.
09 - Working and Living Conditions › 092 - Working Conditions › Other (accident prevention)
Issued 7 May 2021 Resolved
Identified diffuser missing on ER light.
Condition: Damaged By Earlier Event
Action required: 16 - Rectify deficiencies w/in 14 days
Due 21 May 2021
Resolved 12 May 2021
Resolution: Diffuser replaced.
07 - Fire Safety › N/A - No Subsystem › Fire pumps and its pipes
Issued 7 May 2021 Resolved
vessel's primary fire pump produced low volume and pressure when energized. O/O stated the pressure was suffucient. Required either display proper pressure or prove proper operation using Pitot tube to prove flow. O/O Identified the pump was not wired properly. re-wired and corrected deficiency prior to my departure.
Action required: 17 - Rectify deficiencies prior to departure
Due 7 May 2021
Resolved 7 May 2021
Resolution: Pump re-wired and tested with greater than 60 GPM and 50 PSI.
11 - Life Saving Appliances › N/A - No Subsystem › Stowage and provision of liferafts
Issued 27 May 2020 Resolved
Max number of persons each life float is designed for must clearly marked. Max persons allowed was worn and not legible. re-stencil Life Float max persons.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 10 June 2020
Resolved 26 June 2020
Resolution: Recieved photos of life floats re labled
11 - Life Saving Appliances › N/A - No Subsystem › Operational readiness of lifesaving appliances
Issued 27 May 2020 Resolved
ALL floating electric water lights were equipped with the wrong 9V battery. This included 4 life floats and 1 type IV throwable life ring. Vessel rep. provided proof of purchase of new batteries prior to departure and will send proof the batteries are installed.
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 10 June 2020
Resolved 3 June 2020
Resolution: Recieved photo evidence of the right battery installed and reciept of purchases
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 27 May 2020 Resolved
Re-label bilge pumping manifold valves.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 10 June 2020
Resolved 27 May 2020
Resolution: Corrected after I had left the inspection observed via face time call
09 - Working and Living Conditions › 091 - Living Conditions › Electrical devices
Issued 27 May 2020 Resolved
clean up loose wiring and dead end wires in and on top of the pilot house. Install switch on wires where where it is required or necessary to disable desired speaker equipment.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 26 June 2020
Resolved 26 June 2020
Resolution: Recieved photos of the overhead and pilot house wiring corrected
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 27 May 2020 Resolved
Install life jacket lights on each life jacket carried on board. Light must meet requirements of 46 CFR 161.012.
Condition: Placed in Improper Service
Action required: 50 - Rectify deficiencies w/in 30 days
Due 26 June 2020
Resolved 26 June 2020
Resolution: Recieved reciept of lights purchased.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 9 March 2020 Resolved
Replace cutlass bearing in intermediate struts
Condition: Damaged By Earlier Event
Action required: 50 - Rectify deficiencies w/in 30 days
Due 9 March 2020
Resolved 17 April 2020
Resolution: Def cleared with photo evidence/re-current visits to boat yard.
02 - Structural Conditions › N/A - No Subsystem › Hull - cracking
Issued 9 March 2020 Resolved
Crop and renew to good metal hole found in hull starboard side of step chine.
Condition: Damaged By Earlier Event
Action required: 50 - Rectify deficiencies w/in 30 days
Due 9 March 2020
Resolved 17 April 2020
Resolution: Def cleared with photo evidence/re-current visits to boat yard.
02 - Structural Conditions › N/A - No Subsystem › Hull damage impairing seaworthiness
Issued 9 March 2020 Resolved
Repair broken hand rail port side on main deck.
Condition: Damaged By Earlier Event
Action required: 50 - Rectify deficiencies w/in 30 days
Due 9 March 2020
Resolved 17 April 2020
Resolution: Def cleared with photo evidence/re-current visits to boat yard.
02 - Structural Conditions › N/A - No Subsystem › Bulkheads - cracking
Issued 9 March 2020 Resolved
Repair/replace bulk head penetration in #1 Void in aft bulkhead starboard side where PVC section penetrates hull. Penetration found to not be watertight with free communication around pipe.
Condition: Damaged By Earlier Event
Action required: 50 - Rectify deficiencies w/in 30 days
Due 9 March 2020
Resolved 17 April 2020
Resolution: Def cleared with photo evidence/re-current visits to boat yard.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 9 March 2020 Resolved
Repair hydraulic line supports in #1 void.
Condition: Damaged By Earlier Event
Action required: 50 - Rectify deficiencies w/in 30 days
Due 9 March 2020
Resolved 17 April 2020
Resolution: Def cleared with photo evidence/re-current visits to boat yard.
02 - Structural Conditions › N/A - No Subsystem › Hull - corrosion
Issued 9 March 2020 Resolved
Prepare keel for further inspection. Since Keel is not capable of being inspected via air pressure test, keel must be opened for further inspection. Repair keel as necessary.
Condition: Damaged By Earlier Event
Action required: 50 - Rectify deficiencies w/in 30 days
Due 9 March 2020
Resolved 17 April 2020
Resolution: Def cleared with photo evidence/re-current visits to boat yard.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Manholes/flush scuttles
Issued 9 March 2020 Resolved
Repair cracked seating surface for lazarette hatch cover.
Condition: Damaged By Earlier Event
Action required: 50 - Rectify deficiencies w/in 30 days
Due 9 March 2020
Resolved 17 April 2020
Resolution: Def cleared with photo evidence/re-current visits to boat yard.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 3 October 2019 Resolved
Found an approved type coupling, however there was a piece of rubber under the coupling where the coupling was acting as a soft patch for the bilge piping system. Make piping available for inspection at next dry dock exam.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 11 March 2020
Resolved 26 June 2020
Resolution: Coupling replaced with an approved type.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 3 October 2019 Resolved
Due to deficiencies found related to overnight commondations, Vessel Rep. stated he does not carry overnight passengers and requested to have the endorsement on the COI removed. New COI has been routed to remove overnight accom. onboard
Condition: Placed in Improper Service
Action required: 701 - Prior to carriage of passengers/cargo
Due 3 October 2019
Resolved 28 May 2020
Resolution: Drafted new COI with 0 over night accommodations.
04 - Emergency Systems › N/A - No Subsystem › Functionality of Safety Systems
Issued 29 March 2019 Resolved
Emergency Instructions must be posted at the operating station, providing actions to be taken in the event of fire, heavy weather, or man overboard. 46 CFR 185.510 & 46 CFR 185.512 46 CFR 185.25-1
Condition: Placed in Improper Service
Action required: 50 - Rectify deficiencies w/in 30 days
Due 29 April 2019
Resolved 10 July 2019
10 - Safety of Navigation › N/A - No Subsystem › Nautical publications
Issued 29 March 2019 Resolved
Provide onboard up-to-date U.S. Coast Pilot,Coast Guard Light List, Tide Tables, and Current Tables. Extracts from these publications for areas to be transited may be provided instead of the complete publication. 46 CFR 184.420
Action required: 50 - Rectify deficiencies w/in 30 days
Due 29 April 2019
Resolved 10 July 2019
Lifesaving › Lifejacket/PFD (Type III) › Quantity
Issued 6 April 2016 Resolved
One additional Child size life jacket needed.
Condition: Damaged By Earlier Event
Action required: 705 - Other - as specified
Due 25 April 2016
Resolved 6 April 2016
Resolution: Purchased new life jacket
Lifesaving › Lifebuoys › Self-igniting Lights
Issued 6 April 2016 Resolved
Float light attached to life ring must have a detachable clip
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 25 April 2016
Resolved 6 April 2016
Resolution: attached clip to float light line
Lifesaving › Lifebuoys › Markings (ship name/port)
Issued 6 April 2016 Resolved
Mark life ring, fire axe, and life floats with vessels name.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 6 April 2016
Resolved 6 April 2016
Resolution: Marked items as neeeded.
Lifesaving › Lifefloat › Floating Electric Waterlight
Issued 6 April 2016 Resolved
Replace batteries in float lights as needed.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 25 April 2016
Resolved 6 April 2016
Resolution: All float lights are working.

Casualty record · 1

4 April 2024Routine · role: Involved in a Marine Casualty · activity 7895337
Each line is an incident investigation the Coast Guard recorded with this hull among the vessels involved, with the date and the classification the Coast Guard gave it. Involvement is not fault. The investigation narrative is not published. Source: IIR, through 2026.

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.