MAURY USCG vessel records Sign in
← All vessels

FALCON 100

FALCON 100 is a 1974 mobile offshore drilling unit. The Coast Guard has recorded 40 inspections since 1982, most recently in February 2007, along with 84 deficiencies and 2 casualty investigations between 2006 and 2007.

Records from 1982 to 2007. Most recent: inspection, 28 February 2007.

Built
1974
Last inspected
28 February 2007
Documentation
Not in the documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

8755625 View on MarineTraffic leaves Maury; a third-party site, nothing from it is stored here
Flag
MARSHALL ISLANDS
—
Maury page id
psix-48138

Inspections, by type

…with no type recorded17
Years with a record 16 calendar years (1982–2007)
The 40 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

This record may be incomplete: the most recent inspection recorded for this vessel was 19 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Offshore class in Maury's sources begin in 1978.

Documentation record

Tonnage as PSIX records it9824 - Regulatory (Subpart C or D), Gross Ton
9274 - Regulatory (Subpart C or D), Net Ton
This hull's Official Number is not in the NVDC file dated 10 September 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.

Radio station licence

WDBTMMSI not assigned · expired · compulsorily equipped · granted 14 March 1985, cancelled 14 March 1990 · licensed under a name not among this hull’s recorded names (not shown)
FCC Universal Licensing System ship-station file of 6 September 2026, matched to this hull on its US Official Number. Status and dates are the file’s own. The licensee is not read from the file and is not shown. A lapsed licence’s MMSI is still the number the vessel transmitted under while it was valid.

Inspection history · 40

28 February 2007 Type not recorded
No type recorded · Marine Safety Unit Port Arthur · USCG Heartland District (CGD-H) · Activity 2879577
29 January 2007 COC-MODU Renew
Type not classified · Marine Safety Unit Port Arthur · USCG Heartland District (CGD-H) · Activity 2826507
1 March 2006 COC-MODU Annual
Type not classified · Marine Safety Unit Port Arthur · USCG Heartland District (CGD-H) · Activity 2585119
31 January 2005 COC-MODU Renew
Type not classified · MSO Mobile · USCG Heartland District (CGD-H) · Activity 2284463
29 December 2003 Administrative Inspection
Administrative · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1970980
8 January 2003 Administrative Inspection
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1727768
2 December 2002 Type not recorded
No type recorded · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1713280
20 October 2002 Type not recorded
No type recorded · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1713203
16 September 2002 Certificate of Compliance
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1680031
4 September 2002 Administrative Inspection
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1670648
6 November 2001 Deficiency Check
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 772029
1 October 2001 Deficiency Check
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1073818
19 September 2001 Letter of Compliance (Initial/Renewal)
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1435280
8 September 2001 Administrative
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1073277
20 September 2000 Letter of Compliance (Initial/Renewal)
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1471590
23 August 2000 Administrative
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1052636
4 November 1999 Administrative
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 799909
21 September 1999 Letter of Compliance (Initial/Renewal)
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1424808
19 September 1997 Type not recorded
No type recorded · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 775101
10 September 1997 Type not recorded
No type recorded · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 35781
16 February 1988 Administrative
Administrative · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1332638
28 August 1987 Administrative
Administrative · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1004930
29 May 1987 Type not recorded
No type recorded · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1027471
20 April 1987 Type not recorded
No type recorded · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1006008
17 March 1987 Administrative
Administrative · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1020224
12 January 1987 COI Inspection · Deficiency Check
Physical examination · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1017927
15 July 1986 Deficiency Check
Physical examination · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 992513
15 July 1986 Deficiency Check
Physical examination · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1306091
5 March 1986 Re-Inspection
Physical examination · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 999250
27 September 1985 Credit Drydock
Administrative · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 1299606
29 April 1985 Type not recorded
No type recorded · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 979376
3 December 1984 Type not recorded
No type recorded · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 975429
3 December 1984 Type not recorded
No type recorded · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 977718
1 June 1984 Type not recorded
No type recorded · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1282121
7 February 1984 Type not recorded
No type recorded · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 972918
14 July 1983 Type not recorded
No type recorded · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 968278
22 April 1983 Type not recorded
No type recorded · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 1283822
7 February 1983 Type not recorded
No type recorded · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1272213
10 January 1983 Type not recorded
No type recorded · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1272270
2 December 1982 Type not recorded
No type recorded · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 969740

Deficiency record · 84

Fire Fighting
Issued 19 September 2001 Resolved
RENEW MUD PIT DOORS. BOTH DOORS ARE WASETED/CORRODED.
Condition: Unknown
Due 19 September 2001
Resolved 19 September 2001
Documentation
Issued 19 September 2001 Resolved
PROVIDE POPERLY LICENSED PERSONNEL TO COMPLY WITH MARSHALL ISLANDS SAFE MANNING CERTIFICATE OR PROVIDE EQUIVALENCIES FROM FLAG STATE, OR NEW SAFE MANNING CERTIFICATE.
Condition: Unknown
Due 19 September 2001
Resolved 21 September 2001
Deck/Cargo
Issued 19 September 2001 Resolved
INSTALL PROPER PRESSURE RELIEF VALVE ON BULK AIR DRYER AIR RECEIVER FOR BULK TANKS NOT TO EXCEED MAWP OF TANK.
Condition: Unknown
Due 3 October 2001
Resolved 1 October 2001
Lifesaving
Issued 19 September 2001 Resolved
LOCATE SOURCE OF EXHAUST LEAK IN LIFEBOAT #1 AND PROPERLY REPAIR.
Condition: Unknown
Due 17 October 2001
Resolved 17 October 2001
Accommodation/Occupational Safety
Issued 19 September 2001 Resolved
DEGREASE DUCTING AND INSTALL PROPER FILTER/SCREENS IN GALLEY HOOD. REPLACE EXTINGUISHED LIGHT BULBS IN HOOD.
Condition: Unknown
Due 19 October 2001
Resolved 1 October 2001
Deck/Cargo
Issued 19 September 2001 Resolved
INSTALL PROPER PRESSURE RELIEF VALVES ON ALL DRY BULK TANKS (3 BARITE, 3 CEMENT). CURRENT RELIEF VALVES AT 44PSI. MAWP OF TANKS 40PSI.
Condition: Unknown
Due 19 September 2001
Resolved 21 September 2001
Lifesaving
Issued 19 September 2001 Resolved
PROPERLY INSTALL FALL PROTECTIVE DEVICES AS NECESSARY CAAISSON #2,#5.
Condition: Unknown
Due 19 October 2001
Resolved 4 October 2001
Lifesaving
Issued 20 September 2000 Resolved
INSTALL ADDITIONAL GENERAL ALARM SPEAKERS / AMPLIFIERS AS PLANNED. ENSURE ADEQUATE COVERAGE OF UPS.
Condition: Unknown
Due 20 October 2000
Resolved 24 October 2000
Electrical
Issued 20 September 2000 Resolved
COMPLETE INSTALLATION OF FIXED CO2 SYSTEM FOR PAINT LOCKER. REWIRE LIGHTS AND EXHAUST FAN WITH CLASS 1 DIVISION 1 FIXTURES, WIRE EXHAUST FAN THROUGH CO2 SYSTEM PRESSURE SWITCH.
Condition: Unknown
Due 27 September 2000
Resolved 27 September 2000
Lifesaving
Issued 21 September 1999 Resolved
IMPLEMENT TRAINING FOR REGULARLY ASSIGNED CREW & INDUSTRIAL PERSONNEL PER 46CFR109.213, RECORD AND MAINTIAN DOCUMENTATION.
Condition: Unknown
Due 3 November 1999
Resolved 3 November 1999
Documentation
Issued 21 September 1999 Resolved
PROVIDE DOCUMENTATION PROVING COAST GUARD APPROVAL OR FLAG STATE APPROVAL FROM MANUFACTURER OF FIBERGLASS GRATING USED IN MUD PITS.
Condition: Unknown
Due 21 September 1999
Resolved 21 September 1999
Navigation
Issued 21 September 1999 Resolved
REPAIR AND TEST FOGHORN AND OBSTRUCTION LIGHTS TO OPERATE AT CORRECT INTERVALS, RESPECTIVELY. SUBMIT TECHNICIAL REPORT TO [name withheld], OR TO SATISGACTION OF [name withheld].
Condition: Unknown
Due 3 November 1999
Resolved 3 November 1999
Lifesaving
Issued 21 September 1999 Resolved
PROVIDE FLAG STATE EXEMPTION FOR THE CARRIAGE OF IMMERSION SUITS. SUBMIT DOCUMENTATION TO [name withheld].
Condition: Unknown
Due 3 November 1999
Resolved 3 November 1999
Lifesaving
Issued 21 September 1999 Resolved
PROVIDE FOOD RATION FOR TOTAL CAPACITY OF EACH LIFEBOAT (10,000KJ/PERSON)._x001C__x001C_
Condition: Unknown
Due 3 November 1999
Resolved 3 November 1999
Engineering
Issued 21 September 1999 Resolved
PROVIDE FLAME BOWLS AND PLUG BOTTOM DRAINS ON RACOR FILTERS FOR EMERGENCY GENERATOR.
Condition: Unknown
Due 3 November 1999
Resolved 3 November 1999
Electrical
Issued 21 September 1999 Resolved
PROVIDE ADEQUATE LIGHTING FOR STAIRS IN CAISSONS #2 & #5.
Condition: Unknown
Due 3 November 1999
Resolved 3 November 1999
Electrical
Issued 20 April 1987 Resolved
PROPERLY SECURE ELECTRICAL CABLES IN MOON POOL AREA AND ON PORT CRANE PEDESTAL.
Condition: Unknown
Due 20 April 1987
Resolved 20 April 1987
Construction/Loadline
Issued 20 April 1987 Resolved
RENEW WEATHER TIGHT DOOR LEADING INTO THE MECHANICS SHOP, PORT SIDE.
Condition: Unknown
Due 20 April 1987
Resolved 20 April 1987
Fire Fighting
Issued 12 January 1987 Resolved
OBTAIN INTERNATIONAL OIL POLLUTION PREVENTION CERTIFICATE (IOPP) FOR RIG
Condition: Unknown
Due 12 January 1987
Resolved 12 January 1987
Accommodation/Occupational Safety
Issued 12 January 1987 Resolved
RENEW WEATHER TIGHT DOORS LEADING INTO THE MECHANICS SHOP,PORT SIDE, AND INTO CHANGE ROOM, STBD SIDE.
Condition: Unknown
Due 12 January 1987
Resolved 12 January 1987
Engineering
Issued 12 January 1987 Resolved
TEST OVERSPEED TRIP, HIGH ENGINE TEMP ALARM, AND LOW LUBE OIL ALARM FOR EMERGENCY GENRATOR IN PRESENCE OF COAST GUARD
Condition: Unknown
Due 12 January 1987
Resolved 12 January 1987
Accommodation/Occupational Safety
Issued 12 January 1987 Resolved
PROVIDE THIRTEEN(13) RELIEF VALVES FOR TENSIONER BOTTLES.
Condition: Unknown
Due 12 January 1987
Resolved 12 January 1987
Engineering
Issued 12 January 1987 Resolved
MAKE OPERABLE #3 EMD DIESEL ENGINE "HOT ENGINE" ALARM LIGHT
Condition: Unknown
Due 12 January 1987
Resolved 12 January 1987
Engineering
Issued 12 January 1987 Resolved
RENEW FLEX EXPANSION JOINTS IN WAY OF HEATER EXCHANGER ON FOLLOWING EMD DIESEL ENGINES: #1 (PORT SIDE) & #2 (STB SIDE)
Condition: Unknown
Due 12 January 1987
Resolved 12 January 1987
Electrical
Issued 12 January 1987 Resolved
MAKE PROPER ELECTICAL CONNECTIONS TO WELDING MACHINES (2) LOCATED IN MUD PUMP ROOM.
Condition: Unknown
Due 12 January 1987
Resolved 12 January 1987
Electrical
Issued 12 January 1987 Resolved
REMOVE ALL PLASTIC ELECTRICAL CABLE TIE WRAPS ON DRILL FLOOR AND REPLACE WITH METAL TIE WRAPS AT LEAST 1/2 INCH WIDE.
Condition: Unknown
Due 12 January 1987
Resolved 12 January 1987
Electrical
Issued 12 January 1987 Resolved
RENEW ALL BROKEN AND WASTED ELECTRICAL CABLE SUPPORTS, PORT SIDE, DRILL FLOOR.
Condition: Unknown
Due 12 January 1987
Resolved 12 January 1987
Navigation
Issued 12 January 1987 Resolved
MAKE RIG'S FOG HORN OPERABLE
Condition: Unknown
Due 12 January 1987
Resolved 12 January 1987
Electrical
Issued 12 January 1987 Resolved
PROPERLY MOUNT ELECTRICAL JUNCTION BOX FOR PA AND PHONE SYSTEM, LOCATED ON OUTSIDE BULKHEAD OF ROMEY ROOM, NEAR LIFEBOAT #2
Condition: Unknown
Due 12 January 1987
Resolved 12 January 1987
Electrical
Issued 12 January 1987 Resolved
PROPERLY SECURE ELECTRICAL CABLES IN CEMENT RM, MOON POOL AREA,FOR PORT STERN OBSTRUCTION LIGHT AND ON PORT CRANE PEDESTAL. PLASTIC TIE WRAPS NOT TO BE USEDL STAINLESS TIES MUST BE AT LEAST 1/2" WIDE. CABLES TO BE SECUREDAT INTERVALS LENGTHS OF NOT MORE THAN 18".
Condition: Unknown
Due 12 January 1987
Resolved 12 January 1987
Electrical
Issued 12 January 1987 Resolved
REMOUNT EXPLOSION PROOF LIGHT IN WAY OF MIDDLE OVERHEAD AND MAKE OPERABLE EXTINGUISHED EXPLOSION PROOF LIGHTS IN MUD PIT ROOM.
Condition: Unknown
Due 12 January 1987
Resolved 12 January 1987
Documentation
Issued 12 January 1987 Resolved
RIG'S MANNIG TO BE MAINTAINED PER COI(I.E., 4LIFEBOAT MAN) OR SUBMIT PROPOSAL FOR REDUCED MANNIG TO COAST GUARD TO COVER INSTANCES WHEN RIG IS IN A STACKED CONDITION.
Condition: Unknown
Due 12 January 1987
Resolved 12 January 1987
Documentation
Issued 12 January 1987 Resolved
CREATE AN OIL TRANSFER PROCEDURES PLAN, PER 33CFR 155.740 AND MAINTAIN ON BOARD RIG.
Condition: Unknown
Due 12 January 1987
Resolved 12 January 1987
Lifesaving
Issued 12 January 1987 Resolved
BOTH LIFEBOATS TO BE OPERATED IN THE WATER, 46CFR109.217
Condition: Unknown
Due 12 January 1987
Resolved 12 January 1987
Lifesaving
Issued 12 January 1987 Resolved
LIFEBOATS ARE TO BE LOWERED WEEKLY AND ENGINES RUN WEEKLY.
Condition: Unknown
Due 12 January 1987
Resolved 12 January 1987
Lifesaving
Issued 12 January 1987 Resolved
NO.1 LIFEBOAT (BOW) (A) PROPERLY SUPPORT LIMIT SWITCH ELECTRICAL CABLE, BOW(B) PROVIDE ADDITIONAL 15 QUARTS OF DRINKING WATER(REMOVED EXPIRED CANNED WATER (C) PROVIDE ADDITIONAL B-I FIRE EXTINGUISHER.
Condition: Unknown
Due 12 January 1987
Resolved 12 January 1987
Fire Fighting
Issued 12 January 1987 Resolved
PROVIDE COPY OF FOAM ANALYSIS REPORT FO HELO DECK FOAM SYSTEM
Condition: Unknown
Due 12 January 1987
Resolved 12 January 1987
Fire Fighting
Issued 12 January 1987 Resolved
PROVIDE ONBOARD TWO OPERABLE (AND UL ORFM APPROVED) OXYGEN/COMBUSTIBLE GAS METERS 46 CFR 108.497
Condition: Unknown
Due 12 January 1987
Resolved 12 January 1987
Lifesaving
Issued 15 July 1986 Resolved
FORWARD AND AFTER FALLS ARE TO BE REPLACED FOR #1 AND #2 LIFEBOATS.
Condition: Unknown
Due 15 July 1986
Resolved 15 July 1986
Lifesaving
Issued 15 July 1986 Resolved
UPON REPAIRS BEING COMPLETED TO THE #1 LIFEBOAT AND DAVIT SYSTEM, AND PRIOR TO USE, A COAST GUARD INSPECTOR SHALL WITNESS A WEIGHT TEST.
Condition: Unknown
Due 15 July 1986
Resolved 15 July 1986
Lifesaving
Issued 15 July 1986 Resolved
UPON REPAIRS BEING COMPLETED TO THE #1 LIFEBOAT AND DAVIT SYSTEM, AND PRIOR TO USE, A COAST GUARD INSPECTOR SHALL WITNESS A WEIGHT TEST OF THE LIFEBOAT AND DAVITS.
Condition: Unknown
Due 15 July 1986
Resolved 15 July 1986
Lifesaving
Issued 15 July 1986 Resolved
FORWARD AND AFTER FALLS ARE TO BE REPLACED FOR #1 AND #2 LIFEBOATS.
Condition: Unknown
Due 15 July 1986
Resolved 15 July 1986
Lifesaving
Issued 5 March 1986 Resolved
PROVIDE FOLLOWING SUPPLIES FOR #2 LIFEBOAT: 1 BUCKET, ROWLICKS.
Condition: Unknown
Due 5 March 1986
Resolved 5 March 1986
Fire Fighting
Issued 5 March 1986 Resolved
TAG VALVES AND PROVIDE INST. FOR FOAM SYSTEM.
Condition: Unknown
Due 5 March 1986
Resolved 5 March 1986
Construction/Loadline
Issued 5 March 1986 Resolved
PERMANENTLY MARK OFFICAL NUMBER ON MAIN BEAM.
Condition: Unknown
Due 5 March 1986
Resolved 5 March 1986
Fire Fighting
Issued 5 March 1986 Resolved
REMOVE NON-CG APPROVED PORTABLE FIRE EXTINGUISHERS AND PROPERLY SECURED ALLSPACES.
Condition: Unknown
Due 5 March 1986
Resolved 5 March 1986
Engineering
Issued 5 March 1986 Resolved
REPAIR LEAK OF PORT STERN TUBE PACKING GLAND.
Condition: Unknown
Due 5 March 1986
Resolved 5 March 1986
Lifesaving
Issued 5 March 1986 Resolved
PROVIDE FOLLOWING SUPPLIES FOR #1 LIFEBOAT: 1 BOATHOOK, 1 BUCKET,2 ROWLICKS
Condition: Unknown
Due 5 March 1986
Resolved 5 March 1986
Deck/Cargo
Issued 5 March 1986 Resolved
REPAIR OR REPLACE LUBE OIL TRANSFER PUMP.
Condition: Unknown
Due 5 March 1986
Resolved 5 March 1986
Fire Fighting
Issued 5 March 1986 Resolved
REPLACE LENS & BUTTON TO FIRE DETECTION STATION IN HALLIBURTON ROOM.
Condition: Unknown
Due 5 March 1986
Resolved 5 March 1986
Fire Fighting
Issued 5 March 1986 Resolved
PROVIDE 2 CAPS FOR GALLEY FIRE SYSTEM ON STOVES.
Condition: Unknown
Due 5 March 1986
Resolved 5 March 1986
Navigation
Issued 5 March 1986 Resolved
PROVIDE BELL
Condition: Unknown
Due 5 March 1986
Resolved 5 March 1986
Fire Fighting
Issued 5 March 1986 Resolved
PROVIDE INSTRUCTIONS FOR WATER SPRINKLER SYSTEM FOR QUARTERS.
Condition: Unknown
Due 5 March 1986
Resolved 5 March 1986
Navigation
Issued 5 March 1986 Resolved
REPAIR AFT ANCHOR LIGHT.
Condition: Unknown
Due 5 March 1986
Resolved 5 March 1986
Lifesaving
Issued 5 March 1986 Resolved
PROVIDE 12 PARACHUTE FLARES FOR PILOT HOUSE.
Condition: Unknown
Due 5 March 1986
Resolved 5 March 1986
Construction/Loadline
Issued 5 March 1986 Resolved
PAINT LOAD LINE.
Condition: Unknown
Due 5 March 1986
Resolved 5 March 1986
Unknown
Issued 3 December 1984 Resolved
THE FOLLOWING DEFICIENCY PERTAIN TO THE VESSEL, WESTERN PACESETTER III, DN560108 AND IS TO BE COMPLIED WITH BY 15MAR85.
Condition: Unknown
Due 3 December 1984
Resolved 3 December 1984
Lifesaving
Issued 7 February 1984 Resolved
MAKE PERMANENT REPAIRS TO LIFEBOAT NUMBER ONE (1) IN WAY OF THE DAMAGE TO THE STEM. 46CFR107.231(B)
Condition: Unknown
Due 7 February 1984
Resolved 7 February 1984
Unknown
Issued 7 February 1984 Resolved
THE FOLLOWING DEFICIENCY PERTAIN TO THE MODU WESTERN PACESETTER III, DN560108
Condition: Unknown
Due 7 February 1984
Resolved 7 February 1984
Accommodation/Occupational Safety
Issued 2 December 1982 Resolved
REPLACE 9 P-TANK RELIEF VALVES WITH MAXIMUM 40 PSI OF ADEQUATE SIZE TO RELIEVE VOLUME. VALVES TO BE FITTED WITH HAND RELIEVING GEAR.
Condition: Unknown
Due 2 January 1983
Resolved 2 December 1982
Accommodation/Occupational Safety
Issued 2 December 1982 Resolved
REPLACE RELIEF VALVE ON AIR RECEIVER IN MUD PUMP ROOM, MAXIMUM 165 PSI, WITH HAND RELIEVING GEAR.
Condition: Unknown
Due 2 January 1983
Resolved 2 December 1982
Deck/Cargo
Issued 2 December 1982 Resolved
MAKE MUD PUMP RELIEF VALVES AVAILABLE FOR TEST.
Condition: Unknown
Due 2 January 1983
Resolved 2 December 1982
Electrical
Issued 2 December 1982 Resolved
PROVIDE GLOBES AND GUARDS ON ALL LIGHTS WHERE MISSING.
Condition: Unknown
Due 2 December 1982
Resolved 2 December 1982
Electrical
Issued 2 December 1982 Resolved
REPAIR LIGHT SWITCH AT STARBOARD CHANGE ROOM DOOR.
Condition: Unknown
Due 2 January 1983
Resolved 2 December 1982
Electrical
Issued 2 December 1982 Resolved
REPAIR OR REPLACE, AS REQUIRED, ALL BUNK LIGHTS.
Condition: Unknown
Due 2 January 1983
Resolved 2 December 1982
Accommodation/Occupational Safety
Issued 2 December 1982 Resolved
REPLACE HEATER STRIPS IN GALLEY SERVING LINE WITH PROPER ELEMENTS.
Condition: Unknown
Due 2 January 1983
Resolved 2 December 1982
Engineering
Issued 2 December 1982 Resolved
REPLACE INSULATION ON ALL STEAM HEATER PIPING OR PROVIDE GUARDS AROUND PIPES.
Condition: Unknown
Due 2 January 1983
Resolved 2 December 1982
Electrical
Issued 2 December 1982 Resolved
REPLACE BATTERIES IN EMERGENCY LANTERNS IN STARBOARD PUMP ROOM ACCESS AND #6 CAISSON.
Condition: Unknown
Due 2 January 1983
Resolved 2 December 1982
Construction/Loadline
Issued 2 December 1982 Resolved
REPAIR DOGS ON ALL WATERTIGHT DOORS FOR PROPER OPERATION.
Condition: Unknown
Due 2 December 1982
Resolved 2 December 1982
Electrical
Issued 2 December 1982 Resolved
REPLACE LEAD LINING IN RADIO BATTERY BOX, SERVICE ALL BATTERIES AND MARK BOXES TO INDICATE USE.
Condition: Unknown
Due 2 January 1983
Resolved 2 December 1982
Construction/Loadline
Issued 2 December 1982 Resolved
REPAIR THE FOLLOWING INDICATORS ON BALLAST CONTROL PANEL: VMI4P, V2P, VMI3PVMI2P, VMI8P, VMIS, VM3S, VM7S, VM5S, VMI6S, VMI9S, VI9P, BALLAST PUMP 1S.
Condition: Unknown
Due 2 January 1983
Resolved 2 December 1982
Construction/Loadline
Issued 2 December 1982 Resolved
REPAIR THE FOLLOWING VALVES IN PUMP ROOMS: VM6P, VMI3P, VMI4S, VM6S, VMI5S.
Condition: Unknown
Due 2 January 1983
Resolved 2 December 1982
Documentation
Issued 2 December 1982 Resolved
DESIGNATE ALTERNATE PERSONS-IN-CHARGE IN WRITING.
Condition: Unknown
Due 2 December 1982
Resolved 2 December 1982
Documentation
Issued 2 December 1982 Resolved
HAVE ANNUAL LOAD LINE SURVEY CONDUCTED BY AMERICAN BUREAU OF SHIPPING.
Condition: Unknown
Due 2 January 1983
Resolved 2 December 1982
Documentation
Issued 2 December 1982 Resolved
SUBMIT FIRE CONTROL AND HAZARDOUS LOCATIONS PLAN TO [name withheld] FOR APPROVAL.
Condition: Unknown
Due 2 January 1983
Resolved 2 December 1982
Documentation
Issued 2 December 1982 Resolved
REVISE AND POST STATION BILL TO COMPLY WITH 46 CFR 109.501-109.505.
Condition: Unknown
Due 2 December 1982
Resolved 2 December 1982
Documentation
Issued 2 December 1982 Resolved
PROVIDE RIG WITH APPROVED CONSTRUCTION PORTFOLIO.
Condition: Unknown
Due 2 December 1982
Resolved 2 December 1982
Lifesaving
Issued 2 December 1982 Resolved
HAVE ALL HYDROSTATIC RELEASES FOR LIFERAFTS SERVICED AND TESTED.
Condition: Unknown
Due 2 December 1982
Resolved 2 December 1982
Lifesaving
Issued 2 December 1982 Resolved
PROVIDE ONE (1) SERVICE LINE FOR LINE THROWING GUN.
Condition: Unknown
Due 2 January 1983
Resolved 2 December 1982
Lifesaving
Issued 2 December 1982 Resolved
PROVIDE THE FOLLOWING FOR LIFEBOATS: #1-TABLE OF LIFESAVING SIGNALS. CLEAN BOTH BOATS.
Condition: Unknown
Due 2 January 1983
Resolved 2 December 1982
Fire Fighting
Issued 2 December 1982 Resolved
PROVIDE LOW VELOCITY SPRAY APPLICATORS AT FIRE STATIONS #1 AND #2 FOR HELIPORT AND 25 FOR DOWELL UNIT.
Condition: Unknown
Due 2 January 1983
Resolved 2 December 1982
Fire Fighting
Issued 2 December 1982 Resolved
HAVE PAINT LOCKER 50LB EXTINGUISHER, AND HAND PORTABLE CO2 FIRE EXTINGUISH-ERS, NOT TESTED WITHIN PAST 12 YEARS, HYDROSTATICALLY TESTED.
Condition: Unknown
Due 2 December 1982
Resolved 2 December 1982
Fire Fighting
Issued 2 December 1982 Resolved
MAKE PERMANENT REPAIRS TO FIRE MAIN BOOST PUMP SUCTION AND DISCHARGE LINES,IN ENGINE ROOM WHERE DOUBLER PLATES ARE FITTED.
Condition: Unknown
Due 2 January 1983
Resolved 2 December 1982
Fire Fighting
Issued 2 December 1982 Resolved
REPLACE ALL MISSING AND DISCONNECTED SPUD CHAINS ON ALL PURPOSE NOZZLES.
Condition: Unknown
Due 2 January 1983
Resolved 2 December 1982

Casualty record · 2

16 November 2006Routine · role: Involved in a Marine Casualty · activity 2830769
28 February 2007Routine · role: Involved in a Marine Casualty · serious marine incident, as classified · 2 injured · activity 2879577
Each line is an incident investigation the Coast Guard recorded with this hull among the vessels involved, with the date and the classification the Coast Guard gave it, and the bridge, lock or dam the investigation names where it names one. Involvement is not fault. The investigation narrative is not published. Source: IIR, through 2026.

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.