← All vessels
FALCON 100
FALCON 100 is a 1974 mobile offshore drilling unit. The Coast Guard has recorded 40 inspections since 1982, most recently in February 2007, along with 84 deficiencies and 2 casualty investigations between 2006 and 2007.
Records from 1982 to 2007. Most recent: inspection, 28 February 2007.
- Built
- 1974
- Last inspected
- 28 February 2007
- Documentation
- Not in the documentation file of 10 September 2026
- Deficiencies
- 84 recorded · 0 without a recorded resolution
- Controls
- None recorded without a removal date
- Casualties
- 2 investigations · 2006–2007
Identity
560108
8755625 View on MarineTraffic leaves Maury; a third-party site, nothing from it is stored here
WDBT
48138
Flag
MARSHALL ISLANDS
—
Maury page id
psix-48138
Inspections, by type
…with no type recorded17
Years with a record
16 calendar years (1982–2007)
The 40 inspections in the strip above, split by the kind of activity the US
Coast Guard recorded. Years with a record are calendar years in which a record exists, not
years in service. What Maury does not do.
This record may be incomplete: the most recent inspection recorded for this vessel was 19 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Offshore class in Maury's sources begin in 1978.
Documentation record
Tonnage as PSIX records it9824 - Regulatory (Subpart C or D), Gross Ton
9274 - Regulatory (Subpart C or D), Net Ton
9274 - Regulatory (Subpart C or D), Net Ton
This hull's Official Number is not in the NVDC file dated 10 September 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.
Radio station licence
WDBTMMSI not assigned · expired · compulsorily equipped · granted 14 March 1985, cancelled 14 March 1990 · licensed under a name not among this hull’s recorded names (not shown)
FCC Universal Licensing System ship-station file of 6 September 2026, matched to this hull on its
US Official Number. Status and dates are the file’s own. The licensee is not read from the file and is not shown.
A lapsed licence’s MMSI is still the number the vessel transmitted under while it was valid.
Inspection history · 40
28 February 2007
Type not recorded
No type recorded · Marine Safety Unit Port Arthur · USCG Heartland District (CGD-H) · Activity 2879577
29 January 2007
COC-MODU Renew
Type not classified · Marine Safety Unit Port Arthur · USCG Heartland District (CGD-H) · Activity 2826507
1 March 2006
COC-MODU Annual
Type not classified · Marine Safety Unit Port Arthur · USCG Heartland District (CGD-H) · Activity 2585119
31 January 2005
COC-MODU Renew
Type not classified · MSO Mobile · USCG Heartland District (CGD-H) · Activity 2284463
29 December 2003
Administrative Inspection
Administrative · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1970980
8 January 2003
Administrative Inspection
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1727768
2 December 2002
Type not recorded
No type recorded · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1713280
20 October 2002
Type not recorded
No type recorded · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1713203
16 September 2002
Certificate of Compliance
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1680031
4 September 2002
Administrative Inspection
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1670648
6 November 2001
Deficiency Check
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 772029
1 October 2001
Deficiency Check
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1073818
19 September 2001
Letter of Compliance (Initial/Renewal)
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1435280
8 September 2001
Administrative
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1073277
20 September 2000
Letter of Compliance (Initial/Renewal)
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1471590
23 August 2000
Administrative
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1052636
4 November 1999
Administrative
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 799909
21 September 1999
Letter of Compliance (Initial/Renewal)
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1424808
19 September 1997
Type not recorded
No type recorded · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 775101
10 September 1997
Type not recorded
No type recorded · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 35781
16 February 1988
Administrative
Administrative · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1332638
28 August 1987
Administrative
Administrative · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1004930
29 May 1987
Type not recorded
No type recorded · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1027471
20 April 1987
Type not recorded
No type recorded · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1006008
17 March 1987
Administrative
Administrative · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1020224
12 January 1987
COI Inspection · Deficiency Check
Physical examination · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1017927
15 July 1986
Deficiency Check
Physical examination · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 992513
15 July 1986
Deficiency Check
Physical examination · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1306091
5 March 1986
Re-Inspection
Physical examination · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 999250
27 September 1985
Credit Drydock
Administrative · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 1299606
29 April 1985
Type not recorded
No type recorded · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 979376
3 December 1984
Type not recorded
No type recorded · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 975429
3 December 1984
Type not recorded
No type recorded · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 977718
1 June 1984
Type not recorded
No type recorded · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1282121
7 February 1984
Type not recorded
No type recorded · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 972918
14 July 1983
Type not recorded
No type recorded · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 968278
22 April 1983
Type not recorded
No type recorded · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 1283822
7 February 1983
Type not recorded
No type recorded · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1272213
10 January 1983
Type not recorded
No type recorded · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1272270
2 December 1982
Type not recorded
No type recorded · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 969740
Deficiency record · 84
Fire Fighting
Issued 19 September 2001
Resolved
RENEW MUD PIT DOORS. BOTH DOORS ARE WASETED/CORRODED.
Documentation
Issued 19 September 2001
Resolved
PROVIDE POPERLY LICENSED PERSONNEL TO COMPLY WITH MARSHALL ISLANDS SAFE MANNING CERTIFICATE OR PROVIDE EQUIVALENCIES FROM FLAG STATE, OR NEW SAFE MANNING CERTIFICATE.
Deck/Cargo
Issued 19 September 2001
Resolved
INSTALL PROPER PRESSURE RELIEF VALVE ON BULK AIR DRYER AIR RECEIVER FOR BULK TANKS NOT TO EXCEED MAWP OF TANK.
Lifesaving
Issued 19 September 2001
Resolved
LOCATE SOURCE OF EXHAUST LEAK IN LIFEBOAT #1 AND PROPERLY REPAIR.
Accommodation/Occupational Safety
Issued 19 September 2001
Resolved
DEGREASE DUCTING AND INSTALL PROPER FILTER/SCREENS IN GALLEY HOOD. REPLACE EXTINGUISHED LIGHT BULBS IN HOOD.
Deck/Cargo
Issued 19 September 2001
Resolved
INSTALL PROPER PRESSURE RELIEF VALVES ON ALL DRY BULK TANKS (3 BARITE, 3 CEMENT). CURRENT RELIEF VALVES AT 44PSI. MAWP OF TANKS 40PSI.
Lifesaving
Issued 19 September 2001
Resolved
PROPERLY INSTALL FALL PROTECTIVE DEVICES AS NECESSARY CAAISSON #2,#5.
Lifesaving
Issued 20 September 2000
Resolved
INSTALL ADDITIONAL GENERAL ALARM SPEAKERS / AMPLIFIERS AS PLANNED. ENSURE ADEQUATE COVERAGE OF UPS.
Electrical
Issued 20 September 2000
Resolved
COMPLETE INSTALLATION OF FIXED CO2 SYSTEM FOR PAINT LOCKER. REWIRE LIGHTS AND EXHAUST FAN WITH CLASS 1 DIVISION 1 FIXTURES, WIRE EXHAUST FAN THROUGH CO2 SYSTEM PRESSURE SWITCH.
Lifesaving
Issued 21 September 1999
Resolved
IMPLEMENT TRAINING FOR REGULARLY ASSIGNED CREW & INDUSTRIAL PERSONNEL PER 46CFR109.213, RECORD AND MAINTIAN DOCUMENTATION.
Documentation
Issued 21 September 1999
Resolved
PROVIDE DOCUMENTATION PROVING COAST GUARD APPROVAL OR FLAG STATE APPROVAL FROM MANUFACTURER OF FIBERGLASS GRATING USED IN MUD PITS.
Navigation
Issued 21 September 1999
Resolved
REPAIR AND TEST FOGHORN AND OBSTRUCTION LIGHTS TO OPERATE AT CORRECT INTERVALS, RESPECTIVELY. SUBMIT TECHNICIAL REPORT TO [name withheld], OR TO SATISGACTION OF [name withheld].
Lifesaving
Issued 21 September 1999
Resolved
PROVIDE FLAG STATE EXEMPTION FOR THE CARRIAGE OF IMMERSION SUITS. SUBMIT DOCUMENTATION TO [name withheld].
Lifesaving
Issued 21 September 1999
Resolved
PROVIDE FOOD RATION FOR TOTAL CAPACITY OF EACH LIFEBOAT (10,000KJ/PERSON)._x001C__x001C_
Engineering
Issued 21 September 1999
Resolved
PROVIDE FLAME BOWLS AND PLUG BOTTOM DRAINS ON RACOR FILTERS FOR EMERGENCY GENERATOR.
Electrical
Issued 21 September 1999
Resolved
PROVIDE ADEQUATE LIGHTING FOR STAIRS IN CAISSONS #2 & #5.
Electrical
Issued 20 April 1987
Resolved
PROPERLY SECURE ELECTRICAL CABLES IN MOON POOL AREA AND ON PORT CRANE PEDESTAL.
Construction/Loadline
Issued 20 April 1987
Resolved
RENEW WEATHER TIGHT DOOR LEADING INTO THE MECHANICS SHOP, PORT SIDE.
Fire Fighting
Issued 12 January 1987
Resolved
OBTAIN INTERNATIONAL OIL POLLUTION PREVENTION CERTIFICATE (IOPP) FOR RIG
Accommodation/Occupational Safety
Issued 12 January 1987
Resolved
RENEW WEATHER TIGHT DOORS LEADING INTO THE MECHANICS SHOP,PORT SIDE, AND INTO CHANGE ROOM, STBD SIDE.
Engineering
Issued 12 January 1987
Resolved
TEST OVERSPEED TRIP, HIGH ENGINE TEMP ALARM, AND LOW LUBE OIL ALARM FOR EMERGENCY GENRATOR IN PRESENCE OF COAST GUARD
Accommodation/Occupational Safety
Issued 12 January 1987
Resolved
PROVIDE THIRTEEN(13) RELIEF VALVES FOR TENSIONER BOTTLES.
Engineering
Issued 12 January 1987
Resolved
MAKE OPERABLE #3 EMD DIESEL ENGINE "HOT ENGINE" ALARM LIGHT
Engineering
Issued 12 January 1987
Resolved
RENEW FLEX EXPANSION JOINTS IN WAY OF HEATER EXCHANGER ON FOLLOWING EMD DIESEL ENGINES: #1 (PORT SIDE) & #2 (STB SIDE)
Electrical
Issued 12 January 1987
Resolved
MAKE PROPER ELECTICAL CONNECTIONS TO WELDING MACHINES (2) LOCATED IN MUD PUMP ROOM.
Electrical
Issued 12 January 1987
Resolved
REMOVE ALL PLASTIC ELECTRICAL CABLE TIE WRAPS ON DRILL FLOOR AND REPLACE WITH METAL TIE WRAPS AT LEAST 1/2 INCH WIDE.
Electrical
Issued 12 January 1987
Resolved
RENEW ALL BROKEN AND WASTED ELECTRICAL CABLE SUPPORTS, PORT SIDE, DRILL FLOOR.
Navigation
Issued 12 January 1987
Resolved
MAKE RIG'S FOG HORN OPERABLE
Electrical
Issued 12 January 1987
Resolved
PROPERLY MOUNT ELECTRICAL JUNCTION BOX FOR PA AND PHONE SYSTEM, LOCATED ON OUTSIDE BULKHEAD OF ROMEY ROOM, NEAR LIFEBOAT #2
Electrical
Issued 12 January 1987
Resolved
PROPERLY SECURE ELECTRICAL CABLES IN CEMENT RM, MOON POOL AREA,FOR PORT STERN OBSTRUCTION LIGHT AND ON PORT CRANE PEDESTAL. PLASTIC TIE WRAPS NOT TO BE USEDL STAINLESS TIES MUST BE AT LEAST 1/2" WIDE. CABLES TO BE SECUREDAT INTERVALS LENGTHS OF NOT MORE THAN 18".
Electrical
Issued 12 January 1987
Resolved
REMOUNT EXPLOSION PROOF LIGHT IN WAY OF MIDDLE OVERHEAD AND MAKE OPERABLE EXTINGUISHED EXPLOSION PROOF LIGHTS IN MUD PIT ROOM.
Documentation
Issued 12 January 1987
Resolved
RIG'S MANNIG TO BE MAINTAINED PER COI(I.E., 4LIFEBOAT MAN) OR SUBMIT PROPOSAL FOR REDUCED MANNIG TO COAST GUARD TO COVER INSTANCES WHEN RIG IS IN A STACKED CONDITION.
Documentation
Issued 12 January 1987
Resolved
CREATE AN OIL TRANSFER PROCEDURES PLAN, PER 33CFR 155.740 AND MAINTAIN ON BOARD RIG.
Lifesaving
Issued 12 January 1987
Resolved
BOTH LIFEBOATS TO BE OPERATED IN THE WATER, 46CFR109.217
Lifesaving
Issued 12 January 1987
Resolved
LIFEBOATS ARE TO BE LOWERED WEEKLY AND ENGINES RUN WEEKLY.
Lifesaving
Issued 12 January 1987
Resolved
NO.1 LIFEBOAT (BOW) (A) PROPERLY SUPPORT LIMIT SWITCH ELECTRICAL CABLE, BOW(B) PROVIDE ADDITIONAL 15 QUARTS OF DRINKING WATER(REMOVED EXPIRED CANNED WATER (C) PROVIDE ADDITIONAL B-I FIRE EXTINGUISHER.
Fire Fighting
Issued 12 January 1987
Resolved
PROVIDE COPY OF FOAM ANALYSIS REPORT FO HELO DECK FOAM SYSTEM
Fire Fighting
Issued 12 January 1987
Resolved
PROVIDE ONBOARD TWO OPERABLE (AND UL ORFM APPROVED) OXYGEN/COMBUSTIBLE GAS METERS 46 CFR 108.497
Lifesaving
Issued 15 July 1986
Resolved
FORWARD AND AFTER FALLS ARE TO BE REPLACED FOR #1 AND #2 LIFEBOATS.
Lifesaving
Issued 15 July 1986
Resolved
UPON REPAIRS BEING COMPLETED TO THE #1 LIFEBOAT AND DAVIT SYSTEM, AND PRIOR TO USE, A COAST GUARD INSPECTOR SHALL WITNESS A WEIGHT TEST.
Lifesaving
Issued 15 July 1986
Resolved
UPON REPAIRS BEING COMPLETED TO THE #1 LIFEBOAT AND DAVIT SYSTEM, AND PRIOR TO USE, A COAST GUARD INSPECTOR SHALL WITNESS A WEIGHT TEST OF THE LIFEBOAT AND DAVITS.
Lifesaving
Issued 15 July 1986
Resolved
FORWARD AND AFTER FALLS ARE TO BE REPLACED FOR #1 AND #2 LIFEBOATS.
Lifesaving
Issued 5 March 1986
Resolved
PROVIDE FOLLOWING SUPPLIES FOR #2 LIFEBOAT: 1 BUCKET, ROWLICKS.
Fire Fighting
Issued 5 March 1986
Resolved
TAG VALVES AND PROVIDE INST. FOR FOAM SYSTEM.
Construction/Loadline
Issued 5 March 1986
Resolved
PERMANENTLY MARK OFFICAL NUMBER ON MAIN BEAM.
Fire Fighting
Issued 5 March 1986
Resolved
REMOVE NON-CG APPROVED PORTABLE FIRE EXTINGUISHERS AND PROPERLY SECURED ALLSPACES.
Engineering
Issued 5 March 1986
Resolved
REPAIR LEAK OF PORT STERN TUBE PACKING GLAND.
Lifesaving
Issued 5 March 1986
Resolved
PROVIDE FOLLOWING SUPPLIES FOR #1 LIFEBOAT: 1 BOATHOOK, 1 BUCKET,2 ROWLICKS
Deck/Cargo
Issued 5 March 1986
Resolved
REPAIR OR REPLACE LUBE OIL TRANSFER PUMP.
Fire Fighting
Issued 5 March 1986
Resolved
REPLACE LENS & BUTTON TO FIRE DETECTION STATION IN HALLIBURTON ROOM.
Fire Fighting
Issued 5 March 1986
Resolved
PROVIDE 2 CAPS FOR GALLEY FIRE SYSTEM ON STOVES.
Navigation
Issued 5 March 1986
Resolved
PROVIDE BELL
Fire Fighting
Issued 5 March 1986
Resolved
PROVIDE INSTRUCTIONS FOR WATER SPRINKLER SYSTEM FOR QUARTERS.
Navigation
Issued 5 March 1986
Resolved
REPAIR AFT ANCHOR LIGHT.
Lifesaving
Issued 5 March 1986
Resolved
PROVIDE 12 PARACHUTE FLARES FOR PILOT HOUSE.
Construction/Loadline
Issued 5 March 1986
Resolved
PAINT LOAD LINE.
Unknown
Issued 3 December 1984
Resolved
THE FOLLOWING DEFICIENCY PERTAIN TO THE VESSEL, WESTERN PACESETTER III, DN560108 AND IS TO BE COMPLIED WITH BY 15MAR85.
Lifesaving
Issued 7 February 1984
Resolved
MAKE PERMANENT REPAIRS TO LIFEBOAT NUMBER ONE (1) IN WAY OF THE DAMAGE TO THE STEM. 46CFR107.231(B)
Unknown
Issued 7 February 1984
Resolved
THE FOLLOWING DEFICIENCY PERTAIN TO THE MODU WESTERN PACESETTER III, DN560108
Accommodation/Occupational Safety
Issued 2 December 1982
Resolved
REPLACE 9 P-TANK RELIEF VALVES WITH MAXIMUM 40 PSI OF ADEQUATE SIZE TO RELIEVE VOLUME. VALVES TO BE FITTED WITH HAND RELIEVING GEAR.
Accommodation/Occupational Safety
Issued 2 December 1982
Resolved
REPLACE RELIEF VALVE ON AIR RECEIVER IN MUD PUMP ROOM, MAXIMUM 165 PSI, WITH HAND RELIEVING GEAR.
Deck/Cargo
Issued 2 December 1982
Resolved
MAKE MUD PUMP RELIEF VALVES AVAILABLE FOR TEST.
Electrical
Issued 2 December 1982
Resolved
PROVIDE GLOBES AND GUARDS ON ALL LIGHTS WHERE MISSING.
Electrical
Issued 2 December 1982
Resolved
REPAIR LIGHT SWITCH AT STARBOARD CHANGE ROOM DOOR.
Electrical
Issued 2 December 1982
Resolved
REPAIR OR REPLACE, AS REQUIRED, ALL BUNK LIGHTS.
Accommodation/Occupational Safety
Issued 2 December 1982
Resolved
REPLACE HEATER STRIPS IN GALLEY SERVING LINE WITH PROPER ELEMENTS.
Engineering
Issued 2 December 1982
Resolved
REPLACE INSULATION ON ALL STEAM HEATER PIPING OR PROVIDE GUARDS AROUND PIPES.
Electrical
Issued 2 December 1982
Resolved
REPLACE BATTERIES IN EMERGENCY LANTERNS IN STARBOARD PUMP ROOM ACCESS AND #6 CAISSON.
Construction/Loadline
Issued 2 December 1982
Resolved
REPAIR DOGS ON ALL WATERTIGHT DOORS FOR PROPER OPERATION.
Electrical
Issued 2 December 1982
Resolved
REPLACE LEAD LINING IN RADIO BATTERY BOX, SERVICE ALL BATTERIES AND MARK BOXES TO INDICATE USE.
Construction/Loadline
Issued 2 December 1982
Resolved
REPAIR THE FOLLOWING INDICATORS ON BALLAST CONTROL PANEL: VMI4P, V2P, VMI3PVMI2P, VMI8P, VMIS, VM3S, VM7S, VM5S, VMI6S, VMI9S, VI9P, BALLAST PUMP 1S.
Construction/Loadline
Issued 2 December 1982
Resolved
REPAIR THE FOLLOWING VALVES IN PUMP ROOMS: VM6P, VMI3P, VMI4S, VM6S, VMI5S.
Documentation
Issued 2 December 1982
Resolved
DESIGNATE ALTERNATE PERSONS-IN-CHARGE IN WRITING.
Documentation
Issued 2 December 1982
Resolved
HAVE ANNUAL LOAD LINE SURVEY CONDUCTED BY AMERICAN BUREAU OF SHIPPING.
Documentation
Issued 2 December 1982
Resolved
SUBMIT FIRE CONTROL AND HAZARDOUS LOCATIONS PLAN TO [name withheld] FOR APPROVAL.
Documentation
Issued 2 December 1982
Resolved
REVISE AND POST STATION BILL TO COMPLY WITH 46 CFR 109.501-109.505.
Documentation
Issued 2 December 1982
Resolved
PROVIDE RIG WITH APPROVED CONSTRUCTION PORTFOLIO.
Lifesaving
Issued 2 December 1982
Resolved
HAVE ALL HYDROSTATIC RELEASES FOR LIFERAFTS SERVICED AND TESTED.
Lifesaving
Issued 2 December 1982
Resolved
PROVIDE ONE (1) SERVICE LINE FOR LINE THROWING GUN.
Lifesaving
Issued 2 December 1982
Resolved
PROVIDE THE FOLLOWING FOR LIFEBOATS: #1-TABLE OF LIFESAVING SIGNALS. CLEAN BOTH BOATS.
Fire Fighting
Issued 2 December 1982
Resolved
PROVIDE LOW VELOCITY SPRAY APPLICATORS AT FIRE STATIONS #1 AND #2 FOR HELIPORT AND 25 FOR DOWELL UNIT.
Fire Fighting
Issued 2 December 1982
Resolved
HAVE PAINT LOCKER 50LB EXTINGUISHER, AND HAND PORTABLE CO2 FIRE EXTINGUISH-ERS, NOT TESTED WITHIN PAST 12 YEARS, HYDROSTATICALLY TESTED.
Fire Fighting
Issued 2 December 1982
Resolved
MAKE PERMANENT REPAIRS TO FIRE MAIN BOOST PUMP SUCTION AND DISCHARGE LINES,IN ENGINE ROOM WHERE DOUBLER PLATES ARE FITTED.
Fire Fighting
Issued 2 December 1982
Resolved
REPLACE ALL MISSING AND DISCONNECTED SPUD CHAINS ON ALL PURPOSE NOZZLES.
Casualty record · 2
16 November 2006Routine · role: Involved in a Marine Casualty · activity 2830769
28 February 2007Routine · role: Involved in a Marine Casualty · serious marine incident, as classified · 2 injured · activity 2879577
Each line is an incident investigation the Coast Guard recorded with this hull among the vessels involved, with the date and the classification the Coast Guard gave it, and the bridge, lock or dam the investigation names where it names one. Involvement is not fault. The investigation narrative is not published. Source: IIR, through 2026.
Ownership record
The Coast Guard's documentation record for this hull -- the Abstract of Title,
with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National
Vessel Documentation Center, files it here with its date, and every reader of this page gets it.