MAURY USCG vessel records Sign in
← All vessels

WRECK-REATION II

WRECK-REATION II is a 1974 passenger vessel (inspected). The Coast Guard has recorded 72 inspections since 1985, most recently in March 2026, along with 57 deficiencies and 3 casualty investigations between 2003 and 2022.

Records from 1985 to 2026. Most recent: inspection, 19 March 2026.

Built
1974
Last inspected
19 March 2026
Documentation
Valid · documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

WDL4254
Flag
UNITED STATES
368129690
Maury page id
psix-48141

Inspections, by type

…with no type recorded12
Years with a record 36 calendar years (1985–2026)
The 72 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Passenger Ship class in Maury's sources begin in 1977.

Documentation record

Registered dimensions (L × B × D)36.2 ft × 14.1 ft × 6.4 ft
Registered tonnagegross 17 / net 12
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
Builderbuilder not recorded · FORT WALTON BEACH, FL, UNITED STATES · built 1974
Hull materialFRP (Fiberglass)
PropulsionDiesel Reduction
Hull shapeNot recorded
Hull configurationNot recorded
Hailing portPANAMA CITY BEACH, FL
Trade endorsementsCoastwise, unrestricted
DocumentationValid · issued 21 August 2026 · expires 31 August 2027
Service, as the file records itPassenger (Inspected)
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it17 - Regulatory (Subpart C or D), Gross Ton
12 - Regulatory (Subpart C or D), Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 September 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.

Radio station licence

WDL4254MMSI 368129690 · active · compulsorily equipped · granted 28 January 2020, expires 28 January 2030
WDE8815MMSI 367409960 · expired · compulsorily equipped · granted 14 May 2009, cancelled 20 July 2019 · licensed under a name not among this hull’s recorded names (not shown)
WDA4633MMSI 366811530 · expired · compulsorily equipped · granted 16 May 2001, cancelled 16 July 2011 · licensed under a name not among this hull’s recorded names (not shown)
WCQ5426MMSI not assigned · expired · compulsorily equipped · granted 30 March 1995, cancelled 4 June 2005 · licensed under a name not among this hull’s recorded names (not shown)
WCP9820MMSI not assigned · expired · compulsorily equipped · granted 21 February 1995, cancelled 23 April 2005 · licensed under a name not among this hull’s recorded names (not shown)
FCC Universal Licensing System ship-station file of 6 September 2026, matched to this hull on its US Official Number. Status and dates are the file’s own. The licensee is not read from the file and is not shown. A lapsed licence’s MMSI is still the number the vessel transmitted under while it was valid.

Inspection history · 72

19 March 2026 Annual Inspection · Vessel Attendance · Administrative Inspection
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 8328603
22 December 2025 Internal Structural Exam · Administrative Inspection · Drydock Exam
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 8276952
21 January 2025 COI Inspection · Administrative Inspection
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 8063788
29 February 2024 Annual Inspection · Administrative Inspection
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 7872268
1 December 2023 Administrative Inspection · Internal Structural Exam · Drydock Exam
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 7832318
7 February 2023 Annual Inspection
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 7633380
13 May 2022 Type not recorded
No type recorded · Station Panama City · USCG Heartland District (CGD-H) · Activity 7454935
13 May 2022 Type not recorded
No type recorded · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 7489566
16 December 2021 Annual Inspection
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 7369305
9 December 2021 Internal Structural Exam · Drydock Exam
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 7365137
2 March 2021 DAPI Audit · Annual Inspection · Administrative Inspection
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 7149150
27 January 2020 Administrative Inspection · COI Inspection · DAPI Audit
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 6893384
11 December 2019 Administrative Inspection · Internal Structural Exam · Hull Examination
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 6875240
19 October 2018 Internal Structural Exam · Drydock Exam · Deficiency Check
Physical examination · Marine Safety Unit Lake Worth · USCG Southeast District (CGD-SE) · Activity 6564231
3 July 2018 Annual Inspection · DAPI Audit
Physical examination · Marine Safety Unit Lake Worth · USCG Southeast District (CGD-SE) · Activity 6465650
22 August 2017 DAPI Audit · Annual Inspection · Deficiency Check
Physical examination · Marine Safety Unit Lake Worth · USCG Southeast District (CGD-SE) · Activity 6248041
26 October 2016 Internal Structural Exam · Drydock Exam · Deficiency Check
Physical examination · Marine Safety Unit Lake Worth · USCG Southeast District (CGD-SE) · Activity 6029810
22 August 2016 Annual Inspection · DAPI Audit
Physical examination · Marine Safety Unit Lake Worth · USCG Southeast District (CGD-SE) · Activity 5982616
20 August 2015 DAPI Audit · Annual Inspection
Physical examination · Marine Safety Unit Lake Worth · USCG Southeast District (CGD-SE) · Activity 5225174
9 October 2014 Drydock Exam · Internal Structural Exam · Deficiency Check
Physical examination · Marine Safety Unit Lake Worth · USCG Southeast District (CGD-SE) · Activity 5001939
23 May 2014 DAPI Audit · Deficiency Check · COI Inspection
Physical examination · Marine Safety Unit Lake Worth · USCG Southeast District (CGD-SE) · Activity 4866019
10 August 2011 Deficiency Check · DAPI Audit · Annual Inspection
Physical examination · Marine Safety Unit Lake Worth · USCG Southeast District (CGD-SE) · Activity 4110085
23 November 2010 Internal Structural Exam · Drydock Exam
Physical examination · Marine Safety Unit Lake Worth · USCG Southeast District (CGD-SE) · Activity 3897423
21 October 2010 Annual Inspection
Physical examination · Marine Safety Unit Lake Worth · USCG Southeast District (CGD-SE) · Activity 3874196
14 May 2009 COI Inspection
Physical examination · Marine Safety Unit Lake Worth · USCG Southeast District (CGD-SE) · Activity 3474521
16 March 2009 Hull Examination
Physical examination · Marine Safety Unit Lake Worth · USCG Southeast District (CGD-SE) · Activity 3434011
10 March 2006 Hull Examination
Physical examination · Marine Safety Unit Lake Worth · USCG Southeast District (CGD-SE) · Activity 2599945
3 August 2005 COI Inspection
Physical examination · Marine Safety Unit Lake Worth · USCG Southeast District (CGD-SE) · Activity 2449900
25 May 2004 Deficiency Check
Physical examination · Marine Safety Unit Lake Worth · USCG Southeast District (CGD-SE) · Activity 2077450
23 April 2004 Annual Inspection
Physical examination · Marine Safety Unit Lake Worth · USCG Southeast District (CGD-SE) · Activity 2049405
6 March 2004 Type not recorded
No type recorded · Marine Safety Unit Lake Worth · USCG Southeast District (CGD-SE) · Activity 2023730
20 January 2004 Hull Examination
Physical examination · Marine Safety Unit Lake Worth · USCG Southeast District (CGD-SE) · Activity 1988265
30 December 2003 Type not recorded
No type recorded · Marine Safety Unit Lake Worth · USCG Southeast District (CGD-SE) · Activity 1981343
30 April 2003 Deficiency Check
Physical examination · Marine Safety Unit Lake Worth · USCG Southeast District (CGD-SE) · Activity 1783446
22 April 2003 Re-Inspection
Physical examination · Marine Safety Unit Lake Worth · USCG Southeast District (CGD-SE) · Activity 1778145
28 May 2002 Re-Inspection
Physical examination · Marine Safety Unit Lake Worth · USCG Southeast District (CGD-SE) · Activity 1621779
19 February 2002 Hull Examination
Physical examination · Marine Safety Unit Lake Worth · USCG Southeast District (CGD-SE) · Activity 1487265
13 July 2001 Administrative
Administrative · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1067894
29 May 2001 MARPOL Annex V Examination · COI Inspection
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1391622
5 September 2000 Deficiency Check
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 822552
6 April 2000 COI Inspection · Hull Examination
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1399343
5 April 2000 Administrative
Administrative · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 817591
5 April 2000 Type not recorded
No type recorded · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1049031
30 June 1999 MARPOL Annex V Examination · COI Inspection
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1369263
15 June 1999 Type not recorded
No type recorded · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 212677
11 June 1999 Type not recorded
No type recorded · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 212329
29 June 1998 MARPOL Annex V Examination · Re-Inspection
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 795108
13 March 1998 Deficiency Check
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1123974
10 March 1998 Hull Examination
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 785414
12 January 1998 Type not recorded
No type recorded · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 62595
17 July 1997 MARPOL Annex V Examination · Re-Inspection
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1117114
25 September 1996 Deficiency Check
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1140520
14 June 1996 MARPOL Annex V Examination · COI Inspection
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1089113
7 June 1996 Hull Examination
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1089467
28 August 1995 Administrative
Administrative · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 880959
29 July 1995 Type not recorded
No type recorded · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 64275
29 July 1995 Type not recorded
No type recorded · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 222609
13 March 1995 Hull Examination
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1167405
7 March 1995 Re-Inspection
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 846523
6 April 1994 Deficiency Check
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 858949
2 March 1994 Re-Inspection
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1164899
4 March 1993 Hull Examination · COI Inspection
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1149428
21 September 1990 Type not recorded
No type recorded · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1225584
27 June 1990 Re-Inspection
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1231730
24 May 1990 Hull Examination
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1240745
31 May 1989 Re-Inspection · Deficiency Check
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 892569
20 May 1988 Hull Examination · COI Inspection
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1040715
3 December 1987 Administrative
Administrative · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1027509
26 January 1987 Hull Examination
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1318162
12 August 1986 Deficiency Check · COI Inspection
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1320366
23 August 1985 Re-Inspection
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 989453
3 July 1985 Type not recorded
No type recorded · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1286490

Deficiency record · 57

03 - Water/Weathertight Conditions › N/A - No Subsystem › Railing, gangway, walkway and means for safe passage
Issued 26 October 2018 Resolved
Secure loose rails and decking on swim platform. 46 CFR 176.610
Action required: 705 - Other - as specified
Due 9 November 2018
Resolved 15 November 2018
Resolution: Rails and decking secured.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Railing, gangway, walkway and means for safe passage
Issued 26 October 2018 Resolved
Repair cracked shackle on swim platform chain. 46 CFR 176.610
Action required: 705 - Other - as specified
Due 9 November 2018
Resolved 15 November 2018
Resolution: Shackle replaced.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Railing, gangway, walkway and means for safe passage
Issued 26 October 2018 Resolved
Add 12 inch rail courses around top deck. 46 CFR 177.900(g)
Action required: 16 - Rectify deficiencies w/in 14 days
Due 9 November 2018
Resolved 15 November 2018
Resolution: Courses added.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 26 October 2018 Resolved
Add permanent type connectors at battery cable terminal connections. 46 CFR 183.350
Action required: 16 - Rectify deficiencies w/in 14 days
Due 9 November 2018
Resolved 15 November 2018
Resolution: Permanent type connectors installed.
Communications › Radio Communications › EPIRB
Issued 22 August 2017 Resolved
Provide new Epirb.
Action required: 705 - Other - as specified
Resolved 31 August 2017
Resolution: Provided new epirb in float free arrangement.
Accommodation/Occupational Safety › Medical/First Aid › Medicine Chest
Issued 22 August 2017 Resolved
Update expired medicines in first aid kit.
Action required: 705 - Other - as specified
Resolved 31 August 2017
Resolution: Updated medicines in first aid kit.
Lifesaving › Hand Flares › Quantity
Issued 22 August 2017 Resolved
Provide 1 additional approved hand flare.
Action required: 705 - Other - as specified
Resolved 31 August 2017
Resolution: Provided 1 additional hand flare.
Stability › Unintentional Flooding › General
Issued 26 October 2016 Resolved
Prove proper operation of STBD sink drain through hull valve.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 28 October 2016
Resolution: Owner renewed the valves.
Stability › Unintentional Flooding › General
Issued 26 October 2016 Resolved
Prove proper operation of port sink drain through hull valve.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 28 October 2016
Resolution: Owner renewed the port through hull valve.
Communications › Radio Communications › EPIRB
Issued 20 August 2015 Resolved
Provide new hydrostatic release for epirb.
Condition: Invalid
Action required: 705 - Other - as specified
Due 27 September 2015
Resolved 29 September 2015
Resolution: Owner provided new hydrostatic release.
Electrical › Electric Supply System (service) › Overcurrent Device
Issued 9 October 2014 Resolved
Install battery switches as per 46 CFR 183.320(i).
Due 28 January 2015
Resolved 28 January 2015
Resolution: Installed battery switches.
Electrical › Electric Supply System (service) › Battery Installation
Issued 23 May 2014 Resolved
Replace starting batteries.
Condition: Improper/Lack of Maintenance
Due 23 May 2014
Resolved 23 May 2014
Resolution: Replaced starting batteries.
Documentation › Safety/Response Plans/Programs › General Arrangement Plans
Issued 23 May 2014 Resolved
Original def from 21AUG2012 was closed in error, owner did submit new plans, approval letter was generated but never signed by the [name withheld] def.
Action required: 705 - Other - as specified
Due 30 September 2014
Resolved 22 September 2014
Resolution: approval letter signed by OCMI and sent to vessel
Lifesaving › Lifebuoys › Serviceable
Issued 11 August 2011 Resolved
Owner or Operator must replace or renew ring lifebuoy.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 18 August 2011
Resolved 12 August 2011
Resolution: Owner renewed ring lifebuoy.
Electrical › Electrical Distribution System (service) › Circuit Breaker
Issued 11 August 2011 Resolved
Owner or Operator must prove compliance with original approved electrical plans or submit updates to plans for approval.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 26 August 2011
Resolved 24 August 2011
Resolution: Owner submitted new electrical plans for review.
Communications › Radio Communications › EPIRB
Issued 10 August 2011 Resolved
Owner or Operator must replace or renew hydrostatic release for EPRIB.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 18 August 2011
Resolved 16 September 2011
Operations/Management › Drug and Alcohol Testing › EAP Training Requirements
Issued 10 August 2011 Resolved
Owner or Operator must prove compliance with EAP requirements.
Condition: Placed in Improper Service
Action required: 705 - Other - as specified
Due 18 August 2011
Resolved 24 August 2011
Resolution: Owner, Operator and crew are in compliance with EAP requirements.
Stability › Watertight Integrity › General
Issued 10 March 2006 Resolved
Provide plans to make all deck hatches watertight.
Condition: Placed in Improper Service
Action required: 705 - Other - as specified
Due 24 March 2006
Resolved 16 March 2009
Stability › Watertight Integrity › Coaming
Issued 10 March 2006 Resolved
Install sinch coaming on door leading to lower cabin.
Condition: Placed in Improper Service
Action required: 705 - Other - as specified
Due 24 March 2006
Resolved 16 March 2009
Stability › Watertight Integrity › General
Issued 10 March 2006 Resolved
Remove sluice valve from collision bulkhead and make all penetrations watertight.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 24 March 2006
Resolved 16 March 2009
Navigation › Collision/Grounding Avoidance › Navigation Lights
Issued 10 March 2006 Resolved
Remove all obstrutions from navigation lights and properly install diving at night nav lights.
Condition: Design Flaw
Action required: 705 - Other - as specified
Due 24 March 2006
Resolved 10 March 2006
Engineering › Steering Gear System › Hydraulic Hose
Issued 10 March 2006 Resolved
Remove unapproved hydraulic hose and install approved piping or hose.
Condition: Placed in Improper Service
Action required: 705 - Other - as specified
Due 24 March 2006
Resolved 16 March 2009
Electrical › Electrical Distribution System (service) › Wiring
Issued 10 March 2006 Resolved
Properly secure all loose wiring with approved hangers at intervals of not more than 24 inches.
Condition: Placed in Improper Service
Action required: 705 - Other - as specified
Due 24 March 2006
Resolved 16 March 2009
Construction/Loadline › Hull › Hull Plating
Issued 10 March 2006 Resolved
Properly grind out all areas indicated on hull and repair.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 24 March 2006
Resolved 16 March 2009
Construction/Loadline › Structures › Superstructure
Issued 10 March 2006 Resolved
Properly repair control station deck where wood is rotting and weak.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 24 March 2006
Resolved 16 March 2009
Documentation › Certificates/Documents
Issued 23 April 2004 Resolved
Provide current FCC Safety Radio Certificate
Action required: 705 - Other - as specified
Due 26 April 2004
Resolved 26 April 2004
Documentation › Logs/Records › Logbook (official)
Issued 23 April 2004 Resolved
Provide training log 46CFR185.420
Action required: 705 - Other - as specified
Due 23 May 2004
Resolved 25 May 2004
Documentation › Logs/Records › Logbook (official)
Issued 23 April 2004 Resolved
Provide EPIRB test log IAW 46CFR185.728(c)
Action required: 705 - Other - as specified
Due 23 May 2004
Resolved 25 May 2004
Documentation › Certificates/Documents › Certificate of Inspection
Issued 23 April 2004 Resolved
Provide current EPIRB registration 46CFR180.15(g)
Action required: 705 - Other - as specified
Due 23 May 2004
Resolved 25 May 2004
Engineering › Sea-water System (primary cooling) › Piping
Issued 23 April 2004 Resolved
Replace cracked raw water hose between sea strainer and stbd MDE.
Action required: 705 - Other - as specified
Due 23 May 2004
Resolved 25 May 2004
Engineering › Diesel Engine (propulsion-reduction gear) › Bedplate
Issued 23 April 2004 Resolved
Make permanent repairs to MDE motor mounts. LEGACY COMPONENT DESC: Motor mounts
Action required: 705 - Other - as specified
Due 23 May 2004
Resolved 25 May 2004
Construction/Loadline › Penetrations › Valve Flange
Issued 23 April 2004 Resolved
Provide metallic valves IWO forward water tight bulkhead, where MSD hose traverses.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 23 May 2004
Resolved 25 May 2004
Engineering › Steering Gear System › Fastener
Issued 23 April 2004 Resolved
Install locking devices on steering gear. 46CFR176.800
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 26 April 2004
Resolved 23 April 2004
Communications › Radio Communications
Issued 22 April 2003 Resolved
Renew Hydrostatic rekease for EPIRB. Vessel limited to 3 miles from shore. LEGACY COMPONENT DESC: EPIRB
Condition: Improper/Lack of Maintenance
Due 1 May 2003
Resolved 8 May 2003
Resolution: Cleared.
Accommodation/Occupational Safety › Occupational Safety
Issued 22 April 2003 Resolved
Provide guards for rotating machinery in engine space. LEGACY COMPONENT DESC: Guards for Exposed Hazards
Condition: Unknown
Due 1 May 2003
Resolved 30 April 2003
Engineering › Diesel Engine (propulsion-direct drive)
Issued 22 April 2003 Resolved
Repair exhaust leak to starboard exhaust leak. LEGACY COMPONENT DESC: Piping (exhaust)
Condition: Unknown
Due 1 May 2003
Resolved 30 April 2003
Construction/Loadline › Structures
Issued 22 April 2003 Resolved
Make deck watertight. LEGACY COMPONENT DESC: Deck Plating
Due 22 June 2003
Resolved 22 April 2003
Lifesaving
Issued 6 April 2000 Resolved
PROVE EPIRB BATTERY DATE. VSL RESTRICTED TO NOT MORE THAN 3 NM FROM SHORE UNTIL REQUIREMENT MET.
Condition: Unknown
Due 6 April 2000
Resolved 6 April 2000
Lifesaving
Issued 6 April 2000 Resolved
PROVIDE SECOND LIFEFLOAT TO MEET MINIMUM 50% CAPACITY. VESSEL RESTRICTED TO24 TOTAL PERSONS UNTIL REQUIREMENT MET.
Condition: Unknown
Due 6 April 2000
Resolved 6 April 2000
Documentation
Issued 6 April 2000 Resolved
PROVIDE COPY OF FCC OPERATOR'S PERMIT.
Condition: Unknown
Due 6 April 2000
Resolved 6 April 2000
Lifesaving
Issued 6 April 2000 Resolved
PROVIDE NEW BECKETS AND PAINTER FOR LIFE FLOAT AND CUT DOWN MOUNTING BRACKET "L" ARMS TO ENABLE FLOAT FREE CONDITION.
Condition: Unknown
Due 6 April 2000
Resolved 6 April 2000
Unknown
Issued 5 April 2000 Resolved
[withheld — contains personal information; the deficiency system, dates, and resolution status are shown above]
Condition: Unknown
Due 21 April 2000
Resolved 21 April 2000
Fire Fighting
Issued 10 March 1998 Resolved
PROVIDE 3 BII FIRE EXTINGUISHERS IAW COI
Condition: Unknown
Due 10 April 1998
Resolved 23 April 1998
Engineering
Issued 10 March 1998 Resolved
REPLACE FIRST SECTION OF HOSE FM T-HULL FITTING IWO STBD MDE.
Condition: Unknown
Due 10 April 1998
Resolved 23 April 1998
Accommodation/Occupational Safety
Issued 10 March 1998 Resolved
REPLACE ROTTED SECTIONS OF SECOND LONGITUDINAL UPPER DECK FRAME FM STBD IN LIKE QUALITY AND KIND.
Condition: Unknown
Due 10 May 1998
Resolved 23 April 1998
Documentation
Issued 14 June 1996 Resolved
PROVIDE A CURRENT FCC RADIOTELEPHONEY CERT. VESSEL IS RESTRICTED TO OPERATIONS WITHIN 1000 FEET FROM SHORE UNTIL THIS REQ. IS CLEARED.
Condition: Unknown
Due 14 July 1996
Resolved 5 August 1996
Electrical
Issued 14 June 1996 Resolved
PROVIDE ELECTRICAL PLANS FOR VESSEL FOR PLAN REVIEW.
Condition: Unknown
Due 25 September 1996
Resolved 25 September 1996
Fire Fighting
Issued 14 June 1996 Resolved
PROVIDE ONE (1) ADDITIONAL B-II EXTINGISHER FOR A TOTAL OF THREE (3) B-II'S
Condition: Unknown
Due 14 July 1996
Resolved 5 August 1996
Construction/Loadline
Issued 14 June 1996 Resolved
PROVIDE DRIP RAIL AND DRAINS FOR FORWARD HATCH IN MACHINERY SPACE.
Condition: Unknown
Due 14 July 1996
Resolved 5 August 1996
Construction/Loadline
Issued 14 June 1996 Resolved
PROVIDE HATCH WITH AT LEAST 6" COMBING, FOR ACCOMMODATION SPACE.
Condition: Unknown
Due 5 August 1996
Resolved 5 August 1996
Accommodation/Occupational Safety
Issued 14 June 1996 Resolved
PROVIDE RAIL HEIGHTS OF 36" FM DECK IN PASSENGER SPACE.
Condition: Unknown
Due 14 July 1996
Resolved 5 August 1996
Electrical
Issued 2 March 1994 Resolved
REMOVE OR PROPERLY TERMINATE TWO DEADENDED ELECT CABLES. ONE IN FORPEAK ANDONE IN MAIN CABIN PORT AFT NEAR STAIR.
Condition: Unknown
Due 2 March 1994
Resolved 2 March 1994
Documentation
Issued 2 March 1994 Resolved
SUBMIT WRITTEN PROOF OF A CHEMICAL TESTING PROGRAM WHICH COMPLIES WITH 46 CFR PART 16 TO MSO MIAMI.
Condition: Unknown
Due 2 March 1994
Resolved 2 March 1994
Fire Fighting
Issued 2 March 1994 Resolved
PROVIDE PROPER MARINE FIRE EXTINGUISHER BRACKET FOR BI.
Condition: Unknown
Due 2 March 1994
Resolved 2 March 1994
Documentation
Issued 2 March 1994 Resolved
PROVE THAT MASTER/OWNER HAS VALID FCC MARINE RADIO OPERATOR PERMIT.
Condition: Unknown
Due 2 March 1994
Resolved 2 March 1994
Lifesaving
Issued 2 March 1994 Resolved
REPLACE 20 INCH RING BUOY WITH REQUIRED 24 INCH RING BUOY.
Condition: Unknown
Due 2 March 1994
Resolved 2 March 1994
Navigation
Issued 2 March 1994 Resolved
PROVIDE PROPER SIZE SHIPS BELL.
Condition: Unknown
Due 2 March 1994
Resolved 2 March 1994

Casualty record · 3

30 December 2003Significant Marine Casualty · role: Involved in a Marine Casualty · serious marine incident, as classified · 1 dead · activity 1981343
6 March 2004Routine · role: Involved in a Marine Casualty · serious marine incident, as classified · 1 injured · activity 2023730
13 May 2022Routine · role: Involved in a Marine Casualty · 1 injured · activity 7489566
Each line is an incident investigation the Coast Guard recorded with this hull among the vessels involved, with the date and the classification the Coast Guard gave it, and the bridge, lock or dam the investigation names where it names one. Involvement is not fault. The investigation narrative is not published. Source: IIR, through 2026.

Recorded names · 1

SS MINNOW (2003–2004). Names as the Coast Guard recorded them in incident records, with the years they appear; some are renames and some are spelling variants.

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.