Records from 1982 to 2022. Most recent: inspection, 21 January 2022.
Inspection history · 111
21 January 2022
Deficiency Check
Physical examination · Marine Safety Unit Port Arthur · USCG Heartland District (CGD-H) · Activity 7387165
18 April 2008
Administrative Inspection
Administrative · Marine Safety Unit Port Arthur · USCG Heartland District (CGD-H) · Activity 3187248
10 July 2007
Type not recorded
No type recorded · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 3021760
23 May 2006
Annual Inspection
Physical examination · Marine Safety Unit Port Arthur · USCG Heartland District (CGD-H) · Activity 2617712
9 January 2006
Administrative Inspection
Administrative · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 2563621
25 August 2005
COI Inspection · Hull Examination
Physical examination · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 2472373
5 November 2003
Administrative Inspection
Administrative · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 1942673
17 April 2002
Periodic Inspection
Physical examination · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 1605888
26 August 2001
Administrative
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1073185
16 August 2001
Type not recorded
No type recorded · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 1387146
19 May 2001
Administrative
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1064028
15 March 2001
Hull Examination · Re-Inspection
Physical examination · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 1403372
8 March 2001
Type not recorded
No type recorded · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 209544
8 March 2001
Type not recorded
No type recorded · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 753858
24 February 2001
Type not recorded
No type recorded · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 69951
11 April 2000
COI Inspection
Physical examination · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 1444315
12 April 1999
Re-Inspection
Physical examination · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 1454656
11 March 1999
Type not recorded
No type recorded · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 754082
10 March 1999
Type not recorded
No type recorded · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 203407
13 January 1999
Type not recorded
No type recorded · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 1473359
29 December 1998
Hull Examination
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1378538
12 August 1998
Administrative
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1131644
9 July 1998
Deficiency Check
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1128397
14 April 1998
COI Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1383852
13 February 1998
Administrative
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 776727
29 December 1997
Administrative
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1117414
27 August 1997
Administrative
Administrative · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 1119800
15 April 1997
Re-Inspection
Physical examination · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1443866
24 September 1996
Administrative
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1138760
16 July 1996
Administrative
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1092151
10 July 1996
Type not recorded
No type recorded · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 18781
14 May 1996
Type not recorded
No type recorded · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 694911
8 May 1996
Type not recorded
No type recorded · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1083715
25 April 1996
COI Inspection · Hull Examination
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1357567
15 April 1996
Type not recorded
No type recorded · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 215011
28 March 1996
Administrative
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1077879
22 March 1996
Deficiency Check
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1077603
6 March 1996
Deficiency Check
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 885769
2 February 1996
Administrative
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1182125
31 January 1996
Deficiency Check
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 883358
18 January 1996
Administrative
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 875618
7 December 1995
Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1186183
29 September 1995
Type not recorded
No type recorded · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 150413
22 May 1995
Administrative
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1183681
11 May 1995
Deficiency Check
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 902315
17 April 1995
Re-Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1455256
27 April 1994
COI Inspection
Physical examination · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1354762
8 February 1994
Administrative
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1161988
1 February 1994
Administrative
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1162091
6 January 1994
Hull Examination
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1358256
17 December 1993
Administrative
Administrative · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 849004
16 November 1993
Administrative
Administrative · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 1146883
28 July 1993
Administrative
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 845119
7 July 1993
Deficiency Check
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1151403
18 May 1993
Re-Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1459010
13 May 1993
Type not recorded
No type recorded · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 839140
3 March 1993
Administrative
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1150089
23 December 1992
Deficiency Check
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1136972
13 October 1992
Administrative
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 954090
2 October 1992
Type not recorded
No type recorded · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 960064
20 September 1992
Type not recorded
No type recorded · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 97056
13 August 1992
Deficiency Check
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 947776
2 June 1992
COI Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1457058
11 June 1991
Re-Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1247641
23 April 1991
Deficiency Check
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 905970
27 February 1991
Deficiency Check · Hull Examination
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 921352
5 February 1991
Deficiency Check
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1304840
17 December 1990
Deficiency Check
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 907063
13 December 1990
Deficiency Check
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1304281
12 October 1990
Type not recorded
No type recorded · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 1237556
11 October 1990
Deficiency Check
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1229514
30 August 1990
Administrative
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1236571
7 August 1990
Drydock Extension
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1234435
21 June 1990
COI Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1240012
30 May 1990
Administrative
Administrative · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1227173
5 March 1990
Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1237691
25 October 1989
Deficiency Check
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1206654
7 September 1989
Deficiency Check
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1308762
20 July 1989
Re-Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1347449
2 February 1989
Type not recorded
No type recorded · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1196552
5 December 1988
Type not recorded
No type recorded · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 896174
15 September 1988
Deficiency Check
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1042859
12 September 1988
Deficiency Check
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1040425
2 August 1988
Hull Examination
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1350953
25 July 1988
Administrative
Administrative · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1339816
23 June 1988
COI Inspection
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1207703
25 September 1987
Administrative
Administrative · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1320005
3 August 1987
Administrative
Administrative · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1029555
23 July 1987
Deficiency Check
Physical examination · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1003436
27 May 1987
Re-Inspection
Physical examination · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1028180
22 April 1987
Administrative
Administrative · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1325206
1 October 1986
Deficiency Check
Physical examination · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1319667
4 August 1986
Deficiency Check
Physical examination · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1319828
3 July 1986
Type not recorded
No type recorded · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 998087
23 June 1986
COI Inspection · Credit Drydock
Physical examination · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 998667
1 May 1986
Deficiency Check
Physical examination · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1307966
2 April 1986
Damage Survey
Physical examination · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 997891
3 February 1986
Deficiency Check
Physical examination · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 997497
7 October 1985
Type not recorded
No type recorded · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1003240
23 September 1985
Type not recorded
No type recorded · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 999617
12 April 1985
Type not recorded
No type recorded · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 984456
15 January 1985
Type not recorded
No type recorded · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 974832
15 August 1984
Type not recorded
No type recorded · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1282398
11 April 1984
Type not recorded
No type recorded · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 972651
25 September 1983
Type not recorded
No type recorded · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1273675
20 June 1983
Type not recorded
No type recorded · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 969496
25 May 1983
Type not recorded
No type recorded · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 969981
7 March 1983
Type not recorded
No type recorded · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 969212
22 February 1983
Type not recorded
No type recorded · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 963884
12 January 1983
Type not recorded
No type recorded · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 964762
6 January 1982
Type not recorded
No type recorded · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 963571
Engineering
Issued 12 April 1999
Resolved
CONDUCT OPERATIONAL TEST OF ALL EMD'S IN PRESENCE OF ATTENDING MARINE INSPECTOR
Condition: Unknown
Due 12 April 1999
Resolved 12 April 1999
Lifesaving
Issued 12 April 1999
Resolved
CONDUCT OPERATIONAL TEST AND BREAK TEST TO BOTH LIFE BOATS INS PRESENTS OF MARINE INSPECTIOR.
Condition: Unknown
Due 12 April 1999
Resolved 12 April 1999
Fire Fighting
Issued 12 April 1999
Resolved
MAKE PERMINATE REPAIRS TO #1 FIREPUMP/SALT WATER PUMP HOUSING
Condition: Unknown
Due 12 April 1999
Resolved 12 April 1999
Fire Fighting
Issued 29 December 1998
Resolved
MAKE PERMANENT REPAIRS (GOUGE/REWELD OR CROP/RENEW) TO FIREMAIN PIPING WHERE HOLED IN PUMP ROOM TO COLUMN SC4 .
Condition: Unknown
Due 19 January 1999
Resolved 19 January 1999
Construction/Loadline
Issued 29 December 1998
Resolved
SUBMIT DIVE REPORT AND VIDEO OF UNDERWATER SWIM-BY TO [name withheld].
Condition: Unknown
Due 29 December 1998
Resolved 29 December 1998
Construction/Loadline
Issued 29 December 1998
Resolved
CONDUCT NDE OF COLUMN TO HULL CONNECTIONS, K-BRACE SUPPORTS, AND COLUMN TO TRANSVERSE MEMBERS TO THE SATISFACTION OF THE ATTENDING MARINE INSPECTOR. SUBMIT REPORT TO [name withheld].
Condition: Unknown
Due 29 December 1998
Resolved 29 December 1998
Electrical
Issued 29 December 1998
Resolved
REPLACE ALL WASTED ELECTRICAL WATERTIGHT STUFFING TUBES ON EACH LEVEL IN COLUMN SC4 AS NECESSARY. REMOVE AND PROPERLY SEAL ALL ELECTRICAL WIRING PENETRATIONS FROM DISMANTLED AUXILIARY PROPULSION AND STEERING SYSTEMS IN COLUMN SC4 AND PC4.
Condition: Unknown
Due 29 December 1998
Resolved 29 December 1998
Construction/Loadline
Issued 29 December 1998
Resolved
OPEN FOR INSPECTION PORT AND STARBOARD SEA VALVES AND PONTOON BALLAST TANKSTO THE SATISFACTION OF THE ATTENDING MARINE INSPECTOR.
Condition: Unknown
Due 29 December 1998
Resolved 29 December 1998
Lifesaving
Issued 14 April 1998
Resolved
Crop and renew, as original, liferaft davit embarkation deck angle supportswhere wasted.
Condition: Unknown
Due 24 April 1998
Resolved 24 April 1998
Lifesaving
Issued 14 April 1998
Resolved
Crop and renew fairlead brackets to wire falls, where wasted, on lifeboats one and two to satisfaction of attending marine inspector.
Condition: Unknown
Due 14 April 1998
Resolved 14 April 1998
Lifesaving
Issued 14 April 1998
Resolved
Repair as original, ten inch fracture at gunwhale, port-forward side of lifeboat number one.
Condition: Unknown
Due 14 April 1998
Resolved 14 April 1998
Electrical
Issued 14 April 1998
Resolved
Conduct satisfactory operational test of overspeed and low lube oil shutdowns, and reverse power relays on all three main generators. Test total rig emergency shutdown. Record in logbook.
Condition: Unknown
Due 24 April 1998
Resolved 24 April 1998
Lifesaving
Issued 14 April 1998
Resolved
Conduct operational test of lifeboat release gear under a load of 1.1 timesthe total mass of the boats when loaded with its full complement.
Condition: Unknown
Due 14 April 1998
Resolved 14 April 1998
Lifesaving
Issued 14 April 1998
Resolved
Gauge main girder of outboard davit A-frame supports, where wasted, along embarkation deck to lifeboat number one and two. Submit technician report to [name withheld] along with original thicknesses.
Condition: Unknown
Due 14 April 1998
Resolved 14 April 1998
Construction/Loadline
Issued 15 April 1997
Resolved
REPAIR DOOR AND HANDLE TO PASSAGEWAY DOOR ADJACENT TO "ON DUTY BATH" COMPARTMENT
Condition: Unknown
Due 15 May 1997
Resolved 19 May 1997
Construction/Loadline
Issued 15 April 1997
Resolved
MAKE TEMP REPAIR TO 10" SALT WATER LINE PRIOR TO 19APR97 AND PERMANENT REPAIR PRIOR TO NEXT TO NEXT RIG MOVE.
Condition: Unknown
Due 19 April 1997
Resolved 19 May 1997
Fire Fighting
Issued 15 April 1997
Resolved
CROP AND RENEW WASTED FIREMAIN PIPING
Condition: Unknown
Due 23 April 1997
Resolved 19 May 1997
Fire Fighting
Issued 15 April 1997
Resolved
GAUGE A REPRESENTATIVE SECTION OF FIRE MAIN IN EACH AREA OF THE RIG AND PROVIDE REPORT TO COAST GUARD WITH ORIGINAL THICKNESS OF PIPE.
Condition: Unknown
Due 15 May 1997
Resolved 11 June 1997
Lifesaving
Issued 15 April 1997
Resolved
REPAIR EYEWASH ON DRILL FLOOR AND PLACE DUST COVERS ON EYEWASH STATION IN MUD PIT AREA.
Condition: Unknown
Due 15 May 1997
Resolved 19 May 1997
Electrical
Issued 15 April 1997
Resolved
REPAIR LUBE OIL SHUTDOWN ON EMERGENCY GENERATOR.
Condition: Unknown
Due 15 May 1997
Resolved 19 May 1997
Engineering
Issued 15 April 1997
Resolved
REPLACE SIGHTGLASS ON FUEL OIL DAY TANK TO EMERGENCY GENERATOR WITH HEAT RESISTANT GLASS
Condition: Unknown
Due 15 May 1997
Resolved 19 May 1997
Construction/Loadline
Issued 15 April 1997
Resolved
REPAIR VENT DOGS ON STARBOARD CRANE SMALL PAINT LOCKER.
Condition: Unknown
Due 15 May 1997
Resolved 19 May 1997
Fire Fighting
Issued 15 April 1997
Resolved
PROVIDE PROPER LABELING FOR VENT CLOSURE ACTIONS AND INDICATOR FOR STARBOARD CRANE LARGE PAINT LOCKER.
Condition: Unknown
Due 15 May 1997
Resolved 19 May 1997
Lifesaving
Issued 15 April 1997
Resolved
PROVIDE ONE SMOKE SIGNAL FOR LIFEBOAT #1.
Condition: Unknown
Due 15 May 1997
Resolved 19 May 1997
Lifesaving
Issued 22 March 1996
Resolved
PROVIDE GASTIGHT, SELF-CLOSING DOORS, POSITIVE VENTILATION, AND LOSS OF VENTILATION ALARMS FOR EACH COMPARTMENT WITH ACCESS TO MUDPIT AREA OR CELLAR DECK AS SHOWN ON HAZARDOUS AREA PLAN AND REQUIRED BY_x001C_ 46 CFR 111.105-33(f)(3).
Condition: Unknown
Due 22 March 1996
Resolved 22 March 1996
Lifesaving
Issued 7 December 1995
Resolved
MAKE PERMANENT REPAIRS TO WASTED LIFEBOAT PLATFORM SUPPORT TUBE ON STBD SIDE OF FWD LIFEBOAT PLATFORM (HOLES WASTED IN TUBULAR).
Condition: Unknown
Due 5 January 1996
Resolved 5 January 1996
Accommodation/Occupational Safety
Issued 7 December 1995
Resolved
PROVIDE GASTIGHT, SELF-CLOSING DOORS, POSITIVE PRESSURE VENTILATION, AND LOSS OF VENTILATION ALARMS FOR EACH COMPARTMENT WITH ACCESS TO MUDPIT AREA OR CELLAR DECK AS SHOWN ON HAZARDOUS AREA PLAN AND REQUIRED BY 46 CFR 111.105-33(f)(3).
Condition: Unknown
Due 7 December 1995
Resolved 7 December 1995
Documentation
Issued 7 December 1995
Resolved
MAKE CORRECTIONS TO FIRE FIGHTING AND EMERGENCY EQUIPMENT ARRANGEMENT PLAN TO INCLUDE NEW QUARTERS INSTALLATION AND LIFEBOAT UPGRADES AND SUBMIT TO MSO NEW ORLEANS FOR REVIEW AND APPROVAL.
Condition: Unknown
Due 7 December 1995
Resolved 7 December 1995
Lifesaving
Issued 7 December 1995
Resolved
REMARK LIFEBOATS WITH CAPACITY OF 64 VICE OLD CAPACITY OF 50. MARK SEATING DIRECTION ARROWS IN BOTH LIFEBOATS.
Condition: Unknown
Due 5 January 1996
Resolved 5 January 1996
Lifesaving
Issued 7 December 1995
Resolved
REMOVE RUST SCALE FROM SUPPORT TUBE FOR STBD DAVIT ARM ON AFT LIFEBOAT AND PROVIDE GUAGINGS OF PITTED AREAS AND ORIGINAL THICKNESS READINGS FOR REVIEW.
Condition: Unknown
Due 5 January 1996
Resolved 5 January 1996
Electrical
Issued 17 April 1995
Resolved
PROPERLY STRAP CONDUCTORS ON DRILL FLOOR, SHALE SHAKER AND MUD PIT AREAS.
Condition: Unknown
Due 17 April 1995
Resolved 17 April 1995
Electrical
Issued 17 April 1995
Resolved
REMOVE OR MAKE PERMANENT EXTENSION CORD FROM RECEPTACLE TO J-BOX ON DRILL FLOOR.
Condition: Unknown
Due 28 April 1995
Resolved 28 April 1995
Electrical
Issued 17 April 1995
Resolved
REMOVE WELDING LEAD CONNECTION OR PROVIDE EXPLOSION PROOF TYPE ON DRILL FLOOR.
Condition: Unknown
Due 28 April 1995
Resolved 28 April 1995
Engineering
Issued 17 April 1995
Resolved
REPAIR AS NECESSARY GOVERNOR TO GENSET #3.
Condition: Unknown
Due 28 April 1995
Resolved 28 April 1995
Electrical
Issued 17 April 1995
Resolved
REMOVE TIME DELAY ON PURGE LOSS ALARM ON DRILLERS CONSOLE.
Condition: Unknown
Due 28 April 1995
Resolved 28 April 1995
Electrical
Issued 17 April 1995
Resolved
PROVIDE COVERS FOR SWITCH BOX BY DAY TANK IN MOTOR ROOM AND GAITRONICS BOX OVER FUEL CENTRIFUGE IN MOTOR ROOM.
Condition: Unknown
Due 28 April 1995
Resolved 28 April 1995
Lifesaving
Issued 27 April 1994
Resolved
CONDUCT WEIGHT TEST OF #2 LIFE BOAT.
Condition: Unknown
Due 27 April 1994
Resolved 27 April 1994
Construction/Loadline
Issued 18 May 1993
Resolved
REPAIR W/T DOOR ON FWD BLKHD SACK ROOM DOOR AS NECESSARY.
Condition: Unknown
Due 18 May 1993
Resolved 18 May 1993
Accommodation/Occupational Safety
Issued 2 October 1992
Resolved
REPAIR PITS IN BULK TANKS 5, 6, AND 7. SUBMIT REPAIR PROPOSAL TO MSO MORGAN CITY._x001C_ _x001C_ _x001C_
Condition: Unknown
Due 2 October 1992
Resolved 2 October 1992
Engineering
Issued 13 August 1992
Resolved
GUAGE PITS ON STARBOARD BULK TANKS (#5-8).
Condition: Unknown
Due 13 August 1992
Resolved 13 August 1992
Engineering
Issued 13 August 1992
Resolved
HYDRO. FUEL TRANSFER HOSE.
Condition: Unknown
Due 13 August 1992
Resolved 13 August 1992
Construction/Loadline
Issued 2 June 1992
Resolved
TEST ALL COAST GUARD INSPECTED PRESSURE RELIEF VALVES.
Condition: Unknown
Due 2 June 1992
Resolved 2 June 1992
Lifesaving
Issued 21 June 1990
Resolved
PROVIDE A TOTAL OF TWELVE RED PARACHUTE FLARES FOR #2 LIFEBOAT.
Condition: Unknown
Due 21 June 1990
Resolved 21 June 1990
Lifesaving
Issued 21 June 1990
Resolved
RENEW THE EMBARKATION STATION LIGHTS BY THE BOW OF #1 AND #2 LIFEBOAT.
Condition: Unknown
Due 21 June 1990
Resolved 21 June 1990
Lifesaving
Issued 21 June 1990
Resolved
REPAIR THE SPRINKLER SYSTEM ON BOTH LIFEBOATS.
Condition: Unknown
Due 21 June 1990
Resolved 21 June 1990
Lifesaving
Issued 21 June 1990
Resolved
REPAIR ADJUST #2 LIFEBOAT TRANSMISSION LINKAGE.
Condition: Unknown
Due 21 June 1990
Resolved 21 June 1990
Lifesaving
Issued 21 June 1990
Resolved
RENEW THE EXHAUST PENETRATION COLLAR ON #2 LIFEBOAT.
Condition: Unknown
Due 21 June 1990
Resolved 21 June 1990
Lifesaving
Issued 21 June 1990
Resolved
PROCIDE BREATHING AIR BOTTLES ON #1 AND #2 BOATS.
Condition: Unknown
Due 21 June 1990
Resolved 21 June 1990
Fire Fighting
Issued 21 June 1990
Resolved
PROVIDE PROPER MOUNTING BRACKETS FOR FIRE EXTINGUISHERS #13, #38, #43, AND #57.
Condition: Unknown
Due 21 June 1990
Resolved 21 June 1990
Fire Fighting
Issued 21 June 1990
Resolved
REPAIR THE MOUNTING BRACKETS FOR FIRE EXTINGUISHERS #16, #20, #22, AND #81.
Condition: Unknown
Due 21 June 1990
Resolved 21 June 1990
Electrical
Issued 21 June 1990
Resolved
REPACK GLAND PENETRATION FITTING ON WATER MAKER CONTROL PANEL IN ENGINE ROOM.
Condition: Unknown
Due 21 June 1990
Resolved 21 June 1990
Electrical
Issued 21 June 1990
Resolved
REPACK GLAND PENETRATION ON OMNT PURE MSQ UNIT CONTROL PANEL.
Condition: Unknown
Due 21 June 1990
Resolved 21 June 1990
Electrical
Issued 21 June 1990
Resolved
REPLACE WASTED AREAS OF JUNCTION BOXES TO PORT ANCHOR WINDLASS.
Condition: Unknown
Due 21 June 1990
Resolved 21 June 1990
Electrical
Issued 21 June 1990
Resolved
SQUARE AWAY WIRING REMOUNT 2 EA. EXPLOSION PROOF JUNCTIONM BOXES. REHANG WIRES ON PORT FORWARD LEG ON THE TOP OF MOTOR SHED RIG FLOOR.
Condition: Unknown
Due 21 June 1990
Resolved 21 June 1990
Electrical
Issued 21 June 1990
Resolved
MARK PROPERLY TWO BREAKERS ON MAIN SWITCH BOARD SYNCHRONIZING PANEL.
Condition: Unknown
Due 21 June 1990
Resolved 21 June 1990
Electrical
Issued 21 June 1990
Resolved
PROPERLY MARK GEN ALARM BELL IN ENGINE ROOM.
Condition: Unknown
Due 21 June 1990
Resolved 21 June 1990
Electrical
Issued 21 June 1990
Resolved
REPACK ELECTRICAL PENETRATION GLAND FITTINGS TO FUEL OIL CENTRIFUGE IN ENGINE ROOM.
Condition: Unknown
Due 21 June 1990
Resolved 21 June 1990
Fire Fighting
Issued 21 June 1990
Resolved
REPAIR STBD FIRE PUMP. MAINTAIN ONE OF THE PUMPS ON THE MANIFOLD IN THE COMPRESSOR/ AIR RECIEVER ROOM AS A DEDICATED FIRE PUMP UNTIL REPAIRS ARE COMPLETED.
Condition: Unknown
Due 21 June 1990
Resolved 21 June 1990
Fire Fighting
Issued 21 June 1990
Resolved
PLACE THE HELO PAD FIRE BOSS DRYCHEMICAL UNIT BACK IN SERVICE.
Condition: Unknown
Due 21 June 1990
Resolved 21 June 1990
Fire Fighting
Issued 21 June 1990
Resolved
PLACE THE PEDISTLE PAINT LOCKER CO2 FLOODING SYSTEM BACK IN SERVICE.
Condition: Unknown
Due 21 June 1990
Resolved 21 June 1990
Accommodation/Occupational Safety
Issued 21 June 1990
Resolved
PROVIDE ACCESS TO TOP VENT CLOSURE ON PEDISTAL PAINT LOCKER.
Condition: Unknown
Due 21 June 1990
Resolved 21 June 1990
Accommodation/Occupational Safety
Issued 21 June 1990
Resolved
REPAIR BALLAST CONTROL ROOM VENT SUPPLY AND COVER.
Condition: Unknown
Due 21 June 1990
Resolved 21 June 1990
Accommodation/Occupational Safety
Issued 21 June 1990
Resolved
PROVIDE ACCESS TO TOP VENT CLOSURE OF BATTERY ROOM.
Condition: Unknown
Due 21 June 1990
Resolved 21 June 1990
Accommodation/Occupational Safety
Issued 21 June 1990
Resolved
REPAIR VENT CLOSURESW TO EMERGENCY DIESEL GENERATOR ROOM.
Condition: Unknown
Due 21 June 1990
Resolved 21 June 1990
Accommodation/Occupational Safety
Issued 21 June 1990
Resolved
REPAIR PORT THRUSTER ROOM SUPPLY VENT.
Condition: Unknown
Due 21 June 1990
Resolved 21 June 1990
Accommodation/Occupational Safety
Issued 21 June 1990
Resolved
REPAIR QUARTERS AND GALLEY DRY STORES VENT SHUTDOWNS AT LOWER QUARTERS DECK REMOTE STATION AND OUTSIDE MESSROOM.
Condition: Unknown
Due 21 June 1990
Resolved 21 June 1990
Deck/Cargo
Issued 21 June 1990
Resolved
REMOVE THE EXTRANEOUS EQUIPMENT AND SUPPLIES FOR BOTH THE CRANE ENGINE COMPARTMENTS.
Condition: Unknown
Due 21 June 1990
Resolved 21 June 1990
Deck/Cargo
Issued 21 June 1990
Resolved
LABEL THE PULL CABLE CONTROLS IN PORT AND STBD CRANES ENSURING THAT THEY ARE PROPERLY RIGGED AND RUN. ]
Condition: Unknown
Due 21 June 1990
Resolved 21 June 1990
Deck/Cargo
Issued 21 June 1990
Resolved
LABLE THE LEVER CONTROLS IN THE STBD CRANE.
Condition: Unknown
Due 21 June 1990
Resolved 21 June 1990
Deck/Cargo
Issued 21 June 1990
Resolved
REPAIR THE SPLICE IN THE LOUDSPEAKER CABLE ON THE STBD CRANE BOOM.
Condition: Unknown
Due 21 June 1990
Resolved 21 June 1990
Electrical
Issued 21 June 1990
Resolved
PROVIDE BLANKS FOR LIGHTING PANEL, 1013 AND 2ND PANEL AFT(UNMARKED) LOCAT- ED IN PORT MCC ROOM.
Condition: Unknown
Due 21 June 1990
Resolved 21 June 1990
Engineering
Issued 21 June 1990
Resolved
PROVIDE PIPE CAP OR OTHER POSITIVE CLOSURE TO GATE VALVE BENEATH FUEL OIL DAY TANK IN ENGINE ROOM.
Condition: Unknown
Due 21 June 1990
Resolved 21 June 1990
Electrical
Issued 21 June 1990
Resolved
REPAIR ANNUNCIATOR PANEL LIGHTS, LOW OIL TEMP, ENG AIR FILTER #2 EMD, HIGH CRANKCASE PRESSURE LIGHT ON #1 EMD.
Condition: Unknown
Due 21 June 1990
Resolved 21 June 1990
Documentation
Issued 21 June 1990
Resolved
REVISE THE HAZARDOUS LOCATIONS PLAN FOR THE OPERATIONS MANUAL CURRENTLY UNDER REVEIW TO REFLECT A CLASS I DIV II AREA TO THE FULL EXTENT OF THE MUD PIT SHALE SHAKER AREA AND THE MUD PIT ROOM AND AIR RECEIVER/COMPRESSOR ROOMBULKHEADS.
Condition: Unknown
Due 21 June 1990
Resolved 21 June 1990
Deck/Cargo
Issued 21 June 1990
Resolved
INSTALL A LOAD CELL ON THE PORT CRANE.
Condition: Unknown
Due 21 June 1990
Resolved 21 June 1990
Deck/Cargo
Issued 21 June 1990
Resolved
REPAIR TEH TAPERED SECTION OF THE PORTCRANE BOOM. ENSURE PROPER WITNESSED LOAD TESTS ARE CONDUCTED WHEN REPAIRS ARE COMPLETE.
Condition: Unknown
Due 21 June 1990
Resolved 21 June 1990
Navigation
Issued 21 June 1990
Resolved
REPAIR THE OBSTRUCTION LIGHTS SO THAT THEY FLASH IN UNISON.
Condition: Unknown
Due 21 June 1990
Resolved 21 June 1990
Navigation
Issued 21 June 1990
Resolved
REPAIR THE AFT ANCHOR AND STERN LIGHTS.
Condition: Unknown
Due 21 June 1990
Resolved 21 June 1990
Navigation
Issued 21 June 1990
Resolved
REMOVE THE FWD AND AFT MASTHEAD LIGHTS TO COMPLY WITH NON-SELF PROPELLED OPERATIONS.
Condition: Unknown
Due 21 June 1990
Resolved 21 June 1990
Construction/Loadline
Issued 21 June 1990
Resolved
REPAIR THE DOOR FRAME TO THE EMERGENCY GENERATOR ROOM AT THE BOTTOM.
Condition: Unknown
Due 21 June 1990
Resolved 21 June 1990
Construction/Loadline
Issued 21 June 1990
Resolved
REPAIR THE DOOR FRAME AND KNIFE EDGE AT THE BOTTOM OF THE DOOR FRAME TO THETO THE HALIBURTON ROOM.
Condition: Unknown
Due 21 June 1990
Resolved 21 June 1990
Construction/Loadline
Issued 21 June 1990
Resolved
REPAIR THE KNIFE EDGE AT THE BOTTOM OF THE DOOR FRAME TO THE MUD PUMP ROOM.
Condition: Unknown
Due 21 June 1990
Resolved 21 June 1990
Documentation
Issued 21 June 1990
Resolved
PAINT THE LOADLINE PLIMSOL MARKS ON THE PORT AND STBD SIDES OF THE VESSEL.
Condition: Unknown
Due 21 June 1990
Resolved 21 June 1990
Lifesaving
Issued 21 June 1990
Resolved
MARK THE EMERGENCY ESCAPE LADDER LOCATIONS AT THE PORT AFT AND STBD FEED COLUMNS.
Condition: Unknown
Due 21 June 1990
Resolved 21 June 1990
Documentation
Issued 21 June 1990
Resolved
PROVIDE STATION BILLS THROUGHOUT THE VESSEL THAT ARE CONSISTANT AND SHOW THE PROPER NUMBER NAD LOCATION OF LIFERAFTS.
Condition: Unknown
Due 21 June 1990
Resolved 21 June 1990
Construction/Loadline
Issued 21 June 1990
Resolved
RENEW THE GLASS IN THE SIDE PORT TO THE HALIBURTON ROOM STBD SIDE.
Condition: Unknown
Due 21 June 1990
Resolved 21 June 1990
Deck/Cargo
Issued 21 June 1990
Resolved
CLEAN OUT THE FUEL VENT CONTAINMENT BOXES.
Condition: Unknown
Due 21 June 1990
Resolved 21 June 1990
Construction/Loadline
Issued 21 June 1990
Resolved
REPAIR THE MAIN DECK AND ASSOCIATED STRUCTURE AND STIFFNERS BY THE PORT AFTHYDROMATICS
Condition: Unknown
Due 21 June 1990
Resolved 21 June 1990
Electrical
Issued 21 June 1990
Resolved
ADJUST THE GENERAL ALARM BELLS ON THE FWD QUARTER EXTERIOR BULKHEAD AND THE STBD MOON POOL.
Condition: Unknown
Due 21 June 1990
Resolved 21 June 1990
Electrical
Issued 21 June 1990
Resolved
REPAIR THE GENERAL ALARM BELLS BY THE PORT MOON POOL AND EMERGENCY GENERAT-OR ROOM EXTERIOR BULKHEAD BEHIND THE P. TANKS.
Condition: Unknown
Due 21 June 1990
Resolved 21 June 1990
Documentation
Issued 21 June 1990
Resolved
PROVIDE UPDATED CERTIFICATE OF DOCUMENTATION AS " NON-SELFPROPELLED" OR REQUEST INSPECTION AND PROVIDE MANNING AS PER A SELF PROPELLED MODU.
Condition: Unknown
Due 21 June 1990
Resolved 21 June 1990
Engineering
Issued 21 June 1990
Resolved
PROVIDE POSITIVE CLOSURE OR CAP GATE VALVE DRAIN ON FUEL OIL DAY TANK FOR EMERGENCY GENERATOR.
Condition: Unknown
Due 21 June 1990
Resolved 21 June 1990
Construction/Loadline
Issued 21 June 1990
Resolved
PROPERLY MARK ALL REMOTE OPERATED VALVES IN PORT AND STARBOARD PUMP ROOMS.
Condition: Unknown
Due 21 June 1990
Resolved 21 June 1990
Fire Fighting
Issued 21 June 1990
Resolved
REMARK CO2 WARNING ALARM IN PORT PUMP ROOM.
Condition: Unknown
Due 21 June 1990
Resolved 21 June 1990
Construction/Loadline
Issued 21 June 1990
Resolved
PROVIDE GUARD FOR ROTATING SHAFT ON AUTO BILGE PUMP PORT PUMP ROOM.
Condition: Unknown
Due 21 June 1990
Resolved 21 June 1990
Electrical
Issued 21 June 1990
Resolved
PROPERLY MARK GENERAL ALARM BELL STBD PUMP ROOM.
Condition: Unknown
Due 21 June 1990
Resolved 21 June 1990
Construction/Loadline
Issued 21 June 1990
Resolved
PROPERLY INSTALL AUTOMATIC BILGE PUMP STBD PUMP ROOM. COOLING COUNTING IS LOOSE, MOTOR IS MISSING BOLT, TEST PUMPABILITY UPON COMPLETING.
Condition: Unknown
Due 21 June 1990
Resolved 21 June 1990
Construction/Loadline
Issued 21 June 1990
Resolved
REPLACE ALL WASTED BOLTS ON STBD PUMP ROOM LOWER SEA CHEST VALVE (MANUAL) INCLUDING SEA CHEST FLUCH VALVE.
Condition: Unknown
Due 21 June 1990
Resolved 21 June 1990
Construction/Loadline
Issued 21 June 1990
Resolved
REPLACE WASTED BOLT ON AFT RUDDER POST SUPPORT FLANGE STBD SIDE AFTER PUMP ROOM RUDDER COMPARTMENT.
Condition: Unknown
Due 21 June 1990
Resolved 21 June 1990
Navigation
Issued 21 June 1990
Resolved
REPLACE MISSING KEEPERS ON HYDRAULIC RAM TO PAD EYE CONNECTIONS STBD AFT PUMP ROOM RUDDER COMPARTMENT.
Condition: Unknown
Due 21 June 1990
Resolved 21 June 1990
Accommodation/Occupational Safety
Issued 21 June 1990
Resolved
UNCLOG DRAIN TO AFTER STEER COMPARTMENT STBD PUMP ROOM.
Condition: Unknown
Due 21 June 1990
Resolved 21 June 1990
Electrical
Issued 21 June 1990
Resolved
REMOUNT JUNCTION BOX LOCATED STBD AFT CATWALK, STBD PUMP ROOM.
Condition: Unknown
Due 21 June 1990
Resolved 21 June 1990
Accommodation/Occupational Safety
Issued 21 June 1990
Resolved
REPAIR HOLE IN VENT PIPING TO #78 BALLAST TANK STBD PUMP ROOM.
Condition: Unknown
Due 21 June 1990
Resolved 21 June 1990
Construction/Loadline
Issued 21 June 1990
Resolved
REPACK SEALS ON #1 AND#2 BALLAST PUMPS, REPLACE PACKING SUPPORT PLATE ON #2 BALLAST PUMP (BENT).
Condition: Unknown
Due 21 June 1990
Resolved 21 June 1990
Electrical
Issued 21 June 1990
Resolved
REPAIR OPENINGS IN PORT / STBD DRAWWORKS MOTOR JUNCTION BOXES (PURGED) ON RIG FLOOR AND REPLACE WASTED GLAND PENETRATION ON STBD JUNCTION BOX.
Condition: Unknown
Due 21 June 1990
Resolved 21 June 1990
Accommodation/Occupational Safety
Issued 21 June 1990
Resolved
REPAIR HOLES CROP/ RENEW AS NECESSARY SUPPLY PLENUM FOR DRAWWORKS MOTORS PURGE SUPPLY RIG FLOOR.
Condition: Unknown
Due 21 June 1990
Resolved 21 June 1990
Electrical
Issued 21 June 1990
Resolved
REMOUNT EXPLOSION PROOF JUNCTION BOX LOCATED IN OVERHEAD ABOVE BOP CONTROL PANEL RIG FLOOR.
Condition: Unknown
Due 21 June 1990
Resolved 21 June 1990
Electrical
Issued 21 June 1990
Resolved
POUR EYS FITTING ON JUNCTION BOX BEHIND BOP CONTROL PANEL, RIG FLOOR.
Condition: Unknown
Due 21 June 1990
Resolved 21 June 1990
Electrical
Issued 21 June 1990
Resolved
REPLACE WARNING HORN PORT SIDE AFT RIG FLOOR WITH PROPER TYPE APPROVED (UL FM OR CSA) FOR CL I DIV II AREA WITH SEALED FITTINGS.
Condition: Unknown
Due 21 June 1990
Resolved 21 June 1990
Electrical
Issued 21 June 1990
Resolved
REPLACE FOUR MISSING BOLTS ON VENT SHUT DOWN EXPLOSION PSOOF SWITCH BY DRILLERS CONSOLE.
Condition: Unknown
Due 21 June 1990
Resolved 21 June 1990
Electrical
Issued 21 June 1990
Resolved
MOUNT PROPERLY TWO EXPLOSION PROOF JUNCTION BOXES LAYING ON DECK BEHIND MARTIN DECKER CONSOLE.
Condition: Unknown
Due 21 June 1990
Resolved 21 June 1990
Electrical
Issued 21 June 1990
Resolved
PROVIDE EXPLOSION PROOF SWITCH BOX FOR SWACO PUMP STROKE COUNTER OR PURGE IN ACCORDANCE WITH NFPA-496 LOCATED ON RIG FLOOR.
Condition: Unknown
Due 21 June 1990
Resolved 21 June 1990
Electrical
Issued 21 June 1990
Resolved
REMOVE DEAD END WIRING ON EXPLOSION PROOF JUNCTION BOX LOCATED ON PORT FORWARD LEG ON MEZZANINE DECK.
Condition: Unknown
Due 21 June 1990
Resolved 21 June 1990
Electrical
Issued 21 June 1990
Resolved
TIGHTEN EXPLOSION PROOF UNION TO JUNCTION BOX CONNECTION #1 MUD PIT AGITATIOR MOTOR.
Condition: Unknown
Due 21 June 1990
Resolved 21 June 1990
Electrical
Issued 21 June 1990
Resolved
RE-MOUNT EXPLOSION PROOF JUNCTION BOX LOCATED OVER FORWARD SHALE SHAKER.
Condition: Unknown
Due 21 June 1990
Resolved 21 June 1990
Electrical
Issued 21 June 1990
Resolved
PROPERLY INSTALL WIRING TO EXPLOSION PROOF SPEAKER LOCATED IN MUD PITS.
Condition: Unknown
Due 21 June 1990
Resolved 21 June 1990
Accommodation/Occupational Safety
Issued 21 June 1990
Resolved
PROPERLY SUPPRT OVERHEAD RUN OF GALVANIZED PIPING (WATER)L IN MUD PITS.
Condition: Unknown
Due 21 June 1990
Resolved 21 June 1990
Electrical
Issued 21 June 1990
Resolved
REPAIR GENERAL ALARM ROTATING BEACON AFT ENGINE ROOM.
Condition: Unknown
Due 21 June 1990
Resolved 21 June 1990
Electrical
Issued 21 June 1990
Resolved
PROPERLY MARK GENERAL ALARM LIGHT IN COMPRESSOR ROOM.
Condition: Unknown
Due 21 June 1990
Resolved 21 June 1990
Electrical
Issued 21 June 1990
Resolved
READJUST GENERAL ALARM IN MUD PITS, MUD PUMP ROOM, REPAIR INOPERATIVE GEN. ALARM BELLS ON PORT STBD CRANE PEDESTALS LOCATED ON MEZZANINE DECK.
Condition: Unknown
Due 21 June 1990
Resolved 21 June 1990
Electrical
Issued 21 June 1990
Resolved
REPAIR VISUAL AND AUDIBLE LOSS OF PURGE ALARMS TO DRILLERS CONSOLE.
Condition: Unknown
Due 21 June 1990
Resolved 21 June 1990
Electrical
Issued 21 June 1990
Resolved
PROVIDE VISUAL OR AUDIBLE LOSS OF PURGE ALARM TO "ADAIR" GAS DETECTOR PANELON RIG FLOOR IN ACCORDANCE WITH NFPA-496.
Condition: Unknown
Due 21 June 1990
Resolved 21 June 1990
Electrical
Issued 21 June 1990
Resolved
REPAIR LOSS OF PRUGE PRESSURE SWITCH TO SUBSEA MONITOR ON RIG FLOOR.
Condition: Unknown
Due 21 June 1990
Resolved 21 June 1990
Electrical
Issued 21 June 1990
Resolved
PROVIDE PURGE AND LOSS OF PURGE ALARM FOR SWACO PURGE CONTROLLER BOX, SWACOPIT VOLUME TOTALIZER, SWACO BARRIER BOX, ABOVE WORK BENCH ON RIG FLOOR.
Condition: Unknown
Due 21 June 1990
Resolved 21 June 1990
Electrical
Issued 21 June 1990
Resolved
PROVIDE PURGE AND LOSS OF PURGE ALARM FOR SWACO PIT VOLUME INDICATOR ABOVE INDICATOR ABOVE MARTIN DECKER UNIT ON RIG FLOOR, IN ACCORDANCE WITH NFPA496
Condition: Unknown
Due 21 June 1990
Resolved 21 June 1990
Deck/Cargo
Issued 21 June 1990
Resolved
PROVIDE GUARD FOR ENGINE IN DRIVERS COMPARTMENT ON FORKLIFT.
Condition: Unknown
Due 21 June 1990
Resolved 21 June 1990
Lifesaving
Issued 21 June 1990
Resolved
REPAIR THE LIFEBOAT DAVIT CHOCKS ON #1 AND #2 BOAT DAVITS.
Condition: Unknown
Due 21 June 1990
Resolved 21 June 1990
Lifesaving
Issued 21 June 1990
Resolved
PROVIDE A TOTAL OF TWO(2) ORANGE SMOKE FLOATS FOR LIFEBOAT.
Condition: Unknown
Due 21 June 1990
Resolved 21 June 1990
Construction/Loadline
Issued 5 March 1990
Resolved
SUBMIT REPAIR PROPOSAL FOR DAMAGED AREA AT 61 FOOT MARK IN THE PORT BOW COLUMN. PERMANENT REPAIRS TO BE COMPLETED AT TIME OF NEXT RIG MOVE.
Condition: Unknown
Due 5 March 1990
Resolved 5 March 1990
Electrical
Issued 20 July 1989
Resolved
REPAIR THE LOW OIL TEMP. INDICATION LIGHT ON #2 GENERATOR (IMO)
Condition: Unknown
Due 20 July 1989
Resolved 20 July 1989
Electrical
Issued 20 July 1989
Resolved
PROVIDE LOSS OF PURGE ALARM OR REPLACE WITH EXPLOSION PROOF TYPE SWITCH BOXFOR WINCH CONTROL LOCATED ON MEZZANINE DECK NEXT TO RAIL BY MOON POOL.
Condition: Unknown
Due 20 July 1989
Resolved 20 July 1989
Electrical
Issued 20 July 1989
Resolved
POUR 28 EYS FITTINGS ON ELECTRICAL EQUIPMENT AFT OF BOP CONTROL CABINET.
Condition: Unknown
Due 20 July 1989
Resolved 20 July 1989
Fire Fighting
Issued 20 July 1989
Resolved
REPLACE BROKEN CO2 EXTINGUISHER BRACKET LOCATED ADJACENT TO ENTRANCE DOOR AFT DRILL FLOOR.
Condition: Unknown
Due 20 July 1989
Resolved 20 July 1989
Electrical
Issued 20 July 1989
Resolved
PROVIDE WARNING TAGS FOR ALL PURGED EQUIPMENT ON DRILL FLOOR IN ACCORDANCE WITH NFPA 796 (COPY PROVIDED TO RIG).
Condition: Unknown
Due 20 July 1989
Resolved 20 July 1989
Electrical
Issued 20 July 1989
Resolved
ADD PLUG TO EYS ON LIGHT FWD PORT SIDE SHAKER AREA.
Condition: Unknown
Due 20 July 1989
Resolved 20 July 1989
Electrical
Issued 20 July 1989
Resolved
POUR EYS ON EXPLOSION PROOF SWITCH BOX AFT PORT SIDE SHALE SHAKER UNIT.
Condition: Unknown
Due 20 July 1989
Resolved 20 July 1989
Electrical
Issued 20 July 1989
Resolved
REPLACE BOTH EXPLOSION PROOF ARMOURED JUNCTION CABLES ON FORWARD PORT SIDE SHALE SHAKER UNIT.
Condition: Unknown
Due 20 July 1989
Resolved 20 July 1989
Electrical
Issued 20 July 1989
Resolved
REMOVE DEAD ENDED WIRING STBD SIDE SHALE SHAKER AREA MUD PUMP ROOM BULKHEAD
Condition: Unknown
Due 20 July 1989
Resolved 20 July 1989
Electrical
Issued 20 July 1989
Resolved
REPLACE BROKEN EYS FITTING ON JUNCTION BOX TO DE-SANDER/DE-SILTER UNIT.
Condition: Unknown
Due 20 July 1989
Resolved 20 July 1989
Electrical
Issued 20 July 1989
Resolved
RE-MOUNT EXPLOSION PROOF SWITCH BOX PORT SIDE AFT SHALE SHAKER.
Condition: Unknown
Due 20 July 1989
Resolved 20 July 1989
Electrical
Issued 20 July 1989
Resolved
PROVIDE SEALED FITTINGS FOR EXPLOSION PROOF PHONE BOX LOCATED PORT SIDE MEZZANINE DECK BY RAIL TO MOON POOL.
Condition: Unknown
Due 20 July 1989
Resolved 20 July 1989
Electrical
Issued 20 July 1989
Resolved
REPLACE NON-EXPLOSION PROOF SPEAKER HORN WITH EXPLOSION PROOF TYPE (CL I DIV II ANA) PORT SIDE MEZZANINE ON RAIL BY MOON POOL.
Condition: Unknown
Due 20 July 1989
Resolved 20 July 1989
Lifesaving
Issued 20 July 1989
Resolved
ADJUST TRANSMISSION SHIFTING LINKAGE.
Condition: Unknown
Due 20 July 1989
Resolved 20 July 1989
Unknown
Issued 20 July 1989
Resolved
PROVIDE SAFETY BELTS, RIDING BELTS THAT MEET ANSI 10.14 33CFR 142.42.
Condition: Unknown
Due 20 July 1989
Resolved 20 July 1989
Electrical
Issued 20 July 1989
Resolved
RE-MOUNT EXPLOSION PROOF JUNCTION BOX, RIG FLOOR TO GEOLOGRAPH.
Condition: Unknown
Due 20 July 1989
Resolved 20 July 1989
Electrical
Issued 20 July 1989
Resolved
PROVIDE SEALED FITTINGS FOR EXPLOSION PROOF SHUT DOWN SWITCH BOX FOR DRAW WORKS, PORT AND STARBOARD.
Condition: Unknown
Due 20 July 1989
Resolved 20 July 1989
Electrical
Issued 20 July 1989
Resolved
REMOUNT EXPLOSION PROOF SWITCH BOX AND JUNCTION BOX, PORT SIDE AFT DRILL FLOOR.
Condition: Unknown
Due 20 July 1989
Resolved 20 July 1989
Electrical
Issued 20 July 1989
Resolved
REPAIR LOSS OF PURGE ALARM TO DRILLERS CONSOLE, RIG FLOOR.
Condition: Unknown
Due 20 July 1989
Resolved 20 July 1989
Electrical
Issued 20 July 1989
Resolved
PROVIDE FOR INSPECTION MARTIN DECKER ELECTRICAL PANEL ADJACENT TO DRILLERS CONSOLE.
Condition: Unknown
Due 20 July 1989
Resolved 20 July 1989
Fire Fighting
Issued 20 July 1989
Resolved
PROVIDE 2 FIRE SUITS THAT ARE NOT APPOACH SUITS IAW 46CFR 108.497 OR SHOW THAT PERSONNEL HAVE ATTENDED A SCHOOL FOR THERE USE.
Condition: Unknown
Due 20 July 1989
Resolved 20 July 1989
Unknown
Issued 20 July 1989
Resolved
REMOVE HANDS FREE DEVICES FROM ALL FUELING NOZZELS.
Condition: Unknown
Due 20 July 1989
Resolved 20 July 1989
Lifesaving
Issued 20 July 1989
Resolved
RECHARGE THE FORWARD AIR CYLINDER IN THE #2 BOAT.
Condition: Unknown
Due 20 July 1989
Resolved 20 July 1989
Construction/Loadline
Issued 20 July 1989
Resolved
REPAIR THE KING GAUGE FOR PT-6 AND UNPLUG THE SOUNDING TUBE FOR THE #3 STARBOARD TANK.
Condition: Unknown
Due 20 July 1989
Resolved 20 July 1989
Electrical
Issued 20 July 1989
Resolved
INSTALL THE PROPER 1.6 AMP FUSES AS PER THE WIRING DIAGRAM ON THE EMERGENCYSWITCHBOARD.
Condition: Unknown
Due 20 July 1989
Resolved 20 July 1989
Electrical
Issued 20 July 1989
Resolved
SHOW PROPER OPERATION OF THE AUTOMATIC BUS TRANSFER AND AUTOMATIC START SYSTEMS OF EMERGENCY GENERATOR.
Condition: Unknown
Due 20 July 1989
Resolved 20 July 1989
Electrical
Issued 20 July 1989
Resolved
REPAIR OR REMOVE THE CABLE SPLICE ON THE MUD PUMP STROKE COUNTERS.
Condition: Unknown
Due 20 July 1989
Resolved 20 July 1989
Electrical
Issued 20 July 1989
Resolved
PROPERLY PACK THE STUFFING TUBE KICK PIPE ON THE PORT AFT CORNER BY THE ANCHOR WINCH.
Condition: Unknown
Due 20 July 1989
Resolved 20 July 1989
Fire Fighting
Issued 20 July 1989
Resolved
CORRECT THE ENGINE ROOM CO2 OPERATION SIGN IN THE CO2 ROOM. RELABEL THE BOILER ROOM CO2 SYSTEM TO A STORE ROOM CO2 SYSTEM AND LABEL THE INDIVIDUAL PULL BOXES TO AGREE WITH THE OPERATION INSTRUCTIONS.
Condition: Unknown
Due 20 July 1989
Resolved 20 July 1989
Construction/Loadline
Issued 20 July 1989
Resolved
CLOSE THE BULKHEAD ELECTRICAL PENETRATIONS BETWEEN THE MUD PIT/SHALE SHAKERAREA AND THE MOTOR ROOMS AND MUD PUMPROOM.
Condition: Unknown
Due 20 July 1989
Resolved 20 July 1989
Electrical
Issued 20 July 1989
Resolved
RE-ADJUST GENERAL ALARM BELL LOCATED PORT SIDE MOON POOL MAIN DECK LOCATED BY FORWARD DERRICK LEG.
Condition: Unknown
Due 20 July 1989
Resolved 20 July 1989
Documentation
Issued 20 July 1989
Resolved
RE-ADJUST GENERAL ALARM BELL PORT AFT SHALE SHAKER. ADD PLACARD GENERAL ALARM WHEN BELL RINGS GO TO YOUR STATION ADD ADDITIONAL PLACARD TO HALLIBURTON ROOM.
Condition: Unknown
Due 20 July 1989
Resolved 20 July 1989
Electrical
Issued 20 July 1989
Resolved
REPAIR INOPERATIVE GENERAL ALARM BELL IN MUD PUMP ROOM.
Condition: Unknown
Due 20 July 1989
Resolved 20 July 1989
Electrical
Issued 20 July 1989
Resolved
REWIRE BATTERY ROOM TO MEET CL I DIV I GROUP B REQUIRMENTS. REMOVE/RELOCATE3EA LEMARQUE TRICKLE CHARGERS. RELOCATE GENERAL ALARM KNIFE SWITCH AND REMOVE LOCK OUT CAPABILITY.
Condition: Unknown
Due 20 July 1989
Resolved 20 July 1989
Deck/Cargo
Issued 20 July 1989
Resolved
REFASTEN PROTECTIVE GUARDS ON ALL MUD PIT AGITATOR MOTORS.
Condition: Unknown
Due 20 July 1989
Resolved 20 July 1989
Electrical
Issued 20 July 1989
Resolved
REFASTEN GLAND NUT ON EXPLOSION PROOF JUNCTION BOX PORT SIDE AFT SHALE SHAKER AND POUR EYS FITTING.
Condition: Unknown
Due 20 July 1989
Resolved 20 July 1989
Electrical
Issued 20 July 1989
Resolved
REPLACE BROKEN EYS FITTINGS ON LIGHT ABOVE AFT PORT SIDE DESILTER UNIT.
Condition: Unknown
Due 20 July 1989
Resolved 20 July 1989
Fire Fighting
Issued 15 September 1988
Resolved
MAKE PERM REPAIRS TO THE FINE MAIN PIPING LOCATED PORT SIDE BY THE MAIN GENERATOR EXHAUST.
Condition: Unknown
Due 15 September 1988
Resolved 15 September 1988
Construction/Loadline
Issued 2 August 1988
Resolved
COMPLETE REPAIRS TO #4 STARB COLUMN AS DISCUSSED BETWEEN USCG & ABS SURVEYOR. IFF REPAIRS CANT BE MADE OR THE AREA BECOMES WORSE SUBMITT A RE-PAIR PROPOSAL. IF REPAIRS ARE COMPLETED PROVIDE NOT REPORT ATTESTING TO THE SOUNDNESS OF THE WELDING. COMPLIANCE DATE IS: 27AUG88
Condition: Unknown
Due 2 August 1988
Resolved 2 August 1988
Documentation
Issued 2 August 1988
Resolved
PROVIDE MP REPORT. COMPLIANCE DATE IS: 27AUG88
Condition: Unknown
Due 2 August 1988
Resolved 2 August 1988
Documentation
Issued 2 August 1988
Resolved
CONDUCT A FIRE AND ABANDON SHIP DRILL IN THE PRESENCE OF A C.G. INSPECTOR PRIOR TO PUTTING THE VESSEL BACK TO WORK WITH DRILLING CREW. THERE IS NO EXPLIRATION DATE ON THIS REQUIREMENT. THIS IS AN EXTENSION OF NEWMS ITEM #13 (MI88017632) COMPLIANCE DATE IS: 27AUG88
Condition: Unknown
Due 2 August 1988
Resolved 2 August 1988
Deck/Cargo
Issued 2 August 1988
Resolved
PROVIDE GUAGING REPORT FOR THE #2 & 4 BULK MUD TANKS. COMPLIANCE DATE IS: 27AUG88
Condition: Unknown
Due 2 August 1988
Resolved 2 August 1988
Accommodation/Occupational Safety
Issued 23 June 1988
Resolved
PROVIDE RELIEF VALVE FOR THE FORWARD HOT WATER HEATER SET AT NOT MORE THAN 100 PSI & 210 DEGREES FAHRENHEIT. (46 CFR 54.05)
Condition: Unknown
Due 23 June 1988
Resolved 23 June 1988
Unknown
Issued 23 June 1988
Resolved
REPLACE DETERIOATED HEAD BOLTS PORT PUMPROOM SEA CHEST. (46 CFR 56)
Condition: Unknown
Due 23 June 1988
Resolved 23 June 1988
Unknown
Issued 23 June 1988
Resolved
PROVIDE FLAME/HEAT SHIELDS FOR ALL RACO FILLER ON THE EMD'S. (46 CFR 58)
Condition: Unknown
Due 23 June 1988
Resolved 23 June 1988
Accommodation/Occupational Safety
Issued 23 June 1988
Resolved
PROVIDE RELIEF VALVES FOR THE POTABLE AND SANITARY WATER PRESSURE TANKS THAT MEET. (46 CFR 54.15)
Condition: Unknown
Due 23 June 1988
Resolved 23 June 1988
Fire Fighting
Issued 23 June 1988
Resolved
PROVIDE ON BOARD FIREMANS OUTFITS SUITABLE FOR FIRE FIGHTING SERVICE. PRESENT SUITS ON BOARD ARE PROXIMITY TYPE AND NOT SUITABLE FOR USE INTENDED
Condition: Unknown
Due 23 June 1988
Resolved 23 June 1988
Lifesaving
Issued 23 June 1988
Resolved
CONDUCT FIRE AND ABANDON SHIP DRILLS IN THE PRESENCE OF A COAST GUARD INSPECTOR. (46 CFR 107.201)
Condition: Unknown
Due 23 June 1988
Resolved 23 June 1988
Engineering
Issued 23 June 1988
Resolved
MAKE AVAILABLE FOR INTERNAL INSPECTION ALL TENSIONER BOTTLES. (46 CFR 107.201)
Condition: Unknown
Due 23 June 1988
Resolved 23 June 1988
Engineering
Issued 23 June 1988
Resolved
MAKE AVAILABLE FOR INSPECTION ONE(1) RUPTURE DUC. (46 CFR 107.201)
Condition: Unknown
Due 23 June 1988
Resolved 23 June 1988
Unknown
Issued 23 June 1988
Resolved
BENCH TEST ALL RELIEF VALVES FOR THE TENSIONER BOTTLES ENCLUDING THE IN LINE RELIEF VALVE. (46 CFR 107.201)
Condition: Unknown
Due 23 June 1988
Resolved 23 June 1988
Engineering
Issued 23 June 1988
Resolved
BENCH TEST ALL RELEIF VALVES FOR THE RIG AIR AND BULK AIR SYSTEM. (46 CFR 54)
Condition: Unknown
Due 23 June 1988
Resolved 23 June 1988
Unknown
Issued 23 June 1988
Resolved
REPLACE ALL DETERIOATED BOLTS ON THE BULK MATERIAL LINES FOR THE STARBOARD BULK TANK. (46 CFR 58)
Condition: Unknown
Due 23 June 1988
Resolved 23 June 1988
Deck/Cargo
Issued 23 June 1988
Resolved
GAUGE AS REQUIRED THE #2 & 4 BULK TANKS. LOWER SECTION OF THE TANKS SLOW EVIDENCE OF RUST BLISTERS. (46 CFR 54)
Condition: Unknown
Due 23 June 1988
Resolved 23 June 1988
Unknown
Issued 23 June 1988
Resolved
FREE UP THE DOG ON THE #2 BULK TANK MANHOLE DOGS. (46 CFR 54)
Condition: Unknown
Due 23 June 1988
Resolved 23 June 1988
Unknown
Issued 23 June 1988
Resolved
REPLACED DETERIOATED RELIEF VALVE PIPING ON NUMBER 5,6,7,& 8 BULK TANKS. (46 CFR 54)
Condition: Unknown
Due 23 June 1988
Resolved 23 June 1988
Engineering
Issued 23 June 1988
Resolved
MAKE AVAILVBLE FOR INTERNAL INSPECTION ALL RIG AIR AND BULK AIR RECEIVERS. (46 CFR 107.201)
Condition: Unknown
Due 23 June 1988
Resolved 23 June 1988
Construction/Loadline
Issued 27 May 1987
Resolved
LOADLINE MARKINGS ON EACH SIDE OF VESSEL MUST BE CLEARLY VISIBLE. SEE NVIC 4-78 AND 46 CFR 108.663
Condition: Unknown
Due 27 May 1987
Resolved 27 May 1987
Electrical
Issued 27 May 1987
Resolved
PROPERLY SECURE ELECTRIC WIRE RUNS ON THE DRILL FLOOR AND UNDER DRILL FLOOR46 CFR 111.60
Condition: Unknown
Due 27 May 1987
Resolved 27 May 1987
Construction/Loadline
Issued 27 May 1987
Resolved
REPLACE DETERIATED UNDER DECK LONGS LOCATED ABOVE SHELL SHAKER. 46 CFR 108.113
Condition: Unknown
Due 27 May 1987
Resolved 27 May 1987
Deck/Cargo
Issued 27 May 1987
Resolved
INSTALL GUARD ON AIR TUGGER LOCATED ON MAIN DECK AFTER PORT COLUMN, 46 CFR 108.705
Condition: Unknown
Due 27 May 1987
Resolved 27 May 1987
Lifesaving
Issued 27 May 1987
Resolved
ANNUAL LOAD TEST OF HOOK FOR DAVIT LAUNCH RAFTS IS REQUIRED. SEE NVIC 4-78 AND 46 CFR 108.508(A)2
Condition: Unknown
Due 27 May 1987
Resolved 27 May 1987
Fire Fighting
Issued 27 May 1987
Resolved
AT BOTH PRINT LOCKERS, POST INSTRUCTIONS ON USE OF FIXED CO2 SYSTEM. INCLUDE VENT CLOSURE. SEE 46 CFR 108.631(B) AND NVIC 4-78
Condition: Unknown
Due 27 May 1987
Resolved 27 May 1987
Navigation
Issued 27 May 1987
Resolved
DEMONSTRATE PROPER OPERATION OF FOG HORN. SEE NVIC 4-78 AND 33 CFR 67.
Condition: Unknown
Due 31 October 1987
Resolved 18 May 2002
Resolution: MISLE Maintenance - Resolved all open deficiencies issued prior to 6/1/1997 where activity was closed and deficiency due date was past
Accommodation/Occupational Safety
Issued 27 May 1987
Resolved
HOSPITAL SPACE IS REQUIRED TO HAVE TWO TOURNIQUETS. SEE 46 CFR 108.707 AND NVIC 4-78
Condition: Unknown
Due 27 May 1987
Resolved 27 May 1987
Electrical
Issued 27 May 1987
Resolved
SECURE ELECTRIC CABLES OVER DOOR, PORT SIDE FWD. SEE NVIC 4-78
Condition: Unknown
Due 27 May 1987
Resolved 27 May 1987
Deck/Cargo
Issued 27 May 1987
Resolved
REPAIR AIR LEAKS ON MAIN DECK PORTSIDE FWD. SEE NVIC 4-78 (3) D
Condition: Unknown
Due 27 May 1987
Resolved 27 May 1987
Lifesaving
Issued 1 October 1986
Resolved
SUBMIT A MSC (OV MMT) STAMPED APPROVED PRINT FOR THE NEW INSTALLATION OF THE DAVIT LAUNCH LIFE RAFT STATION.
Condition: Unknown
Due 1 October 1986
Resolved 1 October 1986
Fire Fighting
Issued 23 June 1986
Resolved
INSTALL A RELIEF VALVE SET AT 125 PSI AT THE FIRE PUMP DISCHARGE.
Condition: Unknown
Due 23 June 1986
Resolved 23 June 1986
Fire Fighting
Issued 23 June 1986
Resolved
AMEND AND SUBMIT FOR APPROVAL THE FIRE SAFETY CONTROL PLAN BY ADDING FIRE HOSE STATION #27 WHICH IS IN THE SACK STORAGE ROOM.
Condition: Unknown
Due 23 June 1986
Resolved 23 June 1986
Lifesaving
Issued 23 June 1986
Resolved
REMOVE UNAUTHORIZED CANISTER INFLATABLE LIFERAFTS AND EITHER RETURN THE GRANDFATHERED CANISTER INFLATABLE LIFERAFTS OR INSTALL APPROVED DAVIT LAUNCHED LIFERAFTS.
Condition: Unknown
Due 23 June 1986
Resolved 23 June 1986
Electrical
Issued 23 June 1986
Resolved
RECONNECT THE HELIPORT PERIPHERAL LIGHTING.
Condition: Unknown
Due 23 June 1986
Resolved 23 June 1986
Electrical
Issued 23 June 1986
Resolved
RENEW ALL ELECTRICAL FITTINGS IN ALL HAZARDOUS LOCATIONS AND HAVE THEM EXAMINED BY A MARINE INSPECTOR PRIOR TO COMMENCING DRILLING OPERATIONS.
Condition: Unknown
Due 23 June 1986
Resolved 23 June 1986
Engineering
Issued 23 June 1986
Resolved
MAKE THE AUXILIARY BOILERS READY FOR INSPECTION OR REMOVE THEM FROM SERVICEBY DISCONNECTING THE STEAM PIPING, FUEL PIPING, AND ELECTRICAL CONNECTIONS AND BY DRAINING THE FUEL TANK.
Condition: Unknown
Due 23 June 1986
Resolved 23 June 1986
Construction/Loadline
Issued 23 June 1986
Resolved
LABEL ALL THE REMOTE OPERATED VALVES IN BOTH THE PUMP ROOMS.
Condition: Unknown
Due 23 June 1986
Resolved 23 June 1986
Construction/Loadline
Issued 23 June 1986
Resolved
CONNECT ALL VALVE REACH RODS IN BOTH PUMP ROOMS.
Condition: Unknown
Due 23 June 1986
Resolved 23 June 1986
Construction/Loadline
Issued 23 June 1986
Resolved
REPAIR THE #3 PUMP ACTUATOR IN THE STARBOARD PUMP ROOM.
Condition: Unknown
Due 23 June 1986
Resolved 23 June 1986
Lifesaving
Issued 23 June 1986
Resolved
RENEW THE STEERING AND ENGINE THROTTLE CABLES ON THE #2 LIFEBOAT. THE RIG'S MANNING IS LIMITED TO 50 PERSONNEL UNTIL THIS ITEM IS COMPLETED.
Condition: Unknown
Due 23 June 1986
Resolved 23 June 1986
Unknown
Issued 23 June 1986
Resolved
LABEL THE LOCATION OF THE REACH RODS FOR THE FUEL OIL TRANSFER SYSTEM IN BOTH PUMP ROOMS.
Condition: Unknown
Due 23 June 1986
Resolved 23 June 1986
Accommodation/Occupational Safety
Issued 1 May 1986
Resolved
CONDUCT A HYDROSTATIC TEST, OR PROVIDE FOR AN INTERNAL EXAMINATION OF THE RIG AIR AND THREE STARTING AIR RECEIVERS.
Condition: Unknown
Due 1 May 1986
Resolved 1 May 1986
Unknown
Issued 3 February 1986
Resolved
HYDROSTATICALLY TEST ALL FIXED CO2 CYLINDERS
Condition: Unknown
Due 3 February 1986
Resolved 3 February 1986
Lifesaving
Issued 15 January 1985
Resolved
REPLACE ALL BATTERIES IN THE LIFE JACKET LIGHTS WITH APPROVED DATED BATTER-IES.
Condition: Unknown
Due 15 January 1985
Resolved 15 January 1985
Electrical
Issued 15 January 1985
Resolved
LABEL ALL ELECTRICAL SWITCHES AT DRILL FLOOR, THESE REQUIREMENTS ARE TO BE MADE TO THE SATISFACTION OF THE COGNIZANT OCMI AND ATTENDING MARINE INSPEC-TOR NOT LATER THAN 22JAN85 FOR ITEMS 1,4,5,6,; 15FEB85 FOR ITEMS 2,7-11 AND24SEP85 FOR ITEM 3.
Condition: Unknown
Due 15 January 1985
Resolved 15 January 1985
Electrical
Issued 15 January 1985
Resolved
INSTALL BOLTS (5) IN TELEPHONE CONTROL BOX IN MUD PITS WITHIN SEVEN (7) DAYS.
Condition: Unknown
Due 15 January 1985
Resolved 15 January 1985
Electrical
Issued 15 January 1985
Resolved
RE-INSTALL REAR PANELS TO COMMUNICATION EQUIPEMNT CONSULES LOCATED IN WHEELHOUSE WITHIN SEVEN (7) DAYS.
Condition: Unknown
Due 15 January 1985
Resolved 15 January 1985
Unknown
Issued 15 January 1985
Resolved
MAKE SKID PROOF AND REPAINT HELOCOPTER LANDING DECK IN ACCORDANCE WITH 46 CFR 108.235(D) AND 46 CFR 108.241
Condition: Unknown
Due 15 January 1985
Resolved 15 January 1985
Electrical
Issued 15 January 1985
Resolved
HAVE OBSTRUCTION LIGHTS PROFESSIONALLY SERVICED AND RAISED TO WHERE LIGHTS ARE FULLY VISIBLE ABOVE THE HANDRAILS.
Condition: Unknown
Due 15 January 1985
Resolved 15 January 1985
Unknown
Issued 15 January 1985
Resolved
SUBMIT PROPOSAL TO INCREASE HELOCOPTER PAD LANDING NET TO 1.5 METERS WIDE IN ACCORDANCE WITH 46 CFR 108.235(E).
Condition: Unknown
Due 15 January 1985
Resolved 15 January 1985
Fire Fighting
Issued 15 January 1985
Resolved
RESERVICE O2 BOTTLE FOR FIREMAN'S OUTFIT LOCATED IN MOTOR RIG WITHIN SEVEN (7) DAYS.
Condition: Unknown
Due 15 January 1985
Resolved 15 January 1985
Unknown
Issued 15 January 1985
Resolved
REPLACE MISSING BUNK LIGHT COVERS AS NECESSARY IN CREWS QUARTERS WITHIN THIRTY (30) DAYS.
Condition: Unknown
Due 15 January 1985
Resolved 15 January 1985
Accommodation/Occupational Safety
Issued 15 January 1985
Resolved
CONDUCT HYDROSTATIC TEST OR INTERNAL EXAM OF ALL AIR RECEIVERS; 4 RECEIVERS12 GUIDELINE TENSIOMER BOTTLES, AND 7 MOTTOD COMPENSATOR BOTTLES AT NEXT RIG MOVE BUT NO LATER THAN 24SEP85.
Condition: Unknown
Due 15 January 1985
Resolved 15 January 1985
Electrical
Issued 15 January 1985
Resolved
REPAIR OR REPLACE ELECTRICAL WIRE TO OVERHEAD LIGHT ON STBD SIDE FORWARD END OF MUD PITS WITHIN SEVEN (7) DAYS.
Condition: Unknown
Due 15 January 1985
Resolved 15 January 1985
Lifesaving
Issued 11 April 1984
Resolved
REPAIR #1 LIFEBOAT, FIBERGLASS REPAIR WORK NECESSARY.
Condition: Unknown
Due 12 April 1984
Resolved 11 April 1984
Deck/Cargo
Issued 11 April 1984
Resolved
PROVIDE TEST OF RELIEF VALVES FOR AIR RECEIVERS FOR AIR SERVICE ON RIG.
Condition: Unknown
Due 11 April 1984
Resolved 11 April 1984
Fire Fighting
Issued 11 April 1984
Resolved
PROVIDE FOUR 2 1/2"X50 FIRE HOSES.
Condition: Unknown
Due 12 April 1984
Resolved 11 April 1984
Unknown
Issued 20 June 1983
Resolved
MAKE AIR RECEIVERS IN RIG MOTION COMPENSATING SYSTEM AVAILABLE FOR INTERNAL INSPECTION.
Condition: Unknown
Due 20 June 1983
Resolved 20 June 1983
Unknown
Issued 20 June 1983
Resolved
THE FOLLOWING DEFICIENCY PERTAINS TO THE MODU DIAMOND NEW ERA, DN560234
Condition: Unknown
Due 20 June 1983
Resolved 20 June 1983
Fire Fighting
Issued 12 January 1983
Resolved
REPLACE FIRE BOX COVERS NEAR MUD PUMP ROOM AND SCR ROOM.
Condition: Unknown
Due 12 January 1983
Resolved 12 January 1983
Unknown
Issued 12 January 1983
Resolved
(REQUIREMENT 10 CONTINUED) JUNCTION BOXES AT THRUSTER UNIT.
Condition: Unknown
Due 12 January 1983
Resolved 12 January 1983
Lifesaving
Issued 12 January 1983
Resolved
PROVIDE LIGHTS FOR PFD'S IAW 46 CFR 108.514.
Condition: Unknown
Due 12 January 1983
Resolved 12 January 1983
Unknown
Issued 12 January 1983
Resolved
(REQUIREMENT 9 CONTINUED) CONTROLS AND RELIEF VALVES. (46 CFR 53)
Condition: Unknown
Due 12 January 1983
Resolved 12 January 1983
Construction/Loadline
Issued 12 January 1983
Resolved
CORRECT THE FOLLOWING DISCREPANCIES IN PUMP ROOMS; PORT-(A) REPAIR OR RE- PLACE JUNCTION BOX INBOARD OF THRUSTER (B) PROPERLY MOUNT SWITCHBOX AT
Condition: Unknown
Due 12 January 1983
Resolved 12 January 1983
Unknown
Issued 12 January 1983
Resolved
(REQUIREMENT 10 CONTINUED) THRUSTER MOTOR. (C) REMOUNT LIGHT BRACKET NEAR BALLAST PUMP. (D) REPAIR EMERGENCY BILGE SUCTION VALVE REPAIR AIR LINE TO
Condition: Unknown
Due 12 January 1983
Resolved 12 January 1983
Unknown
Issued 12 January 1983
Resolved
(REQUIREMENT 10 CONTINUED) SEA CHEST FLUSHING VALVE; STBD-(A) REPAIR LEAK IN BALLAST PUMP RECIRCULATING VALVE CYLINDER. (B) REPAIR WIRING AND
Condition: Unknown
Due 12 January 1983
Resolved 12 January 1983
Navigation
Issued 12 January 1983
Resolved
MAKE FOG SIGNAL SOUND PROPER SEQUENCE IAW 33 CFR 67.10.
Condition: Unknown
Due 12 January 1983
Resolved 12 January 1983
Documentation
Issued 12 January 1983
Resolved
PROVIDE APPROVED CONSTRUCTION PORTFOLIO ON BOARD RIG IAW 46 CFR 107.305.
Condition: Unknown
Due 12 January 1983
Resolved 12 January 1983
Engineering
Issued 12 January 1983
Resolved
MAKE AUXILIARY THRUSER UNITS AND CONTROLS AVAILABLE FOR TEST.
Condition: Unknown
Due 12 January 1983
Resolved 12 January 1983
Deck/Cargo
Issued 12 January 1983
Resolved
MAKE MUD PUMP RELIEF VALVES AVAILABLE FOR TEST.
Condition: Unknown
Due 12 January 1983
Resolved 12 January 1983
Unknown
Issued 12 January 1983
Resolved
THE FOLLOWING DEFICIENCIES PERTAINS TO THE MODU DIAMOND M NEW ERA, DN560234
Condition: Unknown
Due 12 January 1983
Resolved 12 January 1983
Accommodation/Occupational Safety
Issued 12 January 1983
Resolved
PROVIDE GUARDS ON 2 VENT FANS IN BOILER ROOM.
Condition: Unknown
Due 12 January 1983
Resolved 12 January 1983
Deck/Cargo
Issued 12 January 1983
Resolved
PROVIDE GUARD ON COUPLING ON OILER PUMP UNDER NR2 MUD PUMP.
Condition: Unknown
Due 12 January 1983
Resolved 12 January 1983
Engineering
Issued 12 January 1983
Resolved
REPAIR OVER SPEED TRIP ALARM AND ALARM PANEL RESET ON NR1 EMD.
Condition: Unknown
Due 12 January 1983
Resolved 12 January 1983
Engineering
Issued 12 January 1983
Resolved
REPAIR LUBE OIL ALARM ON NR3 EMD.
Condition: Unknown
Due 12 January 1983
Resolved 12 January 1983
Electrical
Issued 12 January 1983
Resolved
REPAIR GROUND IN A PHASE OF EMERGENCY SWITCHBOARD.
Condition: Unknown
Due 12 January 1983
Resolved 12 January 1983
Electrical
Issued 12 January 1983
Resolved
REPAIR OR REPLACE LIGHT AND WIRING OVER #5 FIRE STATION IN MOON POOL.
Condition: Unknown
Due 12 January 1983
Resolved 12 January 1983
Accommodation/Occupational Safety
Issued 12 January 1983
Resolved
REPLACE BREAKER FOR MACHINERY SPACE REMOTE VENTILATION SHUTDOWN AND MAKE A-VAILABLE FOR TEST 46 CFR 111.80-10.
Condition: Unknown
Due 12 January 1983
Resolved 12 January 1983
Engineering
Issued 12 January 1983
Resolved
REGASKET END COVERS ON #2 BOILER; MAKE #2 BOILER AVAILABLE FOR 1 1/4 TIMES MAWP HYDROSTATIC TEST; MAKE BOTH BOILERS AVAILABLE FOR TEST OF AUTOMATIC
Condition: Unknown
Due 12 January 1983
Resolved 12 January 1983