Records from 1982 to 2009. Most recent: inspection, 15 January 2009.
Inspection history · 44
15 January 2009
Ballast Water Examination · PII Safety Exam · ISPS II Exam
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 3395381
3 March 2006
Re-Inspection · Deficiency Check · Examination of Repairs · Internal Structural Exam · Hull Examination · Cargo Tank Internal
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 2596690
16 February 2006
Security Plan Amendment Review - VSP
Administrative · Marine Safety Center (MSC) · Activity 2586296
18 January 2006
Examination of Repairs
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 2568031
25 March 2005
MTSA/ISPS Verification
Physical examination · MSU LAKE CHARLES · USCG Heartland District (CGD-H) · Activity 2319595
8 March 2005
Deficiency Check
Physical examination · MSU LAKE CHARLES · USCG Heartland District (CGD-H) · Activity 2305703
2 March 2005
COI Inspection · MTSA Verification
Physical examination · MSU LAKE CHARLES · USCG Heartland District (CGD-H) · Activity 2302418
13 May 2004
Re-Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 2066360
10 May 2004
Type not recorded
No type recorded · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 2079080
25 November 2003
Administrative Inspection
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1954326
17 November 2003
Security Plan Review - VSP
Administrative · Marine Safety Center (MSC) · Activity 1950231
14 July 2003
Re-Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 1846091
6 May 2003
Hull Examination
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1787144
30 April 2002
Re-Inspection
Physical examination · MSU LAKE CHARLES · USCG Heartland District (CGD-H) · Activity 1611194
5 July 2001
Administrative
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1068033
4 April 2001
Re-Inspection · Hull Examination
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1467742
9 March 2000
COI Inspection
Physical examination · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1445580
11 October 1999
Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 144399
21 January 1999
Re-Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1395096
21 December 1998
Administrative
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 808705
18 March 1998
COI Inspection · Hull Examination
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1427371
1 January 1998
Administrative
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 783636
18 June 1997
Administrative
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 776460
7 May 1996
Re-Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1412971
19 July 1995
Deficiency Check
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1187951
30 May 1995
COI Inspection
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1430044
25 May 1994
Re-Inspection · Hull Examination
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1429892
23 July 1993
Deficiency Check
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 843265
1 June 1993
COI Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1470365
23 April 1993
Type not recorded
No type recorded · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 116324
27 July 1992
Re-Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1408905
24 March 1992
Deficiency Check
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1353362
28 February 1992
Hull Examination
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1317484
4 June 1991
COI Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 930891
17 December 1990
Type not recorded
No type recorded · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1242915
18 May 1990
Examination of Repairs · Damage Survey · Re-Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 920430
9 June 1989
Hull Examination · Deficiency Check · COI Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 898211
13 February 1989
Hull Examination · COI Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1340372
19 March 1988
Permit to Proceed
Administrative · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1347937
15 March 1985
Type not recorded
No type recorded · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1287803
19 December 1984
Type not recorded
No type recorded · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 977538
9 December 1984
Type not recorded
No type recorded · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 977613
22 August 1984
Type not recorded
No type recorded · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1282567
10 August 1982
Type not recorded
No type recorded · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 968660
Construction/Loadline › Hull › Side Shell
Issued 2 March 2005
Resolved
Examine 6 inch inset portside midship, 3 feet above waterline and repair to the satisfaction of class.
Action required: 705 - Other - as specified
Due 1 April 2005
Resolved 8 March 2005
Resolution: Received ABS annotated 835.
Communications › Alarms/Indicators
Issued 14 July 2003
Resolved
Repair the stbd main engine tachometer in the pilothouse. LEGACY COMPONENT DESC: Rate of Turn Indicator
Action required: 705 - Other - as specified
Due 14 August 2003
Resolved 22 July 2003
Engineering › Diesel Engine (propulsion-reduction gear)
Issued 14 July 2003
Resolved
Properly attach lagging on the main engine exhaust systems. LEGACY COMPONENT DESC: Piping (exhaust)
Action required: 705 - Other - as specified
Due 14 August 2003
Resolved 22 July 2003
Operations/Management › Drills/Instruction
Issued 14 July 2003
Resolved
Provide an emergency broadcast placard. LEGACY COMPONENT DESC: Making Voice Radio Distress Call
Action required: 705 - Other - as specified
Due 14 August 2003
Resolved 22 July 2003
Fire Fighting › Portable CO2 Fire Extinguisher
Issued 14 July 2003
Resolved
Replace the discharge hose and horn on the extinguisher in the engine room, aft. LEGACY COMPONENT DESC: Discharge Hose/Tube
Action required: 17 - Rectify deficiencies prior to departure
Due 14 August 2003
Resolved 22 July 2003
Operations/Management › Drills/Instruction
Issued 14 July 2003
Resolved
Post liferaft placards on bulkhead as opposed to on the rafts. LEGACY COMPONENT DESC: Launching/Recovery of Survival Craft
Action required: 17 - Rectify deficiencies prior to departure
Due 14 August 2003
Resolved 22 July 2003
Communications › Radio Communications
Issued 14 July 2003
Resolved
Install emergency light at the GMDSS station. LEGACY COMPONENT DESC: GMDSS
Action required: 705 - Other - as specified
Due 14 August 2003
Resolved 22 July 2003
Lifesaving › Lifebuoys
Issued 14 July 2003
Resolved
Replace the lifeline on the stbd O2 deck lifebuoy. LEGACY COMPONENT DESC: Buoyant Lifeline
Action required: 17 - Rectify deficiencies prior to departure
Due 14 August 2003
Resolved 22 July 2003
Communications › Internal Communications System
Issued 14 July 2003
Resolved
Provide a sound powered phone for the Engineer's stateroom as per 46 CFR 62.50-20 (f) (2). LEGACY COMPONENT DESC: Sound-powered Telephone
Action required: 17 - Rectify deficiencies prior to departure
Due 14 August 2003
Resolved 22 July 2003
Lifesaving › Lifejacket/PFD (Type I)
Issued 14 July 2003
Resolved
Replace the reflective material on five life jackets. LEGACY COMPONENT DESC: Retroreflective Material
Action required: 17 - Rectify deficiencies prior to departure
Due 14 August 2003
Resolved 22 July 2003
Engineering › Pressure Vessel
Issued 6 May 2003
Resolved
MAKE REPAIRS TO PORT AND STBD #3 P-TANKS AS PER THE N.B.I.C. TO THE SATISFACTION OF AN ATTENDING MARINE INSPECTOR.
Condition: Unknown
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 14 July 2003
Documentation
Issued 30 May 1995
Resolved
OBTAIN ON BOARD A VALID FCC SAFETY RADIO TELEPHONY CERTIFICATE.
Condition: Unknown
Due 30 May 1995
Resolved 30 May 1995
Documentation
Issued 1 June 1993
Resolved
UPDATE OIL TRANSFER PROCEDURES TO COMPLY WITH CURRENT 33 CFR 155.750.
Condition: Unknown
Due 1 June 1993
Resolved 1 June 1993
Lifesaving
Issued 1 June 1993
Resolved
MODIFY THE RESCUE PLATFORM TO ALLOW RECOVERY OF PERSONS FROM THE WATER IN ALL VESSEL DRAFT AND TRIM CONDITIONS.
Condition: Unknown
Due 1 June 1993
Resolved 1 June 1993
Electrical
Issued 17 December 1990
Resolved
RESUBMIT ELECTRICAL PLANS FOR INSTALLATION OF 99 KW GENERATORS AS REQUIRED BY MARINE SAFETY CENTER LETTER SERIAL #E00539 DATED 17OCT90.
Condition: Unknown
Due 17 December 1990
Resolved 17 December 1990
Electrical
Issued 17 December 1990
Resolved
PRESENT VESSEL FOR INSPECTION OF NEWLY INSTALLED GENERATOR TO CHECK FOR COMPLIANCE WITH 46 CFR 111.12 AND 46 CFR 111.30.
Condition: Unknown
Due 17 December 1990
Resolved 17 December 1990
Electrical
Issued 22 August 1984
Resolved
TO PERMANENTLY MOUNT TRANSFORMER TO BULKHEAD IN PORT DECK STOWAGE LOCKER ON MAIN DECK.
Condition: Unknown
Due 22 August 1984
Resolved 22 August 1984
Deck/Cargo
Issued 22 August 1984
Resolved
REMOVE DEADEND CABLE AND REPAIR CONNECTION BOX ON ANCHOR WINDLASS.
Condition: Unknown
Due 22 August 1984
Resolved 22 August 1984
Electrical
Issued 22 August 1984
Resolved
PROVIDE TACHOMETERS FOR AND SATISFACTORILY TEST THE OVERSPEEDS FOR BOTH SHIP'S SERVICE GENERATORS.
Condition: Unknown
Due 22 August 1984
Resolved 22 August 1984
Fire Fighting
Issued 22 August 1984
Resolved
TO REPAIR OR REMOVE FIRE DETECTION SYSTEM.
Condition: Unknown
Due 22 August 1984
Resolved 22 August 1984
Deck/Cargo
Issued 22 August 1984
Resolved
TEST RELIEF VALVES FOR 6 MATERIAL TANKS, POTABLE WATER TANK AND SANITARY WATER TANK.
Condition: Unknown
Due 22 August 1984
Resolved 22 August 1984
Deck/Cargo
Issued 10 August 1982
Resolved
PROVIDE MANUFACTURER NAME PLATE FOR SIX MUD/CEMENT TANKS AND INSTALL SAME.
Condition: Unknown
Due 10 August 1982
Resolved 10 August 1982