DELPHINUS LEADER is a 1998 freight ship. The Coast Guard has recorded 17 inspections since 2016, most recently in March 2025, along with 15 deficiencies and 4 operational controls.
Records from 2016 to 2025. Most recent: inspection, 26 March 2025.
Everything above is free. The detail below — the inspection history, the deficiency record, the operational controls and the documentation record — is Professional, $39 a month. Sign in.
Coast Guard record current through 23 August 2026, retrieved 5 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Ro-Ro Cargo Ship class in Maury's sources begin in 2016.
Every line above is a count of records the US Coast Guard wrote, or a date it recorded.
A blank resolution means none was recorded in this data; it does not establish that a
deficiency is outstanding. Years with a record are calendar years in which a record
exists, not years in service. What Maury does
not do.
Tonnage as PSIX records it57442 - Convention (Subpart B), Gross Ton 17232 - Convention (Subpart B), Net Ton 21514 - Dead Weight, Metric Ton 38874 - Displacement, Metric Ton
This hull's Official Number is not in the NVDC file dated 10 August 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.
Professional
Detail on this page
17 inspections, each with its date, unit and type; 15 deficiencies with the resolution recorded against each; 4 operational controls with the dates imposed and removed; the documentation record, as PSIX holds it. The counts in the summary above are the same
counts, and they are free.
$39 a month or $299 a year, every vessel page, cancel any time.
Founding rate $19.99 a month for life, for the first 200 subscribers.
PlansSign in
Maury does not score, rate or grade vessels, at any price.
Vessel history report
Every record for this hull, in one document — $299
Every recorded inspection, 2016 to
2026 for this class, in one chronology · every deficiency, with system, dates
and resolution · operational controls imposed and removed · every name this
hull has been recorded under · the vessels it was inspected alongside, and when
· how its record compares with hulls of similar age and size, as a fact about the
population and never a judgement about this vessel.
This report is in development and is not for sale yet. There is
no date, and nothing is charged. Leave an email and we will tell you when it exists, once.
Used only to tell you when the report exists.
Not shared, not sold, and not added to a mailing list.
Inspection history · 17
26 March 2025PSC B
Physical examination · Sector Columbia River · USCG Northwest District (CGD-NW) · Activity 8096971
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 15 November 2021Resolved
CO2 level indicator is unreadable due to ice buildup in the low pressure CO2 room
Condition: Improper/Lack of Maintenance
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Resolved 17 November 2021
Resolution: Received class report attesting to the repair of affected equipment. See attached documents for further clarification.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Cargo & other hatchways
Issued 15 November 2021Resolved
Corrosion on electrical components prevented the stern door from being opened and closed properly
Condition: Improper/Lack of Maintenance
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Resolved 17 November 2021
Resolution: Received class report attesting to the temporary repair of affected equipment and class dispensation. See attached documents for further clarification.
01 - Certificates & Documentation › 011 - Ships Certificates › International Air Pollution Certificate (IAPP)
Issued 15 November 2021Resolved
IAPP is incorrectly filled out and does not indicate the presence on an MPEC compliant incinerator onboard although the vessel does possess an IMO Type Approval Letter. This is required for them to be authorized to burn PVC plastics in accoradnce with their Garbage Managment Plan.
Condition: Invalid
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Resolved 17 November 2021
Resolution: Vessel updated garbage plan to include sorting and disposing of PVC plastic waste in lieu of incineration.
07 - Fire Safety › N/A - No Subsystem › Maintenance of Fire protection systems
Issued 11 November 2019Resolved
07124 - Maintenance testing and inspections shall be based on the guidelines developed by the organization. Annual maintenance of the fixed gas fire extinguishing system and portable fire extinguishers was last conducted on Aug 8, 2018, exceeding one year.74SOLAS(14)II-2/14.2.2.1; (MSC.1/CIRC. 1432/7)
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 12 November 2019
Resolved 12 November 2019
Resolution: 12NOV2019 - CLASS REPORT RECIEVED ATTESTING TO THE REQUIRED SHORESIDE MAINTENANCE OF THE FIXED AND PORTABLE FIRE-FIGHTING APPLIANCES.
07 - Fire Safety › N/A - No Subsystem › Oil accumulation in engine room
Issued 9 August 2019Resolved
07126 - Oil fuel & lubricating oil pipelines shall be screened or otherwise protected to avoid oil spray or oil leakages on hot surfaces. Lagging from the exhaust pipe at the cylinder heads #8, 7, 6, 4, 3, 2, & 1 were soaked with oil. Lagging of the base of the turbo is deteriorated. 74SOLAS(97)II-2/15.5.1
Condition: Improper/Lack of Maintenance
Action required: 30 - Ship detained
Resolved 10 August 2019
Resolution: RECEIVED SATISIFACTORY CLASS REPORT. ATTENDING COAST GUARD EXAMINER CONFIRMED.
07199 - The condition of the ship and it's equipment shall be maintained to conform with provisions of the present convention. PSCO observed temporary patch on the #2 hydraulic return line. When the 1st engineer was asked about the patch he stated it was there for chafing protection. PSCO asked to remove the patch to see the condition beneath it and when removed the #2 hydraulic return line started leaking excessive hydraulic fluid from the steering gear.
74SOLAS(14)1/11(a)
Condition: Improper/Lack of Maintenance
Action required: 30 - Ship detained
Resolved 10 August 2019
Resolution: RECEIVED SATISIFACTORY CLASS REPORT ATTESTING TO REPAIRS.
07 - Fire Safety › N/A - No Subsystem › Oil accumulation in engine room
Issued 9 August 2019Resolved
07126 - The condition of the ship and it's equipment shall be maintained to conform with the provisions of the present convention. Fuel leak observed at main engine crankcase and cylinders. Oil soaked rags and open oil filled containers were observed throughout the engine room. SOLAS (14)1/II(c)
Action required: 30 - Ship detained
Due 15 August 2020
Resolved 13 August 2019
Resolution: RECOGNIZED ORGANIZATION SET HARDENED SEALING DEVICE FOR CAM SHAFT FOR MAIN ENGINE AS A CONDITION OF CLASS DUE 15AUG2020.
15 - Safety Management Systems (ISM) › N/A - No Subsystem › Maintenance of the ship and equipment
Issued 9 August 2019Resolved
15109 - The company should ensure that inspections are held at appropriate intervals any non-conformity is reported, appropriate corrective action is taken and records are maintained. PSCO observed, for at least the previous 6 months, the engineering watch has not been logging rounds, documenting known discrepancies or including known discrepancies in the maintenance plan in accordance with their SMS including, but not limited to, the previously identified discrepancies.74SOLAS(14)IX/3.1
Action required: 30 - Ship detained
Resolved 10 August 2019
Resolution: RECOGNIZED ORGANIZATION CONFIRMED ISM TRAINING CONDUCTED BY VESSEL MASTER. SATISFACTORY CLEARED DCEFICIENCY.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Operation of machinery
Issued 9 August 2019Resolved
13108 - The condition of the ship and it's equipment shall be maintained to conform with the provisions of the present Convention. Two hoses were disconnected from the sample point on the oil mist detection system. 74SOLAS(14)1/11(a)
Action required: 17 - Rectify deficiencies prior to departure
Resolved 10 August 2019
Resolution: RECEIVED SATISIFACTORY CLASS REPORT. ATTENDING COAST GUARD EXAMINER CONFIRMED.
02117 - The condition of the ship and it's equipment shall be maintained to conform with the provisions of the present regulation. Observed concrete patch on the CO2 room deck with corrosion. Integrity of deck could not be determined. 74 SOLAS(14)1/11(a)
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 9 October 2019
Resolved 13 August 2019
Resolution: RECOGNIZED ORGANIZATION SET CO2 DECK AS A CONDITION OF CLASS TO BE REPAIRED BY 09OCT2019.
08 - Alarms › N/A - No Subsystem › Other (alarms)
Issued 9 August 2019Resolved
0899 - Where vehicle ramps are installed to give access to spaces below the bulkhead deck, their openings shall be able to be closed to prevent ingress of water below alarmed and indicated to the nav bridge. Water ingress panel on the bridge indicated the rear ramp was closed when it was open. The switch is heavily corroded and had to be manually pulled to display proper orientation on the ingress panel. Additionally the local panel for the rear ramp indicator panel lamp close light is inoperable. 74SOLAS(04)II-2/20.21.2
Action required: 17 - Rectify deficiencies prior to departure
Resolved 10 August 2019
Resolution: RECEIVED SATISIFACTORY CLASS REPORT ATTESTING TO REPAIRS OF INDICATOR SWITCH FOR STERN LAMP AND LIGHT BULB REPAIRS FOR INDICATOR PANEL.
09 - Working and Living Conditions › 092 - Working Conditions › Lighting (Working spaces)
Issued 9 August 2019Resolved
09203 - All electrical auxiliary services necessary for maintaining the ship in normal operational and habitable conditions is ensured. PSCO observed multiple light fixtures throughout the ship were damaged and deteriorated, not providing adequate protection for the electrical source. 74SOLAS(04)II-1/40.1.1
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 10 August 2019
Resolution: RECEIVED SATISIFACTORY CLASS REPORT ATTESTING TO REPAIRS OF LIGHTING FIXTURES.
11 - Life Saving Appliances › N/A - No Subsystem › Launching arrangements for survival craft
Issued 9 August 2019Resolved
11112 - Each life raft shall be stored with a float free arrangement. PSCO observed the painter line on the port & stbd life rafts tied directly to the ship. 74SOLAS(14)III/13.4.2
Action required: 10 - Deficiency Rectified
Resolved 9 August 2019
Resolution: HYDROSTATIC RELEASE UNITS WERE CORRECTED ON THE SPOT BY SHIPS CREW.
Fire Fighting › Fixed Fire Detection System › Heat Detectors
Issued 29 September 2017Resolved
Fire protection systems shall be kept in good working order so as to ensure their required performace if a fire occures, including fire detection systems. Vessel was unable to demonstrate satisfactory testing of fixed smoke or heat detection nor produce record of monthly testing for previous month since drydock in July/August 2017. SOLAS74(2014Con)II-2/2.1.1.2 - 10(c)
Condition: Invalid
Action required: 705 - Other - as specified
Due 29 September 2017
Resolved 29 September 2017
Resolution: Witnessed satisfactory testing of heat/smoke detection in multiple spaces and witnessed alarm on bridge Fire Detection Panel.
Issued LOD for inoperable depth sounder. Proof of repairs must be submitted to the COTP zone prior to return to the US after sailing foreign.
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Resolved 16 June 2016
Resolution: Received tech report attesting to the repair of the vessel's echo depth sounder.